Document Title Manual – Call Analysis Description
Document Number 16-100-200510
DISCLAIMER: Every effort has been made to ensure the accuracy and completeness in the preparation of this document. However,
should any errors or omissions come to the attention of the user, please contact SwissQual AG. The content of this document is subject
Figures
Fig. 1. Settings Dialog Box ................................................................................................ 6
Fig. 2. The dialog for GSM related thresholds ................................................................... 7
Fig. 3. The dialog for UMTS related thresholds ................................................................. 8
Fig. 4. The dialog for CDMA related thresholds ................................................................. 9
Fig. 5. The dialog for the iDEN receive level threshold ................................................... 10
Fig. 6. The dialog for the IS-136 RxLev threshold .......................................................... 10
Fig. 7. Progress Bar during Call Analysis (only visible if it takes more time) ................. 11
Fig. 8. Call Analysis Report Example ............................................................................... 25
Tables
Tab 1. CallAnalysis Table ................................................................................................. 12
Tab 2. Call Code Description............................................................................................ 17
Once the calls are processed with the procedure ‘sqCallAnalysis’ all relevant data
has been entered into the database (table CallAnalysis) and the recalculation can be
made. With these data the and with respect to the given thresholds (see below) the
code is calculated in the procedure ‘sqCallAnalysisCode’.
The threshold values can be changed at any time. To apply them only push the
recalculation button.
The threshold values can be changed at any time. To apply them only push the
recalculation button.
The threshold values can be changed at any time. To apply them only push the
recalculation button.
During the refresh, the dialog box shows a progress bar and the button
‘Recalculate’ changes to a ‘Cancel’ button.
Fig. 7. Progress Bar during Call Analysis (only visible if it takes more time)
LastHoType Varchar Type of the last Handover before end of the session
(ASS_CMD, ASS_CMPL, ASS_FAIL, HO_CMD,
HO_CMPL, HO_FAIL)
LastHoCause Varchar RR Cause value of the Last HO
avgRLT real Unused
numOfRLTValues int Unused
LastRLTTimeStamp datetime Unused
configCall tinyint Indicates if this was a configuration call (to start or to
stop a scenario)
NumReestablishmentRequests tinyint Number of Call Reestablishment Requests
disconDirection Direction of the DISCON message (U=Uplink,
D=Downlink)
disconClass Class value of the Disconnect message
disconCause Varchar Cause value of the Disconnect message
disconLocation Location value of the Disconnect message
code Varchar(255) See Chapter ‘CallAnalysis Code’
noL3Duration Indicates for how many seconds there were no layer3
messages received from the mobile station (in 10 sec
steps)
codeDescription Varchar See Chapter ‘CallAnalysis Code’
NoService Smallint Indicates the number of occurrences of situations
where the mobile reported to be in SCAN mode,
means out of service
Initializing smallint
LastAssTimeStamp datetime Timestamp of the last ASSIGNMENT message
(ASS_CMD, ASS_CMPL, ASS_FAIL)
LastAssMsg Varchar Type of the last ASSIGNMENT message (ASS_CMD,
ASS_CMPL, ASS_FAIL)
LastAssCause Varchar Cause value of the last ASSIGNMENT message
CRRandomCode Char(2) Random code of the IMM_ASS message that
corresponds to the Random code of the Channel
Request message
RRCConnReqTimeStamp datetime Number of Connection Request by UMTS
RRCConnSetupTimeStamp datetime Number of Connection Setup by UMTS
numMMTrial int Number of completed Connection Setup by UMTS
numMMSuccess int Number of Radio Bearer Setup
avgBLER Real Average BLER of the last 4 messages before the end
the call
avgTotEcIo real Average aggregated Ec/Io of the last 8 messages
before the end the call
avgUETxPwr real Average UE TxPower of the last 8 messages before
the end the call
avgUERxPwr real Average UE RxPower of the last 8 messages before
the end the call
numOfWCDMARadioValues int Number of WCDMAAGC values used
LastWCDMARadioTimeStamp datetime Timestamp of the last WCDMAAGC message used
numBetterMonitored int Unused
numBetterDetected int Unused
numBetterScannedUMTS int Unused
numRRCConnReq int Unused
The code and the code description are calculated by running the stored procedure
‘sqCallAnalysisCode’. The code field is expressed as a string like ‘C3.01’