Sie sind auf Seite 1von 14

Project Name: ROTANA HOTEL

Project Number: FJ1610


Designer: Zaid Abu-Rahma
C:\Users\HP\Desktop\ROTANA\B1.rpf

RAPT - Version: 6.2.1.8


Reinforced And Post-Tensioned Concrete Analysis & Design Package
Copyright(C) 1988 - 2009 PCDC Pty. Ltd. All Rights Reserved

Licensee
Freyssinet Gulf LLC
P. O. Box 36211
Dubai U. A. E.
29846110705UPP

Input
General
Design Code List United Kingdom - BS 8110*SAVED*
Material List United Kingdom - United Kingdom Materials*SAVED*
Reinforcement Type List Bonded Post-Tensioned
Member Type List Beam
Panel Type List Internal
Strip Type List One way - Nominal Width
Column Stiffness List Equivalent Column
Concrete - Spanning Members List 40MPa
Concrete - Columns List 40MPa
Top Reinforcement Cover mm 32
Bottom Reinforcement Cover mm 32
Self Weight Definition List Program Calculated
Pattern Live Load Y/N
Earthquake Design List None
Moment Redistribution % 0
Design Surface Levels List Extreme Surfaces

Span
Span Span Slab Panel Panel
Length Depth Width Width
Left Right
mm mm mm mm
LE 0
1 14700 350 4500 4500
RE 0

Columns
Column Column Support Column Column Column Column Column Column Transverse Capital Depth Pin Percentage Braced Column Punching
Grid Type Height Width Length Height Width Length Column below Base Column frame Shortening Shear
Reference Above Above Above below below below spacing deepest below Stiffness at this Restrained Check
section column required
A List mm mm mm mm mm mm mm mm Y/N % Y/N Y/N Y/N
1 1 Column 0 0 0 2300 1000 400 4500 0 Y 85 Y N Y
2 2 Column 2300 1000 800 2300 1000 800 4500 0 Y 85 Y N Y

Column Transverse Transverse


effective v'c
depth
difference
mm MPa
1 0 0
2 0 0

Beams
Beam Beam Beam Beam Effective
Number Depth Width Width Flange
at Width
Slab
mm mm mm mm
1 1000 1000 1000 1000
RAPT 6.2.1.8 Project Name: ROTANA HOTEL Page 2/14
Licensee: Freyssinet Gulf LLC 10/01/2011 11:31:32 License No.: 29846110705UPP
Load Cases
Load Load Type Load Definition Live Load Description
Case Deflection
Case
List List Y/N A
1 Self Weight Applied Loads
2 Extra Dead Load Applied Loads
3 Live Load Applied Loads Y

1. Self Weight - Line


Load Left End Left end of Load at Right End Right end of Load at Description
Reference load from left end reference load from right
Column reference column reference end
column column
mm kN/m mm kN/m A
1 1 0 53.39 2 0 53.39

2. Extra Dead Load - Line


Load Left End Left end of Load Right End Right end of Load Description
Reference load from at left reference load from at right
Column reference end column reference end
column column
mm kN/m mm kN/m A
1 1 0 25 2 0 25

3. Live Load - Line


Load Left End Left end of Load Right End Right end of Load Live Load Description
Reference load from at left reference load from at right reduction
Column reference end column reference end
column column
mm kN/m mm kN/m #.# A
1 1 0 25 2 0 25 1

Load Combinations : Ultimate


Load Description Prestress Prestress 1. Self 2. Extra 3.
Combination Secondary Secondary Weight Dead Live
Adverse Beneficial Load Load
A #.# #.# #.# #.# #.#
1 Live Load 1 1 1.4 1.4 1.6
2 Live Load 1 1 1 1 1.6
3 Dead Load 1 1 1.5 1.5 0

Load Combinations : Short Term Service


Load Description Long-term 1. Self 2. Extra 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Live Load 1 1 1 1

Load Combinations : Permanent Service


Load Description Long-term 1. Self 2. Extra 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Live Load 1 1 1 0.25

Load Combinations : Deflection


Load Description Long-term 1. Self 2. Extra 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Short Term - Deflection 1 1 1 1
2 Permanent - Deflection 1 1 1 0.25
3 Initial - Deflection 1 1 0 0
RAPT 6.2.1.8 Project Name: ROTANA HOTEL Page 3/14
Licensee: Freyssinet Gulf LLC 10/01/2011 11:31:34 License No.: 29846110705UPP
Load Combinations : Transfer Prestress
Load Description Transfer 1. Self 2. Extra 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Transfer 1 1 0 0

Load Combinations : Pre Existing


Load Description Long-term 1. Self 2. Extra 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Pre Existing 1 1 0 0

