3. Characteristics
Type 2/2 solenoid cartridge valve
Design two stage, seat type with flow checked from A ⇒ B
Mounting method screw−in cartridge
Size nom. 10 mm, BUCHER cavity type DD,
with adapter ring C: BUCHER cavity type DC
Mass kg 0,50
Mounting attitude unrestricted
Flow direction A ⇒ B / B ⇒ A, see symbols
Operating pressure bar to 350 in A and B
Flow rate Qmax l/min 140
Fluids Hydraulic oils HL and HLP to DIN 51 524,
other fluids − contact BUCHER
Fluid temperature range _C −25 ... + 80
Ambient temperature _C −25 ... + 50
Viscosity range cSt 10 ... 500, recommended 15 ... 250
Minimum fluid cleanless 18/14 to ISO 4406 /CETOP RP70H 8 ... 9 to NAS 1638
Standard voltages VAC 115, 230 50 ... 60 Hz
VDC 12, 24
Nom. voltage tolerance % $10
Nom. power consumption VAC 17W (Option: 25 W)
VDC 17W (Option: 27 W)
Duty cycle % 100
Enclosure protection IP 65 to DIN 40050
Electrical connection 3−pin square plug to DIN 43 650 / ISO 4400 (standard),
other connectors − contact BUCHER
8 energised
→ ∆p (bar)
8
D
6 energised
6
4 4 A⇒B
2 2 energised
10 20 30 40 50 60 70 80 90 100 120 140 10 20 30 40 50 60 70 80 90 100 120 140
→ Q (l/min) → Q (l/min)
B⇒A
→ ∆p (bar)
8 deenergised 6
de−
D
6 4 energised
4 B⇒A 2 A⇒B
2 deenergised deenergised
Performance limits
None within the
range
p = 350 (bar)
Q = 140 (l/min)
400−P−131120−E−/07.02 2/4
5. Dimensions
Manual override ø 30
2,5
on type WR22O..10 only
Clearance to remove plug
12
10
PG 9
ø 36
58
53
81
Model
code
128,5
131
WRA22...
18
6. Schematic section
4 Seat kit no. DS−276, comprising:
Itm. Qty. Description Size
1 1 Seal ∅ 22,1 / 16,5 x 2,5
2 1 O−ring no 117 ∅ 20,29 x 2,62 N90
3 1 O−ring no 020 ∅ 21,95 x 1,78 N90
4 2 O−ring ∅ 16,00 x 2,00 Viton
4 WRA22GE..A−10 5 1 O−ring ∅ 27,00 x 1,5 N75
WRA22GN..A−10
3
2 5
B B
1
A
A
4 WRA22OE..A−10
WRA22ON..A−10
3
2
B 5
B
1
A
A
400−P−131120−E−/07.02 3/4
7. Installation and servicing
All installation and servicing must be the new seals must be thoroughly oiled the specified tightening torque when fit-
carried out with care, and by qualified or greased before they are fitted. Use ting the cartridge.
personnel only. When changing seals,
400−P−131120−E−/07.02 4/4