Input
General
Design Code List United Kingdom - BS 8110*SAVED*
Material List United Kingdom - United Kingdom Materials*SAVED*
Reinforcement Type List Bonded Post-Tensioned
Member Type List Beam
Panel Type List Internal
Strip Type List One way - Nominal Width
Column Stiffness List Equivalent Column
Concrete - Spanning Members List 40MPa
Concrete - Columns List 40MPa
Top Reinforcement Cover mm 32
Bottom Reinforcement Cover mm 32
Self Weight Definition List Program Calculated
Pattern Live Load Y/N
Earthquake Design List None
Moment Redistribution % 0
Design Surface Levels List Extreme Surfaces
Span
Span Span Slab Panel Panel
Length Depth Width Width
Left Right
mm mm mm mm
LE 0
1 14700 350 4500 4500
RE 0
Columns
Column Column Support Column Column Column Column Column Column Transverse Capital Depth Pin Percentage Braced Column Punching
Grid Type Height Width Length Height Width Length Column below Base Column frame Shortening Shear
Reference Above Above Above below below below spacing deepest below Stiffness at this Restrained Check
section column required
A List mm mm mm mm mm mm mm mm Y/N % Y/N Y/N Y/N
1 1 Column 0 0 0 2300 1000 400 4500 0 Y 85 Y N Y
2 2 Column 2300 1000 800 2300 1000 800 4500 0 Y 85 Y N Y
Beams
Beam Beam Beam Beam Effective
Number Depth Width Width Flange
at Width
Slab
mm mm mm mm
1 1000 1000 1000 1000
RAPT 6.2.1.8 Project Name: ROTANA HOTEL Page 2/14
Licensee: Freyssinet Gulf LLC 10/01/2011 11:31:32 License No.: 29846110705UPP
Load Cases
Load Load Type Load Definition Live Load Description
Case Deflection
Case
List List Y/N A
1 Self Weight Applied Loads
2 Extra Dead Load Applied Loads
3 Live Load Applied Loads Y
1 2
kN/m
60 L1
40
20
0
0 14700mm
1 2
kN/m
60
40
L1
20
0
0 14700mm
1 2
kN/m
60
40
L1
20
0
0 14700mm
Prestress
Tendon Normal or Steel Steel Prestress Prestress Number Number Spacing Top Bottom Left Distance to Left Right
upside down Type Diameter Type Anchorage of of of Cover Cover Anchorage left Anchorage Anchorage
profiles Size Strands Tendons tendons to to Duct Reference anchorage Type Reference
Duct Column from column Column
List List List List List List #.# mm mm mm mm List
1 Strand 15.7mm MultiStrand 13 13 1 55 70 1 1500 2
2 Strand 15.7mm MultiStrand 13 13 1 55 70 1 0 1
Tendon 1 : - Details
Reverse Curve at Left Anchorage Y/N N
Reverse Curve at Right Anchorage Y/N N
Percentage Jacking Force % 80
Tendon 2 : - Details
Reverse Curve at Left Anchorage Y/N N
Reverse Curve at Right Anchorage Y/N N
Percentage Jacking Force % 80
Tendon 1 : - 1 - 13/15.7
mm
0
13
13
-300
-600
13
13
-900
920cl
330cl
1 2
710
565
440
330
240
170
115
100
145
205
85
70
75
Tendon 2 : - 1 - 13/15.7
mm
0
13
13
-300
-600
13
13
-900
330cl
920cl
1 2
205
145
100
115
170
240
330
440
565
710
75
70
85
Reinforcement
Reinforcement Reinforcement Preferred Number
Use Type Bar Size of Legs
List List #
Flexural Bar T 460MPa
Flexural Mesh A 460MPa
Shear Option 1 T 460MPa 8 2
Shear Option 2 T 460MPa 10 2
Shear Option 3 T 460MPa 12 2
Punching Shear T 460MPa 10 2
