NAME OF WORK: CIVIL, STRUCTURAL, ELECTRICAL AND OTHER DEVELOPMENTAL WORKS

NAME OF PROJECT: CONSTRUCTION OF CAMPUS OF THE BIO-TECH SCIENCE CLUSTER (PHASE-1), FARIDABAD, HARYANA.
Bidding Doc. No.: A091/T-36/10-11/BB/01

Name of Bidder:

SCHEDULE OF RATES
SECTION- A- CIVIL WORKS

SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE


IN FIG (RS) IN WORDS (Rupees)

SUBHEAD I : EARTH WORK


1 1.1 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over
areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal
of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be leveled and neatly
dressed.

(a) All kinds of soil cum 1447

2 1.2 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over
areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal
of excavated earth, lead upto 50 m and lift upto 1.5 m, disposed earth to be levelled and
neatly dressed.

(a) Ordinary Rock cum 4076


(b) Hard Rock(Blasting prohibited) cum 10088

3 1.3 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in
foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including
dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated
soil and disposal of surplus excavated soil as directed, within a lead of 50 m.

(a) All kinds of soil. cum 732

Page-1 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

4 1.4 Excavation work in foundation trenches or drains not exceeding 1.5 m in width or 10 sqm on
plan including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out
the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m.

(a) Ordinary rock cum 1463


(b) Hard Rock (Blasting prohibited) cum 5115

5 1.5 Excavating trenches of required width for pipes, cables, etc including excavation for sockets,
and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the
excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth
including consolidating each deposited layer by ramming, watering, etc. and disposing of
surplus excavated soil as directed, within a lead of 50 m:

(a) Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia.
metre 100

6 1.6 Excavating trenches of required width for pipes, cables, etc, including excavation for sockets,
depth upto 1.5 m including getting out the excavated materials, returning the soil as required
in layers not exceeding 20 cm in depth including consolidating each deposited layers by
ramming, watering etc. stacking serviceable material for measurements and disposal of
unserviceable material as directed, within a lead of 50m :

a Ordinary rock
Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia.
metre 3775
b Hard Rock ( Blasting prohibited )
Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia.
metre 505

7 1.7 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc.
in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and
watering, lead up to 50 m and lift upto 1.5 m.
cum 6296

8 1.8 Extra for every additional lift of 1.5 m or part thereof in.
a All kinds of soil cum 593

b Ordinary or hard rock ( Blasting prohibited ). cum 9851

9 1.9 Supplying and filling in plinth with local sand under floors including, watering, ramming
consolidating and dressing complete. cum 1232

Page-2 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

1.10 Supplying chemical emulsion in sealed containers including delivery as specified.


10
a Chlorpyriphos/ Lindane emulsifiable concentrate of 20% litres 5066

1.11 Diluting and injecting chemical emulsion (to be supplied free of cost at site of work) for PRE-
CONSTRUCTIONAL ANTI-termite treatment and creating a continuous chemical barrier
under and all around the column pits, wall, trenches, basement excavation, top surface of
plinth filling, junction of wall and floor, along the external perimeter of building, expansion
joints, over the top surface of consolidated earth on which apron is to be laid, surroundings of
pipes and conduits etc complete as per specifications (Plinth area of the building at ground
floor only shall be measured for payment) - Chlorpyriphos emulsifiable concentrate 20% with
1% concentration.

11 sqm 10118

1.12 Supplying and filling of good earth(excluding rock) in trenches, plinth,sides of foundation etc.
in layers not exeeding 20 c.m. in depth, consolidating each deposited layed by ramming &
watering including royalty and carriage for all lead and lifts.
12 cum 6195

SUBHEAD II - CONCRETE WORK


2.1 Providing and laying in position, cement concrete of specified grade excluding the cost of
centering and shuttering - All work upto plinth level :
13
a) 1:2:4 (1Cement : 2Coarse sand : 4 graded stone aggregate 20 mm nominal size ).
cum 29
b) 1:3:6 (1Cement : 3 Coarse sand : 6 graded stone aggregate 20 mm nominal size ).
cum 37.25
c) 1:4:8 (1 Cement : 4 Coarse sand : 8 graded stone aggregate 40 mm nominal size).
cum 2008
d) 1:5:10 ( 1Cement : 5 Coarse sand : 10 graded stone aggregate 40 mm nominal size.
cum 1208

2.2 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness)
including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses,
string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets
etc. up to floor five level, excluding the cost of centering, shuttering and finishing :

14
1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
cum 60

Page-3 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

2.3 Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as
per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse
sand) including the cost of required centering, shuttering and finishing smooth with 6mm thick
cement plaster 1:3 (1 cement : 3 fine sand) on exposed surfaces complete.

15
a 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
cum 48

2.4 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement :
2 coarse sand : 4 graded stone aggregate 12.5mm nominal size).
16 sqm 655

2.5 Extra for providing and mixing water proofing material in cement concrete work @ 1 kg per
kg
17 50kg of cement. 172

2.6 Applying a coat of residual petroleum bitumen of penetration 80/100 of approved quality
using 1.7kg per square metre on damp proof course after cleaning the surface with brushes
and finally with a piece of cloth lightly soaked in kerosene oil.
18 sqm 655

2.7 Making plinth protection with 25mm thick Kota stone fixed with 12mm thick cement mortar 1:3
(1 cement : 3 coarse sand) over base concrete 75mm thick cement concrete 1:5:10 (1
cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) complete in all
respect.
19 sqm 1338

SUBHEAD III - RCC WORK


3.1 Centering and shuttering including strutting, propping etc. and removal of form for :
20
a) Foundations, footings, bases of columns, etc. for mass concrete. sqm 4092
b) Walls (any thickness) including attached pilasters, butteresses, plinth and string courses,
Suspended floors, roofs, landings, balconies and access platform.etc.
sqm 43272

c) Lintels, beams, plinth beams, girders, bressumers and cantilevers. sqm 28654
d) Columns, Pillars, Piers, Abutments, Posts and Struts. sqm 19665
e) Stairs, (excluding landings) except spiral-staircases. sqm 1275
f) Small lintels not exceeding 1.5m clear span, moulding as in cornices, window sills, string
courses, bands, copings, bed plates, anchor blocks and the like.
sqm 235

Page-4 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

3.2 Extra for additional height in centering, shuttering where ever required with adequate bracing,
propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5
m, for every additional height of 1 metre or part thereof (Plan area to be measured)

21
Suspended floors, roofs, landing, beams and balconies (Plan area to be measured).
sqm 757

3.3 Providing, hoisting and fixing up to floor five level precast reinforced cement concrete work in
string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like
including the cost of required centering, shuttering, finishing smooth with 6 mm thick cement
plaster 1:3 (1 cement : 3 fine sand) on exposed surfaces complete but excluding cost of
reinforcement with 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal
size).
22 cum 213

3.4 Providing perforated holes using 25mm dia. PVC pipes in Precast RCC drain covers of 75 to
100 mm length including cutting and fixing in position complete(depth of hole shall be
23 measured for pavement) metre 2005

3.5 Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position
24 and binding all complete.
Thermo-mechanically treated bars of Fe 500. kg 2673192

3.6 Providing and laying in position ready mixed concrete manufactured in fully automatic
batching plant and transported to site of work in transit mixer for all lead having continuous
agitated mixer, manufactured as per mix design of specified grade for reinforced cement
concrete work including pumping of R.M.C. from transit mixer to site of laying , excluding the
cost of centering, shuttering finishing and reinforcement including cost of admixtures in
recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve
workability without impairing strength and durability as per direction of the Engineer - in -
charge. M-25 grade Reinforced cement concrete by using min. 380kg of cement per cum of
concrete. All works up to floor V level.

25 cum 14764
26 3.7 Add for providing richer mixes at all floor levels.
Providing M-30 grade concrete by using 400kg of cement per cum of concrete instead of M-
25 grade R.M.C. cum 885

SUBHEAD IV - BRICK WORK

Page-5 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

4.1 Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in:
27
a) Cement mortar 1:4 (1 cement : 4 coarse sand) cum 1346
b) Cement mortar 1:6 (1 cement : 6 coarse sand) cum 824

4.2 Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level up to
floor V level in all shapes and sizes in :
28
a Cement mortar 1:4 (1 cement : 4 coarse sand) cum 415

4.3 Half Brick masonary with F.P.S. bricks of class designation 75 in superstructure above plinth
29 level to Floor V level.
a Cement mortar 1:4 (1 Cement : 4 Coarse sand) sqm 171

b Extra for providing and placing 2 Nos 6mm dia. M.S. bars at every third course of half brick
masonry. sqm 171

4.4 Brick work with clay flyash F.P.S. brick of class designation 75 in superstructure above plinth
30 level up to floor five level in :
a Cement mortar 1:6 ( 1 Cement : 6 Coarse sand ) cum 1407

4.5 Providing & fixing Autoclaved Aerated Cement blocks masonary with 200mm thick AAC
blocks in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand )
excluding M.S bars / anchors / ties / RCC band and PCC at all heights, lifts & leads,
scaffolding complete.
31 cum 7289

4.6 Providing & fixing Autoclaved Aerated Cement blocks masonary with 125mm thick AAC
blocks in superstructure above plinth level in cement mortar 1:4 (1 cement : 4 coarse sand )
including 2 no.6mm M.S bars at every third layer / anchors / ties / RCC band and PCC
including lifts & leads, scaffolding complete in all respect.
32 sqm 7984

SUBHEAD V - STONE WORK


5.1 Random rubble masonry with hard stone in foundation and plinth including levelling up with
cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20mm
nominal size) at plinth level with :
33
a Cement mortar 1:6 (1 cement : 6 coarse sand) cum 1066

Page-6 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

5.2 Random rubble masonry with hard stone in superstructure above plinth level and upto floor V
level including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12
graded stone aggregate 20mm nominal size) at window sills, celing level and the like with :

34
b Cement mortar 1:6 (1 cement : 6 coarse sand) cum 743

5.3 Stone work (machine cut edges) for wall lining etc. (veneer work) backing filled with a grout of
12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement
mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone
shade : (To be secured to the backing by means of cramps which shall be paid for
separately) :
35
White sand stone - Exposed face machine cut and table rubbed with rough backing.

a 30 mm thick sqm 5942

5.4 Providing and fixing stainless steel cramps of required size and shape for anchoring stone
wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2
(1 cement : 2 coarse sand) including making the necessary chases in stone and holes in
walls wherever required.
36 kgm 3169

SUBHEAD VI - MARBLE WORK


6.1 Marble work gang saw cut (polished and machine cut) of thickness 18mm for wall lining
(veneer work) in cement mortar 1:3 (1 cement : 3 coarse sand) including pointing with white
cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment to match
the marble shade: (To be secured to the backing by means of cramps, which shall be paid for
separately).
37
Area of slab upto 0.50 sqm sqm 2410

6.2 Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished)
machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations
of required size of approved shade, colour and texture laid over 20mm thick base cement
mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with
matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to
edge to give high gloss finish etc. complete at all levels.

38
a) Granite of any colour and shade
b) Area of slab over 0.50 sqm. sqm 1103

Page-7 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

6.3 Extra for providing edge moulding to 18mm thick marble stone counters, Vanities etc.
including machine polishing to edge to give high gloss finish etc. complete as per design
approved by Engineer-in-Charge.
39
a) Marble work metre 820
b) Granite work metre 11803

6.4 Extra for fixing marble /granite stone over and above corresponding basic item, in facia and
drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc.
40 complete. metre 159

6.5 Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen
platform, vanity counters and similar location in marble/Granite/stone work including
necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete.
41 each 185

6.6 Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50 cm
deep and 1.8 cm thick fixed in urinal partitions by cutting of chase of appropiate width with
chase cutter and embedding the stone in the chase with eppoxy grount or with cement
concrete 1:2:4 (1 cement:2 corse sand: 4 part graded stone aggregate 6 mm nominal size) as
per the direction of Engineer-in-charge and finished smooth.

42
a Granite stone of approved shade (both side polished) sqm 40

SUBHEAD VII - WOOD WORK


7.1 Providing wood work in frames of door, windows, clerestory windows and other frames,
43 wrought framed and fixed in position :
a second class teak wood cum 30

7.2 Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter
confirming to IS : 14616 and TADS 15:2001(Part B)including ISI mark black enameled MS
butt hinges with necessary screws as per direction of Engineer in charge and panneling with
panels of
44
(a) 12 mm thick prelaminated particle board (decorative lamination on both sides) grade 1,
medium density flat pressed, three layer particle board FPT 1 or graded wood particle board
FPT 1, conforming to IS :3087 with BWP type synthetic resin adhesive as per IS : 848 pre-
laminated conforming to IS :12823 Grade 1, Type II marked .

sqm 1483

Page-8 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

7.3 Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non
decorative type, core of block board construction with frame of 1st class hard wood and well
mached comercial 3 ply veneering with vertical grains or crossed bends and face veneers on
both faces of shutters.
45
a) 35 mm thick including ISI marked stainless steel butt hinges with necessary screws
sqm 406

7.4 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass
excluded) (overall area of door shutter to be measured) :
46
Rectangular or square sqm 8

7.5 Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).
47 sqm 1085

7.6 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats,
48 square or round bars etc. all complete.
Fixed to openings / wooden frames with rawl plugs screws etc. kgm 111306

7.7 Providing and fixing IS : 3564 marked aluminium extruded section body tubular type universal
hydraulic door closer with double speed adjustment with necessary accessories and screws
49 etc. complete. each 164

7.8 Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not
less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with
nuts and screws etc. complete :
50
a 300x16 mm each 33
b 250x16 mm each 762

7.9 Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than
grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with
necessary screws etc. complete :
51
a 250 x 10 mm each 1184
b 200 x 10 mm each 4403
c 150 x 10 mm each 3240
d 100 x 10 mm each 372

Page-9 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

7.10 Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and
a pair of lever handles with necessary screws etc. complete (best make of approved quality).
52 each 227

7.11 Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than
grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary
screws etc. complete :
53
a 125mm each 1482
b 100mm each 3236
c 75mm each 194

7.12 Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic
coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour
and shade with necessary screws etc. complete.
54
Double rubber stopper each 145

7.13 Providing and fixing decorative high pressure laminated sheet of plain/wood grain in
gloss/matt/suede finish with high density protective surface layer and reverse side of
adhesive bonding quality confirming to IS:2046 Type S including cost of adhesive of
approved quality.
55
1.00 mm thick sqm 1487

7.14 Providing and fixing stainless steel sheet of grade 308 machine cut 1.60mm thick of approved
quality on one face of 35mm thick flush doors shutters including cutting and stainless steel
screws etc complete.
56 sqm 357

7.15 Extra for providing ISI marked Stainless Steel butt Hinges instead of black enamelled M.S.
Butt hinges with necessary screws.(Shutter area to be measured)
57 sqm 1483

SUBHEAD VIII - STEEL WORK


8.1 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work,
including cutting, hoisting, fixing in position and applying a priming coat of approved steel
58 primer all complete: kg 101650

8.2 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and
3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete,
including applying a priming coat of approved steel primer.
59

Page-10 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

Using flats 30x6mm for diagonal braces and central cross piece. sqm 2

8.3 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths
interlocked together through their entire length and jointed together at the end by end locks
mounted on specially designed pipe shaft with brackets, side guides and arrangements for
inside and outside locking with push and pull operation complete including the cost of
providing and fixing necessary 27.5cm long wire springs grade No.2 and M.S. top cover of
required thickness for rolling shutters.

60
80x1.25mm M.S. laths with 1.25 mm thick top cover. sqm 75

61 8.4 Providing and fixing ball bearing for rolling shutters each 20

8.5 Extra for providing grilled rolling shutters manufactured out of 8 mm dia MS bar instead of
laths as per design approved by Engineer-in-charge. (Area of grill to be meaured)
62 sqm 15

8.6 Steel work in built up tubular trusses including cutting, hoisting fixing in position and applying
a priming coat of approved steel primer, welded and bolted including special shaped washers
63 etc. complete.
Hot finished welded type tubes. kg 13000

8.7 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp of
internal dia 140mm, 73mm height, top lid of 1.5mm thick M.S. sheet with its top surface
hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by
means of 3.3mm dia. round headed screws, one lock at the corners. Clamp shall be made of
12mm dia M.S. bar bent to shape as per standard drawing.

64 each 1244

8.8 Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in
position and applying a priming coat of approved steel primer using structural steel etc. as
65 required.
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
kgm 9204

Page-11 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

8.9 Providing and fixing stainless steel staircase railing, 915 mm ht from floor level with 38 mm
dia AISI 316 grade SS hand rail (Wall thickness 1.50mm),38mm dia. AISI 316 grade S.S top
mounted round Baluster with glass holding accessories (including top bracket to hold hand
railing), 10mm thick toughened frosted glass (600 mm height). Distance between two vertical
baluster approx 1200mm etc and including installation complete, as per drawing no 08008B-
S5-AD-801 and instruction of Engineer-in-charge

66 Metre 375

8.10 Providing and fixing steel cage made with welded-mesh 75x25 with mild steel wires of 4 mm
dia , welded over M.S iron frame 25x25x5 mm around and welding M.S flat iron 25x3 mm at
junction of mesh and angle iron frame,making small door opening and making locking
arrangement as per Arch. drawing and including priming coat of approved steel primer as per
instruction of Engineer incharge (mild steel section shall be separately paid under item no
8.1).
67 sqm 5450

8.11 Providing and fixing welded mesh 75x25 mm with mild steel wire 4mm dia.for steel doors
welded over M.S steel section, including providing and fixing necessary butt hinges, and
locking arrangement, complete and applying primer coat of approved steel primer as per
instruction of Engineer-in-charge. (Mild steel section shall be separately paid under item no.
8.1)
68 sqm 135

SUBHEAD IX - FLOORING WORK


9.1 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate)
finished with a floating coat of neat cement including cement slurry, but excluding the cost of
nosing of steps etc. complete.
69
40mm thick with 20mm nominal size stone aggregate. sqm 2824

9.2 52 mm thick cement concrete flooring with concrete hardener topping under layer 40 mm
thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement
hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume .hardening
compound is mixed @ 2 litre per 50kg of cement or as per manufacturers specifications. This
includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.

70 sqm 801

Page-12 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

9.3 Marble stone flooring with 18mm thick marble stone (sample of marble shall be approved by
Engineer-in-charge) over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4
coarse sand) laid and jointed with white cement slurry mixed with pigment including rubbing
and polishing complete with :
71
Udaipur green marble. sqm 1160

9.4 Cement plaster skirting (up to 30 cm height) with cement mortar 1:3 (1 cement : 3 coarse
sand) finished with a floating coat of neat cement :
72
18 mm thick sqm 55

9.5 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with white
cement slurry mixed with pigment to match the shade of the slab including rubbing and
polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
73
25 mm thick sqm 11481

9.6 Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm
(average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with white cement
slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing
complete.
74 sqm 1291

9.7 40 mm thick fine dressed stone flooring over 20 mm (average)thick base of cement mortar
1:5 (1 cement : 5 coarse sand) including pointing with cement mortar 1:2 (1 cement : 2 stone
dust) with an admixture of pigment to match the shade of stone(size of stone slab is to be
decided by the Engineer in charge)
75
White Sand Stone sqm 665

9.8 Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab.
76 metre 2072

9.90 Extra for Kota stone/ sand stone in treads of steps and risers using single length up to 1.05
77 metre . sqm 620

9.10 Providing and fixing Granite stone flooring with 18mm thick granite ( Sample of granite stone
shall be approved by the Engineer-in-Charge ) over 20 mm(average) thick base of cement
mortar 1:4 ( 1 Cement : 4 Coarse sand ) laid and grouted with white cement mixed with
pigment of approved colour, jointing with white cement slurry including rubbing and polishing
complete.
78 sqm 1576

Page-13 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

9.11 Providing and laying Granite stone slab 18 mm thick in risers of steps , skirting and pillars laid
on 12 mm ( average ) thick cement mortar 1:3 ( 1 cement : 3 coarse sand ) jointed with grey
cement slurry mixed with pigment to match the shade of the slab , including rubbing &
polishing complete.
79 sqm 2681

9.12 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to
be specified by the manufacture ) of approved make in all colours, shades except burgundy,
bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps
and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and
jointing with white cement slurry @ 3.3kg per sqm including pointing in white cement mixed
with pigment of matching shade complete.

80 sqm 2652

9.13 Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the
manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as
White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4
Coarse sand) including pointing the joints with white cement and matching pigment etc.,
complete.
81 sqm 9581

9.14 Providing and laying mirror polished granite stone flooring with 18mm thick granite stone
(shade and sample of granite stone shall be approved by the Architect / Engineer-in-charge)
over 20mm (average) thick base of cement mortar 1:4 (1 cement 4 coarse sand) laid and
grouted with white cement mixed with pigment of approved colour, jointing with grey cement
slurry including rubbing and polishing complete.

82 sqm 2975

9.15 Providing and laying mirror polished granite stone slab 18mm thick in risers of steps, skirting,
dado and pillars laid on 12mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand)
and jointed with white cement slurry including treating the joints with cement mixed with
pigment to match the shade of the slabs, including rubbing & polishing complete.

83 sqm 567

Page-14 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

9.16 Extra for providing pre-finished 18mm thick full round nosing in treads of steps made up by
pasting (with approved adhesive) additional length of 50mm wide and 18mm thick granite
stone strip to granite stone steps including machine polishing to nosing to give high gloss
finish complete as per design approved by the Architect / Engineer-in-charge.

84 mtrs 90

9.17 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the
manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of
approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :
4 coarse sand) including grouting the joints with white cement and matching pigments etc.,
complete.
85
Size of Tile 60 x 60 cm sqm 13189

9.18 Providing and laying vitrified tiles of size as approved in skirting / dado laid on 12mm thick
bed of cement mortar 1:3 (1 cement : 3 coarse sand) & jointed with white cement slurry @
3.3 kg/sqm including pointing with white cement mixed with pigment of matching shade
complete.
86 sqm 10125

SUBHEAD X - ROOFING
10.1 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1
cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C.
sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1 cement : 3 coarse sand)
and a coat of neat cement rounding the edge sand making and finishing the outlet complete.

87 each 176

10.2 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :
13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for
thermal expansion.(i) Single socketed pipes.
88
110 mm diameter metre 2886

10.3 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for
unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing
with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.
89
a Coupler
110 mm each 339
b Bend 87.5 degree
110 mm bend each 176

Page-15 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

c Shoe (plain)
110 mm each 176

10.4 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC
rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of
required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4
coarse sand) and making good the wall etc. complete.

90
110 mm each 2389

10.5 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and
91 weighing not less than 440 grams. each 176

10.6 Providing and fixing at all height false ceiling including providing and fixing of frame work
made of special sections power pressed from M.S. sheet and galvanised in accordance with
zinc coating of grade 350 as per IS : 277 and consisting of angle cleats of size 25mm wide x
1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to
the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle
hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with
nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre
to which the ceiling section 0.5mm thick button wedge of 80mm with tapered flanges of
26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction
perpendicular to

92 sqm 22953
G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every
junction including fixing the gypsum board with ceiling section and perimeter channels 0.5mm
thick 27mm high having flanges of 20mm and 30mm long, theperimeter of ceiling fixed to
wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all
screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square
edges of the board with recommended filler, jointing tapes, finisher and two coats of primer
suitable for board as per manufactures specification and also including the cost of making
openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels
suitably fixed all complete as per drawing and specification and direction of the Engineer in
Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum board
conforming to IS: 2095- Part I.

Page-16 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

10.7 Providing and fixing thermal insulation of ceiling ( under deck insulation ) / wall with 75 mm
thick Dupont subtex insulation of polyster wool with mass , 600 grams per square meter, and
thermal insulation ' R ' value 1.12 sqm W/K. Backed with 82 gm tyvek air and water barrier,
vapour breathable non woven substrate made of HDPE , fixed to ceiling with metallic
insulation fastening pins of 100 mm length, washers and secured with the help of wire mesh
of 22 x 18 mm for top most ceiling of the building.

93 sqm 7001

10.8 Providing, installing/fixing skylight consisting of 10 mm thick multiwall Polycarbonate sheet


( GE make ) of required shade fixed to aluminium profile frame work with stainless steel
screws and supported on M.S tube frame work including EPDM gasket, GE silicon sealent
cold forged fasteners etc complete as per drawing no 08008A2-S5-AP001 and direction of
Engineer-in-Charge. The rate includes the cost of all the operations, labour, materials and
tests ( as applicable ) for proper completion of the work except for the M.S tubular framework
which shall be measured and paid separately under item no. 8.6 . ( For payment purpose the
area of finished polycarbonate sheet fixed in position shall only be measured ).

94 sqm 520

SUBHEAD XI - FINISHING WORK


95 11.1 12 mm cement plaster of mix :
1:6 ( 1 Cement : 6 Fine sand ) sqm 48936

11.2 15 mm cement plaster on the rough side of single or half brick wall of mix :
96
1:6 ( 1 Cement : 6 Fine sand ) sqm 24647

11.3 12 mm cement plaster finished with a floating coat of neat cement of mix :
97
1:3 (1 cement: 3 fine sand) sqm 933

11.4 15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat
cement on the rough side of single or half brick wall.
98 sqm 6306

99 11.5 6 mm cement plaster of mix :


1:3 ( 1 Cement : 3 Fine sand ) sqm 66650

Page-17 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

11.6 Providing and applying plaster of paris putty of minimum 2 mm thickness over plastered
surface to prepare the surface even and smooth complete.
100 sqm 122685

11.7 Pointing on stone work with cement mortar 1:3 (1 cement: 3 fine sand) :
101
Flush / Ruled Pointing sqm 1142

11.8 Distempering with 1st quality acrylic washable distemper (ready mixed) of approved
manufacturer and of required shade and colour complete. as per manufacturer's
102 specification.
Two or more coats on new work. sqm 137158

103 11.9 Applying primary coat :


a With ready mixed pink or Grey primer of approved brand and manufacture on wood work
(hard and soft wood) sqm 2601
b With ready mixed red oxide zinc chromate primer of approved brand and manufacture on
steel galvanised iron/steel works sqm 2712

11.10 Painting (two or more coats) on rain water, soil, waste and vent pipes and fittings with
synthetic enamel paint of approved brand and manufacture and required colour over a
priming coat of approved steel primer on new work.
104
a 100 mm diameter pipes metre 205
b 150 mm diameter pipes metre 1530

11.11 Painting with synthetic enamel paint of approved brand and manufacture to give an even
105 shade
Two or more coats on new work sqm 11547

11.12 Washed stone grit plaster on exterior walls of height upto 10m above level in two layers,
under layer 12mm cement plaster 1:4 (1 cement : 4 coarse sand) furrowing the under layer
with scratching tool, applying cement slurry on the under layer @ 2 kg of cement per square
metre, top layer 15mm cement plaster 1:1/2:2 (1 cement : 1/2 coarse sand : 2 stone chipping
10mm nominal size) in panels with groove all around as per approved pattern including
scrubbing and washing, the top layer with brushes and water to expose the stone chippings,
complete as per specification and direction of Engineer-in-charge (payment for providing
grooves shall be made separately).

106 sqm 16041

Page-18 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

11.13 Forming groove of uniform size in the top layer of washed stone grit plaster as per approved
pattern using wooden battens, nailed to the under layer including removal of wooden battens,
repair to the edges of panels and finishing the groove complete as per specifications and
direction of the Engineer-in-charge including finishing the groove with silicon treatment of
approved make complete.
15mm wide and 15mm deep groove.
107 mtrs 16041

11.14 Providing and laying white sand stone (Dholpur) strips 50mm wide 20mm thick in fixed over a
bed of 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) over external surface of
wall, including joints filled with white cement slurry and pointing with matching shade
complete.
108 mtrs 16885

11.15 Providing & fixing tray type ALUMINIUM COMPOSITE SHEET CLADDING OVER STEEL
FRAME WORK using Aluminium mill finish rectangular verticle tube size -50x150x2mm
having wt. 2.13kg/m & horizontal square tube size 50x50x2mm having weight 1.043 kg/m
including 4mm thick aluminum composite panel sheet with 0.5mm aluminium foil thickness,
backer rod, & the periphey of cladding panel shall be sealed with weather Silicone of Dow
Corning/Walker make, necessary screws & hardware etc., complete in all respect.

109 sqm 2925

11.16 Providing and fixing toilet cubicles with intermediate panel, Pilaster & door. The intermediate
panel is one continued panel without any joints. All intermediate panels,pilasters and doors
shall be 12mm thick with edges chamfered. The solid compact laminate ( Phenolic Core
Board) is based on thermosetting resins, homogeneously reinforced with cellulose fibres. Top
surface on both sides is melamine coated which is scratch and impact resistant, including
cost of self closing S.S hinges, adjustable legs, lock with indicator & coat hanger of approved
make complete as per architectural drawing no.08008B-S5-AD-301 & direction of Engineer-
in-Charge.

110 sqm 730

Page-19 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

11.17 Providing & fixing canopy with 16 mm thick multi cell poly-carbonate sheet of approved make,
projecting out from terrace level of THSTI/RCB Block and coping the end edge of canopy with
Aluminium U-channel, as per section mentioned in the drawing with polycarbonate U-profile
holding arrangement with cap at the end over the M.S section frame duly fixed with RCC.
Column/Beam/M.S box section including priming coat of approved steel primer complete as
per drawing no.08008B-S5-AD 703. ( M.S. frame work shall be paid for separately ).

111 sqm 180

11.18 Providing and fixing 38 x 38 mm glazed ceramic tiles of versatile venetia band or equivalent
on exterior wall face with Laticrete 30% adhesive as per manufacturer specification and
grouting the joints with Latapoxy grouts of required shade complete as per the directions of
Engineer-in-Charge.
112 sqm 1755

11.19 Providing & fixing Microcell Danpalon Panel system 16mm thick (minimum) conforming to
following specifications.The polycarbonate system consist of : 1)Panel shall be 16mm thick
(min.)single panel.2)Panel width shall not be less than 1040 mm to ensure best performance
for wind uplift, vibration, oil canning & visual appearance.3) The panels shall be uniform in
colour with an integral Microcell core. In a cross section, the core shall be constructed of tight
cells not to exceed 4mm x 4mm. Wide cell panel configurations greater than 4mm by 4mm
shall not be accepted. 4) The weight of the panel shall not be les than 3250gram per square
meter. 5)Panels shall be manufactured with Vertical Standing Seam at both sides of the
panel. Welding or gluing of upstands or standing seam is not acceptable. 6) Snap-on
connector to interlock the panels shall have a grip-lock double tooth locking mechanism to
ensure maximun uplift capability. 7) End-cap/Aluminium U-Profile (mill finish ) for ends. 8)
Panels shall be co-extruded UV protected and double tone with anti-glare

softlite colour on one side to prevent glare. 9) Panel manufacturer should have project
reference in India which is atleast 6 years old for a single project not less than 1,500sqm. UV
protected side shall always face the sun/top. The full system shall be fitted on MS purlins
perpendicular to direction of sheeting with purlin spacing as specified by the manufacturer.
Panels shall be secured with snap-on connectors. Panels shall be installed by a solution
provider and is including the cost of required M.S. purlins and is as per architectural drawing
no. 08008D-S5-AD 801. .

113 sqm 226

SUBHEAD XII - SANITARY INSTALLATIONS

Page-20 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

12.1 Providing and fixing water closet squatting pan low floor (Indian type W.C. pan) with 100mm
sand cast Iron P or S trap, 6 litre low level white P.V.C. 2/4 ltrs dual flushing cistern with
manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures
complete including cutting and making good the walls and floors wherever required :

114
White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot
rests. each 2

12.2 Providing and fixing white vitreous china wall mounted European type water closet (of
approved make) with CP bolts, nuts, CI chair or other hanging arrangement, with vitreous
china watersaver dual flush 6 ltrs flushing cistern and internal fittings, white solid
plastic/wooden/bakelite seat and cover with lid, CP brass hinge rubber buffers, with
accessories, CI/MS brackets painted with two or more coats of enamel paint of approved
shade over a coat of primer. C.P. brass screws and wooden cleats, including cutting and
making good the wall and floors wherever required.

115 each 164

12.3 Providing and fixing white vitreous china flat back or wall corner type lipped front low floor
urinal basin of 430x260x350mm and 340x410x265mm sizes respectively with automatic
electronic flushing cistern with standard flush pipe and C.P. brass spreaders with brass
unions and G.I clamps complete, including painting of fittings and brackets, cutting and
making good the walls and floors wherever required :

116
One urinal basin with 5 litre white P.V.C. automatic flushing cistern. each 48

12.4 Providing and fixing white viterous china Oval shaped wash basin of approved make of size
560 x 410 mm counter sunk with 32 mm dia. C.P.brass wastepipe, 15 mm C.P brass pillar
tap Gem/ Parko or equivalent make including cutting and making good the wall etc. wherever
required as per direction of the Engineer-in-Charge.
117 each 186

12.5 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I.
brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting
and making good the walls wherever required :
118
Kitchen sink with drain board
510x1040 mm bowl depth 250mm each 1

Page-21 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

12.6 Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain
with rubber plug 40mm C.P brass waste and 40mm C.P. brass trap with necessary C.P.
brass unions complete including painting of fittings and brackets, cutting and making good
the wall wherever required :
119
Size 600x450x200 mm each 88

12.7 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings
120 complete.
Flexible Pipe
32 mm dia each 175

12.8 Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality)
complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws
and washers complete.
121 each 186

122 12.9 Providing and fixing toilet paper holder :


C.P. brass each 164

123 12.10 Providing and fixing soil, waste and vent pipes :
a 100 mm dia.
Centrifugally cast (spun) iron socketed pipe as per IS: 3989 metres 1205
b 75 mm dia.
Centrifugally cast (spun) iron socketed pipe as per IS: 3989 metres 1205

12.11 Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron
(spun) pipe embedded in and including cement concrete blocks 10x10x10cm of 1:2:4 mix (1
cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of
cutting holes and making good the walls etc. :
124
a For 100 mm dia pipe each 375
b For 75 mm dia pipe each 491

12.12 Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm
125 thick, bolts and nuts complete
a 100 mm dia
Sand cast iron S&S as per IS - 3989 each 145
b 75 mm dia
Sand cast iron S&S as per IS- 3989 each 87

126 12.13 Providing and fixing plain bend of required degree.

