Run XFOIL and type 'naca0012', 'oper' to enter the calculation mode and solve 0 incidence solution. Type 'alfa 0'. Repeat several times to type 'a' if the PltLib window doesn't show the plot well. Re-calculate alfa=0 solution and run 0 to 20 deg. In steps of 5 deg. And write the CL and CDp from the screen.
Run XFOIL and type 'naca0012', 'oper' to enter the calculation mode and solve 0 incidence solution. Type 'alfa 0'. Repeat several times to type 'a' if the PltLib window doesn't show the plot well. Re-calculate alfa=0 solution and run 0 to 20 deg. In steps of 5 deg. And write the CL and CDp from the screen.
Copyright:
Attribution Non-Commercial (BY-NC)
Verfügbare Formate
Als PDF, TXT herunterladen oder online auf Scribd lesen
Run XFOIL and type 'naca0012', 'oper' to enter the calculation mode and solve 0 incidence solution. Type 'alfa 0'. Repeat several times to type 'a' if the PltLib window doesn't show the plot well. Re-calculate alfa=0 solution and run 0 to 20 deg. In steps of 5 deg. And write the CL and CDp from the screen.
Copyright:
Attribution Non-Commercial (BY-NC)
Verfügbare Formate
Als PDF, TXT herunterladen oder online auf Scribd lesen
[associated with NotesPJ4.txt] EAE127 Download XFOIL http://web.mit.edu/drela/Public/web/xfoil/ Part I.Run XFOIL and type naca0012 type ‘gdes’ to plot profile and ‘hard’ to output plot.ps type ‘return key’ to exit from ‘gdes’ routine. Type ‘quit’ to close XFOIL
by ‘Alt’+ ‘Print Screen’ Download s1223.dat from class web. Run XFOIL and type ‘load s1223.dat’ Then repeat ‘gdes’ to output the geometry Part II. a Run XFOIL (inviscid) type: ‘naca0012’, ‘oper’ to enter the calculation mode and solve 0 incidence solution. Type ‘alfa 0’.
Repeat several times to type ‘alfa 0’ if the
PltLib window doesn’t show the plot well. Run : alfa=0 to -20 in steps of 5 deg. and write the CL and CDp from the screen.
Re-calculate alfa=0 solution and
run 0 to 20 deg. b.& c. Viscous polar calculation Run XFOIL type:’naca0012’, ‘oper’ then type ‘visc’ to enable viscous mode. type: 300000 for Re #. Prompt changes to .OPERv> Specify output file name. Type: pacc Specify 2 file names for example, polar_naca0012_300e3.dat Dump_naca0012_300e3.dat. Now files are opened. Screen tells ‘polar accumulation enabled’ Calculate alfa 0 case for an initial solution. Calculate from this solution, alfa 0, over the given range of incidence in steps of 1 deg. If the code doesn’t converge, about 14 deg., you will have to moving in 0.5 deg to get convergence. sequence run option Instead of using a single calculation by specifying alfa, there is a sequence command. The following command run from alfa 0 to -13 in steps of alfa -1. OPERv> aseq 0 -13 -1 You can plot polar from your output data as well. d. Plotting Download the Pplot from the XFOIL webpage. Run Pplot. Type 1 and type polar file name you output by XFOIL. Then type ‘enter key’ Type 4 to output the polar plot. Type 0 to close pplot. Rename the plot.ps to different name.ps double click the ps file to open by the GSview. Save the plot by screen dump, ‘Alt’ + ‘Print Screen’ 2.d Plot boundary layer parameters
As we did in 2.b and 2.c, run specified
case in viscous mode. For example, >naca0012 >oper >visc >1000000 >alfa 0 Then type >? You find Vplo as BL variable plot. Type vplo and type > ? to see a list of variables Type ‘cf’ and type ‘hard’ to save the plot. Copy and past the plot.ps in different name. (Program is using the file and cannot rename it.) Repeat ‘dt’ for upper surface δ * Θ Repeat ‘db’ for lower surface δ * Θ Repeat ‘h’ for the form factor H Plot everything by excel or Matlab • If you like to plot from data files, type ‘dump’ and specify the filename to obtain the data files.