Sie sind auf Seite 1von 1

1 GND GND

ODF ODF

+4.60

19
18
17
16
15
13
11
10
09
08
07
06
05
03
02
01

20
14
12
04
DCDU RJK39 101
BJKN06 BJKN07 RJK41
2.2 & 2.3

#6

8
UPS UPS UPS UPS
RECT

PAC#6
ELTEK RJK33 BJKN16 RJK35 RJK40 102

PAC LIEBERT

08

20
19
17
16
15
14
13
12
11
10
07
06
05
04
03
01

18
09
02
Cisco Patch CCN
PDU DC Catalyst DCN CIS CO 103
494 8 Pan el ROUTE R CAT IP MPL S
RECT 451 0 ROUTE R IT PGD MD3- PGD MDS4- PLA TFORM
ISAT ISAT SWITCH 494 8 OPE RA TIO HUA WEI

11
CORE Core JUNIPER BACKUP 650 9 509
CORE CORE JUNIPER SISDKM N RACK 4 104
AOP 201 2 AOP 201 2 IN 201 2 201 3
AOP 201 2 AOP 201 2 IN 201 2

E//3
E//1
E//2

#5
PAC LIEBERT
PAC#5
POD-1

20
19
18
17
16
15
14
12
11
10
09
08
07
04
03
02
01

13
06
05
105
SMPP
ACPDU 2.1 PLA TFORM PLA TFORM PLA TFORM PLA TFORM PLA TFORM PLA TFORMPLA TFORM PLA TFORMPLA TFORM PLA TFORM PLA TFORM PLA TFORM PLA TFORM PLA TFORM PLA TFORM PLA TFORM
PLN HUA WEI HUA WEI HUA WEI HUA WEI HUA WEI HUA WEI HUA WEI HUA WEI HUA WEI HUA WEI HUA WEI HUA WEI GATEWAY
HUA WEI HUA WEI HUA WEI HUA WEI 201 3 106

17
GND

GND
#7
PAC#7
PAC LIEBERT

SDP UPS1
20
19
17
16
15
14
13
12
11
10
08
07
06
05
04
03
01

18
09
02

New PDU DC IN
EXP2013 AJKT25 NJK T19 ECMS
AJKT28 EMMJK T25 IN 201 2 EMCS ECMS EMCS 107
AJKT26 IT BACKUP AIR #1 AIR #2 Ser ver DJK T56
AJKT29 s/d Pro duction Test Middlewar e

20
AJKT27 EID 201 3 201 3 PROD& DJK T DJK T DJK T DJK T AFNJK T01 SDP DJK T DJK T
AJKT31 EMMJK T31 Storage Storage EID
AJKT31 IN 201 2 NJK T20 TEST 34-354 3 36-37-44 38-39-45 40-41-42 AFNJK T04 BCDJK T01 46-47-48 49-50-51 108
PDU DC RECT CORE IN 201 2 IN 201 2 IN 201 2 IN 201 2 IN 201 2

SDP UPS2
AOP 2012
IN 201 2 IN 201 2 IN 201 2 NMTJKT01
(PDU BY EID)
JALUR KA BEL DATA

#4
PAC#4
PAC LIEBERT
POD-2

20
19
18
17
16
15
14
13
12
10
09
08
07
05
04
03
02
01

11
06

TEST B ED NEXT G EN OCCJK T 109

18
OCCJK T AJKT DJK T OO CJKT DJK T DJK T DJK T DJK T DJK T OCCJK T DJK T DJK T
NJK T23 NJK T23 NJK T25 CRS,OCC,S CHA RG & 17-22
1-8 39-45 52-53-54-55 9-16 57-58-59-60 61-62-63-67 64-65-66-68 69-70-71-72 73-74-75 25-26 76-77-78 79-80
DP,AIR BILL 23-24 110
PAC#10

JALUR KA BEL POWER


20
19
17
16
15
14
13
12
11
10
08
07
06
05
04
03
01

18
09
02

PRBT PRBT PRBT PRBT


HWI HWI HWI HWI DnD RSP LBP DIG ITAL DIG ITAL NOKIA CLOCK APC 111
VAS VAS VAS VAS
NETWO RK NETWO RK ATAE UAP 660 0 Primatek Starhome MII MUSIC MUSIC NETVIE WE OSCILLO DRA JK01 RACK
Huawei Huawei Huawei Huawei
201 3 201 3

