Technical Data

PanelView Plus Specifications


Catalog Numbers 2711P, 2711PC

Topic Page
Environmental Specifications 2
Certifications 3
PanelView Plus 6 Terminals 4
PanelView Plus 400 and 600 Terminals 11
PanelView Plus Compact Terminals 15
External Power Supply 18
HMI Software 20
Communication Cables 23
Migration Hardware 27
Additional Resources 28

PanelView Plus Family PanelView Plus HMI terminals are used for applications with a need to monitor,
control, and display information graphically, allowing operators to quickly
understand the status of their application. All PanelView Plus applications are
programmed with FactoryTalk View Studio for Machine Edition (ME) software
and have FactoryTalk View ME Station runtime installed on each terminal.

This family provides a broad range of rugged terminals offering these features:
• Premier integration with the Integrated Architecture platform
• Scalable 4- to 15-inch displays with touch screen, keypad, or both for input
• Common development software
• Real-time monitoring of a terminal's displays via a web browser

Use this document along with the Visualization Solutions Selection Guide,
publication VIEW-SG001, to make decisions on the visualization solutions best
suited for your system requirements.
2 PanelView Plus Specifications

Environmental The environmental certifications apply to all PanelView Plus terminals:


Specifications • PanelView Plus 6 terminals including logic, communication modules,
and 700, 1000, 1250, 1500 display modules
• PanelView Plus 400 and 600 terminals
• PanelView Plus Compact 400, 600, and 1000 terminals

Table 1 - Environmental Specifications - PanelView Plus Terminals


Attribute 2711P, 2711PC
Temperature, operating 0…55 °C (32…131 °F)
Temperature, storage -25…70 °C (-13…158 °F)
Heat dissipation
400, 600 85 BTU/hr
700, 1000, 1250, 1500 240 BTU /hr
Relative humidity 5...95% noncondensing
Vibration 0.012 in. peak-peak 10…57 Hz
2 g at 57…500 Hz
Altitude, operating 2000 m (6561 ft)
Shock, operating 15 g at 11 ms
Shock, nonoperating 30 g at 11 ms
Enclosure ratings NEMA Type 12, 13, 4X (indoor use only), IEC IP54, IP65
Airborne contaminants For PVP/PVP-CE conformal-coated PCBA level products:
ANSI/ISA S71.04 - 1985 Severity Level G3
EN60654-4: 1998 Class 3

Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010


PanelView Plus Specifications 3

Certifications The certifications apply to all PanelView Plus terminals:


• PanelView Plus 6 terminals including logic, communication modules,
and 700, 1000, 1250, 1500 display modules
• PanelView Plus 400 and 600 terminals
• PanelView Plus Compact 400, 600, and 1000 terminals
Table 2 - Certifications - PanelView Plus Terminals

Certification(1) 2711P, 2711PC

c-UL-us UL Listed Industrial Control Equipment, certified for US and Canada. See UL
File E10314.

UL Listed Industrial Control Equipment for use in:


• Class I, Div 2, Groups A, B, C, D
• Class I, Zone 2, Group IIC (2)
• Class II, Div 2 Groups F, G
• Class III Hazardous Locations
CE (EMC) European Union 2004/108/EC EMC Directive, compliant with:
• EN 61000-6-2; Industrial Immunity
• EN 61000-6-4; Industrial Emissions
CE (LVD) European Union 2006/95/EC Low Voltage Directive, compliant with:
• EN 61131-2; Programmable Controllers
C-Tick Australian Radiocommunications Act, compliant with:
AS/NZS CISPR 11; Industrial Emissions

Marine(3) Products identified with the suffix M in the catalog number are certified to the
requirements of one or more marine societies.
For additional marine-certified components, refer to the Product Certification
link below this table.

(1) When marked. See the Product Certification link at http://www.ab.com for Declarations of Conformity,
Certificates, and other certification details.
(2) Applies only to the 1250 high-bright display module.
(3) The 700 and 1000 display modules are marked as marine-certified.

Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010


4 PanelView Plus Specifications

PanelView Plus 6 Terminals The PanelView Plus 6 terminals use modular components allowing for flexible
configuration, installation, and upgrades. Factory-assembled terminals, with a
display module (700, 1000, 1250, 1500) and logic module, are available as a
single catalog number or as separate components for field installation. Optional
communication modules can be ordered for additional network communication.
The field-replaceable 6.5, 10.4, 12.1, and 15.1-in. flat-panel color displays come
with keypad, touch screen, or keypad/touch-screen input. Other display options
are available to meet more stringent environmental conditions:
• High-bright display module for outdoor applications
• Conformal-coated displays
• Marine-certified displays
• Displays with built-in antiglare overlays
The high-performance logic module runs the Windows CE 6.0 operating system
allowing you to run HMI applications with the ability to also access the desktop.
For users with more complex application requirements, the platform and logic
module can be ordered with optional, extended features and file viewers.
Table 3 - Logic Module Features
Features Description
High memory capacity 512 MB nonvolatile flash and 512 MB RAM
Power input AC or DC
Network interface For optional DH+, DH-485, or ControlNet communication module
Communication ports Ethernet, RS-232 serial
USB ports • 2 USB host ports for connecting a USB mouse, keyboard,
printer, and USB flash drives that are hot swappable
• 1 USB device port for connecting a host personal computer
Secure Digital (SD) card slot Hot-swappable card slot supports 1784-CDx SD cards for
transferring files, upgrading firmware, or logging data
Operating system All terminals run the Windows CE 6.0 operating system (OS)
providing OS functionality needed for most users needs:
• FTP server
• VNC client/server
• PDF reader
• Active X controls
• Third-party device support
Additional functionality is available by ordering terminals with
optional, extended features:
• Internet Explorer web browser
Optional • Remote desktop connection
Extended Features • Media player
• Microsoft file viewers for PowerPoint, Excel, and Word
• WordPad text editor
• PDF reader
FactoryTalk View software • FactoryTalk View Machine Edition software, version 6.0 or later, is
preloaded and activated on each terminal
• Single license support for FactoryTalk ViewPoint software, version
1.2 or later, gives remote users access to a terminal’s displays via
standard web browser
• HMI applications are developed with FactoryTalk View Studio for
Machine Edition software, which is purchased separately
Reset and Default Switches Provide easy access to diagnostic and repair operations.

For a complete listing of catalog number selections, refer to the Visualization


Solutions Selection Guide, publication VIEW-SG001.

Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010


PanelView Plus Specifications 5

Technical Specifications - PanelView Plus 6 Terminals


Table 4 - Technical Specifications - PanelView Plus 6 Terminals

700 Color(1) 1000 Color(1) 1250 Color(1) 1500 Color(1)


Attribute 2711P-K7C4Dx, 2711P-T7C4Dx, 2711P-K10C4Dx, 2711P-T10C4Dx, 2711P-K12C4Dx, 2711P-T12C4Dx, 2711P-K15C4Dx, 2711P-T15C4Dx,
2711P-B7C4Dx, 2711P-K7C4Ax, 2711P-B10C4Dx, 2711P-K10C4Ax, 2711P-B12C4Dx, 2711P-K12C4Ax, 2711P-B15C4Dx, 2711P-K15C4Ax,
2711P-T7C4Ax, 2711P-B7C4Ax 2711P-T10C4Ax, 2711P-B10C4Ax 2711P-T12C4Ax, 2711P-B12C4Ax 2711P-T15C4Ax, 2711P-B15C4Ax

Operator input Keypad, Touch, or Key/Touch Keypad, Touch, or Key/Touch Keypad, Touch, or Key/Touch Keypad, Touch, or Key/Touch

Display type Color active-matrix TFT Color active-matrix TFT Color active-matrix TFT Color active-matrix TFT

Display size 6.5 in. 10.4 in. 12.1 in. 15 in.

Display area (WxH) 132 x 99 mm (5.2 x 3.9 in.) 211 x 158 mm (8.3 x 6.2 in.) 246 x 184 mm (9.7 x 7.2 in.) 304 x 228 mm (12.0 x 9.0 in.)

