Cooling Electric Motor
Cooling Electric Motor
IC 410
Hlađenje preko površine Oberflächenkühlung durch
Cooling over surface through
prirodnom konvekcijom i freie Konvektion und Radiation.
natural convection and radiataion.
radijaciom. Zatvoren motor je bez Geschlossener Motor ohne
Closed motor without external fan.
vanjskog ventilatora. Aussenlüfter.
IC411
Hlađenje preko ravnih i orebrenih Kühlung über gerade und
Cooling over flat and ribbed
površina kućišta motora gerippte Gehäuseoberflächen
surfaces with fan mounted on
ventilatorom, montiranim na mit einem auf der Motorwelle
motor shaft.
osovinu. montierten Lüfterrad.
IC 416
Hlađenje stranom ventilacijom sa Forced ventilated motor, with Kühlung durch Fremdbelüftung
svojim pogonom. independently driven fan. mit Eigenantrieb.
Motori su potpuno zatvoreni, a hlađenje se Motors are completly closed, and cooling is Die Motoren sind völlig geschlossen und
ostvaruje odvodom topline preko orebrenog generated through heat transfer over the ribbed Kühlung erfolgt durch die Wärmeabführung
kućišta pomoću ventilatora montiranog s housing with fan mounted on motor shaft outside über das gerippte Gehäuse mittels eines
vanjske strane motora na vratilo i zaštićenog of the motor side and protected with a fan cap (IC außerhalb des Motors auf der Welle
ventilatorskom kapom (IC 411 prema IEC 60034- 411 in acc. with IEC 60034-6). Fan is designed in montierten und mit der Lüfterhaube
6). Ventilator je takvog oblika da se motor može such manner that it enables motor to be loaded geschützten Lüfterrades (IC 411 nach IEC
nazivno opteretiti bez obzira na smjer vrtnje. with rated parameters regardless of direction of 60034-6). Die Form des Lüfters ermöglicht die
Motore treba montirati uvijek tako da rashladni rotation. Nennbelastung des Motors unabhängig von
zrak može oko njih nesmetano strujati. Ulazni Motors must be mounted to enable cooling air to der Drehrichtung.
otvori zraka na ventilatorskoj kapi moraju biti stream around without any obstacle. Incoming air Die Motoren sollen immer so aufgestellt
slobodni, a razmak od ventilatorske kape do openings on fan cap must be opened and distance werden, dass die Kühlluft um diese frei
prepreke, koja može spriječiti ulaz zraka, smije between fan cap and obstacle which can block air strömen kann. Die Lufteintrittsöffnungen
biti najmanje polovina osne visine motora entering must be at least half of motor frame size auf der Lüfterhaube müssen frei sein und
izražena u mm. rendered in mm. der Abstand der Lüfterhaube von dem
Motori se ne smiju postaviti pokraj toplih Motors must not be positioned near warm objects, Hindernis, welcher den Lufteintritt verhindern
29
Motor Cooling
Totally Enclosed Fan Cooled electric motors (TEFC) are air Noise generation and energy consumption
cooled motors provided with an external fan that is fitted on the The sound pressure level as well as energy consumption can be
electric motor’s own shaft. Totally Enclosed Force Ventilated reduced by using uni-directional axial fans instead of radial fans.
motors (TEFV) are equipped with an independently driven fan. The reduction depends on the power and speed. The reduction
In some cases motors are installed in an air flow and are effect at 6- and 8-pole electric motors (1,000 rpm and 750 rpm)
without a fan. These are Totally Enclosed Air Over motors is less significant.
(TEAO). The air necessary for cooling of the motor is usually
provided by the driven equipment. The Totally Enclosed Non Set-up and maintenance
Ventilated electric motors (TENV) have no fan nor they are When installing an electric motor it is important to ensure that
subject of forced cooling. Some TENV motors are used for short the motor will have sufficient supply of cooling air. It is
term duty cycle (i.e. S2-10min duty). necessary to ensure that the air supply is not blocked in any
way and in a dusty environment regular maintenance must be
Electric motors with forced cooling (TEFC and TEAO) require performed and motor cooling ribs cleaned in regular intervals!
approximately 25 to 30 cubic metres of cooling air per minute
for 100 kW. Definition of terms
— Direction of rotation CW = Clockwise
The following are the important features for effective electric (to the right when viewed from the drive end)
motor cooling (this list is not exhaustive): — Direction of rotation CCW = Counter Clockwise
(to the left when viewed from the drive end)
—Blade shape —TEFC = Totally Enclosed Fan Cooled / IC 411
32 —The drive mode —TEAO = Totally Enclosed Air Over / IC 418
—Noise generation —TENV = Totally Enclosed Non Ventilated / IC 410
—Energy consumption —TEFV = Totally Enclosed Force Ventilated / IC 416
—Electric motor installation and maintenance.
Blade shape
IC410
The simplest option is having the fan mounted directly on to the
electric motor shaft. The rotating speed of the electric motor
determines the speed of the fan. The required direction of
rotation is usually not specified so the standard industrial
electric motors are equipped with bi-directional fan with straight
blades (radial fan) suitable for both directions of rotation (CW or
CCW).