Sie sind auf Seite 1von 6

Wall Design Request Form

This form is for Wainscoting Horizontal wall application only. Please use Stair Design Request Form for angled stair walls.
Phone: (888) 460-6324, Fax: (256) 767-2916 or visit us at www.NewEnglandClassic.com By providing the requested design information, we will provide you with a detailed wall panel design, bill of materials list and a price for your project.

Date: __________________________________ Project Name: _______________________________ Project Contact: _________________________________ Address: ______________________________________City_________________State______Zip___________ Daytime Phone: ______________________Fax: _____________________E-mail: _______________________ Dealer Name: ________________________________Dealer Contact: _________________________________

STEP 1: Define Project Stage.


Wallboard has been applied or is existing. Room is rough framed. Thickness of wallboard: Thickness of finished floor material: 1/2 3/8 5/8 1/2 3/4 other _________ other _________

STEP 2: Define Product Scope.


1. Please specify the following selections with a check mark in the provided box. Style: ClassicTraditional (Raised panel with beaded rails) ClassicAmerican (Flat panel with beaded rails) ClassicModern (1/8 Revealed flat panel with flat rails) ClassicBeadboard (Beaded design panels with beaded rails) ClassicCottage (2-tier system 12x 12 panel above beadboard panel with beaded rails) ClassicRustic (Hand-carved and scraped panels with matching rails) Specifications: ClassicTraditional, ClassicAmerican and ClassicModern
System Height: Panel Width: 32 9 32 36 12 36 40 15 40 44 18 44 56 23 69 60 31 73 Custom Ht______ Custom_________ 104 108 Custom________

2.

ClassicBeadboard
System Height:

ClassicCottage
System Height: 48 56 Panel Style in Top Tier (Required): Flat Raised

ClassicRustic
System Height: 36 44

3.

Species & Finishes: ClassicTraditional, ClassicAmerican, ClassicBeadboard, ClassicCottage and ClassicModern


Wood Species: __Paintable/Primed __Oak __Maple __Cherry Finishes: _Unfinished _Primed _White Paint _Natural _Golden Honey _Warm Chestnut __Cinnamon _Nutmeg _Merlot _ Tuscan Coffee __ Custom (submit color swatch for matching. $100 upcharge applies)

ClassicRustic
Species: Only Available in Hand-Scraped Maple Finish: _Unfin. _Natural _ Golden Honey _ W.Chestnut _Cinnamon _Nutmeg _Merlot _Tuscan Coffee *Please continue to page 2 of the Wall Design Request Form to complete your design request. RPX-LT21- 12.23.05

Page 1 of 6

Wall Design Request Form (continued)


Project Name: _______________________________________________Date: _______________________ 4. Baseboard(s): New England Classic wall systems are provided with a standard baseboard in heights of 4 or 8 depending on system height. If you choose to use a secondary baseboard in conjunction with New England Classic baseboard, please check the box below and supply the dimensions requested. Built-up baseboard (REQUIRED - Enter dimensions below.)
4" OR 8" RAIL 6" - 16" (VARIES)

BASE (BY OTHERS)

Thickness (T): ____________ Height (H): ______________


T

5.

Casing Option(s) (i.e. door & window trim): Please select one (1) option. Please supply appropriate New England Classic CasingPak. (4 system) Owner supplied or already existing casing (REQUIRED - Enter dimensions below.)
T W

Thickness (T): ____________ Width (W): ______________

STEP 3: Sketch Room Plan and Select Appropriate Project Measuring Guideline.
1. Copy the Design Request & Sketch Sheet for each room. 2. Fill in name of room on each sheet. 3. Please determine project conditions and complete your Project Design in accordance to the Project Measuring Guideline (#) indicated below. If Owner is keeping existing casing. Follow Project Measuring Guideline Example #1 If using New England Classic Casing. Follow Project Measuring Guideline Example #2 If Owner is supplying casing which is not currently installed. Follow Project Measuring Guideline Example #2 If project is in rough framing stage. (No wallboard installed) Follow Project Measuring Guideline Example #3

STEP 4: Submit to New England Classic. Fax all pages to Design Services at (256) 767-2916 or Mail to: New England Classic Attention: Design Services 4145
Parkway
Drive Florence,AL35630 For further assistance Call NEC at: (888) 460-6324
*Please continue to the Wall Design Request Data Chart and Sketch Sheet to complete your design request. RPX-LT21- 12.23.05 Page 2 of 6

Wall Design Request Data Chart & Sketch Sheet


Print your Project Name to allow Design Services to track Sketch Sheet information to the proceeding Design Request Form data sheet.

Project Name: ________________________________ General Notes:


ITEM

Date: _______________________________________
CASING-DIMENSIONS WINDOW REQUIRED IF NEW OR SILL/JAMB REPLACING CASING HEIGHT WIDTH REVEAL

DOOR = D WINDOW = W HEATER = H OTHER = O D W H O

UNIT SIZE

WIDTH

HEIGHT

1 2 3 4 5

Room Name: ________________________ Design Sketch Area:

*Please make a copy of Wall Design Request & Sketch Sheet for each room. RPX-LT21- 12.23.05

Page 3 of 6

Wall Design Request Data Chart & Sketch Sheet


Print your Project Name to allow Design Services to track Sketch Sheet information to the proceeding Design Request Form data sheet.

