REPORT NO: GTCL/LIBRA/BKB800MMSCFD/RT-0016 CLIENT: GAS TRANSMISSION COMPANY LTD

Test Date: 12-Feb-21 RADIOGRAPHIC Project: Bakhrabad 800 MMSCFD MS


Iso. Drawg. No: Location: Bakhrabad, Cumilla
EXAMINATION REPORT
Item No: Requested by: M/S Libra Enterprise
Technique Description Equipment and Material
Exposure Radiation Source Ir.192
√ SWSI DWSI DWDI Source Strength 24.15 Ci
SFD: 18" Source Size/Focal Spot 3.2 mm
IQI Type √ Wire Hole IQI 6 FE EN
Sensitivity: ≤2% Density: 2.0-4.0 Film Brand and Designation Fuji IX 100 HD
Film Processing: Manual Welding Process: SMAW Lead Screens: 0.005” Thick
Test Procedure IITS/RT/007, Rev. C Acceptance Criteria ASME B31.8
Weld Dia. X Welder Area of Result
S/N Interpretation Comments
Identification Thick. ID Interest (cm) IITS GTCL
180344HP04-01 Ø36 X 31.8 L-23/27
01 0-290 Po Acc.
SP-125, J # S09 mm R-25/28
180344HP04-01 Ø36 X 31.8 L-23/27
02 0-290 Po, SL Acc.
SP-125, J # S11 mm R-25/28
180344HP04-01 Ø36 X 31.8 L-23/27
03 0-290 CP Acc.
SP-125, J # S13 mm R-25/28
180344HP04-01 Ø36 X 31.8 L-23/27
04 0-290 CP, Po Acc.
SP-125, J # S15 mm R-25/28
180344HP04-02 Ø36 X 31.8 L-23
05 0-290 Po Acc.
SP-126, J # S01 mm R-25/27
180344HP04-02 Ø36 X 31.8 L-23
06 0-290 SL, Po Acc.
SP-126, J # S02 mm R-25/27
180344HP04-02 Ø36 X 31.8 L-23/27
07 0-290 CP, Po Acc.
SP-126, J # S04 mm R-25/27
180344HP04-02 Ø36 X 31.8 L-23/27
08 0-290 CP Acc.
SP-126, J # S05 mm R-25/28
180344HP04-02 Ø36 X 31.8 L-23/27
09 0-290 SL, Po Acc.
SP-126, J # S07 mm R-25/28
= = = = = = = = =
IP. Inadequate Penetration Cr. Crack HB. Hollow Bead BT. Burn Through
LOF. Lack of Fusion EU External Under Cut CP. Cluster porosity EP. Excessive Penetration
SI. Slag Inclusion H/L High low TI. Tungsten Inclusion NSD. No Significant Discontinuity
Po. Porosity RS. Re Shoot CL. Cold lap Acc. Accept
RC .Root Concavity SL. Slag Line IU. Internal undercut Rej. Reject

FOR IITS FOR LIBRA FOR SUNNEX FOR GTCL


Jahid/Kabbo/Rony

13-Feb-2021