Resolution 640 x 480, 18-bit color graphics 800 x 600, 18-bit color graphics 1024 x 768, 18-bit color graphics

Luminance 300 cd/m2 Nits 300 cd/m2 Nits(2)

Backlight 50,000 h life, min., field replaceable


Backlight for 1250 high-bright display module is not replaceable
Touch screen 8-wire analog resistive
Actuation: 1 million presses; operating force: 10…110 g
Keypad description Stainless-steel membrane
Numeric, navigation, and function keys
Actuation: 1 million presses; operating force: 340 g
Keypad function keys 22 function keys 32 function keys 40 function keys 40 function keys
F1…F10 and K1…K12 F1…F16 and K1…K16 F1…F20 and K1…K20 F1…F20 and K1…K20
Real-time clock Battery-backed clock timestamps critical data, ±2 minutes per month
Battery life: 4 year min. @ 25 °C (77 °F)
Field-replaceable: cat. no. 2711P-RY2032
Memory 512 MB nonvolatile flash and 512 MB RAM

External storage Secure Digital (SD) card, cat. no.1784-SDx, supported by hot-swappable SD card slot
USB flash drives supported by high-speed, hot-swappable, 2.0 USB host ports
Operating system Windows CE 6.0 operating system with or without extended features/file viewers

Software FactoryTalk View Machine Edition, version 6.0 or later


FactoryTalk ViewPoint, version 1.2 or later
Communication ports Ethernet (10/100 Mbps, Auto-MDI/MDI-X), RS-232, (2) USB host, (1) USB device
Network interface for optional DH+/DH-485, or ControlNet (scheduled or unscheduled) communication module
Input voltage, DC 18…32V DC (24V DC nom)

Power consumption, DC 70 W max (2.9 A at 24V DC)

External power supply Cat. no. 2711P-RSACDIN, Class 2 or Safety Extra-Low Voltage (SELV) power supply for 700 to 1500
DC powered terminals; 85…264V AC, 120VA max
Input voltage, AC 85…264V AC, 47…63 Hz

Power consumption, AC 160VA max

Weight, approx. (3) Keypad: 1.8 kg (4.1 lb) Keypad: 2.8 kg (6.2 lb) Keypad: 3.4 kg (7.5 lb) Keypad: 4.5 kg (9.9 lb)
Touch: 1.7 kg (3.7 lb) Touch: 2.5 kg (5.6 lb) Touch: 3.2 kg (7.0 lb) Touch: 4.2 kg (9.2 lb)

Dimensions (HxWxD), approx. (3) Keypad: 193 x 290 x 55 mm Keypad: 248 x 399 x 55 mm Keypad: 282 x 416 x 55 mm Keypad: 330 x 469 x 65 mm
7.58 x 11.40 x 2.18 in. 9.77 x 15.72 x 2.18 in. 11.12 x 16.36 x 2.18 in. 12.97 x 18.46 x 2.55 in.
Touch: 179 x 246 x 55 mm Touch: 248 x 329 x 55 mm Touch: 282 x 363 x 55 mm Touch: 330 x 416 x 65 mm
7.04 x 9.68 x 2.18 in. 9.77 x 12.97 x 2.18 in. 11.12 x 14.30 x 2.18 in. 12.97 x 16.37 x 2.55 in.

Cutout dimensions (HxWxD) Keypad: 167 x 264 mm Keypad: 224 x 375 mm Keypad: 257 x 390 mm Keypad: 305 x 419 mm
6.57 x 10.39 in. 8.8 x 14.75 in. 10.11 x 15.35 in. 12.0 x 16.5 in.
Touch: 154 x 220 mm Touch: 224 x 305 mm Touch: 257 x 338 mm Touch: 305 x 391 mm
6.08 x 8.67 in. 8.8 x 12.0 in. 10.11 x 13.29 in. 12.0 x 15.4 in.

(1) Replace x in catalog number with an 8 or 9. For catalog numbers ending in 9, the Windows CE operating system includes extended features and file viewers; catalog
numbers ending in 8 do not support these features.
(2) The 1250 high-bright display module, cat. no. 2711P-RDT12H, for outdoor operations, has a luminance of 1000 cd/m2 Nits. The backlight is not replaceable.
(3) Weights and dimensions do not include communication module. Add 95 g (0.21 lb) to the weight for a communication module.

Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010


6 PanelView Plus Specifications

Terminal Dimensions - PanelView Plus 6 Terminals


The table provides overall dimensions and cutout dimensions for the PanelView
Plus 6 terminals. The 1000 keypad and touch terminal is shown for reference.
Other models look similar.

1000 Touch

a
b

1000 Keypad

a
b

Table 5 - PanelView Plus 6 Terminal Dimensions


Terminal Type Width Height Depth a(1) Depth b(2) Cutout Width Cutout Height
290 mm 193 mm 55 mm 83 mm 264 mm 167 mm
700 Keypad or Keypad/Touch 11.40 in. 7.58 in. 2.18 in. 3.27 in. 10.39 in. 6.59 in.
246 mm 179 mm 55 mm 83 mm 220 mm 154 mm
700 Touch 9.68 in. 7.04 in. 2.18 in. 3.27 in. 8.67 in. 6.08 in.
399 mm 248 mm 55 mm 83 mm 375 mm 224 mm
1000 Keypad or Keypad/Touch 15.72 in. 9.77 in. 2.18 in. 3.27 in. 14.75 in. 8.8 in.
329 mm 248 mm 55 mm 83 mm 305 mm 224 mm
1000 Touch 12.97 in. 9.77 in. 2.18 in. 3.27 in. 12.00 in. 8.8 in.
416 mm 282 mm 55 mm 83 mm 390 mm 257 mm
1250 Keypad or Keypad/Touch 16.36 in. 11.12 in. 2.18 in. 3.27 in. 15.35 in. 10.11 in.
363 mm 282 mm 55 mm 83 mm 338 mm 257 mm
1250 Touch 14.30 in. 11.12 in. 2.18 in. 3.27 in. 13.29 in. 10.11 in.
363 mm 282 mm 74 mm 101 mm 338 mm 257 mm
1250 High-bright Touch 14.30 in. 11.12 in. 2.9 in. 3.99 in. 13.29 in. 10.11 in.
469 mm 330 mm 65 mm 93 mm 419 mm 305 mm
1500 Keypad or Keypad/Touch 18.46 in. 12.97 in. 2.55 in. 3.65 in. 16.50 in. 12.00 in.
416 mm 330 mm 65 mm 93 mm 391 mm 305 mm
1500 Touch 16.37 in. 12.97 in. 2.55 in. 3.65 in. 15.40 in. 12.00 in.

(1) Dimension is from display to logic module.


(2) Dimension is from display to communication module.

Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010


PanelView Plus Specifications 7

Accessories - PanelView Plus 6 Terminals


Tables 6…18 lists accessories for the PanelView Plus 6 platform.

Table 6 - Display Modules


Marine Conformal Built-in
Cat. No. Input Type Display Certified Coated Antiglare Overlay
700 Model
2711P-RDK7C Keypad 7-in. color
2711P-RDK7CK Keypad •
2711P-RDT7C Touch
2711P-RDT7CK Touch •
2711P-RDT7CM Touch •
2711P-RDB7C Keypad/Touch
2711P-RDB7CK Keypad/Touch •
2711P-RDB7CM Keypad/Touch •
1000 Model
2711P-RDK10C Keypad 10-4 in. color
2711P-RDT10C Touch
2711P-RDT10CM Touch •
2711P-RDB10C Keypad/Touch
2711P-RDB10CM Keypad/Touch •
1250 Model
2711P-RDK12C Keypad 12.1-in. color
2711P-RDK12CK Keypad •
2711P-RDT12C Touch
2711P-RDT12CK Touch •
2711P-RDT12AG Touch •

2711P-RDT12H(1) Touch

2711P-RDB12C Keypad/Touch
2711P-RDB12CK Keypad/Touch •
1500 Model
2711P-RDK15C Keypad 15-in. color
2711P-RDT15C Touch
2711P-RDT15AG Touch •
2711P-RDB15C Keypad/Touch
(1) This catalog number is a high-bright display module, indicated by the H at end of cat. no., that is designed for
outdoor applications. The high-bright display module can only be used with DC-powered logic modules.

Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010


8 PanelView Plus Specifications

Table 7 - Logic Modules


Power Nonvolatile Flash/ Conformal
Cat. No. Communication Included Software
Input RAM Memory Coated
Without Extended Features
2711P-RP8A AC 512 MB/512 MB • Ethernet • Windows CE 6.0 operating system without
• RS-232 extended features/file viewers
2711P-RP8D DC 512 MB/512 MB • Network interface for • FactoryTalk View Machine Edition runtime,
communication module version 6.0 or later
2711P-RP8DK DC 512 MB/512 MB • • FactoryTalk ViewPoint, version 1.2 or later
With Extended Features
2711P-RP9A AC 512 MB/512 MB • Ethernet • Windows CE 6.0 operating system with
• RS-232 extended features/file viewers
2711P-RP9D DC 512 MB/512 MB • Network interface • FactoryTalk View Machine Edition runtime,
communication module version 6.0 or later
2711P-RP9DK DC 512 MB/512 MB • • FactoryTalk ViewPoint, version 1.2 or later

Table 8 - Communication Modules


Communication
Conformal Marine
Cat. No.
DH+ DH-485 Coated Certified
ControlNet (1)
2711P-RN6 • •
2711P-RN6K • • •
2711P-RN15S • •
2711P-RN15SK • •
(1) Scheduled and unscheduled communication.

