Sie sind auf Seite 1von 8

UV Systems

For Air
INDEX

UV Systems For Air ............................................................................................................................................... 3


UV Systems For Air
Code: 24024001
Portable UV sterilizer for air

Features:
- 99% destruction of bacteria, viruses.
- Quick sterilization.
- Safe and durable.

Wavelength: 270-285nm
Lamp power: 100mA
Material: PC (polycarbonate)
Battery capacity: 500mAh (lithium battery)

Applications:
Maternal and infant supplies, office supplies, Express box, bathrooms, furniture surfaces, hotels.
Code: 24024002
Portable 2,5W. UV-Ozone system for air

Variants
Code Description
24024002-01 Portable UV-Ozone system for air 2,5W

Through the design of ultraviolet and ozone in a synchronized way, ultraviolet rays can kill microorganisms
by destroying the DNA and RNA of microorganisms. Some kind of UV lamps can emit both 254nm and
185nm UV light. 254nm is the irradiation necessary for kill bacteria, 185nm is the irradiation for generate
ozone in the air. This systems equip with cold cathode lamp which can emit 254nm and 185nm uv light.
That’s why it can generate ozone.

Features:
- 99% destruction of bacteria, viruses.
- Quick sterilization.

30 March 2021 3/8


Power: 2.5W.
Voltage: 5V.
Material: ABS (acrylonitrile butadiene styrene)
Application area:
Code: 24024003
Portable 40W. UV system for air with remote control

Variants
Code Description
24024003-01 Portable 40W. UV system for air with remote control

Features:
- 99% destruction of bacteria, viruses in the air.
- Keep the air cycle in motion to obtain complete sterilization.
- 3 time settings. 30/60/120 minutes, also 24 hours a day, 7 days a week.
- 3 speed settings.
- H type germicidal lamp, high transmission compact.
- Integrated fans for air ventilation.
- Retractable handle for easy movement.

Power: 40W.
Voltage: 220V.
Frequency: 50/60Hz

Room sanitization times:


< 20m2 = 30 minutes
20-40m2 = 60 minutes
40-60m2 = 120 minutes
> 60 m2 = 24h / 7 days

Operating mode:
- Stand-by mode for closed fans (IMG. A).
- Open fan operating mode (IMG. B).
- 30 seconds delay in going into operation.

30 March 2021 4/8


Code: 24024004
Trolley UV system from 60W. to 120W. for air

Variants
Code Description
24024004-01 Trolley UV system for air 60W. (30W.x2) without infrared sensor, alarm and time delay switch
24024004-02 Trolley UV system for air 60W. (30W.x2) with infrared sensor, alarm and time delay switch
24024004-03 Trolley UV system for air 120W. (30W.x4) without infrared sensor, alarm and time delay switch
24024004-04 Trolley UV system for air 120W. (30W.x4) with infrared sensor, alarm and time delay switch
24024004-05 Trolley UV system for air 120W. (30W.x4) without infrared sensor, alarm and time delay switch
24024004-06 Trolley UV system for air 120W. (30W.x4) with infrared sensor, alarm and time delay switch

Voltage: 220V.
Frequency: 50Hz.
Input power: 180VA
Lamp power: from 60W. to 120W.
UV lamp working life: 5000 hours
Applicable static area: from 30m3 to 60m3
UV wavelength: 253.7nm
Adjusted to various angles: 90°, 135°, 180°
Material: carbon steel or stainless steel
Timer: 0-120-1440 min.
Ultraviolet radiation (distance of 1m.) 107µW/cm2 (Single tube)
Code: 24024005
UV system from 16W. to 78W. for air

Variants
Code Description
24024005-01 UV system 16W. (1x16W.) for air
24024005-02 UV system 32W. (2x16W.) for air
24024005-03 UV system 44W. (2x22W.) for air
24024005-04 UV system 78W. (2x39W.) for air

Internal sterilization chamber system using UV-C lamps.


Air is conveyed to the internal sterilization chamber built of highly reflected 304 stainless steel, further
amplifying irradiation UV-C.

30 March 2021 5/8


Concentrated irradiation of ultraviolet rays eliminates all microbial agents including pathogens.
It can operate constantly and continuously in environments with people, ensuring maximum protection.