Load Combinations : Construction


Load Description Long-term 1. Self 2. Extra 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Construction 1 1 0 0

Load Case 1 : 1. Self Weight

1 2
kN/m
60 L1
40
20
0
0 14700mm

Load Case 2 : 2. Extra Dead Load

1 2
kN/m
60
40
L1
20
0
0 14700mm

Load Case 3 : 3. Live Load

1 2
kN/m
60
40
L1
20
0
0 14700mm
Prestress
Tendon Normal or Steel Steel Prestress Prestress Number Number Spacing Top Bottom Left Distance to Left Right
upside down Type Diameter Type Anchorage of of of Cover Cover Anchorage left Anchorage Anchorage
profiles Size Strands Tendons tendons to to Duct Reference anchorage Type Reference
Duct Column from column Column
List List List List List List #.# mm mm mm mm List
1 Strand 15.7mm MultiStrand 13 13 1 55 70 1 1500 2
2 Strand 15.7mm MultiStrand 13 13 1 55 70 1 0 1

Tendon Distance to Right Stacked tendons, Tendon


Right Anchorage No effect on Length
Anchorage from Type effective shear
Column width
mm List List mm
1 0 Individual 13200
2 13200 Individual 13200

Tendon 1 : - Drape Locations


Span Tendon Length of Left End Length of Right End Reverse Number of Extra Tendon Number of
Profile Type Straight Straight Curve strands from angle Profile strands
Section/Start of Section/End of Radius left end change Point full length
Drape Section in Drape Section in terminating in this Spacing of tendon
Span Span in span span in span
List mm mm mm # #.# mm #
1 1500 0 5530 0 0 1000 13
RAPT 6.2.1.8 Project Name: ROTANA HOTEL Page 4/14
Licensee: Freyssinet Gulf LLC 10/01/2011 11:31:36 License No.: 29846110705UPP
Tendon 1 : - Allowable Profiles
Span Tendon Cover Tendon Cover to Tendon Cover Available Relative
to centreline at duct at low point to duct at right Parabola Minimum
left end of span of parabola end of span Drape Tendon
Ratio
mm mm mm mm #.#
1 209.6 70 629.6 453 1

Tendon 1 : - Adopted Profiles


Span Profile Profile Profile Profile Adopted Percentage of Prestress Balanced
Height height at Height at height at Parabolic available Force Uniform
Datum left end midpoint of right end Drape parabolic drape Load
of span parabola of span adopted
mm mm mm mm mm % kN %
1 1000 920 170.9 327.9 453.1 100 157.75 79.9

Tendon 1 : - Details
Reverse Curve at Left Anchorage Y/N N
Reverse Curve at Right Anchorage Y/N N
Percentage Jacking Force % 80

Tendon 1 : - Jacking Sequence


Stage Proportion of Stressing Concrete
Jacking force Time in Strength
applied at this days
stage
% #.# MPa
25 0.577 9
75 3.376 25
0 0 0
0 0 0

Tendon 2 : - Drape Locations


Span Tendon Length of Left End Length of Right End Reverse Number of Extra Tendon Number of
Profile Type Straight Straight Curve strands angle Profile strands
Section/Start of Section/End of Radius from right change Point full length
Drape Section in Drape Section in terminating in this Spacing of tendon
Span Span in span span in span
List mm mm mm # #.# mm #
1 0 1500 5530 0 0 1000 13

Tendon 2 : - Allowable Profiles


Span Tendon Cover Tendon Cover to Tendon Cover Available Relative
to centreline at duct at low point to duct at right Parabola Minimum
left end of span of parabola end of span Drape Tendon
Ratio
mm mm mm mm #.#
1 629.6 70 209.6 453 1

Tendon 2 : - Adopted Profiles


Span Profile Profile Profile Profile Adopted Percentage of Prestress Balanced
Height height at Height at height at Parabolic available Force Uniform
Datum left end midpoint of right end Drape parabolic drape Load
of span parabola of span adopted
mm mm mm mm mm % kN %
1 1000 327.9 170.9 920 453.1 100 157.75 79.9

Tendon 2 : - Details
Reverse Curve at Left Anchorage Y/N N
Reverse Curve at Right Anchorage Y/N N
Percentage Jacking Force % 80

Tendon 2 : - Jacking Sequence


Stage Proportion of Stressing Concrete
Jacking force Time in Strength
applied at this days
stage
% #.# MPa
25 0.577 9
75 3.376 25
RAPT 6.2.1.8 Project Name: ROTANA HOTEL Page 5/14
Licensee: Freyssinet Gulf LLC 10/01/2011 11:31:39 License No.: 29846110705UPP

