DESIGN INFERENCE

BHUMIKA BATRA
A1904018036
Op
Neighbouring Area affecting the site

en
Dra
in
l
tia
s i den
Re a
Are

Enc a
Are
roa
ch
ed
School
a
m Are
Slu

2
Najafgarh Nala is at a
distance of 4km from the site

The overall micro climate of


the place is affected due to it

3
Site Entrances
ROAD CROSSING

d
e roa
r wid
ete
12 m

30
me
ter
w
ide
Main Entrance

roa
9m

d
ete

Emergency
rw
ide

Service
roa
d

d
roa Bus Stop
ide
rw
ete
6m

4
There are hardly any
views from the site,
But the school can be the
only direction in which the
building can be oriented
for views.

Noise is a factor that is


observed from all sides of
the Site
NOISE
VIEWS
NOISE

VIEWS

Kendriya
Vidyalaya
School

5
Plantation around the site
to act as a buffer for Noise

Plantation have been


placed such that they don't
block the prevailing winds
and funnel it towards the
Wind building block
Direction

Evergreen Trees

Evergreen
trees spaced
at distance for
shading east
facing wall

6
Majority of Fenestration towards the
Prevailing winds from WNW side following sides for good air circulation
Winds from NNW side as well throughout the building

7
Wind Direction

Wind will be deflected by the


treses to make sure
maximum breeze enters the
building

8
Drainage Pattern

Water clogging in the center


of the site could be a
problem

To avoid that,
1 Filling and levelling of site
2 Drainage channels to be
+211 placed in a away to avoid
collection of site
+210

Minimum rainfall in the month of December


Maximum rainfall in the month of August

9
SUN ORIENTATION
Since southwest is responsible for maximum
heat gain hence the orientation of the
building block should not be facing it.
The larger profile of the building will be
responsible for max. Heat gain therefore it
should be oriented in a opposite direction.
10
Wind
Directi
on

For passive solar heating face most of the glass area


south to maximine winter sun exposure but design
overhangs to fully shade in summer

11
DESIGN INFERENCE FOR HOT AND DRY CLIMATE

Earth shuttering, occupied basement, or earth tubes


reduce heat loads in very hot dry climate because the
earth stays near average annual temperature
Window overhangs or operable sun shades can Traditional passive method to deal with hot windy
reduce or eliminate air condition climate use shaded courtyard with a small fountain or
water body to regulate the microclimate ( wind
regulated microclimate )

13

Use light coloured building material and cool roofs Provide double pane high performance glazing
(with high emissivity) to minimise connected heat (Low-E) on west,north and east but not on south
gain for maximum passive solar gain

14