RAPT 6.2.1.8 Project Name: ROTANA HOTEL Page 6/14
Licensee: Freyssinet Gulf LLC 10/01/2011 11:31:41 License No.: 29846110705UPP
Reinforcement
Maximum Minimum Minimum Minimum Span Minimum Span Infill Stagger
Bar Bar Continuous Reinforcement Reinforcement Bars Bars
Spacing Spacing Reinforcement into End into Internal
Support Support
mm mm #.# #.# #.# Y/N Y/N
Support Reinforcement 300 60 0 N N
Span Reinforcement 300 60 0 0 N N
1 2
mm
0
-200
-400
-600
-800
-1000
0 14700mm
Design Data
Capacity Reduction factor (phi) for Flexure #.# 1
Capacity Reduction factor (phi) for Shear #.# 1
Material Factor for Concrete in Flexure #.# 1.5
Material Factor for Concrete in Shear #.# 1.25
Material Factor for Reinforcement #.# 1.05
Maximum Ratio of Neutral Axis Depth for Ductility #.# 0.5
Ductility Check at Left End Column Y/N Y
Ductility Check at Right End Column Y/N Y
Minimum Reinforcement Strength Limit - #.## x M* #.# 0
Flexural Critical Section - Consider Transverse Beams Y/N Y
Flexural Critical Section - Distance from centre of Support #.# -1
Beam Left Sideface Cover (Internal) mm 25
Beam Right Sideface cover mm 40
Prestress Minimum Reinforcement Basis List Program Default
Shear Enhancement at Supports Y/N Y
Ast Value in Shear Calculations List Calculated
AS3600 Shear Fitment Hooks Located at List Top of Fitment
Moment Diagram Offset For Flexure Calculations List Code Default
Limit Reinforcement Strain Y/N N
Material Properties
Concrete
Description 40MPa
Characteristic Compressive Strength 40
Mean Compressive Strength 46.53
Lower Characteristic Tensile Strength 3.16
Upper Characteristic Tensile Strength 5.06
Concrete Weight 2447
Design Concrete Modulus 28000
Mean Concrete Modulus 29305
Ultimate Concrete Modulus 28401.9
Basic Shrinkage Strain 600
Basic Creep Factor 3.4
Concrete Strain Limit 0.004
Prestress Strand
Diameter Area Breaking 0.2% 1% Breaking Design Elastic Plastic Basic Weight Material Material Material Material Capacity
Load Proof Stress Strain Strain Modulus Modulus Relaxation Factor Factor Capacity Reduction Factor
Stress Limit Flexure Shear Reduction - Shear
Factor - Flexure
15.7 150 265 85 87.5 0.06 90 1.95e5 2200 2 1.18 -1 -1 -1 -1
Bonded Multistrand
Anchorage Description Transfer Anchor Draw-in Maximum Set as
Size Concrete Friction Jacking default
Strength Force
13 30 2 6 80 N
Elevation view
1 2
mm
0
-200
-400
-600
-800
-1000
0 14700mm
Plan view
1 2
mm
-2000
-1000
1000
2000
0 14700mm
1 2
mm
2000
1000
-1000
-2000
0 14700mm
Warnings
Input
Warning:At 1500mm from the left end of this span, this tendon duct either violates nominated top cover or is outside the concrete section in this span.
Output
Warning:SUPPORT Reinforcing Bar Spacing There have been problems in determining a bar size to satisfy the design spacing requirements. See
Detailed Reinforcement Design Comments.
Warning:SPAN Reinforcing Bar spacing There have been problems in determining a bar size to satisfy the design spacing requirements. See Detailed
Reinforcement Design Comments.
