Basement Fit-out for:
Whitehall Bible Fellowship Church
All drawings and written
materials appearing herein
6/10/2020 3300 7th St - Google Maps constitute original and
unpublished work of the
architect and may not be used
or disclosed without prior
3300 7th St consent of 4/4 Architecture, LLC
Copyrighted 2020

3300 7th St, Whitehall, PA 18052

Whitehall Bible Fellowship Church

3300 7th St, Whitehall, PA 18052, USA


Basement Fit-out
Imagery ©2020 Google, Imagery ©2020 Maxar Technologies, PA Department of Conservation and Natural Resources-PAMAP/USGS, M
PROJECT SUMMARY:
The work consists of finishing an existing basement
storage area for (2) new classrooms, an open area
for gatherings, an archive room, and enclosed
storage rooms.
LOCATION OF SITE

BUILDING CODE DATA:


Applicable Code(s) & Regulations for this project:
State: Pennsylvania
2015 IBC (International Building Code)
2015 IEBC (International Existing Building Code) SITE LOCATION MAP
PA Uniform Construction Code NOT TO SCALE
2010 ADA Standards (Americans with Disabilities Act)
Map data ©2020 500 ft
BUILDING NAME :
Whitehall Bible Fellowship Church
3300 7th Street
Whitehall, PA 18052 AREA OF WORK, SEE DWG. A1.1
Contact: Mark Hargrove, 610-349-7140

BUILDING HEIGHT :
Two (2) Story (Existing)

CASSIFICATION OF WORK UNDER IEBC:


Alteration Level 2

Project Title
BUILDING CONSTRUCTION TYPE : B https://www.google.com/maps/place/3300+7th+St,+Whitehall,+PA+18052/@40.6560632,-75.5010439,16z/data=!4m5!3m4!1s0x89c43845c2f0f8d3:0xbcfd78a0507eefb4!8m2!3d40.6535006!4d-75.4976… 1/3
Type 5B (Existing - no change)

W -01
OCCUPANCY USE: EXIST. STAIR

(A-3) Place of Religious Worship w/ new accessory educational rooms


of occupant load less than 100 per room or space (IBC Section 303.1.4)

W -01
EXIST. ACCESSIBLE ENTRANCE
AREA OF BUILDING: 10,400 S.F. / floor = 20,800 G.S.F TO BASEMENT LEVEL

W -01
AREA OF WORK: 5'-0" WIDE AISLE
5,436 gross square feet
DESIGNATED VAN ACCESIBLE

W -01
TENANT OCCUPANT LOAD: SPACE, INSTALL POST
Classrooms: 3,041 n.s.f./ 20 = 154 occupants MOUNTED SIGNAGE, R7-8 &
Storage: 1,654 g.s.f/ 300 = 6 occupants R7-8P
Total = 160 occupants

48" MIN. - 60" MAX.


EXIST. EQUIP; EXIST. MECH.
TS-1: 3" X 5" EXIT SIGN

B.O. BRAILE
MEANS OF EGRESS: FUT. MACH.

Table 1017.2 - 200' max. exit access travel distance allowed


EXIST. STAIR
(3) means of egress provided

FIRE SUPRESSION SYSTEM:


Building is unsprinklered EXIST. FINISHED EXIST. LOWER
BASMENT AREA, PARKING AREA FIN. FLR.
INTERIOR FINISH : NO WORK
Corridors, Exit enclosures & Passageways - Class B (TS) TACTILE SIGNAGE
Rooms & enclosed spaces - Class C EXIST. WALKWAY
(SEE FLOOR PLANS FOR LOCATIONS)
FIRE EXTINGUISHERS: EXIST. TOILET RM.
Provide Type 2-A per 3,000 s.f.75' max. travel distance TACTILE SIGNAGE NOTES:
1. SIGNAGE TO BE ANSI A117.1 COMPLIANT.
MEANS OF EGRESS LIGHTING :
Means of Egress illumination level shall not be less than 1 foot candle at EXIST. ACCESIBLE 2. SIGNAGE TO BE 1/8" THICK ACRYLIC W/
the walking surface TOILET RM. CONTRASTING BACKGROUND AND WHITE
RAISED LETTERING.