Project Name: ________________________________ General Notes:


ITEM

Date: _______________________________________
CASING-DIMENSIONS WINDOW REQUIRED IF NEW OR SILL/JAMB REPLACING CASING HEIGHT WIDTH REVEAL

DOOR = D WINDOW = W HEATER = H OTHER = O D W H O

UNIT SIZE

WIDTH

HEIGHT

1 2 3 4 5

Room Name: _________________________ Design Sketch Area:

*Please make a copy of Wall Design Request & Sketch Sheet for each room. RPX-LT21- 12.23.05

Page 4 of 6

Project Measuring Guideline Examples


#1 - Project with Existing Casing & Wallboard Installed
Follow these guidelines and record your measurements on the sketch sheets & chart provided. Start with one wall and then repeat for each wall. 1. Measure overall length of walls. 2. Measure from wall corner(s) to outside edge of existing casing on D windows, doors & other items that could interfere with wall 1 2 paneling (Do not include switches & outlets). Repeat process 3 for each wall elevation. 3. Measure width of window & door openings from outside edges of 4 5 casing. 4. Measure sill height from bottom of sill to finished floor. 5. Measure height of window & door openings from outside edge of casing to finished floor. 6. Enter dimension information into project data chart. 7. Sketch project, dimension and label items. 8. See examples below for guidance.
1'-91" Bottom of 4 Window Sill
ITEM D = DOOR W = WINDOW H = HEATER O = OTHER UNIT SIZE WINDOW SILL/FRAME CASING -DIM REQUIRED IF NEW OR REPLACING CASING

WIDTH 3'-6" 3'-6" 5'-3"

HEIGHT 7'-1" 7'-1" 0'-9"

HEIGHT 1'-9 1/4"

WIDTH

REVEAL

Project Data Chart Example


W IN D O W

1
2 '-1 3 /4 " 5'-2 3/4" 3 '-8 1 /2 "

3
HEATER 10'-11"

7'-1"

2'-3"

3'-6"

MEASURE TO EDGE

1'-113/4"

9 '-0 "

Measuring to Existing Casing Example

Project Sketch Dimensioned to Existing Casing

#2 - Project with No Casing or Replacing Existing Casing & Wallboard Installed


D = DOOR 1. Measure overall length of walls. ITEM W = WINDOW H = HEATER 2. Measure from wall corner(s) to uncased frames on windows, O = OTHER doors & other items that could interfere with wall paneling (Do D W H O not include switches & outlets). Repeat process for each wall 1 2 elevation. 3 3. Measure width of window & door openings from uncased frame 4 openings. 5 4. Measure sill height from top of window frame to finished floor. 5. Measure height of window & door openings from uncased frame to finished floor. 6. Enter future casing & reveal width into project data chart. 7. Enter dimension information into project data chart. 8. Sketch project, dimension and label items. 9. See examples below for guidance. UNIT SIZE WINDOW SILL/FRAME CASING -DIM REQUIRED IF NEW OR REPLACING CASING

WIDTH 3'-0" 3'-0" 5'-3"

HEIGHT 6'-6" 6'-6" 0'-9"

HEIGHT 1'-10"

WIDTH 0'-4" 0'-4"

REVEAL 0'-1/4" 0'-1/4"

Project Data Chart Example


WINDOW

1
2'-6" 5'-7" 3'-0" 3'-6" 2'-10"

1'-10" Top of Window Frame

3
HEATER 10'-11"

DOOR

WINDOW WINDOW FRAME

WALL MEASURE TO INSIDE EDGE

6'-6"

2'-4"

9'-0"

Measuring to Unit Inside Frame- No Casing

Project Sketch Dimension to Unit Inside Frame

RPX-LT21- 12.23.05

Page 5 of 6

2'-10"

2'-6"

3'-0"

3'-0"

1'-10" TO TOP OF WINDOW FRAME

5'-3"

2'-10"

WINDOW FRAME CASING

3'-8 1/2"

DOOR

WINDOW

WALL

1 '-9 1 /4 " T O BOTTOM OF W IN D O W S IL L

5'-3"

2'-10"

3 '-1 3 /4 "

Project Measuring Guideline Examples


#3 Project at Rough Framing Stage with no wallboard installed
Follow these guidelines and record your measurements on the sketch sheets & chart provided. Start with one wall and then repeat for each wall.

1. Measure overall length of walls. 2. Measure wall corner(s) to inside edge of rough opening (RO) for windows, doors & other items that could interfere with wall paneling (Do not include switches & outlets). Repeat process for each wall elevation. 3. Measure width of window & door rough openings (RO). 4. Measure sill height from sub floor to inside top edge of sill rough opening. 5. Measure height of rough opening for window & door openings, from sub floor to bottom of header. 6. Enter dimension information into project data chart. 7. Enter future casing width & reveal width to be applied or installed. 8. Sketch project, dimension and label items. 9. See examples below for guidance.
ITEM D = DOOR W = WINDOW H = HEATER O = OTHER UNIT SIZE WINDOW SILL/FRAME CASING -DIM REQUIRED IF NEW OR REPLACING CASING

D 1 2 3 4 5

WIDTH 3'-0" 3'-0" 5'-3"

HEIGHT 6'-6" 6'-6" 0'-9"

HEIGHT 1'-10"

WIDTH 0'-4" 0'-4"

REVEAL 0'-1/4" 0'-1/4"

Project Data Chart Example

W IN D O W O P E N IN G

W ALL F R A M IN G M EASURE T O IN S ID E EDGE

WINDOW 3'-6 1/2" 2'-10 1/2" HEATER 2'-10 1/2" 5'-3"

2'-6 1/2" 5'-7 1/2"

1
3'-0"

1'-10" Top of Window Frame

3
1'-10" TO TOP OF WINDOW FRAME 11'-0"

DOOR

6'-6"

3'-0"

2'-4 1/2"

3'-0"

9'-1"

Measuring Rough framing- Window

Project Sketch Dimension to Unit Inside Frame

RPX-LT21- 07.13.11

Email: design@newenglandclassic.com

Phone: (888) 460-6324

Page 6 of 6

Das könnte Ihnen auch gefallen