Sie sind auf Seite 1von 22

Nokia Siemens Networks

GSM/EDGE BSS, rel.


RG10(BSS), operating
documentation, issue 06

Activate

Activating and Testing BSS5050,


BSS10118, BSS11116 and BSS8085: Dual
Band Network Operation
DN9812734

Issue 8-0
Activating and Testing BSS5050, BSS10118,
BSS11116 and BSS8085: Dual Band Network Opera-

The information in this document is subject to change without notice and describes only the
product defined in the introduction of this documentation. This documentation is intended for the
use of Nokia Siemens Networks customers only for the purposes of the agreement under which
the document is submitted, and no part of it may be used, reproduced, modified or transmitted
in any form or means without the prior written permission of Nokia Siemens Networks. The
documentation has been prepared to be used by professional and properly trained personnel,
and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes
customer comments as part of the process of continuous development and improvement of the
documentation.
The information or statements given in this documentation concerning the suitability, capacity,
or performance of the mentioned hardware or software products are given "as is" and all liability
arising in connection with such hardware or software products shall be defined conclusively and
finally in a separate agreement between Nokia Siemens Networks and the customer. However,
Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions
contained in the document are adequate and free of material errors and omissions. Nokia
Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which
may not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO
EVENT WILL Nokia Siemens Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTA-
TION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDI-
RECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED
TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY
OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION
IN IT.
This documentation and the product it describes are considered protected by copyrights and
other intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark
of Nokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respective
owners, and they are mentioned for identification purposes only.
Copyright © Nokia Siemens Networks 2010. All rights reserved

f Important Notice on Product Safety


Elevated voltages are inevitably present at specific points in this electrical equipment.
Some of the parts may also have elevated operating temperatures.
Non-observance of these conditions and the safety instructions can result in personal
injury or in property damage.
Therefore, only trained and qualified personnel may install and maintain the system.
The system complies with the standard EN 60950 / IEC 60950. All equipment connected
has to comply with the applicable safety standards.

The same text in German:


Wichtiger Hinweis zur Produktsicherheit
In elektrischen Anlagen stehen zwangsläufig bestimmte Teile der Geräte unter Span-
nung. Einige Teile können auch eine hohe Betriebstemperatur aufweisen.
Eine Nichtbeachtung dieser Situation und der Warnungshinweise kann zu Körperverlet-
zungen und Sachschäden führen.
Deshalb wird vorausgesetzt, dass nur geschultes und qualifiziertes Personal die
Anlagen installiert und wartet.
Das System entspricht den Anforderungen der EN 60950 / IEC 60950. Angeschlossene
Geräte müssen die zutreffenden Sicherheitsbestimmungen erfüllen.

2 Id:0900d8058059c23c DN9812734
Issue 8-0
Activating and Testing BSS5050, BSS10118,
BSS11116 and BSS8085: Dual Band Network Opera-

Table of Contents
This document has 22 pages.

Summary of changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

1 Activating and testing Dual Band Network Operation (GSM 900/1800, GSM
800/1900, GSM 800/1800, and PGSM 900/EGSM 900) . . . . . . . . . . . . . 6
1.1 Activating Dual Band Network Operation (GSM 900/1800) . . . . . . . . . . . 6
1.2 Testing Dual Band Network Operation (GSM 900/1800). . . . . . . . . . . . . 7
1.3 Activating Dual Band Network Operation (GSM 800/1900) . . . . . . . . . . . 9
1.4 Testing Dual Band Network Operation (GSM 800/1900). . . . . . . . . . . . 10
1.5 Activating Dual Band Network Operation (GSM 800/1800) . . . . . . . . . . 12
1.6 Testing Dual Band Network Operation (GSM 800/1800). . . . . . . . . . . . 13
1.7 Activating Dual Band Network Operation (PGSM 900/EGSM 900) . . . . 14
1.8 Testing Dual Band Network Operation (PGSM 900/EGSM 900). . . . . . 15

2 Deactivating and testing Dual Band Network Operation (GSM 900/1800,


GSM 800/1900 and GSM 800/1800) . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
2.1 Deactivating and testing Dual Band Network Operation (GSM 900/1800)
18
2.2 Deactivating and testing Dual Band Network Operation (GSM 800/1900)
19
2.3 Deactivating and testing Dual Band Network Operation (GSM 800/1800)
21

DN9812734 Id:0900d8058059c23c 3
Issue 8-0
Activating and Testing BSS5050, BSS10118,
BSS11116 and BSS8085: Dual Band Network Opera-

4 Id:0900d8058059c23c DN9812734
Issue 8-0
Activating and Testing BSS5050, BSS10118, Summary of changes
BSS11116 and BSS8085: Dual Band Network Opera-

Summary of changes
Changes between document issues are cumulative. Therefore, the latest document
issue contains all changes made to previous issues.