Google Maps
1.
- Do not scale these drawings; use written dimensions only.
- Notify Architect immediately if assumed existing conditions are other than shown.
FORWARD REACH SIDE REACH
- Labor, materials and workmanship shall be in accordance with the industry standards.
REACH DEPTH 0"- <20" 20"-25" 0"-10" 24" MAX OVER 34" MAX OBSTRUCTION HT
2. REACH HEIGHT 48" MAXIMUM HIGH: 44" MAX. HIGH: 44" MAX
Each Contractor and subcontractor shall not commence work under the contract until he has provided proof of insurance of such LOW: 15" MIN. LOW: 15" MIN 46" MAXIMUM
character and in such amounts as will provide adequate protection for the owner, the members thereof, and their successors, all agents
REV. DATE DESCRIPTION
officers and servants of the owner, and the contractor and subcontractor against all claims, liabilities, damages and accidents. Such
insurance to remain in force throughout the life of the contract. THIS REACH APPLIES TO WALL MOUNTED ELECTRICAL SWITCHES AND OUTLETS, THERMOSTATS, TELEPHONES, CABINETS,
ELEVATOR VONTROL BUTTONS COAT HOOKS, SHELVES, DISPENSERS AND SIMLAR WALL MOUNTED FIXTURES PER ANSI
A117.1.2009
3.
- GC shall safely remove all demolition debris from the site to the appropriate disposal facility.
- GC shall provide temporary support of existing structure to be removed.
- GC shall take precautionary measures to protect existing house during construction.

GC shall protect existing plants and grass during construction. Reseed disturbed grass areas.
ROOM SIGN W/ 3" HIGH
TACTILE LETTERS &
5. BRAILLE FOR EXITS 1 11/2/2020 For Permit
Owner shall be responsible for providing water and electric at the required work area. SINGLE OR GANG NO. DATE ISSUE NOTE
LIGHT SWITCHES
6.
All work performed as a part of the contract is to be guaranteed by the contractor and/or subcontractor to be free from defects in COUNTER / Project Manager Drawn By
THERMOSTAT, CABINETS OVER 20" DEEP GaL
material and workmanship for a period of one (1) year from the date of completion of work; the contractor and/or subcontractor agrees to Site Plan MECH. OR FIRE
return to the job and make repairs and/or replacement to such defects at no cost to the owner. Final payment shall be made at a Date Reviewed By
Scale: 1" = 30'-0" ALARM CONTROLS ABOVE COUNTER
substantial completion, less the value of the final punch list. Punch list value will be paid at the completion of work. General Contractor June 2020 GaL
shall turn over to owner all documents, manuals, guarantees, etc for all devices, equipment and appliances. ELEC. OUTLETS,
SWITCHES, ETC. Project ID

7. Fellowship Church_Proposed
Each Contractor/Sub-contractor shall file for necessary building permits. The Owner shall be responsible for the cost of the permits.

80" MAX.
Sheet Title
F.E.

3'-3 15/16"
4'-0"

3'-8"
2'-10"
48" MAX.

27" MIN.
HEIGHT TO Cover Sheet

1'-6"
HANDLE

COMPUTER /
DUPLEX OR QUAD * DIMENSIONS ARE TO THE HIGHEST Sheet No.
TELEPHONE JACKS
OUTLET OPERABLE PART OF DEVICE
TYPICAL ADA MOUNTING HEIGHTS
Scale: 3/8" = 1'-0" A0.1
NOTE: B EXIST. CMU WALLS B
FINISHED CEILING AT TO BE PAINTED
THIS ROOM TO BE 41'-5 1/2" 25'-5 1/2"
INSTALLED AT A

A
FUTURE PHASE LINE OF FUTURE

B
16'-8"
B05 BO4 PARTITION B05 NOTE: BO4
Storage Classroom Storage THIS ROOM TO BE Classroom
INTERIOR SIDE OF FINISHED AT A FUTURE
Net Area: 691 sq ft Net Area: 417 sq ft