Stage Proportion of Stressing Concrete


Jacking force Time in Strength
applied at this days
stage
% #.# MPa
0 0 0
0 0 0

Tendon 1 : - Gross Extension: 82.4mm - 1 - 13/15.7


Profile Heights
Span 1 Locat mm 1500 2442.9 3385.7 4328.6 5271.4 6214.3 7157.1 8100 9042.9 9985.7 10928.6 11871.4 12814.3 13757.1 14700
Height mm 920 710 565 440 330 240 170 115 85 70 75 100 145 205 330

Critical Profile Points


Span 1 Locat mm 1500 10204.2 14700
Height mm -122.5 -930 -714.6

Tendon 2 : - Gross Extension: 82.4mm - 1 - 13/15.7


Profile Heights
Span 1 Locat mm 0 942.9 1885.7 2828.6 3771.4 4714.3 5657.1 6600 7542.9 8485.7 9428.6 10371.4 11314.3 12257.1 13200
Height mm 330 205 145 100 75 70 85 115 170 240 330 440 565 710 920

Critical Profile Points


Span 1 Locat mm 0 4495.8 13200
Height mm -714.6 -930 -122.5

Tendon 1 : - 1 - 13/15.7
mm
0
13

13
-300

-600
13

13
-900
920cl

330cl
1 2
710

565

440

330

240

170

115

100

145

205
85

70

75

Tendon 2 : - 1 - 13/15.7
mm
0
13

13

-300

-600
13

13

-900
330cl

920cl

1 2
205

145

100

115

170

240

330

440

565

710
75

70

85

Reinforcement
Reinforcement Reinforcement Preferred Number
Use Type Bar Size of Legs
List List #
Flexural Bar T 460MPa
Flexural Mesh A 460MPa
Shear Option 1 T 460MPa 8 2
Shear Option 2 T 460MPa 10 2
Shear Option 3 T 460MPa 12 2
Punching Shear T 460MPa 10 2
RAPT 6.2.1.8 Project Name: ROTANA HOTEL Page 6/14
Licensee: Freyssinet Gulf LLC 10/01/2011 11:31:41 License No.: 29846110705UPP
Reinforcement
Maximum Minimum Minimum Minimum Span Minimum Span Infill Stagger
Bar Bar Continuous Reinforcement Reinforcement Bars Bars
Spacing Spacing Reinforcement into End into Internal
Support Support
mm mm #.# #.# #.# Y/N Y/N
Support Reinforcement 300 60 0 N N
Span Reinforcement 300 60 0 0 N N

Design Zones : Top


Layer Steel Left End Distance to Bar stagger Top Cover Right End Distance to Bar stagger Top Cover Maximum Minimum Preferred Minimum
Number type Reference left end of length at left at left end Reference right end of length at at Right Bar Size Bar Size bar size Number of
Column bar end Column bar right end end Bars
List mm mm mm mm mm mm List List List #
1 Bar 1 0 0 32 2 0 0 32 32 16 25 0

Layer Maximum Minimum % in


Number Spacing of Steel area as Flange
Bars %
mm % %
1 0 0 0

Design Zones : Bottom


Layer Steel Left End Distance to Bar stagger Bottom Right End Distance to Bar stagger Bottom Maximum Minimum Preferred Minimum
Number type Reference left end of length at left Cover at left Reference right end of length at Cover at Bar Size Bar Size bar size Number of
Column bar end end Column bar right end Right End Bars
List mm mm mm mm mm mm List List List #
1 Bar 1 0 0 32 2 0 0 32 32 16 25 0

Layer Maximum Minimum % in


Number Spacing of Steel area as Flange
Bars %
mm % %
1 0 0 0

Reinforcement Design Zones

1 2
mm
0

-200

-400

-600

-800

-1000
0 14700mm
Design Data
Capacity Reduction factor (phi) for Flexure #.# 1
Capacity Reduction factor (phi) for Shear #.# 1
Material Factor for Concrete in Flexure #.# 1.5
Material Factor for Concrete in Shear #.# 1.25
Material Factor for Reinforcement #.# 1.05
Maximum Ratio of Neutral Axis Depth for Ductility #.# 0.5
Ductility Check at Left End Column Y/N Y
Ductility Check at Right End Column Y/N Y
Minimum Reinforcement Strength Limit - #.## x M* #.# 0
Flexural Critical Section - Consider Transverse Beams Y/N Y
Flexural Critical Section - Distance from centre of Support #.# -1
Beam Left Sideface Cover (Internal) mm 25
Beam Right Sideface cover mm 40
Prestress Minimum Reinforcement Basis List Program Default
Shear Enhancement at Supports Y/N Y
Ast Value in Shear Calculations List Calculated
AS3600 Shear Fitment Hooks Located at List Top of Fitment
Moment Diagram Offset For Flexure Calculations List Code Default
Limit Reinforcement Strain Y/N N