Changes made between issues 8 and 7


The TV commands have been replaced with TP commands in the activation and deac-
tivation instructions.
References to NetAct and MEFICO have been added.

Changes made between issues 7 and 6


The document has been revised throughout to comply with the latest documentation
standards. No changes have been made due to changes in software. Document name
changed to Activating and Testing BSS5050, BSS10118, BSS11116 and BSS8085:
Dual Band Network Operation.

Changes made between issues 6 and 5–1


Colons added to ZEAM and ZEAC commands.

DN9812734 Id:0900d8058059c233 5
Issue 8-0
Activating and testing Dual Band Network Operation Activating and Testing BSS5050, BSS10118,
(GSM 900/1800, GSM 800/1900, GSM 800/1800, and BSS11116 and BSS8085: Dual Band Network Opera-

1 Activating and testing Dual Band Network


Operation (GSM 900/1800, GSM 800/1900,
GSM 800/1800, and PGSM 900/EGSM 900)
The activation of different Dual Band software products is mutually exclusive and only
one of the Dual Band parameters can be activated to the FIFILE.
There are no files involved.
When activating and deactivating Dual Band Network Operation, see the MMLs and
parameters in the description of Dual Band Network Operation.
For deactivation instructions, see Deactivating and testing Dual Band Network Opera-
tion (GSM 900/1800, GSM 800/1900 and GSM 800/1800).

Before you start


Make sure that the following network elements are available:
• one MSC, releases M7A + CN M7_1686, M7B + CN M7_1713 or later
• one BSC
• two BTSs supporting GSM 900 and GSM 1800, or GSM 800 and GSM 1900, or
GSM 800 and GSM 1800 frequency bands, supporting in releases B10, DF3.0 or
later
• one MS (either dual band or tri-band):
• a dual band MS supporting GSM 900 and GSM 1800, or GSM 800 (supporting
in MetroSite CXM3.0 and in UltraSite CX3.0) and GSM 1900 frequency bands
• a tri-band MS supporting PGSM 900, EGSM 900 (supporting in releases DF3,
without ARFCN 0, and DF4, with ARFCN 0) and GSM 1800 frequency bands

1.1 Activating Dual Band Network Operation (GSM 900/1800)


Before you start
To test the activation of Dual Band Network Operation, use the power budget handover
(PBGT HO).
Make sure that the following BTSs are available:
BTS1 Accessed cell, allocated from GSM 900 band, adjacent to BTS2.
ARFCN allocation according to MS properties (dual band, tri band).
BTS2 Allocated from GSM 1800, adjacent cell to BTS1.
The handovers to be made between GSM 900 and GSM 1800 cells are power budget
handovers with negative margins. For more information on power budget handovers,
see RF Power Control and Handover Algorithm.
g These values are only for test purposes. The original parameter values should be
restored after testing.

6 Id:0900d8058059c236 DN9812734
Issue 8-0
Activating and Testing BSS5050, BSS10118, Activating and testing Dual Band Network Operation
BSS11116 and BSS8085: Dual Band Network Opera- (GSM 900/1800, GSM 800/1900, GSM 800/1800, and

Steps

1 Tune the BTS1 and BTS2 to a proper frequency band (BTS1 <-> GSM 900, BTS2 <-
> GSM 1800).

2 Set the multiband reporting of BTS1 to 1 (EQM).


ZEQM:BTS=1:MBR=1;

3 Set the multiband reporting of BTS2 to 1 (EQM).


ZEQM:BTS=2:MBR=1;

4 Set the early sending indication of BTS1 to ON (EQM).


ZEQM:BTS=1:ESI=Y;

5 Set the early sending indication of BTS2 to ON (EQM).


ZEQM:BTS=2:ESI=Y;

6 Define BTS2 to be adjacent to BTS1 (EAC).


ZEAC:BTS=1::ABTS=2;

7 Define the BTS1 to be adjacent to BTS2 (EAC).


ZEAC:BTS=2::ABTS=1;

8 Take into account the adjacencies on the other band of BTS1 (EQF).
ZEQF:BTS=1:DBC=Y;

9 Take into account the adjacencies on the other band of BTS2 (EQF).
ZEQF:BTS=2:DBC=Y;

Further information
Next, test Dual Band Network Operation (GSM 900/1800).