RAPT 6.2.1.8 Project Name: ROTANA HOTEL Page 9/14
Licensee: Freyssinet Gulf LLC 10/01/2011 11:31:49 License No.: 29846110705UPP
Bending Moments
Load Cases
Column Actions
Col No. 1 Secondary Secondary Prestress Prestress Self Extra Live
Transfer Service Transfer Service Weight Dead Load
Load
Moment Above kNm 0 0 0 0 -0 -0 -0
Moment Below kNm -397.77 -346.04 -397.77 -346.04 503.12 235.57 235.57
Reaction kN 33.03 27.97 33.03 27.97 349.49 163.64 163.64
Elastic Rotation #.# 0 0 -6.01e-4 -5.23e-4 7.61e-4 3.56e-4 3.56e-4
Elastic Axial Shortening mm 0 0 -0 -0 -0 -0 -0
Load Combinations
Column Actions
Col No. 1 Service Service Ultimate Ultimate Ultimate Ultimate
(Reversal) Flexure Flexure Shear Shear
(Reversal) (Reversal)
Moment Above kNm 0 0 0 0 0 0
Moment Below kNm 628.22 628.22 762 1065.05 762 1065.05
Reaction kN 704.74 704.74 797.67 1008.18 797.67 1008.18
Elastic Rotation #.# 9.5e-4 9.5e-4 1.68e-3 2.13e-3 1.68e-3 2.13e-3
Elastic Axial Shortening mm -0.1 -0.1 -0.1 -0.2 -0.1 -0.2
Ultimate Flexure
kNm1 2
-3200
-2400 -1959
-1600 -866
-800
0
800
1600
2400
2301
3200
0 14700mm
1 2
kN
1200 978
800
400
0
-400
-800
-1200
-1133
-1600
0 14700mm
1 2
mm2
670
5400 4774
4500
3600
2700
1800
900
0
-900 389
0 14700mm
Reinforcement Top Total Bottom Total Top Ultimate Bottom Ultimate Min Top Min Bot
1 2
kNm
-3000
-2000
-1000
0
1000
2000
3000
4000
0 14700mm
1 2
1
0.491
0.446
0.8
0.6
0.4
0.2
0
-0.2
-0.4
0.473
-0.6
0 14700mm
Span 1
Design Comments:-
- Compression reinforcement added at left support hinge location for ductility in accordance with BS8110 cl.3.2.2.1(b) & cl.4.2.3.1(c). Asc = 388.96mm2 @
200mm
- Before adding compression reinforcement to solve a ductility problem RAPT has noticed that the ductility problem was initially caused by a low value of
effective depth as the reinforcement and/ or tendons are a long way from the tension face. Adding steel near the tension face has removed the ductility
problem.
Service
Maximum Moment Condition
1 2
MPa MPa
-6.49
-8 -200
-4 -100
0 0
4 100
8 200
12 300
16 400
10.82
0 14700mm
Gross Stress Top Gross Stress Bottom Cracked Compression Axial Prestress Limits Reinforcement Tension Limits
RAPT 6.2.1.8 Project Name: ROTANA HOTEL Page 11/14
Licensee: Freyssinet Gulf LLC 10/01/2011 11:31:53 License No.: 29846110705UPP
Reversal Moment Condition
1 2
MPa MPa
-6.42
-8 -200
-4 -100
0 0
4 100
8 200
12 300
16 400
10.78
0 14700mm
Gross Stress Top Gross Stress Bottom Cracked Compression Axial Prestress Limits Reinforcement Tension Limits
Span 1
Design Comments:-
- SERVICE - CLASS 3 member to BS8110 cl.4.3.4.3(b,c) as Tensile Stress in Concrete > 2.28MPa.