Maximum Service Stress Change - Prestressed Sections MPa 200


Maximum Service Stress Change - Reinforced Sections MPa 0
Relative Humidity % 50
Average Temperature C. 20
RAPT 6.2.1.8 Project Name: ROTANA HOTEL Page 7/14
Licensee: Freyssinet Gulf LLC 10/01/2011 11:31:44 License No.: 29846110705UPP

Prestress Losses Calculations based on List Program Default


Crack Width Calculations List Code default
AS3600 Shrinkage and Temperature Reinforcement List Moderate
Degree of Restraint in Primary Direction % 0
Degree of Restraint in Secondary Direction % 0
Concrete Strength Gain Rate List N

Concrete Tensile Strength for Deflection Calculations- #.## x (Fc)n #.# -1


Maximum Value of Ieff/Igross for Deflection Calculations #.# 0.6
Total Deflection Warning Limit - Maximum Span/Deflection #.# 250
Total Deflection Warning Limit - Maximum Deflection mm 56
Incremental Deflection Warning Limit - Maximum Span/Deflection #.# 500
Incremental Deflection Warning Limit - Maximum Deflection mm 20
Time of Loading in days #.# 10
Age Adjustment Factor #.# 0.76
Concrete Strength at Time of Loading MPa 32
Loaded Period in years #.# 30
Tension stiffening Approach List Modified Concrete Tensile Modulus Method

Live Load Pattern Factor #.#


Pattern Live Load for Ultimate Strength Y/N
Pattern Live Load for Crack Control Y/N
Pattern Live Load For Deflections Y/N
Pattern Live Load for Deflection Permanent Load Combination Y/N

Material Properties
Concrete
Description 40MPa
Characteristic Compressive Strength 40
Mean Compressive Strength 46.53
Lower Characteristic Tensile Strength 3.16
Upper Characteristic Tensile Strength 5.06
Concrete Weight 2447
Design Concrete Modulus 28000
Mean Concrete Modulus 29305
Ultimate Concrete Modulus 28401.9
Basic Shrinkage Strain 600
Basic Creep Factor 3.4
Concrete Strain Limit 0.004

Prestress Strand
Diameter Area Breaking 0.2% 1% Breaking Design Elastic Plastic Basic Weight Material Material Material Material Capacity
Load Proof Stress Strain Strain Modulus Modulus Relaxation Factor Factor Capacity Reduction Factor
Stress Limit Flexure Shear Reduction - Shear
Factor - Flexure
15.7 150 265 85 87.5 0.06 90 1.95e5 2200 2 1.18 -1 -1 -1 -1

Include as Set as Description


Flexural default
Reinforcement
for Shear
Y N 15.7 Super

Bonded Multistrand
Anchorage Description Transfer Anchor Draw-in Maximum Set as
Size Concrete Friction Jacking default
Strength Force
13 30 2 6 80 N

Live Deformed Nominal Full


End Strand Dead Swaged Dead Swaged
End End Dead End
Ineffective Length mm 100 100 100 100
Force at Start of Transition % 100 40 50 100
Transition Length mm 0 1000 500 0
Force at End of Transition % 100 100 100 100

Number Duct Duct Wall Centroid Duct Wobble - Minimum


of Diameter Thickness Distance Friction Unintentional Reverse
Cables Friction - K Curve Radius
# mm mm mm #.# 1/m mm
13 85 3 11.2 0.2 0.003 5530
RAPT 6.2.1.8 Project Name: ROTANA HOTEL Page 8/14
Licensee: Freyssinet Gulf LLC 10/01/2011 11:31:46 License No.: 29846110705UPP
Reinforcement Bar
Designation Type Yield Elastic Ductility Peak Peak Design Material Material Material Material Capacity Include as Description
Stress Modulus Strain Stress Strain Factor Factor Capacity Reduction Factor Flexural
Limit Flexure Shear Reduction - Shear Reinforcement
Factor - Flexure for Shear
T Deformed 460 2e5 0.05 496.8 90 -1 -1 -1 -1 Y

Nominal Bar Bar Bar Bar Stock


Bar Size Diameter Area Inertia Weight Length
A mm mm2 mm4 kg/m mm
8 8 50.3 201.14 0.4 12000
10 10 78.5 491.07 0.62 12000
12 12 113 1018.29 0.89 12000
16 16 201 3218.29 1.58 12000
20 20 314 7857.14 2.47 12000
25 25 491 19182.5 3.85 12000
32 32 804 51492.6 6.31 12000
40 40 1260 1.257e5 9.86 12000

Elevation view

1 2
mm
0

-200

-400

-600

-800

-1000
0 14700mm

Plan view

1 2
mm
-2000

-1000

1000

2000
0 14700mm

Full Elevation View

1 2
mm
2000

1000

-1000

-2000
0 14700mm
Warnings
Input
Warning:At 1500mm from the left end of this span, this tendon duct either violates nominated top cover or is outside the concrete section in this span.

