BATTERY SPECIFICATION
and APPLICATION GUIDE
2009-2011
HGV
commercial vehicle battery
CXT Gold
calcium sealed battery
MOTORCYCLE
open vent, sealed and gel
Contents
Manbat Ltd reserves the right to alter specification, add or delete battery types without prior notice. Whilst every care has been taken in
compiling the information in this publication, Manbat Ltd cannot accept legal liability for any inaccuracies. All rights reserved. No part of
this publication may be reproduced, stored in a retrieval system, or transmitted in any form, or by any means, electronic mechanical,
photocopying or otherwise without prior permission of Manbat Ltd.
2
PRODUCT FEATURES
Battery specifications
Notes Layouts
1 Battery with handles 6 Volt
2 Battery with 2 base hold downs 29mm high on short
sides (B9)
3 Battery with 2 base hold downs 19mm high on long
sides (B4) 0 1 2 3 4 5 6 7
4 Battery with 2 base hold downs 10.5mm high on 12 Volt
long sides (B1)
5 Battery with 4 base hold downs 10.5mm high on
long and short sides (B3)
6 Battery with 2 base hold downs 10.5mm high on
long sides and 2 base hold downs 29mm high on Terminals
short sides (B5)
7 Battery with base hold downs 10.5mm high on long
and short sides with 5 indentations on long sides for
clamping (B13)
8 Battery with base hold downs 19mm high on long
and short sides with 5 notches on long sides for
clamping (B14) 1 2 3 8 10 19
9 Battery for breather for remote venting taper motorcycles small UTL dual post lug
taper terminal
10 Semi-traction (for standard and heavy cyclic
applications)
11 Heavy duty (incorporates semi-traction and additional Accessories
vibration proof features)
17 Battery fitted with 'magic eye' hydrometer The following accessories are available from Manbat.
For more details, ask your area manager or the Manbat sales team.
19 Battery supplied with adaptor, therefore suitable for
fitment with Japanese types listed. Please note
Description Part No.
change in dimensions when using adaptor
20 Battery fitted with central gassing. Please allow 7- Ford terminal adaptor kit SAP537272
10mm extra VW/Audi Holddown Adaptor SAP537267
Terminal sleeves (set) SAP537270
21 Leisure (for light cyclic applications)
Terminal Adaptor positive terminal 1 100 01
24 LF Technology Terminal adaptor negative terminal 2 100 01
26 Low maintenance Hydrometer 0 059 00
Midtronics Tester 834263001
Motorcycle hydrometer 833841001
Neutralon spray 883256001
Wilkson battery tester 884000001
Wilkson voltmeter 884002001
Battery stand Batstand
Acid Pack Acid 6
Powakaddy connector for 26Ah battery PK18
Powakaddy connector for 34Ah battery PK36
Powakaddy T piece connector PKT
Hill Billy connector with Torberry HBC
Base hold-downs
B3 B9
B1
B4 B11
B6 B13
B7 B14
6
ge
ion
ate
PS har
0H h.
sit
ls
g
rt
r. r
@2 nA
nt r
)K
AM ch c
Part No. JIS Ref. Dimensions Notes
ina
EN sta
ve the
po
ix
f
(fil ght
ut
Re
uif
led
pi
L W H
rm
yo
ea
ld
i
UK
We
Liq
Ca
Co
Be
La
Te
Br
(mm) (mm) (mm)
6 Volt
002014001 6N2A-2C-3 819 RIGHT 2 10 1.0 71 47 106 0.6 0 2 9,20,26
004012001 6N4B-2A, 6N4B-2A-3 842 LEFT 4 10 1.0 102 48 96 1.0 1 2 9,19,20,26
004013001 6N4A-4D 839 BEHIND 4 10 1.0 57 61 131 0.8 3 2 9,20,26
004014001 6N4-2A-1, 6N4-2A-4, 6N4A-2A-7 837 LEFT 4 10 1.0 71 71 96 0.9 1 2 9,19,20,26
004015001 6N4C-1B - RIGHT 4 10 1.0 71 71 105 1.2 0 2 9,20,2