HWI
1 2 201 4 201 3 201 4 01 02 R S ERVER QUARTZ 112

18
RBT_Exp
201 3 201 3
GND

GND
#3
5

PAC#3
20

PAC LIEBERT
POD-3

19
18
17
16
15
14
13
12
10
09
08
07
05
04
03
02
01

11
06

DCP DU 2.7
PowerO ne SAP CP GD1
SAP CP GD6 SAP CP GD8 113
0

14
SMS OSS RC OSS RC SYNERGY SYNERGY
WJK20 ENIQ ENM 2G CORE 2G CORE
FIREWALL APC APC
#7

PDU#2 SAP CP GD7 SAP CP GD9 DJK T1 114


PAC#8

PowerO ne
PAC LIEBERT

(Redun dant)

20
19
18
17
16
15
14
13
12
10
09
08
07
05
04
03
02
01

11
06

PDU#1
PowerO ne
(MAIN) PROPO SED PROPO SED PROPO SED PROPO SED RNC_ BSC_ 115
HLR BE #1 HLR BE #2 HLR BE #3 HLR FE #1 Pon dok Pon dok SDP EXP SDP EXP SDP EXP SDP EXP SDP EXP SDP EXP
JKT3 JKT3 JKT3 JKT3 Ged e_ Ged e_ HUA WEI HUA WEI HUA WEI HUA WEI HUA WEI HUA WEI
AC

12
INV

PDU#1A 116
H/6
H/5
H/4
H/3
H/2
H/1
PANEL

HUA WEI HUA WEI HUA WEI HUA WEI 01 01


PowerO ne
(Redun dant)
Temporary

PAC#11 #2
PAC#12

POD-4

20
19
17
16
15
14
13
12
11
10
08
07
06
05
04
03
01

18
09
02

PAC LIEBERT
PAC#2
HSS-PCRF PCRF PCRF
SGS N- DNS- HLR-BE HLR-BE HLR-BE HLR-BE 117
-testbed -BE- -BE- HLR-FE HLR-FE HLR-BE HLR-BE
testbed PGD1 -JKT1 -JKT1 -JKT1 -JKT1 HUA WEI DRA/DEA DRA/SANEX

16
-PGD PGD1 PGD1 -JKT1 -JKT2 -JKT1 -JKT1
-PGD Huawei expansion expansion expansion expansion UGW981 1 HUA WEI HUA WEI 118
Huawei Huawei Huawei Huawei Huawei Huawei Huawei
PAC#13

final phase final phase final phase final phase

Huawei

GND
20
19
17
16
15
14
13
12
11
10
08
07
06
05
04
03
01

18
09
02

Huawei
7 ACPDB 119

PDF#1 for PDF#2 for


RECTIFIE RECTIFIE

BSC & RNC BSC & RNC


RECTIFIE RECTIFIE RECT 1 RECT 2 RECT 3
RECT RECT 1 RECT 2 DCP DB JUNCTION INV ERTER INV ERTER INV ERTER RECTIFIER DCP DB
R Delta Delta NETSURE ACP ELTEK Eltek
RELTEK Eltek
RELTEK
AOP 201 2 DELTA
RDELTA RECT RECT
GND

Hariff 01 Hariff 01 BOX SYS SYS SYS ACPDB 03


Eltek3000
FP2 3000 120
HARIFF EMERSON DIS TRIBUTION FP2033000 FP203
LANTAI 2 1 2 3
20
19
17
16
15
14
13
12
11
10
08
07
06
05
04
03
01

18
09
02

#1
PAC#1
PAC#9

PAC LIEBERT

PDB IN & OUT UPS #2 UPS #1 121


RECT
UPS 2x80 KVA 80 KVA 80 KVA AC RECT INV ERTER
RECTIFIE AC AC RECTIFIE DC RECTIFIE
SYS RECTI
POWE RWARE POWE RWA POWE RWA PANEL SYS SYS DIS TRIBUSI PANEL DIS TRIBUSI AC DC
R #2
R Eltek Eltek
RELTEK 122
DELTASINDO RE RE INV #1 #1 #1 IN #1 INV #2 IN #2 DIS TRIBUSI DIS TRIBUSI
Huawei MPN
02 FP2
02HE
DELTA DELTA WEP WEP WEP WEP MPN MPN
ELTEK
SINDO SINDO

BSS AREA ( BSC,TRANSCODER, BTS )

MDP AC INP UT RECTIFIE R DC RECTI Juntion Box

MDP
GND

Panel PAC
PEX LPC GND GND

8
FLOOR
MSC PONDOK GEDE 2

13 14 15 16 17 18 19 20 21 22 23 24
nd

LOB BY

12

11 10 9 8 7 6 5 4 3 2 1