Page-22 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

a 100 mm
Sand cast iron S&S as per IS - 3989 each 36
b 75 mm
Sand cast iron S&S as per IS - 3989 each 40

127 12.14 Providing and fixing heel rest sanitary bend.


a 100 mm dia.
Sand cast iron S&S as per IS - 3989 each 23
b 75 mm dia.
Sand cast iron S&S as per IS - 3989 each 24

12.15 Providing and fixing single equal plain junction of required degree with access door, insertion
rubber washer 3 mm thick, bolts and nuts complete.
128
a 100 x 100 x 100 mm
Sand cast iron S&S as per IS - 3989 each 55
b 75 x 75 x 75 mm
Sand cast iron S&S as per IS - 3989 each 74

129 12.16 Providing and fixing terminal guard:


a 100 mm
Sand cast iron S&S as per IS - 3989 each 32
b 75 mm
Sand cast iron S&S as per IS - 3989 each 41

130 12.17 Providing and fixing collar:


a 100 mm
Sand cast iron S&S as per IS - 3989 each 126
b 75 mm
Sand cast iron S&S as per IS - 3989 each 180

12.18 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings
131 of diameter:
a 100 mm each 950
b 75 mm each 775

12.19 Providing and fixing M.S. stays and clamps for sand cast iron/centrifugally cast (spun) iron
132 pipes of diameter
a 100 mm each 35
b 75 mm each 40

Page-23 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

12.20 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or
without vent arm complete, including cost of cutting and making good the walls and floors :
133
a 100 mm inlet and 100 mm outlet
Sand cast iron S&S as per IS - 3989 each 388
b 100 mm inlet and 75 mm outlet
Sand cast iron S&S as per IS - 3989 each 29

12.21 Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with
paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved
134 quality) for new work :
a 100 mm diameter pipe metre 668
b 75 mm diameter pipe. metre 613

12.22 Providing and fixing C.P.brass jali 100 mm dia of approved make floor type.
135 each 388

136 12.23 Providing and fixing C.P. brass Bottle Trap for Wash basin and sink.
Bottle trap 38mm single piece moulded with height of 270mm, effective length of tail pipe
260mm from the centre of the waste coupling 77mm breadth with 25mm minimum water seal,
weighing not less than 263gms.
each 25

12.24 Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm
distance from wall of standard shape with bracket of the same materials with snap fittings of
approved quality and colour. weighing not less than 105 gms.
137 each 92

12.25 Providing and fixing C.P.brass towel ring trapezoidal shape of approved make 215mm long,
200mm wide with a minimum distances of 37mm from wall face with concealed fittings
arrangement of approved quality
138 each 25

12.26 Providing and fixing C.P. towel rail complete with brackets fixed to wooden cleats with CP
brass screws with concealed fitting arrangement of approved quality .
139 each 10

12.27 Providing & fixing 125mm dia.3mm thick Stainless steel grating with frame for floor traps or
drains of required pattern including cutting & making good the floors complete.
140 each 29

Page-24 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

12.28 Providing & fixing C.P brass Health faucet with PVC Flexible Tube with wall hook of approved
141 make each 6

12.29 Extra for providing & fixing automatic flushing system to ensure flushing of urinal after being
used comprising of flush valve, all plumbing valves (solenoid valves etc.) automatic electronic
censors, PVC conduit, concealed copper wiring etc & any other items required to provide
satisfactorily functioning of system in place of PVC automatic flushing cistern of approved
make.
142 each 42

SUBHEAD XIII - WATER-SUPPLY

13.1 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for
hot & cold water supply including all CPVC plain & brass threaded fittings This includes
jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of
joints complete as per direction of Engineer in Charge.
143
62.50 mm nominal inner dia Pipes. metre 590

13.2 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and
144 making good the walls etc.
a 15 mm dia nominal bore metre 82
b 20 mm dia nominal bore metre 541
c 25 mm dia nominal bore metre 1753
d 32 mm dia nominal bore metre 50
e 40 mm dia nominal bore metre 50
f 50 mm dia nominal bore metre 50

13.3 Providing & fixing G.I pipes complete with G.I fittings & clamps including making good the
walls etc, Concealed pipe including painting with anti corrosive bitumastic paint, cutting
chases and making good the wall
145
a 15 mm dia nominal bore metre 1134
b 20 mm dia nominal bore metre 1635

13.4 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.
External Work.
146
a 65 mm dia. nominal bore metre 300
b 80 mm dia. nominal bore metre 1700
c 100 mm dia. nominal bore metre 4045

Page-25 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

13.5 Making connection of G.I. distribution branch with G.I. main of following sizes by providing
and fixing tee, including cutting and threading the pipe etc. complete :
147
a 25 to 40 mm nominal bore each 4
b 50 to 80 mm nominal bore each 5

13.6 Providing & fixing gun metal gate valve with C.I wheel of approved quality ( screwed end ) :
148
a 25mm nominal bore each 2
b 65 mm nominal bore each 12
c 80 mm nominal bore each 20
d 100 mm nominal bore each 10

13.7 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic
149 floats complete :
a 20 mm nominal bore each 20
b 25 mm nominal bore each 5

13.8 Providing and fixing uplasticised PVC connection pipe with brass unions
150
a 45 cm length
(i) 15 mm nominal bore each 540

151 13.9 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :
100 mm diameter each 2

13.10 Constructing masonry Chamber 30x30x50 cm, inside with 75 class designation brick work in
cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100
x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement :2
coarse sand : 4 graded stone aggregate 20 mm nominal size ) necessary excavation
foundation concrete 1:5:10 ( 1 cement :5 fine sand:10 graded stone aggregate 40mm
nominal size ) and inside plastering with cement mortar 1:3 (1 cement :3 coarse sand) 12mm
thick finished with a floating coat of neat cement complete as per standard design :

152
With F.P.S. bricks each 42

Page-26 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

13.11 Constructing masonry Chamber 90x90x100 cm, inside with 75 class designation brick work in
cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm.
top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC
top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size
) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand:10 graded stone
aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3
coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per
standard design :

153
With F.P.S. bricks each 2

13.12 Constructing masonry Chamber 60x60x75 cm, inside with 75 class designation brick work in
cement mortar 1:4 (1 cement : 4 coarse sand) for fire hydrants, with C.I. surface box 350x350
mm. top and 165 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement :
2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation
foundation concrete 1:5:10 (1 cement : 5 fine sand:10 graded stone aggregate 40 mm
nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm
thick finished with a floating coat of neat cement complete as per standard design :

154
With F.P.S bricks each 10

13.13 Painting G.I. pipes and fittings with synthetic enamel white paint over a ready mixed priming
155 coat, both of approved quality for new work :
a 15 mm diameter pipe metre 82
b 20 mm diameter pipe metre 541
c 25 mm diameter pipe metre 1753
d 32 mm diameter pipe metre 50
e 40 mm diameter pipe metre 50
f 50 mm diameter pipe metre 50

13.14 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved
156 quality :
a 15 mm diameter pipe metre 1134
b 20 mm diameter pipe metre 1615
c 65 mm diameter pipe metre 300
d 80 mm diameter pipe metre 1700
e 100 mm diameter pipe metre 4045

Page-27 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

13.15 Providing and filling sand of grading zone V or coarser grade all-round the G.I. pipes in
157 external work.
a 65 mm diameter pipe metre 300
b 80 mm diameter pipe metre 1700
c 100 mm diameter pipe metre 4045

13.16 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and
158 making long screws etc. complete (New work)
a 15 mm nominal bore each 65
b 20 mm nominal bore each 73
c 25 mm nominal bore each 65
d 32 mm nominal bore each 8
e 40 mm nominal bore each 8
f 50 mm nominal bore each 8
g 65mm nominal bore each 5
h 80 mm nominal bore each 10
i 100 mm nominal bore each 10

13.17 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI :
12701 marked with cover and suitable locking arrangement and making necessary holes for
inlet, outlet and overflow pipes but without fittings and the base support for tank.
159 litres 33000

13.18 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931
160
15 mm nominal bore each 180

13.19 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS
standards and weighing not less than 690 gms.
161
15 mm nominal bore each 89

13.20 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved
162 make conforming to IS:8931.
15 mm nominal bore each 572

13.21 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved
quality conforming to IS:8931 a) 15 mm nominal bore .
163
15 mm nominal bore each 202

Page-28 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

13.22 Providing and laying Double Flanged (screwed/ welded) Centrifugally (Spun) Cast Iron, Class
164 B (IS : 1536) :
100 mm dia C.I. Double Flanged Pipe metre 542

13.23 Providing and laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) Ductile Iron
Pipes of Class K - 9 conforming to IS : 8329 :
165
a 100 mm dia Ductile Iron Double Flanged metre 45
b 150 mm dia Ductile Iron Double Flanged metre 10
c 200 mm dia Ductile Iron Double Flanged metre 5

13.24 Cutting holes up to 15x15cm in R.C.C. floors and roofs for passing drain pipe etc. and
repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement :2
coarse sand : 4 graded stone aggregate 20 mm nominal size) mixed with water proofing
liquid compound including finishing complete so as to make it leak proof.(The job has to be
executed through a reputed agency dealing with water proofing work.)

166 each 45

13.25 Providing & fixing 15mm C.P brass two-way bib tap with C.P brass threaded flange complete,
including cutting and making good the walls wherever required, of approved brand &
167 manufacture. each 6

13.26 Providing & fixing 15 mm C.P. brass wall/counter mounting single hole mixture(of approved
make) fitting for kitchen sink/ wash-basin with swinging and Swivel spout complete including
cutting and making good the walls wherever required.
168 each 11

13.27 Providing & fixing 15mm C.P Laboratory Cock swan neck (of approved make ) in centre with
side nozel bib cocks three way complete including cutting and making good the walls where
required.
169 each 14

13.28 Providing & fixing 15mm C.P brass wall mounting auto self closing bib cock (of approved
make ) complete including cutting & making good the walls where required.
170 each 600

SUBHEAD XIV - DRAINAGE


14.1 Providing, laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement
mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete
171 :
a 100 mm diameter metre 20

Page-29 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

b 150 mm diameter metre 315


c 200 mm diameter metre 1020
d 300 mm diameter metre 114

14.2 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone
aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard
172 design:
a 100 mm diameter S.W. pipe metre 10
b 150 mm diameter S.W. pipe metre 250
c 200 mm diameter S.W. pipe metre 204

14.3 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone
aggregate 40 mm nominal size) upto Haunches of S.W. pipes including bed concrete as per
standard design:
173
a 100 mm diameter S.W. pipe metre 10
b 150 mm diameter S.W pipe metre 45
c 200 mm diameter S.W. pipe metre 816
d 300 mm diameter S.W. pipe metre 114

14.4 Providing and fixing square-mouth S.W. gully trap grade 'A'’ complete with C.I. grating brick
masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the
weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per
standard design :
174
100 x 100 mm size P type
a With FPS bricks class designation 75 each 46

14.5 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed
with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including
testing of joints etc. complete :
175
300 mm dia. R.C.C. pipe metre 500

Page-30 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

14.6 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand )
R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone
aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1
cement : 3 coarse sand) finished with floating coat of neat cement and making channels in
cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal
size) finished with a floating coat of neat cement complete as per standard design :

176
a Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610
mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of
cover 23 kg and weight of frame 15 kg) :

With FPS bricks class designation 75 each 43


b Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500
mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of
cover 58 kg and weight of frame 58 kg) :

With F.P.S. bricks class designation 75 each 5

177 14.7 Extra for depth for manholes.


a Size 90x80 cm
With F.P.S. bricks class designation 75 metre 1
b Size 120x90 cm
With F.P.S. bricks class designation 75 metre 1

14.8 Constructing brick masonry circular type manhole 0.91m internal dia at bottom and 0.56m dia
at top in cement mortar 1:4 (1 cement :4 coarse sand), in side cement plaster 12 mm thick
with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat
cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate
40mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2
coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of
neat cement all complete as per standard design :

178
0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560mm
internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than
182kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate
20 mm nominal size) including centering shuttering all complete. (Excavation, foot rests and
12mm thick cement plaster at the external surface shall be paid for separately) :

Page-31 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

With F.P.S. bricks class designation 75 each 22

14.9 Constructing brick masonry circular manhole 1.22m internal dia at bottom and 0.56m dia at
top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12mm thick with
cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement
foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm
nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse
sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat
cement all complete as per standard design :

179
1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560mm
internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than
182kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate
20mm nominal size) including centering shuttering all complete. (Excavation, foot rests and
12 mm thick cement plaster at the external surface shall be paid for separately) :

With F.P.S. bricks class designation 75 each 22

14.10 Extra depth for circular type manhole 0.91m internal dia (at bottom) with beyond 0.91m to
180 1.67m
With F.P.S. bricks class designation 75 metre 20

14.11 Extra depth for circular type manhole 1.22m internal dia (at bottom) beyond 1.68 m to 2.29
181 m:
With F.P.S. bricks class designation 75 metre 20

14.12 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete
blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as
per standard design :
182
With 20x20 mm square bar each 400

Page-32 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

14.13 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per
IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as
23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112
mm space between protruded legs having 2 mm tread on top surface by ribbing or
chequering besides necessary and adequate anchoring projections on tail length on 138 mm
as per standard drawing and suitable to with stand the bend test and chemical resistance test
as per specifications and having manufacture's permanent identification mark to be visible
even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6
(1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per
design.

183 each 716

14.14 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape
184 and approved quality :
a L D- 2.5
Rectangular shape 600x450mm internal dimensions each 40
b EHD - 35
Circular shape 560 mm internal dia. each 98

14.15 Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation
75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C.
horizontal grating with frame complete as per standard design :
185
With F.P.S bricks each 162

14.16 Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks of class
designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand ) with pre-cast R.C.C. vertical
grating complete as per standard design :
186
With F.P.S. Bricks each 20

SUBHEAD XV - ALUMINIUM WORK

Page-33 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

15.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with
extruded built up standard tubular sections/ appropriate Z sections and other sections of
approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with
fixing clips, or with expansion hold fasteners including necessary filling up of gaps at
junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections
shall be smooth, rust free, straight, mitred and jointed mechanically wherever required
including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless
steel screws, all complete as per architectural drawings and the directions of Engineer-in-
charge. (Glazing and paneling to be paid for separately) :

187
a For fixed portion
Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868,
Minimum anodic coating of grade AC 15)
kg 68419
b For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and
making provision for fixing of fittings wherever required including the cost of PVC / neoprene
gasket required (Fittings shall be paid for separately).

Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868,
Minimum anodic coating of grade AC 15)
kg 44575

15.2 Providing and fixing double glazed hermetically sealed glazing in aluminum window,
ventilator partition and structural glazing etc with 6 mm thick toughened glass of approved
make Nano series Tropicana green product code KT 455 or Asahi Classic Green
(Specifications : Light transmission 27% to 30% Reflection external 17% to 20%, Reflection
Internal 12% to 33%, solar factor 0.20 to 0.21, Shading coefficient 0.23 to 0.24 and U vlaue
1.6 to 1.8) or equivalent both side having 12 mm air gap including providing EPDM gasket,
perforated aluminum spacers, desiccants, sillicon sealant (Both primary and secondary
sealant) etc (framework to be paid separately under relevant item)

188 sqm 4693

15.3 Providing and fixing double action hydraulic floor spring of approved brand and manufacture
IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors
and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc.
complete as per the direction of Engineer-in-charge.
189
With stainless steel cover plate each 59

Page-34 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

15.4 Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing
weather silicon sealant over backer rod of approved quality as per architectural drawings and
direction of Engineer-in-charge complete.
190
Upto 5 mm depth and 5 mm width. metre 13709

15.5 Providing and fixing aluminium tubular handle bar 32mm outer dia, 3.0 mm thick & 2100 mm
long with SS screws etc. complete as per direction of Engineer-in-charge.
191
Anodized (AC 15) aluminium tubular handle bar. each 187

15.6 Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors
including necessary cutting and making good etc. complete.
192 each 8

15.7 Providing and fixing non-anodised aluminium (anodised transparent or dyed to required
shade according to IS: 1868. Minimum anodic coating of grade AC 15) sub frame work for
windows and ventilators a with extruded built up standard tubular sections of approved make
conforming to IS: 733 and IS : 1285 fixed with rawl plugs and stainless steel screws etc.

193 kgm 15223

15.8 Providing fixing aluminium casement windows fastener of required length for aluminium
194 windows with necessary screws etc. complete.
Anodised ( AC 15 ) aluminium each 3472

15.9 Providing and fixing 10mm thick toughened glass frameless door including providing all
hardware fittings comprising of two pivot hinges one each at top and bottom, one lock, two
handles 300 mm long and making necessary holes and fixing of door complete as per the
directions of Engineer-in-Charge (All hardware fittings of stainless steel ozone make or
equivalent and toughened glass of Saint Gobain, Modiguard or equivalent)

195 sqm 173

15.10 Providing and fixing wire gauge shutter with aluminium frame of anodic coating AC-15, using
galvanised steel wire gauge of average width of apature 1.4mm with wire of dia 0.63mm for
doors, windows & clerestory windows including ISI marked stainless steel butt hinges of
anodic coating grade AC-15 with necessary screws completeas per drawing no.-08008A1-
S5-AD906
196 sqm 232

SUBHEAD XVI - WATER PROOFING

Page-35 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

16.1 Providing and laying integral cement based treatment for water proofing on horizontal surface
at all depth below ground level for under ground structures as directed by Engineer-in-
Charge and consisting of : i) Ist layer of 22mm to 25mm thick approved and specified rough
stone slab over a 25mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed
with water proofing compound conforming to IS:2645 in the recommended proportion over
the leveling course (leveling course to be paid separately). Joints sealed and grouted with
cement slurry mixed with water proofing compound. ii) 2nd layer of 25mm thick cement
mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended
proportions. iii) Finishing top with stone aggregate of 10mm to 12mm nominal size spreading
@ 8 cudm/sqm thoroughly embedded in the 2nd layer.

197
Using rough kota stone. sqm 1105

16.2 Providing and laying integral cement based treatment for water proofing on the vertical
surface by fixing specified stone slab 22 mm to 25mm thick with cement slurry mixed with
water proofing compound conforming to IS:2645 in recommended proportions with a gap of
20mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with
neat cement slurry mixed with water proofing compound and finishing the exterior of stone
slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20mm thick with neat cement
punning mixed with water proofing compound in recommended proportion complete at all
levels and as directed by Engineer-in-charge :

198
Using rough Kota stone sqm 1386

16.3 Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed
portions of W.C., kitchen and the like consisting of :
199
i) Ist course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing
compound conforming to IS 2645 in recommended proportions including rounding off junction
of vertical and horizontal surface.

ii) IInd course of 20mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water
proofing compound in recommended proportion including rounding off junction of vertical and
horizontal surface.

iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 Kg. per sqm of
area.

Page-36 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be
100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm.)
sqm 2527

16.4 Providing and Placing in position suitable PVC water stops conforming to IS:12200 for
construction/ expansion joints between two RCC members and fixed to the reinforcement
with binding wire before pouring concrete etc. complete :
200
Serrated with central bulb (225mm wide, 8-11mm thick). metre 1025.00

16.5 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry
mixed with water proofing cement compound consisting of applying: a) after surface
preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement
compound @ 0.253 kg/sqm. b) laying second layer of Fibre glass cloth when the first layer is
still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5
mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing
cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to
air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken
upto 30cm on parapet wall and tucked into groove in parapet all around. d) fourth and final
layer of brick tiling with cement mortar (which will be paid for separately For the purpose of
measurement the entire treated surface will be measured.

201 sqm 971.00

16.6 Providing and laying integral cement based water proofing treatment including preparation of
surface as required for treatment of roofs, balconies, terraces etc consisting of following
operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed
with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge
over the RCC slab including adjoining walls upto 300mm height including cleaning the
surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25
mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with
water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over
20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water
proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required
slope

202

Page-37 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

and treating similarly the adjoining walls upto 300 mm height including rounding of junctions
of walls and slabs c) After two days of proper curing applying a second coat of cement slurry
using 2.75kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645
and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick jointless
cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound
conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth
of approved quality in top layer of plaster and finally finishing the surface with trowel with neat
cement slurry and making pattern of 300x300 mm square 3mm deep. e) The whole terrace
so finished shall be flooded with water for a minimum period of two weeks for curing and for
final test. All above operations to be done in order and as directed and specified by the
Engineer-in-Charge :

With average thickness of 120mm and minimum thickness at khurra as 65 mm.


sqm 10382

SUBHEAD XVII - MISCELLANEOUS

17.1 Providing and fixing chicken wire mesh of approved make fixed with nails etc. at junction of sqm 1033.0
RCC & brickwork complete, before cement plastering.
203

17.2 Making cable trench of size 600 x 600 mm inside, including necessary excavation, base metre 80.0
concrete with 1:4:8 ( 1 Cement : 4 Fine Sand : 8 graded stone aggregates 40 mm size ), brick
work for walls in 1:6 ( 1 Cement : 6 Coarse Sand ) , cement concrete flooring on base with
1:2:4 finished with neat cement inside plastering 12 mm thick in 1:3 ( 1 cement : 3 coarse
sand ) finished with a floating coat of neat cement, grating at top with angle iron frame and
M.S flat as per drawing and painting with enamel paint over steel grating complete.

204

17.3 Supply and filling of stone boulders size 50 to 200 mm in re-charge pit. cum 90.0
205

17.4 Supply and filling pea gravel 10 to 50 mm for rain water harvesting pit. cum 170.0
206

17.5 Supply and filling coarse sand 1.50 to 2.0 size in rain water harvesting pit well. cum 142.0
207

Page-38 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

17.6 Supply and filling pea gravel size 2 mm to 3 mm in around bore well pipe Rain water cum 495.0
208 Harvesting / pit well.

17.7 Providing and filing brick bats of 40 mm to 100 mm size for rain water harvesting pit. cum 24.0
209

17.8 Supplying and lowering 200 mm outer dia CPVC pipe confiriming to I.S :4985 working metre 2000.0
pressure 6 kgm/ sqm with necessary fithings to make required length complete in re-charge
210 pit.

17.9 Supplying and lowering 200 outer dia slotted (with slot size 3 mm) pipe confirming to I.S:4985 metre 280.0
(working pressure 6 kgm / sqm) with necessary fittings to make required length complete in
211 bore hole.

17.10 Praviding and fixing housing clamp, pipe cap and plug at the bottom of 200mm outer dia each 40.0
CPVC pipe complete with all fittings as per direction of Engineer-in-charge.
212

17.11 Providing & laying S&S centrifugally cast (spun) iron pipes ( Class A ) confirming to IS-1536 :
( For Fire-Fighting work ) in ground i/c excavation and reflling the trench etc as required.
213
a 150mm dia metre 1350.0
b 100mm dia metre 200.0

17.12 Providing, fixing, testing & commissioning of single headed gun metal, ISI marked oblique each 53.0
pattern hydrant landing valve Type 'A' with 80mm dia flanged inlet & 63mm dia instanteous
type female outlet complete with gun metal cap and chain, twist release type lug and all
accessories as per (IS:5290-1983).
214

17.13 Providing, fixing, testing & commissioning of First Aid-Fire Hose Reel wall mounting swinging each 53.0
type complete with drum, bracket, stop valve 20mm dia, 30m long high pressure dunlop hose
reel tubing with gun metal shutoff nozzle conforming to IS:8090-1976 with 5mm orifice plate.
The hose reel shall be as per IS:884-1985.
215

17.14 Providing, fixing, testing & commissioning of Non-percolating flexible hose (RRL type 'A') ISI each 142.0
marked (IS:636) 63mm dia x 15m long complete with instantaneous type gun metal 63mm
dia ISI marked male and female couplings (IS:903) bound and riveted to hose pipe with
copper rivets and 1.5mm copper wire.
216
17.15 Providing, fixing, testing & commissioning of gun metal 63mm dia short branch with 20mm each 71.0
217 dia nozzle ISI marked (IS:903).

Page-39 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

17.16 Providing and fixing weather proof hose cabinet fabricated from 1.6mm MS sheet with front each 18.0
glass door and locking arrangement, suitable to accommodate all the necessary pipes,
accessories, fittings etc. as per drawing. The cabinet shall be painted with one coat of primer
and 2 more coats of synthetic enamel paint of approved shade and shall be suitably mounted
on concrete bases. 2 WAY FIRE BRIGADE INLET" etc. shall be painted in approved colour
and shade.

218

17.17 Providing and fixing door with frame for all internal fire hydrants fabricated from 20x20x3 mm each 53.0
and 40x20x3 mm hollow box sections mounted with 8 nos. of 100mm MS anodised butt hinge
on MS angle frame of 45x45x5 mm size with hold fasts fixed to wall with PCC (1:2:4) blocks
100x100x100 mm including 2 nos. allen key lock for locking along with padlock arrangement
& fully glazed with 4 mm thick float glass approved by local Fire Authority, stove enameled
fire red finish with "fire hose" written on front & to accommodate following: -
Gunmetal single headed hydrant valve - 1 No.
Fire hoses 63mm, 15M long with accessories -2 Nos.
Short branch - 1 No.
First Aid Hose Reel - 1 No.
Fire Extinguisher - 3 Nos.
Fireman's Axe - 1 No.
Pressure Gauge - 1 No.

219

17.18 Providing and fixing 150mm dia two-way fire brigade inlet connection consisting of 63mm each 13.0
instaneously male coupling and a check valve protected by cap scored with a chain glass
bore etc. complete with one 150mm dia sluice valve and 150mm dia non-return valve (To be
connnected to riser).
220

17.19 Providing, laying, jointing & testing of Mild Steel black pipe (IS:1239 / IS:3895) heavy class
including cutting, screwing, welding etc. complete with fitting viz. tees, elbows, bends,
flanges, reducers etc. including providing anti-corrosive treatment (coating and wrapping)
with 4mm thick tape and holiday test check as per IS:10221 complete as required.
Note : Pipes upto and 50mm dia shall be threaded joints, above 50mm shall be welded.

221
150 mm diameter pipes metre 350.0

Page-40 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

17.20 Providing and fixing butterfly valves, wafer end type class PN 1.6 as per IS:13095 - 1991 or
BS:5155, including necessary nuts, bolts, gaskets etc. complete (without gear box).
222
150 mm dia each 40.0

17.21 Providing, fixing, testing & commissioning of gunmetal alloy Gate Valve ISI marked screwed
223 type (type-2) as per IS:778-1987.
25 mm dia each 53.0

224 17.22 Providing and fixing dial type pressure gauge at hydrant station.
Dial diameter 100mm, caliberation 0-15 kg/cm2 each 26.0

17.23 Air-Cushion-Tank (Air Vessel) 250mm dia x 1.0m high with dished top, made of minimum each 20.0
6mm thick MS sheet pipe / plate complete with 25mm dia brass Air Valve (ball type) 25mm
dia stop valve, pressure gauge with brass stop cock, nipple, tees, elbows, pipe and all
accessories as required including fixing brackets.
225

17.24 Providing and fixing standard Fire Man's Axe with heavy insulated rubber conforming to each 59.0
226 IS:926.

17.25 Providing and fixing with bracket / supports etc. wall mounted fire extinguishers as per detail
227 below:
a ISI marked (IS:2878) portable fire extinguisher of 4.5 kg capacity carbon-dioxide type flat each 53.0
base including valve, discharge hose of not less than 10mm dia, 1m long & complete in all
respects including initial fill with CO2 gas conforming to IS:307-1966 filled to a filling ratio of
not more than 0.667 of not more than 0.667 and wall suspension bracket.

b 5 Kg ABC' stored pressure type Dry Chemical Powder (Mono-Ammonium Phosphate) fire each 53.0
extinguisher with fixing hangers, hose, brackets, screws to required size etc. complete as per
IS:2171.

Page-41 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

17.26 Providing and laying design mix cement concrete in roads, taxi tracks and runways having a cum 496.0
minimum works test beam flexural strength of 30 kg. per cm2. at 28 days using not less than
340 Kg. of cement per cum of finished concrete, coarse sand and graded stone aggregate of
40mm nominal size in appropriate proportions as per specified design criteria approved by
Engineer-in-charge mechanically vibrated using needle and surface vibrators including steel
form work with sturdy M. S. channel sections including curing and providing and filling
construction joints and dummy joints with approved joint filler and primer including rounding
of the edges and filling the grooves 10x25mm deep at top for construction joints and
10mmx50mm deep at top for dummy joints with joint sealing compound (conforming to grade
B of IS : 1834) including making necessary arrangements for expansion joints etc. all
complete.

228

17.27 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement cum 62.0
in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement:
3 coarse sand) including making joints with or without grooves (thickness of joints except at
sharp curve shall not to more than 5mm) including making drainage opening wherever
required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging
shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-
charge).

229

17.28 Providing and fixing weather proof hose cabinet fabricated from 1.6mm M.S. sheet with front
glass door and locking arrangement, suitable to accommodate all the necessary pipes,
accessories, fittings etc. as per drawing. The cabinet shall be painted with one coat of
primer and 2 more coats of synthetic enamel paint of approved shade and shall be suitably
mounted on concrete bases. The sign, " YARD HYDRANT", shall be painted in "CAPITAL
LETTERS in white synthetic paint.

230
a Size - 900x600x1500 high (For Yard Hydrant & 2 way suction collecting head) Each 18.0

Page-42 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

17.29 Supply, Installation, Testing & Commissioning of Mild Steel pipe (IS:1239 Part-I) heavy class
including cutting, threading, welding etc. bends, elbows reducers, clamps, hangers, flanges
etc. including cutting holes in brick or RCC walls/slabs and making good the same complete
including the cost of structural work for supports fabricated from standard sections of required
sizes and thickness e.g. galvanised M.S. rods, angles channels, slotted angle, etc., cutting to
sizes, drilling welding fixing to insert plates, including painting with one coat of primer and two
or more coats of synthetic enamel paint of approved make and shade including all steel work.
Note : Pipes upto and 50 mm dia shall be threaded joints, above 50mm shall be
welded joints.

231
a) 150mm dia. Metre 220.0
b) 100mm dia. Metre 1240.0
c) 80mm dia. Metre 1300.0
d) 65mm dia. Metre 730.0
e) 50mm dia. Metre 610.0
f) 40mm dia. Metre 440.0
g) 32mm dia. Metre 4500.0
h) 25mm dia. Metre 5650.0

17.30 Constructing masonary chamber 90x90x100 cm, inside with 75 class designation brick work Each 2.0
in cement mortar 1:5 (1 cement: 5 fine sand) for sluice valve, with C.I. Surface box 100mm
top diameter, 160mm bottom diameter and 180mm deep (inside) with chained lid and RCC
top slab 1:2:4 mix. ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal
size) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded
stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement
: 3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per
standard design With F.P.S. bricks.

232

17.31 Providing, fixing, testing and commissioning pressure switches suitable for operating with Each 27.0
hydrant and sprinkler systems for working pressure of 7 Kg/cm² pressure including
electrical wiring complete as required. The electrical wiring will be paid under separate
233 item.

17.32 Providing, fixing, testing and commissioning of 15mm dia. Quartzoid bulb type sprinkler with
temperature rating at 68°/79°C made out of forged brass and in nikel chrome finish.
234

a) Pendent /upright /conventional type Each 2650.0

Page-43 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

b) Side wall type Each 25.0

17.33 Providing, fixing, testing & commissioning of annunciater Panel for flow control switches
comprise of 6 zones(4 working and 2 spare), providing Audio/Visual Indication of actuation
of Automatic Sprinkler system for each zone complete as per specifications. The panel
should have interface for connection to complete controlled building management system.
The panel should have :
235
a) Fault indication for each zone.
b) indication of zone fire
c) Fire/fault hooter.
d) Alarm Panel for fire/fault.
e) Battery for emergency.
f) Battery charger.
g) Mains supply. Each 5.0

17.34 Providing and fixing 25 mm dia inspecting & testing assembly with gunmetal isolation valve, Each 6.0
gunmetal sight glass, bypass valve & connected to drain line complete (excluding the cost of
236 drain pipe).

17.35 Providing and fixing electrically operated flow indicating switches with threaded connection
for a minimum flow of 90 lpm for indicating water flow in sprinkler branch line on each floor
with necessary junction box installed in accessible place.
237
a On 150/100mm dia Pipe Each 27.0
17.36 Providing and laying in MS conduit PVC insulated ISI marked copper control cable in existing
conduit (IS:694) from individual flow switches on each floor to annunciation panel installed in
fire control room including sleeves cable clips, supports for horizontal runs etc. complete of
size
238
a 2 X 1.5MM Sq Meter 500.0

17.37 Providing and fixing with bracket/supports etc. wall mounted fire extinguishers as per detail
239 below :
a) ISI marked water CO2 Expelled gas type extinguishers 9 litres capacity with discharge Each 5.0
tube, metal cap, 60 grams carbon dioxide cartridge complete in all respects.

a) ISI marked water CO2 Expelled gas type extinguishers 9 litres capacity with discharge Each 5.0
tube, metal cap, 60 grams carbon dioxide cartridge complete in all respects.

Page-44 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

b) ISI marked (IS:2878) Portable fire Extinguisher, of 4.5 kg capacity Carbon-dioxide type flat Each 53.0
base including valve, discharge hose of not less than 10 mm dia. 1m long & complete in all
respects including initial fill with CO2 gas confirming to IS:307-1966 filled to a filling ratio of
not more than 0.667of not more than 0.667and wall suspension bracket.

c) 5 Kg ABC' stored pressure type Dry Chemical Powder (Mono-Ammonium Phosphate ) fire Each 53.0
extinguisher with fixing hangers, hose, brackets, screws to required size etc., complete as per
IS:2171

d) ISI marked (IS:10204) Portable Fire Extinguisher, Mech. Foam type capacity 9 ltrs with gun- Each 5.0
metal cap and nozzle and complete respects in all respects including initial fill and wall
suspension.

SUBHEAD XVIII - ACOUSTIC TREATMENT


18.1 Providing and fixing 12mm thick marine ply with commercial facing on both sides in backing sqm 674.0
for wall paneling of different types as per detail given in Architectural drawing and fixed to
existing MS tubular framework fixed / projected from the wall with necessary steel screws and
a priming coat with approved wood primer on unexposed surface at all heights / levels and
position of wall paneling as given in drawing. The item shall include the cost of making
opening in plywood for services like AC, grills, light fitting fixture, fire smoke detectors and
also include the cost of all material, scaffolding and T&P required and labour involved in all
the operation to execute the job as per drawing and direction of Engineer-in-charge
complete. (The MS tubular framework shall be paid separately).

240

18.2 Providing and fixing 20mm thick wood wool Acoustic Board of 400 kg/cum conforming to IS : sqm 620.0
3308 panels of required size and pattern the wood wool board shall be fixed to the MS
tubular frame already fixed / projected from the walls with necessary steel screws etc. at all
heights / levels and position detail given in the drawing. The item shall include the cost of
making opening in wood wool board for services like AC, grills, light fitting fixture, fire smoke
detectors and also include the cost of all material, scaffolding and T&P required and labour
involved in all the operation to execute the job as per drawing and direction of Engineer-in-
charge complete. (The MS tubular framework shall be paid separately).

241

Page-45 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

18.3 Providing and fixing 25mm thick 2nd class teak wood skirting 100mm wide and of approved sqm 70.0
pattern fixed to wall paneling at required level on floor with necessary screws, nails and rawl
plugs etc. and with a priming coat of approved wood primer on unexposed surface as per
drawing and direction of Engineer-in-charge complete.
242

18.4 Providing and fixing MS tubular frame work for different type of wall paneling at all heights as sqm 674.0
per details of wall paneling given in Architect drawing. The tubular frame work shall be made
of MS tube 40x40mm x18guage framed with welded joints and fixed / projected from wall and
held up in position by 40x40x5mm MS angle iron holdfast of varying length as per
requirement of Architect drawing showing details of different type of wall paneling. The MS
angle iron holdfast shall be fixed/embedded in wall with cement concrete 1:2:4 (1cement :
2coarse sand : 4graded stone aggregate 20mm nominal size) blocks of size 10x10x10cm
including cutting the necessary holes in brick / RCC wall and making good the same. The
MS angle iron holdfast shall be provided at 600x1200mm center to center(i.e. in vertical
direction @ 1200mm and center to center and in horizontal direction 600mm center to center
The MS tubular framework shall be fabricated so as to make a grid size of 600x600mm. The
frame work shall be fixed to hold fast with help of 10mm dia. bolt of required length by making
necessary holes in the frame work and holdfast angle etc. The MS tubular frame and MS
angle iron holdfast shall be painted with two coats of synthetic enamel paint of approved
brand and manufaturer over a priming coat of zinc chromate red oxide approved steel primer.
The frame work shall also include the cost of making opening for services of AC, light fitting
fixture and smoke detectors etc. by providing extra MS tube member if required, as per
requirement of drawing, details given and direction of Engineer-in-charge complete.(For
payment purpose wall area of the portion of hall where wall paneling with above framework
provided shall be measured only. For projection from wall paneling the soffit area of that
finished wall panel shall also be measured.

243
The rate shall include the cost of all material, scaffolding, T&P required and labour involved in
all the operation like cutting, fabrication, welding, drilling of holes, hoisting, fixing in position,
painting of framework and scaffolding etc. to execute the item as per drawing and direction of
Engineer-in-charge complete).