006011003 6N6-3B 852 ON TOP 6 30 1.0 100 57 111 1.3 2 2 9,20,26
006012003 6N6-3B-1 - RIGHT 6 30 1.0 99 57 111 1.3 2 2 9,20,26
006013003 6N6-1D-2 - BEHIND 6 30 1.0 100 58 112 1.3 0 2 9,26
007014003 B39-6 802 7 30 1.0 129 52 128 1.6 0 2 9,26
008011004 B49-6 - 8 40 1.0 95 85 166 2.2 1 2 9,26
011400008 6N11A-1B - RIGHT 11 80 1.0 122 62 132 2.2 2 2 9,20,26
012014008 6N11A-3A 859 LEFT 12 80 1.0 123 61 137 2.3 3 2 9,20,26
012025008 6N12A-2D - BEHIND 12 80 1.0 156 57 116 2.4 1 2 9,26
016012008 B38-6A - 16 80 1.0 122 82 165 2.5 2 2 9, 20, 26
12 Volt
503011001 YB2.5L-C-2 - FRONT 2.5 10 1.0 81 71 106 1.0 0 2 9,20,26
503012001 YB3L-A - LEFT 3 10 1.0 100 58 112 1.3 0 2 9,20,26
503013001 YB3L-B - RIGHT 3 10 1.0 100 58 112 1.3 0 2 9,20,26
503014003 YT4L-BS - • SEALED 3 30 1.0 104 71 106 1.4 0 2 24
503902004 YT4B-4,YT4B-BS - • SEALED 3 40 1.0 114 49 86 1.6 4 Push On 24
503903004 YTR4A-BS - • SEALED 3 40 1.0 114 49 86 1.8 4 2 24
504011002 YB4L-B - RIGHT 4 20 1.0 121 71 93 1.5 0 2 9,20,26
504012003 YTX5L-BS - • SEALED 4 30 1.0 114 71 106 1.9 0 2 24
505012003 YB5L-B, 12N5-3B 864 RIGHT 5 30 1.0 121 61 131 2.0 0 2 9,20,26
505901009 YTZ6S-BS - • SEALED 5 90 1.0 113 70 105 4.2 0 2 24
506011004 12N5.5-3B 866 RIGHT 6 40 1.0 136 61 131 2.4 0 2 9,20,26
506012004 12N5.5A-3B 870 RIGHT 6 40 1.0 104 91 115 2.4 0 2 9,20,26
506014005 YTX7L-BS - • SEALED 6 50 1.0 114 71 131 2.5 0 2 24
506015005 YTX7A-BS - • SEALED 6 50 1.0 151 88 94 2.6 1 2 24
507012004 YB7L-B, 12N7-3B - RIGHT 7 40 1.0 136 76 135 3.0 0 2 9,20,26
507013004 12N7-4A - LEFT 7 40 1.0 136 76 135 3.0 1 2 9,20,26
507101008 YB7C-A RIGHT 7 8 1.0 130 90 114 2.3 0 2 9,20,26
507901012 SEALED 7 120 1.0 150 66 94 2.7 1 2 24
507902011 YTZ7S, YTZ7S-BS - • SEALED 7 110 1.0 113 70 105 4.9 1 2 24
508012008 YTX9-BS • SEALED 8 80 1.0 152 88 106 3.0 1 2 24
508013008 YB7-A - LEFT 8 80 1.0 137 76 134 3.0 1 2 9,20,26
508901015 YTZ10S, YTZ10S-BS - • SEALED 8 150 1.0 150 87 93 5.2 1 2 24
509014008 YB9-B, 12N9-4B-1 885 RIGHT 9 80 1.0 136 76 140 3.2 1 2 9,20,26
509015008 YB9L-B, 12N9-3B 868 RIGHT 9 80 1.0 136 76 140 3.2 0 2 9,20,26
509016008 YB9L-A2 - LEFT 9 80 1.0 135 75 139 3.1 0 2 9,20,26
509901020 YTZ12S-4, YTZ12S-BS - • SEALED 9 200 1.0 150 87 110 5.8 1 2 24
509902008 YT9B-4, YT9B-BS - • SEALED 9 80 1.0 149 70 105 2.7 1 2 24
510012009 YTX12-BS • SEALED 10 90 1.0 152 88 131 4.2 1 2 24
510901012 YTR9-4, YTR9-BS - • SEALED 10 120 1.0 150 87 105 3.8 1 2 24
511012009 YB10L-A2,12N10-3A 890 LEFT 11 90 1.0 136 91 147 4.8 0 2 9,20,26
511013009 YB10L-B2, YB10L-B, 12N10-3B - RIGHT 11 90 1.0 136 91 146 4.6 0 2 9,20,26
511901014 YT12A-4, YT12A-BS - • SEALED 11 140 1.0 150 88 105 4.1 1 2 24
511902023 YTZ14S-4, YTZ14S-BS - • SEALED 11 230 1.0 150 87 110 6.4 1 2 24
512011012 YB12A-A, 12N12A-4A-1 897 LEFT 12 120 1.0 136 81 142 4.2 1 2 9,20,26
512012012 YB12B-B2 - RIGHT 12 120 1.0 161 91 131 4.0 1 2 9,20,26
512013012 YB12AL-A, YB12AL-A2 - LEFT 12 120 1.0 136 82 162 5.0 0 2 9,19,20,26
512014010 YTX14-BS - • SEALED 12 100 1.0 152 88 147 4.6 1 2 24
512015012 YB12A-B - RIGHT 12 120 1.0 136 82 162 4.1 1 2 9,20,26
512901019 SEALED 12 190 1.0 151 70 131 4.1 1 2 24
512903013 YT14B-4, YT14B-BS - • SEALED 12 130 1.0 152 70 150 5.5 1 2 24
514011014 YB14L-A2, 12N14-3A 898 LEFT 14 140 1.0 135 90 167 4.6 0 2 9,20,26
514012014 YB14-A2 - LEFT 14 140 1.0 136 91 168 4.5 1 2 9,20,26
514013014 YB14L-B2 - RIGHT 14 140 1.0 136 91 168 4.5 0 2 9,20,26