Output
Warning:SUPPORT Reinforcing Bar Spacing There have been problems in determining a bar size to satisfy the design spacing requirements. See
Detailed Reinforcement Design Comments.
Warning:SPAN Reinforcing Bar spacing There have been problems in determining a bar size to satisfy the design spacing requirements. See Detailed
Reinforcement Design Comments.
RAPT 6.2.1.8 Project Name: ROTANA HOTEL Page 9/14
Licensee: Freyssinet Gulf LLC 10/01/2011 11:31:49 License No.: 29846110705UPP
Bending Moments
Load Cases
Column Actions
Col No. 1 Secondary Secondary Prestress Prestress Self Extra Live
Transfer Service Transfer Service Weight Dead Load
Load
Moment Above kNm 0 0 0 0 -0 -0 -0
Moment Below kNm -397.77 -346.04 -397.77 -346.04 503.12 235.57 235.57
Reaction kN 33.03 27.97 33.03 27.97 349.49 163.64 163.64
Elastic Rotation #.# 0 0 -6.01e-4 -5.23e-4 7.61e-4 3.56e-4 3.56e-4
Elastic Axial Shortening mm 0 0 -0 -0 -0 -0 -0

Col No. 2 Secondary Secondary Prestress Prestress Self Extra Live


Transfer Service Transfer Service Weight Dead Load
Load
Moment Above kNm 382.96 328.31 382.96 328.31 -491.88 -230.31 -230.31
Moment Below kNm 500.31 428.92 500.31 428.92 -642.6 -300.88 -300.88
Reaction kN -33.03 -27.97 -33.03 -27.97 435.39 203.86 203.86
Elastic Rotation #.# 0 0 1.41e-4 1.21e-4 -1.81e-4 0 0
Elastic Axial Shortening mm 0 0 0 0 -0 -0 -0

Load Combinations
Column Actions
Col No. 1 Service Service Ultimate Ultimate Ultimate Ultimate
(Reversal) Flexure Flexure Shear Shear
(Reversal) (Reversal)
Moment Above kNm 0 0 0 0 0 0
Moment Below kNm 628.22 628.22 762 1065.05 762 1065.05
Reaction kN 704.74 704.74 797.67 1008.18 797.67 1008.18
Elastic Rotation #.# 9.5e-4 9.5e-4 1.68e-3 2.13e-3 1.68e-3 2.13e-3
Elastic Axial Shortening mm -0.1 -0.1 -0.1 -0.2 -0.1 -0.2

Col No. 2 Service Service Ultimate Ultimate Ultimate Ultimate


(Reversal) Flexure Flexure Shear Shear
(Reversal) (Reversal)
Moment Above kNm -624.18 -624.18 -1051.24 -754.97 -754.97 -1051.24
Moment Below kNm -815.45 -815.45 -1373.38 -986.31 -986.31 -1373.38
Reaction kN 815.14 815.14 1193.15 930.9 930.9 1193.15
Elastic Rotation #.# -2.3e-4 -2.3e-4 -5.08e-4 -3.99e-4 -3.99e-4 -5.08e-4
Elastic Axial Shortening mm -0 -0 -0 -0 -0 -0

Ultimate Flexure

kNm1 2
-3200
-2400 -1959
-1600 -866
-800
0
800
1600
2400
2301
3200
0 14700mm

Moment Moment 1 Moment 2

1 2
kN
1200 978
800
400
0
-400
-800
-1200
-1133
-1600
0 14700mm

Shear Shear 1 Shear 2


RAPT 6.2.1.8 Project Name: ROTANA HOTEL Page 10/14
Licensee: Freyssinet Gulf LLC 10/01/2011 11:31:51 License No.: 29846110705UPP
Flexural Design
Ultimate

1 2
mm2
670
5400 4774
4500
3600
2700
1800
900
0
-900 389
0 14700mm

Reinforcement Top Total Bottom Total Top Ultimate Bottom Ultimate Min Top Min Bot

