WCDMA BTS
CN-id: 60229
Title:
Cells down during cold weather due to Radio module failure (125) -alarm
References:
It was noticed during freezing weather, that some of the sites equipped with FRGF put cells
faulty with raw alarm 125 (cell gain reduced). The BTS were updated to WN6.0 PP2.01
shortly. Earlier, during past 2-3 months, this fault was not playing a role in network. The
failure was initiated, when RF module was reseted due to BTS sw upgrade or autonomous
recovery reset.
As a workaround BTS SW was downgraded to WN6.0 PP1.2, which brought the cells back
on-air.
Root cause:
The root cause of the problem was caused by improper mode switching, which did not
allowed transmission to begin.
During radio module start up in low temperature, a special heating procedure is being
performed. This phase is necessary to protect the temperature-sensitive components.
Power amplifiers are being used as the heating element. When the procedure is over, these
amplifiers should be switched to their regular operation mode (transmitting).
Correction:
Mode switching from heating state to transmission enabled was corrected .
Effects on operator
Capacity & Performance: Cell availability
Modified components:
CN-id: 60230
Title:
Radio module failures of FRGF units
References:
Analysis:
It was found that runtime mode of digital adaptive pre distortion (DAPD) can be run from two
different reasons, and furthermore there was some probability that these events happen in
one after another. This allowed a situation at start of runtime mode on DAPD2 (after
second carrier activation), that there were two instances of the second DAPD's runtime
mode trying to perform Nulling LO and delay synchronization. This led delay estimation to
fail, because two 'instances' were trying to work on the same RF pipe.
Correction:
Problem is eliminated by allowing only one instance to initiate DAPD runtime mode at a
time.
Effects on operator
Operation and Maintenance: Unnecessary alarms, increase in recovery actions
Capacity & Performance: Cell availability
Modified components:
WCDMA BTS
CN-id: WN60228
Title:
Cells not always coming up at once with BTS software WN6.0 PP2.01
References:
Modified components:
Effects on end-user
Effects on Operator
Other effects
New functionality
Customer Impact
Due to the nature of the problem, it is difficult to define all the unexpected problems and
consequences that may occur for UltraSite BTS. So far it has been analyzed from the logs
that the problem causes occasional BTS cell set-up failures but also call performance
degradation is expected
Pre-requirements:
-
Test execution:
-
Expected results:
-
Unexpected results:
-
WCDMA BTS
CN-id: WN60193
Title:
External MHA (Other BTS MHA) greyed out in Site Manager view
References:
Root cause: Problem in alarm handling and MHA state update for external MHA (other BTS
MHA). Start timer for 'No connection to MHA unit' was missing and also MHA state was
incorrectly updated as 'lost' state to the database.
Correction: 'No connection to MHA unit' alarm start timer added and MHA state update to
the data base corrected.
Modified components:
Change effects:
Effects on end-user
Other effects
New functionality
Customer Impact
Operation & Maintenance: MHA greyed out in BTS Site Manager view.
Pre-requirements:
Test execution:
This correction cannot be tested using the operator interface commands. The correction is
tested internally in Nokia Siemens Networks test lab and proved to be fully functional
Expected results:
-
Unexpected results:
-
CN-id: WN60195
Title:
Mismatch with CPC counters
References:
Correction: When the last UE is deleted from the BTS, SUM_ACTIVE_CPC_USERS is set
to 0.
Modified components:
Effects on end-user
Effects on Operator
Other effects
New functionality
Customer Impact
Operability: SUM_ACTIVE_CPC_USERS in not updated correctly.
Pre-requirements:
Test execution:
This correction cannot be tested using the operator interface commands. The correction is
tested internally in Nokia Siemens Networks test lab and proved to be fully functional
Expected results:
-
Unexpected results:
-
CN-id: WN60196
Title:
License missing alarm even though licence status as active
References:
Root cause:
Timer was too short.
Correction:
Timer was increased.
67254ESPE04
60W license not being activated
67272ESPE04
FRGP: Fault Branch Activation License missing in Site Manager despite license is active
53165ESPE01
Branch activation licence missing after power reset
Modified components:
Effects on end-user
Effects on Operator
Other effects
New functionality
Customer Impact
Operability:
BTS Site Manager is displaying wrong information.
Pre-requirements:
-
Test execution:
-
Expected results:
-
Unexpected results:
-
CN-id: WN60197
Title:
MHA and RET not always recognized after BTS restart
References:
Root cause:
Some Antenna Line Devices (ALD) are not responding to XID Address Assignment
command.
Correction:
After first unsuccessful try the DC power is switched off / on and the whole procedure of
configure ALD devices is restarted
Modified components:
Change effects:
Effects on end-user
Effects on Operator
New functionality
Customer Impact
Capacity & Performance: MHA and RET devices are out of use causing degraded cell
availability.
Pre-requirements:
Test execution:
-
Expected results:
-
Unexpected results:
-
CN-id: WN60198
Title:
7653 Too many carriers allocated for LPA
References:
Root cause:
Local Cell Antenna mapping message was filled incorrectly in start-up when using ROC
configurations.
Correction:
Local Cell Antenna mapping message filling corrected.
Modified components:
Change effects:
Effects on end-user
Effects on Operator
Other effects
New functionality
Pre-requirements:
-
Test execution:
-
Expected results:
-
Unexpected results:
-
CN-id: WN60199
Title:
Site Performing Autonomous Restarts
References:
Root cause: Rake has not received all the BB_LOOP_DELAY_REPORT_REQ_MSG before
Telecom startup has begun. This was due to missing O&M requirement which allowed O&M
to mark FSP's as configured before it has configured loop delays to Faraday processors.