514014014 YB14-B2 - RIGHT 14 140 1.0 136 91 168 4.5 1 2 9,20,26
514400019 YB14L-A1 - LEFT 14 140 1.0 135 91 167 5.8 0 2 9,20,26
514901022 YTX16BS-1 - SEALED 14 220 1.0 150 87 161 4.7 0 2 24
514902022 YTS16BS - SEALED 14 220 1.0 150 87 161 4.7 1 2 24
516015016 YB16B-A, YB16B-A1 - LEFT 16 160 2.0 160 90 161 5.0 1 2 9,19,20,26
516016012 YB16AL-A2 - LEFT 16 120 2.0 207 72 164 5.3 0 2 9,20,26
518014015 BMW ONLY - RIGHT 18 150 2.0 186 82 173 8.0 0 2 9,20,26
518015018 YB18L-A - LEFT 18 180 2.0 181 92 164 7.2 0 2 9,20,2
518400018 YB18-A - LEFT 18 180 2.0 181 92 164 7.2 1 2 9,20,26
518901026 YTX20L-BS - SEALED 18 260 2.0 177 88 156 7.8 0 2 24
518902026 YTX20-BS - SEALED 18 260 2.0 177 88 156 7.8 1 2 24
518903020 CP18-12 - • 18 200 2.0 181 76 167 7.9 1 2 24
519011019 YB16L-B 103 RIGHT 19 190 2.0 176 101 156 6.3 0 2 9,20,26
519012019 YB16-B - RIGHT 19 190 2.0 176 101 156 6.3 1 2 9,20,26
519013017 BMW ONLY - LEFT 19 170 2.0 186 82 171 6.0 0 2 9,20,26
519014018 YB16CL-B - RIGHT 19 180 2.0 176 101 176 6.3 0 2 9,20,26
519901017 - AGM 19 170 2.0 186 82 173 8.0 1 2
520012020 Y50-N18L-A, Y50N-18L-A2 - LEFT 20 200 2.0 206 92 163 7.0 0 2 9,20,26
520016020 SY50-N18L-AT - LEFT 20 200 2.0 206 91 170 6.5 0 2 9,20,26
520400026 12N20AH - RIGHT 20 260 2.0 186 81 170 7.4 0 2 9,20,26
520401026 Y50-N18L-A3 - LEFT 20 260 2.0 206 91 164 7.4 0 2 9,20,26
524101020 12N24-4, 896 RIGHT 24 300 3.0 186 130 171 10.0 1 2
525015022 Y60-N24L-A - RIGHT 25 220 2.0 186 130 171 10.0 0 2 9,20,26
528400030 Y60-N24AL-B - RIGHT 28 300 3.0 185 125 176 10.0 0 2 9,20,26
530030030 YB60-N24L-A, B68-12, BMW 895 RIGHT 30 300 3.0 186 130 171 10.0 0 2 9,20,26
532011024 - 32 240 3.0 233 132 168 8.2 1 2 9, 20, 26
532036024 YHD-12 - LEFT 32 240 3.0 243 132 165 8.3 1 2 9,20,26
8
RESQPAC12 12 3200
RESQAUTO12 12 1600
RESQPAC12/24 12/24 7000 3500
RESQPAC24 24 1600
RESQPACEURO12/24 12/24 3200 1600
VRLA
SLA2.1-6 6 2.1 97 25 55 0.30
SLA2.8-6 6 2.8 134 34 64 0.56
SLA4-6 6 4 70 47 106 0.85
SLA7-6 6 7 151 34 98 1.30
SLA12-6 6 12 151 50 98 2.01
SLA33-6 6 33 180 76 167 5.90
SLA1.2-12 12 1.2 97 48 55 0.57
SLA2.3-12 12 2.3 178 34 64 0.95
SLA2.9-12 12 2.9 79 56 105 1.10
SLA3.2-12 12 3.2 134 67 64 1.18
SLA4.5-12 12 4.5 90 70 106 1.79
SLA5-12 12 5 140 48 103 1.65
SLA7-12 12 7 151 65 98 2.30
SLA10-12 12 10 151 65 117 2.90
SLA12-12 12 12 151 98 98 4.05
SLA20-12 12 20 180 76 167 6.28
VRLA CYCLIC
SLC200-6 6 200 243 187 276 32.00
SLC18-12 12 18 180 76 167 6.20
SLC22-12 12 22 180 76 167 6.45
SLC26-12 12 26 166 175 125 9.20
SLC34-12 12 34 196 130 168 11.40
SLC42-12 12 42 197 165 170 14.50
SLC65-12 12 65 350 167 186 23.20
SLC75-12 12 75 260 168 233 24.00
SLC85-12 12 85 260 168 233 25.50
SLC120-12 12 120 409 176 225 35.50
SLC150-12 12 150 485 172 240 50.00
SLC160-12 12 160 341 173 308 52.00
SLC180-12 12 180 494 206 209 56.00
SLC200-12 12 200 522 238 218 61.50
SLC260-12 12 260 521 269 220 79.00
GEL
SLG200-6 6 200 243 187 276 28.50
SLG7-12 12 7 151 65 98 2.35
SLG26-12 12 26 166 175 125 9.30
SLG34-12 12 34 196 130 168 11.50
SLG42-12 12 42 197 165 170 14.60
SLG63-12 12 63 260 168 233 23.00
SLG75-12 12 75 260 168 233 24.30
SLG104-12 12 104 330 171 224 31.50
SLG140-12 12 140 342 172 280 45.00
SLG180-12 12 180 494 206 280 103.00
SLG200-12 12 200 522 238 220 105.00
SLG250-12 12 250 521 269 220 108.00
Accessories
Description Part No.