Page-46 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

18.5 Providing and laying wooden flooring with 75x25mm steam beach wood planks fixed with sqm 208.0
tounge & groove joints complete over the teak wood framework as detailed in the Architect
drawing no. SGA-2006(IIID)-SH-S6-AC008. The wooden plank shall be of 1500mm length,
fixed in required pattern as given in drawing with necessary screws of required size and
length. The wooden planks shall be fixed over two layers of 12mm thick marine ply fixed in
staggered joint pattern to support teak wood framework. The first layer of 12mm thick marine
ply shall be fixed to wooden frame work with necessary nails & screws and then second layer
of 12mm thick marine ply shall be pasted with suitable adhesive to first layer, laid with
staggered joints and fixed to first layer and framework with necessary nails and screws as
required. The support framework shall be of second class teak wood battens of required
sizes treated with two coats of fire retarder primer FR 881 undiluted @ 3.5sqm/litre. The
frame work batten of size 75x50mm shall be placed at 900 c/c in length wise direction and
teak wood battens of size 50x50mm shall be placed at 400mm c/c in shorter direction fixed
over longer direction wooden member by cutting 25mm deep rebate in longer side member.
The longer direction wooden frame batten shall be supported on 200x200mm LVL grout of
maximum varition 1:500 over which a 150x150mmx8mm thick ribbed Resistoflex (neoprene
Pads) (50 PSI grade) placed at 900x900mm c/c. Over the neoprene pad the main member
shall be held in position with two numbers 150mm long 50x50x6mm MS angle cleats fixed to
floor with two number 12.5mm dia. dash fastener of required length each on both angle cleat,
and shall be fixed to wooden frame with 2 numbers 10mm dia. bolts of required length.

The angle cleat shall be painted with 1 coat of zinc chromate red oxide steel primer. The
empty space between the wooden frame work shall be provided with 50mm thick resin
bonded fibre glass wool pads of density 24kg/cum. The frame work near the front as of stage
shall be provided as per detail given in above drawing. The steam beach wood / teak wood
panel shall be polished with polyurethene matfinish polish after making the base smooth with
necessary filling after sanding the wooden surface with use of orbital mechanical sanders
complete as per drawing and direction of Engineer-in-charge.

244

Page-47 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

18.6 Providing and fixing 145x50mm steam beach wood moulding fixed on the edge of stage with sqm 71.0
shorter direction wooden frame member and marine ply leaving a 5mm air gap as per detail
shown in the architect drawing no.SGA-2006(IIID)-SH-S6-AC008 the steam beach wood /
teak wood moulding surface shall be made smooth by sand papering and wood fillers and
finally finished with wax polishing in natural colour complete as per drawing and direction of
Engineer-in-charge.

245
Total Price of Section A

SECTION- B- Internal Electrical Installation


SH-I - WIRING
1 Point wiring in steel conduit, with modular type switch
Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 Sq.mm FR PVC
insulsted copper conductor single core cable in surface / recessed steel conduit, with modular
switch, modular plate, suitable GI box and earthing the point with 1.5 Sq.mm FR PVC
insulated copper conductor single core cable etc as required.
246
a Group C point 4780
b Wiring for Twin control light point with 1.5 Sq.mm FR PVC insulsted copper conductor single
core cable in surface / recessed steel conduit, with two way modular switch, modular plate,
suitable GI box and earthing the point with 1.5 Sq.mm FR PVC insulated copper conductor
single core cable etc as required.
point 116
2 Wiring for power plug with 2x4 Sq.mm FR PVC insulated copper conductor single core cable
in surface / recessed steel conduit alongwith 1 No. 4 Sq.mm FR PVC insulated copper
conductor single core cable for loop earthing as required.
247 meter 10554
3 Wiring for power plug with 4x4 Sq.mm FR PVC insulated copper conductor single core cable
in surface / recessed steel conduit along with 2 Nos. 4 Sq.mm FR PVC insulated copper
conductor single core cable for loop earthing as required.
248 meter 3550
4 Wiring for 20A Industrial power plug point with 2x6 Sq.mm FR PVC insulated copper
conductor single core cable in surface / recessed steel conduit along with 1 Nos. 6 Sq.mm
FR PVC insulated copper conductor single core cable for loop earthing as required.
249 meter 2220
5 Supply and fixing 20A, 240V, SPN industriral type, socket outlet, with 2 pole and earth, metal
enclosed plug top along with 20 amps 'C'series, SP, MCB, in sheet steel enclosure, on
surface or inrecess, with chained metal cover for the socket out let and complete with
connections, testing and commissioning etc. as required.
250 each 131

Page-48 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

6 Supply and fixing 30A, 240V, TPN industriral type, socket outlet, with 4 pole and earth, metal
enclosed plug top along with 30 amps 'C'series, TPMCB, in sheet steel enclosure, on surface
or inrecess, with chained metal cover for the socket out let and complete with connections,
testing and commissioning etc. as required.
251 each 95
7 Supplying and fixing GI box along with modular base , cover plate ,1 no.6A modular switch &
2 nos. 6A sockets in recess etc as required.for computer terminal points.
252 each 512
8 Supplying and fixing following size/ modules, GI box along with modular base & cover plate
for modular switches in recess etc as required.
253
a 2 Module (75mm x 75mm) each 53
b 4 Module (125mm x 75mm) (Light Plug Point) each 1329
c 6 Module (200mm x 75mm) (Power Plug Point) each 1323
9 Supplying and fixing following modular switch/ socket on the existing modular plate & switch
box including conections but excluding modular plate etc. as required.
254
a 5/6 amps switch and 3 pin 5/6 amp socket outlet each 1329
b 15/16 amp switch and 6 pin 15/16 amp socket outlet each 1323
10 Circuit / submain /Light plug wiring in steel conduit:
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC
insulated copper conductor, single core cable in surface / recessed steel conduit as required.
255
a 2 x 1.5 Sq.mm + 1 x 1.5 Sq.mm earth wire for (Light plug) meter 12400
b 2 x 2.5 Sq.mm + 1 x 2.5 Sq.mm earth wire(Circuit wiring) meter 4280
c 4 x 2.5 Sq.mm + 2 x 2.5 Sq.mm earth wire(Circuit wiring) meter 1510
d 4 x 6 Sq.mm + 2 x 6 Sq.mm earth wire (Submain DB with timer /3 phase power point wiring)
meter 2700
e 4 x 16 Sq.mm + 2 x 16 Sq.mm earth wire (Submain wiring ) meter 2200
11 Supplying, installing, testing and commisioning of factory made ,painted powder coated paint
DLP Almunium trunking of Size 105x 50 mm on wall complete with fixing screws,
interconnections,joints, earthing etc. as required.
256 meter 850
12 Supplying, and fixing of factory made Almunium trunking cover of 85 mm width complete
257 with fixing screws etc. as required. meter 850

Sub-Head - II - Main Board, DB's & Cables

Page-49 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

1 S/F rising main :


Supplying ,installing on wall ,testing ,commissioning of following capacity rising main with
metal clad enclosure,wall straps , fully PVC insulated TPN aluminium busbars in convenient
sections and suitable for 400/650 volts,3phase,4 wire ,50 HZ,A.C.supply with extension
joints, fire proof barriers,expansions joints ,thrust pads including jointing ,and earthing with 2
runs of galvanised iron strips etc. as required .(Rising mains confirming to IS 8623,TEC 439 ).

258
a 400 amps (SC rating for 1 sec.-25 KA) metre 55
b 200 amps (SC rating for 1 sec.-20 KA) metre 55
2 S/F TPN tap-off box with TPN MCCB:

Supplying, installing, testing and commisioning of TPN tap off box of following capacity on
existing rising mains and complete with TPN MCCB of the following rating, interconnection,
earthing etc. as required.
259
a 100 amps TPN each 20
b 200 amps TPN each 20
3 S/F adopter box with cable end box gland:

Supplying, installing, testing and commisioning of adopter box of following capacity on


existing rising mains and complete with stand, cable end box, brass compression gland,
interconnection, earthing etc. as required.
260
a 400 amps TPN each 4
b 200 amps TPN each 4

261 4 S/F MCCB in cubicle panel board:/Rising Main


Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel
board including drilling holes in cubicle panel, making connection, etc. as required.

a 400 amps, 35 KA each 4


b 200 amps, 35 KA each 24
c 100 amps, 16 KA each 20
d 63/100 amps, 10 KA each 21

5 Providing and fixing on surface 63/100 amps rating and 16 KA breaking capacity MCCB in
MS sheet enclosure complete with supporting angle iron frame including drilling holes
,making connection, etc. as required.
262 each 19

Page-50 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

6 Fabrication, Supply, installation, testing and commissioning of wall/floor maounted cubicle


panels out of 1.6 mm thick CRCA MS sheet steel. All incomngs/ outgoings shall be arranged
in suitable size compartments with locking arrangement for each compartments, including
interconnection with 1100 V grade PVC insulated copper conductor, bus bar, labelling,
earthing, brass compression glands for incoming and outgoing cables, powder coted painting
etc. complete as required.

263
a MDB (Small Animal)
Incoming :
800A, 4P ACB (35 KA) - 1 No.
800 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
400 A TPN MCCB - 35 KA - 6 No.
Instruments
1 set of (0-500V) Digital Voltmete with protection fuses and selector switch.

1 set of (0-800A) Digital Ammeter with necessary CT's and selector switch.
1 set of R.Y.B indicating lamps.(LED type)
set 1
b MDB-P (THSTI)
Incoming :
800A, 4P ACB (35 KA) - 1 No.
800 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
400 A TPN MCCB - 35 KA - 3 No.
200 A TPN MCCB - 35 KA - 3 No.
100 A TPN MCCB - 25 KA - 1 No.
Instruments
1 set of (0-500V) Digital Voltmete with protection fuses and selector switch.

1 set of (0-800A) Digital Ammeter with necessary CT's and selector switch.
1 set of R.Y.B indicating lamps.(LED type)
set 1
c MDB-L (THSTI)
Incoming :
400A, TPN MCCB (35 KA) - 1 No.
400 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:

Page-51 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

200 A TPN MCCB - 35 KA - 3 No.


100 A TPN MCCB - 25 KA - 2 No.
Instruments
1 set of (0-500V) Digital Voltmete with protection fuses and selector switch.

1 set of (0-400A) Digital Ammeter with necessary CT's and selector switch.
1 set of R.Y.B indicating lamps.(LED type)
set 3
d (SDB -2) (Primate)
Incoming :
400A, TPN MCCB (35 KA) - 1 No.
400 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
125 A TPN MCCB - 25 KA - 3 No.
100 A TPN MCCB - 25 KA - 1 No.
63 A TPN MCCB - 16 KA - 5 No.
Instruments
1 set of (0-500V) Digital Voltmete with protection fuses and selector switch.

1 set of (0-400A) Digital Ammeter with necessary CT's and selector switch.
1 set of R.Y.B indicating lamps.(LED type)
set 2
e MDB P (Library)
Incoming :
630A, TPN MCCB (35 KA) - 1 No.
650 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
315 A TPN MCCB - 35 KA - 1 No.
125 A TPN MCCB - 35 KA - 4 No.
63 A TPN MCCB - 16 KA - 4 No.
Instruments
1 set of (0-500V) Digital Voltmete with protection fuses and selector switch.

1 set of (0-800A) Digital Ammeter with necessary CT's and selector switch.
1 set of R.Y.B indicating lamps.(LED type)
set 1
f MDB-P ( RCB)
Incoming :
800A, 4P ACB - 1 No.

Page-52 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

800 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
400 A TPN MCCB - 35 KA - 3 No.
200 A TPN MCCB - 35 KA - 3 No.
100 A TPN MCCB - 25 KA - 1 No.
Instruments
1 set of (0-500V) Digital Voltmete with protection fuses and selector switch.

1 set of (0-800A) Digital Ammeter with necessary CT's and selector switch.
1 set of R.Y.B indicating lamps.(LED type)
set 1
g MDB-L (Library)
Incoming :
400A 4P COS - 1 No.
315A, TPN MCCB (35 KA) - 1 No.
400 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
160 A TPN MCCB - 35 KA - 1 No.
63A TPN (16KA) MCCB.- 4 Nos.
Instruments
1 set of (0-500V) Digital Voltmete with protection fuses and selector switch.

1 set of (0-400A) Digital Ammeter with necessary CT's and selector switch.
1 set of R.Y.B indicating lamps.(LED type)
set 1
h MDB-L ( RCB)
Incoming :
400A, TPN MCCB (35 KA) - 1 No.
400 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
200 A TPN MCCB - 35 KA - 3 No.
100 A TPN MCCB - 25 KA - 2 No.
Instruments
1 set of (0-500V) Digital Voltmete with protection fuses and selector switch.

1 set of (0-400A) Digital Ammeter with necessary CT's and selector switch.
1 set of R.Y.B indicating lamps.(LED type)
set 1
i Autoclave Panel

Page-53 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

Incoming :
400A, TPN MCCB (35 KA) - 1 No.
450 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
100 A TPN MCCB - 25 KA - 6 No.
Instruments
1 set of (0-500V) Digital Voltmete with protection fuses and selector switch.

1 set of (0-400A) Digital Ammeter with necessary CT's and selector switch.
1 set of R.Y.B indicating lamps.(LED type)
set 1

7 Fabrication, installation, testing and commissioning of wall/floor maounted cubicle panels out
of 1.6 mm thick CRCA MS sheet steel, all incomngs/ outgoings shall be arranged in suitable
size compartments, locking arrangement for each compartments, including interconnection
with 1100 V grade PVC insulated copper conductor bus bar labelling, earthing, brass
compression glands for incoming and outgoing cables.

264
a (FDB-1 ) (Small Animal)
Incoming :
125 A TPN MCCB - 25 KA - 1Nos.
150 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
63A TPN (16KA) MCCB.- 4 Nos.
Indication
1 set of R.Y.B indicating lamps.(LED type) set 5
b (FDB-2 ) (SA, PR & ESS)
Incoming :
125 A TPN MCCB - 35 KA - 1Nos.
150 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
63A TPN (16KA) MCCB- 4 Nos.
100A TPN (25 KA) MCCB - 1 Nos.
Indication
1 set of R.Y.B indicating lamps.(LED type) set 6
c (FDB-L ) for THSTI
Incoming :

Page-54 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

100 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
40A TPN MCB- 4 Nos.
1 set of R.Y.B indicating lamps.(LED type) set 10
d (FDB-P1) for THSTI
Incoming :
200 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
63A TPN (16KA) MCCB- 3 Nos.
100A TPN (25 KA) MCCB - 1 Nos.
1 set of R.Y.B indicating lamps.(LED type) set 2
e (FDB-P2) for THSTI
Incoming :
200 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
63A TPN (16KA) MCCB- 4 Nos.
100A TPN (25 KA) MCCB - 1 Nos.
1 set of R.Y.B indicating lamps.(LED type) set 2
f (FDB-P3) for THSTI
Incoming :
200 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
63A TPN (16KA) MCCB- 6 Nos.
100A TPN (25 KA) MCCB - 1 Nos.
1 set of R.Y.B indicating lamps.(LED type) set 6
g (FDBP-1,2,3,4,7 ) of RCB
Incoming :
125 A TPN MCCB - 25 KA - 1Nos.
150 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
63A TPN (16KA) MCCB.- 6 Nos.
Indication
1 set of R.Y.B indicating lamps.(LED type) set 5
h (FDBP-8,9 ) of RCB
Incoming :
125 A TPN MCCB - 25 KA - 1Nos.

Page-55 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

150 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
63A TPN (16KA) MCCB.- 7 Nos.
Indication
1 set of R.Y.B indicating lamps.(LED type) set 2
i (FDBP-6 ) of RCB
Incoming :
125 A TPN MCCB - 25 KA - 1Nos.
150 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
63A TPN (16KA) MCCB.- 3 Nos.
Indication
1 set of R.Y.B indicating lamps.(LED type) set 1
j (FDBP-5,10 ) of RCB
Incoming :
125 A TPN MCCB - 35 KA - 1Nos.
150 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
63A TPN (16KA) MCCB- 4 Nos.
100A TPN (25 KA) MCCB - 1 Nos.
Indication
1 set of R.Y.B indicating lamps.(LED type) set 2
k (FDB-L ) for RCB
Incoming :
100 A TPN MCCB - 35 KA - 1Nos.
100 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
40A TPN MCB- 4 Nos.
1 set of R.Y.B indicating lamps.(LED type) set 10
l AHU Panel for RCB
Incoming :
200 A TPN MCCB - 35 KA - 1Nos.
200 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
63A TPN (16KA) MCCB- 7 Nos.
1 set of R.Y.B indicating lamps.(LED type) set 2
m AHU Panel for Library

Page-56 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

Incoming :
125 A TPN MCCB - 35 KA - 1Nos.
150 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
63A TPN (16KA) MCCB- 4 Nos.
1 set of R.Y.B indicating lamps.(LED type) set 2
n (FDB-P1) for library
Incoming :
125A TPN (25 KA) MCCB - 1 Nos.
150 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
63A TPN (16KA) MCCB- 3 Nos.
100A TPN (25 KA) MCCB - 1 Nos.
1 set of R.Y.B indicating lamps.(LED type) set 1
o (FDB-P2) for library
Incoming :
160A TPN (25 KA) MCCB - 1 Nos.
200 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
63A TPN (16KA) MCCB- 3 Nos.
100A TPN (25 KA) MCCB - 1 Nos.
1 set of R.Y.B indicating lamps.(LED type) set 1
p Lift Panel (SA, PR, THS & RCB)
Incoming :
100 A 4P Changeover Switch - 1Nos.
100 A TPN MCCB - 25 KA - 1Nos.
100 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
63A TPN MCCB - 2 Nos.
32/40A DP MCB - 2 Nos.
Indication
1 set of R.Y.B indicating lamps.(LED type) set 6
q AHU Panel (1&2) for SA
Incoming :
125 A TPN MCCB - 25 KA - 1Nos.
125 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:

Page-57 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

63A TPN MCB - 2 KA - 4 Nos.


Indication
1 set of R.Y.B indicating lamps.(LED type) set 2
r AHU Panel (1&2) for THSTI
Incoming :
200 A TPN MCCB - 35 KA - 1Nos.
200 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
100A TPN MCB - 25 KA - 1 No.
63A TPN MCB - 16 KA - 5 Nos.
Indication
1 set of R.Y.B indicating lamps.(LED type) set 2

8 SITC of Timer controlled prewired TP MCB DB:


Supply,Installation,Testing and comissioning of 4 way, three pole and neutral, prewired, sheet
steel, MCB distribution board, 415 volts, on surface / recess, complete with loose wire box,
terminal blocks, duly prewired with suitable size FR PVC insulated copper conductor up to
terminal blocks, tinned copper busbar, neutral link, earth bar, din bar, detachable gland plate,
interconnections, phosphatized and powder painted including earthing etc. as required ,
including contractor and timer switch on incoming MCB for automatic control (daily on/off ) of
lighting circuits.The DB with timer suitable to daily switch ON and switch OFF the ckts at a
predetermined times shall be with following accessories complete as required :

265
30 A TP Contractor of coil voltage 240 V
Time Switch
40 TPN MCB Isolator -1 No.
32 A DP RCCB - 3 No.
20 A SP MCB - 12 Nos. each 6

Page-58 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

9 S/F vertical type TP MCB DB:


Supplying,installation ,testing and comissioning of surface/ recess mounting,vertical type, 415
volts, prewired ,TPN MCB distribution board of sheet steel ,dust protected ,duly phosphatized
and powder painted ,inclusive of 200 amps tinned copper bus bar ,common neutral link,earth
bar, din bar for mounting MCB's,detachable gland /knock out plate and with built in loose wire
box and superior make terminal connector for all incoming and outgoiong circuits ,duly
prewired with adequate size of FR PVC insulated copper conductors upto the terminal
connector /neutral link and ready for installation of ways, and busbar of following ways (but
without MCB's and MCCB's) as required. (For Labs)

266
8 way each 32

10 S/F prewired TP MCB DB:


Supplying and fixing following way, three pole and neutral, prewired, sheet steel, MCB
distribution board, 415 volts, on surface / recess, complete with loose wire box, terminal
blocks, duly prewired with suitable size FR PVC insulated copper conductor up to terminal
blocks, tinned copper busbar, neutral link, earth bar, din bar, detachable gland plate,
interconnections, phosphatized and powder painted including earthing etc. as required. (But
without MCB / RCCB / Isolator).

267
a 4 way (4 + 12), Double door each 57
b 6 way (4 + 18), Double door each 51
c 8 way (4 + 24), Double door each 18
11 S/F TP MCB Isolator :
Supplying and fixing following rating, four pole, 415 volts, Isolator in the existing MCB DB
complete with connections, testing and commissioning etc. as required.
268
a 40 amps each 42
b 63 amps each 88
c 100 amps each 28

12 S/F DP RCCB :
Supplying and fixing following rating, Double pole, 415 volts,Residual curent circuit breaker
(RCCB) , having a sensitivity current upto 300 milliamperes in the existing MCB DB complete
with connection, testing and commissoning etc.as required.
269
a 40 amps each 157
b 63 amps each 239

Page-59 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

13 Supplying and fixing 5 amps to 32 amps rating, 240 volts, 'B' series, miniature circuit breaker
suitable for lighting and other loads of following poles in the existing MCB DB complete with
connections, testing and commissioning etc. as required.
270
Single pole each 2315

14 Supplying and fixing 20/32 amps rating, 415 volts, 'C' series, miniature circuit breaker suitable
for lighting and other loads of following poles in the existing MCB DB complete with
connections, testing and commissioning etc. as required.
271
20/32 A TP MCB each 93

15 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as
272 required. each 181

16 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at
least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in single
red colour on front side as required.
273 each 27

17 Supplying and laying of HD PVC pipe of following size for road/ floor crossing of cables at a
depth of 600mm below ground level including sealing of joints with solvent and sealing of
ends etc. complete as required.
274
100mm dia PVC pipe metre 190

18 Supply of following sizes of 1.1 KV grade single core/multicore aluminium conductor XLPE
insulated and PVC sheathed armoured cable conforming to IS 1554 (Part-I) 1988.
275
a 3.5 Core, 300 sq.mm. XLPE Aluminium Cable RM 200
b 3.5 Core, 185 sq.mm. XLPE Aluminium Cable RM 1120
c 3.5 Core, 120 sq.mm. XLPE Aluminium Cable RM 170
d 3.5 Core, 95 sq.mm. XLPE Aluminium Cable RM 260
e 3.5 Core, 50 sq.mm. XLPE Aluminium Cable RM 160
f 3.5 Core, 35 sq.mm. XLPE Aluminium Cable RM 250
g 4 Core, 25 sq.mm. XLPE Aluminium Cable RM 50
h 4 Core, 16 sq.mm. XLPE Aluminium Cable RM 550
Note: Actual length of cable should be verified at the site prior to the installation.
Incoming cables from ESS are not included in the scope of IEI.

Page-60 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

19 Laying and fixing of one number PVC/XLPE insulated and PVC sheathed Aluminium
conductor 3.5/4 core power cable of following sizes of 1.1 KV grade, direct in ground
including excavation, sand cushioning, protective brick covering etc. or fixing on wall/ ceiling
with MS clamps, nut bolts etc. as required.
276
a exceeding 25 sq.mm. But not exceeding 120 sq. mm. RM 1120
b exceeding 120 sq.mm. But not exceeding 400 sq. mm. RM 860
20 Supply and making cable end termination with brass compression glands and crimped
aluminium lugs following sizes of PVC sheathed / XLPE aluminium conductor cable of 1.1 KV
grade of the following sizes as required.
277
a 3.5 Core, 300 sq.mm. XLPE Aluminium Cable set 6
b 3.5 Core, 185 sq.mm. XLPE Aluminium Cable set 30
c 3.5 Core, 120 sq.mm. XLPE Aluminium Cable set 6
d 3.5 Core, 95 sq.mm. XLPE Aluminium Cable set 66
e 3.5 Core, 50 sq.mm. XLPE Aluminium Cable set 42
f 3.5 Core, 35 sq.mm. XLPE Aluminium Cable set 18
g 4 Core, 25 sq.mm. XLPE Aluminium Cable set 8
h 4 Core, 16 sq.mm. XLPE Aluminium Cable set 48

Sub Head - III Conduiting / Wiring for Telephone/LAN/TV


1 Supplying and fixing of following sizes of PVC conduit alongwith the accesories in
surface/recess including cutting the wall and making good the same in case of recessed
278 conduit as required.
a 20 mm metre 1800
b 25 mm metre 4200
c 32 mm metre 1200
2 Supply & Installation of 150x150x40 mm. deep 16 SWG factory fabricated MS junction box of
best quality complete with accessories, painting etc.,to be fixed in floor or on wall / ceiling
complete as required.
279 each 28
3 Supplying and fixing metal box of following sizes (nominal size) on surface or recess with
suitable size of phenolic laminated sheet cover in front including painting etc. required.
280
a 200x150x60 each 15
b 200x250x75 each 15
Telephone Wiring
4 Supplying and fixing of RJ-11 telephone socket outlet with GI sheet box and modular cover
281 plate complete as required:-
Single RJ-11 in One Plate. each 355

Page-61 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

5 Supplying & drawing following pair, 0.5 sq. mm. FR PVC insulated copper conductor,
unarmoured telephone cable in the existing surface/ recessed steel / PVC conduit as
282 required:-
2 Pair metre 9000
6 Supplying & laying/fixing of following pair, 0.5 sq. mm. FR PVC insulated copper conductor,
armoured telephone cable in the existing surface/ recessed steel / PVC conduit as required:-
283
a 10 Pair metre 250
b 20 Pair metre 200
c 50 Pair metre 100
7 Supply and installation of KRONE connector type main telephone tag block of following
sizes in sheet metal enclosure of suitable dimensions fabricated out of 16 SWG sheet steel
with castle key lock, hinged type cover including termination of telephone cables, making
connections, painting of box etc. complete as required:-
284
a 10 Pairs each 11
b 20 Pairs each 14
c 50 Pairs each 7
Computer System Wiring
8 Supply, drawing, testing & commissioning of 4 Pair CAT-6 Non-Plenum UTP cable of 24
AWG solid copper conductors complete as required.
285 metre 13410
9 Supplying, installation, testing & commissioning of RJ-45 Flush mounted information outlets
wired according to T 5688 standard with a surface mount box complete as required:-
286
Single Outlet in one Face plate each 533
Note: Computer system wiring shall include numbering and termination and testing of
cables at both the ends.( computer outlet points )

Sub-Head - IV - Installation of Light fittings, fans and fixtures


1 Installation, testing and commissioning of prewired, flourescent fittings / compact flourescent
fittings of all types, complete with all accessories and tube etc. directly on ceiling/wall/ False
ceiling, including connections with 1.5 sq.mm. PVC insulated, copper conductor, single core
cable etc. as required.
287 each 3664
2 Installation, testing and commissioning of prewired, fluorescent fittings of all types, complete
with all accessories and tubes etc., including supplying and fixing ball and socket 2 nos.
down rods of 20 mm. dia. x 1.6 mm. thick steel conduit upto 30 cm. length, painting and
wiring the down rods and connections with 1.5 sq.mm. PVC insulated, copper conductor,
single core cable as required.
288 each 543

Page-62 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

3 Installation of exhaust fan upto 450 mm sweep in the existing opening, including making the
hole to suit the size of the above fan, making good the damage, connections, testing,
commissioning etc. as required.
289 each 121
4 Installation, testing and commissioning of ceiling fan including wiring the down rods of
standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated, copper conductor, single
core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc.
as required.
290 each 563
5 Fixing louvers / shutters for exhaust fan:
Extra for fixing the louvers / shutters complete with frame for a exhaust fan of all sizes.
291 each 121

Sub Head - V - Supply of Light Fitting/Fans /Luminaries and Fixtures


1 Supplying of following lighting fixtures complete with special electronics low loss ballast/
lumilux tube/ lamp/ condenser/ starter /louvers/ reflector/cover etc. complete as required:-
292
a Surface Mounted Strip type flourscent fitting suitable for and with 1 no. 28 watt T5 lamps.
Philips / Instapower / Wipro / Osram as approved.
each 259
b Surface / recessed Mounted decorative flourscent fitting suitable for and with 2 nos 28 watt
T5 lamps.
Philips / Instapower / Wipro / Osram as approved. each 2170
c Mirror light fitting with 1 x 18 watt CFL lamp of Philips make Cat no. FMS 200/111 or
equivalent as approved. each 50
d Surface mounted 11 watt LED lamp Fitting.
Philips / Instapower / Wipro / Osram as approved. each 288
e Recessed mounted 9 watt Mirror Optic LED lamp fitting with lamp.
Philips / Instapower / Wipro / Osram as approved. each 741
f Surface / wall mounted Bulkhead luminarires 5 watt LED lamp. Philips / Instapower /
Wipro / Osram as approved. each 79
g Recessed mounted 25 watt Mirror Optic LED lamp fitting with lamp.
Philips / Instapower / Wipro / Osram as approved. each 225
h Surface mounted wall /ceiling light luminaire with 1x11 watt LED complete as required.
Philips / Instapower / Wipro / Osram as
approved. each 21
i Brick light luminaire 1X13 W PL lamp fitting suitable for 1 No. 13 W PL lamp with frosted
glass cover /acrylic diffuser of blue colour Cat .No. Decon 54SX02 or equivalent as
approved. each 35
j Indoor surface mounted down light 18 watt LED lamp fitting with cover.
Phillips / Instapower / Wipro / Osram as approved.
each 65

Page-63 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

k Surface Mounted Strip type flourscent fitting suitable for and with 1 no.28 watt TL5 lamps .
Philips TMS 122/128 EHF with 1x28 TL5 lamp / Instapone / Wipro / Osram as approved.

each 182
m 65W Decorative CFL open highbay fitting with 65 W PL Lamp
each 40
n Philips
RecessedHPK 205 1XPLEH
Mounted 65W
fitting 35 wattor equivalent
LED as approved.
downlighter.
Philips / Instapower / Wipro / Osram as approved. each 40
o Supply, installation, testing & commissioning of self contained 3 watt LED Sign Board
minimum five hour reserve) double sided emergency signalling unit for flag/suspension
mounting with suspension kit & having "EXIT" or "FIRE EXTINGUISHER" or "FIRE HOSE
REEL" as per actual mounting location complete with connections as required. Philips /
Instapone / Wipro / Osram as approved.

each 12
2 Supplying of Ceiling fans suitable for 230 Volt, 50 Hz, Single phase, A.C. supply and
complete without speed regulator all standard accessories such as blades & capacitor etc.
Makes CG/Usha/Havels
293
a 3 Blade-1200 mm Ceiling fan each 417
b 3 Blade-1400 mm Ceiling fan each 433
3 Supplying and fixing stepped type elctronic fan regulator on the existing modular plate switch
box excluding modular plate as required.
294 each 840
4 Supplying of following sizes of Exhaust Fans suitable for 230 Volt, 50 Hz, Single phase, A.C.
supply and complete with all standard accessories such as motors, blades & louvers, shutters
etc. in the existing opening i/c. making the hole to suit the sizes of the above fan & making
good the damages and connection with 1.5 Sq.mm PVC insulated FRLS copper conductor
wires from the point outlet to the fan as required. Makes GEC/Havels/Usha LX

295
a 300 mm dia. each 119
b 450 mm dia each 33
5 Supply, Installation,Testing and comissioning of 30 watt LED street lighting luminaries
complete as required.
296 Phillips / Instapone / Wipro / Osram as approved. each 35
6 supplying and fixing of 40 mm dia, 1 mtr. Long GI pipe Bracket , MS clamps ,nuts, bolts
,painting wiring etc. complete as required for installation of street light luminaire on the
297 building. each 20
7 Supply , Installation and commissioning of 3000VA Sine Wave Inverter complete with 80 AH
maintenance free inverter batteries including all accessories ,wiring, connections etc as
298 required. each 1

Page-64 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

8 Supply, Installation,Testing and comissioning of Blower type 2 KW Heat convector (room


heater) with two elements of 1 KW each, speed regulator and thermostat for temperature
control complete with all accessories as required. Make: Usha Lexus/Bajaj
299 each 27
9 Supply, Installation , testing and comissioning of Revoloving Type 600 mm air circulator fan
wall mounting with speed regulator.
300 Make : Almonard as approved. each 18
Sub-Head - VI - Earthing
1 Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm.thick including accessories, and
providing masonary enclosure with cover plate having locking arrangement and watering pipe
etc. (but without charcoal and salt) as required.
301 set 34
2 Extra for using salt & charcoal for G.I. plate earth electrode as required.
302 set 39
3 Providing and fixing 25mm x 5mm GI strip in 40 mm dia. G.I. Pipe from earth electrode as
303 required. metre 265
4 Providing and fixing 25 mm x 5mm GI strip on surface or in recess for connections etc. as
304 required. metre 340
5 Earthing with Copper earth plate 600 mm x 600 mm x 3 mm.thick including accessories,
and providing masonary enclosure with cover plate having locking arrangement and watering
pipe etc. (but without charcoal and salt) as required.
305 set 5
6 Providing and fixing 25mm x 5mm Copper strip in 40 mm dia. G.I. Pipe from earth electrode
306 as required. metre 55
7 Providing and fixing 25 mm x 5mm Copper strip on surface or in recess for connections etc.
307 as required. metre 85
8 Providing and fixing of lighting conductor finial, made of 25mm dia. 300mm long, G.I. tube,
haviing single prong at top, with 85mm dia. 6mm thick G.I. base plate including holes etc.
308 complete as required. mtr. 8
9 Providing and fixing G.I. tape 20mm x 3mm thick on parapet of surface of wall for lighting
conductor complete as required. (For Horizontal Run).
309 mtr. 1700
10 Providing and fixing G.I. tape 20mm x 3mm thick on parapet of surface of wall for lighting
conductor complete as required. (For Vertical Run).
310 each 430
11 Providing and fixing testing joint, made of 20mm x 3mm thick G.I. strip, 125mm long, with
4Nos. Of G.I. bolt, nuts, check nuts & spring washers etc. complete as required.
311 each 16

Sub-Head - VII - Fire Alarm System (Automatic Addressable)

Page-65 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

1 Supply fixing testing and commissioning of Analouge addressable photothermal type


photodetector type detector with mounting based LED with address switch to programmed
the detectors from 01-159 ,complete as required.The detector should be capable of
adjusting ,its sensitivity as per the change in the enviroment.(UL LISTED)

312
a) Ionisation type Smoke detector each 505
b) Ionisation type Heat detector each 215
2 Supplying fixing testing and commissioning of Addressable control modules for hooters,
AHU's , WFD Smoke detector, Leak detector, pressurising fans etc. .(UL LISTED)
313 each 115
3 Supplying fixing testing and commissioning of Addressable Manual call stations .(UL LISTED)
314 each 63
4 Supplying fixing testing and commissioning of Addressable sounders/electronics hooters
cum speakers as required for the fire detection and alarm system to be fixed at appropriate
height on wall on surface or in recess as required.
315 each 63
5 Supply,installation,testing aand commissioning of Microprocessor based 8 loop expandable
Analauge addressable type fire alarm control panel without any display.The panel should be
equipped of 4 loops with loop capacity to take 99 analauge addressable devices in one loop
and 198 total devices capacity,1000 event history, Four access levels,capable of taking
Flash scan devices flash EPROM sufficient numbers of programmable relay controls for
controlling AHU's ,pressurisation fans,ventlation fans at fire pump room,monitoring of fire
sprinkler and fire hydrant pump,240 V AC power supply ,automatic battery charger & inbuilt
24V sealed VRLA maintainance free batteries sufficient for 24 hours normal working and then
be capable of operating the system for 2 hours during an emergency conditions as required.