1.2 Testing Dual Band Network Operation (GSM 900/1800)


Steps

1 Enable the PBGT HO in BTS1 (EHG).


ZEHG:BTS=1:EPB=Y,HPP=6;

2 Enable the PBGT HO in BTS2 (EHG).


ZEHG:BTS=2:EPB=Y,HPP=6;

DN9812734 Id:0900d8058059c236 7
Issue 8-0
Activating and testing Dual Band Network Operation Activating and Testing BSS5050, BSS10118,
(GSM 900/1800, GSM 800/1900, GSM 800/1800, and BSS11116 and BSS8085: Dual Band Network Opera-

3 Set the value of the PBGT HO margin from cell BTS1 to adjacent cell BTS2 to —24
dB to trigger the PBGT HO (EAM).
ZEAM:BTS=1::ABTS=2::PMRG=-24;
g The existing value of PBGT HO margin should be restored after the test.

4 Set the value of the PBGT HO margin from cell BTS2 to adjacent cell BTS1 to -24
dB to trigger the PBGT HO (EAM).
ZEAM:BTS=2::ABTS=1::PMRG=-24;
g The existing value of PBGT HO margin should be restored after the test.
Expected outcome
• Dual Band Network Operation is activated in the BSC.
• A call is set up to the GSM 900 cell, and successive handovers between GSM 900
and GSM 1800 cells are made.
• The test results are verified from the BSC Level Clear Code (PM) Measurements
that indicate the number of successful handovers.

5 Modify BSC Level Clear Code (PM) Measurement (TPM).


ZTPM:MEASUR,CC_PM:<measurement day>,<measurement
interval><output interval>;

6 Start the measurement (TPS).


ZTPS:MEASUR,CC_PM:<start date>,<stop date>;

7 Wait until the measurement is enabled.

8 Interrogate BSC Level Clear Code (PM) Measurement (TPI).


ZTPI:MEASUR,CC_PM;

Expected outcome
The administrative state is UNLOCKED and the operational state is ENABLED.

9 Establish a call to BTS1.


The BSC receives radio link measurements which trigger handovers between BTS1 and
BTS2.

10 Wait for two minutes.

11 Disconnect the call.

8 Id:0900d8058059c236 DN9812734
Issue 8-0
Activating and Testing BSS5050, BSS10118, Activating and testing Dual Band Network Operation
BSS11116 and BSS8085: Dual Band Network Opera- (GSM 900/1800, GSM 800/1900, GSM 800/1800, and

12 Verify the success level of the power budget handovers by using the BSC Level
Clear Code (PM) Measurement.
At the end of the measurement period, check the measurement file in Nokia NetAct or
using the MEFICO tool. For more information, see:
• Reporter and Performance Management Principlesin NetAct documentation
• Converting BSC Measurement and Observation Files with MEFICO

Expected outcome
The counter 051013 INTERNAL_INTER_HO_SUCCESS is updated in both cells.

13 Stop BSC Level Clear Code (PM) Measurement (TPE).


ZTPE:MEASUR,CC_PM;

Expected outcome
The administrative state is now LOCKED and the operational state is DISABLED.

1.3 Activating Dual Band Network Operation (GSM 800/1900)


Before you start
To test the activation of Dual Band Network Operation, use the power budget handover
(PBGT HO).
Make sure that the following BTSs are available:
BTS1 Accessed cell, allocated from GSM 800 band, adjacent to BTS2.
BTS2 Allocated from GSM 1900, adjacent cell to BTS1.
The handovers to be made between GSM 800 and GSM 1900 cells are power budget
handovers with negative margins. For more information, see RF Power Control and
Handover Algorithm.
g These values are only for test purposes. The original parameter values should be
restored after testing.