Powakaddy connector for 26Ah Battery PK18
Powakaddy connector for 34Ah Battery PK36
Powakaddy T piece connector PKT
Hill Billy connector with Torberry HBC
11
VRLA batteries
The YUASA range of batteries extends to far more than mobility, emergency lighting and alarms.
YUASA EN & ENL ENDURANCE RANGE – Built for large standby applications such as
Telecommunications and UPS.
YUASA NPL RANGE – An enhanced NP design for a longer service life (7-10 years).
YUASA SW SERIES – Based on the NPL range but with up to 40% extra discharge capacity.
YUASA NICKEL CADMIUM (NiCd) Cylindrical cells – Built in different configurations for
emergency lighting units.
YUASA NICKEL METAL HYDRIDE (NiMH) Cylindrical cells – Available in different sizes and
configurations for rechargeable applications.
YUASA NPC RANGE – Suited for Arduous Cyclic Applications (Mobility and Golf)
NPC8-6 6 8.0 151 50 97.5 1.80
NPC17-12 12 17.0 181 76 167 6.10
NPC24-12 12 24.0 166 175 125 9.00
NPC30-12 12 30.0 195 129 179 11.2
NPC38-12 12 38.0 197 165 170 14.2
NPC65-12 12 65.0 350 166 174 23.0
GEL batteries
SOLAR – 12 volt blocks from 6.6Ah to 230Ah. This is an extremely powerful battery which is reliable in rough application conditions.
POWERFIT – The S500 AGM range with 6volt and 12 volt blocks ranging from 1.2Ah to 40Ah. For smaller general applications and emergency
lighting.
MARATHON – 2volt. 6 volt and 12 volt blocks with a 12 year design life for heavy duty standby applications. Telecommunications, Railway, and
Safety Power Supplies.
SPRINTER – 6 volt and 12 volt blocks with high current discharge characteristics. Ideal for UPS systems with it’s low self discharge rates
ABSOLYTE – The original 20 year life stationary battery. With capacities ranging from 100Ah to 6000Ah.
CLASSIC – The traditional vented lead acid battery in 2volt, 6 volt or 12 volt blocks. Low maintenance 12 year design life with a nominal range
from 28Ah to 1600Ah. Used in UPS, Telecom and Emergency Lighting.
Odyssey
PRODUCT FEATURES
Type Voltage CCA* Pulse Current Ah@20hr Reserve Dimensions Weight Terminal Layout
AMPS rate capacity L (mm) W (mm) H (mm) Kg
Optima
Type VB UK No. Voltage CCA EN Ah@20hr Reserve Weight Dimensions Terminal Layout
short code rate capacity Kg L (mm) W (mm) H (mm)
OPTIMA RANGE
REDTOP - Starting
RTS2.1 810-355 6 815 50 110 8.3 252 90 206 Post Central
RTS3.7 820-255 12 730 44 90 14.4 237 172 197 Post 1
RTR3.7 835-255 12 730 44 90 14.4 237 172 197 Post 0
RTU3.7 822-255 12 730 44 90 15 237 172 191 Post 1
RTC4.2 801-287 12 815 50 100 17.2 254 175 200 Post Central
RTS4.2 802-250 12 815 50 100 17.2 254 175 200 Post Central
RTR4.2 803-251 12 815 50 100 17.2 254 175 200 Post Central
RTU4.2 804-250 12 815 50 100 17.6 254 175 200 Post 1
RTV4.2 808-250 12 815 50 100 17.6 254 175 200 Post Central
YELLOWTOP - Dual Power
YTS2.1 818-356 6 765 55 120 9.5 254 90 203 Post Central
YTR2.7 873-176 12 460 38 66 11.8 237 129 227 Post 1
YTS2.7J 870-176 12 460 38 66 11.8 237 129 227 Narrow Post 0
YTR2.7J 872-176 12 460 38 66 11.8 237 129 227 Narrow Post 1
YTS2.7 871-176 12 460 38 66 11.8 237 129 227 Post 0
YTR3.7 840-222 12 660 48 98 16.6 237 172 197 Post 0
YTS4.2 812-254 12 765 55 120 19.5 254 175 200 Post Central
YTU4.2 814-254 12 765 55 120 19.9 254 175 200 Post 1
YTS5.5 851-187 12 975 75 155 27.1 324 165 238 Post Central
BLUETOP - Marine
BTDC 4.2 816-253 12 765 55 120 19.7 254 175 200 Post & Thread 1
BTSLI4.2 806-252 12 815 50 100 17.4 254 175 200 Post & Thread 1
BTDC5.5 852-188 12 975 75 155 26.5 325 165 238 Post & Thread 7
TROLLFURY 988-112 CARRIER FOR 2 X BTDC4.2 BATTERIES 581 213 213
16
Some vehicles with added electrics such as air conditioning have larger capacity batteries fitted as O.E., Check original battery fitment
21
Some vehicles with added electrics such as air conditioning have larger capacity batteries fitted as O.E., Check original battery fitment