316 each 5
6 Supply Installation Testing & Commissioning of complete fire deduction and alarm system
complete as required including approval from local fire authorities.
317 Job 6
7 Supplying and laying/fixing of following sizes of 1.1 KV grade PVC insulated sheathed and
armoured Copper conductor control cable direct in ground including excavation, sand
cushing break covering and refilling the trench directly on wall/ceiling with MS clamps, nut
bolts etc. as required.
318
a) 2.5 sqmm / 4 core cable metre 610
b) 2.5 sqmm / 8 core cable metre 850
8 Supplying, drawing, connecting , testing of following single core PVC insulated FRLS copper
wires in existing conduit for Fire alarm System.
319

Page-66 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

a) 2x1.5 sqmm metre 2850


b) 3x1.5 sqmm metre 1600
c) 4x1.5 sqmm metre 900
9 Supplying and fixing of following sizes of steel conduit along with accessories in
surface/recess including painting in case of surface conduit, or cutting the wall and making
good the same in case of recessed conduit as required.
320
a) 20 mm dia metre 1450
b) 25 mm dia metre 2200
c) 32 mm dia metre 800
10 Supply, installation, testing & commissioning of self contained 2W LED (minimum one hour
reserve) double sided emergency signage unit for ceiling / wall mounting & having "EXIT" or
"FIRE EXTINGUISHER" or "FIRE HOSE REEL" as per actual mounting location complete
with connections as required
321 each 70
Total Price of Section B
SECTION- C- EXTERNAL ELECTRICAL INSTALLATION
SUB HEAD A: SUB STATION EQUIPMENT
H.T.PANEL
A-1 Supply, Installation, testing and Commissioning including design, manufacture and testing at
works of 11 KV HT VCB Panel board of 7 panels (2 no. incoming, 4 nos. outgoings & 1 no.
coupler) complete with all interconnections, labels, wiring etc. complete as detailed below
and as per specifications.
322
1 INCOMER - 2 NO.
630 A Vacuum circuit breaker of (350 MVA) 18.4 KA ruputuring capacity at 11 KV rated
totally enclosed, air insulated metal clad housing, floor mounting, vertical isolation, vermin
proof.fully interlocked horizontal drawout type having double isolation features and control
devices as per IS:13118, complete with the following.

.i Manually and motor operated, spring charged (release closing mechanism) trip free type,
pole truck mounted draw out Vacuum circuit breaker , incorporating mechanical as well as
electrical ON/OFF indication. Spring charge/discharge mechanical indication, OFF push
buttons for emergency trip (shrouded) test/ service position limit switches with 6 NO/6NC
breaker aux. contacts in service position.24 V DC shunt trip coil and 230V AC strip heater to
prevent moisture absorption. 630 amp air insulated but encapsulated, PVC insulated copper
bus bars etc as required.

ii CT chamber with double wound, dual ratio C.T's 200/100/5+5A separate core for metering
and separate core for protection.

Page-67 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

a 15 VA burden for protection (class 5P 10)


b 15 VA burden for instrumentation (accuracy class 1.0)
iii Voltage Transformer with 3 numbers 1 phase, 3 limbs connected in star dual class, 11KV/
3/110/ 3with drawable type with automtic shutters 100 VA burden on bus side with primary &
secondary fuses and isolating plugs, (Confirming to relevant IS specification).

iv Protection arrangement for the incoming breaker shall comprise of the following:

a. Numerical relay for over current & Eart fault protection - Areva P- III or equivalant of ABB /
Crompton make.
b. Anti pumping relay (94)
c. Master trip relay (86)
d. U/V relay.
v All wiring necessary for the above including interconnections. The size of the conductor
should not be less than 2.5 sq.mm. Copper wire where required.

vi Test terminal block fuses/2A SPMCB, circuit labels, set of phase, indication lamps etc. as per
standard practise as under :

a Red-Breaker close (ON)


b Green-Breaker open (OFF)
c Amber-auto trip
d Clear - trip circuit health
e White - 3 nos. one per phase
f Blue spring charged.
vii The following meters are to be provided.

a Digital multifuction meter for Montoring Voltage , Current , KWH & Frequency with shrouded
terminal & protection fuses.
b Ammeter range 0-100A-200A with necessary Ammeter selector switch dual graduated scale
shrouded termnal & 144 x 144 mmsq size.

viii 6-window annunciation panel with audio and visual indicator.

a Over current & earth fault 2 windows


b Spare 4 windows.
ix Necessary D.C supply healthy indication lamp and switch.
x control ;- T.N.C (Trip Neutral close) breaker control switch.
xi Cable end terminal boxes with single gland trifurcating cable box suitable for 11KV
aluminium XLPE (E) armoured cable of size 3x300Sq.mm for incoming breaker. Cable entry
shall be from bottom of the panel.

xii HT Danger Plate (as per IS specification)

Page-68 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

xiii 50x6 mm GI earth bus shall be provided for the full length of the panel.(2 Runs).

2 OUTGOING PANELS - 4 Nos.


Each outgoing 11 KV VCB panel for distribution transformer of 2000KVA shall be provided
with following :-
i Item no.I, .i, iv(b), iv(c), v, vi(a to f), ix, x, xii as detailed above for incoming panel shall be
provided for each of the outgoing panel and in addition following items shall be provided.

ii CT chamber with 1set of 2 core CTs with dual ratio 200/100/5+5amps.


15 VA burden for protection (accuracy class 5P10)
15VA burden for metering (accuracy Class 1.0)

iii Following protection shall be provided.


a) Numerical relay for over current & Eart fault protection - Areva P- III or equivalant of ABB /
Crompton make.
b) Auxalliry relay for T/F - for winding temp. , high alarm & tripping.
iv Following meters shall be provided.
a) Digital multifuction meter for Montoring Voltage , Current & Frequency with shrouded
terminal & protection fuses.
v 6-window annunciation panel with audio and visual indication.
a Over current & earth fault- 2 windows (CDG61).

b Oil temperature alarm & trip - 2 windows (OTI).


c Winding temperature alarm & trip - 2 windows (WTI).
vi Cable endTerminal boxes with single gland trifurcating cable box suitable for 11KV aluminium
XLPE (E) armoured cable of size 3x185Sq.mm for outgoing breakers.

3 COUPLER PANEL - 1 NO.


11 KV VCB coupler panel shall be provided with following :-
Item no.I, .i, iv(b), iv(c), v, vi(a to f), ix, x, xii as detailed above for incoming panel shall be
provided for each of the outgoing panel. board 1
323 A-2 2000 KVA TRANSFORMER (CAST RESIN DRY TYPE)

Page-69 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

Supply, installation, testing and commissioning of Cast Resin Dry Type 2000 KVA 11/0.433
KV,3 phase, 50 Hz, Dyn11 vector group, copper wound, class F insulation associated with
winding temperature indicator/controller actuated by means of resistance temperature
detector embedded in LV windings, indoor type Transformer with approximately 5%
impedence, tappings for OLTC, RTCC & AVR Operation on HV side in steps of +5% to
-15%, @ 1.25%, having cable end boxes on HV side suitable for 3x185 Sqmm XLPE cable
of 11KV grade and 2500 Amp. bus trunking arrangement on LV side with neutral brought out
separately including supplying and laying of copper conductor multicore control cable from
transformer to HT breaker for safety tripping, suitably mounted on M.S.channel i/c supplying
and grouting of suitable M.S. Channel with all accessories and confirming to IS 11171:1985 &
complete in all respects as required at site.

each 2
324 A-3 L.T.PANEL
Supply,Installation,Testing and Commissioning of L.T.Panel suitable for 415
Volt,3phase,4wire 50Hz AC supply system fabricated in compartmentlized from CRCA sheet
steel not less than 2mm thick duly treated with 7 tanks process, powder coated with approved
shade and oven dried . The complete panel will have a short circuit with stand capacity of 31
MVA for 1 Second, IP 42 rating. It will have a suitable MS base channel powder coated. The
panel will be fabricated in transportable sections. The panel shall have a common copper
earth bar of size 25mm x 5mm at the rear with 2 Nos. earth studs. The LT panel will have
suitable arrangement for bus-ducting/ cable termination into various incoming/outgoing
switchgear as required. Cable termination will be at suitable terminal block at top/bottom of
the panel and from the terminal block to switch, connection will be made with solid insulated
strip/PVC insulated copper conductor cable of required current rating as required. For other
construction details, refer to section IV of CPWD specifications, part IV- substations.

The panel shall be complete with following switchgear and accessories.

1 INCOMINGS FROM TRANSFORMER (2000KVA)

Page-70 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

2 nos. of 3200 amp rating motor operated spring charging four pole ACB (EDO) for 2000 KVA
transformer incomings , horizontal drawout type suitable for bus duct connection on incoming
side. The ACB shall be electrically interlocked covering 24V DC shunt trip circuit, under
voltage circuit & closing with bus couplers. and DG incomer .The panel shall be suitable for
operation on AMF. The breakers shall be provided with following:-

a Microprocessor release (SR-18G) having variable range of overcurrent, short circuit and
earth fault protection.
b U/V relay.
c TNC breaker control switch.
2 INCOMER FROM DG SET (1500KVA)
2 no. of 2500 amp rating motor operated spring charging TP ACB (EDO) for 1500KVA DG set
incoming , horizontal drawout type.The ACB shall be electrically interlocked covering 24V
DC shunt trip circuit, under voltage circuit & closing with bus couplers. and transformer
incomer. The panel shall be suitable for operation on AMF. The breakers shall be provided
with following:-

a Microprocessor release (SR-18G) having variable range of overcurrent, short circuit and
earth fault protection.
b 315 Amp. TP contactor for neutral.
c TNC breaker control switch.
d Reverse power relay with 5P 10 CT.
e U/V relay.
f Overvoltage relay.
3 Incomer panels from Transformer/ DG sets shall be provided with the following
indications/metering.
The indicating panel of the each Transformer incomer ACB shall be provided with the
following.
a MFM meter with CT`s. for Voltage , Current , KWH & P.F .
b 3 Nos. Phase indicating lamps backed upwith MCB.
c ON/OFF/ Trip indicating lamps
d Separate CT`s shall be provided for protection/metering / APFCR.
g CT for APFCR in T/R incomer panel (Ratio as per requirment of the capacitor panel)

4 Bus Bar
Set of 3600Amps rating TPN Almunium Bus Bars of suitable length shall be provided for
entire length of panel board.
5 Bus Coupler

Page-71 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

1 no. of 3200 amp rating motor operated spring charging four pole ACB (EDO), horizontal
drawout type.The ACB shall be electrically interlocked covering 24V DC shunt trip circuit,
under voltage circuit & closing with Transformer and DG incomers .The panel shall be
suitable for operation on AMF. The breakers shall be provided with following:-

TNC breaker control switch.


6 Outgoing Panels
All outgoing ACB panels shall be provided with DN -1 release and MCCB Panels shall be
provided with thermal / magnetic release and one set of ON/OFF indication lamps with
protection MCB, and Ammeter of suitable range with Ammeter selector switch and CT's as
required.

a Following outgoings shall be on Bus section 1 (transformer no-1)

i 1250A 4P ACB (MDO) ------------------1 No.


ii 800A 4P ACB (MDO) ------------------4 Nos.
iii 630 amp, 50KA TP+NL MCCB ----------------- 2 Nos.
iv 400 amp, 50KA TP+NL MCCB ---------------- 2 Nos.
v 200 amp, 50KA TP+NL MCCB ----------------- 2 Nos.
c Following outgoings shall be on Bus section 2 (transformer no-2)

i 2500A 4P ACB (EDO) ------------------ 1 No.


ii 1250A 4P ACB (MDO) ------------------ 1 No.
iii 630 amp, 50KA TP+NL MCCB ----------------- 2 Nos.
iv 400 amp, 50KA TP+NL MCCB ----------------- 2 Nos.
v 200 amp, 50KA TP+NL MCCB ----------------- 2 Nos. board 1
Supply, Installation, Testing and Commissioning of power back with 220 volt AC input & 24
volt DC continuous output suitable for closing / tripping / indication of 7 nos. HT panel boards
with 2 nos. 12 volt each maintenance free batteries of 100 (suitable) AH each, charging unit,
capacitor bank for emergency delivering for trip system complete with suitable capacity of
Ammeter & Voltmeter i/c connections with 2.5 sq.mm FRLS insulated copper conductor cable
etc. as required.
325 A-4 job 1
A-5 CAPACITOR PANEL

Page-72 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

326 Supply, installation, testing and commissioning including design, manufacture at works of 600
KVAR capacitor bank and panel consisting of suitable capacity bank of capacitor units in tier
formation, housed in an integrated cubicle type, indoor type automatic switching 'ON' and
'OFF' control panel with microprocessor based automatic power factor correction panel of
minimum 12 stages, dust and vermin proof hinged and lockable doors complete with
interconnections, bonding to earth and painting (suitable for 415Volts, 3 phase 50 Hz supply
system). Each capacitor panel shall consists of the following:

1 Incoming
1 No. 1250 amp 4P ACB (MDO) with microprossor based relay for O/L & S/C.

2 Indicating panel
i 0-1200 Amp Ammeter with required CT's & selector switch.
ii Phase indicating lamps
iii Indicating lamp for each capacitor unit to indicate that unit is "ON/OFF".

v APFCR Stepped relay with 12 steps.


3 Outgoings
The capacitor bank shall be compresing of 4X100 KVAR ,3X50KVAR &2X 25 KVAR capacity
capacitor unit .
Each outgoing for capacitor units shall be provided with the following:
a TP MCCB, suitable capacity with thermal / magnetic release and trip setting as required with
heavy duty solid neutral link.
b Capacitor duty contactors of required rating.
c Capacitor units shall be with discharge resistance.
d Push button stations 'RED' and 'GREEN' push buttons for manual operation of capacitors.

e Toggle switches for changing automatic to maual operation of capacitors.

f Terminal blocks for terminating outgoing connections.


g All interconnections from the bus bars to MCCB and MCCB to contactor and contactor to
terminal blocks. panel 2

A-6 BUS DUCT

Page-73 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

327 Supply, installation, testing and commissioning including design, manufacture at works of
sheet steel enclosed sandwitched 3200A, 65KA TPN "AL" bus duct (IP-55) suitable for 415
V, 3 phase 4 wire 50 Hz AC supply system for indoor installation complete with bends ,
expansion joints, fire barriers ,copper flexible end connection at both ends , insulating
materials, all mounting accessories, necessary steel structure support with down rods, dash
fastner etc. complete as required and as per specifications including two runs of copper earth
bus of size 25X5 mm strips etc. as required from transformer to LT panel.

metre 65
328 A-7 Supply, installation, testing and commissioning including design, manufacture at works of
sheet steel enclosed sandwitched 2500A, 50KA TPN "AL" bus duct (IP-55) suitable for 415
V,3 phase 4 wire 50 Hz AC supply system for indoor installation complete with bends ,
expansion joints, fire barriers ,copper flexible end connection at both ends , insulating
materials, all mounting accessories, necessary steel structure support with down rods, dash
fastner etc. complete as required and as per specifications including two runs of copper earth
bus of size 25X5 mm strips etc. as required from LT panel to AC plant and from DG Set to
DG Incommer Panel.

metre 50
A-8 Auxiliary AC supply panel for ESS
329 Supply, installation, testing and commissioning of LT panel boards of 2mm thick sheet steel
cubical design for indoor mounting factory fabricated suitable for operation on 440V 3 phase,
50 Hz, AC supply with MCCBs / MCB and other accessories complete in all respects
including internal wiring, lables, ferrules, cable termination gland plates, earth terminals,
painting etc. conforming to specification. All MCCB shall be with rotary handle.

INCOMING:-
One No. 200A. TPN MCCB 35KA
BUS BAR:-
one set of 250Amps. TPN busbars of aluminium alloy with coded heat PVC shrinkable
sleeves.
OUTGOING:-
3 Nos. 63Amps. TPN MCCB
3 Nos. 40 Amps. TPN MCB
INDICATION:-
3 Nos. LED type phase indicating lamps with protection 2A SP MCBs

Auxiliary panel complete as required with details described as above and as per
specifications. panel 1

Page-74 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

SUBHEAD -B HT/LT CABLE, CABLE TERMINATION & CABLE TRAY


B-1 H.T. CABLE
330 Supply and laying / fixing of followig size of 11 KV XLPE insulated aluminium conductor
earthed and armoured cable conforming to IS 7098 (Part -II) complete as required in ground,
including excavation ,sand cushioning & brick cover or on surface or on cable tray.

a 3 Core, 300 sq.mm metre 350


b 3 Core, 185 sq.mm metre 50
B-2 H.T. CABLE TERMINATION

331 Supply & making Indoor cable end termination with heat shrinkable cable termination kit with
all accessories including crimped cable lugs suitable for the following sizes of three core
XLPE aluminium conductor cable of 11KV grade as required.

a 3 Core 300 sq.mm each 4


b 3 Core 185 sq.mm each 4
B-3 LT CABLES

332 Supply of following sizes of 1.1 KV grade multicore aluminium conductor XLPE insulated and
PVC sheathed armoured cable conforming to IS 1554 (Part-I) 1988.

a 3.5 Core, 400 sq.mm. XLPE AluminiumCable metre 120


b 3.5 Core, 300 sq.mm. XLPE AluminiumCable metre 900
c 3.5 Core, 240 sq.mm. XLPE AluminiumCable metre 450
d 3.5 Core, 185 sq.mm. XLPE Aluminium. Cable metre 1700
d 3.5 Core, 120 sq.mm. XLPE Aluminium. Cable metre 250
e 3.5 Core, 95 sq.mm.XLPE Aluminium Cable metre 30
B-4 LAYING/FIXING OF 1.1KV GRADE CABLES
333 Laying and fixing of one number XLPE insulated and PVC sheathed armoured power cable
of following size of 1.1 KV grade on surface or cable tray etc as required.

Size 3.5 C, 120 sq.mm. to3.5C 400 sq. mm XLPE AluminiumCable metre 50

334 B-5 Laying and fixing of following sizes of one number XLPE insulated and PVC sheathed
armoured power cable of following size of 1.1 KV grade directly in ground including
excavation, sand cushioning, protective covering & refilling the trench etc. as required.

Size 3.5 C, 120 sq.mm. to3.5C 400 sq. mm XLPE AluminiumCable metre 2000
335 B-6 Laying and fixing of one number additional XLPE insulated and PVC sheathed armoured
power cable of following size of 1.1 KV grade directly in ground including excavation, sand
cushioning, protective covering & refilling the trench etc. as required.

Page-75 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

Size 3.5 C, 120 sq.mm. to3.5C 400 sq. mm XLPE AluminiumCable metre 1200
336 B-7 Laying of one number XLPE insulated and PVC sheathed armoured power cable of following
size 1.1 KV grade in existing masonary open duct / pipe etc. as required.

Size 3.5 C, 95 sq.mm. to3.5C 400 sq. mm XLPE AluminiumCable metre 200

B-8 END TERMINATIONS OF 1.1KV CABLES


337 Supply and making cable end termination with brass compression glands and crimped
aluminium lugs following sizes of PVC sheathed / XLPE aluminium conductor cable of 1.1 KV
grade of the following sizes as required.

a 3.5 Core, 400 sq.mm. XLPE AluminiumCable each 4


b 3.5 Core, 300 sq.mm. XLPE AluminiumCable each 8
c 3.5 Core, 240 sq.mm. XLPE AluminiumCable each 4
d 3.5 Core, 185 sq.mm. XLPE Aluminium. Cable each 14
d 3.5 Core, 120 sq.mm. XLPE Aluminium. Cable each 4
e 3.5 Core, 95 sq.mm.XLPE Aluminium Cable each 2
B-9 CABLE TRAY / RCC PIPE
338 Perforated type Cable Tray
Fabricating and installing fllowing size of perforated MS cable trays including horizontal and
vertical bends, reducers, tees, cross members and other accessories as required and duly
suspended from the ceiling with MS suspenders and including painting etc. as required

a 600 mm width x 50 mm depth x 2.0 mm thickness metre 30


b 450 mm width x 50 mm depth x 2.0 mm thickness metre 40
c 300 mm width x 50 mm depth x 1.6 mm thickness metre 20
339 B-10 Providing and laying non-pressure NP2 class (light duty) RCC. Pipes with collars jointed with
stiff mixture of cement mortar in the proportion of 1:2 (1 cement:2 fine sand) including
excavation ,laying testing of joints & back filling etc. complete.

a 250mm dia . RCC pipe metre 50


b 300mm dia. RCC pipe metre 80

B-11 CONTROL CABLE


340 Supply and laying / fixing of followig size of 1.1 KV PVC insulated Copper conductor
armoured cable conforming to IS 1554 (Part -I) complete as required in ground, on surface or
on cable tray.
a 2X1.5 sq.mm metre 100
b 4X 1.5 sq.mm metre 150
c 8X 1.5 sq.mm metre 80

Page-76 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

SUBHEAD -C SAFETY EQUIPMENT


341 C-1 Supply & erecting/fixing of the following items in the substation.
a Rubber hand gloves suitable for 11 KV. pair 2
b Shock treatment chart both in Hindi & English for treating person suffering due to electric
shock duly framed with 5 mm thick glass and mounted on wall .
each 4
c Safety Instruction chart both in Hindi & English duly framed with 5 mm thick glass and
mounted on wall as required. each 4
d Providing & Fixing HT danger notice plate of 250 mm x 200mm, made of mild steel, at least
2mm thick & vitreous enamelled white on both sides and with inscription in signal red colour
on front side as required.
each 5
e Providing & Fixing MV danger notice plate of 200 mm x 150 mm, made of mild steel, at least
2mm thick & vitreous enamelled white on both sides and with inscription in signal red colour
on front side as required.
each 5
f Carbon dioxide fire extinguishers of 4.5 kg each mounted on wall hooks as per IS : 2878-
1976 complete with all accessories. each 15
g Chamical foam type fire extinguishers of capacity 24 liters trolly mounted as required.
each 4
h G.I. Fire buckets 13 litre capacity filled with dry sand and fixed on wall on hook made out of
13mm dia MS rod & conforming IS 2546 - 1974. each 4
i First aid box containing material as prescribed by St. John Ambulance brigade OR Indian
Red Cross complete as required. each 1
j Rubber mat 1000 mm wide and 12 mm thick to withstand 15 KV dielectric strength as per IS
5424- 1969. each 10
k Rubber mat 1000 mm wide and 6 mm thick to withstand 3.3 KV dielectric strength.
each 25

SUBHEAD -D EARTHING
342 D-1 Earthing with copper earth plate 600mm x 600mm x 3 mm thick including accessories and
providing masonary enclosure with cover plate having locking arrangement and watering pipe
etc. (but without charcoal and salt) complete as required and as per IS-3043 .
set 8
343 D-2 Extra for charcoal and salt for GI plate or copper plate earth electrode as required.
set 8
344 D-3 Providing & fixing of 50mm x 5 mm copper strip on surface for earth connection as required.
metre 5
345 D-4 Providing & fixing of 25 mm x 5 mm copper strip in 40mm dia GI pipe from earth electrode as
required. metre 80
346 D-5 Providing & fixing of 25mm x 5mm Copper Strip on surface or recess for earth connection as
required. metre 100

Page-77 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

347 D-6 Supply and laying of 6 mm dia. G.I. Wire with LT cables for earth connection as required.
set 6700

PART - II (EXTERNAL LIGHTING)


SUBHEAD -A HIGH MAST, POLES & FITTINGS
348 A-1 Supply of Raising & Lowering type 16M high mast system with following: (Bajaj / Philips /
Crompton Make).
a Mast shaft shall be in two sections, hot dip galvanised, inside and outside in singledip,
suitable for wind velocity as per IS 875 part 3. There shall be only one longitudinal seam weld
per section and no circumferential weld. It shall also include accessories for high mast
including head frame, 2-point suspension system with steel wire rope 6mm dia (7/19
construction) double drum winch, Galvanished Lantern carriage arrangement suitable for up
to 12 luminaires symmetrically, lightning finial and integral power tool for raising and lowering
operation of the High Mast.

b Supply of foundation bolts manufactured from special steel along with nuts, washers, anchor
plates and templates.
c Suppy of Non-integral flood light luminaire IP-65 with 2x 400W SON Lamps and its control
gear boxes - 6 Nos.
d 400W Helogen light fitting - 2 Nos.
e Supply of twin dome aviation obstruction lights LED Type - 1 No.
f Supply of control panel housing suitable control circuit for switching ON and OFF of the mast.
It shall also have suitable controls for operation of Power Tool.

g Construction of suitable shallow foundation with 'M20' grade concrete for the high mast
considering the safe soil bearing capacity at site as 10 T/sqmtr at 2mt depth, suitable DWC /
PVC pipe laid within the foundation for incomming and outgoing cables with all materials and
labour.

h Erection of High Mast with help of suitable equipments and wiring of luminaires with all wiring
material and labour.
i Provision of GI pipe earthing for High Mast with 4.5M long 40mm dia GI pipe including
connection of High Mast earth terminal with 25 x 3mm GI flats with all materials and labour.

j Installation of control panel on suitable foundation including all materials and labour.

h Testing and Commissioning of above High Mast system. each 3

Page-78 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

349 A-2 Supplying, Installation, Testing and commissiong of 7.5mtr high MS decorative type steel
tubular pole with single bracket 500mm, duly primed and painted. The pole shal be painted
with MRF polyurethane paint of approved colour. The bottom and middle embellishments are
cast in iron and fixed to the column by grub screw. The column shall be provided with inbuilt
loop box with 4 way 32Amp Heavy duty connector, 2 Nos SPMCB's with wiring from MCB to
fitting with 3x2.5 sq.mm PVC insulated sigle core wires and shall have matching flush
door,fabricated painted complete with RCC foundation including 4x16mm dia foundation bolts
of 300mm length suitable DWC / PVC pipe laid within the foundation for incomming and
outgoing cables as per the Department's requirement. (Keslec / Twinkle / Bajaj / Hilite Make).

a Top dia - 76mm. Length 6000mm


b Bottom dia - 139mm. Length 1500mm
c Base plate - 300 x 300 x20mm thick duly welded in column.
d RCC foundation 600 x 600 x 1200mm each 43
350 A-3 Supplying, Installation, Testing and commissiong of decorative 3.5 long MS tubular pole light
pole standard pole fabricated out of 70 mm dia. pipe 2.0 metre long and bottom dia of 140
mm 1.5 meter long complete with 300 mm x 300 mm x 6 mm thick MS plate welded at bottom
including wiring with 3x2.5sqmm copper wire from JB to light fitting, connections etc. as
required. Welding of 1 no. earth stud and drilling holes for drawing the wire etc. complete as
required including cement concrete foundation, wiring and connections . A looping/ junction
box shall be inbuilt into the pole.

each 39

351 Supplying, Installation, Testing and commissiong of 70 watt MH Post Top lanteran fitting with
70 watt MH lamp, heavy duty copper wound ballst and accessories.
Philips Post Top decorative liminaire HPS360 1x MHN TD 70 W or simillar equivalent make
as approved.
A-4 a each 39
Supplying, Installation, Testing and commissiong of Post top lantern fixture with 70W SON
LAMP, integral control gear, Philips HPS 360 1x SON 70 or other equivalent make as
approved external light fixtures on gate complete as required with GI pipe support / bracket &
all accessories including control gear, lamps, ballast as required.
b each 5

Page-79 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

Supply,Installation,Testing and Commissioning of IP:66 street light luminaries made out of


die cast Aluminium housing and head frame, powder caated in approved color, high purity
Aluminium pot reflector electrochemically brightened and anodized, heat resistant and
toughened glass cover, gasket including accessories like copper ballast, electronic igniter, PF
improvement Capacitor, duly wired as required (Similar to SGP 398 of Philips).

352 A-5
With CDMT 150W lamp. each 43

SUBHEAD -B CABLES
Supply of following sizes of 1.1 KV grade multicore aluminium conductor XLPE insulated and
PVC sheathed armoured cable confirming to IS 1554 (Part-I) 1988.
353 B-1
a 3.5x95 sqmm XLPE Aluminium Cable metre 450
b 4x16 sqmm XLPE Aluminium Cable metre 1150
b 4x10 sqmm XLPE Aluminium Cable metre 600
b 4x6 sqmm XLPE Aluminium Cable metre 550
Laying of one number PVC insulated and PVC sheathed XLPE power cable of 1.1 KV grade
of size upto 120 sq.mm direct in ground including excavation, sanc cushioning, protective
covering and refilling the trench etc. as required.
354 B-2 metre 2700
Supplying and making end termination with brass compression gland and aluminium lugs for
following sizes of aluminium conductor cable of 1.1KV grade as required:
355 B-3
a 4 x 16 Sqmm each 92
b 3.5 x 95 Sqmm each 4
b 4x10 sqmm XLPE Aluminium Cable each 48
b 4x6 sqmm XLPE Aluminium Cable each 44

SUBHEAD -C FEEDER PILLARS & EARTHING


Supplying, Installation, Testing and commissiong of floor mounting, totally enclosed,
compartmentalized, cubical, dust, vermin proof and outdoor type ROAD LIGHTING PILLAR
fabricated out of 2mm thick cold rolled carbon anealed, sheet steel, intermnally strengthened
with angle iron frame work with following incoming and outgoing feeders (fabricatedout of
2mm CRCA sheet steel) including supplying and mounting and making connectins /
interconnections with lugs / glands crimping tools, testing and commissioning of following
items inside the panel:-

356 C-1
Incoming
100A TPN MCCB(25KA) 1 No.

Page-80 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

63A, 4P Contactor 1 No.


Time Switch with daily dial suitable for operation on 230V single phase 50Hz AC supply
1No.
Auto Manual Selector Switch 1 No.
Bus Bars
TPN bus bar of 100A rating
Outgoings
20A TP MCB 9 Nos.
Indication lamps (LED Type) 3 Nos. each 2
Earthing with G.I. Earth pipe 4.5m long 40mm dia including accessories and providing
masonary enclosure with cover plate having locking arrangement and watering pipe etc
(but without charcoal or coke and salt) complete as required.
357 C-2 set 20
358 C-3 Extra for using salt and charcoal for pipe earth electrode as required. set 20
359 C-4 P/F 25 x 6mm GI earth strip in ground :
Supplying and laying 25mm x 6mm G.I. strip at 0.5 m below ground level as strip earth
electrode including soldering etc. as required. metre 80
Providing and fixing GI earth strip 25x 5mm in 40mm dia G.I. Pipes in ground 500mm deep
360 C-5 as required. metre 60
Providing and fixing 6 SWG dia G.I wire on surface or in recess for loop earthing along with
361 C-6 existing cable as required. metre 4500

362 C-4 P/F 25 x 6mm GI earth strip in ground :


Supplying and laying 25mm x 6mm G.I. strip at 0.5 m below ground level as strip earth
electrode including soldering etc. as required. metre 80

Providing and fixing GI earth strip 25x 5mm in 40mm dia G.I. Pipes in ground 500mm deep
363 C-5 as required. metre 60

Providing and fixing 6 SWG dia G.I wire on surface or in recess for loop earthing along with
364 C-6 existing cable as required. metre 4500

PART - III (DIESEL GENERATING SETS)


SUBHEAD - A DIESEL GEN. SETS

Providing installing / testing and commissioning of Diesel Generating Set having prime
power rating of 1500 KVA at 1500 RPM, 0.8 lagging power factor at 415 volts suitable for 50
365 A-1 Hz, 3 phase system and for 0.85 load factor, consisting of the following.

Page-81 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

Diesel Engine : Radiator cooled electric start Diesel Engine four stroke of suitable B.H.P at 1500
RPM for above out put of alternator at 40 Degree Celiues, 50% RH & at 1000 mtr above MSL &
conforming to BS:5514, BS:649/IS:10000, capable of taking 10% overloading for one hour after 12
a hour of continous operation. The engine will be fitted with all the required accessories.

b Engine Instrument Panel fitted with and having Digital display for the following.
i Start-Stop switch
ii Lubrication oil pressure indication.
iii Lubrication oil temperature indication.
iv Battery charging indication.
v RPM indication.
vi Over speed indication.
vii Low Lube Oil trip indication.
viii Engine Hours indication.
ix Speed Governor
x Heavy duty air cleaner

Alternator : Synchronous alternator rated at 1500 KVA at 1500 RPM, 0.8 lagging P.F. at 415 volts
suitable for 50 Hz, 3 phase system at 40 Degree Celsius, 50% RH and at 1000 mtr. Above MSL. The
alternator shall be having SPDP enclosure, brushless, continuous duty type, self excited / PMG, self
regulated through AVR. The alternator shall conform to IS:4722 / BS:2613 and will be suitable for
tropical conditions. Class of insulation will be H type. (Space heaters, RTD & BTD alongwith cables
c are covered in this item).

Base Frame & Foundation : Both the Engine & Alternator shall be mounted on suitable base frame
made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete
d foundation and vibration isolation arrangement as per recommendation of manufacturer.

Fuel Tank : Daily service fuel tank suitable for 990 Ltrs capacity, fabricated out of 3mm thick MS
sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with
MS class 'C' pipes of suitable dia. Complete with valves, level indications and accessories as required
e as per specification.
Exhaust System : Dry exhaust manifold with residential grade silencer & catalytic converter,
f stainless steel bellows.
Starting System : DC starting system comprising of starter motors, voltage regulator and arrangement
for initial excitation complete with suitable 2 No. 12 V, 180 AH or more capacity, dry type,
g maintenance free VRLA batteries.

Page-82 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

Accoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the
engine and alternator, extraction, discharging hot air into the atmosphere as per
h specifications. set 2

Providing, laying, testing and commissioning of welded black M.S.Exhaust pipe of following
sizes conforming to IS:3589, cut to required lengths and installed with all joints, providing and
fixing in position necessary fittings like bends, reducers, tees, couplers, necessary supports &
clamps, flexible connections, antivibration mountings, hangers, including insulation, with 50
mm thick mineral wool/rock wool of density not less than 46 kg /cubic meter , wire mesh
366 A-2 and 24 SWG Aluminium Cladding etc. as required as per specifications .
a 350mm dia. 5.2mm thick metre 75
b 250mm dia. 5.2mm thick metre 40

PCCM based DG Auto synchronization, Auto Load Management, Auto load sharing control
367 A-3 logic panel. (Micrologix, PLC Based) comprising of the following:
Engery analyzer with RS 485 port
Battery charges (with trickle and boost charging)
DC Voltmeter and Ammeter
Engines Cranking Relay
Main Supply Voltage Monitor
Auxiliary Relays, Timer, Push Button and Control MCCB's
Trip Circuit Supervision Relay
Master Lock Out Relay

12 Windows Alarm Annunciator with Separate Hooter, Accept Rest and Rest Push Button
Set Running Indicating Lights : 230 volt
DG Start Stop Push Button
Time Totalizer
Voltage Monitor for DG Supply
Voltage Monitors for Main Supply
Selector Switch Auto / Manual
Selector Switch DG Selection
8 Channel Scanner
Windows based Operator Interface Grafix Software for Monitoring
CPU (Allen Bradley / Siemens / ABB / Schneider) with desk.
Power Supply Module

2 KVA, single phase input and single phase output, 240 volts, 50 Hz, AC, online UPS with
inbuilt 30 minutes battery backup in form of sealed maintenance free batteries with power
wiring to the control bus for power supply to relays. (To be installed inside the panel).

Page-83 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

Auxiliary relays for Output Command


PC with P-IV Intel Processor, 80 GB Hard, 1 GB RAM, 15" TFT Colour Monitor PCI-VGA card
2 MB, DVD Driver (reader and writer)
Priming Pump Starter with priming timer of PIC make (DOL-2HP)
Micrologix - 1500 (PLC)
KW Transducer
Earth Fault Relay

The Synchronizing System shall be provided with following feature and audible alarm:
Engine Starter Control
Speed Monitoring
Over Speed Protection
Oil Pressure Monitoring, Alarm and Shutdown of the Engine
Water Temperature Monitoring, Alarm and Shutdown of the Engine.
Battery Voltage Monitoring
3 attempt start failure alarm
Under / Over Frequency
Reserve Power (inverse time delay)
Over Current (inverse time delay)
Loss of Utility Power Detection
Load Surge
Current Unbalance
Voltage Unbalance
Configurable Loading / Unloading Ramp Rates
Base Load Control for Optimum Fuel Efficiency Set 1
A-4 Exhaust System

Page-84 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

Supplying the necessary materials and making support tower for Exhaust chimney for D.G
Sets including Design and preperation of the drawings for exhaust chimney with provision of
sampling ports for all types of stacks, submission and obtainign approval and necessary
certificate from pollution control board and other statutory authorities.
Exhaust chimney shall be taken upto height of min. 30mtrs above ground level and shall
conformed to the statutory regulatins by Environment authorities and shall be as per
specificatgions. Structural design of support structure shall also be in the scope of contractor
that will include all concrete foundation including excavatin and disposal of surplus earth,
steel reinforcement, ladder for all connected works including lightening arrester, earthing and
2 Nos. aviation obstruction lights.
The chimney shall be self supporting type and shall include and support necessary holding
down bolt arrangements. The civil and steel structural works required for the chimney is also
included in the scope. The sports structure and chimney shall follow specifications in the
368 attached Annexure.
a Steel Fabrication (Welded M.S) Kg 12 000
b RCC Foundation Cum 100
A-5 M.S Tank (Bulk Storage)

Supplying, installation, testing and commissioning of M.S Tank 20KL capacity fabricated out
of 6mm thick M.S Plate with bracing's inside for providing strength to sheet metal work,
complete with all standard apparatus / mountings like manhole of 600mm dia and cover duly
hinged, access ladders, lifting lugs, earthing bolts etc. Dish ends of 8mm thick M.S sheet, fuel
fill pipe 80mm dia with locking arrangement, vent pipe, outlet pipe Brass dip stick, with
calibrater chart (As per IS Code 10987 - 1992 Tank fabricated from MS sheet of 6mm
thickness and two level indicators. The tank shall be duly painted with two coats of tank
mastic and two coats of Tar Plastic paints outisde of tank and any other treatment required
for corrosioin resistance as per standar practice and requirement. Tank shall be provided with
level switches High / Low.