Steps

1 Tune BTS1 and BTS2 to a proper frequency band (BTS1 <-> GSM 800, BTS2 <->
GSM 1900).

2 Set the multiband reporting of BTS1 to 1 (EQM).


ZEQM:BTS=1:MBR=1;

3 Set the multiband reporting of BTS2 to 1 (EQM).


ZEQM:BTS=2:MBR=1;

4 Set the early sending indication of BTS1 to ON (EQM).


ZEQM:BTS=1:ESI=Y;

DN9812734 Id:0900d8058059c236 9
Issue 8-0
Activating and testing Dual Band Network Operation Activating and Testing BSS5050, BSS10118,
(GSM 900/1800, GSM 800/1900, GSM 800/1800, and BSS11116 and BSS8085: Dual Band Network Opera-

5 Set the early sending indication of BTS2 to ON(EQM).


ZEQM:BTS=2:ESI=Y;

6 Define BTS2 to be adjacent to BTS1 (EAC).


ZEAC:BTS=1::ABTS=2;

7 Define BTS1 to be adjacent to BTS2 (EAC)


ZEAC:BTS=2::ABTS=1;

8 Take into account the adjacencies on other band of BTS1 (EQF).


ZEQF:BTS=1:DBC=Y;

9 Take into account the adjacencies on other band of BTS2 (EQF).


ZEQF:BTS=2:DBC=Y;

Further information
Next, test Dual Band Network Operation (GSM 800/1900).

1.4 Testing Dual Band Network Operation (GSM 800/1900)


Steps

1 Enable the PBGT HO in BTS1 (EHG).


ZEHG:BTS=1:EPB=Y,HPP=6;

2 Enable the PBGT HO in BTS2 (EHG).


ZEHG:BTS=2:EPB=Y,HPP=6;

3 Set the value of the PBGT HO margin from cell BTS1 to adjacent cell BTS2 to —24
dB to trigger the PBGT HO (EAM).
ZEAM:BTS=1::ABTS=2::PMRG=-24;
g The existing value of PBGT HO margin should be restored after the test.

4 Set the PBGT HO margin from cell BTS2 to adjacent cell BTS1 to value -24 dB to
trigger the PBGT HO (EAM).
ZEAM:BTS=2::ABTS=1::PMRG=-24;
g The existing value of PBGT HO margin should be restored after the test.
Expected outcome
• Dual Band Network Operation is activated in the BSC.

10 Id:0900d8058059c236 DN9812734
Issue 8-0
Activating and Testing BSS5050, BSS10118, Activating and testing Dual Band Network Operation
BSS11116 and BSS8085: Dual Band Network Opera- (GSM 900/1800, GSM 800/1900, GSM 800/1800, and

• A call is set up to the GSM 800 cell, and successive handovers between GSM 800
and GSM 1900 cells are made.
• The test results are verified from the BSC clear code measurements that indicate
the number of successful handovers.

5 Modify BSC Level Clear Code (PM) Measurement (TPM).


ZTPM:MEASUR,CC_PM:<measurement day>,<measurement
interval>,<output interval>;

6 Start the measurement (TPS).


ZTPS:MEASUR,CC_PM:<start date>,<stop date>;

7 Wait until the measurement is enabled.

8 Interrogate BSC Level Clear Code (PM) Measurement (TPI).


ZTPI:MEASUR,CC_PM;

Expected outcome
The administrative state is UNLOCKED and the operational state is ENABLED.

9 Establish a call to BTS1.


The BSC receives radio link measurements which trigger handovers between BTS1 and
BTS2.

10 Wait for two minutes.

11 Disconnect the call.

12 Verify the success level of handovers by using BSC Level Clear Code (PM) Mea-
surement.
At the end of the measurement period, check the measurement file in Nokia NetAct or
using the MEFICO tool. For more information, see:
• Reporter and Performance Management Principles in NetAct documentation
• Converting BSC Measurement and Observation Files with MEFICO

Expected outcome
The counter 051013 INTERNAL_INTER_HO_SUCCESS is updated in both cells.

13 Stop BSC Level Clear Code (PM) Measurement (TPE).


ZTPE:MEASUR,CC_PM;

DN9812734 Id:0900d8058059c236 11
Issue 8-0
Activating and testing Dual Band Network Operation Activating and Testing BSS5050, BSS10118,
(GSM 900/1800, GSM 800/1900, GSM 800/1800, and BSS11116 and BSS8085: Dual Band Network Opera-

1.5 Activating Dual Band Network Operation (GSM 800/1800)


Before you start
To test the activation of Dual Band Network Operation, use the power budget handover
(PBGT HO).
Make sure that the following BTSs are available:
BTS1 accessed cell, allocated from GSM 800 band, adjacent to BTS2
BTS2 allocated from GSM 1800, adjacent cell to BTS1
The handovers to be made between GSM 800 and GSM 1800 cells are power budget
handovers with negative margins. For more information, see RF Power Control and
Handover Algorithm.
g These values are only for test purposes. The original parameter values should be
restored after testing.
Make sure that the parameter GSM800_1800_USAGE is activated. You can check the
activation by using the command
ZWOS:2,738;
Note that it is not possible to modify the value of the parameter.

