IMPORTANT CAUTION
AWARNING
USE ONLY CRYSTAL CLEAR KEROSENE. NEVER
USE GASOLINE, WHITE GAS, CAMP FUEL OR KEROSENE ONLY
OTHER FLAMMABLE LIQUIDS. USE OF SUCH
FUELS CAN RESULT IN AN EXPLOSIVE FIRE AND
CAUSE SEVERE INJURY.
GAS
i\CAUTION
1. Make sure that there is no fuel leakage from fuel tank and fuel pipe joint.
2. Make sure that flue pipe (exhaust pipe, air supply hose) is connected
properly.
3. Keep heater clean and do not store any flammable items on or near the
heater.
5. Should anything abnormal occur in the heater, remain calm, turn it off (do
not unplug) and contact your Monitor dealer.
6. Risk of burns.
Flue pipe and louver may have high surface
temperature.
7. Do not place yourself or others too close to the heater.
10. In areas of heavy snow accumulation, flue pipe may need to be installed higher to avoid being buried.
In open areas with strong wind, a wind break may be necessary to avoid exhaust gases being blown
back into the intake and causing poor combustion.
L^_ 24"min
Long
Extension^
7^
"n \
Mu st be higher.
kit ,^7 :.•••.;•:?:';.::'::
X X
-Flue
or
Chimney
Point A
Operating Temperature Limits Inside Area Temperature — 4°F
Outside Temperature — 22°F
Point B
Inside Area Temperature 60°F
Outside Temperature — 40°F
-10 0 20 40 60
Inside Area Temperature (T)
SECTION B
SPECIFICATIONS
Model Monitor 422
Fuel Type Crystal Clear Kerosene
Heater Efficiency 93%
Heat Rating High: 22,000 BTU/hour
H.Medium: 17,400 BTU/hour
LMedium: 11,700 BTU/hour
Low: 9,600 BTU/hour
Heater Output High: 20,400 BTU/hour
H.Medium 16,200 BTU/hour
L.Medium: 10,900 BTU/hour
Low: 8,900 BTU/hour
Fuel Tank 1.32 Gal Ions; Separate tank optional
Fuel Consumption High: 0.164 Gallon/hour
H.Medium: 0.13 Gallon/hour
L. Medium: 0.09 Gallon/hour
Low: 0.07 Gallon/hour
Power Source 120 Volts AC; 60 Hz
Power Consumption Ignition: 250 Watts
Operation: 55 Watts (Average)
Heated Air Delivery High: 176 Cubic feet/minute
H.Medium: 176 Cubic feet/minute
L.Medium: 113 Cubic feet/minute
Low: 113 Cubic feet/minute
Vent Pipe Hole 2K-inches Diameter
Dimensions Height: 25.6 inches
Width: 20.9 inches
Depth: 12.4 inches
Weight 55 Pounds, empty
* When considering heat of condensation is lost. then net efficiency is 87%.
SPECIAL FEATURES SAFETY FEATURES
AUTOMATIC IGNITION SAFE RE-LIGHTING:Heater will not restart until its
MEMORY BACK UP: Set memory can be kept in case combustion chamber has cooled.
of power failure for up to 5 minutes. ELECTRICAL PROTECTION: Heater automatically shuts
DUAL BLOWERS: Separate fans for combustion and off in the unlikely event of a malfunction in the
room air circulation. electrical circuitry or disruption of the power supply.
THERMOSTATICALLY CONTROLLED: Adjusts to the NO EXHAUST IN ROOM: Products of combustion are
desired room temperature. discharged outdoors.
BUILT-IN TIMER: Heater will automatically operate as FLUE PIPE:Outside air is drawn through a pipe-within-
programmed by the user. a-pipe venting system. This process preheats
AUTOMATIC RESET AFTER POWER FAILURE: Heater combustion air and regains heat from exhaust
will automatically resume operation after power gases.
is restored.
INDICATOR LIGHTS: Easy-to-see signals show when A CAUTION-ALTERNATE POWER SOURCES
heater is in operation, when timer is activated, and The Monitor 422 may not operate when powered
when the burner is operating in low, medium or by sources such as an auxiliary generator, UPS
high modes. (Uninterrupted Power Source), inverters, etc. Check
CHOICE OF FUEL SUPPLY:Built-in capsule tank or with your dealer for guidance on specific
connect to separate tank. applications.
