Tiles fixed with Water

Resistant Tile Adhesive

See Note 4 Below;

See Note 2 Below;

See Note 3 Below;


See Note 1 Below;

NOTES:

1. To all construction joints apply Vandex Super at 1.5Kg/m² .

2. Apply two coats of Vandex Super, each at 0.75Kg/m² (1.5Kg/m² total) to vertical
surfaces.
3. Apply Vandex Super at 1.2Kg/m² in a single application to horizontal surfaces.

4. To wall and floor surfaces apply a tight rough cast cast of sand/cement mortar
at 3:1 ratio - approx. 5mm (¼") - on top of Vandex Super whilst this is still "green"

NOTES: System Drg. VAND-001(2).tcw (TurboCAD) CLIENT:-


VAND-001(2).dwg (Autocad)
Nos: VAND-001(2).pdf (Acrobat) Safeguard Europe Ltd.
CONTRACT No:

DRAWN JDF, CBS TITLE:


DATE 25th February 2005
Vandex Waterproofing System
SCALE (A3) Not To Scale
Swimming Pool Detail DRG. No. REV
MOD. BY DATE CHK. BY APP. BY MOD. BY DATE CHK. BY APP. BY MOD. BY DATE CHK. BY APP. BY CHECKED With Tiles VAND-001 2
JDF, CBS 03/10/07 APPROVED

Safeguard Europe Ltd, Redkiln Close, Redkiln Way, Horsham, West Sussex, RH13 5QL Tel: 01403 210204 Fax: 01403 217529 www.safeguardeurope.com