Steps

1 Tune BTS1 and BTS2 to a proper frequency band (BTS1 <-> GSM 800, BTS2 <->
GSM 1800).

2 Set the multiband reporting of BTS1 to 1 (EQM).


ZEQM:BTS=1:MBR=1;

3 Set the multiband reporting of BTS2 to 1 (EQM).


ZEQM:BTS=2:MBR=1;

4 Set the early sending indication of BTS1 on (EQM).


ZEQM:BTS=1:ESI=Y;

5 Set the early sending indication of BTS2 on (EQM).


ZEQM:BTS=2:ESI=Y;

6 Define BTS2 to be adjacent to BTS1 (EAC).


ZEAC:BTS=1::ABTS=2;

7 Define BTS1 to be adjacent to BTS2 (EAC)


ZEAC:BTS=2::ABTS=1;

12 Id:0900d8058059c236 DN9812734
Issue 8-0
Activating and Testing BSS5050, BSS10118, Activating and testing Dual Band Network Operation
BSS11116 and BSS8085: Dual Band Network Opera- (GSM 900/1800, GSM 800/1900, GSM 800/1800, and

8 Take into account the adjacencies on other band of BTS1 (EQF).


ZEQF:BTS=1:DBC=Y;

9 Take into account the adjacencies on other band of BTS2 (EQF).


ZEQF:BTS=2:DBC=Y;

Further information
Next, test Dual Band Network Operation (GSM 800/1800).

1.6 Testing Dual Band Network Operation (GSM 800/1800)


Steps

1 Enable the PBGT HO in BTS1 (EHG).


ZEHG:BTS=1:EPB=Y,HPP=6;

2 Enable the PBGT HO in BTS2 (EHG).


ZEHG:BTS=2:EPB=Y,HPP=6;

3 Set the value of the PBGT HO margin from cell BTS1 to adjacent cell BTS2 to -24
dB to trigger the PBGT HO (EAM).
ZEAM:BTS=1::ABTS=2::PMRG=-24;
g The existing value of PBGT HO margin should be restored after the test.

4 Set the value of the PBGT HO margin from cell BTS2 to adjacent cell BTS1 to -24
dB to trigger the PBGT HO (EAM).
ZEAM:BTS=2::ABTS=1::PMRG=-24;
g The existing value of PBGT HO margin should be restored after the test.
Expected outcome
• Dual Band Network Operation is activated in the BSC.
• A call is set up to the GSM 800 cell, and successive handovers between GSM 800
and GSM 1800 cells are made.
• The test results are verified from the BSC clear code measurements that indicate
the number of successful handovers.

5 Modify BSC Level Clear Code (PM) Measurement (TPM).


ZTPM:MEASUR,CC_PM:<measurement day>,<measurement
interval>,<output interval>;

6 Start the measurement (TPS).


ZTPS:MEASUR,CC_PM:<start date>,<stop date>;

DN9812734 Id:0900d8058059c236 13
Issue 8-0
Activating and testing Dual Band Network Operation Activating and Testing BSS5050, BSS10118,
(GSM 900/1800, GSM 800/1900, GSM 800/1800, and BSS11116 and BSS8085: Dual Band Network Opera-

7 Wait until the measurement is enabled.

8 Interrogate BSC Level Clear Code (PM) Measurement (TPI).


ZTPI:MEASUR,CC_PM;

9 Establish a call to BTS1.


The BSC receives radio link measurements which trigger handovers between BTS1 and
BTS2.

10 Wait for two minutes.

11 Disconnect the call.

12 Verify the success level of handovers by using BSC Level Clear Code (PM) Mea-
surement.
At the end of the measurement period, check the measurement file in Nokia NetAct or
using the MEFICO tool. For more information, see:
• Reporter and Performance Management Principles in NetAct documentation
• Converting BSC Measurement and Observation Files with MEFICO

Expected outcome
The counter 051013 INTERNAL_INTER_HO_SUCCESS is updated in both cells.