Table 9 - Secure Digital (SD) Cards


Cat. No. Description
1784-SD1 1 GB Secure Digital (SD) card
1784-SD2 2 GB Secure Digital (SD) card
2711C-RCSD USB to SD adapter for secure Digital card (SD)

Table 10 - Function Key Legend Inserts


PanelView Plus 6
Cat. No. Includes
Terminal Model(1)
2711P-RFK7 700 keypad
2711P-RFK10 1000 keypad Blank legend inserts
2711P-RFK12 1250 keypad and software

22711P-RFK15 1500 keypad


(1) Applies to keypad and keypad/touch-screen terminals.

Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010


PanelView Plus Specifications 9

Table 11 - Antiglare Overlays

PanelView Plus 6 Operator Input


Cat. No.(1) Terminal Model Keypad Touch Key/Touch
2711P-RGK7 • •
700
2711P-RGT7 •
2711P-RGK10 • •
1000
2711P-RGT10 •
2711P-RGK12 • •
1250
2711P-RGT12 •
2711P-RGK15 • •
1500
2711P-RGT15 •
(1) Three overlays are shipped with each catalog number.

Table 12 - Solar Visor


Cat. No. Description
2711P-RVT12 Solar visor for 1250 high-bright display module, cat. no. 2711P-RDT12H

Table 13 - Mounting Hardware


Cat. No. Description Quantity
2711P-RTMC Mounting clips 8

Table 14 - Battery Replacement


Cat. No. Description Quantity
2711P-RY2032 Replacement battery 1

Table 15 - Power Supply and Power Terminal Blocks


Cat. No. Description Quantity
2711P-RSACDIN DIN-rail power supply, AC-to-DC, 85…265V AC, 47…63 Hz 1
2711P-RTBAC3 AC power terminal block 10
2711P-RTBDC2 2-pin DC power terminal block 10

Table 16 - Programming Cable


Cat. No. Description Length
2711C-CBL-UU02 USB host to USB device programming cable 2 m (6.5 ft)

Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010


10 PanelView Plus Specifications

Table 17 - Backlight Replacements


PanelView Plus 6 Number of
Cat. No. Series
Display Module Size Backlights
2711P-RL7C 700 A and B 1
2711P-RL7C2 C and D 1
2711P-RL10C 1000 A 1
2711P-RL10C2 B and C 1
2711P-RL12C 1250 A and B 2
2711P-RL12C2 C 1
2711P-RL15C 1500 B 2

Table 18 - Bezel Replacements

PanelView Plus 6 Operator Input


Cat. No. Terminal Model Keypad Touch Key/Touch
2711P-RBK7 •
2711P-RBT7 700 •
2711P-RBB7 •
2711P-RBK10 •
2711P-RBT10 1000 •
2711P-RBB10 •
2711P-RBK12 •
2711P-RBT12 •
1250
2711P-RBT12H(1) •
2711P-RBB12 •
2711P-RBK15 •
2711P-RBT15 1500 •
2711P-RBB15 •
(1) Applies to the cat. no. 2711P-RDT12H 1250 high-bright display module.

Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010


PanelView Plus Specifications 11

PanelView Plus 400 and 600 The PanelView Plus 400 and 600 terminals combine a 3.5 or 5.5-in. display, logic
module, memory, and power (AC or DC) in the base unit. The terminals offer a
Terminals range of display and input options:
• PanelView Plus 400 grayscale graphic displays with keypad input
• PanelView Plus 400 color graphic displays with keypad or combination
keypad/touch-screen input
• PanelView Plus 600 color or grayscale graphic displays with keypad, touch
screen, or combination keypad/touch-screen input

Two base units are available.

Table 19 - Base-configured Terminals


Base Unit Contains
RS-232 unit This base unit contains the following:
• RS-232 communication port
• USB port connects to mouse, keyboard, printer, bar code
scanner and other devices.
• CompactFlash slot for file transfers and data logging
For applications with limited budgets that require only PLC
communication, the RS-232 port of this unit supports DF1,
DH-485, and other multivendor PLC protocols.
Ethernet and RS-232 unit This base unit contains the following:
• Ethernet port
• RS-232 communication port
• USB port connects to mouse, keyboard, printer, bar code
scanner and other devices.
• CompactFlash slot for file transfers and data logging.
• Network interface for optional communication modules
including DH-485, DH+, ControlNet, and isolated RS-232
For distributed and complex applications requiring PLC
communication, this unit can provide simultaneous
communication with multiple networks.

Other features include the following:


• Unique mounting mechanism requiring a single die-cut and no special
tools for installation
• Replaceable bezel ID labels for terminal or system identification
• Function key legend kit and software for customizing the function key
legends of PanelView Plus 600 keypad terminals
• Same panel cutouts as the PanelView Standard 550 terminals

Each terminal is preloaded with FactoryTalk View Machine Edition that does not
require activation. Applications are created using FactoryTalk View Studio for
Machine Edition software.

For a complete listing of catalog number selections, refer to the Visualization


Solutions Selection Guide, publication VIEW-SG001.

Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010


12 PanelView Plus Specifications

Technical Specifications - PanelView Plus 400 and 600 Terminals

Table 20 - Technical Specifications - PanelView Plus 400 and 600 Terminals


400 Grayscale 400 Color 600 Grayscale 600 Color
Attribute
2711P-K4M 2711P-K4C, -B4C 2711P-K6M, -T6M, -B6M 2711P-K6C, -T6C, -B6C
Operator input Keypad Keypad or Keypad/Touch Keypad, Touch, or Key/Touch Keypad, Touch, or Key/Touch
Display type Grayscale passive-matrix Color active-matrix TFT Grayscale passive-matrix Color active-matrix TFT
FSTN FSTN
Display size 3.8 in. 3.5 in. 5.5 in.
Display area (WxH) 78 x 59 mm (3.07 x 2.32 in.) 71 x 53 mm (2.8 x 2.1 in.) 111 x 84 mm (4.37 x 3.30 in.)
Resolution 320 x 240, 32-level gray 320 x 240 320 x 240, 32-level gray 320 x 240
18-bit color graphics 18-bit color graphics
Luminance 120 cd/m2 Nits 200 cd/m2 Nits 300 cd/m2 Nits 300 cd/m2 Nits
Backlight LED CCFL 50,000 h life, min.; not replaceable
Touch screen — Analog resistive Analog resistive
Actuation: 1 million presses Actuation: 1 million presses
Operating force: 10…110 g Operating force: 10…110 g
Keypad description Poly-domed membrane Stainless-steel membrane
Numeric, navigation, and function keys Numeric, navigation, and function keys
Actuation: 1 million presses; operating force: 340 g Actuation: 1 million presses; operating force: 340 g
Keypad function keys 8 function keys (F1…F8) 10 function keys (F1…F10)
Real-time clock Battery-backed clock timestamps critical data, ±2 minutes per month
Battery Not replaceable - Battery life: 5 year min. @ 25 °C (77 °F)
Memory 64 MB nonvolatile flash/64 MB RAM for bitmaps or recording data (not expandable); 20 MB for application storage
External storage 256 MB (cat. no. 2711P-RC3) or 512 MB (cat. no. 2711P-RC4) CompactFlash card
Software FactoryTalk View Studio for Machine Edition or Enterprise Series
Communication ports RS-232 and 1 USB or
Ethernet, RS-232, and 1 USB plus optional DH-485, DH+, ControlNet(1), or Isolated RS-232 communication module
Input voltage, DC 18…30V DC (24V DC nom)
Power consumption, DC 25 W max (1.0 A at 24V DC)
External power supply Cat. no. 2711P-RSACDIN, Class 2 or Safety Extra-Low Voltage (SELV) isolated power supply for non-isolated
400 and 600 DC powered terminals; 85…264V AC, 120VA max
Input voltage, AC 85…264V AC, 47…63 Hz
Power consumption, AC 60VA max
Weight, approx. Keypad: 562 g (1.24 lb) Keypad: 562 g (1.24 lb) Keypad: 930 g (2.05 lb)
Touch: — Touch: — Touch: 789 g (1.74 lb)
Dimensions (HxWxD), approx. Keypad: 152 x 185 x 90 mm Keypad: 152 x 185 x 90 mm Keypad: 167 x 266 x 98 mm
6.0 x 7.28 x 3.54 in. 6.0 x 7.28 x 3.54 in. 6.58 x 10.47 x 3.86 in.
Touch: — Touch: 152 x 185 x 90 mm Touch: 152 x 185 x 98 mm
6.0 x 7.28 x 3.54 in. 6.0 x 7.28 x 3.86 in.
Cutout dimensions (HxWxD) Keypad: 123 x 156 mm Keypad: 123 x 156 mm Keypad: 142 x 241 mm
4.86 x 6.15 in. 4.86 x 6.15 in. 5.61 x 9.50 in.
Touch: — Touch: 123 x 156 mm Touch: 123 x 156 mm
4.86 x 6.15 in. 4.86 x 6.15 in.