Technical specifications:
Turn on/off on standby: Bright button.
Turn on/Remote shutdown: Radio comand.
Lamp on light UV-C.: Green led for single lamp.
Acoustic and Visual Alert (Led Color Change): System not working.
Lamp consumption indicator: Count hours.
Dust filter.

UV system 16W. (1x16W.) for air:


* Power supply: 200-240V 50/60Hz 0,25A
* Rating power: 49W.
* Treated air flow: 36m3/h.
* Philips average lamp life: 9.000h. - max. 1 year
* Dimensions (mm.): 700 L. x 290 H. x 120 D.

UV system 32W. (2x16W.) for air:


* Power supply: 2x200-240V 50/60Hz 0,25A
* Rating power: 80W.
* Treated air flow: 64m3/h.
* Philips average lamp life: 9.000h. - max. 1 year
* Dimensions (mm.): 700 L. x 290 H. x 120 D.

UV system 44W. (2x22W.) for air:


* Power supply: 2x200-240V 50/60Hz 0,25A
* Rating power: 130W.
* Treated air flow: 88m3/h.
* Philips average lamp life: 9.000h. - max. 1 year
* Dimensions (mm.): 810 L. x 290 H. x 120 D.

UV system 78W. (2x39W.) for air:


* Power supply: 2x200-240V 50/60Hz 0,25A
* Rating power: 160W.
* Treated air flow: 160m3/h.
* Philips average lamp life: 9.000h. - max. 1 year
* Dimensions (mm.): 1.200 L. x 290 H. x 120 D.

Applications
Offices, hospitals, schools, laboratories, restaurants, factories and public transport, where the concentration
of people is amplified and continuous.
Code: 24024006
UV-Ozone system from 32W. to 117W. for air

30 March 2021 6/8


Variants
Code Description
24024006-01 UV-Ozone system 32W. (2x16W.) for air:
24024006-02 UV-Ozone system 48W. (3x16W.) for air
24024006-03 UV-Ozone system 66W. (3x22W.) for air
24024006-04 UV-Ozone system 117W. (3x39W.) for air

Internal sterilization chamber system using UV-C lamps and Ozono production.
Air is conveyed to the internal sterilization chamber built of highly reflected 304 stainless steel, further
amplifying irradiation UV-C, to which it is added the emission of ozone programmed (in minutes and
intervals) via dedicated controller,
The system sterilizes the air through the irradiation of ultraviolet rays that constantly eliminate viral
pollution, avoiding contamination on the environment during working hours; sanitizes surfaces through
ozone, during the interval or closing hours, in order not to expose people to it.

Technical specifications:
Turn on/off on standby: Bright button.
Turn on/Remote shutdown: Radio comand.
Lamp on light UV-C.: Green led for single lamp.
Acoustic and Visual Alert: System not working.
Lamp consumption indicator: Count hours.
Dust filter.

UV-Ozone system 32W. (2x16W.) for air:


* Power supply: 2x200-240V 50/60Hz 0,25A
* Rating power: 49W.
* Treated air flow: 64m3/h.
* Philips average lamp life: 9.000h. - max. 1 year
* Dimensions (mm.): 700 L. x 290 H. x 120 D.

UV-Ozone system 48W. (3x16W.) for air:


* Power supply: 3x200-240V 50/60Hz 0,25A
* Rating power: 80W.
* Treated air flow: 96m3/h.
* Philips average lamp life: 9.000h. - max. 1 year
* Dimensions (mm.): 700 L. x 290 H. x 120 D.

UV-Ozone system 66W. (3x22W.) for air:


* Power supply: 3x200-240V 50/60Hz 0,25A
* Rating power: 130W.
* Treated air flow: 132m3/h.
* Philips average lamp life: 9.000h. - max. 1 year
* Dimensions (mm.): 810 L. x 290 H. x 120 D.

UV-Ozone system 117W. (3x39W.) for air:


* Power supply: 3x200-240V 50/60Hz 0,25A
* Rating power: 160W.
* Treated air flow: 234m3/h.
* Philips average lamp life: 9.000h. - max. 1 year
* Dimensions (mm.): 1.200 L. x 290 H. x 120 D.

Applications
Offices, shops, restaurants, bars, supermarkets, laboratories, medical offices, hairdressers and public
transport.

30 March 2021 7/8


Powered by TCPDF (www.tcpdf.org)