13 Stop BSC Level Clear Code (PM) Measurement (TPE).


ZTPE:MEASUR,CC_PM;

1.7 Activating Dual Band Network Operation (PGSM


900/EGSM 900)
You can test this functionality to see if the traffic control between PGSM 900 and EGSM
900 is activated in the BSC. Set up a call to a PGSM 900 cell and make successive han-
dovers between PGSM 900 and EGSM 900 cells. You can verify the test results from
the BSC clear code measurements that indicate the number of successful handovers.

Before you start


To test the activation of Dual Band Network Operation, use the power budget handover
(PBGT HO).
Make sure that the following network elements are available:
• one MSC
• one BSC
• two BTSs: one PGSM 900 BTS and one EGSM 900 BTS supporting in releases DF3
(without ARFCN 0) and DF4 (with ARFCN 0)
• one MS capable to operate in both PGSM 900 and EGSM 900 frequency bands

14 Id:0900d8058059c236 DN9812734
Issue 8-0
Activating and Testing BSS5050, BSS10118, Activating and testing Dual Band Network Operation
BSS11116 and BSS8085: Dual Band Network Opera- (GSM 900/1800, GSM 800/1900, GSM 800/1800, and

The BTSs used in the testing are the following:


BTS1 accessed cell, allocated from PGSM 900 band, adjacent to BTS2
BTS2 allocated from EGSM 900 band, adjacent cell to BTS1
The handovers to be made between PGSM 900 and EGSM 900 cells are power budget
handovers with negative margins. For more information, see RF Power Control and
Handover Algorithm.
g These values are only for test purposes. The original parameter values should be
restored after testing.
Make sure that the parameter COMMON_BCCH_EGSM900 is activated. You can check the
activation by using the command
ZWOS:2,664;
Note that it is not possible to modify the value of the parameter.

Steps

1 Tune BTS1 and BTS2 to a proper frequency band (BTS1 <-> PGSM 900, BTS2 <->
EGSM 900).

2 Define BTS2 to be adjacent to BTS1 (EAC).


ZEAC:BTS=1::ABTS=2;

3 Define BTS1 to be adjacent to BTS2 (EAC).


ZEAC:BTS=2::ABTS=1;

Further information
Next, test Dual Band Network Operation (PGSM 900/EGSM 900).

1.8 Testing Dual Band Network Operation (PGSM 900/EGSM


900)
Steps

1 Enable the PBGT HO in BTS1 (EHG).


ZEHG:BTS=1:EPB=Y,HPP=6;

2 Enable the PBGT HO in BTS2 (EHG).


ZEHG:BTS=2:EPB=Y,HPP=6;

3 Set the value of the PBGT HO margin from cell BTS1 to adjacent cell BTS2 to -24
dB to trigger the PBGT HO (EAM).
ZEAM:BTS=1::ABTS=2::PMRG=-24;
g The existing value of PBGT HO margin should be restored after the test.

DN9812734 Id:0900d8058059c236 15
Issue 8-0
Activating and testing Dual Band Network Operation Activating and Testing BSS5050, BSS10118,
(GSM 900/1800, GSM 800/1900, GSM 800/1800, and BSS11116 and BSS8085: Dual Band Network Opera-

4 Set the value of the PBGT HO margin from cell BTS2 to adjacent cell BTS1 to -24
dB to trigger the PBGT HO (EAM).
ZEAM:BTS=2::ABTS=1::PMRG=-24;
g The existing value of PBGT HO margin should be restored after the test.
Expected outcome
• Dual Band Network Operation is activated in the BSC.
• A call is set up to the PGSM 900 cell, and successive handovers between PGSM
900 and EGSM 900 cells are made.
• The test results are verified from the BSC clear code measurements that indicate
the number of successful handovers.

5 Modify BSC Level Clear Code (PM) Measurement (TPM).


ZTPM:MEASUR,CC_PM:<measurement day>,<measurement
interval>,<output interval>;

6 Start the measurement (TPS).


ZTPS:MEASUR,CC_PM:<start date>,<stop date>;

7 Wait until the measurement is enabled.

8 Interrogate BSC Level Clear Code (PM) Measurement (TPI).


ZTPI:MEASUR,CC_PM;

9 Establish a call to BTS1.


The BSC receives radio link measurements which could trigger handovers between
BTS1 and BTS2.