- Increase in stress from decompression to working exceeds 200MPa in at least one steel layer. Reinforcement has been added to reduce stress change
below this maximum value. Refer RAPT manual Section 7.7.6
Transfer Prestress
Maximum Moment Condition
1 2
MPa MPa
-2 -0.78 -30
0 0
2 30
4 60
6 90
8 120
10 8.71 150
0 14700mm
Gross Stress Top Gross Stress Bottom Cracked Compression Reinforcement Tension
Permanent
Maximum Moment Condition
1 2
MPa MPa
-6 -4.57 -120
-3 -60
0 0
3 60
6 120
9 180
12 240
15 8.85 300
0 14700mm
Gross Stress Top Gross Stress Bottom Cracked Compression Axial Prestress Limits Reinforcement Tension
1 2
MPa MPa
-6 -4.57 -120
-3 -60
0 0
3 60
6 120
9 180
12 240
15 8.85 300
0 14700mm
RAPT 6.2.1.8 Project Name: ROTANA HOTEL Page 12/14
Licensee: Freyssinet Gulf LLC 10/01/2011 11:31:56 License No.: 29846110705UPP
Span 1
Design Comments:-
- SERVICE - CLASS 3 member to BS8110 cl.4.3.4.3(b,c) as Tensile Stress in Concrete > 2.28MPa.
- Increase in stress from decompression to working exceeds 200MPa in at least one steel layer. Reinforcement has been added to reduce stress change
below this maximum value. Refer RAPT manual Section 7.7.6
Shear Design
Beam
Span 1
Locat V* Mv* Mdec d Ast bv phi Vuc phi Vut phi Vu Asv/s Spacing of Sets Shear Comments
2 legs 2 legs 2 legs
T8 T10 T12
mm kN kNm kNm mm mm2 mm kN kN kN mm2/mm mm mm mm A
200 978.23 -866.4 313.43 474.9 670 943.3 1.91e5 1576.03 1576.03 0.86 116.8 182.3 262.4 Minimum Steel
1000 858.43 -131.74 207.43 331.2 266.68 943.3 1226.02 1545.59 1226.02 0.86 116.8 182.3 262.4 Minimum Steel
1499 783.7 277.97 563.09 787.3 0 943.3 1555.55 1527.78 1527.78 0.86 116.8 182.3 262.4 Minimum Steel
1501 783.4 279.53 -288.04 787.4 0 886.7 441.56 1780.44 441.56 0.99 101.5 158.4 228.1
2044 706.01 651.86 -46.89 817.6 0 886.7 458.48 1741.25 458.48 0.81 124.3 193.9 279.2 Minimum Steel
2587 624.7 1013.15 168.53 841.6 0 886.7 471.96 1699.48 471.96 0.81 124.3 193.9 279.2 Minimum Steel
3130 543.38 1330.28 680.01 604.4 0 886.7 462.38 1937.74 462.38 0.81 124.3 193.9 279.2 Minimum Steel
3675 475.14 1517.83 849.47 649.1 0 886.7 464.23 1896.44 464.23 0.81 124.3 193.9 279.2 Minimum Steel
4900 291.85 1859.43 1135.21 727.2 0 886.7 413.42 1798.78 413.42 0.81 124.3 193.9 279.2 Minimum Steel
6125 132.91 2127.1 1290.68 774 0 886.7 434.04 1697.45 434.04 0.81 124.3 193.9 279.2 Minimum Steel
7350 -139 2081.1 1317.28 789.6 0 886.7 442.79 1594.88 442.79 0.81 124.3 193.9 279.2 Minimum Steel
8575 -297.52 1950.91 1215.81 774 0 886.7 434.04 1694.81 434.04 0.81 124.3 193.9 279.2 Minimum Steel
9800 -466.62 1575.17 986.54 727.2 0 886.7 505.66 1794.33 505.66 0.81 124.3 193.9 279.2 Minimum Steel
11025 -650.06 891.2 629.12 649.1 0 886.7 619.51 1892.84 619.51 0.81 124.3 193.9 279.2 Minimum Steel
11568 -725.29 568.22 429.51 604.6 0 886.7 679.5 1935.83 679.5 0.81 124.3 193.9 279.2 Minimum Steel
12111 -806.61 152.31 -117.14 841.7 0 886.7 472 1695.26 472 0.91 110.9 173 249.1
12654 -887.92 -307.76 1037.74 823.7 0 886.7 2636.96 1703.65 1703.65 0.81 124.3 193.9 279.2 Minimum Steel
13199 -968.38 -802.39 1308.99 919.8 0 886.7 1700.44 1742.23 1700.44 0.81 124.3 193.9 279.2 Minimum Steel
13201 -754.63 -477.97 482.2 544.7 1576.25 943.3 850.77 1516.98 850.77 0.86 116.8 182.3 262.4 Minimum Steel
13500 -1013.45 -1100.66 527.94 602.6 2047.77 943.3 803.52 1527.49 803.52 0.86 116.8 182.3 262.4 Minimum Steel
14300 -1133.25 -1959.34 670.86 763.3 4774.26 943.3 4.14e5 1557.9 1557.9 0.86 116.8 182.3 262.4 Minimum Steel
Punching
Column Head Critical Section
Column Bh a at u d fcv P/A Asw/s min V* Mv* V*eff Vu Vumax Asv result
No.