MULTIPLE HEAT EXCHANGER:Extracts 87% of heat
from burner.
CLEAN OPERATION: Products of combustion are vented
outside.
CONSUMES NO ROOM AIR :Airforcombustion is drawn
from outside.
EASY INSTALLATION: Includes all parts required for
standard installation.
SECTION C
Before installing your heater, be sure to check and comply with local and state building and electrical codes
that may apply to vented heaters in your area. Permanent wiring must be installed by a licensed electrician.
Fig. 1
ACCESSORIES YOU MAY NEED
Check the list below and see your MPI dealer for accessories you may need or want for installation of your heating
system.
ACCESSORY APPLICATION
Medium Flue Pipe P/N 8206 For use where wall thickness is up to inches
Long Flue Pipe P/N 8005 For use where wall thickness is up to 20 inches
Electric Suction Pump P/N 1101 For use with large capacity tank where gravity feed is not
practical
Window Installation Kit P/N 8208, 8209, 8001 For use where "through-the window" flue pipe installation
(See Window Installation below) is desired
Extra Short, Short, Medium or For use where "standard" installation is not practical
Long Extension Kit or Elbow Adapter Kit
(See Flue Pipe Extensions, page 8)
Fitting and Tank For large capacity fueling: To be dealer installed
WINDOW INSTALLATION
The use of "through-the-window" installation for your
flue pipe will require a window installation kit and one
of the 4 (extra short, short, medium or long) extension
kits.
In order to determine which extension kit is required,
measure the distance from the floor to the TOP of
your window sill (see Figure 2) and refer to the chart
below.
7* ^
Fig. 2
IF THE MEASUREMENT IS: YOU NEED:
20% to 25 inches Extra Short Extension Kit P/N 8212
25 to 33% inches Short Extension Kit P/N 8004
33K to 511A inches Medium Extension Kit P/N 8003
51M to86M inches Long Extension Kit P/N 8002
Elbow Adapter Kit P/N 8213
NOTE: Window kit installation is prohibited when the window is required to meet the local building code requirements
for ventilation, emergency escape, or rescue.
One or more Elbow Adapter Kit may be needed if heater is installed on inside wall.
FLUE PIPE EXTENSIONS
Four standard extension kits are available from your 2. These elbows should include the one used at the
Monitor dealer. Most installations can de made with heater but not the one on the air supply hose nor the
one of these kits. In special cases, custom installations integral bends in the flue pipe. (See Figure 3)
may be required. These may be made with components 3. The correct damper as shown on Page 13 must be
purchased from your dealer. used.
8
SECTION D
HEATER INSTALLATION
Step 1: Fill Out Owner Registration Card Step 3: Choose a Location for Your Heater
Remove your owner registration card from the plastic In choosing a location for your heater, the following
envelope containing the owner's guide. It should be guidelines must be considered:
filled out and mailed as soon as possible. • The heater MAY be installed on combustible floors.
• The area around the heater should be free of
Step 2: Check for Parts obstacles that might interfere with the free flow of
Before discarding packing materials, be sure you have air. Allow the clearances shown in Figure 5.
located the following:
Flue Pipe
Sleeve Nut
Spill Tray
Room Temp. Sensor (attached to the rear of the
heater)
Cardboard Template
"STANDARD" Damper
Wall Clamps (2)
Rubber Packing
Joint Pipe
Cloth Insulation Cover
Outer Flange
Pipe Holder
Small Bag of Screws
Tapping, Type A —
Tapping, Type A —
Small Plastic Syringe
39"
Fig. 5
Combustible
18" (45cm)
or more
IMPORTANT:
(1) In areas of heavy snow falls, ground surface clearance (2) In open area with strong wind, a wind break may be
must be increased according to average snow falls, to necessary.
prevent flue pipe from being buried. ._ 24"min
1
Long 1
Extension Must be higher.
kit
Snow
Fig. 6
10
Step 4: Drill a Pilot Hole Use the template to position the hole to be drilled.
