Sie sind auf Seite 1von 3

GULF CABLE & ELECTRICAL INDUSTRIES : ____________

GO

PRODUCT RANGE

We at Gulf Cable always aim for the best. While most of the Cable
Manufacturers in Gulf and Middle East region settled for ISO 9002, we
stand out with ISO 9001 which recognizes our ability for Design &
Development as well.
As a philosophy, our commitment to customers does not end with a sale.
We also offer a host of related services before and after the sale. These
include:

Application Engineering service for selection of appropriate product best suiting the end use.
An extensive range of cables, single core wires, flexible cords, bare & insulated conductors manufactured to stringent
Quality Standards going beyond international specifications.
Design and Development of products tailored to meet specific requirements of the application.
To help the customers understand the product intricacies and its performance levels.

NOTE 1:
The following list tabulates only the "standard" products. For any product not listed below. Please do not hesitate to
contact our sales & marketing division. We shall be too pleased to meet your specific requirements.

NOTE 2:
Voltage Rating.

Two distinct systems of voltage designation are generally in use. Equivalence between these two systems based on
insulation thickness and maximum value of highest system voltage is as tabulated below:

IEC DESIGNATION UO/U (UM) BS DESIGNATION UO/U (UM)

0.6/1 (1.2) KV 600/1000 (1200) V


1.8/3 (3.6) KV 1900/3300 (3600) V
3.6/6 (7.2) KV 3.8/6.6 (7.2) KV
6/10 (12) KV 6.35/11 (12) KV
8.7/15 (17.5) KV 12.7/15 (17.5) KV
12/20 (24) KV 12.7/22 (24) KV
18/30 (36) KV 19/33 (36) KV

WHERE:

UO is rated power frequency voltage between conductor and earth or metallic screen, for which cable is designed.
U is the rated power frequency voltage between conductors, for which the cable is designed.
UM is the maximum value of "highest system voltage" for which the equipment may be used.

From the above tabulation, equivalent iec/bs designation can be determined for any system as appropriate.

NOTE 3:
The following list tabulates only the "standard" products. For any product not listed below, please do not hesitate to
contact our sales & marketing division. We shall be too pleased to meet your specific requirements.

http://www.gulfcable.com/home/range/range.htm[3/13/2011 10:57:41 AM]


GULF CABLE & ELECTRICAL INDUSTRIES : ____________

PRODUCT STANDARD
MEDIUM VOLTAGE POWER CABLES UP TO 30 KV
XLPE insulated, single core or multicore armoured or unarmoured cables IEC 60502 / BS 6622

LOW VOLTAGE POWER CABLES 600/1000 V


PVC Insulated PVC sheathed armoured / unarmoured cables BS 6346 / IEC 502

XLPE insulated PVC sheathed armoured / unarmoured cables BS 5467 / IEC 502

PVC or XLPE insulated PVC sheathed armoured / unarmoured auxiliary cables BS 6346 / BS 5467 / IEC 502

CONTROL CABLES 600 / 1000 V


PVC insulated, shielded or non shielded control cables upto 91 cores BS 6346 / IEC 502

XLPE insulated, shielded or non shielded control cables upto 91 cores BS 5467 / IEC 502

TELEPHONE, COMMUNICATION & INSTRUMENTATION CABLES


PE insulated, star quadded, fully Colour coded telephone cables of armoured, MOC standards
unarmoured or self supporting type
16 core or 34 core pilot cables to be used alongwith underground power lines 11 MEW / ESI Standards
KV, 132 KV and beyond
PE insulated pilot cables ESI Standards

PE insulated communication cables and telemetry cables MEW / ESI Standards

PVC insulated internal telephone cables MOC Standards

Coaxial and data transmission cables Gulf Cable / Customer


Standards
PVC or PE insulated, screened or unscreened, armoured or unarmoured BS 5308 / IEC 502
instrumentation cables
BARE CONDUCTORS FOR OVERHEAD LINES
Aluminium conductors steel reinforced ACSR BS 215 Part 2 / ASTM / CSA /
DIN
All aluminium conductors AAC BS 215 Part 1 / ASTM / CSA /
DIN
Hard drawn bare copper conductors HDBC BS 7884

EARTHING CONDUCTORS
Untinned or tinned bare copper conductors SDBC BS 6360 / IEC 228

PVC OR XLPE INSULATED CONDUCTORS


PVC or XLPE insulated conductors for earthing or overhead lines BS 6485 / Customer Standards

DOMESTIC APPLICATIONS / INTERNAL WIRING


PVC insulated non sheathed single core wires BS 6004 / BS 6231

PVC insulated PVC sheathed single or multicore cables BS 6004

PVC insulated PVC sheathed flexible cords BS 6500 / BS 6141 / BS 6004

PVC insulated PVC sheathed twin flat cables and cords with or without circuit BS 6004
protective conductors (ECC)
PVC insulated parallel twin cords BS 6500

MISCELLANEOUS APPLICATIONS
Welding cables with copper conductor and insulated with rubber based BS 638
compound

http://www.gulfcable.com/home/range/range.htm[3/13/2011 10:57:41 AM]


GULF CABLE & ELECTRICAL INDUSTRIES : ____________

Fire survival cables IEC 502 / IEC 331

Air port lighting cable Customer Standards

Irrigation Cable UL 493

cold pour resin compound and cable joints in the voltage range up to 1000 V AC BS 6910
and 1500 V DC

Gulf Cable© Copyright 2006 - All Rights Reserved

http://www.gulfcable.com/home/range/range.htm[3/13/2011 10:57:41 AM]

Das könnte Ihnen auch gefallen