1 2
kNm
-3000
-2000
-1000
0
1000
2000
3000
4000
0 14700mm

Capacity Minimum Ultimate Design Initial Final

1 2
1
0.491

0.446
0.8
0.6
0.4
0.2
0
-0.2
-0.4
0.473

-0.6
0 14700mm

Neutral Axis Depth Initial Final

Span 1
Design Comments:-
- Compression reinforcement added at left support hinge location for ductility in accordance with BS8110 cl.3.2.2.1(b) & cl.4.2.3.1(c). Asc = 388.96mm2 @
200mm
- Before adding compression reinforcement to solve a ductility problem RAPT has noticed that the ductility problem was initially caused by a low value of
effective depth as the reinforcement and/ or tendons are a long way from the tension face. Adding steel near the tension face has removed the ductility
problem.

Service
Maximum Moment Condition

1 2
MPa MPa
-6.49
-8 -200
-4 -100
0 0
4 100
8 200
12 300
16 400
10.82
0 14700mm

Gross Stress Top Gross Stress Bottom Cracked Compression Axial Prestress Limits Reinforcement Tension Limits
RAPT 6.2.1.8 Project Name: ROTANA HOTEL Page 11/14
Licensee: Freyssinet Gulf LLC 10/01/2011 11:31:53 License No.: 29846110705UPP
Reversal Moment Condition

1 2
MPa MPa
-6.42
-8 -200
-4 -100
0 0
4 100
8 200
12 300
16 400
10.78
0 14700mm

Gross Stress Top Gross Stress Bottom Cracked Compression Axial Prestress Limits Reinforcement Tension Limits

Span 1
Design Comments:-
- SERVICE - CLASS 3 member to BS8110 cl.4.3.4.3(b,c) as Tensile Stress in Concrete > 2.28MPa.
- Increase in stress from decompression to working exceeds 200MPa in at least one steel layer. Reinforcement has been added to reduce stress change
below this maximum value. Refer RAPT manual Section 7.7.6

Transfer Prestress
Maximum Moment Condition

1 2
MPa MPa
-2 -0.78 -30
0 0
2 30
4 60
6 90
8 120
10 8.71 150
0 14700mm

Gross Stress Top Gross Stress Bottom Cracked Compression Reinforcement Tension

Permanent
Maximum Moment Condition

1 2
MPa MPa
-6 -4.57 -120
-3 -60
0 0
3 60
6 120
9 180
12 240
15 8.85 300
0 14700mm

Gross Stress Top Gross Stress Bottom Cracked Compression Axial Prestress Limits Reinforcement Tension

1 2
MPa MPa
-6 -4.57 -120
-3 -60
0 0
3 60
6 120
9 180
12 240
15 8.85 300
0 14700mm
RAPT 6.2.1.8 Project Name: ROTANA HOTEL Page 12/14
Licensee: Freyssinet Gulf LLC 10/01/2011 11:31:56 License No.: 29846110705UPP
Span 1
Design Comments:-
- SERVICE - CLASS 3 member to BS8110 cl.4.3.4.3(b,c) as Tensile Stress in Concrete > 2.28MPa.
- Increase in stress from decompression to working exceeds 200MPa in at least one steel layer. Reinforcement has been added to reduce stress change
below this maximum value. Refer RAPT manual Section 7.7.6

