The TimeWatch TWC tenant override and billing system is a stand-alone unit which will interface to
virtually any building control system marketed today. The TimeWatch provides complete override
control through a voice-prompted telephone interface, which can be accessed from any touch-tone
telephone. Time clock function provides time-of-day and holiday schedules for up to 248 individual
loads.

The TWC system software compiles the stored override data for each tenant, and automatically
generates an invoice for override usage, utilizing hourly rates set by the owner for each tenant.

The TimeWatch system gives both the tenant and building owner the best solution when tenant
occupancy is required outside of the lease contract hours. The building owner will recover utility
expenses for system operation, and the tenant will have complete access to schedule override
times themselves.

The TimeWatch TWC is a stand-alone unit, and may be used in conjunction with third party EMS/BAS systems.

The TWC is accessed via a Windows graphics interface program, providing system setup and monitoring, along with
comprehensive invoice preparation.

Features

• Touch-tone access to voice prompted system provides overrides in 1 hour increments.


• Over 9,000 possible security codes available, with 100 active on any given application.
• Programmable custom voice messages allow operators to personalize each individual building system.
• Stand-alone operation or complete interaction with building automation systems.
• Time scheduling for on/off control of up to 248 individual loads.
• 15 daily control schedules with special and holiday times.
• Automatic tracking of override usage by tenant security code.
• Records date, time and duration of all overrides.
• Full invoice preparation based on rates determined by the site manager for tenant.
• Windows based installation and setup interface.
• Direct connection of on-site personal computer through RS232 port.
• Remote communications through on-board telephone modem allows off-site programming and interrogation of the
system, including full data retrieval.
• Requires a minimum of one (1) RBS eight output board for connection to loads or third party system.
• Program integrity provided by battery backed-up RAM which retains system operational program regardless of power
conditions for up to 5 years.
• Total system configuration of thirty-one (31) RBS controllers, providing a total point capacity of 248 individual loads.
• Daisy chain wiring configuration to output boards.
• Controller network communication bus length of up to 4000 feet.
• 120vac power
Controller Details

CAUTION 115 VAC


ON
FUSE: 1 AMP 250V

OFF
CAUTION: MORE THAN ONE DISCONNECT MAY
BE REQUIRED TO DE-ENERGIZE CIRCUIT

+12v +5v

+12

+5
GND

GND
CONN2

BOARD

COMPUTER CONTROL

COMPUTER CONTROL
ADDRESS

SHEILD

SHEILD
OPEN ENERGY
MANAGEMENT
MANUAL CONTROL

MANUAL CONTROL
LISTED 49C6

EQUIPMENT

PWR

PWR
RS-232 I/O

OUTPUT TOGGLE

OUTPUT TOGGLE
T/R T/R

T/R T/R
T/R T/R

T/R T/R
OFF MANUAL CONTROL O NLY

OFF MANUAL CONTROL O NLY


RESTART

UL

UL
PWR

PWR
R

R
SHEILD

SHEILD
ON

ON
COM COM
M. OUTPUT 8 M. OUTPUT 8

8
OUTPUT 7 OUTPUT 7

7
6

6
OUTPUT 6 OUTPUT 6

5
SYS. SYS.
ACTIVE ACTIVE
OUTPUT 5 OUTPUT 5

DIGITAL OUTPUT
TM 320

TIMEWATCH
OUTPUT 4 OUTPUT 4

TMS TIMEWATCH DIGITAL OUTPUT BOARD

4
TM
S
OUTPUT 3 OUTPUT 3

3
RJ11 PHONE

2
OUTPUT 2 OUTPUT 2
CONN5

1
SHEILD

PWR -

PWR+
T/R -
T/R+

GND

T/R -

T/R+

OUTPUT 1 OUTPUT 1
SPEAKER
EXT LED

View of open TimeWatch TWC Override Controller with 2 RSB Boards

Specifications

UL Listing: ANSI/UL 916

Temperature: 32o to 1250 fahrenheit


Humidity: 95% non-condensing

Input Power: Voltage: 115vac (-15% / +10%) 60hz


Current: 0.2 amp maximum

Ports: RS-485 output board comm


RS-485 Aux illiary comm
RS-232 Direct connect comm
RS-232 RJ-11 Modem

Enclosure: Nema 1 with thumbscrews

Dimensions: 14.2h x 14.0w x 3.5d

Weight: 13.0 lbs.