W-01

W-01
WALL TO BE LEFT PHASE
OPEN AND FINISHED All drawings and written
IN THE FUTURE A A materials appearing herein
EXIST. STAIR EXIST. STAIR constitute original and
unpublished work of the
05 04 03
architect and may not be used
or disclosed without prior
B06 B06 consent of 4/4 Architecture, LLC
NOTE: EXIST. WINDOWS Copyrighted 2020
Hallway 'A' Hallway 'A' TO BE REMOVED
A PROVIDE &
Net Area: 187 sq ft INSTALL NEW WHERE TAGGED.
PLASTIC LAMINATE PROVIDE & INSTALL

W-01

W-01
05 NEW CASEMENT

Whitehall Bible Fellowship Church


SILLS W/ GYP. BD.
FINISH EXPOSED RETURNS AT EACH WINDOWS.
GYP. BD. SOFFIT INTERIOR SIDE OF COLUMN W/ GYP. WINDOW
@ EXIST. BEAM WALL TO BE LEFT 02
BD., PAINTED, TYP.
OPEN AND FINISHED IN
THE FUTURE
LINE OF FUTURE

35'-8"
07

3300 7th St, Whitehall, PA 18052, USA


NOTE: PARTITIONS
FINISHED CEILING AT
THIS ROOM TO BE 26'-0" 31'-0" 20'-0"
2

W-01

W-01
INSTALLED AT A

A
A1.1

Basement Fit-out
FUTURE PHASE
B02 B02
B10 B10
Classroom Classroom
Open Area/ Flex Space Open Area/ Flex Space

37'-1 1/2"
Net Area: 697 sq ft
B07 B07 Net Area: 1402 sq ft
Storage Storage

B
Net Area: 963 sq ft

A
A

W-01

W-01
NOTE: LINE OF GYP. BD.
GYP. BD. SOFFIT THIS ROOM TO BE SOFFIT ABOVE 01 EXISTING PAIR
NOTE: @ EXIST. BEAM FINISHED AT A FUTURE 6'-0" OF EGRESS
FINISHED CEILING AT PHASE INSTALL TYPE DOORS W/
2A FIRE
THIS ROOM TO BE B01 NEW MECH. CLOS.
11 EXTINGUISHER IN
B01 EXIST. PANIC

10'-0"
INSTALLED AT A 08 HARDWARE &
FUTURE PHASE Hallway 'B' SEMI RECESSED Hallway 'B' CLOSER
EXIST. WALL CABINET
A CONSTRUCTION TO
Net Area: 202 sq ft

3'-6"
BE PAINTED TS-1
06
B09 B09
Hallway 'C' Hallway 'C'
31'-1 1/2" Net Area: 211 sq ft
B08 EXIST. EQUIP; EXIST. MECH. B08 EXIST. EQUIP; EXIST. MECH.
BFC Historical Archives BFC Historical Archives 09

Net Area: 483 sq ft

15'-6 1/2"
FUT. MACH. FUT. MACH.

Project Title
EXIST. STAIR EXIST. STAIR

Basement Reflected Ceiling PLan


Scale: 1/8" = 1'-0"
NOTE:
THIS DWG. PROVIDED FOR COORDINATION PURPOSES
ONLY. REFER TO MECHANICAL & ELECTRICAL DWG'S
Basement Plan - Proposed
PREPARED BY LIBERTY ENGINEERING FOR FULL SCOPE Scale: 1/8" = 1'-0"
OF WORK.

SYMBOL DESCRIPTION WALL TAG DESCRIPTION

2x4 LIGHT FIXTURE 5/8" GYP. BD. (GREEN BD. AT WET LOCATIONS) BOTH
A
SIDES OF 2X4 WOOD STUDS @ 16" O.C. TO UNDERSIDE
HVAC RETURN AIR OF EXIST. JOISTS W/ FULL THICKNESS SOUND
ATTENUATION BLANKETS.