NOTE: The following directions apply to "standard" The "red dot" indicates the exact center of the hole.
installation. For other methods, follow instructions Using an electric drill and a long drill bit, make a
included with accessory kits. pilot hole through the wall (Figure 7). Be sure the hole
For walls up to 8% inches thick, use a short extends through the outside wall.
flue pipe; for walls up to 14% inches thick, use
a medium flue pipe; and for walls up to 20 inches
thick, use a long flue pipe.
Fig. 7
CAUTION: The opening on the inside wall should be approximately % inch higher than on the outside wall so
the flue pipe will slope downward when installed. This will allow condensation to drain outdoors.
Step 5: Cut the Hole for the Flue Pipe NOTE .-After cutting the inside wall, remove the insulation.
Using a hole saw attachment and an electric drill, cut Make sure there are no obstructions inside the
a 2]4 inch diameter hole through the inner and outer wall, such as electrical wiring, water pipes, hot
walls (Figure 8). air ducts, etc.
Wall
Fig. 8
11
Step 6: Install the Flue Pipe with the 3 #8x%tapping screws(Figure 9). (See Figure
From INSIDE the building, insert the flue pipe (with 4 for screw size and application.)
arrow pointing "up") into the hole. Fasten the flue pipe
NOTE: Top center port is an extra exhaust port.
tapping screw
Fig. 9
Rubber Packing
Flue Pipe Nut.
Outer Flange
Fig. 11
12
Step 8: Install the Spill Tray Step 11: Connect the Heater to the Flue Pipe
Place the spill tray on the floor where you plan to Move the heater toward the wall, guiding the joint pipe
locate your heater. into the center port of the flue pipe (Figure 14).
Remove the 2 sets of screws from the cabinet (Figure Be sure the joint pipe is completely inserted into the
12). flue pipe.
Position the heater on the spill tray so the legs of the
cabinet fit into the circular indentations in the spil!
tray (Figure 12).
Screws
Fabric Cover
Fig. 15
Joint Pipe
/VOTE'Do not place intake hose onto metal capped
exhaust port.
Fig. 13
13
NOTE: Step 15: Recheck the Heater
The "STANDARD" damper is to be used with Before proceeding, check again to be sure there are
extension kits up to a total overall length of 20 no flammable materials close to the heater. Check to
inches and a maximum of 3 bends (90° elbow). be sure the heater is level.
Examine the flue pipe to be sure connections are tight.
Air damper is not used when extension kit or kits
exceed 20 inches.
Step 13: Install the Flue Pipe Holder
Place the ring of the flue pipe holder around the flue
pipe. The other side of the holder hooks in a slot
directly above the joint pipe at the rear of the heater
(See Figure 16).
Fig. 16
14
SECTION E
FUELING
A WARNING: USE ONLY CRYSTAL CLEAR KEROSENE. NEVER USE GASOLINE, WHITE GAS, CAMP FUEL OR
OTHER FLAMMABLE LIQUIDS. USE OF SUCH FUELS CAN RESULT IN AN EXPLOSIVE FIRE AND
CAUSE SEVERE INJURY.
Step 1: Lift Out the Capsule Fuel Tank "FULL" Fuel Level
To fill with fuel, open the tank cover and lift out the
capsule fuel tank (see Figure 17). Turn the tank upside
down, and remove the fuel cap. If the fuel cap is
difficult to unscrew, press the valve in the center, and
remove.
Fig. 18
Fig. 19
15
REFUELING EXTERNAL TANK INSTALLATION-Gravity Fed
NOTE: When the red light marked "Empty" illuminates When using external tank, changes in heater installation
and flashes, a buzzer will sound for twenty and pipe connections are required.
seconds. The burner mode is changed to "Low"
automatically, and then, the heater will shut off PREPARATION AT HEATER
after 30 minutes. Stepl:
The remaining burning time is indicated at the Remove the capsule fuel tank, and the fuel filter from
display window. the fuel sump tank (see Figure 20).
30 min
20 sec
Step 2:
If kerosene has accumulated in the spill tray or in the
chamber which holds the capsule fuel tank, clean
with a towel or rag. Remove any flammable items
situated near the heater or flue pipe.
Step 3:
Follow directions under "Fueling".
16
Step 2:
Remove fuel with the siphon, remaining fuel must be sucked up with the plastic syringe (see Figure 21).
Plastic Syringe
Fig. 21
Step 3: Step 4:
Wipe off the fuel sump tank with a towel or rag (see Remove the nut at the rear lower side of the heater.