Shear Design
Beam
Span 1
Locat V* Mv* Mdec d Ast bv phi Vuc phi Vut phi Vu Asv/s Spacing of Sets Shear Comments
2 legs 2 legs 2 legs
T8 T10 T12
mm kN kNm kNm mm mm2 mm kN kN kN mm2/mm mm mm mm A
200 978.23 -866.4 313.43 474.9 670 943.3 1.91e5 1576.03 1576.03 0.86 116.8 182.3 262.4 Minimum Steel
1000 858.43 -131.74 207.43 331.2 266.68 943.3 1226.02 1545.59 1226.02 0.86 116.8 182.3 262.4 Minimum Steel
1499 783.7 277.97 563.09 787.3 0 943.3 1555.55 1527.78 1527.78 0.86 116.8 182.3 262.4 Minimum Steel
1501 783.4 279.53 -288.04 787.4 0 886.7 441.56 1780.44 441.56 0.99 101.5 158.4 228.1
2044 706.01 651.86 -46.89 817.6 0 886.7 458.48 1741.25 458.48 0.81 124.3 193.9 279.2 Minimum Steel
2587 624.7 1013.15 168.53 841.6 0 886.7 471.96 1699.48 471.96 0.81 124.3 193.9 279.2 Minimum Steel
3130 543.38 1330.28 680.01 604.4 0 886.7 462.38 1937.74 462.38 0.81 124.3 193.9 279.2 Minimum Steel
3675 475.14 1517.83 849.47 649.1 0 886.7 464.23 1896.44 464.23 0.81 124.3 193.9 279.2 Minimum Steel
4900 291.85 1859.43 1135.21 727.2 0 886.7 413.42 1798.78 413.42 0.81 124.3 193.9 279.2 Minimum Steel
6125 132.91 2127.1 1290.68 774 0 886.7 434.04 1697.45 434.04 0.81 124.3 193.9 279.2 Minimum Steel
7350 -139 2081.1 1317.28 789.6 0 886.7 442.79 1594.88 442.79 0.81 124.3 193.9 279.2 Minimum Steel
8575 -297.52 1950.91 1215.81 774 0 886.7 434.04 1694.81 434.04 0.81 124.3 193.9 279.2 Minimum Steel
9800 -466.62 1575.17 986.54 727.2 0 886.7 505.66 1794.33 505.66 0.81 124.3 193.9 279.2 Minimum Steel
11025 -650.06 891.2 629.12 649.1 0 886.7 619.51 1892.84 619.51 0.81 124.3 193.9 279.2 Minimum Steel
11568 -725.29 568.22 429.51 604.6 0 886.7 679.5 1935.83 679.5 0.81 124.3 193.9 279.2 Minimum Steel
12111 -806.61 152.31 -117.14 841.7 0 886.7 472 1695.26 472 0.91 110.9 173 249.1
12654 -887.92 -307.76 1037.74 823.7 0 886.7 2636.96 1703.65 1703.65 0.81 124.3 193.9 279.2 Minimum Steel
13199 -968.38 -802.39 1308.99 919.8 0 886.7 1700.44 1742.23 1700.44 0.81 124.3 193.9 279.2 Minimum Steel
13201 -754.63 -477.97 482.2 544.7 1576.25 943.3 850.77 1516.98 850.77 0.86 116.8 182.3 262.4 Minimum Steel
13500 -1013.45 -1100.66 527.94 602.6 2047.77 943.3 803.52 1527.49 803.52 0.86 116.8 182.3 262.4 Minimum Steel
14300 -1133.25 -1959.34 670.86 763.3 4774.26 943.3 4.14e5 1557.9 1557.9 0.86 116.8 182.3 262.4 Minimum Steel

Punching
Column Head Critical Section
Column Bh a at u d fcv P/A Asw/s min V* Mv* V*eff Vu Vumax Asv result
No.
A #.# mm mm mm mm MPa MPa mm2/mm kN kNm kN kN kN mm2 A
1 2.5 605.4 1000 3021.6 270.3 1.16 2.14 0 1008.18 1065.05 1260.22 946.17 2539.95 745.64 O K with Ties
2 1.25 981 1000 4123.9 387.3 1.01 2.1 0 1193.15 2424.62 1491.44 1607.23 4956.02 0

Deflections
Live Load on All Spans
Transfer

mm1 2
0
-1.57
-10

-20

-30

-40

-50
9354
0 14700mm
RAPT 6.2.1.8 Project Name: ROTANA HOTEL Page 13/14
Licensee: Freyssinet Gulf LLC 10/01/2011 11:31:58 License No.: 29846110705UPP
Short Term