A #.# mm mm mm mm MPa MPa mm2/mm kN kNm kN kN kN mm2 A
1 2.5 605.4 1000 3021.6 270.3 1.16 2.14 0 1008.18 1065.05 1260.22 946.17 2539.95 745.64 O K with Ties
2 1.25 981 1000 4123.9 387.3 1.01 2.1 0 1193.15 2424.62 1491.44 1607.23 4956.02 0
Deflections
Live Load on All Spans
Transfer
mm1 2
0
-1.57
-10
-20
-30
-40
-50
9354
0 14700mm
RAPT 6.2.1.8 Project Name: ROTANA HOTEL Page 13/14
Licensee: Freyssinet Gulf LLC 10/01/2011 11:31:58 License No.: 29846110705UPP
Short Term
mm1 2
0
-10
-8.1
-20
-30
-40
-50
1814
0 14700mm
Incremental
mm1 2
0
-10
-20 -16.8
-30
-40
-50
877
0 14700mm
mm1 2
0
-10
-20
-18.5
-30
-40
-50
794
0 14700mm
Detailed Reinforcement
Span 1
Top Reinforcement Bottom Reinforcement
Design Comments:-
- SUPPORT Reinforcing Bar Spacing - Column Grid 1 - Smallest preferred reinforcement size requires bar spacing larger than maximum. It will be
necessary to use smaller bars than the preferred minimum size or a larger area of reinforcement than is required by design.
- - Column Grid 1 - Required Bar Size is smaller than the Preffered Bar Size. Maintaining the same cover will require slightly less reinforcement than
calculated.
- SPAN Reinforcing Bar spacing - Span 1 - Smallest preferred reinforcement size requires bar spacing larger than maximum. It will be necessary to use
smaller bars than the preferred minimum size or a larger area of reinforcement than is required by design.
- - Span 1 - Required Bar Size is smaller than the Preffered Bar Size. Maintaining the same cover will require slightly less reinforcement than calculated.
Reinforcement Layout
10-T25
1 2
4-T16
mm
0
-200
-400
-600
-800
-1000
2-T16
0 14700mm
Design Comments:-
- SUPPORT Reinforcing Bar Spacing - Column Grid 1 - Smallest preferred reinforcement size requires bar spacing larger than maximum. It will be
necessary to use smaller bars than the preferred minimum size or a larger area of reinforcement than is required by design.
- - Column Grid 1 - Required Bar Size is smaller than the Preffered Bar Size. Maintaining the same cover will require slightly less reinforcement than
calculated.
- SPAN Reinforcing Bar spacing - Span 1 - Smallest preferred reinforcement size requires bar spacing larger than maximum. It will be necessary to use
smaller bars than the preferred minimum size or a larger area of reinforcement than is required by design.
- - Span 1 - Required Bar Size is smaller than the Preffered Bar Size. Maintaining the same cover will require slightly less reinforcement than calculated.