Correction: O&M implementation was modified so that RTT loop delays needs to configured
to all FSP Faradays before FSP is marked as "configured"
NA04782460:
FSPC autonomous reset with fault code 1806
Modified components:
Change effects:
Effects on end-user
Possibly dropped call.
Effects on Operator
Site was performing multiple autonomous restarts.
New functionality
Customer Impact
Pre-requirements:
-
Test execution:
-
Expected results:
-
Unexpected results:
-
CN-id: WN60201
Title:
Spontaneous FRGG reset
References:
Root cause:
Problem was caused by the memory leak in FRGG unit SW. Problem occurs when System
Module sends high amount of broadcast messages to the FRGG unit within short period of
time. Memory leak causes problems in Ethernet connection and FRGG is spontaneously
restarted.
Correction:
Memory leak has been corrected.
Modified components:
Effects on end-user
Effects on Operator
Other effects
New functionality
Customer Impact
Performance: calls might be dropped, when FRGG makes a reset. That causes also short
service break.
Pre-requirements:
-
Test execution:
-
Expected results:
-
Unexpected results:
-
CN-id: WN60202
Title:
FXDA: RF module led is red even no alarms are active
References:
Correction:
LED indication corrected to be in line with the module status.
Modified components:
Effects on end-user
Effects on Operator
Other effects
New functionality
Customer Impact
Operability:
Wrong LED status indication.
Pre-requirements:
-
Test execution:
-
Expected results:
-
Unexpected results:
-
CN-id: WN60203
Title:
HSPA setup success rate decreased
References:
Correction:
- userEntryTable indexing corrected in MngrCtrl Check_eRgchEHichCodes()-
- Added old E-HICH signature sequence index releasing to non-serving to serving reconfig.
NA04790068
HSPA setup successful rate decreased much suddenly
Modified components:
Change effects:
Effects on end-user
Effects on Operator
Other effects
Customer Impact
Pre-requirements:
-
Test execution:
-
Expected results:
-
Unexpected results:
-
CN-id: WN60204
Title:
Flexi Rel1 system module failed
References:
Problem:
FSN Sync Ind message was sent multiple times instead of once. It was leading to overload
in control plane signalling. Cumulative delay made receiving responses impossible which
lead to system failure.
Root cause:
Multiple message sending was not prevented.
Correction:
Safety check was added to ensure that only one message is sent.
67647ESPE04
WN6.0 EP1 Rel1, ERR/TUP_Cm ResetIndication:
Modified components:
Change effects:
Effects on end-user
Other effects
New functionality
Customer Impact
Stability problem in the network.
Pre-requirements:
Test execution:
-
Expected results:
-
Unexpected results:
-
CN-id: WN60205
Title:
Recommissioning fails with application error
References:
Root cause:
Recommissioning fails with application error.
When user is doing reconfiguration, Site Manager failed.
Correction:
Make sure each NTP server count only once when validate
recommissioning/reconfiquration.
Modified components:
Change effects:
Effects on end-user
Effects on Operator
Can not recommission.
When user doing reconfiguration, SEM crashed.
Other effects
Customer Impact
Operation & Maintenance
Pre-requirements:
-
Test execution:
-
Expected results:
-
Unexpected results:
-
CN-id: WN60206
Title:
UltraSite doesn't work correctly with Site Manager version 6.2.51
References:
Correction:
The class path for each product to point to a different version of jars is modified. Site EM
6.2.51 is compatible UltraSite and MetroSite as well.
Modified components:
Change effects:
Effects on end-user
NA
Effects on Operator
Operability & Maintenance: Only one version of Site Element Manager required for the SW
release.
Other effects
Customer Impact
Operability problem
Pre-requirements:
Test execution:
-
Expected results:
-
Unexpected results:
-
CN-id: WN60207
Title:
Site in continuous reset loop after ALD additional parameter modification
References:
Correction:
Handling procedures of ALD database modified
Modified components:
Effects on end-user
Effects on Operator
Other effects
New functionality
Customer Impact
Operation & Maintenance: Recovery actions required, site visit needed.
Pre-requirements:
Test execution:
-
Expected results:
-
Unexpected results:
-
CN-id: WN60208
Title:
Limited HSUPA throughput on Flexi with FSMD + 2 FRGP
References:
Dependency on configuration:
HSUPA traffic carried by FRGP radio module.
Modified components:
Effects on end-user
Low trough put in HSUPA service
Effects on Operator
Performance and capacity: Low trough put for HSUPA in cell
Other effects
New functionality
Customer Impact
Performance: lower HSUPA throughput.
Pre-requirements:
Test execution:
-
Expected results:
-
Unexpected results:
-
CN-id: WN60209
Title:
HSDPA remained down after HSDPA DSP failure
References:
Root cause:
Request for modification of HSDPA cell with PSCR (physical shared channel
reconfiguration) interrupts ongoing local recovery. One of subsystem (CCHH) got
modification and local delete request in the same time but in different TCOM instances.
Correction.
Local Resource Manager (LRM) informs first Global Resource Manager (GRM) about
recovery and after that CCHH. Modification can be done and mean while deletion request is
stored. CCHH's data aren't overwritten.
Modified components:
Change effects:
Effects on end-user
Effects on Operator
Other effects
New functionality
Customer Impact
Possibly no HSDPA service
Pre-requirements:
-
Test execution:
-
Expected results:
-
Unexpected results:
-