22
Some vehicles with added electrics such as air conditioning have larger capacity batteries fitted as O.E., Check original battery fitment
23
Some vehicles with added electrics such as air conditioning have larger capacity batteries fitted as O.E., Check original battery fitment
24
Some vehicles with added electrics such as air conditioning have larger capacity batteries fitted as O.E., Check original battery fitment
25
JEEP LANCIA
Petrol BETA Coupe Spider, HPE 75- 063 063 065
CJ/YJ Petrol - 053 - 048H BETA Saloon 75- 077 - 078
CHEROKEE 2.5, 4.0 84- 096R - - DEDRA 94- 027 075 075
COMMANDER 3.7,4.7,5.7 05- 096 096 017 DELTA 80- 077 - -
COMPASS DELTA Turbo 84-86 077 - -
GRAND CHEROKEE 4.0, 4.7, 5.2 92- 096R - - FULVIA 75- 077 - -
V8 Petrol - 069 069 072 GAMMA Saloon, Coupe 76-84 069 069 089
PATRIOT MONTECARLO 77-85 077 - -
WRANGLER 2.5 93 AM058R - - KAPPA 94-01 027 075 075
WRANGLER 4.0 87- 096R - - LYBRA 99- 027 075 075
Diesel MUSA 04- 027 075 075
CJ/YJ Diesel - 644 - 664 PRISMA 83-91 063 063 065
CHEROKEE 2.5D 89- 069 069 072 THEMA, PHEDRA 85- 096 096 100
GRAND CHEROKEE 2.5D, 3.1TD 95- 069 069 072 THESIS 02- 017 017 019
TREVI 81-84 077 - 078
JENSEN Y and Y10 85-91 063 063 063
CABRIO - 069 069 072 Y10 Turbo 85-88 077 - -
COUPE - 069 069 072 YPSILON 03- 027 075 075
HEALEY - 057 - -
INTERCEPTOR - 069 069 072 LAND ROVER
S-V 8 00- 069 069 072 Petrol
DISCOVERY Petrol 89- 069 069 072
KIA DISCOVERY III 04- 017 017 019
Petrol FREELANDER Petrol 97- 027 075 075
CARENS 2.0 00- 065 075 075 RANGE ROVER Petrol 70-94 069 069 072
CARENS III 06- 027 075 075 RANGE ROVER Petrol 94-00 069 069 072
CARNIVAL 01- 005L - 068 RANGE ROVER Petrol 01- 020 - 610200
CEE’D 07- 068 - 249 RANGE ROVER SPORT 05- 019 017 017
CERATO 04- 027 075 075 DEFENDER Petrol 90- 069 069 072
CLARUS 027 075 075 LAND ROVER Petrol 58-83 069 069 089
JOICE 00- 069 069 089
Some vehicles with added electrics such as air conditioning have larger capacity batteries fitted as O.E., Check original battery fitment
26
Some vehicles with added electrics such as air conditioning have larger capacity batteries fitted as O.E., Check original battery fitment
27
Some vehicles with added electrics such as air conditioning have larger capacity batteries fitted as O.E., Check original battery fitment
28
Some vehicles with added electrics such as air conditioning have larger capacity batteries fitted as O.E., Check original battery fitment
29
Some vehicles with added electrics such as air conditioning have larger capacity batteries fitted as O.E., Check original battery fitment
30
Some vehicles with added electrics such as air conditioning have larger capacity batteries fitted as O.E., Check original battery fitment
31
Some vehicles with added electrics such as air conditioning have larger capacity batteries fitted as O.E., Check original battery fitment
32
Some vehicles with added electrics such as air conditioning have larger capacity batteries fitted as O.E., Check original battery fitment
33
Some vehicles with added electrics such as air conditioning have larger capacity batteries fitted as O.E., Check original battery fitment
34
Some vehicles with added electrics such as air conditioning have larger capacity batteries fitted as O.E., Check original battery fitment
35
Some vehicles with added electrics such as air conditioning have larger capacity batteries fitted as O.E., Check original battery fitment
36
Agricultural vehicles
Make and model UK ref Alt part No. Make and model UK ref Alt part No.
Agricultural vehicles
Make and model UK ref Alt part No. Make and model UK ref Alt part No.
Agricultural vehicles
Make and model NUMAX Alt part No. Make and model NUMAX Alt part No.
Agricultural vehicles
Make and model NUMAX Alt part No. Make and model NUMAX Alt part No.
Agricultural vehicles
Make and model NUMAX Alt part No. Make and model NUMAX Alt part No.