(1) ControlNet network requires FactoryTalk View Machine Edition software, version 4.0 or later.

Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010


PanelView Plus Specifications 13

Terminal Dimensions - PanelView Plus 400 and 600 Terminals


The table provides overall dimensions and cutout dimensions for the
PanelView 400 and 600 terminals. The 600 touch, and keypad and touch
terminal are shown for reference.

600 Keypad Shown

a
b

600 Touch Shown

a
b

Table 21 - PanelView Plus 400 and 600 Terminal Dimensions


Terminal Type Width Height Depth a Depth b Cutout Width Cutout Height
400 Keypad 185 mm 152 mm 60 mm 90 mm 156 mm 123 mm
7.28 in. 6.00 in. 2.35 in. 3.54 in. 6.15 in. 4.86 in.
600 Keypad and Touch 266 mm 167 mm 68 mm 98 mm 241 mm 142 mm
10.57 in. 6.58 in. 2.68 in. 3.86 in. 9.50 in. 5.61 in.
600 Touch 185 mm 152 mm 68 mm 98 mm 156 mm 123 mm
7.28 in. 6.00 in. 2.68 in. 3.86 in. 6.15 in. 4.86 in.

Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010


14 PanelView Plus Specifications

Accessories - PanelView Plus 400 and 600 Terminals


Tables 22…27 lists accessories for the PanelView Plus 400 and 600 terminals.
Table 22 - Communication Modules
Communication
Cat. No.
DH+ DH-485 ControlNet(1) RS-232 Isolated
2711P-RN3 •
2711P-RN8 •
2711P-RN15C •
2711P-RN22C •
(1) Scheduled and unscheduled communication.

Table 23 - Antiglare Overlays


Input Type
Cat. No.(1) Terminal Model
Keypad Touch Key/Touch
2711P-RGK4 400 Grayscale •
2711P-RGB4 400 Color • •
2711P-RGK6 • •
600 Grayscale or Color
2711P-RGT6 •
(1) Three overlays are shipped with each catalog number.

Table 24 - CompactFlash Cards


Cat. No. Description
2711P-RC3 256 MB blank CompactFlash card
2711P-RC4 512 MB blank CompactFlash card
2711P-RCH CompactFlash to PCMCIA adapter

Table 25 - Power Terminal Blocks


Cat. No. Description Quantity
2711P-RVAC AC power terminal block 10
2711-TBDC DC power terminal block 10

Table 26 - Mounting Hardware


Cat. No. Description Quantity
2711P-RTFC Mounting levers 8

Table 27 - Function Key Legend Inserts


Cat. No. Terminal Model Includes
2711P-RFK6 600 keypad and keypad/touch Blank legend inserts and software

Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010


PanelView Plus Specifications 15

PanelView Plus Compact The PanelView Plus Compact 400, 600, and 1000 terminals provide a solution
for midsize applications requiring fewer displays and alarms in a FactoryTalk
Terminals View ME application. These terminals are a subset of the PanelView Plus family
with selective hardware and software functionality. They are the preferred HMI
solution for many of the CompactLogix controllers.

These are the major features of the PanelView Plus Compact terminals:
• Preferred HMI for CompactLogix controllers
• RS-232 serial port, Ethernet port, USB port (two on 1000 model), DC
power input, and CompactFlash Type 1 slot
• Serial and Ethernet communication only
• Connection to a single controller by using either RSLinx Enterprise
software, version 5.20 or later, or KEPServer software
• 25 displays and 200 alarm messages supported in the FactoryTalk View
Compact Machine Edition application and runtime software
• Fixed hardware configurations without the addition or replacement of
modular components

For a complete listing of catalog number selections, refer to the Visualization


Solutions Selection Guide, publication VIEW-SG001.

Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010


16 PanelView Plus Specifications

Technical Specifications - PanelView Plus Compact Terminals

Table 28 - Technical Specifications - PanelView Plus Compact Terminals


400 Grayscale 400 Color 600 Grayscale 600 Color 1000 Color
Attribute
2711PC-K4M20D 2711PC-B4C20D 2711PC-T6M20D 2711PC-T6C20D 2711PC-T10C4D1
Operator input Keypad Keypad/Touch Touch Touch Touch
Display type Passive-matrix FSTN Active-matrix TFT Passive-matrix FSTN Active-matrix TFT Active-matrix TFT
Display size 3.8 in. 3.5 in. 5.5 in. 10.4 in.
Display area (WxH) 78 x 59 mm (3.07 x 2.32 in.) 71 x 53 mm (2.8 x 2.1 in.) 111 x 84 mm (4.37 x 3.30 in.) 211 x 158 mm (8.3 x 6.2 in.)
Resolution 320 x 240, 32-level gray 320 x 240, 18-bit color 320 x 240, 32-level gray 320 x 240, 18-bit color 640 x 480, 18-bit color
2 Nits
Luminance 120 cd/m 200 cd/m2 Nits 300 cd/m2 Nits 300 cd/m2 Nits
Backlight LED CCFL 50,000 h life, min. CCFL 50,000 h life, min.,
Not replaceable field replaceable
Touch screen — Analog resistive; actuation 1 million presses; operating force 10…110 g

Keypad description Poly-domed membrane Stainless-steel membrane


Numeric, navigation, and function keys Numeric, navigation, and function keys
Actuation: 1 million presses; operating force: 340 g Actuation: 1 million presses; operating force: 340 g
Keypad function keys 8 function keys (F1…F8) — — —
Real-time clock Battery-backed clock timestamps critical data, ±2 minutes per month

Battery 5 year min. @ 25 °C (77 °F); 4 year min. @ 25 °C (77 °F)


Not replaceable Replacement:
2711P-RY2032
Memory 64 MB nonvolatile flash/64 MB RAM, non-expandable 64 MB nonvolatile flash/64
20 MB for application storage MB RAM, non-expandable;
25 MB for application storage
External storage 256 MB (cat. no. 2711P-RC3) or 512 MB (cat. no. 2711P-RC4) CompactFlash card
Software FactoryTalk View Studio for Machine Edition, version 5.1

Communication ports RS-232, Ethernet, 1 USB; no communication interface RS-232, Ethernet, 2 USB; no
communication interface
Input voltage, DC 18…30V DC (24V DC nom) 18…32V DC (24V DC nom)

Power consumption, DC 25 W max (1.0 A at 24V DC) 70 W max (2.9 A at 24V DC)

External power supply Cat. no. 2711P-RSACDIN, Class 2 or Safety Extra-Low Voltage (SELV) isolated power supply for DC powered terminals; 85…264V AC,
120VA max
Weight, approx. 562 g (1.24 lb) 562 g (1.24 lb) 789 g (1.74 lb) 2.6 kg (5.7 lb)

Dimensions (HxWxD), 152 x 185 x 90 mm 152 x 185 x 90 mm 152 x 185 x 98 mm 248 x 329 x 55 mm
approx. 6.0 x 7.28 x 3.54 in. 6.0 x 7.28 x 3.54 in. 6.0 x 7.28 x 3.86 in. 9.77 x 12.97 x 2.18 in.

Cutout dimensions 123 x 156 mm 123 x 156 mm 123 x 156 mm 224 x 305 mm
(HxWxD) 4.86 x 6.15 in. 4.86 x 6.15 in. 4.86 x 6.15 in. 8.8 x 12.0 in.

Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010


PanelView Plus Specifications 17

Accessories - PanelView Plus Compact Terminals


Tables 29…34 lists accessories for the PanelView Plus Compact terminals.
Table 29 - Antiglare Overlays
Operator Input
Cat. No.(1) Terminal Model
Keypad Touch Key/Touch
2711P-RGK4 400 grayscale •
2711P-RGB4 400 color • •
2711P-RGT6 600 color grayscale •
2711P-RGT10 1000 color •
(1) Three overlays are shipped with each catalog number.