369

Page-85 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

The rates quoted shall be complete with connected civil work including excavation, half round
RCC foundation as required, completes with foundation bolts and strapings duly anchored to
foundations, sand fill, disposal of surplus earth, debris as required for installation of tank
including fire fighting system, security fencing, etc as required liassioning with corcerned
Govt. Authorities and NOC from D.M (DC) and local Authorities getting permission shall be
contractors responsibility. Tank to be hydrallicaly tested to meet requisite standard / 3m water
columns head whichever is higher. Certificate to the above affect is required . Any other
functinal requirement as per site condition shall also deem to have been included in the
scope fo this item. set 1
A-6 Buffer Tank & Overflow Tank

Supplying, installation, laying, testing and commissioning of Buffer Tank of 990 Ltr. Capacity,
over flow tank of 990 ltr capacity, fuel transfer pumps, strainers, valves, pipes, bends,
supports, clamps complete as shown in the Line Diagram including cost of hydraulic testing
370 with valves, strainers and adopter complete as required.
i 990 Ltr capacity tank fabricated out of 3mm, thick MS Sheet - 2 Nos.
Fuel transfer gear type pump set coupled with single phase flame proof motor capable of
ii delivering.
a). 50 LPM (from U/G tank to day oil tank) - 2 Set
b). 35 LPM (from overflow tank to U/G tank) - 2 Set
iii Push Button Station for fuel transfer pump sets - 4 Set
iv M.S Pipe (C-Class) quantities shall be as per site requirements.
a 80mm dia
b 50mm dia
c 40mm dia
d 25mm dia
v Pipe Accessories
a 80mm adopter suitable for oil company delivery hose - 1 No.
b 80mm brass ball valves - 5 Nos.
c 80mm strainer with SS Screen 80/100 mesh - 1 No.
d Oil recording thermometer (mechanical type) - 1 No.
e Pressure guage with siphon and guage cock - 1 No.
vi Ball - Valves
a 50mm dia - 8 Nos.
b 25mm dia - 7 Nos.
vii Foot Valve
a 50mm dia - 2 Nos.
b 25mm dia - 1 No.
viii Non Return Valve

Page-86 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

a 50mm dia - 2 Nos.


b 25mm dia - 2 Nos.
ix Y-Strainer
a 100mm dia - 1 No.
b 50mm dia - 2 Nos.
c 25mm dia - 2 Nos.
x Cables (quantity shall be as per site requirement)
a 3C x 4 sqmm Cu conductor
b 3C x 2.5 sqmm Cu conductor
c 12C x 2.5 sqmm Cu conductor
d 3C x 1.5 sqmm Cu conductor set 1

Note: - The schematic drawing showing bulk storage tank, buffer tank, overflow tank, pipes, valves
ect. In addition to BOQ, if there is any functional rquirement / alteration as per the requirement at site,
the same shall to be executed without any cost implication. Location of buffer tank and over flow tank
shall be in DG Room / Sub-Station Room and loation of bulk storge tank shall be at a distance of 15m
(approx.) from DG Sets.

Fabricating and installing following sizes of perforated M.S. cable tray including horizontal &
vertical bends, reducers, tees, cross members and other accessories as required duly
371 B-1 suspended from ceiling with M.S. Suspenders, including painting etc. as required.
a 300mm width x 50mm depth x 2mm thick metre 30
b 150mm width x 50mm depth x 1.6mm thick metre 30
Total Subhead B

Earthing with copper Earth Plate 600mm x 600mm x 3mm thick I/c accessories and providing
masonary enclosure with cover plate having locking arrangement and watering pipe etc. (but
372 C-1 without charcoal or coke and salt) complete as required. set 4

373 C-2 Extra for using charcoal / coke and salt for GI or copper plate earthing electrode as required. set 4
Providing and fixing 25mm x 5mm copper strip in 40mm dia GI pipe from earth electrode as
374 C-3 required. metre 20
Providing and fixing 25mm x 5mm copper strip on surface or in recess for connection etc. as
375 C-4 required. metre 30

3 FIRE PUMPS, VALVES & ACCESSORIES


Supply, Testing, Installation, Testing & Commitioning of Electrical Motor Driven Fire
Pumping set suitable for automatic operation consisting of the following as per the
376 3.1 specifications.

Page-87 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

Providing and fixing horizontal split casing single/multi stage, single pumping set with bronze
impeller with gland capable of delivering 2850 LPM against a total head of 75 M with C.I.
body and connected by a flexible coupling to a totally enclosed fan cooled induction motor
mounted on a common structural baseplates with all pump accessories complete as per
specifications including pressure gauge with gunmetal isolation valves and anti vibration
pump, motor to be suitable for 415 volts, 3 phase, 50cycles A.C. supply( specification as per
fire fighting requirements and on the pattern of TAC OR LOCAL AUTHORITY APPROVAL)
as per instruction of following specifications:

b) Squirrel cage induction motor totally enclosed fan cooled type suitable for 415 volts ±15%,
3 phase, 50 Hz AC supply of suitable capacity (approximate 60 KW) for the above pump
coupled with flexible coupling including earthing as per relevant Indian standard &
specifications.
c) Common bed plate for mounting pump and motor fabricated from suitable MS Channel as
per manufacturer's recommendations.
d) Suitable RCC pump-foundations as per manufacturer's design and 4 nos. dunlop (cushy
foot) heavy duty antivibration mounting pads. Set 2

Supply, Testing, Installation, Testing & Commitioning. Of Diesel Engine Driven Fire
Pumping set suitable for automatic operation consisting of the following as per
377 3.2 specifications:
Providing and fixing horizontal split casing single multi stage, single pumping set with CI body
and bronze impeller & with gland capable of delivering 2850 lpm against a total head of
75m connected by means of a flexible coupling to a water cooled diesel engine mounted on
a common structural base plate with antivibration pads and and foundation complete with
electric panel, battery (including one spare battery), utomatic starting arrangement exhaust
pipe of required length to discharge outside building with muffer, day oil tank mounted on
suitaible structural supports complete in all respects as per specifications ready for use and
as per latest requirement of fire autority regularities.

b) Water cooled TAC approved Diesel Engine suitable for developing at least 60 BHP at 1800
RPM) compatible for above pump complete with automatic starting mechanism, batteries,
automatic battery charger unit, flexible coupling with the pump, fuel tank, silencer, exhaust
pipe with insulation approx. 25m length & all standard accessories as required as per TAC
rules including earthing, mandatory spares and tool kit.

Page-88 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

c) Common bed plate for mounting pump and engine fabricated from suitable MS Channel as
per manufacturer's recommendations.
d) Suitable RCC pump foundations as per manufacturer's design 8 Nos Dunlop Anti-vibration
(cushy foot) heavy duty mounting pads. Set 1

Supply, Testing, Installation, Testing & Commitioning. of Electrical Motor Driven


Automatic pressurisation (Jockey) pumping set consisting of the following as per
378 3.3 specifications.

Providing and fixing horizontal split casing single/multi stage, single/multi outlet pumping set
with bronze impeller & with gland capable of delivering 180 LPM against a total head of 75
M with C.I. body and connected by a flexible coupling to a totally enclosed fan cooled
induction motor mounted on a common structural baseplates with all pump accessories
complete as per specifications including pressure gauge with gunmetal isolation valves and
anti vibration pump, motor to be suitable for 415 volts, 3 phase, 50cycles AC supply
(specification as per fire fighting requirements and on the pattern of TAC OR LOCAL
AUTHORITY APPROVAL) as per instruction of following specifications:

b) Squirrel cage induction motor totally enclosed fan cooled type suitable for 415 volts ±15%
3 phase 50 Hz AC supply of suitable capacity (approx. 15 KW) for the above pump with
synchronous speed of 1500/3000 RPM confirming to IS:325 & duly coupled with above pump
coupled with flexible coupling including earthling as per relevant Indian Standard and
specifications.
c) Common bed plate for mounting Pump and Motor fabricated of suitable M.S.Channel
as per manufacturer's recommendations.
d) Suitable RCC Pump foundations as per manufacturer's design 4 Nos Dunlop Anti-vibration
(cushy foot) heavy duty mounting pads. Set 2

Providing, fixing, testing and commissiong of double flanged vertical air vessel fabricated
from 10mm MS plate with dished ends from 10mm MS plate, outside with one coat of primer
and two coats of synthetic enamel paint of approved shade, complete with approved quality
of pressure switches, pressure gauge and all other required accessories to operate
commonly main fire pump, sprinkler pump and Jockey pump at drop of pressure,
379 3.4 automatically at required pressure setting;
Recommended dia. : 450mm
Height of shell : 2000mm
Working pressure : 7 kg/cm2
Test Pressure : 10 kg/cm2 Each 2

Page-89 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

380 3.5
Providing, fixing, testing and commissiong of motor control centres fabricated from 16 gauges
MS sheet with powder coated finish. The control panels should be comparable with H.P. of
the motor as specified.

Panel for fire pumps

Providing and fixing motor control centres fabricated from 16 gauge M.S. sheet with Powder
Coated finish. The control panels should be compatible with H.P. of the motor as under and
as per spcifications with automatic star delta starters. (One separate panel to be located in
the plant room).

a) One incoming main isolation MCCB TP of Min. 250 Amps. rating.

b)
Fully taped aluminium bus bar of required capacity in a separate bus bar chamber.

c) Isolation MCCB for each unit of required rating and with fully automatic starter as per
requirement with push button and ON/OFF indicating lights for each unit, for following
requirements:
i) One main fire pump of 85 HP.
ii) One main Sprinkler pump of 85 HP.
iii) Two jockey pump of 20 HP (Each).
iv) One Diesel Pump Controlling System

d) Single phasing preventors of suitable rating one for each motor.

e) Rotary type Auto/Manual/ ON/OFF selection switches.

f) One 96 mm square panel type voltmeter reading 0-500 V with rotary selector switch for
reading voltage between phases.

g) One 96mm square panel type Amp. meter reading 0-500 Amp. for main fire pump and
sprinkler pump.

h)
One 96mm square panel type Amp. meter reading 0-500 Amp. for each Jockey pumps.

i) Appropriate etched plastic plate for each starter/switch.

Page-90 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

j) Colour coded internal wiring from incoming main to bus bar, switch gear, starters, meters
indicating lamp etc., complete in all respects. set 1
(Complete set included item (a) to (j).

381 3.7
Providing and fixing resilient rubber neoprene lined single arch vibration eliminators suitable
for raw water upto 450C temperature working pressure 7 kg/cm2 and test pressure 14 kg/cm2
with unit control.
3.7.1 50 mm dia Each 2
3.7.2 65 mm dia Each 4
3.7.3 80mm dia Each 6
3.7.4 100mm dia Each 4
3.7.5 150 mm dia Each 4

382 3.8 Providing and fixing CI double flanges suction strainer (PN 2.0) “Y” type including, nuts, bolts
and 3mm thick rubber insertion complete.
3.8.1 80mm dia Each 1
3.8.2 100mm dia Each 1
3.8.3 150mm dia Each 3
3.8.4 200mm dia Each 2

383 3.9
Providing and fixing brass/bronze lever operated ball valve of full flow with stainless steel ball
(AISI 304 and spindle AISI 410) with setting and gland of superior quality having minimum
working pressure of 20 kg/cm2.
3.9.1 15mm dia Each 1
3.9.2 20mm dia Each 1
3.9.3 25mm dia Each 4
3.9.4 32mm dia Each 1
3.9.5 40mm dia Each 2
3.9.6 50mm dia Each 3
3.9.7 65mm dia Each 4

384 3.10
Providing and fixing butterfly valves, wafer end type class PN 1.6 as per IS: 13095-1991 or
BS: 5155, including necessary nuts, bolts, gaskets etc. complete (without gear box)
3.10.1 80mm dia nominal bore. Each 2
3.10.2 100mm dia nominal bore. Each 4
3.10.3 150mm dia nominal bore. Each 6
3.10.4 200mm dia nominal bore. Each 2

Page-91 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

385 3.11
Providing and fixing CI double flanged horizontal/ vertical type non-return valve including
nuts, bolts, 3mm thick rubber insertions complete to IS:5312, part-I, swing type, class PN 1.6.
3.11.1 65mm nominal bore Each 2
3.11.2 80mm nominal bore Each 2
3.11.3 100mm nominal bore Each 4
3.11.4 200mm nominal bore Each 2

386 4
Providing, fixing,testing and commissiong of standard mild steel flanges, (only in valves,
strainers, expansion joint and pumps matching flanges) screwed or welded complete with
1.5mm thick compressed asbestos gasket, nuts, bolts and washers etc., complete including
testing of joints. The flanges shall be as per IS 6392 table E.

a) 200mm dia Each 10

b) 150mm dia Each 12

c) 100mm dia Each 10

d) 80mm dia Each 30

e) 65mm dia Each 27

f) 50mm dia Each 20

387 5
Providing, fixing of G.I. earthing wire 8 SWG from all motor and MCC panels to be connected
in a approved manner to the general earthing system complete. Metre 175

Providing and fixing G.I. Earthing strip of Size 25 x 3mm for higher size motors and MCC
388 6 panels to be connected in as approved manner to the general earthing system complete. Metre 200

Providing earthing station with GI Earthing Plate for pumps and MCC panels including
389 7 excavation, CI manhole cover and frame complete as per specifications and IE rules. Each 8

Providing and fixing pressure switch (for operation at 0-15 kg/cm2) with required fittings and
390 8 accessories complete. Each 5
Total Price of Section C

Page-92 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

SECTION- D- Pumps, Water Treatment & Allied Equipment


Raw Water Pump (P-1)

Providing, fixing, testing & commissioning of horizontal split casing multistage centrifugal
pumping set with stainless steel SS-304 stage casing and SS304 impellers with stainless
steel SS304 shaft as per IEC standards and GJL250 cast iron suction & discharge casing,
connected to TEFC ventilated induction motor of 2 pole, 2900 RPM, suitable for 400/440
volts, 3 phase, 50 Hz AC supply with pressure gauge and with gunmetal isolation cocks,
vibration elimination pads etc. complete with base and frame, nuts and bolts and necessary
391 1 RCC foundations as per requirement as per instructions and pump shall have following duty.
No. of Pumps : 3 (2 working + 1 stand by )
Capacity : appox. 760 LPM
Head : 30m
Model :- DPVF 45-20 , 7.5 Kw Each 2

a) (For Domestic Water Supply)


Pump No. P - 2
No. of Pumps : 2 (1 Working + 1 Stand by)
Capacity : app. 300 LPM
Head : app. 64 M
No. and capacity of Pressure Vessel – 2 Nos. x 450 Ltrs Set 1
Model :- DPVF 18-60 , 5.5 Kw

b) (For Flushing Water Supply)


Pump No. P - 4
No. of Pumps: 2 (1 Working + 1 Stand by)
Capacity : app. 130 LPM
Head : app. 64 M
No. and capacity of Pressure Vessel – 1 Nos. x 450 Ltrs Set 1
Model :- DPV 10-70 , 3 Kw

392 2 Soft Water Pump

Page-93 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

Providing,fixing, testing & Commissioning of horizontal split casing multistage centrifugal


pumping set with stainless steel SS-304 stage casing and SS-304 impellers with
stainless steel SS-304 shaft as per IEC standards and GJL250 cast iron suction & discharge
casing, connected to TEFC ventilated induction motor of 2 pole, 2900 RPM, suitable for
400/440 Volts, 3 phase, 50 Hz A.C. supply with pressure gauge and with gunmetal isolation
cocks, vibration elimination pads etc. complete with base and frame, nuts and bolts and
necessary RCC foundations as per requirement as per instructions and pump shall have
following duty:
No. of Pumps: 2 (1 Working + 1 stand by)
Capacity : app 50 lpm per pump
Head : app.30m Each 2
Model :- DPVE 2-60 , 0.75 Kw

393 3 Garden Hydrant Pumps

Providing,fixing, testing & Commissioning of Horizontal split casing multistage centrifugal


pumping set with stainless steel SS-304 stage casing and SS-304 impellers with
stainless steel SS-304 shaft as per IEC standards and GJL250 cast iron suction & discharge
casing, connected to TEFC ventilated induction motor of 2 pole, 2900 RPM, suitable for
400/440 Volts, 3 phase, 50 Hz A.C. supply with pressure gauge and with gunmetal isolation
cocks, vibration elimination pads etc. complete with base and frame, nuts and bolts and
necessary RCC foundations as per requirement as per instructions and pump shall have
following duty:
No. of Pumps : 2 (1 Working + 1 stand by)
Capacity : app. 350 lpm
Head : app. 30 m Each 2
Model :- DPVF 32-20 , 4.0 Kw

394 4 Pressure Filter (Domestic Water)

Providing,fixing, testing & Commissioning of vertical Dual Media Pressure Filter (comprising
of 300mm bed depth of graded sand gravel and 600mm bed depth of Anthracite and min.
900mm freeboard) fabricated from high performance M.S plate of minimum 10mm thick for
shell & 12mm thick for dished ends (Quality of steel as per IS:2002 Grade A, Fabrication to
be as per IS:2825) having perforated bed-plate (14mm Thick) collection system complete
with initial charge of filter media, M.S face piping, valves, accessories, painting, testing and
commissioning complete. (Tested to 6 kg/m2)
Discharge : 45,127 lph per filter

Page-94 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

Filtration Rate : 17,500 lit./m2/h


Suggested dia app. : 1.35 m Each 1

395 5 Water Softener

Providing, fixing, testing & Commissioning of ‘Cation’ water softener fabricated as per IS
2825 from minimum 8mm thick MS plate on shell and 10mm thick MS plate on dished ends
complete with initial charge of filter media and resins, face piping accessories, diaphragm
valves, HDPE Brine tank of min. 250 Liters with electrically operated stirrer, piping testing and
commissioning complete with resins of approved quality and make and regeneration
assembly complete with valves, ejector, brine suction valves and piping. (Bidder must
indicate type and quantity of resin used and quantity of salt required per regeneration). All
internal parts of the softener shall be epoxy coated as per approved specifications.
Minimum expected rate of flow: 12500 lph

Total soft water to be produced between two regenerations: of 8 Hours app 100 KL

Expected raw water hardness : app. 300-400 ppm

Expected treated water hardness: less than 5 ppm


Max. working pressure : 4 kg/cm2 Each 1

Providing,fixing, testing & Commissioning of FRP salt saturator as per requirement and
externally painted with suitable anti-corrosive paint, with all required accessories for holding
and supplying salt for softener complete in all respects with electrically operated stirrer and
396 6 of capacity 1000 litres. Each 1

Providing,fixing, testing & Commissioning of Sump Pumps for lifting water from drainage
397 7 sumps in plant room & basement

Providing,fixing, testing & Commissioning of compact monoblock dry motor submersible


pumps for suitable rating, with non-clog free flow open impeller, minimum solid handling
capacity of 28mm suitable for operation on 415 volts + 5% -15%, 50 C/s A.C single phase
supply, speed 960/1440R&M including oil chamber, guide wire for lifting & lowering of pump,
M.S. galvanized lifting chain, duck foot bend with following specifications:

Page-95 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

The above pump sets must be supplied complete with following accessories.

Complete piping 100mm dia common delivery upto 5m as per enclosed tentative layout. (The
a) pipe should be preferably CI LA/heavy duty G.I) -- 1 Set

b) 80mm dia sluice valve.-- 2 Nos

c) 80 mm dia reflux valve.-- 2 Nos

Necessary cables from pump set to control panel (position of panel marked in enclosed
d) layout in plant room).-- 1 Set

Electrical switch panel having all necessary accessories & safety devices of standard
e) specifications. (Panels with sump pumps near each sump as per site conditions). - 1 No.

f) Automatic built-up water level controller with necessary length of cable upto control panel.

Motor rating - 1.1KW


Discharge - max. 15 m3/hr.
Total head - 10 m
Make - KSB
(Complete set as above with 2 nos. pumps) Set 4
DP Make Pumps model DVV 20-3V

Providing,fixing, testing & Commissioning of G.I. pipes (IS:1239 heavy class) complete with
GI fittings ie tees, elbows, sockets, clamps etc including painting of approved specifications,
MS structural supports and hangers as required (as per approved shop drawings) as per
398 8 instructions of Engineer-In-charge.
a) 150mm dia Metre 50
b) 100mm dia Metre 25
c) 80mm dia Metre 40
d) 65mm dia Metre 25
e) 50mm dia Metre 50
f) 40mm dia Metre 40

Page-96 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

Providing and fixing standard G.I. flanges, (only in valves, strainers, expansion joint and
pumps matching flanges) screwed or welded complete with 1.5mm thick compressed
asbestos gasket, nuts, bolts and washers etc., complete including testing of joints. The
399 9 flanges shall be as per I.S:6392 - 1971 table E.
b) 150mm dia Each 4
c) 100mm dia Each 12
d) 80mm dia Each 5
e) 65mm dia Each 5
f) 50mm dia Each 4

Providing and fixing rubber expansion joints (to provide relief from stresses at pipe flanges)
400 10 as per specification of the manufacturers i.e. M/s Kanwal Industrial corporation,
a) 150mm dia Each 4
b) 100mm dia Each 5
c) 80mm dia Each 5
d) 65mm dia Each 4
e) 50mm dia Each 8

Providing,fixing, testing & Commissioning of C.I double flanges suction “Y” type including,
401 11 nuts, bolts and 3mm thick rubber insertion complete.
a) 150mm dia Each 2
b) 100mm dia Each 1
c) 80mm dia Each 1
d) 65mm dia Each 2

Providing,fixing, testing & Commissioning of butterfly valves, wafer end type class PN 1.6 as
per I.S:13095 or BS:5155, including necessary nuts, bolts, gaskets etc. complete (without
402 12 gear box)
a) 65mm dia nominal bore. Each 8
b) 80mm dia nominal bore. Each 6
c) 100mm dia nominal bore. Each 4
d) 150mm dia nominal bore. Each 6

Providing,fixing, testing & Commissioning of forged brass lever operated ball valve of full
flow with forged brass ball (Machined to mirror smooth finish with hard chrome plated) and
spindle with setting and gland of superior quality having minimum working pressure of 10
403 13 kg/cm2 etc. complete in all respect.
a) 40mm dia Each 10

Page-97 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

b) 50mm dia Each 8

Providing,fixing, testing & Commissioning of gunmetal non-return valves vertical or


404 14 horizontal tested to 20 kg/cm2 as per IS:778.
a) 50mm nominal bore Each 4
b) 65mm nominal bore Each 4

Providing, fixing, testing & commissioning of CI double flanged horizontal/vertical type non -
return valve including nuts, bolts, 3mm thick rubber insertions complete to IS:5312, Part-I,
405 15 swing type, class PN 1.6
a) 80mm nominal bore Each 8
b) 100mm nominal bore Each 4
c) 150mm nominal bore Each 2

Providing, installing, testing & commissioning of motor control centres fabricated from 16
gauges MS sheet with powder coated finish. The control panels should be comparable with
406 16 HP of the motor as specified.

(A) Panel - A
For domestic water relift pumps, soft water pump and raw water pump, auto chemical doser
sump pump etc. in plant room.

a) One incoming main isolation MCCB of required rating.

b) Fully taped aluminum bus bar of required capacity in a separate bus bar chamber.

Isolation switch units with MCCB of required rating, for all Hydro-pneumatic pump control
c) panels, + each unit as per details below

Fully automatic DOL starter with push button and ON/OFF indicating lights for each unit,
d) for following requirements:

i) Raw water filter feed pump 3 Nos. (2 working +1 standby) of required H.P.

ii) Garden pumps 2 Nos. (1 working + 1 stand by) of required HP

iii) Soft water supply re-lift pumps 2 Nos. (1 working + 1 standby) of required HP

Page-98 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

iv) Auto chemical doser of 2 no of 0.5 HP capacity (1 working + 1 standby)interlocking with


raw water pumps of required HP

v) Hydro pumpsets (4 sets) --- only connections to each individual Hydro Built-up Control
Panel.

v) Sump pump (8 Nos.) --- only connections to built-up panel.

e) Rotary switches for auto/manual ON/OFF operations for each unit.

f) Rotary duty selector switches.

g) Panel type voltmeter 150mm with rotary selector switch for reading voltage between phases.

h) Panel type ammeter 100mm square. One for each motors with appropriate range.

i) Neon phases indicating lights on the incoming mains.

j) Single phase preventor for each motor.

k) CT Operated Relay

All internal wiring colour coded from incoming mains to various switchgear, starter, meter,
l) indicating lamp and bus bar. All the cable entry to the panel shall be from the top.
(All for above from item (a) to (l) complete set). (The shop drawing to be prepared and
approved before fabrication) Set 1

Providing,fixing, testing & Commissioning of motor pump controller cum water level
407 17 indicating panel in powder coated sheet metal box in 16 gauges M.S including the following:

i) Electronic water level controller working on magnetic type sensing probes.

ii) Electronic minimum 5-level indicator with magnetic type sensing probes.

Page-99 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

iii) Arrangement of alternate switching mechanism for operational and standby pumps.

(A) For Water level indicators with following details:


i) Underground tanks

Minimum 5 level Multi level indicators with magnetic type sensor probes complete. Each 4

ii) Overhead tanks


Solenoid valve operated level controller with magnetic type sensor with minimum 4 level. In
addition to above heavy duty float valve Each 8

For water level controllers with electronic sensing probe complete in all respect for following
(B) functions.

i) Tubewell Pumps

To start at low level in RW tank and to cut off at high level in raw water tank. Set 2

ii) Soft Water Relift Pumps (1 w+1 s)


To start at low level in soft OH tank, and to cut off at high level in soft OH water tank and to
cut off at low level in UG soft water tank. Set 1

iii) Raw Water Pumps (2 w+1 s)

To cut off at low level in raw water UG tanks and to cut off at high level in UG Domestic and
soft water tank and to cut on at low level in domestic & soft water UG tanks. Set 1

iv) Garden Hydrant Pump (1 w + 1 s)


To cut off at low level in U.G Raw water tank Set 1

Providing,fixing, testing & Commissioning of heavy duty copper armored cables 1.1 KVA
grade including necessary support clamps at ceiling level and connection legs complete in all
408 18 respects.

a) Control cable 6 core 1.5 mm2 Metre 150

b) Control cable 2 core 1.5 mm2 Metre 100

Page-100 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

Providing,fixing, testing & Commissioning of heavy duty Aluminium armored cables 1.1 KVA
grade including necessary support clamps at ceiling level, connection lugs and double
409 19 compression glands, complete in all respects.
a) Power cable 3 core 6 mm2 Metre 200
c) Power cable 3 core 10 mm2 Metre 90
c) Power cable 3 core 16 mm2 Metre 150
d) Power cable 3 core 25 mm2 Metre 80
e) Power cable 3 core 70 mm2 Metre 60
f) Power cable 3 core 95 mm2 Metre 25

Providing,fixing, testing & Commissioning of GI earthing wire 8 gauge from all motor and
MCC panel to be connected in as approved manner to the general earthing system complete.
410 20 Metre 425

Providing,fixing, testing & Commissioning of GI earthing strip of size 25x 3mm for higher size
motors and MCC panels to be connected in as approved manner to the general earthing
411 21 system complete. Metre 350

Providing earthing station for pumps and MCC panel including excavation, C.I. manhole
412 22 cover and frame complete as per specifications and I.E. rules. Each 1

Providing and fixing MS slotted cable tray supported from ceiling at intervals of 60cms on
both ends including cable clips with nuts and bolts welding of support rods with ceiling inserts
413 23 or through dash fasteners cutting and making good complete including painting of cable tray.
a) 300mm wide x 40 x 2 mm Metre 210
b) 150mm wide x 40 x 2 mm Metre 150

Providing and fixing electrical solenoid valves in SS body, for min. working pressure of 10
414 24 kg/cm2, complete with all necessary accessories and electrical devices.
a) 65 mm dia. Each 4
b) 50 mm dia. Each 4
c) 40 mm dia. Each 4

Page-101 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

Providing,fixing, testing & Commissioning of automatic chemical dozing system consisting of


electronic dosing pump, suitable to doze chemical solution as per requirement with a dosing
capacity of (0-12 lph) for dosing of appx. 2 ppm of chemical to a flow of water of 50,000 to
100,000 lph. against a pressure of 50-60 psi complete with FRP moulded solution holding
415 25 tank of 100 litre with all standard accessories. Each 1

Providing,fixing, testing & Commissioning of of Pressure Gauge in SS-316 (glycerine filled)


for min. 0-300 psi round dial of 100mm size with threaded nipple, unions, coupling etc
416 26 including standard fittings. Each 10

4 MISCELLANEOUS

Providing and fixing insect-proof coupling to vent pipes of underground tank with threaded or
417 1 flanged joints, including MS flanges, nuts, bolts, 3mm thick rubber insertions complete.
a) 80mm dia Each 4
b) 100mm dia Each 4

Providing and fixing CI double flanged equilibrium float valve with MS lever high pressure,
418 2 copper ball and flanges including nuts, bolts, 3mm thick rubber insertions complete.
a) 40mm dia Each 4
b) 50mm dia Each 4
c) 65mm dia Each 2

Providing and fixing extra heavy duty 560mm dia, double seal, water tight cast iron manhole
cover and frame for placing over the underground water tanks with lifting and locking
arrangements as per approved sample, complete in all respect including fixing in PCC as per
419 3 site requirement. Nos 10

Page-102 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

Providing orange colour safety foot rest of minimum 6mm thick, plastic encapsulated as per
IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as
23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum
112mm space between protruded legs having 2mm tread on top surface by ribbing or
chequering besides necessary and adequate anchoring projections on tail length on 138mm
as per standard drawing and suitable to with stand the bend test and chemical resistance test
as per specifications and having manufacturer's permanent identification mark to be visible
even after fixing, including fixing in manholes with 30x20x15cm cement concrete block 1 : 3 :
6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20mm nominal size) complete as per
420 4 standard design. (In UG & OHT) Each 250

Supply & fixing of 2 hours Fire Rated door system for Stability, Integrity and Insulation criteria
as per IS 3614 Part-2 and BS 476 Part 22 for single and double leaf doors duly tested from
CBRI Roorkee or from laboratory approved by Engineer in Charge with Hardwood Door
frame of section 145mm x 70mm with heat activated intumescent fire seal strip of size 10mm
x 4mm ( Astroflame U.K./Abesco ) and one coat of anti-termite fire retardant Primer alongwith
55mm thick asbestos free composite fire / smoke check wooden shutters of 120minute fire
rating comprising of two 9mm thick Starpan type of Calcium Silicate Boards, a 100% without
Asbestos, Brucite and Meerschaum, having density not more than 1150 kg/m³ and thermal
conductive 0.14 W/m*K sandwitching 31mm thick fire resistance insulation filler coated with
FR silicon sealant and faced with 3mm thick commercial ply facing on both side with heat
activated thick commercial ply facing on both side and heat activated intumescent fire seal
strip of size 10mm x 4mm ( Astroflame U.K/Abesco ) mounted in the grooves of hardwood
lipping on all sides except bottom. The intumescent sealant is used to fill the gaps between
board and internal wooden lipping, Assa-Abloy's Lockwood Model No.2024/Dorma TS-72
Door-Closers / D-Line, Lockwood D-Type S.S Handle minimum 19mm dia 200mm long /
421 5 Dorma Series / D-Line Series and S.S Ball Bearing Hinges of 304grade size 4'' x 3'' mm. sqm 340

Total Price of Section D

SECTION E- SEWAGE TREATMENT PLANT


NOTE : THE TENDER FOR THIS WORK IS ON THE BASIS OF LUM SUM TURNKEY BASIS. CONTRACTOR MUST INCLUDE ALL ITEMS THAT ARE NECESSARY AND
ESSENNTIAL TO PROVIDE A COMPLETE WORKING PLANT TO THE SATISFACTION OF ENGINEER IN CHARGE.THE BOQ GIVEN HEREAFTER IS ONLY FOR THE

Page-103 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

PURPOSE ASSESSING THE OVERALL COSTING OF THE PROJECT AND WILL BE USED FOR ARRIVING AT THE PAYMENT SCHEDULE TO THE CONTRACTOR.
422 1 Preliminary Works
1 Shop Drawings.

1.1.1 Detailed GA drawing, flow diagram, equipment list, power load requirement Job 1

Design, calculations of all elements of the plant, electrical and mechanical work to satisfy
1.1.2 adequacy of design Job 1

Submission of detailed GOOD FOR CONSTRUCTION' stage architectural, structural,


1.1.3 construction, electrical, mechanical and piping drawing for approval. Job 1

2 SEWAGE TREATMENT PLANT

Design, Supplying, Installing, Testing & Commissioning of Sewage Treatment Plant capacity
2 X 200 KLD. The plant proposed shall be 400 kld . with a common pump room. The
plant is proposed to be installed in the basement accessible from the pump room itself
for future maintenance. No opening shall be provided on main slab above for this
purpose, for the following :

Nature of effluent - Domestic Sewage from Toilet use and kitchen waste.
Daily average flow - 400 Cum / Day
pH - 7.5 - 8.5
BOD5 - upto 250-350 Mg/L
S. Solids - 250 - 400 Mg/L
COD - upto 450-600 Mg/L
Oil & Grease - 50 Mg / L
Effluent discharge standard after treatment
pH - 6.0 - 8.5
BOD5 - Less than 20 Mg/L
S. Solids - Less than 10 Mg/L
COD - Less than 100 Mg/L
Oil & Grease - Nil

Sewage treatment plant shall include the following items:


Screen Chamber
Sewage equalization tank/sump
SAFF tank
Secondary Settling tank
Chlorine contact tank
Treated Water tank

Page-104 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

Sludge Holding Tank


Filtration through MGF & ACF
Air Blowers, Pumps & equipment
Piping, valves etc
Electrical Panel & Cabling
Common plant room adjacent to STP.
Softener as optional
Soft water tank as optional
All piping, valves & level indicator/controller etc. within plant room.

Supply, installation, testing & commissioning of 2 Nos Stainless Steel Perforated Screen with
423 2 suitable lifting arrangement (size 600 mm wide x 400 mm high approx) Set 2

Supply, installation, testing & commissioning of electronic type level indicator and controller
for automatic operation of the system with high/low level alarm complete with auxillary
424 3 NO/NC contacts. Set 1

Contractor shall ensure submission of detailed GA drawings (Plan & Section), P & I diagram,
schematic diagram for the above mentioned components and additional components such as
inserts, puddle flanges, vent pipes etc. if so required for the complete work.

Inlet/Outlet Regulating Gates

Inlet regulating gates fabricated form 16 gstainless steel sheets and angles with sturdy lifting
425 4 arrangements for open position. (Size as per vendor's design)
a) On Equalization Tank Inlets Each 2
b) On Aeration tank inlet /oulet launder
c) On Settling Tank Outlet

Supply, installation, testing & commissioning of non clogging type pumps, having SS casing
& SS impeller complete with all accessories, motor of required capacity. Delivery header with
isolation valve, pressure gauge on delivery line with isolation cock level controller with wiring
426 5 to control the level of sump automatically. Pump shall have following duty.