SCHMIDT
SKS 150 017 019
SK310 096 100
VF311, HF2 637x2 612x2
KAWASAKI
80cc
KSF80-A YTX5LBS 504012003 YTX5L-A
220cc
KLF220-A YB14AA2 514012014 YB14A-A2
250cc
KLF250 Bayou YB14AA2 514012014 YB14A-A2
300cc
KEF300, KAF300 Mule YB14AA2 514012014 YB14A-A2
KVF300 YB16CLB 519014018 YB16CL-B
400cc
KLF400, KVF400, YB16CLB 519014018 YB16CL-B
KSF400-A (KFX400) YTX9BS 508012008 YTX9-4
KVF400-C, -D YB14AA2 514012014 YB14A-A2
450-620cc
KAF450, KAF540, KAF620 YB16CLB 519014018 YB16CL-B
66
Jet skis
Make and model NUMAX Din No. O.E. or other Make and model NUMAX Din No. O.E. or other
AQUA-Jet
All Models YB16B 519012019 YB16-B
BOMBARDIER
All Models 1988-1993 YB16LB 519011019 YB16L-B
All Models 1994-2003 YB16CLB 519014018 YB16CLB
GTX4-Tec YB30CLB - -
FAZER
All Models YB16B 516015016 YB16B-A1
HONDA
Aqua Trax F-12X, F-12 YTX20LBS 518901026 YTX20L-BS
KAWASAKI
J300 TS, SX YB16CLB 519014018 YB16CL-B
JS400, JS440,
JS550 up to 1986 YB16LB 519011019 YB16L-B
JS440, JS550, SX YB16CLB 519014018 YB16CL-B
JS650TS 1987 on YB16CLB 519014018 YB16CL-B
JF650 Range. JH750 Range YB16CLB 519014018 YB16CL-B
JH750ST, JH750 Zxi YTX20LBS 518901026 YTX20L-4
JS750 Sxi YTX20LBS 518901026 YTX20L-4
JT750 XiR, ST, STS YB16CLB 519014018 YB16CL-B
JS800, JH900, JT900 STS YTX20LBS 518901026 YTX20L-BS
STX YTX20LBS 518901026 YTX20L-BS
JH1100 Range, JH1200 YTX20LBS 518901026 YTX20L-BS
JT1200 YTX20LBS 518901026 YTX20L-BS
POLARIS
All Models YB16CLB 519014018 YB16CL-B
SEA DOO
All Models YB16CLB 519014018 YB16CL-B
ULTRANAUTICS
Jet Star, Sea Flash, Wet Bike Y60N30LA 525015022 Y60-N24-LA
YAMAHA
Wave Runner Models YB16CLB 519014018 YB16CL-B
ADDITIONS
67
Mobility applications
Manufacturer Model Qty Numax Numax Yuasa Sonnenschein
VRLA Gel VRLA Gel
Mobility applications
Manufacturer Model Qty Numax Numax Yuasa Sonnenschein
VRLA Gel VRLA Gel
This application list is a guide reference only. Check original fitment before fitting replacement batteries. It is possible that higher capacity
batteries may have been fitted to give higher performance.
69
Mobility applications
Manufacturer Model Qty Numax Numax Yuasa Sonnenschein
VRLA Gel VRLA Gel
This application list is a guide reference only. Check original fitment before fitting replacement batteries. It is possible that higher capacity
batteries may have been fitted to give higher performance.
70
GUARANTEE
All automotive batteries are guaranteed against premature
failure due to manufacturing or material defects only.
■ Sulphation
■ Wear and tear
■ Deep cycling
■ Overcharging
■ Physical damage
■ Incorrect application
SATISFACTION – GUARANTEED
71
Manbat lead acid automotive batteries are built to the Wear and Tear
highest standards. They are manufactured, in most cases,
During the charge and discharge cycle, material from the
to correspond with vehicle manufacturer’s requirements
battery plates (active mass) is in motion, through the
and specifications.
electrochemical reaction that produces electricity. Every
time the battery goes through a charge and discharge
Nevertheless, it is important to understand that:-
cycle, a small amount of the active mass is lost from the
plates. Because the ultimate life of a battery depends on
A wet battery is 'alive'. Whether it is in service or in
so many factors, it is impossible to stipulate a
storage it has a finite life span. If stored in a wet (filled)
minimum/maximum life expectancy. This process of
condition all batteries will slowly self-discharge. The
normal ageing through the charge and discharge cycle will
higher the ambient (storage) temperature the greater the
eventually cause the battery to lose capacity, and it will
rate of self-discharge.
come to the point where the battery can no longer start
the vehicle/equipment. This is not a manufacturing fault.
To ensure that batteries are not allowed to discharge to the
point where they are either damaged (sulphated) or so
A battery only has a finite number of cycles (x) it can go
that they are incapable of starting the vehicle or operating
through before it loses its capacity to perform. Vehicles
equipment, regular voltage checks should be made
with high usage such as taxi’s, minicabs, trucks, and buses
(monthly).
will often subject the battery to its x number of cycles but
over a much shorter time. As a result, batteries on these
Batteries with a voltage of 12.4v or below should be
vehicles can display the above symptoms after 12-24
recharged. Recharging must not be effected by means of a
months. This is not a manufacturing fault.
rapid charger. Ideally a recharge rate of 1/10th of the
battery’s capacity should be applied for up to 12 hours. At
Deep cycling
the end of this period, a fully charged battery will read
over 12.65v and all cells should be gassing freely. As mentioned above, every time a battery goes through a
Remember if a battery has vent plugs, these should charge and discharge cycle a small amount of the material
always be removed before charging. from the plates is lost. If a battery is subjected to deep
discharging (i.e. over 40%) and then rapid charging, this
process is accelerated. Additionally, if during the recharge
Battery problems – the battery is not adequately compensated for the
discharge cycle, the battery will quickly exhibit loss of
Non-manufacturing faults performance. Even after recharging the voltage will be low
(under 12.4v) but the cells will generally give even
Sulphation readings. This is not a manufacturing fault.