Table 30 - CompactFlash Cards


Cat. No. Description
2711P-RC3 256 MB blank CompactFlash card
2711P-RC4 512 MB blank CompactFlash card
2711P-RCH CompactFlash to PCMCIA Adapter

Table 31 - Backlight Replacement


Cat. No. Description
2711P-RL10C2 Color backlight replacement for the 1000 series B and C displays

Table 32 - Bezel Replacements


Cat. No. Description
2711P-RBT10 Replacement bezel for the 1000 touch terminal

Table 33 - Mounting Hardware


Cat. No. Terminal Model Description Quantity
2711P-RTFC 400 and 600 Mounting levers 8
2711P-RTMC 1000 Mounting clips 8

Table 34 - Power Terminal Blocks


Cat. No. Terminal Model Description Quantity
2711-TBDC 400 and 600 DC power terminal block 10
2711P-RTBDC2 700 to 1500 2-pin DC power terminal block 10
series E or later

Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010


18 PanelView Plus Specifications

External Power Supply This SELV or PELV, 24V DC power supply can be used to power any of the
PanelView Plus terminals with a DC power input. This power supply provides
protection so that under normal and single fault conditions, the voltage
between conductors and earth ground does not exceed a safe value.
Table 35 - Environmental Specifications - 2711P-RSACDIN Power Supply
Attribute 2711P-RSACDIN

Temperature, operating 0…55 °C (32…131 °F)


IEC 60068-2-1 (Test Ad, Operating Cold)
IEC 60068-2-2 (Test Bd, Operating Dry Heat)
IEC 60068-2-14 (Test Nb, Operating Thermal Shock)
Temperature, storage -40…85 °C (-40…185 °F)
IEC 60068-2-1 (Test Ab, Unpackaged, Nonoperating Cold)
IEC 60068-2-2 (Test Bb, Unpackaged, Nonoperating Dry Heat)
IEC 60068-2-14 (Test Nb, Unpackaged, Nonoperating Thermal Shock)
Relative humidity 5...95% noncondensing
IEC 60068-2-30 (Test Db, Unpackaged, Nonoperating Damp Heat)
Vibration 5 g at 10…500 Hz
IEC 60068-2-6 (Test Fc, Operating)
Shock, operating 15 g
IEC 60068-2-27 (Test Ea, Unpackaged Shock)
Shock, nonoperating 30 g
IEC 60068-2-27 (Test Ea, Unpackaged Shock)
ESD immunity 4 kV contact discharges
IEC 61000-4-2 8 kV air discharges
Radiated RF immunity 10V/m with 1 kHz sine-wave 80% AM from 30…1000 MHz
IEC 61000-4-3
EFT/B immunity ±2 kV at 5 kHz on power ports
IEC 61000-4-4
Surge transient immunity ±1 kV line-line (DM) and ±2 kV line-earth (CM) on AC power ports
IEC 61000-4-5
Conducted RF immunity 10V rms with 1kHz sine wave 80% AM from 150 kHz…80 MHz
IEC 61000-4-6
Enclosure type rating None (open-style)
Power conductors
Wire Size 12 gauge (4 mm2 ) max solid or stranded copper wire rated
at 75 °C (167 °F) or greater
1.2 mm ((3/64 in.) insulation max
Category 1 (1)

(1) Use this conductor capacity information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1.

Table 36 - Certifications - 2711P-RSACDIN Power Supply

Certification(1) 2711P-RSACDIN

c-UL-us UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E10314.
UL Listed for Class, Division 2 Groups A, B, C, and D for US and Canada.
CE European Union 89/336/EEC EMC Directive, compliant with:
• EN 61000-6-2; Industrial Immunity
• EN 61326, Meas./Control/Lab., Industrial Requirements
• EN 61000-6-4; Industrial Emissions
European Union 73235/EEC Low Voltage Directive, compliant with:
• EN 61131-2; Programmable Controllers
C-Tick Australian Radiocommunications Act, compliant with:
AS/NZS 2064, Industrial Emissions

(1) When marked. See the Product Certification link at http://www.ab.com for Declarations of Conformity,
Certificates, and other certification details.

Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010


PanelView Plus Specifications 19

Table 37 - Technical Specifications - 2711P-RSACDIN Power Supply


Attribute 2711P-RSACDIN

Input Specifications
Supply voltage, nom 120V AC, 47…63 Hz, 1.7 A max
230V AC, 47…63 Hz, 1.1 A max
Voltage range 85…265V AC
Inrush current 40 A typical, 1 AC cycle at Vin 265V AC, 55 °C (131 °F)
Interruption Output voltage will stay within specification when input drops out for 1/2
cycle at 47 Hz, 85V AC with max load
Output Specifications
Output voltage, nom +24V DC SELV
Voltage range 20.4…27.6V DC, includes noise and 5% AC ripple
Inrush current 40 A typical, 1 AC cycle at Vin 265V AC, 55 °C (131 °F)
Minimum load 50 mA
Overvoltage protection Output internally limited to 35V DC. Cycle power to re-energize.
Overcurrent protection Current limit 3.2 A min (107% min)
Leakage current 0.5 mA rms max at rated input and output
Isolation voltage 2830V DC for 1 second

Table 38 - Dimensions - 2711P-RSACDIN Power Supply


Attribute 2711P-RSACDIN

Mounting Horizontal on a DIN rail


Wall or panel mount with cat. no. 1794-NM1 panel mounting kit
Terminal screw torque 0.5…0.6 N•m (5…7 lb•in)
Dimensions (HxWxD), approx. 87 x 68 x 69 mm (3.4 x 2.7 x 2.7 in.)

Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010


20 PanelView Plus Specifications

HMI Software All PanelView Plus terminals are configured with FactoryTalk View Studio
software and have an integrated runtime system called FactoryTalk View
Machine Edition Station.

Machine Edition Station runs projects developed with FactoryTalk View Studio.
Two versions of FactoryTalk View Studio support application development for
PanelView Plus terminals.
Table 39 - HMI Software for PanelView Plus Terminals
Cat. No, Description
9701-VWSTMENE FactoryTalk View Studio for Machine Edition - Configuration software for
developing and testing machine level human machine interface (HMI)
applications.
9701-VWSTENE FactoryTalk View Studio - Configuration software for developing and
testing machine level and supervisory level human machine interface
(HMI) applications.

You can import PanelView Standard/PanelBuilder32 and PanelView e


applications into FactoryTalk View Studio as Machine Edition applications using
the Machine Edition Import Wizard. The Import Wizard steps you through a
few options such as scaling to a new screen resolution size, and then converts
objects, text, tags, and communication configurations to ones that are available in
Machine Edition.

FactoryTalk ViewPoint software, an add-on to FactoryTalk View Studio software,


allows plant managers, production supervisors, system integrators, and other key
stakeholders to view real-time plant floor operations remotely from a web
browser. FactoryTalk ViewPoint enabled displays are fully scalable and animated
in the browser. The remote user can also view displays that are not the active
display of the terminal.

Each PanelView Plus 6 terminal contains one license supporting a single client
connection to the terminal. No additional software is required.

For a complete list of available HMI software, visit


http://www.rockwellautomation.com/rockwellsoftware.

Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010


PanelView Plus Specifications 21

Software Comparison
TECHNOLOGY: Customer Requirements FactoryTalk View Site Edition FactoryTalk View Machine Edition RSView32
Operating systems (32-bit) • Windows XP • Windows XP • Windows XP/2000/NT/9x/
• Windows Server 2003 • Windows 7 Professional • Windows Server 2003
• Windows Vista Business • Windows CE
• Windows Server 2008 • Windows Vista Home Basic/Vista Business
• Windows Server 2003/2008
Embedded platforms ✔
Windows domain security ✔ ✔ ✔
OPC/ActiveX ✔ ✔ ✔
FactoryTalk enabled ✔ ✔ ✔
Server-side VBA ✔
Client-side VBA ✔

ARCHITECTURE: Customer Requirements FactoryTalk View Site Edition FactoryTalk View Machine Edition RSView32
Primary application Supervisory level: single-station or Machine level: single-station Supervisory level; single station or single
multiple-server, multiple-client server, multiple client
Tag-based HMI ✔ ✔ • Windows XP/2000/NT/9x/
• Windows Server 2003
Direct referencing ✔ ✔
Network (Distributed) Local
Max number of servers/clients 10/50 1/20
FactoryTalk ViewPoint ✔ ✔ (1) ✔

RSView32 web server ✔
Thin clients (terminal services) ✔ ✔
Multi-user development ✔
Remote configuration at runtime ✔
Redundancy - data server ✔
Redundancy - HMI server ✔ Active display

(1) Supported only on PanelView Plus terminals.