10 Wait for two minutes.

11 Disconnect the call.

12 Verify the success level of handovers by using BSC Level Clear Code (PM) Mea-
surement.
At the end of the measurement period, check the measurement file in Nokia NetAct or
using the MEFICO tool. For more information, see:
• Reporter and Performance Management Principles in NetAct documentation
• Converting BSC Measurement and Observation Files with MEFICO

Expected outcome
The counter 051013 INTERNAL_INTER_HO_SUCCESS is updated in both cells.

16 Id:0900d8058059c236 DN9812734
Issue 8-0
Activating and Testing BSS5050, BSS10118, Activating and testing Dual Band Network Operation
BSS11116 and BSS8085: Dual Band Network Opera- (GSM 900/1800, GSM 800/1900, GSM 800/1800, and

13 Stop BSC Level Clear Code (PM) Measurement (TPE).


ZTPE:MEASUR,CC_PM;

DN9812734 Id:0900d8058059c236 17
Issue 8-0
Deactivating and testing Dual Band Network Operation Activating and Testing BSS5050, BSS10118,
(GSM 900/1800, GSM 800/1900 and GSM 800/1800) BSS11116 and BSS8085: Dual Band Network Opera-

2 Deactivating and testing Dual Band Network


Operation (GSM 900/1800, GSM 800/1900 and
GSM 800/1800)

2.1 Deactivating and testing Dual Band Network Operation


(GSM 900/1800)
For a description, see Dual Band Network Operation.
For activation instructions, see Activating and testing Dual Band Network Operation
(GSM 900/1800, GSM 800/1900 and GSM 800/1800, PGSM 900/EGSM 900).

Steps

1 Disable the adjacencies on other band for BTS1 (EQF).


ZEQF:BTS=1:DBC=N;
where
BTS=1 is the GSM 900 cell identification

2 Disable the adjacencies on other band for BTS2 (EQF).


ZEQF:BTS=2:DBC=N;
where
BTS=2 is the GSM 1800 cell identification

3 Modify the counters of BSC Level Clear Code (PM) Measurement (TPM).
ZTPM:MEASUR,CC_PM:<measurement day>,<measurement
interval>,<output interval>;

4 Start the measurement (TPS).


ZTPS:MEASUR,CC_PM:<start date>,<stop date>;

5 Wait until the measurement is enabled.

6 Interrogate BSC Level Clear Code (PM) Measurement (TPI).


ZTPI:MEASUR,CC_PM;

7 Establish a call to BTS1.


The BSC receives radio link measurements which could trigger handovers between
BTS1 and BTS2.

8 Wait for two minutes.

18 Id:0900d8058059c239 DN9812734
Issue 8-0
Activating and Testing BSS5050, BSS10118, Deactivating and testing Dual Band Network Operation
BSS11116 and BSS8085: Dual Band Network Opera- (GSM 900/1800, GSM 800/1900 and GSM 800/1800)

9 Disconnect the call.

10 Restore the original PBGT HO margin values (EAM).


ZEAM:BTS=1::ABTS=2::PMRG=nn;
where
BTS=1 is the GSM 900 cell identification
ABTS=2 is the GSM 1800 cell identification
nn is the original value
ZEAM:BTS=2::ABTS=1::PMRG=nn;
where
BTS=2 is the GSM 1800 cell identification
ABTS=1 is the GSM 900 cell identification
nn is the original value

11 Verify the success level of handovers by using BSC Level Clear Code (PM) Mea-
surement.
At the end of the measurement period, check the measurement file in Nokia NetAct or
using the MEFICO tool. For more information, see:
• Reporter and Performance Management Principles in NetAct documentation
• Converting BSC Measurement and Observation Files with MEFICO

Expected outcome
The counter 051013 INTERNAL_INTER_HO_SUCCESS is not updated (no handovers
are made).

12 Stop BSC Level Clear Code (PM) Measurement (TPE).


ZTPE:MEASUR,CC_PM;

2.2 Deactivating and testing Dual Band Network Operation


(GSM 800/1900)
Steps

1 Disable the adjacencies on other band for BTS1 (EQF).


ZEQF:BTS=1:DBC=N;
where
BTS=1 is the GSM 800 cell identification

2 Disable the adjacencies on other band for BTS2 (EQF).


ZEQF:BTS=2:DBC=N;

DN9812734 Id:0900d8058059c239 19
Issue 8-0
Deactivating and testing Dual Band Network Operation Activating and Testing BSS5050, BSS10118,
(GSM 900/1800, GSM 800/1900 and GSM 800/1800) BSS11116 and BSS8085: Dual Band Network Opera-

where
BTS=2 is the GSM 1900 cell identification

3 Modify the counters of BSC Level Clear Code (PM) Measurement (TPM).
ZTPM:MEASUR,CC_PM:<measurement day>,<measurent interval>,<output
interval>;

4 Start the measurement (TPS).


ZTPS:MEASUR,CC_PM:<start date>,<stop date>;

5 Wait until the measurement is enabled.

6 Interrogate BSC Level Clear Code (PM) Measurement (TPI).


ZTPI:MEASUR,CC_PM;

7 Establish a call to BTS1.


The BSC receives radio link measurements which could trigger handovers between
BTS1 and BTS2.