Figure 22). Collect fuel draining from the heater into a container.
Hold the nipple with a wrench and loosen the nut with
the other wrench (see Figure 23).
Nipple
Wrench
Fig. 22
Nut Container
Fig. 23
17
Step 5:
Insert the rubber plug into the disconnected pipe (see
Figure 24).
Wipe off spilled fuel. Rubber Plug Bend the pipe aside
Fig. 24
Step 6:
Remove the screws at the louver, and carefully remove
the louver and front panel (see Figure 25).
Louver
Front Panel
Fig. 25
Step 7: Connect the plugs of red and brown wires marking "U" coming out from the printed wiring board for
turning off the function of the fuel empty float switch (see Figure 26).
Lead Wires
Color: Red/Brown
Marking : "U"
Fig. 26
18
Step 8: Replace the front panel and the louver.
NOTE: External tank installations must comply with the 100 feet and should be free of sharp bends or
National Fire Protection Association code NFPA obstructions.
31 or locally applicable codes, such as the 1979 • Piping should include no inverse U-type bends (to
Uniform Mechanical Code No.5-1. that are avoid air locks, which could block the fuel supply).
consistent with NFPA 31. Check with your local • Only %inch OD copper tubing should be used.
building official. The tubing should be bent carefully to avoid crimping.
• A fuel filter is recommended for use on the fuel line
To install a large capacity, gravity fed external tank, near the tank, and a shut-off valve should be installed
follow the instructions below, and refer to Figure 27 at the tank.
for one possible installation. Use of a qualified installer • Flare connections should be used at the fusible link
is recommended. valve connection on the heater and at the fuel filter
• Installation height of the bottom of the fuel tank to be installed at the tank.
should be 16 inches or more above the floor surface • The fuel tank should be located no closer than 3
on which the heater stands. This ensures that inlet feet to a source of heat.
fuel pressure will be sufficient. • The fuel tank should have an opening for filling on
• The top of the fuel tank should be no higher than the top and a vent with a weather-proof cap on the
Q1A feet above the floor under the heater. Heights side. On some tanks the vent and fill spout use the
above Q1A feet will exceed the 2.5 psi inlet limit, and same opening.
a pressure reducer will need to be installed at or near
the unit. When using a gravity fed tank to supply fuel, the inlet
• The horizontal length of piping should not exceed pressure to the heater must not exceed 2.5 psi.
maximum
(2.6m)
(0.4m)
r %" Flare Connection
1
)
i f I r— i r -3 1
Fusible Link
%" OD Copper Tubing
Valve Connection
NOTE: Fuel tank must be a minimum 3 feet away from flue pipe.
Fig. 27
19
SECTION F
STARTING INSTRUCTIONS
Step 1: Plug in the Heater Step 3: Set "ON" Button
Plug in the AC cord, and route it away from the area Depress the operation button to put it in the "ON"
of the flue pipe. It is recommended that no other position. The "Operation Lamp" lights indicating "Set
appliance share the same outlet. Room Temperature" and "present room temperature".
Burner status lamps will light and ignition will start
Step 2: Prime the Heater after approximately three minutes. In 5 to 10 minutes
If using the heater for the first time, or if the heater the circulation fan will start to operate, and warm air
has not been in operation for sometime, press the fuel will be felt coming through the cabinet grill.
set lever at the lower right hand side of the cabinet
and release it slowly 2 or 3 times (Figure 28).
Fig. 28
EC MY SET ROOM
RUN AUTO °N° C
PLUS
EMPTY BURNER STATUS
TEMP
AM
PM
1 1 1 1 -
58
Fig. 29
20
SECTION G
ADJUSTING ROOM TEMPERATURE
Pressing either the "Up" or "Down" button will increase will automatically change its heat output until the
or decrease the set temperature by 2 degree increments. desired room temperature is reached. While it cycles,
Once desired temperature is displayed, press set you may hear the circulation fan change speed.
button to lock into memory. Depending on the output required to maintain the
The lights on the control panel will indicate the level desired room temperature, the indicator lights will
of heater operation — low, medium or high. The heater illuminate in the following pattern:
The heater will shut itself off temporarily when the desired room temperature has been reached and restart automatically when
necessary to maintain room temperature.