5.3.1 Submersible Sump Pumps (1 Nos. - 1 working & one standby) :-


(Solid handling cap. 40 mm)
Flow rate (each) = 10-12.0 m3 / hr
Head = 8-10 Mtr Set 2

5.3.2 Plant room sump pump 2 Nos (1 working + 1 standby)

Page-105 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

Flow rate = 10.0 cum/hr


Head = 10 Mts Set 1
(Solid handling size for this pump shall be 15 mm).

5.3.3 Sludge re-circulation Pumps (2 Nos. - 1 working & one standby) :-


(Solid handling cap. 40 mm)
Flow rate (each) = 10-15 m3 / hr
Head = 8-10 Mtr Set 1

Cost shall be inclusive of PVC flexible Hose pipe ( for piping submeged in effluent) with M S
epoxy piping (for piping non-submerged in effluent)

Provision of guide ropes to guide submersible pump from upper level to operational level in
sump basin with channels/angle section of MSEP shall be made by the STP contractor.

427 6 Air diffusion system shall include the following:

Twin type rotary air blowers (one working & one standby) capable of delivering 200 cum/hr
(each) of free air at 0.5 kg/cm2 driven through “V” belt or directly coupled through flexible
coupling to a TEFCmotor of suitable HP Suitable for 415 ± 10% volts, 3 phase, 50 cycles a/c
supply Set 2

Air piping shall comprise of pipes droppers/laterals with M S (epoxy coated) Header complete
with all fittings such as tees, crosses, plugs, sockets, elbows, reducers, supports & clamps,
428 7 puddle flanges etc cutting chases & making good. Lot 1

Non clog type air dispersion system capable of handling 3-5 cfm of air with oxygen transfer
efficiency of 3-4% per/ meter water depth. Air dispersion grid shall be assembled in modular
429 8 form so that they can be replaced/repaired
Fine bubble diffusers
a) For equalization tank -2 Nos. Lot 2
b) For sludge holding tank - 1 No. Lot 1
c) SAFF reactor tank- 2Nos. Lot 2
Air dispersion system shall be provided for Equalisation Tank, Sludge holding Tank and
Note : SAFF reactor Tank.

Providing and fixing all piping (as described below) and isolation control valves for making
430 9 the system complete.
SS 304 :Submerged air piping
MS Epoxy : Air piping

Page-106 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

PVC piping :Pumped effluent & tank overflow pipe line Job 1

Supply, installation, testing and commissioning of PVC bio deck SAFF media to be installed
in SAFF Tanks and PVC tube deck settling media to be installed in secondary settling Tank
431 10 alonwith suitable sludge removal arrangement either by pumps or air lifting pumps Job 2

Supply, installation, testing & commissioning of Chlorine dosing system comprising of 100 ltrs
432 11 HDPE/FRP tank with 0-5 lph electronic metering type pump. Set 2

Supplying, installing, testing & commissioning of centrifugal filter feed water pumps SS
body, SS Impeller with mechanical seal along with motor. Pressure gauge with isolation cock,
NRV, Isolation valve on delivery line. Isolation valve, stainer at suction. The pump shall be
433 12 suitable for 415 ±10% volts, 3 phase, 50 cycles AC supply
Capacity : 10-12.0 m3/hr.
Head : 30 M
No. of Pumps (1 working + 1 standby) Set 2

Operation of pump shall be based on level controller proposed to be installed in tank as per
site location. The contractor to ascertain the Head required for pumps as per site conditions
Note: and provide accordingly.

Supplying, installing, testing and commissioning of MS vessel filter with frontal piping and
associated valves and accessories. Filter shall be suitable for minimum working pressure
434 13 of 5 kg / cm2 and shall include media, standard fittings like pressure.
13.1 Multigrade pressure sand filter media
Flow rate : 12.0 m3/hr
Filteration velocity : 15 m3/hr/m2
Filter Diameter : 1000 mm. Set 2

13.2 Activated Carbon Filter


Flow Rate : 12.0 cum/hr
Filteration velocity : 12 cum/hr/sqm
Filter Diameter : 1200 mm Set 2
Contractor may be asked to alter the number of filters and pumps subject to any revision to
Note : meet the desired capacities.

Page-107 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

Approval from pollution board at initial & various other stages of works including preparation
of report / drawings as per pollution board requirement, arrangement of raw sewage for
testing & commissioning. Contractor shall include the cost of all chemicals (consumed during
testing & commissioning and the cost of such items of works which are not explicitly
mentioned above, but are mendatory to have pollution board approval. Nothing extra shall be
435 14 payable in this regard. Job 1

Supply, installation, testing & commissioning of water softening plant (MS) for making up of
water for cooling tower comprising of multiport valve with brine ejection and plastic piping
complete with brine tank with fitting & brine fitting filtering media and complete charge of
436 15 cation exchange resine as given below

Water Flow : 10.0 m3/hr for 10 hr.


(Incomming Hardness 300mg/lit (Approx))
Working Pressure 3.0 Kg/Cum
Outgoing hardness less than 50 ppm
Water Softening plant as described above Set 2

Supply, installation, testing and commissioning of Filter Press of plate size 24"x 24" x 24 nos
plate with screw feed pumps for required capacity (1 working+1 standby), with
437 16 interconnecting piping and poly dosing system all complete. Set 1

Supply, installation, testing & commissioning of centrifugal horizontal / vertical irrigation


water supply pumps with SS Body, SS Impeller with mechanical seal along with motor.
Pressure gauge with isolation cock, NRV, Isolation valve on delivery line. Isolation valve,
stainer at suction. The pump shall be suitable for 415± 10% volts, 3 phase, 50 cycles a/c
438 17 supply
Capacity : 25 m3/hr.
Head : 45 M
No. of Pumps (2 working + 1 standby) Set 1

Supply, installation, testing & commissioning of centrifugal horizontal/vertical soft water


booster pumps for cooling towers of with SS Body, SS Impeller with mechanical seal along
with motor. Pressure gauge with isolation cock, NRV, Isolation valve on delivery line. Isolation
valve, stainer at suction. The pump shall be suitable for 415 ±10% volts, 3 phase, 50 cycles
439 18 A/C supply required.

Page-108 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

Capacity : 10 m3/hr.
Head : 30 M
No. of Pumps (1 working + 1 standby) Set 1

3 ELECTRICAL INSTALLATION FOR STP

Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of


motor control centre fabricated out of 14 gauge CRCA sheet steel. Cable gland plates shall
be provided on top as well as at the bottom of the panels. Panels shall be treated with all
anticorrosive process before painting as per specifications with 2 coats of red oxide primer
and final approved shade of powder coated paint. 2 Nos. earthing terminals shall be provided
for 3 phase, 4 wire, 50 Hz supply system. Lifting hooks shall also be provided in case of large
panels. Approval shall be taken for each panel before fabrication. Quoted rates shall be
inclusive of cables (in accordance to specification) with earthing from panel to each
440 19 motor/equipment.
Motor Control Centre
Incoming
200 amps TPN MCCB with the following accessories:
a. 0-500 volts 96 x 96 mm square electronic voltmeter with selector switch shall be protected
by 2 amps TP MCB. 1 Set
b. 0-100 amps 96 x 96 mm square electronic ammeter with selector switch and 100./5 amps
10 VA CL:1 CTs. 1 Set

c. Phase indicating lamps shall be protected by 2 amp SP MCB 3 Sets


Bus Bar

300 amps TPN (15 KA) copper bus bar with heat shrinkable insulation sleeves.

a. Required Nos of required capacity TPN MCB for direct on line starter/star delta starters
and out going feeders to all the pumps/blowers etc. (including standbies). Each compartment
shall contain auto / manual selector switch and indicating lamp with MCB’s for
‘ON/OFF/TRIP’ status of motor
b. Spare MCB’s of following capacities:
i. 32 amps TPN MCB’s 3 Nos.

c. Necessary cable alleys, internal / cabling, wiring, cabling from MCC to various pumps /
equipment and interlocking, earthing for all equipment shall also included
a. All MCCBs / MCBs shall be of 15 KA breaking capacity and suitable for motor duty
Notes : application.
b. All motor starters shall be provided with Automatic level controller

Page-109 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

c. DOL starters shall be used for mototrs below 10HP and Star-Delta Starters for other
motors .

d. Provision shall be made for providing potential free contacts to all pumps starters
MCC for all STP equipments/pumps as described in sub head II Job 1

Total Price of Section E

SECTION F- AUDIO VISUAL SYSTEM


A) AUDIO VISUAL EQUIPMENTS

Supply, installation, testing & Commissioning of 3 Chip DLP Projector, Resolution (Native /
Max) , WUXGA (1920 x 1200) , Display Type 0.67" DLP x 3 , Aspect Ratio 16:10 (Native)
,Brightness 6000 ANSI Lumens , Contrast Ratio 2000:1 , ,Connectivity Inputs 1 x HDMI/DVI ,
1 x Composite , 1 x S-Video , 1 x RGB D-Sub 15pin ,Control 1 x RS-232, Lens Shift Vertical:
+/- 100% ,Horizontal: +/- 30% ,Brightness Uniformity 95% , complete as per the
specifications, complete with hardware for mounting in ceiling including all accessories
required for mounting as required. [Approved Make : Barco / Christie/ Digital Projection]

441 1 each 2

Supply, installation,testing & Commissioning of Zoom Lens with throw ratio of 2.0 - 4.0 :1 ,
Powered Zoom / Focussing complete as per the specifications, complete as required.
442 2 [ Approved Make : Barco / Christie / Digital Projection] each 2

Supply,installation,testing & Commissioning of 3 Chip DLP Projector, Resolution (Native /


Max) , WUXGA (1920 x 1200) , Display Type 0.67" DLP x 3 , Aspect Ratio 16:10 (Native)
,Brightness 12000 ANSI Lumens , Contrast Ratio 1700:1 , ,Connectivity Inputs 1 x HDMI/DVI
,1 x Composite , 1 x S-Video , 1 x RGB D-Sub 15pin ,Control 1 x RS-232, ,Lens Shift Vertical:
+/- 100% ,Horizontal: +/- 30% ,Brightness Uniformity 95% , complete as per the
specifications, complete with hardware for mounting in ceiling including all accessories
required for mounting as required. [Approved Make : Barco/ Christie/ Digital Projection ]

443 3 each 1

Page-110 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

Supply,installation,testing & commissioning of Zoom Lens with throw ratio of 4.0 - 6.0 :1 ,
Powered Zoom / Focussing complete as per the specifications, complete as required.
444 4 [ Approved Make : Barco / Christie / Digital Projection] each 1

Supply, installation, testing & commisioning of wall/ ceiling mounted Matte white motorized
projection screen with tubular ( Non lubricant motor, 3 steps control position, LVC interface
for control) including required suspenders, brackets complete as required at site matt white
finish view area. Fabric shall be flame retardent and mildew resistant, remote controlled
operation of the screen, parallel touch panel control. A straight rigid tubular metal header
more than 75mm in diameter with black masking 450mm at top and 900mm at bottom.
445 5 Approved Make- Draper/ Dallite/ Harkness.
a) 8850mm X 5500 mm (H) each 1
b) 4480 mm X 2800 mm (H) each 2

Supply, installation, testing & commisioning of Architectural/ Video Interface Panel. Table top
architectural panel with pneumatic mechanism. Compatible to current computer video
sources of vrying resolution. RGBS,
RGsB, HDTV, component video, S-video and composite video signals. Video and Audio
output-5 Female BNC fir RGBHV/ 15 Pin HD & 3.5 mm mini connector. 300 MHz video
bandwidth. RS 232 control, Horizontal Shift control. Floor mount/ wall mount as required at
site. Accessories like floor junction box included in the scope of work.
Approved Make- Extorn HAS 400 + Extender AAP/ Altinex-
446 6 TNP121 or equvalent as approved. each 3

Supply, installation, testing & commissioning of Video Data Switcher cum scaler with 2
composite video , 2 S-video ,1 component video (interlaced, progressive, or HDTV) , 2
RGBHV, RGBS, RGsB ,1 DVI-D digital video (single link) Inputs , Resolution range 640 x
480 to 1920 x 1200, 480p, 576p, 720p, 1080i, and 1080p ,Scaled Output Resolution upto
1920 x 1080 , complete with 19'' rack mounted as per the specifications, complete as
447 7 required.[Approved Make : Extron - IN 1508 / Kramer - VP 729 ] each 3

Page-111 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

Supply,installation, testing & commissioning of Touch Control System with 8.4” WiFi
Touchpanel , 800 x 600 resolution , 16-bit Isys i/O graphics , Synapse image rendering
algorithm ,802.11a/b/g Wi-Fi 2-way wireless communications , with Ethernet Processor &
required IR Probes to control the Audio Visual system . [Approved Make : Crestron - TPMC
448 8 8X / AMX - 8.4 Modero View Point] each 3

Professional grade DVD Player- Supply, installation, testing & commissioning of Professional
grade rack mounting DVD player compatiable for play back of DVD audio CD and Video CD
formats, including CR, CD-RW MP3 etc; dual discrete optical lasers with MPEG 2 decoding
and 32 bit processor, video resolution>500 TV lines, Audio frequency response within 0.5dB
from 2Hz to 40000Hz. Signal to noise ratio better than 110dB, composite video and S-video
outputs 1V p-p, 75 ohms, Audio outputs 1 V rms, 6 channel for Dolby Digital and LR streo
outputs, Video output RGBHV (through built in or external converter.) Approved Make-
449 9 Denon DNV 100/ Tascam DV-D6500/ Harmon Kardon 31. each 3

Supply , installation , testing & commissioning of Interactive Electronic Board with over all
size of 7'8'' X 2'9'' (100" diagonal) with software and Set of pens , Including short throw
projections system with bracket for mounting complete in all respects , complete as
450 10 required . [Approved Make :Team Board / Smart Board / E-Learn/ QDMA ] each 2

Supply, installation, testing & commissioning of Communication Camera with 1/4" CCD with
340,000 effective pixels , Pan/Tilt/Zoom camera with 9 preset positions ,26x Optical Zoom
with powered telephoto lens , Built-in Infrared illuminator ,Cascade control facility for up to 9
cameras Composite BNC (RCA with included BNC/RCA connector),S-video (with included
VC-EX3 adapter) Pan Angle Range ±100° (Standard) / ±170° (Reverse) , Tilt Angle Range
+90°/-30° (Standard) / +10°/-90° (Reverse) , TV Lines 420 , SNR 48 dB , Horizontal Field-of-
View 3 to 47.5 degrees (65 degrees with wide angle lens adapter) , White Balance Auto
,Exposure Auto/Manual ,Focus Auto/Manual ,Focus Length 3.5 to 91mm, f/1.6 to 4.0 , Pan
Speed 1 to 90 degrees/sec .,Tilt Speed 1 to 70 degrees/sec ,Control RS232 serial as per the
specifications, complete as required.[Approved Make : Canon / Panasonic / Elmo.]
451 11 each 3

Page-112 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

Supply,installation,testing & commissioning of Video Conferencing System HD ( Upto 4


sites ) with BANDWIDTH H.320 up to 384 kbps , H.323 up to 1.1 Mbps ,SIP up to 1.1
Mbps ,VIDEO STANDARDS H.261, H.263, H.263+, H.263++ (Natural Video), H.264 , H.261,
H.263, H.263+, H.263++ (Natural Video), H.264 , IP NETWORK FEATURES - IEEE
802.1x/EAP Network Authentication ,H.235 Gatekeeper as per the specifications, complete
452 12 as required. [Approved Make : Polycom / Tandberg / Lifesize ] each 3

Supply & drawing of single conductor 20AWG Non plenum Video Cable, in the conduit /
453 13 raceway etc. complete as required.[ Approved Make : Extron / Kramer / Belden.] metre 400

Supply & drawing of two conductor 26AWG Non Plenum S-Video Cable, in the conduit /
454 14 raceway etc. complete as required.[ Approved Make : Extron / Kramer / Belden.] metre 350

Supply & drawing of RGBHV Cable, in the conduit / raceway etc. complete as required.
455 15 [ Approved Make : Extron / Kramer / Belden.] metre 500

B) SOUND REINFORCEMENT SYSTEM


SUBHEAD - I MICROPHONES- WIRELESS AND WIRED

Supply, installation, testing and commissioning of Wireless microphone system handheld with
transmitter and rack mount receiver unit UHF frequency range, Dynamic cordiod polar pattern
microphone signal to noise ratio> 60dB, frequency response 100 Hz to 17000Hz, true
diversity antena, complete with adapter, batteries and rack mount kit for the receiver.
456 1 Approved Make- Shure SLX(SM58)/ AKG WMS450 (D-5)/ Sonheisser. each 4

Supply, installation, testing and commissioning of wireless microphone system- Lavalier


microphone with transmitter and 19'' rack mountable receiver UHF frequency range, omni-
directional polar pattern microphone, signal to noise ratio> 60dB, frequency response 100Hz
to 17000Hz. True diversity antenna complte with antenna distribution system, complete with
adapter, batteries and rack mount kit for the receiver. Approved
457 2 Make- Shure SLX (WL-93)/ AKG WMS 4500(CK 77)/ Sonheisser. each 4

Page-113 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

Supply, installation, testing & commissioning of Power & Antenna Distribution system for
wireless microphones complete as required to allow four diversity receivers to use the same
pair of antenna, rack mountable with inbuilt power distribution, RF signal amplifier, Active
wideband type suitable for UHF frequencies for the above receivers and as per technical
specifications enclosed. Approved Make- Shure UA 844/ AKG PS 4000+ Accessories/
458 3 Sonheisser. each 2

Supply, inatllation, testing & commissioning of Condenser cardioid microphone, Lectern/


Podium for speech, Transducer type: Condenser, Directional characteristics: Cardiod,
Frequency response 100 Hz to 17000Hz, free field sensitivity at 1KHz re: 1V/ microbar:-
52.5dB, output impedence rated at 150ohms, Maximum sound pressure level (1KHz at 1%
THD) 122dB, flexible metallic stem ,minimum 450mm long, connector: 3 pin standard XLR at
end of stem, complete with 6m long cable, mounting hardware for fixing on lecturn/ podium.
459 4 Approved Make: Shure MX 418/C or AKG GN99 H/L. each 1

Supply, installation, testing and commissioning of Dynamic Cardiold Vocal microphone,


handheld complete handheld microphone for leads vocal, Dynamic cardiod polar pattern,
sensityvity 2.5mV/Pa, Frequency response 100 Hz to 17000 Hz, Load Impedence > 150F,
460 5 XLR socket for mounting. Approved Make: Shure SM 58/ AKG D-5. each 6

Supply, installation, testing and commissioning of Wireless microphone system- WHS 450
Vocal Set/C5 (with C5 Mic) including 1X HT450/C handheld with transmitter 1X mic holder
and rack mount receiver unit complete as required. Approved Make: AKG WMS
461 6 450/SHRUE each 4

Supply, installtion, testing and commissioning of Wireless microphone system- WHS 450
presenter set, including 1 X SR450 receiver, 1X PT450 pocket transmitter, 1 X C407L lavalier
wireless microphone with body pack and rack mount receiver unit complete as required
avaliable in following frequency bands and included AC adapters.
462 7 Approved Make: AKG WMS 450/ SHURE each 4

Page-114 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

Supply, installtion, testing and commissioning of Semi-open, circum-aural dynamic stereo


headphone, mini XLR - connector. Approved Make:
463 8 AKG K 240/ SHURE each 2

Supply, installtion, testing and commissioning of Condencer cordiod Microphone with flexible
stem minimum 450mm long lectern/ podium speech goose neck module, XLR connector.
464 9 Approved Make: AKG GN 155+ CK 33/ SHURE each 2

Supply, installtion, testing and commissioning of soundcraft 16 channel mixer with 4 inputs
and 8 outputs complete as required. Approved Make: Sountcraft LX 7ii 16
465 10 ch/ SHURE/ Allen & Heath. each 2

Supply, installation, testing and commissioning of 2X6 Loudspeaker Management systems/


466 11 display. Approved Make: Dbx 260. each 2

Supply, installtion, testing and commissioning of 15'' Two way self powered speaker system,
400 watt LF and 100 watt HF crown class D Amplifiers. DSP featured Input section with
467 12 selectable EQ.15'' Differential Drive woofers. Approved make: JBL PRX 515/ EAW. each 4

SUBHEAD - II REVERB SIGNAL PROCESSOR

Supply, installation, testing & commissioning of Dual channel reverb processor Analouge
Audio Inputs, connectors two 1/4'' TRS balanced or unbalanced, Impedence :20kohms
balanced, 10kohms unbalanced . Approved Make: LEXICON MX 200/dbx/ alesis/
468 1 Equivalent. each 1

Supply, installation, testing and commissioning of Digital Signal Processor network with 4
anlouge & AES/ EBU inputs and 8 analouge & AES/EBU outputs 24 bit A to D and Dto A
coverters, Frequency response 100Hz to 17000Hz, THD < 0.01% (line level), Signal Matrix
Mixer, Automatic feedback suppressor, Graphic/ parametric equilization for each channel,
Digital time delay facility of up to 2 sec. Full function compressor / limiter, phase adjustment
and invert facility, front panel functions and display with security lockout, serial port for
programming. Approved Make:
469 2 DBX4800 Drive Rack/ Biamp Nexia. each 1

SUBHEAD - III POWER AMPLIFIER

Page-115 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

Supply, installation, testing and commissioning of Dual Channel Power Amplifier with
3500Watt per channel at 4 ohm operation, frequency response 20Hz to 20000Hz, Damping
Factor> 5000, siganl to noise ratio> 105dB, Total harmonic distortion<0.1% at 20Hz to 20KHz
protection, full short circuit, open circuit & thermal. Approved Make: Crown MAi 9000/ Crest
470 1 Audio/ QSC each 1

Supply,installation, testing and commissioning of Dual channel power Amplifier with >= 2500
Watt per channel at 4 ohm operation, frequency response 20Hz to 20000Hz, Damping
Factor>5000, signal to noise ratio>105dB, total harmonic distortion <0.1% at 20Hz to 20KHz,
Protection- Full short circuit, open circuit & thermal.
471 2 Approved Make: Crown MAi 5000/ Crest Audio/ QSC each 3

Supply, installation, testing and commissioning of Dual Channel Power Amplifier with >= 800
Watt per channel at 4 ohm operation, frequency response 20Hz to 20000Hz, Damping
Factor>5000, signal to noise ratio>105dB, total harmonic distortion <0.1% at 20Hz to 20KHz,
Protection- Full short circuit, open circuit & thermal.
472 3 Approved Make: Crown XTi 2000/ Crest Audio/ QSC each 1

Supply, installation, testing and commissioning of Dual Channel Power Amplifier with >=
1200 Watt per channel at 4 ohm operation, frequency response 20Hz to 20000Hz, Damping
Factor>5000, signal to noise ratio>105dB, total harmonic distortion <0.1% at 20Hz to 20KHz,
Protection- Full short circuit, open circuit & thermal.
473 4 Approved Make: Crown XTi 4000/ Crest Audio/ QSC each 3

SUBHEAD - IV FULL RANGE LOUDSPEAKER SYSTEM

Supply, installation, testing & commissioning of Main Loudspeaker assembly- Full range two
way speaker system, with passive amplifier operation, frequency response 20Hz to
20000KHz, construction: 1X 15'' LF Driver, 3X1.5'' High frequency exit compression Driver
with Horn, Power Capacity: diffrential drive LF 800W, Nominal impedence: 8 ohms, sensitivity
(1W, 1m):95dB SPL, Nominal dispersion:100o H X 15o V, HF on constant curvature wave
guide. Dual angle pole socket and in ringing Hardware.
474 1 Approved Make: JBL VRX 932 LA/EAW each 8

Page-116 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

Supply, installation, testing & commissioning of wall/ floor mount subwoofer, 18'' bass reflex
subwoofer, Frequency response 20Hz to 20000KHz, Construction :18'' LF differential drive
woofer, Power Capacity 800W/1600W/ 3200W, Nominal impedence: 8 ohms, sensitivity (1W,
475 2 1m):95dB SPL. Approved Make: JBL VRX 918S/ EAW. each 4

Supply, installation, testing and commissioning of Array frame for suspending up to


6VRX932LA, enclousure includes 4 X Quick release pin, 2 X shakleless, 2 X drop levers.
476 3 Approved Make: JBL VRX-AF each 2

Supply, installation, testing & commissioning of Front Fill loudspeaker- 8'' Full range
loudspeaker system comprising of 8''LF and 1'' HF compression low-mid drivers and a horn
loaded HF driver with integral crossover and low profile for front fill. The height of the speaker
should not exceed 550mm, due to avlibility of the space under the stage. Frequency
response 40Hz to 18000Hz, power handling:150W pink, sensitivity (1W, 1m):90dB SPL.
Nominal coverage: 110o X 85o. Approved Make: JBL29 AV
477 4 Control/ EAW UB22Z each 3

Supply, installation, testing and commissioning of Green Room Speaker- Full range two way
speaker system. Monitoring loudspeaker in sealed baffle, suitable for wall mounting,
frequency response 100Hz to 17000Hz, construction5-1/4'' LF Driver, 3/4'' HF driver, Power
handling 150W rms, 30Watt LMT, complete with LMT and wall bracket.
478 5 Approved Make: JBL25T Control/EAWUB12 each 2

Supply, installation, testing and commissioning of Control room speaker - Full range two way
speaker 10'' two way powered speaker system, Frequency response 90Hz to 16000Hz,
Construction 10'' LF Driver, 1'' HF Driver, Power Handling 125W rms, 50Watt HF, complete
479 6 with LMT and wall bracket. Approved Make: JBLEON10G2/EAW each 1

Page-117 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

Supply, installation, testing and commissioning of Effect/ Fold back speaker - Two way full
range active stage moniter speaker system. 12'' two way speaker system, Frequency
response 100Hz to 20000Hz. Construction: 12'' LF Driver, 1.5'' High Frequency, Power
Capacity: LF 350W, HF 100W (continuous/ Long Term), Max SPL 94dB@(1W, 1m). Nominal
480 7 dispersion: 70o H X 70o V. Approved Make: JBL MRX512/EAW each 4

Supply, installation, testing and commissioning of Ceiling speakers- 6-1/2'' LF and 3/4''
titanium coated HF frequency response 100Hz to 20KHz, Power capacity 150W, sensitivity
1W, 1m 89dB, Nominal coverage 110o conical complete with ceiling brackets trim rings etc.
481 8 Approved Make: JBL Control 26CT each 6

SUBHEAD - V AUDIO MIXER & CD/ CASSATTE RECORDER

Supply, installation, testing and commissioning of Audio Mixer 32 Channel-32 mono


microphones/ line inputs, 04 group outputs, Stereo and Mono output, Auxiliary inputs >
4(Balanced) and outputs >2 (Balanced), Frequency response 100Hz to 17000Hz, Total
Harmonic distortion should be<= 0.1%, Equivalent Input noise should be -128dBu, Cross
talks at least -70dB between input channel and also input and output channel, Phantom
power +48V DC, Streo Input Level (max) should be +20dBu, Headphone monitoring socket
complete with AKG 55 Monitoring Headphone.
482 1 Approved Make: Soundcraft GB4 32/ Yamaha each 1

Supply, installation, testing and commissioning of Professional CD/ Cassete recorder combi
Deck RS 232 Control, Pitch Control +/- 12% in 0.1 steps, CD/ Cassete Recorder, CD/ CDRW,
MP-3 player. Approved make: DENON DN-T 625/
483 2 TASCAM each 1

SUBHEAD - VI ACCESSORIES, EQUIPMENT RACK ETC.

Supply, installation, testing and commissioning of Control equipment rack for audio and video
equipment. 19'' floor standing amplifier rack, suitable for all the control equipment for SRS
and AV system with provision for additional 3U blank plate for adding an equipment at a later
date, there shall be provision of at least 1U blank plate spacing between two adjacent
equipment so as to provide sufficient ventilation. Approved Make:
484 1 President/ Rittal each 3

Page-118 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

Supply, installation, testing and commissioning of Patch panel for input/ output circuit each
with 48(2 rows of 24) tip, ring and sleeve jack and 12 Nos. of 450mm long patch cords, rack
mountable with lacing brackets, solder tag connections on rear.Approved Make: Neutrik/
485 2 Switchcraft. each 3

Supply, installation, testing and commissioning of Microphone connector-F-XLR panel mount


486 3 connect. Approved Make: Neutrik/ Switchcraft. each 53

Supply, installation, testing and commissining of Loudspeaker connector- Speak On Female


487 4 panel mount connector. Approved Make: Neutrik/ Switchcraft. each 8

Supply, installation, testing and commissioning of Microphone stand- Floor stand boom type,
powder coated or chrome plated, with heavy base for maximum stability, incorporating shock
488 5 mounting. Approved Make: Ahuja/ AKG. each 6

Supply, installtion, testing and commissioning of Microphone stand- Desk type stands,
powder coated or chrome plated, incorporating shock mounting. Approved Make: Ahuja/
489 6 AKG. each 6

Supply, installation, testing and commissioning of wall/ floor mount junction boxes two way,
construction:16SWG galvanized / powder coated MS sheet, 200mm X 150mm X 150mm,
490 7 wall or floor mount with hinged lids. each 33

Supply, installation, testing and commissioning of Wall/ floor mount junction boxes two way
construction: 16 SWG galvanized/ powder coated MS sheet, 75mm X 150mm X 150mm wall
491 8 or floor mount with hinged lids. each 18

SUBHEAD - VII CABLING AND CONDUITING


Supplying, drawing, testing and commissioning of Microphone cable- 23/.2mm twin twisted
shielded, ATC complete. Approved Make: Belden/ Sommer/ Gotham/
492 1 Delton./ Klotz. metre 1 200

Page-119 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

Supplying, drawing, testing and commissioning of Main Loudspeaker cable for speaker- twin
twisted, two core 2.5 Sqmm Multi- strand typically140 stands of copper 0.15mm dia each,
conductor resistance <4.5 ohm, overall PVC sheath. Approved make: Belden/ Sommer/
493 2 Gotham/ Klotz. metre 950

Supplying, drawing, testing and commissioning of 3core 2.5sqmm main cable.


Approved Make: Belden/ Sommer/ Gotham/
494 3 Delton./Finolex metre 700

Supply, installtion, testing and commisssioning of Loudspeaker cable: Twin twisted two core
495 4 80/.2mm complete. Approved Make: Beldon/ Sommer/ Gotham/ Delton. metre 400

Fabricating and installing following sizes of perforated M.S. cable trays including horizontal
and vertical bends, reducers, tees, cross members and other accessories as required and
duly suspended from the ceiling with M.S. suspenders or fixing on surface and including
painting with powder coating etc. as required. Approved Make:Pilco/ slotco/ Rico steel/
system
steel/ murphy.
496 5
a) 150mm width X 50mm depth X 1.6mm thickness metre 200

SUBHEAD - VIII EARTHING

Earthing with copper earth plate 600mm X 600mm X 3mm thick including accessories and
providing masonary enclosure with cover plate having locking arrangement and watering pipe
497 1 etc.(but without charcoal or coke and salt) as required. each 1

498 2 Extra for using salt and charcoal for G.I. or copper plate earth electrode as required. each 1
Providing and fixing 25mm X 5mm copper strip in 40mm dia G.I.pipe from earth electrode as
499 3 required metre 10
Providing and fixing 25mm X 5mm copper strip on surface or in recess for connections etc.
500 4 as required. metre 50
Providing and fixing 4mm dia copper wire on surface or in recess for loop earthing as
501 5 required. metre 50
Supplying and drawing 2.24mm dia Copper conductor wire loop earthing in the existing
surface/ recessed steel/ PVC conduit/ PVC casing and capping / wood batten along with
502 6 other wires as required. metre 200
Providing and fixing earth bus of 50mm X 5mm copper strip on strip on connections etc. as
503 7 required. metre 1

Page-120 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

Total Price of Section F

SECTION-G - HVAC Work

(A) Centrifugal Chillers


1 WATER CHILLING UNITS

SITC & Handling over Centrifugal type Imported flooded water chilling units of specified
capacity, getting ARI certification at specified conditions, R-134a gas, Full Load acceptance
testing and running in testing, all as per specification, date sheets drawings and as required.
The chiller shall be provided with VFD drive. Chillers shalll be suitable for 415 V, + 10%, 50
504 cycles + 3% 3phase 4 wire supply.
# Type Chilling Unit - Centrifugal
# Compressor - Hermetic / Semi-hermetic / Open
# Compressor - 1 per machine
# TR output-500 TR at specified condition
# Refrigerant - R-134a precharged in factory
# EWT Chiller - 12.770 C (550 F)
# LWT Chiller - 6.660 C (440 F)
# Chiller fouling factor -0.0005 (British Units)
# Condenser EWT - (90 F) / 97.5 F LWT
# Condenser fouling factor-0.001 (British Units)

# IKW / TR at full load at above condition - not more than 0.68 at specified condition
# Chiller Flow rate 1090 usgpm
# Condenser flow rate - 1910 usgpm
Chiller with VFD Drive each 3

Total Of Chiller S/I/T/C including all taxes duties and levies as applicable.

(B) ALL AIR SIDE EQUIPMENT


1 Double Skinned Floor Mounted / Ceiling Suspended Air Handling Units

Page-121 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

Supplying, installing, testing and commissioning of factory built Air Handling units double skin
type with 25mm thick panels consisting of Stainless Stal casing of thickness 0.8mm outside
layer and 0.8mm inside layer with zinc coating and polyurethene foam (PUF) insulation
having density of 42 kg/cum complete forward / backward curved supply air centrifugal fan
which shall be plug type (SWSI) direct driven with VFD suitable for static pressure etc. as
detailed below, chilled water cooling coil with aluminium finned copper tubes (tube thickness
not less than 0.5mm), filter section having minimum 10 micron particle size with an efficiency
of 90% filters, heat recovering wheels for cooling the fresh air, TEFC motor suitable for 415 +
10% volts, 50 Hz, 3 phase AC supply, drain connection with stainless steel drain pan duly
insulated and necessary vibration isolation arrangement to avoid any vibration etc. complete
as per specifications and drawings.

505
The face velocity across cooling coil shall be limited to 152 MPM maxm.The capacity of
Air-handlers shall be as follows:
AHU NO. Capacity in cfm Approx. TR
i SAF G/F 1 5500 10 each 1
ii SAF F/F 2 17800 40 each 1
iii SAF F/F 3 17800 40 each 1
iv SAF S/F 4 17800 40 each 1
v SAF S/F 5 17800 40 each 1
vi SAF T/F 6 19200 45 each 1
vii SAF T/F 7 19200 45 each 1
(The following provisions shall be deemed to be included in the main item).

a Variable frequency drive with bypass arrangement with VFD units.


b Lamp switch.
c Fire retardant flexible joints for outlets of the units.
d Sound attenuation section for low noise.
e Provision for electrically interlocked fan section with access door.

2 SITC & Handling over of factory built floor mounted vertical / horizontal chilled water double
skin type Air Handling Units made of 25mm insulated panels consisting of Stainless Stail
casing of 0.8mm outside and inside layer with factory applied PUF insulation (By injecting
with the help of injection moulding machine) complete with fan section with forward /
backward curved fan, chilled water coil section filter section strip heaters, heating
thermostats, safetystat etc. as per Data sheets, specifications and drawing and as required,
filter - 90% efficency up to 10 micron with VFD Drive.