If a battery is allowed to stand in a discharged state for an
excessive amount of time, a chemical reaction takes place, Overcharging
which can permanently impair performance - this is If the regulator is not set properly, then the battery can be
sulphation. Sulphation can be seen as a fine white/grey subjected to an excessive charge. If left unchecked the
coating on the plates. In most cases this signifies battery will overheat and will start to evaporate the
irreversible damage and the battery will not be electrolyte. The overcharging will cause the accelerated
serviceable. This damage can occur either in storage or if break up of the active mass on the plates and the battery
the battery is installed in a vehicle (or equipment) that is will lose performance. This is generally obvious from the
not used for a period of time, for example a tractor, examination of the battery - the acid levels will be very
motorcycle, or boat. Even a car or truck that is stored with low, and quite often a black coating will be visible on the
the battery connected can still damage the battery in this filler caps. This is not a manufacturing fault.
way. This is because there is a permanent drain on the
battery from the clock, alarm etc. As a result the level of Physical damage
charge in a battery falls, and after a period of time
sulphation will build up on the plates. If the battery is fitted incorrectly, if the connector leads are
hammered onto the terminals, or if the leads are not
The sulphation (lead sulphate) hinders the chemical properly fastened, the battery will have obvious damage to
reaction between the acid (electrolyte) and the active mass the casing or the terminals. This is not a manufacturing
(lead compound) in the plates and prevents the battery fault.
from operating as normal. This is not a manufacturing fault.
*Subject to our current sale and warranty conditions (See separate section, 'Manbat Guarantee'), and the preceding test
and recharge procedures.
72
■ Slipping fan belt 7. Hand held testers work by measuring the internal
resistance of a battery using a low alternating current.
■ Electrical fault
Internal resistance can be affected by plate technology,
■ Excessive use of electrical consumers - by the amount of active material left on the plates and
car phones, air conditioning etc by the condition of that active material.
■ Long standing time without recharge 8. A battery that is 2-3 years old may still be serviceable
■ Boot light/glove box malfunction but because of 'wear and tear' may only give a 75%
health reading.
■ Vehicle lights being left on
73
A VISUAL CHECK
1 Does the battery leak? YES NO Continue with A3
Continue with A2
4 Is the battery 12.5 or over? YES NO Battery will require recharging. Then
proceed to B to confirm cell conditions.
Proceed to B to confirm cell conditions.
Recharging - A battery should be capable of accepting a recharge at a minimum of 1/20th of its capacity. ie: 50 Amp Hours = 2.5
Amp charge. The battery should be charged until all cells are gassing freely (maximum 20 hours). If the battery will not accept a
charge at the above rate or if 3 or more cells fail to respond in a prolonged charge, the battery has failed due to aging, wear and
tear or deep cycling discharge. A battery with five cells gassing freely and one/two inert cells will be covered by B1.
4 If the S.G. in all cells is equal or above 1,250 kg/dm3 after charging - proceed to test C.
The lead-calcium-silver technology used in some batteries For details of approved testers please contact the Manbat
means that the conventional filler plugs have been sales office.
replaced by a sealed labyrinth lid, for technical reasons,
and due to consumer demand. In the absence of specialised test equipment many of the
basic steps involved in testing conventional batteries can
The only fully accurate method of evaluating the condition be employed as follows:
and serviceability of ‘sealed’ starter batteries is through
the use of recognised digital electronic test equipment
which, together with a visual inspection will provide an
extremely high level of accurate diagnosis.
A VISUAL CHECK
For battery testers with switchable resistances (Variable Load), discharge the battery at about
3 x the 20hr rate for 10 seconds. (e.g. battery capacity 45 ampere hour (A.H.) = 3 x 45 = 135
amp(s). The voltage during discharge should be stable at 9.6 volts or over.
DIN: Specifies discharge down to 1.5 volts per cell over a period of 30 seconds at -18°C
SAE: Specifies discharge down to 1.2 volts per cell over a period of 30 seconds at -18°C
IEC: Specifies discharge down to 1.4 volts per cell over a period of 60 seconds at -18°C
EN: Specifies discharge down to 1.25 volts per cell over a period of 10 seconds at -18°C
As a result the same battery can have three different ampere ratings for cold starting performance, which means like for like products cannot be
compared easily without knowing which criteria the battery performance is measured against.
In all car and commercial specifications quoted in this catalogue Manbat use the SAE test condition.
75
Handling of Lead Acid Batteries is not hazardous providing Use of Jump Leads
proper precautions are observed.
First connect the positive cable ends to both poles. Then
connect the second cable to the negative battery pole of
Sulphuric Acid
the vehicle to be started and lastly connect the negative
Batteries contain sulphuric acid which may be given off as cable to the negative terminal of the current supplying
droplets or spray during recharging. Sulphuric Acid is vehicle, or even better directly to the engine casing. If in
corrosive and poisonous which can burn/irritate skin and doubt follow the vehicle manufacturers' instructions.
eyes and could burn clothing. Remove cables in the opposite order.