HVAC SUPPLY AIR 1. ALL NEW FLOORING TO BE VCT AS SELECTED


5/8" GYP. BD. (GREEN BD. AT WET LOCATIONS) ONE 2. ALL WALLS TO BE PAINTED. WALLS TO RECEIVE RUBBER COVE
B BASE. COLORS AS SELECTED.
EMERGENCY EXIT DEVICE SIDE OF 2X4 WOOD STUDS @ 16" O.C. TO UNDERSIDE
OF EXIST. JOISTS W/ R11.4 CONTINUOUS RIGID
INSULATION AT INTERIOR SIDE OF EXIST. CMU
EMERGENCY EXIT DEVICE EXTERIOR WALL
W/ DIRECTION ARROWS

1/4" TEMP.
GLASS VISION
PANEL
3'-0" 2" 3'-0" 2" 2" 3'-0" 2" 2" SEE SCHEDULE 2"
M.O.
2"

2"

2"

NEW CASEMENT
WINDOW, BASIS OF Door Schedule REV. DATE DESCRIPTION
4'-5 1/2"

2'-6"

DESIGN: ANDERSEN
Nominal Size Door Style Door Frame Fire Rating
M.O.

H.M. FRAME,
SERIES 400 W/ LOW E
PAINTED, TYP.
INSULATED GLASS,
6'-8"

6'-8"

6'-8"

FINISH AS SELECTED
6"
BY OWNER

Jamb Depth
Jamb Thick
Glaz. Style
SOLID WOOD

Thickness

Door Slab
DOOR,

HW Set
Height

Frame
STAINED, TYP.

Width
W-01 Elevation A B C Mark Configuration Door Elevation Comments 1 11/2/2020 For Permit
2 01 3'0" 6'8" 1 3/4" Swing Simple B Temp 2" 4 3/4" - - Classroom
Scale: 1/4" = 1'-0" NO. DATE ISSUE NOTE
DOOR ELEVATIONS 02 3'0" 6'8" 1 3/4" Swing Simple B Temp 2" 4 3/4" - - Classroom
1
Scale: 1/4" = 1'-0" 03 3'0" 6'8" 1 3/4" Swing Simple B Temp 2" 4 3/4" - - Classroom Project Manager Drawn By

03 3'0" 6'8" 1 3/4" Swing Simple B Temp 2" 4 3/4" - - Classroom GaL
04 6'0" 6'8" 1 3/4" Swing Bi-part C None 2" 4 3/4" - - Lockset Date Reviewed By

05 6'0" 6'8" 1 3/4" Swing Bi-part C None 2" 4 3/4" - - Lockset June 2020 GaL
NOTE: 1'-0" 6" Project ID
05 6'0" 6'8" 1 3/4" Swing Bi-part C None 2" 4 3/4" - - Lockset
18" CLEAR Fellowship Church_Proposed
DIMENSION ON 06 3'0" 6'8" 1 3/4" Swing Simple A None 2" 4 3/4" - - Lockset
PULL SIDE AND 12" 06 3'0" 6'8" 1 3/4" Swing Simple A None 2" 4 3/4" - - Lockset Sheet Title
CLEAR DIMENSION C 07 3'0" 6'8" 1 3/4" Swing Simple A None 2" 4 3/4" - - Lockset
L
ON PUSH SIDE AS
REQUIRED PER 08 6'0" 6'8" 1 3/4" Swing Bi-part C None 2" 4 3/4" - - Lockset
ANSI A117.1 09 3'0" 6'8" 1 3/4" Swing Simple B Temp 2" 4 3/4" - - Classroom Basement Floor &
11 5'0" 6'8" 1 3/4" Swing Bi-part C None 2" 4 3/4" - - Lockset Ceiling Plan
1. PROVIDE LEVER TYPE DOOR HARDWARE PER ADA STANDARD, FINISH PER BUILDING STANDARD.
1'-6" 2'-0" 2. ALL DOOR HARDWARE TO BE COMMERCIAL TYPE, SCHLAGE GRADE 2 OR APPROVED EQUAL Sheet No.
3. CONFIRM ALL LOCK FUNCTIONS AND KEYING WITH OWNER.

TYP. DOOR LOCATION


SCALE: 1/4" = 1'-0" A1.1