mm1 2
0

-10
-8.1
-20

-30

-40

-50
1814
0 14700mm

Incremental

mm1 2
0

-10

-20 -16.8
-30

-40

-50
877
0 14700mm

Total Long Term

mm1 2
0

-10

-20
-18.5
-30

-40

-50
794
0 14700mm

Detailed Reinforcement
Span 1
Top Reinforcement Bottom Reinforcement

Max Section Max Section


Locat Space Area Depth Width Rebar Reqd Space Area Depth Width Rebar Reqd
mm mm mm2 mm mm A mm mm2 mm mm A
200 200.1 670 44.5 1000 4 T16 @ 298.3 0 388.96 955.5 1000 2 T16 @ 895
1000 0 266.68 44.5 1000 2 T16 @ 895 0 388.96 955.5 1000 2 T16 @ 895
1499 0 0 44.5 1000 No Steel Added 0 0 955.5 1000 No Steel Added
1501 0 0 44.5 1000 No Steel Added 0 0 955.5 1000 No Steel Added
2044 0 0 44.5 1000 No Steel Added 0 0 955.5 1000 No Steel Added
2587 0 0 44.5 1000 No Steel Added 0 0 955.5 1000 No Steel Added
3130 0 0 44.5 1000 No Steel Added 0 0 955.5 1000 No Steel Added
3675 0 0 44.5 1000 No Steel Added 0 0 955.5 1000 No Steel Added
4900 0 0 44.5 1000 No Steel Added 0 0 955.5 1000 No Steel Added
6125 0 0 44.5 1000 No Steel Added 0 0 955.5 1000 No Steel Added
7350 0 0 44.5 1000 No Steel Added 0 0 955.5 1000 No Steel Added
8575 0 0 44.5 1000 No Steel Added 0 0 955.5 1000 No Steel Added
9800 0 0 44.5 1000 No Steel Added 0 0 955.5 1000 No Steel Added
11025 0 0 44.5 1000 No Steel Added 0 0 955.5 1000 No Steel Added
11568 0 0 44.5 1000 No Steel Added 0 0 955.5 1000 No Steel Added
12111 0 0 44.5 1000 No Steel Added 0 0 955.5 1000 No Steel Added
12654 0 0 44.5 1000 No Steel Added 0 0 955.5 1000 No Steel Added
13199 0 0 44.5 1000 No Steel Added 0 0 955.5 1000 No Steel Added
13201 260.4 1576.25 44.5 1000 4 T25 @ 295.3 0 0 955.5 1000 No Steel Added
13500 160.3 2047.77 44.5 1000 5 T25 @ 221.5 0 0 955.5 1000 No Steel Added
14300 139.1 4774.26 44.5 1000 10 T25 @ 98.4 0 0 955.5 1000 No Steel Added
RAPT 6.2.1.8 Project Name: ROTANA HOTEL Page 14/14
Licensee: Freyssinet Gulf LLC 10/01/2011 11:32:01 License No.: 29846110705UPP
Shear Reinforcement
Spacing of Sets
2 legs 2 legs 2 legs Shear
Area T8 T10 T12 Comments
mm2/mm mm mm mm A
0.86 116.8 182.3 262.4 Minimum Steel
0.86 116.8 182.3 262.4 Minimum Steel
0.86 116.8 182.3 262.4 Minimum Steel
0.99 101.5 158.4 228.1
0.81 124.3 193.9 279.2 Minimum Steel
0.81 124.3 193.9 279.2 Minimum Steel
0.81 124.3 193.9 279.2 Minimum Steel
0.81 124.3 193.9 279.2 Minimum Steel
0.81 124.3 193.9 279.2 Minimum Steel
0.81 124.3 193.9 279.2 Minimum Steel
0.81 124.3 193.9 279.2 Minimum Steel
0.81 124.3 193.9 279.2 Minimum Steel
0.81 124.3 193.9 279.2 Minimum Steel
0.81 124.3 193.9 279.2 Minimum Steel
0.81 124.3 193.9 279.2 Minimum Steel
0.91 110.9 173 249.1
0.81 124.3 193.9 279.2 Minimum Steel
0.81 124.3 193.9 279.2 Minimum Steel
0.86 116.8 182.3 262.4 Minimum Steel
0.86 116.8 182.3 262.4 Minimum Steel
0.86 116.8 182.3 262.4 Minimum Steel

Design Comments:-
- SUPPORT Reinforcing Bar Spacing - Column Grid 1 - Smallest preferred reinforcement size requires bar spacing larger than maximum. It will be
necessary to use smaller bars than the preferred minimum size or a larger area of reinforcement than is required by design.
- - Column Grid 1 - Required Bar Size is smaller than the Preffered Bar Size. Maintaining the same cover will require slightly less reinforcement than
calculated.
- SPAN Reinforcing Bar spacing - Span 1 - Smallest preferred reinforcement size requires bar spacing larger than maximum. It will be necessary to use
smaller bars than the preferred minimum size or a larger area of reinforcement than is required by design.
- - Span 1 - Required Bar Size is smaller than the Preffered Bar Size. Maintaining the same cover will require slightly less reinforcement than calculated.

Reinforcement Layout

10-T25
1 2
4-T16

mm
0

-200

-400

-600

-800

-1000
2-T16

0 14700mm

Design Comments:-
- SUPPORT Reinforcing Bar Spacing - Column Grid 1 - Smallest preferred reinforcement size requires bar spacing larger than maximum. It will be
necessary to use smaller bars than the preferred minimum size or a larger area of reinforcement than is required by design.
- - Column Grid 1 - Required Bar Size is smaller than the Preffered Bar Size. Maintaining the same cover will require slightly less reinforcement than
calculated.
- SPAN Reinforcing Bar spacing - Span 1 - Smallest preferred reinforcement size requires bar spacing larger than maximum. It will be necessary to use
smaller bars than the preferred minimum size or a larger area of reinforcement than is required by design.
- - Span 1 - Required Bar Size is smaller than the Preffered Bar Size. Maintaining the same cover will require slightly less reinforcement than calculated.