Sie sind auf Seite 1von 3

44SM7

ARINC 429 to Synchro Converter

MODEL 44SM7
ARINC 429 to SYNCHRO CONVERTER

Description
The Model 44SM7 is a self contained, remotely mountable module that accepts low speed (12.5 KHz) ARINC 429 (Label
114, Desired Track [True] and Label 121, Horizontal Command) from the Garman 530 or other compatible GPS units.
The unit will convert this data into three wire, 11.8 V Line-to-Line Synchro information.

Specifications
Signal Input: Two-wire ARINC 429 Low Speed (12.5 KHz), Label 114-Desired Track and Label 121 –
Horizontal Command.
Input Impedance: 12 KΩ min.
Power: 100Vrms to 122Vrms (115Vrms nominal) 400Hz ±10% (Transformer Isolated)
Reference: 26Vrms, 400Hz @ 4 ma max (Transformer Isolated)
Power and Reference must be of the same phase.
Resolution: 0.05°
Accuracy: 0.5°
Output format: Synchro S1 (X), S2 (Z), S3 (Y)
Output Voltage: 11.8VL-L ±5%
Output Load: Litton Poly-Scientific CDH-11-B-2 (Zso = 12.9+j76.6 ohms)
Loaded by Harowe 8CT-101-A-5 (Zso = 33.6+j100 ohms)
Output Phase Shift: 0° ±3° with respect to the Reference
Valid Flag 28VDC and Ground Valid, 250ma
Protection: Unit will not be damaged by loss of Power or Reference. The Synchro output is internally limited
and will not be damaged by short circuit conditions. Recovery from short circuit is within 0.5 sec.
Grounds: Power and reference inputs are transformer isolated and are isolated from chassis ground and Z
common. Z common is isolated from the chassis. Z common, Chassis, and Power Low should be
interconnected at a single point.
Finish: Alodine per MIL-C-5541, Class 3
Weight: Approx 6.5 lbs
Size: Approx. 8.0” x 6.75” x 3.24”
Environment: Per RTCA/DO-160D (See Test requirements below)
Burn-In: 96 Hours with power applied. Chamber temperature will be cycled from +70°C to -45°C with a
dwell time of 2 hours at each temperature.

North Atlantic Industries, Inc. . 4-13-04 44SM7A001 Rev C


631.567.1100/631.567.1823 (fax)
170 Wilbur Place, Bohemia, NY 11716 www.naii.com / e-mail:sales@naii.com Cage Code: OVGU1 Page 1 of 3
J1 Pin Designation

A 115V 400Hz Hi
B 115V 400Hz Lo
C Power Ground
D Chassis Ground
E S1(X)
F S2(Z)
G S3(Y)
H +28 VDC Hi
J NOT USED
K Input Selector
Jumper
L +28VDC Return
M Input Selector
Jumper
N 26V 400Hz Ref. Hi
P 26V 400Hz Ref. Lo
R ARINC 429 Input Lo
S Chassis Ground
T NOT USED
U ARINC 429 Input Hi
V +28VDC Valid Flag
W Ground Valid Flag

J1 connector type: MS3122E-16-26P


J1 mating connector: MS3126-16-26S (not supplied)

Note: Connect pins “K” and “M” together for RUN (Desired Track ± Horizontal Command) function.
Leave pins “K” and “M” open for SET (Desired Track) function.

North Atlantic Industries, Inc. . 4-13-04


631.567.1100/631.567.1823 (fax) 44SM7A001 Rev C
170 Wilbur Place, Bohemia, NY 11716 www.naii.com / e-mail:sales@naii.com Cage Code: OVGU1 Page 2 of 3
DO-160D TEST REQUIREMENTS

Conditions Section Description of Tests


Temperature and Altitude 4.0 Test Equipment to Category “B2” per Table 4-1 except as
noted below.
Operating Low Temperature
4.5.1 -45º C
Operating High Temperature
4.5.3 +70º C
Short Time Operating High
temperature 4.5.2 +70º C
Loss of Cooling 4.5.4 Test Not Required, (Cooling air not required)
Ground Survival Low
Temperature 4.5.1 -55º C
Ground Survival High
Temperature 4.5.2 +85º C
+25,000 feet
Altitude 4.6.1 +7,600 meters
Decompression 4.6.2 Test Not Required
Overpressure 4.6.3 Test Not Required
Temperature Variation 5.0 Test Equipment to Category “B”
Humidity 6.0 Test Equipment to Category “A”
Operational Shock and Crash
Safety 7.0 Test Equipment to Category “C”
Operational Shock 7.2 par. 7.2.1
Crash Safety 7.3 Test per Table 7-1, Aircraft Type 1R
Vibration 8.0 Test Equipment without shock mounts to Category U (Table
8-1, Aircraft Type 1, Zones 1&2)
Explosion Proof-ness 9.0 Equipment identified as Category X, no test required
Waterproof-ness 10.0 Equipment identified as Category X, no test required
Fluids Susceptibility 11.0 Equipment identified as Category X, no test required
Sand and Dust 12.0 Equipment identified as Category X, no test required
Fungus 13.0 Equipment identified as Category X, no test required
Salt Spray 14.0 Equipment identified as Category X, no test required
Magnetic Effect 15.0 Test Equipment to Class Z
Power Input 16.0 Test Equipment to Category A(CF)
Voltage Spike 17.0 Test Equipment to Category B
Audio Frequency Susceptibility 18.0 Test Equipment to Category A(CF)
Induced Signal Susceptibility 19.0 Test Equipment to Category A
Radio Frequency Susceptibility 20.0 Test Equipment to Category R,R
Radio Frequency Emissions 21.0 Test Equipment to Category L
Lightning Induced Transient 22.0 Test Equipment to Category A2XXX
Susceptibility
Lightning Direct Effects 23.0 Equipment identified as Category X, no test required
Icing 24.0 Equipment identified as Category X, no test required
Electrostatic discharge 25.0 Test Equipment to category A

North Atlantic Industries, Inc. . 4-13-04


631.567.1100/631.567.1823 (fax) 44SM7A001 Rev C
170 Wilbur Place, Bohemia, NY 11716 www.naii.com / e-mail:sales@naii.com Cage Code: OVGU1 Page 3 of 3