8 Wait for two minutes.

9 Disconnect the call.

10 Restore the original PBGT HO margin values (EAM).


ZEAM:BTS=1::ABTS=2::PMRG=nn;
where
BTS=1 is the GSM 800 cell identification
ABTS=2 is the GSM 1900 cell identification
nn is the original value
ZEAM:BTS=2::ABTS=1::PMRG=nn;
where
BTS=2 is the GSM 1900 cell identification
ABTS=1 is the GSM 800 cell identification
nn is the original value

11 Verify the success level of handovers by using BSC Level Clear Code (PM) Mea-
surement.
At the end of the measurement period, check the measurement file in Nokia NetAct or
using the MEFICO tool. For more information, see:
• Reporter and Performance Management Principles in NetAct documentation

20 Id:0900d8058059c239 DN9812734
Issue 8-0
Activating and Testing BSS5050, BSS10118, Deactivating and testing Dual Band Network Operation
BSS11116 and BSS8085: Dual Band Network Opera- (GSM 900/1800, GSM 800/1900 and GSM 800/1800)

• Converting BSC Measurement and Observation Files with MEFICO

Expected outcome
The counter 051013 INTERNAL_INTER_HO_SUCCESS is not updated (no handovers
are made).

12 Stop BSC Level Clear Code (PM) Measurement (TPE).


ZTPE:MEASUR,CC_PM;

2.3 Deactivating and testing Dual Band Network Operation


(GSM 800/1800)
Steps

1 Disable adjacencies on other band for BTS1 (EQF).


ZEQF:BTS=1:DBC=N;
where
BTS=1 is the GSM 800 cell identification

2 Disable adjacencies on other band for BTS2 (EQF).


ZEQF:BTS=2:DBC=N;
where
BTS=2 is the GSM 1800 cell identification

3 Modify the counters of the BSC Level Clear Code (PM) Measurement (TPM).
ZTPM:MEASUR,CC_PM:<measurement day>,<measurent interval>,<output
interval>;

4 Start the measurement (TPS).


ZTPS:MEASUR,CC_PM:<start date>,<stop date>;

5 Wait until the measurement is enabled.

6 Interrogate BSC Level Clear Code (PM) Measurement (TPI).


ZTPI:MEASUR,CC_PM;

7 Establish a call to BTS1.


The BSC receives radio link measurements which could trigger handovers between
BTS1 and BTS2.

8 Wait for two minutes.

DN9812734 Id:0900d8058059c239 21
Issue 8-0
Deactivating and testing Dual Band Network Operation Activating and Testing BSS5050, BSS10118,
(GSM 900/1800, GSM 800/1900 and GSM 800/1800) BSS11116 and BSS8085: Dual Band Network Opera-

9 Disconnect the call.

10 Restore the original PBGT HO margin values (EAM).


ZEAM:BTS=1::ABTS=2::PMRG=nn;
where
BTS=1 is the GSM 800 cell identification
ABTS=2 is the GSM 1800 cell identification
nn is the original value
ZEAM:BTS=2::ABTS=1::PMRG=nn;
where
BTS=2 is the GSM 1800 cell identification
ABTS=1 is the GSM 800 cell identification
nn is the original value

11 Verify the success level of handovers by using BSC Level Clear Code (PM) Mea-
surement.
At the end of the measurement period, check the measurement file in Nokia NetAct or
using the MEFICO tool. For more information, see:
• Reporter and Performance Management Principles in NetAct documentation
• Converting BSC Measurement and Observation Files with MEFICO

Expected outcome
The counter 051013 INTERNAL_INTER_HO_SUCCESS is not updated (no handovers
are made).

12 Stop BSC Level Clear Code (PM) Measurement (TPE).


ZTPE:MEASUR,CC_PM;

22 Id:0900d8058059c239 DN9812734