506
AHU NO. Capacity in cfm Approx. TR

Page-122 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

i PRB G/F 8 4000 each 1


ii PRB G/F 9 7000 each 1
iii THSTI G/F 10 16000 30 each 1
iv THSTI G/F 11 14500 25 each 1
v THSTI G/F 12 28000 50 each 1
vi THSTI G/F 13 28000 50 each 1
vii THSTI F/F 14 28000 45 each 1
viii THSTI F/F 15 28000 45 each 1
ix THSTI S/F 16 28000 45 each 1
x THSTI S/F 17 28000 45 each 1
xi THSTI T/F 18 14500 30 each 1
xii THSTI T/F 19 12000 20 each 1
xiii LIB. G/F 20 11000 30 each 1
xiv LIB. G/F 21 11000 30 each 1
xv LIB. F/F 22 15000 30 each 1
xvi LIB. F/F 23 15000 30 each 1
xvii LIB. F/F 24 15000 30 each 1
xviii LIB. F/F 25 15000 30 each 1
xix RCB G/F 26 13000 30 each 1
xx RCB G/F 27 17500 35 each 1
xxi RCB G/F 28 17500 35 each 1
xxii RCB G/F 29 25000 40 each 1
xxiii RCB F/F 30 17500 35 each 1
xxiv RCB F/F 31 25000 40 each 1
xxv RCB S/F 32 17500 35 each 1
xxvi RCB S/F 33 25000 40 each 1
xxvii RCB T/F 34 18500 35 each 1
xxviii RCB T/F 35 11500 20 each 1

3 SITC & Handing over of ceiling suspended fan coil units complete with double skin insulated
with 25mm PUF cabinet, copper tube aluminium finned cooling coil, three speed motor,
filters, forward curved low noise fan, double insulated drain pain, stripheater for winter
heating, heating / cooling thermostat, regulator for fan speed control, wiring from wall plate to
the fan motor and strip heaters etc. complete as per specifications and as required.

507
i 800 cfm with 2 kw strip heater each 2
ii 1000 cfm with 2 kw strip heater each 26
iii 1200 cfm with 2 kw strip heater each 34

(C) PUMPS

Page-123 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

1 SITC of vertical split case, back pull out type, End suction pump complete with ISMC 125, MS
Channel iron base, Hot dipped galvanised for anti-corrosion, stainless steel hold down bolts
and nuts, tyre type / Lovejoy coupling, TEFC Eff-1 motors, SS coupling guard, brass purge
valves.
508
a CDW Pump Flow - 1910 usgpm / 80 Ft head / 1450 rpm each 3
b Primary CHW Pump Flow - 1090 usgpm / 40 Ft head / 1450 rpm each 3
c Secondary CHW Pump Flow - 1090 usgpm / 80 Ft head / 1450 rpm
each 3

(D) COOLING TOWER


1 SITC of 'Induced draft' cross flow or counterflow, FRP casing, rectangular, FRP integrated
basin (without bolted bottom plate), without rotating sprinkler, PVC fill, PVC eliminator, FRP
adjustable multi-blades fan of cast aluminium alloy, stainless steel hardware, hot water basin
and hot water header, suction sump SS strainer, brass float valve, HDG or extruded
aluminium ladder, TEFC weather proof motor with FRP cover / guard.
Tower Rating (Each Tower) 600 TR
Flow Rate 1910 usgpm (each)
Hot Water 97.50 F
Cold Water 900 F
Wet Bulb Temp. 830 F
(Tower location on the roof of service block/AC plant) Fan Motor Rating 37.5 KW

509 each 3

(E) CONDENSER WATER PIPING


1 SITC of cast iron heavy duty pot strainer of PN-16 rating (one at each cooling tower outlet)
with SS-304 double mesh strainer, dimension of strainer basket minimum 350mm Ø and
500mm height, complete with galvanised nuts and bolts, gaskets, 50 dia butterfly valve for
drain as per specifications and as required.
Flow Rate = 1910 usgpm
Pipe = 300 mm Ø
510 each 3

2 SITC of MS heavy class black pipes for condenser water piping, complete with elbows,
flanges, specials, other fittings and steel supports. All fasteners will be galvanised. Main
header size for 3 x 1910 usgpm as per specifications and as required.
511
a 450 mm Ø (24" Ø) mtr 90
b 300 mm Ø (12" Ø) mtr 120

Page-124 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

3 SITC of Valves (Complete with fittings, Nuts, Bolts & Gaskets (PN-16 Rating).
512
a 300 mm Ø Butterfly Valve each 26
b 50 mm Ø Butterfly Valve each 6

c SITC of C.I. Check Valve double plate type (PN-16) rating, as per specification 300 mm Ø
each
513 3

514 5 SITC of cast steel ball valves (PN-16 Rating) (20 mm Ø). each 12

515 6 SITC of cast steel ball valves (PN-16 Rating) (25 mm Ø). each 6

7 SITC of water pressure gauge (100 mm Ø) bourdon type with brass ball valve of 3/8" Ø and
SS tubing, socket. Range (0-50) / (0-100) as required. each
516 12

8 SITC of Mercury in glass industrial thermometer in SS-304 casing with 0.5 C least count,
range 0-50 C. Brass oil filled thermowell of 1/2" size. each
517 6

(F) CHILLED WATER PIPING


1 SITC of factory pre-insutated 'C" class (heavy duty) M.S. chilled water pipeing with factory
insulation/ jacketing (HDPE/Al/GI) for buried/ indoor application with all necessary fithing like
bands tees, reducers, flanges, joints, sports, excavation, refilling etc. (As per approved
drawings & Specifications enclosed) Main chilled water header to be sized for 3 x 1010
USGPM.

518
a 350 mm Ø Piping mtr 500
c 250 mm Ø Piping mtr 200
d 200 mm Ø Piping mtr 310
e 150 mm Ø Piping mtr 100
f 125 mm Ø Piping mtr 50
g 100 mm Ø Piping mtr 500
h 80 mm Ø Pining mtr 400
i 65 mm Ø Pining mtr 450
j 50 mm Ø Piping mtr 100
k 40 mm Ø Piping mtr 20
l 25 mm Ø Piping mtr 10

2 SITC of CI Butterfly valve (PN-16) (16KLg/cm2 rating) as per Specifications with insulaction
519 as required.

Page-125 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

a 250 mm Ø Butterfly Valve each 26


b 200 mm Ø Butterfly Valve each 4
c 150 mm Ø Butterfly Valve each 4
d 125 mm Ø Butterfly Valve each 8
e 100 mm Ø Butterfly Valve each 20
f 80 mm Ø Butterfly Valve each 10
g 65 mm Ø Butterfly Valve each 80
h 50 mm Ø Butterfly Valve each 20

3 SITC of Swing check valve,C.I double flap , as per specification, (PN-16 Rating) with
520 insulaction as required.
a 250 mm Ø each 8

4 SITC of CI Balancing valve as per specifications, Rating No.PN-16.and insultion as requred


521
a 350 mm Ø each 4
c 250 mm Ø each 4
d 200 mm Ø each 2
e 150 mm Ø each 2
f 100 mm Ø each 2
g 80 mm Ø each 2
h 65 mm Ø each 2
i 50 mm Ø each 2

5 SITC of CI Y-type strainer, PN-16 rating, as per specifications and insultion as requred.
522
a 250 mm Ø each 8

6 SITC of water pressure guage (100 mm Ø) bourdon type with brass ball valve of 3/8" Ø and
SS tubing, socket.
523 Range (0-50) / (0-100) as required. each 100

7 SITC of Mercury in glass industrial thermometer in SS-304 casing with 0.5C least count,
range 0-50 C. Brass oil filled thermowell of 1/2" size.
524 each 80

8 SITC of Sintex Make HDPE bare expansion tank of 1000 litres capacity complete with bottom
support of red sand stone, inlet outlet nozzles, valves, float valves, level indicator.
Note : Tank is roof mounted.
525 each 2

(G) DRAIN PIPING

Page-126 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

1
SITC of GI - B class drain piping, as per specifications, complete with threaded fittings,
couplings, flanges, unions, u-traps, as required. Welding is not to be done on GI pipes. All
526 pipes to be leak tested, prior to insulation. Quote bare piping.
a 80 mm Ø mtr 200
b 65 mm Ø mtr 200
c 50 mm Ø mtr 100
d 40 mm Ø mtr 100
e 25 mm Ø mtr 200

(H) DUCTING & ANCILLARIES


1 SITC of Factory fabricated GI sheet duct work complete with all accessories, steel supports,
connection pieces of AHUs and specials shall be fabricated neatly, as per IS-655 and
attached specifications. Ducting as per specifications IS-655.
527
a 24 G (0.6 mm) (0-750mm) sqm 8000
b 22 G (0.8 mm) (751-1500mm) sqm 2000
c 20 G (1.0 mm) (1501-2250mm) sqm 3000

2 SITC of Volume control dampers, GI Black Painted dampers for control of air in branch ducts,
sqm
528 low leakage type as per specifications. 10

3 SITC of Fire and smoke dampers, as per specifications with U/L stamped fusible link, spring
loaded.
Supplying, fixing, testing and commissioning of fire dampers in supply air duct / main branch
and return air path as & where required of required sizes including control wiring. The
damper shall be motorized and spring return so as to close the damper in the event of power
failure automatically and open the same in case of power being restored. THe spring return
action shall be built mechanism and not extremally mounted. The damper shall also be
closed in the event of a fire signal which shall also be closed in the event of a fire signal
which shall be provided by the deparmtent in AHU room etc as per specifications as required.

529
a Fire Damper sqm 40
b Actuator each 35

4 SITC of Power coated, extruded aluminium SA diffusers with GI VCD (Black Painted).
530 sqm 20

5 SITC of Power coated, extruded aluminium RA diffusers without VCD.


531 sqm 20

Page-127 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

532 6 SITC of SA grills with VCD as per specifications (Aluminium). sqm 20

533 7 SITC of RA grills with VCD as per specifications (Aluminium). sqm 20

534 8 SITC of Powder coated, extruded aluminium continuous grills. sqm 20

9 SITC of Powder coated extruded aluminium fresh air intake louvers complete with washable
10µ filters, GI bird screen & aluminium VCD. Intake velocity 400 fpm.
535 sqm 10

(I) INSULATION
1 SITC of Insulation of expansion tank with nitrile foam 9mm thick with pidilite adhesive and
polythene sheet, there after. Finally 24 G aluminium cladding. (1000 litres capacity Sintex
536 Tank). job 2

2 SITC of chemically cross linked clsoed cell polythelene (XLPE) fire retardent grade insulation
of desrsity not less than 30kg per cum, 13 mm thick in a singler with factory lamination of 30
micron aluminium foil, as per specifications as enclosed
537
# SA Duct 13 mm thick sqm 10000

538 3 Duct Accoustic Lining


SITC of Duct accoustic lining with 30 kg per cum denesityglass wool, 10 mm thicknes,
covered with 26 gauge aluminum sheet with fixing arrangment / accessories as required
sqm 1100

(J) CONTROLS
1 Controls: 2 way Flow control valve
SITC of 2 Way flow control valve with temperature controller,actuator,Linkage for AHUs as
539 per Specifications.
b 65 mm Ø each 40
c 50 mm Ø each 12

(K) ELECTRICAL PANELS, WIRING & EARTHING

Page-128 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

1 Supply, installation, testing and commissioning of front operated, front / back access, cubicle
type, indoor duty, floor / wall / recess / surface mounted (as specified), totally enclosed dust
and vermin proof switchboards / panels with minimum Ingress protection classification of IP
54, fabricated from 2 mm thick CRCA sheets with dip coat priming and epoxy powder coated
finish. The panels must be suitable for 415 volts 3 phase, 4 wire, 50 Hz, system , must be
able to withstand symmetrical fault level of 65 KA (as specified for panels) for 1 sec at 415 V
and must include all interconnections, earthing and bonding requirements etc. The panels
must conform to drawings & standards specified in relevant specifications. The switch board
shall be as per CPWD specifications, SLD and as required.

540
a All Sub - main LV Switchboards must conform to the specifications.

b All the items mentioned in relevant clauses of the specifications and not specifically
mentioned in BOQ shall be deemed to be included in the quoted rates.

c In case of any contradiction between BOQ / specifications and drawings, the most stringest
conditions of the above will apply.

d The Switchboards shall be provided with detachable gland plates for entry of cables from the
top / bottom as required.
e All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The
busbars shall be insulated with heat shrinkable sleeves. SMC / DMC shrouds and busbar
supports suitably spaced shall be used. Hinged doors with padlocking facility shall be
provided on all outgoing feeders with switch handles lockable in OFF position.

f The panel shall have copper busbars as specified in the Specifications with bar type feeder
connections, spacers etc. with full sized neutral.

g Earthing all components, frame etc. to a common internal earth bar of size 50 x 6 mm Cu. or
higher, as required by the fault withstand level specified for the board.

Page-129 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

h All accessories & supporting structures such as channels, ISMC-75 base frame, mounting
brackets, lifting lugs, panel heaters, ventilation arrangement etc shall be provided as
required.

I Each incomer and outgoing feeder shall be provided with LED type status indication lamps
suitable for 240 V, AC, as approved.

j Space provision as specified in Specifications for future expansion.

k The make of all switchgear (ACB / MCCB / MCB) must be same to have total discrimination.

l Components and accessories shall be same for switchboards and panels for uniformity,
standardisation and replaceability and shall be applicable to all panels/ boards under the
scope of work.

m All interconnections, labeling, earthing, associated foundation / masonary work & erection
etc. complete shall be executed as required.

n MCCBs shall be as per the Specifications and shall be current limiting type with front
adjustable electronic releases for requred protections against fault, suitable for isolation as
per Annexure 7.1.2 of IEC 60947 – 2, with Ics and Icu values as specified in relevant clauses
of specifications and conforming to latest IEC60947. The operating voltage(Ue) shall be 415
V and insulation voltage (Ui) 690V with trip free mechanism, handle indicating ON / OFF /
tripped position. The breaking capacity as mentioned below shall be Ics values and shall not
be less then 50kA. Breakers must have Ics = 100% Icu. Electronic trip units shall comply with
the requirements as specified in Appendix F (EMC /EMI Compatibility) of IEC 60947-2 or EN
60947-2.

o ACBs/MCCBs shall be compact, suitably designed to provide protection of motors, cables,


busbars to suit rated current, unbalanced power distribution, as required.

Page-130 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

p Panel / Switchboard board design shall be compact and components / accessories of


compact sizes shall be used to economise the room space available. Employer reserve the
right to seek compact items inplace of larger ones.

q Incomer ACB'S / MCCBs / MCBs of switchboards / panels shall be provided with NO/NC
contacts as specified in specifications for interface with SCADA & for manual / auto operation
and local / remote operation.

r Voltage rating of shunt trip coil and closing shall be confirmed from BMS contractor during
Working Drawing preparation.

s ACB'a shall have Microprocessor based releases as specified in the Specifications.

t Over load releay for motor feeder shall finally be selected according to motor name plate full
load current by contactor.
u All motor feeder with thermal over load relay shall be provided with reset push button(to reset
in case of over load trip).
v Even though, ratings of MPCB / Contactors for Motor Feeders are mentioned in
BOQ/Drawings on the basis of a particular make of Switchgear, the contractor shall check the
rating with the driven equipment rating and select the the rating of these items accordingly
without any cost implications to the department.

Central Plant Panel as per Specification & Drawing Complete & as per brief description
given below:
One no Incomer consisting of following-

Page-131 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

1 No. 2500 A, 415V, 50kA, 4 Pole, Electrically operated Draw Out type, ACB complete with
safety shutters, 240V AC shunt trip coil & closing coil and having microprocessor based
releases with (1) Communication capability (2) Provision for measurement of three phase
current (3) Protection against long time + short time + earth fault (all with adjustable time
delays) + instantaneous (4) Zone Selective Interlocking Unit for Total Discrimination (5)
Communication options to remotely read and set parameters for the protection functions,
transmission of ammeter measurements (6) Signailing of the cause of tripping and alarms,
maximeter reset etc (7) NO / NC contacts for interlocks and indications (8) 1 no CT in neutral
to connect with the trip unit.

TNC switch
Auto / Local / Remote Selector Switch key operated.
LED indication lamp for ON, OFF & TRIP & Phase indication R-Y-B.
Metering
1 No Digital Voltmeter with In built Selector Switch.
1 No Digital Ammeter with Inbuilt Selector Switch.
3 Nos. CTs 2500/5A, 15VA, CL-1 for metering.
1 Nos. CTs2500/5A, 15VA, CL-1 for APFCR relay.
BUS-BARS
Electrolytic high conductivity T P & N copper conductor bus-bars (as specified in the
Specifications) rated 2500 Amps, suitable to withstand symetrical fault level of 50 KA for 1
second at 415 volts.

OUT GOING FEEDERS


a 3 nos outgoing feeders for Chiller motors of each shall be equipped with the followings but
not limited to:
1 No. 1250 A, 415V, 50kA, 4 Pole, Electrically operated Draw Out type, ACB complete with
safety shutters, 240V AC shunt trip coil and having microprocessor based releases with (1)
Protection against long time + short time + earth fault (all with adjustable time delays) +
instantaneous (2) NO / NC contacts for interlocks and indications (3) 1 no CT in neutral to
connect with the trip unit.

Auto / Local / Remote Selector Switch key operated.


LED indication lamp for ON, OFF & TRIP.
1 No Digital Ammeter with Inbuilt Selector Switch.

Page-132 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

3 Nos. CTs 1250/5A, 15VA, CL-1 for metering.


Power and Control terminals for cable connection.
b 3 Sets of Star - Delta Stater feeders for Primary Chilled Water Pump Motors of and each
shall be equipped with the followings but not limited to:

1 No. 3 Pole 100 A, 50kA at 415V, 3P Motor Duty MCCB (with inbuilt over load and short
circuit protection and having add-on type earth leakage protection ) over load range 30-50 A,
and auxiliary Contacts.
1 No. Digital Ammeter, CT operated.
1 No. CT 100/5A, 10VA, class - I for metering.
3 Nos. Contactors
1 No. overload relay
1 Lot interconnections, lugs and cable glands as required.
c 3 Sets of Star - Delta Stater feeders for Secondary Chilled Water Pump Motors of and each
shall be equipped with the followings but not limited to:

1 No. 3 Pole 100 A, 50kA at 415V, 3P Motor Duty MCCB (with inbuilt over load and short
circuit protection and having add-on type earth leakage protection ) over load range 30-50 A,
and auxiliary Contacts.
1 No. Digital Ammeter, CT operated.
1 No. CT 100/5A, 10VA, class - I for metering.
3 Nos. Contactors
1 No. overload relay
1 Lot interconnections, lugs and cable glands as required.
d 3 Sets of Star - Delta Stater feeders for Condenser Water Pump Motors of and each shall
be equipped with the followings but not limited to:

1 No. 3 Pole 160 A, 50kA at 415V, 3P Motor Duty MCCB (with inbuilt over load and short
circuit protection and having add-on type earth leakage protection ) over load range 100-125
A, and auxiliary Contacts.

1 No. Digital Ammeter, CT operated.


1 No. CT 100/5A, 10VA, class - I for metering.
Auto / Local / Remote Selector Switch key operated.
Working / Standby Selector Switch key operated.
Door mounted push buttons for Start and Stop functions.
Emergency stop push button lockable type.
LED indication lamp for ON, OFF, Trip.
3 No. 80A, AC-3 Duty, 3 - pole Contactor with Auxiliary Contacts and Operating Coil of 230 V
AC.
One no star delta timer.
Auxiliary Contactors for Auto / Local / Remote Operation.

Page-133 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

Power & control terminals for cable connections.


e 3 Sets of Star - Delta Stater unit for Cooling Tower Fan Motors of and each shall be
equipped with the followings but not limited to following:

1 No. 3 Pole 100 A, 50kA at 415V, 3P Motor Duty MCCB (with inbuilt over load and short
circuit protection and having add-on type earth leakage protection ) over load range 25-30 A,
and auxiliary Contacts.
1 No. Digital Ammeter, CT operated.
1 No. CT 100/5A, 10VA, class - I for metering.
Auto / Local / Remote Selector Switch key operated.
Working / Standby Selector Switch key operated.
Door mounted push buttons for Start and Stop functions.
Emergency stop push button lockable type.
LED indication lamp for ON, OFF, Trip.
3 No. 80A, AC-3 Duty, 3 - pole Contactor with Auxiliary Contacts and Operating Coil of 230 V
AC.
One no star delta timer.
Auxiliary Contactors for Auto / Local / Remote Operation.
Power & control terminals for cable connections.
f 2 Nos. 100 A, MCCB 4P, 25 KA Thermal Magnetic Based O/C S/C Release, RHOM.
each 1

2 SITC & Handing over of Wall mounted FCU panel board of cubical type fabricated from 2.0
mm thick CRCA Sheet having necessary cable alleys, powder coated through seven tank
process facility for picking and degreasing, including connections and interconnections as per
specifications for AHU motors only, including starters, contactors as per drawing approved
by the department.and and controls where applicable). Bus-Bar shell of copper, and the
incoming will have face indication lamps, and volt meter / ammeter with selector switch.

541 each 62

3 SITC & Handing over of Wall mounted AHU panel board of cubical type fabricated from 2.0
mm thick CRCA Sheet having necessary cable alleys, powder coated through seven tank
process facility for picking and degreasing, including connections and interconnections as per
specifications for Strip Heaters only including contactors for strip heaters as per drawing
approved by the department.and and controls where applicable.

542 each 35

Page-134 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

3 Chiller -LT Panel inter conection 1000 A Bus Trunking (sand-wich tipe,
65 ka/second, IP-55, C&S, L&T & GE make) arrangement in convenient sections with
Aluminium Bus Bars designed for a current density of 130 Amps per mm2 for use on 3phase
4 wire,415 Volts,50 Hz., A.C.supply including joints of sections, flexible joints, expansion
joints, bends and earthing with 2 runs of G.I. strip etc as per CPWD specfications and as
required.

543 mtr 45

4 SITC of Copper Conductor cable of suitable size for inter conection of Electrical Panal with all
the motors including their termination in to required cable end boxes, laid in ground / in trench
/ cable tray, as requred. Cable sizes will be as per CPWD specification.
544 job 1

5 Copper Plate Earthing


SITC of earthing station with copper plate of size 600 mm X 600 mm X 3 mm including
accessories like 40 mm dia pipe,masnory enclosure with cover plate having locking
arrangement,watering pipe, charcoal and salt complete as per CPWD specification and as
required.

545 lot 1

6 Providing and fixing of 25 mm X 5mm copper strip in 40 mm dia G.I Pipe from earth electrode
546 as required. mtr 100

7 Providing and fixing of 25 mm X 5 mm copper strip on surface or in recess for earth


connections per CPWD specification etc complete as required.
547 mtr 10

8 Providing and fixing 6 SWG dia GI Wire on surface or in recessfor loop earthing complete as
548 required. mtr 1500

9 Electrical Control wiring(Excluding BMS wiring): Providing & Fixing of Multicore armored
control (1.5 mm² copper) cabling, as required, for control and inter locking between electrical
panels and all field mounted controls.
This shall include all necessary control wiring as Following:
# Chillers to main panel.
# AHU two way valve modulating motor Controls to Panels, control wiring for thermostats,
safety thermostat, for heaters arranged in banks of 9 K.W.

549 lot 1

550 10 Supply & laying of rubber mat of size 1000 mm & 12 mm thick. sqm 30

Page-135 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

11 Supply & installation of ladder type 2 mm thick MS 'U' shaped channel tray ( including
horizontal & Vertical bends, reducers tees,cross member & other accessories as required &
duly suspended from the celling with M.S. suspenders ) of following sizes:

551
a 40 x 150 x 2 mm wide mtr 500
b 50 x 300 x 2 mm wide mtr 200
c 50 x 600 x 2 mm wide mtr 50

12 Providing and laying of double wall corrugated HDPE pipes, Rex / Zenduct / Duraline make
and of following sizes in existing channel or trench / ground / on surface including providing
and fixing necessary sockets / couplers / bends etc. on the way complete as required.
552
a 175mm (OD) / 150mm (nominal) (ID) mtr 1500
b 120mm (OD) / 100mm (nominal) (ID) mtr 1000

13 SITC of 100 A FP MCCB in enclosure (in MS box) including connection / interconnection


etc. as required Conforming to Specification for cooling tower.
553 each 3

(L) OZONE GENERATOR AND INJECTION SYSTEM FOR COOLING TOWERS


1 Supply, installation, testing and commissioning of Ozone Generator and Injection System for
Cooling Towers Capable of delivering 300 gm / hr at 10% wt.wt comprising of the following
and complete as per specifications.
554
i) 1 no. PLC based control panel comprising of Programmable logic controller, power
supply unit, Switch mode power supply, relay board, HT Transformer & DOL controller along
with HMI for pumps along with necessary switchgars for smooth operationof plant.
ii) 1 no. Air compressor non lubricating, reciprocating type having capacity
80CFM,1440RPM 95% filtering efficiency along with anti vibration pad etc. iii)
1 no. Oxygen plant (PSA based) iv) 1 no. Ozone electrode, vertical,
tubular, dual pass, water cooled 800gm/hr capacity made of SS316 with individual fused HT
element v) 1 no. hermatic reciprocating, air cooled water chiller
for operation on 3 phase, 415V AC supply. vi) 1no. Chiller pump set for
electrode cooling complete with end sectio, horizontal split casing, centrifugal pump with
TEFC induction motor, class 'F' insulation operating on 415 + 10 % volts, 3 phase, 50 cycles
AC supply.

Page-136 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

vii) 1 no. Recirculation pump set for compressor cooling complete with 1 no. end section,
horizontal split casing, centrifugal pump.TEFC induction motor class 'F' insulation operating
on 415 + 10% volts, 3 phase, 50 cycles AC supply.
viii) 1 no. Booster pump set with end suction, horizontal split casing, centrifugal
pump. TEFC induction motor, class, 'F' insulation operating on 415+ 10% volts, 3 phase, 50
cycles AC supply.

ix) 1 no. Liquid jet compressor (venturi injector)


x) 1 set. Non return valve and ball valve.
xi) 1 set, needle valve
xii) 2 set, rotatype flowmeter
xiii) 1 set, pressure indicator
xiv) 1 set, Solenoid valve
xv) 1 set, Water pressure switch
xvi) 1 no., Oxygen pressure switch
xvii) 1 no., Air filter having 5 micrometer filteration degree
xviii) 1 no., Air filter (mist separator) having 0.3 micrometer filteration degree

xix) 1 no. Air filter (micro mist separator) having 0.01 micrometer filteration degree

xx) 1 no side stream filtration with sand filter, filter pump & corrosin coupon rack

xxi) 1 lot, concrete foundationas required for the equipment. job 1

(M) BUILDING MANAGEMENT SYSTEM


1 Supply, Installation, testing and commissioning of Central Work Station of BMS comprising of
555 following. job 1
a Intel Pentium ( Latest ) machine with 2. GHz speed, 2.0 GB RAM 120 GB HDD,
Multimedia extenal modem as per specifications.
b Colour Monitor LCD - 21 inch
c 132 column 240 CPS printer (Alarm and report)
d Mouse
e UPS with 30 minutes battery backup

2 Supply, Installation, testing and commissioning of Software and System Interface Units of
556 BMS comprising of following.
a Developing, testing and commissioning of the software for the building automation
system along with necessary license.The Software shall be Web Based with unlimited IO
Points and User licenses. The BMS Software shall have on board Energy Report module ,
SMS and email alerts .The system software shall be Natve BACnet compliant. All controllers
shall be BTL ceitified & UL listed
each 1

Page-137 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

b Providing all necessary software and hardware for the interface of the following
system/equipment including providing necessary integrators/modules.
Water Cooled Chiller, Fire Alarm System , Diesel Generators , Secondary Pump VFDs.

lot 1
c Providing necessary BMS Interface Gateways for the BMS DDCs for Block A 1, A3 , B, C, D.
lot 1

3 Supply, lnstal!ation,testing and commissioning of following controllers as per the


557 specifications:
a Standalone 16/ 32 Bit Microprocessor Based intelligent Controller with real Time Clock,
Peer To Peer Communication & EEPROM as per the specifications. The
Contractor shall Estimate the required quantities of controller to suit the complete
requirement / operation as per I/O summary. The Controller shall be housed in lockable and
secure MS cabinets to be supplied along with controllers . System architecture design should
be in such a manner that every individual DDC is having at least 10% space I/O Point.
Communication protocol shall be Native BACnet at DDC level.

lot 1
b LCD Hand Held Portable Operator Terminals. each 1

4 Sensors and Field Devices


Supply, Installation, testing and commissioning of the following sensors / transmitters /
transducers / field devices as per the specifications.
558
a Immersion type temperaure sensors for measuring chilled water & condenser water supply
and return temperature each 5
b Duct type temperauture sensor for measuring return air at the Air Handling units.
each 36
c Duct Type Return Air Humidity Sensers for Return Air. each 36
d Out side air temperature Sensor for measuring the outside air temperature.
each 1
e Outsdie air humidity sensor each 1
f Pressure transmitter for measuring pressure in water lines each 4
g Electromagnetic type flow meters for Chilled water header each 1
h Differential Pressure switch across the Air Handling Units filters for indicating the filter status
each 36
i Differential Pressure switch across the Fan sections for indicating the fan status
each 36
j Level switches for indicating water levels in cooling towers, Tanks each 21
k Differential Pressure switch for pumps status each 12
l Duct CO2 sensors each 28

Page-138 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

m CO2 sensor with Outdoor enclosure each 1


n Flameproof Level switch each 3
o Flameproof Level transmitter each 1
p Voltage Transducer each 4
q Ph Sensor each 1

5 Supply,Installation.testing and commissioning of the following cables & Conduit as per


559 specifications :
a Signal cable , 2 Cx 1.5 Sq. MM., stranded tinned Cu conductor, Standard flexible, PVC
sheathed type. mtr 9250
b Communication cable 2Cx 1.5 Sq. MM , stranded tinned Cu conductor, flexible, PVC
sheathed, Shielded type. mtr 1500
c MS Conduits 25 mm mtr 5550
d MS Conduit 20 mm mtr 1500
Total Price of Section G

SECTION-H - LANDSCAPING
1 GRADED STONE AGGREGATE
Supplying and stacking of graded stone aggregate at site of size range :
560
a) 45 to 63 mm CUM 386.00

BRICKWORK
2 Brickwork with machine moulded perforated bricks of class designation 75 confirming to IS :
2222 -1991 in superstructure above plinth level upto floor five level in cement mortar 1:6 ( 1
cement : 6 coarse sand )
561 CUM 535.00
With F.P.S. bricks

3 PAVING/FLOORING
40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1
cement :5 coarse sand) with joints 3mm thick, side buttered with cement mortar 1:2 (1
cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with
same mortar
562
White sand stone SQM 890.00

4 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey
cement slurry mixed with pigment to match the shade of the slab including rubbing and
polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
563

Page-139 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

25 mm thick. SQM 416.00

5 Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished)
machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations
of required size of approved shade, colour and texture laid over 20mm thick base cement
mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with
matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to
edge to give high gloss finish etc. complete at all levels.

564
Area of slab over 0.50 sqm. SQM 250.00

565 6 Fire Clay Brick -Planting bed edging


Machine Made wire cut Fire clay bricks for paving & flooring pattern as/dwg. of size
230x115x40mm in approved make in all colours & shades, of any size as approved by
Engineer-in-Charge, over 12 mm thick bed of Cement Mortar 1:3 (1 Cement:3 Coarse Sand)
including necessary cutting, mitring, grouting the joints with fine, water-resistant, polymer
modified cement based powder grout mixed with pigment to match the shade of brick
complete.
SQM 135.00

7 40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1
cement :5 coarse sand) with joints 3mm thick, side buttered with cement mortar 1:2 (1
cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with
same mortar
566
Red sand stone SQM 350.00

8 PRECAST CONCRETE GRASS GRID PAVERS for Greenbelt pathway


567
Providing and laying 80mm thick factory made precast concrete interlocking grass grid
paving block of approved shape and of approved make over 80mm thick sand bed laid to
required gradient and finishing & cleaning of surface etc. all complete.
SQM 823.00

568 9 PRECAST CONCRETE DRAIN COVER


Providing & fixing in position precast concrete drain cover & frame of required shape &
approved quality of size 400 x 550 x75 NOS 1110

569 10 CURB STONE

Page-140 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

Providing and laying at or near ground level factory made kerb stone of M-25 grade cement
in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement:
3 coarse sand) including making joints with or without grooves (thickness of joints except at
sharp curve shall not to more than 5mm) including making drainage opening wherever
required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging
shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-
charge).

CUM 851.00

STEEL: BENCHES, LITTER BINS AND SIGNAGES


11 BENCHES
i Providing and fixing wrought iron / stainless steel benches as per approved manufacturer
570 each 65.00

ii SIGNAGES
Providing and fixing custom fabricated signage towers as per drawing and specifications i/c
materials using MS framework, SS finish, polycarbonate, vinyl and translights with composite
aluminum and SS base.
571
S1 nos 6.00
S2 nos 23.00

iii LITTER BINS


Providing and fixing GRP Fibre Sheet litter bins of approved manufacturer as per
572 specification. each 30.00
12 HORTICULTURE
12.1 Planting of Trees including cost of plants and necessary excavation of pits for plants as
573 shown in drawing no. 08008 B S5 LMP 001
T1 Alstonia scholaris ( Chhalm / Devils tree ) no. 70
T2 Azadirachta indica ( Neem ) no. 110
T3 Butca Monosperma( Butca, Palas, Dhak ) no. 50
T4 Cassia Fistula ( Amaltas ) no. 150
T5 Dekmix regia ( Gulmohur ) no. 175
T6 Emblica officianalis ( Amla ) no. 80
T7 Madhuca indica ( Madhuca / Mabua ) no. 75
T8 Mangifera indica ( Mango ) no. 75
T9 Polyenthia longifolia ( Ashoka ) no. 100
T10 Syzgium Cumini ( Jamun ) no. 75
T11 Tamarindus indica ( Imli ) no. 85
T12 Terminalia Arjuna ( Arjun ) no. 25

Page-141 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

12.2 Planting of Shrubs including cost of shrubs and necessary excavation as directed by
574 Engineer-in-charge. no. 1200

12.3 Trenching in ordinary soil up to a depth of 60cm including removal and stacking of
serviceable materials and then disposing of by spreading and neatly levelling with in a lead of
50m and making up the trenched area to proper levels by filling with earth or earth mixed with
sludge or/and manure before and after flooding trench with water (excluding cost of imported
earth, sludge or manure).
575 Cum 6000
12.4 Supplying and stacking of good earth at site including royalty and carriage up to 1 km (earth
measured in stacks will be reduced by 20% for payment).
576 cum 4000
12.5 Supplying and stacking sludge at site including royalty and carriage up to 1 km (sludge
measured in stacks will be reduced by 8% for payment).
577 cum 1000
12.6 Supplying and stacking at site dump manure from approved source, including carriage up to
1 km (manure measured in stacks will be reduced by 8% for payment) :
578
Screened through sieve of I.S. designation 4.75mm cum 1000
579 12.7 Rough dressing the trenched ground including breaking clods. 100sqm 20000
12.8 Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water
580 including disposal of uprooted vegetation. 100sqm 20000
581 12.9 Fine dressing the ground 100sqm 20000
12.10 Spreading of sludge, dump manure or/and good earth in required thickness (Cost of sludge,
dump manure or/ and good earth to be paid separately).
582 cum 6000
12.11 Mixing earth and sludge or manure in proportion specified or directed.
583 cum 6000
12.12 Grassing with ‘Doob’ grass including watering and maintenance of the lawn for 30 days or
more till the grass forms a thick lawn free from weeds and fit for mowing including supplying
good earth if needed (the good earth shall be paid for separately).
584
In rows 7.5 cm apart in either direction. 100sqm 20000

12.13 Half brick circular tree guard in 50 class designation bricks, internal diameter 1.25 metre and
height 1.2 metre above ground and 0.20 m below ground bottom two courses laid dry and top
three courses in cement mortar 1:6 (1 cement : 6 fine sand) and the intermediate courses
being in dry honey comb masonry as per design complete:
585
With F.P.S bricks each 1070.00

D LIGHTING FIXTURES

Page-142 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY RATE
IN FIG (RS) IN WORDS (Rupees)

Providing as fixing with complete cabling and other provisions required to mount following
light fixtures as per design / manufacturer as per drawing
586
1 L1 4.5m High Pole Light nos 39

2 L2 Alura 3.0M high Conical Post nos 6

3 W1 Water light with 20W LED with IP 68 protection nos 9

4 W2 Down light in water body with 40W LED nos 9

5 L3 Mini Bollards nos 8

6 Solar Garden Light


SITC of Solar Bollard Garden Light Aluminium profile with Diecast base, painted with PU
with frosted diffuser, corrote with 3 watt LED luminaire and solar charged battery, 1m high
along with CC foundation as reqd. ( TDM / HILITE / Bajaj)
nos. 250

Total Price of Section H

Signature of Bidder with seal.