Precautions:
Always handle batteries with care. Always store upright. Weight
Never over fill-with acid. Always remove vent plugs and Batteries can be heavy and awkward to handle. Take care
charge in a well ventilated area. Use eye protection and and use the correct lifting techniques.
protective clothing if there is any risk of acid splashing.
Emergency Action – Skin contact: Disposal
Immediately wash the affected area with copious amounts Used Batteries should be disposed of in a proper manner.
of clean water. See Manbat's environmental policy.
Emergency Action – Swallowing:
Immediately drink large quantities of water or milk. In all Hazardous symbol definitions
cases seek medical attention. 1 Yellow and black explosion triangle
Risk of explosion due to possible build up of hydrogen
Spillages gases. Batteries must be able to vent.
Small spillages can be swilled away with large quantities 2 Red and white 'no smoking' circle
of water. Do not smoke or introduce naked flames near to any
battery. This can cause ignition of hydrogen gases.
Electrical Hazard
3 Blue and white goggles circle
Precautions: Always wear eye protection when charging or testing
Before using metallic tools on a battery remove metallic batteries.
objects from hands and wrists. Before filling or removing
4 Yellow and black corrosion triange
the battery, make sure that all the equipment connected to
Batteries contain sulphuric acid (H2SO4) which is corrosive
it is switched off to avoid accidental sparking. When
to most materials.
undoing the terminal connections, disconnect negative
first and reconnect last. When refitting take care tools do 5 Bin with cross
not cause an accidental short-circuit. Old batteries should not be returned to land fill but must
be disposed of at licensed recyclers.
Explosive gases 6 Recycle sign
The gases given off during charging are explosive. Lead Acid batteries are 100% recyclable.
Precautions: 7 Pb
Always charge in a well ventilated environment. No Batteries contain lead, and lead compounds which are
smoking or naked flames. Ensure that cables and electrical poisonous.
equipment are handled in such a way as to avoid 8 Red circle with children and bar going through
accidental sparking. Always remove negative lead first and Keep batteries away from children. Lead acid batteries are
re-connect last. Use eye protection and protective clothing. a hazard and can be harmful.
Emergency action in case of explosion: 9 Blue circle with book
Seek urgent medical advice remembering that acid may Read all information provided. Coshh sheets are available
have been sprayed. for all products.
Pb
1 2 3 4 5 6 7 8 9
76
Environmental policy
POLICY
ENVIRONMENTAL
MANBAT LTD is committed to the welfare of our shared environment. Working as
we do with potentially unfriendly substances like lead and sulphuric acid it is our
responsibility to ensure that our employees, our customers and our environment
are protected from their harmful effects.
With regard to our employees, health and safety matters are introduced at
induction. Each employee is fully informed about the hazards he or she is likely to
meet in the work environment. Eye Wash Stations and First Aid supplies are
pointed out and demonstrated.
With regard to the environment and in particular the Environmental Protection Act
Manbat Ltd is a Registered Carrier under the Control of Pollution (Amendment) Act
1989. A copy of our registration certificate issued by the Environment Agency is
posted at each Manbat Branch.
Manbat Ltd can collect used batteries from customers whose premises are notified
to the Environment Agency. Specially manufactured bins that hold up to one tonne
of used automotive or industrial batteries can be supplied (ask for cost). Manbat
Ltd can provide you with all the information you need to ensure that you are
operating within the guidelines of the Hazardous Waste Regulations 2005.
Please call us at 01743 460792.
www.manbat.co.uk
NATIONWIDE COVERAGE
NORTH WALES
Unit 1, Expressway Business Park, Abergele Road, Bodelwyddan, Denbighshire, LL18 5SQ
Tel 01745 832174 Fax 01745 833503 Email abergele@manbat.co.uk
SOUTH WEST
Unit 4D, Templegate Distribution Centre, Mead Rise, Bristol, BS3 4RP
Tel 01179 776477 Fax 01179 778481 Email bristol@manbat.co.uk
EAST MIDLANDS
Powermax House, Foxwood Road, Foxwood Industrial Park, Chesterfield, S41 9RN
Tel 01246 452522 Fax 01246 452511 Email chesterfield@manbat.co.uk
SCOTLAND
Unit B, Taywood Enterprise Centre, Duchess Place, Rutherglen, Glasgow, G73 1DR
Tel 0141 647 9700 Fax 0141 647 9740 Email glasgow@manbat.co.uk
SOUTH
Unit 2, Riverside Business Centre, Walnut Tree Close, Guildford, Surrey, GU1 4UG
Tel 01483 504965 Fax 01483 504962 Email guildford@manbat.co.uk
NORTH WEST
Unit 1, Hyde Point, Dunkirk Lane, Hyde, Manchester, SK14 4NL
Tel 0161 351 3580 Fax 0161 351 9981 Email manchester@manbat.co.uk
Longton Battery Services, 259/261 Fylde Road, Ashton on Ribble, Preston, PR2 2NH
Tel 01772 731953 Fax 01772 731953 Email preston@manbat.co.uk
SOUTH EAST
Blue Star House, Shefford Industrial Park, Shefford, Bedfordshire, SG17 5HQ
Tel 01462 851225 Fax 01462 851235 Email shefford@manbat.co.uk