FEATURES: Customer Requirements FactoryTalk View Site Edition FactoryTalk View Machine Edition RSView32
Animation - visibility, color, fill, horizontal and And touch And touch And touch
vertical position, width, height, rotation,
horizontal and vertical slider, and more
Alarms • Tag-based and device-based • State-based (from controller) • Tag-based
• Digital and analog • Alarm log • Digital and analog
• Definable alarm severities • Definable alarm severities
• Alarm log • Alarm log
Data logging • 20 data log models per project • 1 data log model per project • 20 plus data log models per project
• Each with up to 10,000 tags • With up to 100 tags • Each with up to 10,000 tags
• Log to ODBC or proprietary database • 300K records max • Log to ODBC or proprietary database
• Export to dbf
Trending TrendX 4.0 TrendX 4.0 subset TrendX 3.1 and native
Security • Security assigned to tags, graphic displays, • Display-based • Security assigned to tags, graphic displays,
macros, commands, OLE objects • Local or Windows security macros, commands, OLE objects
• Local or Windows security • Local or Windows security
Other features • Test run macros • Test run macros • Test run macros
• Derived tags • Derived tags • Derived tags
• Event detector • Event detector
Pricing model • Display-based pricing • Included with PanelView Plus or • Tag-based pricing
• Multiple levels display-based pricing • Multiple levels
• Multiple levels for FactoryTalk View ME
Station

Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010


22 PanelView Plus Specifications

Software Selection
FactoryTalk View Studio for Machine Edition software is configuration
software for developing and testing machine level HMI applications. It
includes RSLinx Enterprise and KEPServer Enterprise.
Table 40 - FactoryTalk View Machine Edition (ME) Software
Cat. No.(1) Description
9701-VWSTMENE FactoryTalk View Studio Machine Edition
(1) Order localized versions of the software by replacing EN in the catalog number with DE for German, FR for
French, JP for Japanese, or ZH for Chinese.

FactoryTalk View Machine Edition Station is the runtime environment used to


run FactoryTalk View ME projects created with FactoryTalk View Studio
software on any computer with the Windows 7 Professional, XP/Vista Home
Basic/Vista Business/Windows Server 2003/2008 operating system including
the industrial computers. FactoryTalk View ME Station is included with all
PanelView Plus terminals.
Table 41 - FactoryTalk View Machine Edition (ME) Station Runtime
Cat. No.(1) Description
9701-VWMR015AENE FactoryTalk View ME Station runtime 15 displays
9701-VWMR030AENE FactoryTalk View ME Station runtime 30 displays
9701-VWMR075AENE FactoryTalk View ME Station runtime 75 displays
9701-VWMR250AENE FactoryTalk View ME Station runtime 250 displays RS-232 operating
cable, 9-pin D Shell to 8-pin Mini DIN
(1) Order localized versions of the software by replacing EN in the catalog number with DE for German, FR for
French, JP for Japanese, or ZH for Chinese.

FactoryTalk ViewPoint software is an add-on to FactoryTalk View Studio


software, allowing casual users to view real-time plant floor operations
remotely from a web browser. FactoryTalk ViewPoint server and a single client
access license is included with the purchase of a PanelView Plus terminal. No
other catalog numbers are required to use FactoryTalk ViewPoint software
with PanelView Plus terminals.
Table 42 - FactoryTalk ViewPoint Software
Cat. No.(1) Description
9552-VWP01RENE FactoryTalk ViewPoint 1 client system (read only)
9552-VWP03RENE FactoryTalk ViewPoint 3 client system (read only)
9552-VWP05RENE FactoryTalk ViewPoint 5 client system (read only)
9552-VWP10RENE FactoryTalk ViewPoint 10 client system (read only)
9552-VWP25RENE FactoryTalk ViewPoint 25 client system (read only)
9552-VWP50RENE FactoryTalk ViewPoint 50 client system (read only)
(1) Order any of these catalog numbers to use FactoryTalk ViewPoint software with FactoryTalk View SE network
or local applications.

Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010


PanelView Plus Specifications 23

Communication Cables The table provides a general list of cables used by the PanelView Plus terminals.
All PanelView Plus terminals use a standard Ethernet cable for application
transfers between a computer and the terminal.
Table 43 - Cables
Cat. No. Description Length
2711C-CBL-UU02(1) USB host to USB device programming cable 2 m (6.5 ft)
2711-NC13 RS-232 operating/program cable, 9-pin D-shell to 9-pin D-shell 5 m (16.4 ft)
2711-NC14 RS-232 operating/program cable, 9-pin D-shell to 9-pin D-shell 10 m (32.7 ft)
2711-NC17 Remote RS-232 cable assembly, 9-pin D-shell to 9-pin D-shell 3 m (10 ft)
2711-NC21 RS-232 operating cable, 9-pin D-shell to 8-pin mini DIN 5 m (16.4 ft)
2711-NC22 RS-232 operating cable, 9-pin D-shell to 8-pin mini DIN 15 m (49 ft)
1761-CBL-AS03 3 m (10 ft)
DH-485 network cable, 6-pin Phoenix to RJ45
1761-CBL-AS09 9 m (30 ft)
2711P-CBL-EX04 Ethernet CAT5 crossover cable 4.3 m (14 ft)
(1) This cable is used only by PanelView Plus 6 terminals.

PanelView Plus Runtime Cables


Tables 44…47 list required runtime cables for PanelView Plus 400/600 and
PanelView Plus 6 (700, 1000, 1250, 1500) terminals.

Table 44 - Runtime Communication Cables: PanelView Plus Terminals to SLC Controllers

SLC 500, 5/01, 5/02 SLC 5/03, 5/04, 5/05 SLC 5/03
Protocol PanelView Plus Comm Port CH1 RJ45 CH0 (9-pin RS-232) CH1 (RJ45) SLC 5/04 SLC 5/05
400, 600, 700, 1000, 1250, 1500 CH1 (DH+) CH1 (ENET)
(DH-485) (DF1 or DH-485) (DH-485)
DF1 RS-232 (DF1) port (9-pin)
— 2711-NC13 (5 m/16 ft)
PanelView Plus 400 to 1500
2711-NC14 (10 m/32 ft)
— — —
2711P-RN22C (for 400 and 600 only)

RS-232 (DH-485) port (9-pin) Use AIC+ module Use AIC+ Module
2711-NC13 (5 m/16 ft)
PanelView Plus 400 to 1500 (1761-NET-AIC)
2711-NC14 (10 m/32 ft)
(1761-NET-AIC) — —
2711P-RN22C (for 400 and 600 only) to connect to port 1 or 2 to connect to port 1 or 2

DH-485 port 1747-C10 (2 m/6 ft) Use AIC+ module 1747-C10 (2 m/6 ft)
DH-485
PanelView Plus 400 and 600 1747-C11 (0.3 m/1 ft) (1761-NET-AIC) 1747-C11 (0.3 m/1 ft) — —
Requires 2711P-RN3(1) 1747-C20 (6 m/20 ft) to connect to port 3 1747-C20 (6 m/20 ft)

1761-CBL-AS03 1761-CBL-AS03
DH-485 port Use AIC+ module
(3 m/10 ft) (3 m/10 ft)
PanelView Plus 700 to 1500
1761-CBL-AS09
(1761-NET-AIC)
1761-CBL-AS09
— —
Requires 2711P-RN6, -RN6K to connect to Port 3
(9 m/30 ft) (9 m/30 ft)

ControlNet port
PanelView Plus 400 and 600
ControlNet Requires 2711P-RN15C — — — — —
PanelView Plus 700 to 1500
Requires 2711P-RN15S, -RN15SK

EtherNet/IP port Use 1761-NET-ENI module 1585J-M type cable or


EtherNet/IP
PanelView Plus 400 to 1500
— with Ethernet cable
— — 2711P-CBL-EX04
(4 m/14 ft) (2)

DH+ DH+ port


shielded
PanelView Plus 400 and 600 — —
twinaxial
Requires 2711P-RN8 — —
PanelView Plus 700 to 1500 cable
(1770-CD)
Requires 2711P-RN6, -RN6K

(1) For CE compliance, use the 1761-NET-AIC or 1747-AIC module for cable lengths longer than 30 m (98 ft).
(2) EtherNet/IP direct connection from the terminal to an SLC 5/05 controller requires an Ethernet switch or the 2711P-CBL-EX04 crossover cable.

Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010


24 PanelView Plus Specifications

Table 45 - Runtime Communication Cables: PanelView Plus Terminals to PLC-5 and MicroLogix Controllers
MicroLogix 1000, 1100, 1200,
PLC-5, PLC-5C, PLC-5E MicroLogix 1400, 1500LRP
PanelView Plus Comm Port 1400, 1500LSP MicroLogix 1100, 1400
Protocol 400, 600, 700, 1000, 1250, 1500
CH0 (25-pin RS-232) CH1/CH2 (9-pin RS-232)
CH0 (8-pin Mini DIN) Ethernet
(DF1) (DF1 or DH-485)
(DF1 or DH-485)
DF1 RS-232 (DF1) port (9-pin) 2711-NC13 (5 m/16 ft)
2711-NC13 (5 m/16 ft) 2711-NC21 (5 m/16 ft) —
PanelView Plus 400 to 1500 2711-NC14 (10 m/32 ft)
2711-NC14 (10 m/32 ft) 2711-NC22 (15 m/49 ft) (3)
2711P-RN22C (for 400 and 600 only) (9-to-25 pin adapter required)
RS-232 (DH-485) port (9-pin)
— 2711-NC13 (5 m/16 ft) 2711-NC21 (5 m/16 ft) —
PanelView Plus 400 to 1500
2711-NC14 (10 m/32 ft) 2711-NC22 (15 m/49 ft)
2711P-RN22C (for 400 and 600 only)
DH-485 DH-485 port Use AIC+ module
PanelView Plus 400 and 600 — — (1761-NET-AIC) —
Requires 2711P-RN3(1) to connect to Port 3
PanelView Plus 700 to 1500
Requires 2711P-RN6, -RN6K
ControlNet port
PanelView Plus 400 and 600
Requires 2711P-RN15C To PLC-5C with — — —
ControlNet
PanelView Plus 400 to 1500 ControlNet cable
Requires 2711P-RN15S, -RN15SK
To PLC-5E with
EtherNet/IP port Use 1761-NET-ENI module 1585J-M type cable or
EtherNet/IP 1585J-M type cable or
PanelView Plus 400 to 1500 with Ethernet cable 2711P- CBL-EX04 (4 m/14 ft) (2)
2711P- CBL-EX04 (4 m/14 ft) (2)
DH+ DH+ port
PanelView Plus 400 and 600 shielded twinaxial cable — — —
Requires 2711P-RN8
PanelView Plus 700 to 1500 (1770-CD)
Requires 2711P-RN6, -RN6K

(1) For CE compliance, use the 1761-NET-AIC or 1747-AIC module for cable lengths longer than 30 m (98 ft).
(2) For a direct connection between the terminal and the controller use the 2711P-CBL-EX04 crossover cable.
(3) The AIC+ module is recommended for isolation purposes when the terminal and controller are not on same power supply.

Table 46 - Runtime Communication Cables: PanelView Plus Terminals to Logix Controllers


ControlLogix CompactLogix
Protocol PanelView Plus Comm Port CH0 (9-pin RS-232) CH0 (9-pin RS-232)
400, 600, 700, 1000, 1250, 1500 (DF1) (DF1 or DH-485)

DF1 RS-232 (DF1) port (9-pin) 2711-NC13 (5 m/16 ft)


PanelView Plus 400 to 1500 2711-NC14 (10 m/32 ft)
2711P-RN22C (for 400 and 600 only) 2706-NC13 (3 m/10 ft)

RS-232 (DH-485) port (9-pin) 2711-NC13 (5 m/16 ft)



PanelView Plus 400 to 1500 2711-NC14 (10 m/32 ft)
2711P-RN22C (for 400 and 600 only) 2706-NC13 (3 m/10 ft)
DH-485
DH-485 port Use AIC+ module
PanelView Plus 400 and 600 requires 2711P-RN3(1) — (1761-NET-AIC)
PanelView Plus 700 to 1500 requires 2711P-RN6, -RN6K to connect to port 3

ControlNet port
1769-L35CR, 1769-L32C, 1768-CNB, or 1768-CNBR
ControlNet PanelView Plus 400 and 600 requires 2711P-RN15C Use 1756-CNB module with ControlNet cable
with ControlNet cable
PanelView Plus 700 to 1500 requires 2711P-RN15S, -RN15SK

Use 1756-EN2T or 1756-ENBT module with To 1769-L35E, 1769-L23E, 1769-L32E,


EtherNet/IP port
EtherNet/IP 1585J-M type cable or or 1768-ENBT module with 1585J-M type cable
PanelView Plus 400 to 1500 2711P- CBL-EX04 (4 m/14 ft)(2) or 2711P- CBL-EX04 (4 m/14 ft)(2)

DH+ DH+ port


Use 1756-DHRIO module with
PanelView Plus 400 and 600 requires 2711P-RN8
shielded twinaxial cable (1770-CD)

PanelView Plus 700 to 1500 requires 2711P-RN6, -RN6K

(1) For CE compliance, use the 1761-NET-AIC or 1747-AIC module for cable lengths longer than 30 m (98 ft).
(2) For a direct connection between the terminal and controller, use the 2711P-CBL-EX04 crossover cable.

Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010


PanelView Plus Specifications 25

Table 47 - Runtime Communication Cables: PanelView Plus Terminals to Interface Modules


1761-NET-AIC 1771-NET-ENI
PanelView Plus Comm Port
Protocol 400, 600, 700, 1000, 1250, 1500 1747-AIC
Port 2 Port 3 Port 2
Port 1 (9-pin) (8-pin Mini DIN) (DH-485) (8-pin Mini DIN)

DF1 RS-232 port (9-pin) 1761-CBL-AP00 (5 m)


PanelView Plus 400 to 1500 — 2711-NC21 (5 m/16 ft)
2711-NC13 (5 m/16 ft) 1761-CBL-PM02 (2 m)
2711P-RN22C (for 400 and 600) 2711-NC14 (10 m/32 ft) 2711-NC22 (15 m/49 ft) — 2711-CBL-PM05 (5 m)
Null modem required
2711-CBL-PM10 (10 m)

RS-232 port (9-pin) 2711-NC21 (5 m/16 ft)


2711-NC13 (5 m/16 ft)
PanelView Plus 400 to 1500 — 2711-NC14 (10 m/32 ft)
2711-NC22 (15 m/49 ft) —
2711P-RN22C (for 400 and 600) Null modem required

DH-485 port 1747-C10 (2 m/6ft) 1761-CBL-AS03 (3 m/10 ft)


— — —
DH-485 PanelView Plus 400 and 600 1747-C11 (0.3 m/1 ft) 1761-CBL-AS09 (9 m/30 ft)
Requires 2711P-RN3(1) 1747-C20 (6 m/20 ft) to single AIC+

DH-485 port Direct connection to Direct connection to


PanelView Plus 700 to 1500 single AIC with — — single AIC+ with —
Requires 2711P-RN6, -RN6K Belden 9842 cable(2) Belden 9842 cable(2)

(1) For CE compliance, use the 1761-NET-AIC or 1747-AIC module for cable lengths longer than 30 m (98 ft).
(2) Use serial port on the PanelView Plus terminal with an AIC+ module for a DH-485 network solution.

PanelView Plus Compact Runtime Cables

Tables 48…51 list cables required to connect PanelView Plus Compact terminals
to controllers and interface modules for runtime operations.

Table 48 - Runtime Communication Cables: PanelView Plus Compact Terminals to SLC Controllers
SLC-500, 5/01, 5/02 SLC-5/03, 5/04, 5/05 SLC 5/03
PanelView Plus Compact SLC 5/04 SLC 5/05
Protocol 400, 600, 1000 Comm Port
CH1 RJ45 CH0 (9-pin RS-232) CH1 (RJ45)
CH1 (DH+) CH1 (ENET)
(DH-485) (DF1 or DH-485) (DH-485)

2711-NC13 (5 m/16 ft) — —


DF1 RS-232 (DF1) Comm port (9-pin) — 2711-NC14 (10 m/32 ft)

Use AIC+ module Use AIC+ module


2711-NC13 (5 m/16 ft)
DH-485 RS-232 (DH-485) Comm port (9-pin) (1761-NET-AIC)
2711-NC14 (10 m/32 ft)
(1761-NET-AIC) — —
to connect to port 1 or 2 to connect to port 1 or 2

Use 1761-NET-ENI module 2711P- CBL-EX04 Ethernet


EtherNet/IP EtherNet/IP Comm port — with Ethernet cable
— — crossover cable (1)

(1) An EtherNet/IP direction connection between a PanelView Plus Compact terminal and an SLC 5/05 requires hub or crossover cable listed.