NOTE: The heater may display room temperature 4 degrees above set temperature, depending on heater load
conditions, before shutting itself off.
SECTION H SECTION I
TURNING OFF THE HEATER RELIGHTING THE HEATER
To turn off the heater, press the Operation Button to Automatic controls prevent your heater from relighting
put it in the "Off" position (Figure 29).The operation light after the Operation Button has been set to "Off" until
will go out, and the fuel flow will stop. heater has cooled.
After turning heater off the fans will continue to run If the Operation Button is put in the "On" position
until unit has cooled down to the point where the during the cooling period, the heater will automatically
fans will automatically stop. relight at the end of the period.
21
SECTION J
PROGRAMMING THE HEATER
SETTING THE CLOCK
Step 1: Set the Timer Selector
Press the "Timer Selector" button, at which time the "Clock Set" light will illuminate. The LED indicator in the
Display Window will show 88:88 at this point.
DISPLAY WINDOW
RUN AUTO EC
°N°MY EMPTY BURNER STATUS SET f ROOM
r LUO — TEMP p^T—IT
AM - O
PM
Q
TEMPj ]
en en a en
UP DOWN
TIMER SELECTOR
Fig. 30
Step 2: Set the Hour NOTE: The "Hour" and "Minute" Buttons can be pressed
Press the "Hour" Burton until the correct hour (either and held or pressed momentarily to change the
A.M. or PM.) appears in the window. time.
22
PROGRAMMING FOR AUTOMATIC HEATER OPERATION
The Monitor 422 Heating System is capable of providing Step 3: Activate Automatic Operation
up to 4 different temperature settings for 4 different For the heater to operate on automatic once the
times of the day. Not all 4 settings have to be used;2, settings are in memory, simply press the "Auto" Button
3 or 4 settings can be used. A clear understanding on the control panel. The "Auto" Light will illuminate to
of programming temperatures and time from the previous confirm the heater is in the automatic operation mode.
pages is needed before programming the automatic The heater will now maintain the programmed temp
settings. Also, the present time must have been set. for that time of day.
Step 1: Setting the 1st Time/Temperature IMPORTANT:The heater will not operate in automatic
Pressing the Timer Selector Button will illuminate the unless the On/Off switch is in the "On"
Time/Temp Light. position.
Press the "Time" Button. Set the 1st desired time by
pressing the "Hour" and "Minute" Buttons as described Step 4: Clearing An Automatic Setting
under, "Setting the Clock". Once the desired time "AM If you wish to clear any automatic setting, press the
or PM" is displayed, press the "Set" Button to lock Timer Selector Button to the appropriate setting and
into memory. press the "Clear" Button. A new setting will need to be
Press the "Temp" Button. Set the desired temperature entered otherwise the old setting will return after 30
for the 1st time setting by using the "Up" and "Down" seconds.
Buttons. Once the desired temp is displayed, press the
"Set" Button to lock into memory.
Example: 1st Time/Temp
SAM 60°
MANUAL OPERATION
Step 2: Setting the 2nd Time/Temperature To deactivate the automatic operation, simply press
Press the Timer Selector Button again and the 2nd the "Auto" Button. The "Auto" Light will no longer be
Time/Temp Light will illuminate. illuminated and the heater will run on a manual setting.
Follow same steps as above, except for 2nd time/temp. This setting will be determined by the previous auto
(ie;2nd 5PM 74Degrees) setting for that time of day, unless reset. The automatic
Repeat if a 3rd or 4th setting is desired. settings will remain in memory even if the unit is
running in manual, unless there is a power outage for
Typical Example of a 4-time/temp selection:
TIME TEMP more than 5 minutes.
1st SAM 60°
2nd 5PM 74°
3rd 11PM 70°
4th 5:30AM 76°
23
SECTION K
PROTECTIVE FEATURES OVERHEAT PREVENTION
LOSS OF POWER-AUTOMATIC RESET: If your heater overheats, a thermostatic switch will
NOTE:If power to the heater is interrupted, a thud-like automatically stop the flow of kerosene and extinguish
noise may be heard in the combustion chamber. the flame. The Burner status indicators are blinking.
This is nomal, and should not cause alarm. Restore heater operation by following the steps
For power interruptions of up to 5 minutes, the below.
NOTE: Other symptoms listed in the trouble shooting
set memory is kept and will resume operation
chart may cause burner status indicators to
automatically with the set memory.
blink, besides an overheat situation.
For power interruptions beyond 5 minutes, your
heater will resume operation (after a 3 minutes
cool down period) in the MANUAL mode and Step 1: Turn the Heater Off
maintain room temperature according to the Press the Operation Button to put it in the "Off" position.
setting temperature you've selected by using the
slide selector for the reset temperature at the Step 2: Allow the Heater to Cool
lower right hand side of the cabinet (Figure 31). Wait approximately 30 to 45 minutes for the heater to
When the TIME Button is pressed or the TIMER cool completely.
SELECTOR Button is pressed to illuminate the
CLOCK SET Light, The Display Window will Step 3: Unplug the Heater from the Wall Outlet.
show 88:88 indicating the need to reset the
clock and re-program the heater for automatic Step 4: Remove Obstructions
operation. The overheated condition may be caused by obstructions
blocking the air flow to the heater. Check:
• The front of the heater
REMARK:In order to display reset temperature, • The circulation fan (on the back of the heater).
it should be set before the heater is plugged • The flue pipe (outside)
in and energized.
New reset temperature selected after plugged Step 5: Remove the Louver
in will take effect only after a power loss, greater Remove the screws at the louver, and carefully remove
than five minutes. the louver (Figure 32).
RESET TEMPERATURE
50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80
Louver
Fig. 31
ELECTRICAL FUSE
In the unlikely event of a failure in the heater's
electrical system, a fuse will "blow" and interrupt the
power. Do not attempt to change the fuse. Fig. 32
Contact your MPI dealer for the name of a trained
and certified service representative in your area. Remove any accumulation of dust or other matter that
may be covering the burn chamber and the heat
exchangers inside the heater.
NOTE: Using a surge protector can minimize the chances Step 6: Replace the Louver
of a blown fuse caused by power surges.
Step 7: Plug in the Heater
Step 8: Re-program the Heater
Step 9: Turn Heater On
/\ CAUTION: If the unit overheats a second time, turn
it off and contact your MPI dealer for
service.
24
SECTION L
CARE OF THE HEATER
Push operation switch to "OFF" remove the AC Plug from the wall outlet and wait approximately 30 minutes for
the heater to cool before performing any of the following steps.
Step 1: Retrieving Objects from Inside the Heater Step 6: Cleaning the Fuel Strainer
Should an object fall inside the heater, through the The strainer of the fuel constant level valve should be
grill openings, it must be removed to avoid affecting cleaned once a year and before storing heater at the
the operation of the heater. end of each season.
After allowing the heater to cool, remove the front
cover panel. (See Step 5 of the previous section.) Step 6-A: Valve Position-Open/Close
After the object has been removed, replace the front Turn knob of the shut -off valve installed at the fuel inlet
cover before attempting to re-start the heater. connection to close the fuel line. (See Figure 27).
NOTE: The valve 'is located at the back of the heater.
Turn counter clockwise to open, clockwise to
Step 2: Cleaning the Cabinet
close. If threaded valve stem is sticking up
When the cabinet is soiled, wipe it with a damp cloth. about yc, valve is open. If handle screws off
Restore the shine with a dry cloth.
stem, valve is closed.
The use of abrasive household cleaners may dull
the finish. Step 6-B:
To catch the fuel which will drain out, set the drain
guide made by cardboard below the strainer cover,
Step 3: Checking the Flue Pipe with a small container under it. (See Figure 33)
At the beginning of each heating season, check the
inside of the flue pipe. Foreign matter, spider webs, Step 6-C:
etc. must be removed. Loosen the two screws from the strainer cover and
Be sure all fittings and joints are tight. remove.
Step 6-D:
Step 4: Cleaning the Interior Remove the strainer and wash with pure kerosene.
Remove the Front Cover Panel (as described in Step
If strainer is damaged, replace it.
5 of the previous section), and vacuum and wipe away
dust or other accumulation. Step 6-E:
Look for signs of fuel leakage around the joint pipe Return the strainer to its original position. Replace
and the bottom of the cabinet. If fuel is detected, wipe strainer cover and screw to secure.
it away and if necessary, contact your MPI dealer for
any necessary repairs. Step 6-F:
Wipe away any spilled kerosene.