Table 49 - Runtime Communication Cables: PanelView Plus Compact Terminals to MicroLogix Controllers

PanelView Plus Compact MicroLogix 1500LRP MicroLogix 1000, 1200, 1500LSP MicroLogix 1100, 1400
Protocol 400, 600, 1000 Comm Port CH1 (9-pin RS-232) CH0 (8-pin Mini DIN) Ethernet Port
(DF1 or DH-485) (DF1 or DH-485)
2711-NC13 (5 m/16 ft) 2711-NC21 (5 m/16 ft)
DF1 RS-232 (DF1) Comm port (9-pin)
2711-NC14 (10 m/32 ft) 2711-NC22 (15 m/49 ft) (1)

2711-NC13 (5 m/16 ft) 2711-NC21 (5 m/16 ft)
DH-485 RS-232 (DH-485) Comm port (9-pin)
2711-NC14 (10 m/32 ft) 2711-NC22 (15 m/49 ft) (1)

Use 1761-NET-ENI module 1585J-M type cable or
EtherNet/IP EtherNet/IP Comm port
with Ethernet cable 2711P-CBL-EX04 cable (4 m/14 ft)(2)

(1) AIC+ Module recommended for isolation when PanelView and controller are not using same power supply.
(2) For a direct connection between the terminal and controller, use the 2711P-CBL-EX04 crossover cable

Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010


26 PanelView Plus Specifications

Table 50 - Runtime Communication Cables: PanelView Plus Compact to Logix Controllers


ControlLogix CompactLogix
PanelView Plus Compact
Protocol 400, 600, 1000 Comm Port
CH0 (9-pin RS-232) CH0 (9-pin RS-232)
(DF1) (DF1 or DH-485)

2711-NC13 (5 m/16 ft)


DF1 RS-232 (DF1) Comm port (9-pin)
2711-NC14 (10 m/32 ft)

2711-NC13 (5 m/16 ft)


DH-485 RS-232 (DH-485) Comm port (9-pin) — 2711-NC14 (10 m/32 ft)

Use 1756-EN2T or 1756-ENBT module To 1769-L35E, L23E, L32E


EtherNet/IP EtherNet/IP Comm port with 1585J-M type cable or with1585J-M type cable or
2711P-CBL-EX04 cable (4 m/14 ft)(1) 2711P-CBL-EX04 cable (4 m/14 ft)(1)

(1) For a direct connection between the terminal and controller, use the 2711P-CBL-EX04 crossover cable.

Table 51 - Runtime Communication Cables: PanelView Plus Compact to Network Modules


1761-NET-AIC
PanelView Plus Compact
Protocol
400, 600, 1000 Comm Port Port 2 Port 3
Port 1 (9-pin) 8-pin Mini DIN (DH-485)

2711-NC13 (5 m/16 ft) 2711-NC21 (5 m/16 ft)


DF1 RS-232 Comm port (9-pin)
2711-NC14 (10 m/32 ft) 2711-NC22 (15 m/49 ft)

2711-NC21 (5 m/16 ft)


2711-NC13 (5 m/16 ft)
DH-485 RS-232 Comm port (9-pin)
2711-NC14 (10 m/32 ft)
2711-NC22 (15 m/49 ft) —

Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010


PanelView Plus Specifications 27

Migration Hardware The PanelView Plus platforms provide a clear migration path for replacing older
terminals. When migrating to a new platform, consider both the display size and
the unit size. PanelView Plus terminals uses the same panel cutouts as existing
PanelView products, yet offer a larger display. For instance, a PanelView Plus 6,
1250 terminal with a 12.1-inch display fits into the same cutout as a PanelView
1000 or 1000e with a 10.4-inch display. When choosing a terminal with the same
display size, adapter plates are used to adapt the cutout of the new terminal.

Table 52 - PanelView Plus Replacement Terminals


Adapter Plate Adapter Plate Cat.
PanelView Standard Terminal PanelView Plus Replacement Terminal Required No.
PanelView Standard 300 or 300 Micro None available(1) — —
PanelView Plus or PanelView Plus Compact 400 keypad or keypad/touch
PanelView 550 or 600 touch No —
PanelView Plus or PanelView Plus Compact 600 touch
PanelView Plus 600 keypad or keypad/touch No —
PanelView 550 keypad
PanelView 550 keypad/touch PanelView Plus PanelView Plus Compact 400 keypad or keypad/touch Yes 2711P-RAK4
PanelView Plus PanelView Plus Compact 600 touch

PanelView 600 keypad PanelView Plus 600 keypad or keypad/touch Yes 2711P-RAK6
PanelView 600 keypad/touch PanelView Plus 6, 700 keypad or keypad/touch No —
PanelView Plus 6, 700 keypad or keypad/touch Yes 2711P-RAK7
PanelView 900 keypad
PanelView Plus 6, 1000 keypad or keypad/touch No —
PanelView Plus 6, 700 touch Yes 2711P-RAT7
PanelView 900 touch
PanelView Plus 6 or PanelView Plus Compact 1000 touch No —
PanelView Plus 6, 1000 keypad or keypad/touch Yes 2711P-RAK10
PanelView 1000 keypad
PanelView Plus 6, 1250 keypad or keypad/touch No —
PanelView Plus 6 or PanelView Plus Compact 1000 touch Yes 2711P-RAT10
PanelView 1000 touch
PanelView Plus 6, 1250 touch No —
PanelView Plus 6, 1250 keypad or keypad/touch Yes 2711P-RAK12S
PanelView 1400 keypad
PanelView Plus 6, 1500 keypad or keypad/touch No —
(2)
PanelView Plus 6, 1500 keypad or keypad/touch Yes 2711P-RAK15
PanelView1400e keypad
None available — —
PanelView 1400 touch PanelView Plus 6, 1250 touch Yes 2711P-RAT12S
PanelView Plus 6, 1500 touch No —
(2)
PanelView Plus 6,1500 touch Yes 2711P-RAT15
PanelView 1400e touch
None available — —
(2)
PanelView 1200, 1200e/1400e Keypad PanelView Plus 6,1250 keypad Yes RAK12E
None available — —
(3)
PanelView 1200, 1200e Touch PanelView Plus 6,1250 touch Yes RAT12E
None available — —
(3)
PanelView 1200/1200E touch PanelView Plus 6,1250 touch Yes 2711P-RAT12E2
None available — —

(1) Replace the PanelView Standard 300 or 300 Micro with a PanelView Plus 400 keypad terminal by increasing the size of the current panel cutout.
(2) Adapter plate required for stud-mounted terminals.
(3) Requires modification of panel cutout.

Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010


28 PanelView Plus Specifications

Additional Resources These documents contain additional information concerning related Rockwell
Automation products.

Resource Description
Visualization Solutions Selection Guide, Provides an overview of the visualization
publication VIEW-SG001 products including catalog number selections
offered by Rockwell Automation.
PanelView 6 Terminals User Manual, publication Provides information on how to install, configure,
2711P-UM006 operate, and troubleshoot the PanelView Plus 6
(700 to 1500) terminals.
PanelView Plus 6 Terminals Installation Provides information on how to install the
Instructions, publication 2711P-IN029 PanelView Plus 6 (700 to 1500) terminals in a
panel.
PanelView Plus Compact Terminals User Manual, Provides information on how to install, configure,
publication 2711PC-UM001 operate, and troubleshoot the PanelView Plus
Compact terminals.
PanelView Plus Terminals User Manual, Provides information on how to install, configure,
publication 2711P-UM001 operate, and troubleshoot the PanelView Plus
400 and 600 terminals.
Industrial Automation Wiring and Grounding Provides general guidelines for installing a
Guidelines, publication 1770-4.1 Rockwell Automation industrial system.
Product Certifications website, Provides declarations of conformity, certificates,
http://www.ab.com and other certification details.

You can view or download publications at


http://www.rockwellautomation.com/literature/. To order paper copies of
technical documentation, contact your local Rockwell Automation distributor or
sales representative.

Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010


Important User Information
Solid-state equipment has operational characteristics differing from those of electromechanical equipment. Safety
Guidelines for the Application, Installation and Maintenance of Solid State Controls (publication SGI-1.1 available from
your local Rockwell Automation sales office or online at http://www.rockwellautomation.com/literature/) describes some
important differences between solid-state equipment and hard-wired electromechanical devices. Because of this difference,
and also because of the wide variety of uses for solid-state equipment, all persons responsible for applying this equipment
must satisfy themselves that each intended application of this equipment is acceptable.
In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the
use or application of this equipment.
The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and
requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or
liability for actual use based on the examples and diagrams.
No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or
software described in this manual.
Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation,
Inc., is prohibited.

Documentation Feedback
Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this
document, complete this form, publication RA-DU002, available at http://www.rockwellautomation.com/literature/.

Allen-Bradley, CompactLogix, ControlLogix, DH+, PanelView Plus, PanelView Component, FactoryTalk View Studio, FactoryTalk, FactoryTalk View ME, FactoryTalk ViewPoint,
Integrated Architecture, MicroLogix, PLC-5, SLC, RSLinx Enterprise, RSView32, Rockwell Software, Rockwell Automation are trademarks of Rockwell Automation, Inc.

Trademarks not belonging to Rockwell Automation are property of their respective companies.

Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400

Publication 2711P-TD005A-EN-P - November 2010 Copyright © 2010 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.

Das könnte Ihnen auch gefallen