Step 5: Cleaning the Blower Guard Step 6-G:
Heating efficiency will be reduced if the blower guard Turn the knob of the shut-off valve to open. Check for
at rear of the cabinet is blocked with dirt or dust. kerosene leakage.
Blockage also produces a rise in heat that could cause
the heater to shut off.
NOTE: Your Monitor may sometimes require more
Wipe the guard clean at least once a week.
service than that shown above. Should this occur
please contact your Monitor Products, Inc., dealer
for service. A preseason maintenance check up
could be performed by your dealer to ensure
trouble free operation during the season. Ask
him for details of his routine maintenance
program.
25
Strainer
Cover
Fig. 33
26
SECTION M
TROUBLESHOOTING GUIDE
Should symptoms appear during the operation of your heater, refer to the chart below, If you are unable to restore
normal operation, contact your MPI dealer for service.
SYMPTOM CAUSE REMEDY
Heater does not go on Timer is in Auto. Press Auto Button again.
with operation switch. Check plug and power source.
AC cord is disconnected
from wall outlet. Power Reset circuit breaker.
failure.
Out of fuel. Press the fuel set lever at the lower
right hand side of the cabinet. Check
"Empty" light. If illuminated, refuel heater.
If separate tank is used "Empty" light
does not operate.
Igniter Failure. Call your MPI Dealer for Inspection
and/or Replacement.
Water in fuel. Refill with fresh kerosene. Section L.
Note: If strainer is severely clogged,
contact your Monitor dealer to check
and clean the inside of constant level
valve and pump screen.
Clogged fuel strainer. Clean fuel strainer.
See "Care of the heater"
Section L.
Heater extinguishes after Air pocket in fuel line. Press fuel set lever on lower right hand
lighting. side of the cabinet and release slowly
2 or 3 times.
Out of fuel. See "Empty Fuel Tank" Section E.
Erratic changes in room Poor location of heat sensor. Relocate the sensor.
temperature. (Slight Poor air movement. Make sure clearances are kept around
differences in room unit.
temperature are normal.) Add room fans to better circulate air
throughout area.
Automatic timer does not Operation switch is not Depress operation button to "ON"
start heater. in the "ON" position. position.
Timer is in Manual. Press Auto Button.
Timer improperly See "Programming for Automatic
programmed. Opearation" Section J.
Power interruption. See "Loss of Power", Section K.
Poor flame, sounds of Loose flue pipe. Allow heater to cool completely;
combustion, soot at the tighten all connections.
rear of the heater.
Soot on inside of burner Obstruction of combustion Inspect air intake system and air
window or exhaust ports air intake system or supply elbow for blockage. Clean with
of flue pipe. combustion fan failure. a brush,if necessary, and carefully
reconnect.
Heater switches from Power interruption; automatic reset. See "Loss of Power",
automatic to manual operation: Section K.
display window shows 88 : 88.
NOTE:Several of the symptoms mentioned above may also be signs that your unit is due for routine maintenance,
especially if it is several years old. Contact your Monitor dealer for an appointment.
27
Monitor 422™ Vented Heating Systems Limited Warranty
MONITOR PRODUCTS, INC., warrants each 7. SOLE REMEDY: The remedy and liability for any
MONITOR 422 vented heating system sold by it to breach of warranty, express or implied, set forth
be free from defects in material and workmanship, above is the sole and exclusive remedy and the
under normal use and service, for one year after limit of liability for any such breach.
the date of original retail purchase, subject to the
term and conditions stated below. An extended 8. EXCLUSIONS AND IMPLIED WARRANTIES: THIS
parts only warranty period of 36 months is provided WARRANTY DOES NOT EXTEND TO ANY
for combustion chamber and heat exchanger. The DEFECT DUE TO THE NEGLIGENCE OF
remainder of the unit is subject to the 12 months OTHERS, FAILURE TO INSTALL, OPERATE OR
warranty as provided herein. MAINTAIN THE HEATER IN ACCORDANCE
WITH THE INSTALLATION, OPERATION AND
1. WARRANTOR: This warranty is granted by MAINTENANCE INSTRUCTIONS FURNISHED
MONITOR PRODUCTS, INC., P.O. Box 3408, WITH EACH NEW HEATER, UNREASONABLE
Princeton, New Jersey 08543. USE, ACCIDENTS, ACTS OF GOD, FIRE, SNOW,
FLOODS,LIGHTNING,ALTERATIONS,ORDINARY
2. PARTIES TO WHOM WARRANTY IS EXTENDED:
WEAR AND TEAR, THE USE OF UNAUTHORIZED
This warranty shall be extended only to the
OR NON-STANDARDIZED PARTS OR
original retail purchaser.
ACCESSORIES OR THE USE OF ANY FUEL
3. PARTS COVERED: All products and parts OTHER THAN GOOD QUALITY KEROSENE
manufactured by or for MONITOR PRODUCTS, SUCH AS 1K GRADE. ALL IMPLIED
INC., except as provided for herein. Replacement WARRANTIES, IF ANY, ARISING UNDER
parts are warranted only for the balance of the STATE LAW IN CONNECTION WITH THE SALES
original warranty period. BY MONITOR PRODUCTS, INC., OF ANY NEW
HEATER ARE LIMITED IN DURATION TO THE
4. PARTS NOT COVERED: The following parts are DURATION OF THIS WRITTEN WARRANTY.
not covered by this warranty: fuel filters, venting THERE ARE NO WARRANTIES, EXPRESS OR
kits, extension kits, fuses, and all parts damaged IMPLIED, OF MERCHANTABILITY, FITNESS
by lightning. FOR A PARTICULAR PURPOSE OR OTHERWISE
WHICH EXTEND BEYOND THIS WARRANTY
5. REMEDY: If, within the applicable warranty MONITOR PRODUCTS, INC., SHALL NOT BE
period, any product or part included in this RESPONSIBLE FOR ANY INCIDENTAL OR
warranty proves to be defective in material and/or CONSEQUENTIAL DAMAGES. WHETHER AS A
workmanship, then MONITOR PRODUCTS, INC., RESULT OF BREACH OF WARRANTY,
shall repair or replace, at its option, the defective NEGLIGENCE, STRICT LIABILITY IN TORT OR
product or part. Service at the point of installation OTHERWISE.
(not including dealer travel time) will be provided NOTE:SOME STATES DO NOT ALLOW:(A)
at no charge to the customer, but must be LIMITATIONS ON HOW LONG AN IMPLIED
performed by a MONITOR PRODUCTS, INC., WARRANTY LASTS;OR (B) THE EXCLUSION
dealer authorized to sell and service the OR LIMITATION OF INCIDENTAL OR
MONITOR 422 vented heating system. CONSEQUENTIAL DAMAGES, SO THE
6. PROCEDURE FOR OBTAINING PERFORMANCE ABOVE LIMITATIONS OR EXCLUSIONS MAY
UNDER THIS WARRANTY: In order to obtain NOT APPLY TO YOU.
performance of the obligations under this
warranty, the original purchaser must promptly 9. NO VARIATION OF TERMS: THE PARTIES IN-
(in no event later than thirty (30) days after TEND THAT THIS WARRANTY BE THE EXCLU-
discovery of the defect) notify the local MONITOR SIVE AND FINAL EXPRESSION OF THEIR
PRODUCTS, INC., dealer authorized to sell and AGREEMENT.
service the MONITOR 422 vented heating system. No person has the authority to orally, in writing
Service will be provided during normal business or in any other way vary the terms, conditions
hours within a reasonable time after the dealer or exclusions, of this warranty or to make any
has been notified of the need for service. If you express warranties other than those contained
are unable to locate a local MONITOR herein.
PRODUCTS, INC., dealer authorized to sell and
service the MONITOR 422 vented heating system, 10. LEGAL RIGHTS: This warranty gives you specific
call or write to: SERVICE DEPARTMENT, legal rights and you may also have other rights
MONITOR PRODUCTS, INC., P.O. BOX 3408, which vary from state to state.
PRINCETION, NEW JERSEY 08543, 908-329-
0900.
Any claim made under this warranty must be
MONITOR PRODUCTS, INC.
accompanied by proof of original purchase date
P.O. BOX 3408
sales invoice or cancelled check showing
PRINCETON, N.J. 08543
serial number is satisfactory evidence.