Page-143 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
NAME OF WORK: CIVIL, STRUCTURAL, ELECTRICAL AND OTHER DEVELOPMENTAL WORKS
NAME OF PROJECT: CONSTRUCTION OF CAMPUS OF THE BIO-TECH SCIENCE CLUSTER (PHASE-1), FARIDABAD,
Bidding Doc. No.: A091/T-36/10-11/BB/01

Name of Bidder:

SCHEDULE OF RATES
SECTION- A- CIVIL WORKS

SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

SUBHEAD I : EARTH WORK


1 1.1 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over
areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal
of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be leveled and neatly
dressed.

(a) All kinds of soil cum 1447

2 1.2 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over
areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal
of excavated earth, lead upto 50 m and lift upto 1.5 m, disposed earth to be levelled and
neatly dressed.

(a) Ordinary Rock cum 4076


(b) Hard Rock(Blasting prohibited) cum 10088

3 1.3 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in
foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including
dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated
soil and disposal of surplus excavated soil as directed, within a lead of 50 m.

(a) All kinds of soil. cum 732

Page-144 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

4 1.4 Excavation work in foundation trenches or drains not exceeding 1.5 m in width or 10 sqm on
plan including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out
the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m.

(a) Ordinary rock cum 1463


(b) Hard Rock (Blasting prohibited) cum 5115

5 1.5 Excavating trenches of required width for pipes, cables, etc including excavation for sockets,
and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the
excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth
including consolidating each deposited layer by ramming, watering, etc. and disposing of
surplus excavated soil as directed, within a lead of 50 m:

(a) Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia.
metre 100

6 1.6 Excavating trenches of required width for pipes, cables, etc, including excavation for sockets,
depth upto 1.5 m including getting out the excavated materials, returning the soil as required
in layers not exceeding 20 cm in depth including consolidating each deposited layers by
ramming, watering etc. stacking serviceable material for measurements and disposal of
unserviceable material as directed, within a lead of 50m :

a Ordinary rock
Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia.
metre 3775
b Hard Rock ( Blasting prohibited )
Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia.
metre 505

7 1.7 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc.
in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and
watering, lead up to 50 m and lift upto 1.5 m.
cum 6296

8 1.8 Extra for every additional lift of 1.5 m or part thereof in.
a All kinds of soil cum 593

b Ordinary or hard rock ( Blasting prohibited ). cum 9851

9 1.9 Supplying and filling in plinth with local sand under floors including, watering, ramming
consolidating and dressing complete. cum 1232

Page-145 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

1.10 Supplying chemical emulsion in sealed containers including delivery as specified.


10
a Chlorpyriphos/ Lindane emulsifiable concentrate of 20% litres 5066

1.11 Diluting and injecting chemical emulsion (to be supplied free of cost at site of work) for PRE-
CONSTRUCTIONAL ANTI-termite treatment and creating a continuous chemical barrier
under and all around the column pits, wall, trenches, basement excavation, top surface of
plinth filling, junction of wall and floor, along the external perimeter of building, expansion
joints, over the top surface of consolidated earth on which apron is to be laid, surroundings of
pipes and conduits etc complete as per specifications (Plinth area of the building at ground
floor only shall be measured for payment) - Chlorpyriphos emulsifiable concentrate 20% with
1% concentration.

11 sqm 10118

1.12 Supplying and filling of good earth(excluding rock) in trenches, plinth,sides of foundation etc.
in layers not exeeding 20 c.m. in depth, consolidating each deposited layed by ramming &
watering including royalty and carriage for all lead and lifts.
12 cum 6195

SUBHEAD II - CONCRETE WORK


2.1 Providing and laying in position, cement concrete of specified grade excluding the cost of
centering and shuttering - All work upto plinth level :
13
a) 1:2:4 (1Cement : 2Coarse sand : 4 graded stone aggregate 20 mm nominal size ).
cum 29
b) 1:3:6 (1Cement : 3 Coarse sand : 6 graded stone aggregate 20 mm nominal size ).
cum 37.25
c) 1:4:8 (1 Cement : 4 Coarse sand : 8 graded stone aggregate 40 mm nominal size).
cum 2008
d) 1:5:10 ( 1Cement : 5 Coarse sand : 10 graded stone aggregate 40 mm nominal size.
cum 1208

2.2 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness)
including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses,
string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets
etc. up to floor five level, excluding the cost of centering, shuttering and finishing :

14
1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
cum 60

Page-146 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

2.3 Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as
per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse
sand) including the cost of required centering, shuttering and finishing smooth with 6mm thick
cement plaster 1:3 (1 cement : 3 fine sand) on exposed surfaces complete.

15
a 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
cum 48

2.4 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement :
2 coarse sand : 4 graded stone aggregate 12.5mm nominal size).
16 sqm 655

2.5 Extra for providing and mixing water proofing material in cement concrete work @ 1 kg per
kg
17 50kg of cement. 172

2.6 Applying a coat of residual petroleum bitumen of penetration 80/100 of approved quality
using 1.7kg per square metre on damp proof course after cleaning the surface with brushes
and finally with a piece of cloth lightly soaked in kerosene oil.
18 sqm 655

2.7 Making plinth protection with 25mm thick Kota stone fixed with 12mm thick cement mortar 1:3
(1 cement : 3 coarse sand) over base concrete 75mm thick cement concrete 1:5:10 (1
cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) complete in all
respect.
19 sqm 1338

SUBHEAD III - RCC WORK


3.1 Centering and shuttering including strutting, propping etc. and removal of form for :
20
a) Foundations, footings, bases of columns, etc. for mass concrete. sqm 4092
b) Walls (any thickness) including attached pilasters, butteresses, plinth and string courses,
Suspended floors, roofs, landings, balconies and access platform.etc.
sqm 43272

c) Lintels, beams, plinth beams, girders, bressumers and cantilevers. sqm 28654
d) Columns, Pillars, Piers, Abutments, Posts and Struts. sqm 19665
e) Stairs, (excluding landings) except spiral-staircases. sqm 1275
f) Small lintels not exceeding 1.5m clear span, moulding as in cornices, window sills, string
courses, bands, copings, bed plates, anchor blocks and the like.
sqm 235

Page-147 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

3.2 Extra for additional height in centering, shuttering where ever required with adequate bracing,
propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5
m, for every additional height of 1 metre or part thereof (Plan area to be measured)

21
Suspended floors, roofs, landing, beams and balconies (Plan area to be measured).
sqm 757

3.3 Providing, hoisting and fixing up to floor five level precast reinforced cement concrete work in
string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like
including the cost of required centering, shuttering, finishing smooth with 6 mm thick cement
plaster 1:3 (1 cement : 3 fine sand) on exposed surfaces complete but excluding cost of
reinforcement with 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal
size).
22 cum 213

3.4 Providing perforated holes using 25mm dia. PVC pipes in Precast RCC drain covers of 75 to
100 mm length including cutting and fixing in position complete(depth of hole shall be
23 measured for pavement) metre 2005

3.5 Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position
24 and binding all complete.
Thermo-mechanically treated bars of Fe 500. kg 2673192

3.6 Providing and laying in position ready mixed concrete manufactured in fully automatic
batching plant and transported to site of work in transit mixer for all lead having continuous
agitated mixer, manufactured as per mix design of specified grade for reinforced cement
concrete work including pumping of R.M.C. from transit mixer to site of laying , excluding the
cost of centering, shuttering finishing and reinforcement including cost of admixtures in
recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve
workability without impairing strength and durability as per direction of the Engineer - in -
charge. M-25 grade Reinforced cement concrete by using min. 380kg of cement per cum of
concrete. All works up to floor V level.

25 cum 14764
26 3.7 Add for providing richer mixes at all floor levels.
Providing M-30 grade concrete by using 400kg of cement per cum of concrete instead of M-
25 grade R.M.C. cum 885

SUBHEAD IV - BRICK WORK

Page-148 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

4.1 Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in:
27
a) Cement mortar 1:4 (1 cement : 4 coarse sand) cum 1346
b) Cement mortar 1:6 (1 cement : 6 coarse sand) cum 824

4.2 Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level up to
floor V level in all shapes and sizes in :
28
a Cement mortar 1:4 (1 cement : 4 coarse sand) cum 415

4.3 Half Brick masonary with F.P.S. bricks of class designation 75 in superstructure above plinth
29 level to Floor V level.
a Cement mortar 1:4 (1 Cement : 4 Coarse sand) sqm 171

b Extra for providing and placing 2 Nos 6mm dia. M.S. bars at every third course of half brick
masonry. sqm 171

4.4 Brick work with clay flyash F.P.S. brick of class designation 75 in superstructure above plinth
30 level up to floor five level in :
a Cement mortar 1:6 ( 1 Cement : 6 Coarse sand ) cum 1407

4.5 Providing & fixing Autoclaved Aerated Cement blocks masonary with 200mm thick AAC
blocks in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand )
excluding M.S bars / anchors / ties / RCC band and PCC at all heights, lifts & leads,
scaffolding complete.
31 cum 7289

4.6 Providing & fixing Autoclaved Aerated Cement blocks masonary with 125mm thick AAC
blocks in superstructure above plinth level in cement mortar 1:4 (1 cement : 4 coarse sand )
including 2 no.6mm M.S bars at every third layer / anchors / ties / RCC band and PCC
including lifts & leads, scaffolding complete in all respect.
32 sqm 7984

SUBHEAD V - STONE WORK


5.1 Random rubble masonry with hard stone in foundation and plinth including levelling up with
cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20mm
nominal size) at plinth level with :
33
a Cement mortar 1:6 (1 cement : 6 coarse sand) cum 1066

Page-149 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

5.2 Random rubble masonry with hard stone in superstructure above plinth level and upto floor V
level including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12
graded stone aggregate 20mm nominal size) at window sills, celing level and the like with :

34
b Cement mortar 1:6 (1 cement : 6 coarse sand) cum 743

5.3 Stone work (machine cut edges) for wall lining etc. (veneer work) backing filled with a grout of
12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement
mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone
shade : (To be secured to the backing by means of cramps which shall be paid for
separately) :
35
White sand stone - Exposed face machine cut and table rubbed with rough backing.

a 30 mm thick sqm 5942

5.4 Providing and fixing stainless steel cramps of required size and shape for anchoring stone
wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2
(1 cement : 2 coarse sand) including making the necessary chases in stone and holes in
walls wherever required.
36 kgm 3169

SUBHEAD VI - MARBLE WORK


6.1 Marble work gang saw cut (polished and machine cut) of thickness 18mm for wall lining
(veneer work) in cement mortar 1:3 (1 cement : 3 coarse sand) including pointing with white
cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment to match
the marble shade: (To be secured to the backing by means of cramps, which shall be paid for
separately).
37
Area of slab upto 0.50 sqm sqm 2410

6.2 Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished)
machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations
of required size of approved shade, colour and texture laid over 20mm thick base cement
mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with
matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to
edge to give high gloss finish etc. complete at all levels.

38
a) Granite of any colour and shade
b) Area of slab over 0.50 sqm. sqm 1103

Page-150 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

6.3 Extra for providing edge moulding to 18mm thick marble stone counters, Vanities etc.
including machine polishing to edge to give high gloss finish etc. complete as per design
approved by Engineer-in-Charge.
39
a) Marble work metre 820
b) Granite work metre 11803

6.4 Extra for fixing marble /granite stone over and above corresponding basic item, in facia and
drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc.
40 complete. metre 159

6.5 Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen
platform, vanity counters and similar location in marble/Granite/stone work including
necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete.
41 each 185

6.6 Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50 cm
deep and 1.8 cm thick fixed in urinal partitions by cutting of chase of appropiate width with
chase cutter and embedding the stone in the chase with eppoxy grount or with cement
concrete 1:2:4 (1 cement:2 corse sand: 4 part graded stone aggregate 6 mm nominal size) as
per the direction of Engineer-in-charge and finished smooth.

42
a Granite stone of approved shade (both side polished) sqm 40

SUBHEAD VII - WOOD WORK


7.1 Providing wood work in frames of door, windows, clerestory windows and other frames,
43 wrought framed and fixed in position :
a second class teak wood cum 30

7.2 Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter
confirming to IS : 14616 and TADS 15:2001(Part B)including ISI mark black enameled MS
butt hinges with necessary screws as per direction of Engineer in charge and panneling with
panels of
44
(a) 12 mm thick prelaminated particle board (decorative lamination on both sides) grade 1,
medium density flat pressed, three layer particle board FPT 1 or graded wood particle board
FPT 1, conforming to IS :3087 with BWP type synthetic resin adhesive as per IS : 848 pre-
laminated conforming to IS :12823 Grade 1, Type II marked .

sqm 1483

Page-151 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

7.3 Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non
decorative type, core of block board construction with frame of 1st class hard wood and well
mached comercial 3 ply veneering with vertical grains or crossed bends and face veneers on
both faces of shutters.
45
a) 35 mm thick including ISI marked stainless steel butt hinges with necessary screws
sqm 406

7.4 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass
excluded) (overall area of door shutter to be measured) :
46
Rectangular or square sqm 8

7.5 Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).
47 sqm 1085

7.6 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats,
48 square or round bars etc. all complete.
Fixed to openings / wooden frames with rawl plugs screws etc. kgm 111306

7.7 Providing and fixing IS : 3564 marked aluminium extruded section body tubular type universal
hydraulic door closer with double speed adjustment with necessary accessories and screws
49 etc. complete. each 164

7.8 Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not
less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with
nuts and screws etc. complete :
50
a 300x16 mm each 33
b 250x16 mm each 762

7.9 Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than
grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with
necessary screws etc. complete :
51
a 250 x 10 mm each 1184
b 200 x 10 mm each 4403
c 150 x 10 mm each 3240
d 100 x 10 mm each 372

Page-152 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

7.10 Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and
a pair of lever handles with necessary screws etc. complete (best make of approved quality).
52 each 227

7.11 Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than
grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary
screws etc. complete :
53
a 125mm each 1482
b 100mm each 3236
c 75mm each 194

7.12 Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic
coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour
and shade with necessary screws etc. complete.
54
Double rubber stopper each 145

7.13 Providing and fixing decorative high pressure laminated sheet of plain/wood grain in
gloss/matt/suede finish with high density protective surface layer and reverse side of
adhesive bonding quality confirming to IS:2046 Type S including cost of adhesive of
approved quality.
55
1.00 mm thick sqm 1487

7.14 Providing and fixing stainless steel sheet of grade 308 machine cut 1.60mm thick of approved
quality on one face of 35mm thick flush doors shutters including cutting and stainless steel
screws etc complete.
56 sqm 357

7.15 Extra for providing ISI marked Stainless Steel butt Hinges instead of black enamelled M.S.
Butt hinges with necessary screws.(Shutter area to be measured)
57 sqm 1483

SUBHEAD VIII - STEEL WORK


8.1 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work,
including cutting, hoisting, fixing in position and applying a priming coat of approved steel
58 primer all complete: kg 101650

8.2 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and
3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete,
including applying a priming coat of approved steel primer.
59

Page-153 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

Using flats 30x6mm for diagonal braces and central cross piece. sqm 2

8.3 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths
interlocked together through their entire length and jointed together at the end by end locks
mounted on specially designed pipe shaft with brackets, side guides and arrangements for
inside and outside locking with push and pull operation complete including the cost of
providing and fixing necessary 27.5cm long wire springs grade No.2 and M.S. top cover of
required thickness for rolling shutters.

60
80x1.25mm M.S. laths with 1.25 mm thick top cover. sqm 75

61 8.4 Providing and fixing ball bearing for rolling shutters each 20

8.5 Extra for providing grilled rolling shutters manufactured out of 8 mm dia MS bar instead of
laths as per design approved by Engineer-in-charge. (Area of grill to be meaured)
62 sqm 15

8.6 Steel work in built up tubular trusses including cutting, hoisting fixing in position and applying
a priming coat of approved steel primer, welded and bolted including special shaped washers
63 etc. complete.
Hot finished welded type tubes. kg 13000

8.7 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp of
internal dia 140mm, 73mm height, top lid of 1.5mm thick M.S. sheet with its top surface
hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by
means of 3.3mm dia. round headed screws, one lock at the corners. Clamp shall be made of
12mm dia M.S. bar bent to shape as per standard drawing.

64 each 1244

8.8 Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in
position and applying a priming coat of approved steel primer using structural steel etc. as
65 required.
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
kgm 9204

Page-154 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

8.9 Providing and fixing stainless steel staircase railing, 915 mm ht from floor level with 38 mm
dia AISI 316 grade SS hand rail (Wall thickness 1.50mm),38mm dia. AISI 316 grade S.S top
mounted round Baluster with glass holding accessories (including top bracket to hold hand
railing), 10mm thick toughened frosted glass (600 mm height). Distance between two vertical
baluster approx 1200mm etc and including installation complete, as per drawing no 08008B-
S5-AD-801 and instruction of Engineer-in-charge

66 Metre 375

8.10 Providing and fixing steel cage made with welded-mesh 75x25 with mild steel wires of 4 mm
dia , welded over M.S iron frame 25x25x5 mm around and welding M.S flat iron 25x3 mm at
junction of mesh and angle iron frame,making small door opening and making locking
arrangement as per Arch. drawing and including priming coat of approved steel primer as per
instruction of Engineer incharge (mild steel section shall be separately paid under item no
8.1).
67 sqm 5450

8.11 Providing and fixing welded mesh 75x25 mm with mild steel wire 4mm dia.for steel doors
welded over M.S steel section, including providing and fixing necessary butt hinges, and
locking arrangement, complete and applying primer coat of approved steel primer as per
instruction of Engineer-in-charge. (Mild steel section shall be separately paid under item no.
8.1)
68 sqm 135

SUBHEAD IX - FLOORING WORK


9.1 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate)
finished with a floating coat of neat cement including cement slurry, but excluding the cost of
nosing of steps etc. complete.
69
40mm thick with 20mm nominal size stone aggregate. sqm 2824

9.2 52 mm thick cement concrete flooring with concrete hardener topping under layer 40 mm
thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement
hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume .hardening
compound is mixed @ 2 litre per 50kg of cement or as per manufacturers specifications. This
includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.

70 sqm 801

Page-155 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

9.3 Marble stone flooring with 18mm thick marble stone (sample of marble shall be approved by
Engineer-in-charge) over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4
coarse sand) laid and jointed with white cement slurry mixed with pigment including rubbing
and polishing complete with :
71
Udaipur green marble. sqm 1160

9.4 Cement plaster skirting (up to 30 cm height) with cement mortar 1:3 (1 cement : 3 coarse
sand) finished with a floating coat of neat cement :
72
18 mm thick sqm 55

9.5 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with white
cement slurry mixed with pigment to match the shade of the slab including rubbing and
polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
73
25 mm thick sqm 11481

9.6 Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm
(average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with white cement
slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing
complete.
74 sqm 1291

9.7 40 mm thick fine dressed stone flooring over 20 mm (average)thick base of cement mortar
1:5 (1 cement : 5 coarse sand) including pointing with cement mortar 1:2 (1 cement : 2 stone
dust) with an admixture of pigment to match the shade of stone(size of stone slab is to be
decided by the Engineer in charge)
75
White Sand Stone sqm 665

9.8 Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab.
76 metre 2072

9.90 Extra for Kota stone/ sand stone in treads of steps and risers using single length up to 1.05
77 metre . sqm 620

9.10 Providing and fixing Granite stone flooring with 18mm thick granite ( Sample of granite stone
shall be approved by the Engineer-in-Charge ) over 20 mm(average) thick base of cement
mortar 1:4 ( 1 Cement : 4 Coarse sand ) laid and grouted with white cement mixed with
pigment of approved colour, jointing with white cement slurry including rubbing and polishing
complete.
78 sqm 1576

Page-156 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

9.11 Providing and laying Granite stone slab 18 mm thick in risers of steps , skirting and pillars laid
on 12 mm ( average ) thick cement mortar 1:3 ( 1 cement : 3 coarse sand ) jointed with grey
cement slurry mixed with pigment to match the shade of the slab , including rubbing &
polishing complete.
79 sqm 2681

9.12 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to
be specified by the manufacture ) of approved make in all colours, shades except burgundy,
bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps
and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and
jointing with white cement slurry @ 3.3kg per sqm including pointing in white cement mixed
with pigment of matching shade complete.

80 sqm 2652

9.13 Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the
manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as
White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4
Coarse sand) including pointing the joints with white cement and matching pigment etc.,
complete.
81 sqm 9581

9.14 Providing and laying mirror polished granite stone flooring with 18mm thick granite stone
(shade and sample of granite stone shall be approved by the Architect / Engineer-in-charge)
over 20mm (average) thick base of cement mortar 1:4 (1 cement 4 coarse sand) laid and
grouted with white cement mixed with pigment of approved colour, jointing with grey cement
slurry including rubbing and polishing complete.

82 sqm 2975

9.15 Providing and laying mirror polished granite stone slab 18mm thick in risers of steps, skirting,
dado and pillars laid on 12mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand)
and jointed with white cement slurry including treating the joints with cement mixed with
pigment to match the shade of the slabs, including rubbing & polishing complete.

83 sqm 567

Page-157 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

9.16 Extra for providing pre-finished 18mm thick full round nosing in treads of steps made up by
pasting (with approved adhesive) additional length of 50mm wide and 18mm thick granite
stone strip to granite stone steps including machine polishing to nosing to give high gloss
finish complete as per design approved by the Architect / Engineer-in-charge.

84 mtrs 90

9.17 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the
manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of
approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :
4 coarse sand) including grouting the joints with white cement and matching pigments etc.,
complete.
85
Size of Tile 60 x 60 cm sqm 13189

9.18 Providing and laying vitrified tiles of size as approved in skirting / dado laid on 12mm thick
bed of cement mortar 1:3 (1 cement : 3 coarse sand) & jointed with white cement slurry @
3.3 kg/sqm including pointing with white cement mixed with pigment of matching shade
complete.
86 sqm 10125

SUBHEAD X - ROOFING
10.1 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1
cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C.
sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1 cement : 3 coarse sand)
and a coat of neat cement rounding the edge sand making and finishing the outlet complete.

87 each 176

10.2 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :
13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for
thermal expansion.(i) Single socketed pipes.
88
110 mm diameter metre 2886

10.3 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for
unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing
with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.
89
a Coupler
110 mm each 339
b Bend 87.5 degree
110 mm bend each 176

Page-158 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

c Shoe (plain)
110 mm each 176

10.4 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC
rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of
required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4
coarse sand) and making good the wall etc. complete.

90
110 mm each 2389

10.5 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and
91 weighing not less than 440 grams. each 176

10.6 Providing and fixing at all height false ceiling including providing and fixing of frame work
made of special sections power pressed from M.S. sheet and galvanised in accordance with
zinc coating of grade 350 as per IS : 277 and consisting of angle cleats of size 25mm wide x
1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to
the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle
hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with
nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre
to which the ceiling section 0.5mm thick button wedge of 80mm with tapered flanges of
26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction
perpendicular to

92 sqm 22953
G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every
junction including fixing the gypsum board with ceiling section and perimeter channels 0.5mm
thick 27mm high having flanges of 20mm and 30mm long, theperimeter of ceiling fixed to
wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all
screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square
edges of the board with recommended filler, jointing tapes, finisher and two coats of primer
suitable for board as per manufactures specification and also including the cost of making
openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels
suitably fixed all complete as per drawing and specification and direction of the Engineer in
Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum board
conforming to IS: 2095- Part I.

Page-159 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

10.7 Providing and fixing thermal insulation of ceiling ( under deck insulation ) / wall with 75 mm
thick Dupont subtex insulation of polyster wool with mass , 600 grams per square meter, and
thermal insulation ' R ' value 1.12 sqm W/K. Backed with 82 gm tyvek air and water barrier,
vapour breathable non woven substrate made of HDPE , fixed to ceiling with metallic
insulation fastening pins of 100 mm length, washers and secured with the help of wire mesh
of 22 x 18 mm for top most ceiling of the building.

93 sqm 7001

10.8 Providing, installing/fixing skylight consisting of 10 mm thick multiwall Polycarbonate sheet


( GE make ) of required shade fixed to aluminium profile frame work with stainless steel
screws and supported on M.S tube frame work including EPDM gasket, GE silicon sealent
cold forged fasteners etc complete as per drawing no 08008A2-S5-AP001 and direction of
Engineer-in-Charge. The rate includes the cost of all the operations, labour, materials and
tests ( as applicable ) for proper completion of the work except for the M.S tubular framework
which shall be measured and paid separately under item no. 8.6 . ( For payment purpose the
area of finished polycarbonate sheet fixed in position shall only be measured ).

94 sqm 520

SUBHEAD XI - FINISHING WORK


95 11.1 12 mm cement plaster of mix :
1:6 ( 1 Cement : 6 Fine sand ) sqm 48936

11.2 15 mm cement plaster on the rough side of single or half brick wall of mix :
96
1:6 ( 1 Cement : 6 Fine sand ) sqm 24647

11.3 12 mm cement plaster finished with a floating coat of neat cement of mix :
97
1:3 (1 cement: 3 fine sand) sqm 933

11.4 15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat
cement on the rough side of single or half brick wall.
98 sqm 6306

99 11.5 6 mm cement plaster of mix :


1:3 ( 1 Cement : 3 Fine sand ) sqm 66650

Page-160 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

11.6 Providing and applying plaster of paris putty of minimum 2 mm thickness over plastered
surface to prepare the surface even and smooth complete.
100 sqm 122685

11.7 Pointing on stone work with cement mortar 1:3 (1 cement: 3 fine sand) :
101
Flush / Ruled Pointing sqm 1142

11.8 Distempering with 1st quality acrylic washable distemper (ready mixed) of approved
manufacturer and of required shade and colour complete. as per manufacturer's
102 specification.
Two or more coats on new work. sqm 137158

103 11.9 Applying primary coat :


a With ready mixed pink or Grey primer of approved brand and manufacture on wood work
(hard and soft wood) sqm 2601
b With ready mixed red oxide zinc chromate primer of approved brand and manufacture on
steel galvanised iron/steel works sqm 2712

11.10 Painting (two or more coats) on rain water, soil, waste and vent pipes and fittings with
synthetic enamel paint of approved brand and manufacture and required colour over a
priming coat of approved steel primer on new work.
104
a 100 mm diameter pipes metre 205
b 150 mm diameter pipes metre 1530

11.11 Painting with synthetic enamel paint of approved brand and manufacture to give an even
105 shade
Two or more coats on new work sqm 11547

11.12 Washed stone grit plaster on exterior walls of height upto 10m above level in two layers,
under layer 12mm cement plaster 1:4 (1 cement : 4 coarse sand) furrowing the under layer
with scratching tool, applying cement slurry on the under layer @ 2 kg of cement per square
metre, top layer 15mm cement plaster 1:1/2:2 (1 cement : 1/2 coarse sand : 2 stone chipping
10mm nominal size) in panels with groove all around as per approved pattern including
scrubbing and washing, the top layer with brushes and water to expose the stone chippings,
complete as per specification and direction of Engineer-in-charge (payment for providing
grooves shall be made separately).

106 sqm 16041

Page-161 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

11.13 Forming groove of uniform size in the top layer of washed stone grit plaster as per approved
pattern using wooden battens, nailed to the under layer including removal of wooden battens,
repair to the edges of panels and finishing the groove complete as per specifications and
direction of the Engineer-in-charge including finishing the groove with silicon treatment of
approved make complete.
15mm wide and 15mm deep groove.
107 mtrs 16041

11.14 Providing and laying white sand stone (Dholpur) strips 50mm wide 20mm thick in fixed over a
bed of 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) over external surface of
wall, including joints filled with white cement slurry and pointing with matching shade
complete.
108 mtrs 16885

11.15 Providing & fixing tray type ALUMINIUM COMPOSITE SHEET CLADDING OVER STEEL
FRAME WORK using Aluminium mill finish rectangular verticle tube size -50x150x2mm
having wt. 2.13kg/m & horizontal square tube size 50x50x2mm having weight 1.043 kg/m
including 4mm thick aluminum composite panel sheet with 0.5mm aluminium foil thickness,
backer rod, & the periphey of cladding panel shall be sealed with weather Silicone of Dow
Corning/Walker make, necessary screws & hardware etc., complete in all respect.

109 sqm 2925

11.16 Providing and fixing toilet cubicles with intermediate panel, Pilaster & door. The intermediate
panel is one continued panel without any joints. All intermediate panels,pilasters and doors
shall be 12mm thick with edges chamfered. The solid compact laminate ( Phenolic Core
Board) is based on thermosetting resins, homogeneously reinforced with cellulose fibres. Top
surface on both sides is melamine coated which is scratch and impact resistant, including
cost of self closing S.S hinges, adjustable legs, lock with indicator & coat hanger of approved
make complete as per architectural drawing no.08008B-S5-AD-301 & direction of Engineer-
in-Charge.

110 sqm 730

Page-162 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

11.17 Providing & fixing canopy with 16 mm thick multi cell poly-carbonate sheet of approved make,
projecting out from terrace level of THSTI/RCB Block and coping the end edge of canopy with
Aluminium U-channel, as per section mentioned in the drawing with polycarbonate U-profile
holding arrangement with cap at the end over the M.S section frame duly fixed with RCC.
Column/Beam/M.S box section including priming coat of approved steel primer complete as
per drawing no.08008B-S5-AD 703. ( M.S. frame work shall be paid for separately ).

111 sqm 180

11.18 Providing and fixing 38 x 38 mm glazed ceramic tiles of versatile venetia band or equivalent
on exterior wall face with Laticrete 30% adhesive as per manufacturer specification and
grouting the joints with Latapoxy grouts of required shade complete as per the directions of
Engineer-in-Charge.
112 sqm 1755

11.19 Providing & fixing Microcell Danpalon Panel system 16mm thick (minimum) conforming to
following specifications.The polycarbonate system consist of : 1)Panel shall be 16mm thick
(min.)single panel.2)Panel width shall not be less than 1040 mm to ensure best performance
for wind uplift, vibration, oil canning & visual appearance.3) The panels shall be uniform in
colour with an integral Microcell core. In a cross section, the core shall be constructed of tight
cells not to exceed 4mm x 4mm. Wide cell panel configurations greater than 4mm by 4mm
shall not be accepted. 4) The weight of the panel shall not be les than 3250gram per square
meter. 5)Panels shall be manufactured with Vertical Standing Seam at both sides of the
panel. Welding or gluing of upstands or standing seam is not acceptable. 6) Snap-on
connector to interlock the panels shall have a grip-lock double tooth locking mechanism to
ensure maximun uplift capability. 7) End-cap/Aluminium U-Profile (mill finish ) for ends. 8)
Panels shall be co-extruded UV protected and double tone with anti-glare

softlite colour on one side to prevent glare. 9) Panel manufacturer should have project
reference in India which is atleast 6 years old for a single project not less than 1,500sqm. UV
protected side shall always face the sun/top. The full system shall be fitted on MS purlins
perpendicular to direction of sheeting with purlin spacing as specified by the manufacturer.
Panels shall be secured with snap-on connectors. Panels shall be installed by a solution
provider and is including the cost of required M.S. purlins and is as per architectural drawing
no. 08008D-S5-AD 801. .

113 sqm 226

SUBHEAD XII - SANITARY INSTALLATIONS

Page-163 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

12.1 Providing and fixing water closet squatting pan low floor (Indian type W.C. pan) with 100mm
sand cast Iron P or S trap, 6 litre low level white P.V.C. 2/4 ltrs dual flushing cistern with
manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures
complete including cutting and making good the walls and floors wherever required :

114
White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot
rests. each 2

12.2 Providing and fixing white vitreous china wall mounted European type water closet (of
approved make) with CP bolts, nuts, CI chair or other hanging arrangement, with vitreous
china watersaver dual flush 6 ltrs flushing cistern and internal fittings, white solid
plastic/wooden/bakelite seat and cover with lid, CP brass hinge rubber buffers, with
accessories, CI/MS brackets painted with two or more coats of enamel paint of approved
shade over a coat of primer. C.P. brass screws and wooden cleats, including cutting and
making good the wall and floors wherever required.

115 each 164

12.3 Providing and fixing white vitreous china flat back or wall corner type lipped front low floor
urinal basin of 430x260x350mm and 340x410x265mm sizes respectively with automatic
electronic flushing cistern with standard flush pipe and C.P. brass spreaders with brass
unions and G.I clamps complete, including painting of fittings and brackets, cutting and
making good the walls and floors wherever required :

116
One urinal basin with 5 litre white P.V.C. automatic flushing cistern. each 48

12.4 Providing and fixing white viterous china Oval shaped wash basin of approved make of size
560 x 410 mm counter sunk with 32 mm dia. C.P.brass wastepipe, 15 mm C.P brass pillar
tap Gem/ Parko or equivalent make including cutting and making good the wall etc. wherever
required as per direction of the Engineer-in-Charge.
117 each 186

12.5 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I.
brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting
and making good the walls wherever required :
118
Kitchen sink with drain board
510x1040 mm bowl depth 250mm each 1

Page-164 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

12.6 Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain
with rubber plug 40mm C.P brass waste and 40mm C.P. brass trap with necessary C.P.
brass unions complete including painting of fittings and brackets, cutting and making good
the wall wherever required :
119
Size 600x450x200 mm each 88

12.7 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings
120 complete.
Flexible Pipe
32 mm dia each 175

12.8 Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality)
complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws
and washers complete.
121 each 186

122 12.9 Providing and fixing toilet paper holder :


C.P. brass each 164

123 12.10 Providing and fixing soil, waste and vent pipes :
a 100 mm dia.
Centrifugally cast (spun) iron socketed pipe as per IS: 3989 metres 1205
b 75 mm dia.
Centrifugally cast (spun) iron socketed pipe as per IS: 3989 metres 1205

12.11 Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron
(spun) pipe embedded in and including cement concrete blocks 10x10x10cm of 1:2:4 mix (1
cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of
cutting holes and making good the walls etc. :
124
a For 100 mm dia pipe each 375
b For 75 mm dia pipe each 491

12.12 Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm
125 thick, bolts and nuts complete
a 100 mm dia
Sand cast iron S&S as per IS - 3989 each 145
b 75 mm dia
Sand cast iron S&S as per IS- 3989 each 87

126 12.13 Providing and fixing plain bend of required degree.

Page-165 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

a 100 mm
Sand cast iron S&S as per IS - 3989 each 36
b 75 mm
Sand cast iron S&S as per IS - 3989 each 40

127 12.14 Providing and fixing heel rest sanitary bend.


a 100 mm dia.
Sand cast iron S&S as per IS - 3989 each 23
b 75 mm dia.
Sand cast iron S&S as per IS - 3989 each 24

12.15 Providing and fixing single equal plain junction of required degree with access door, insertion
rubber washer 3 mm thick, bolts and nuts complete.
128
a 100 x 100 x 100 mm
Sand cast iron S&S as per IS - 3989 each 55
b 75 x 75 x 75 mm
Sand cast iron S&S as per IS - 3989 each 74

129 12.16 Providing and fixing terminal guard:


a 100 mm
Sand cast iron S&S as per IS - 3989 each 32
b 75 mm
Sand cast iron S&S as per IS - 3989 each 41

130 12.17 Providing and fixing collar:


a 100 mm
Sand cast iron S&S as per IS - 3989 each 126
b 75 mm
Sand cast iron S&S as per IS - 3989 each 180

12.18 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings
131 of diameter:
a 100 mm each 950
b 75 mm each 775

12.19 Providing and fixing M.S. stays and clamps for sand cast iron/centrifugally cast (spun) iron
132 pipes of diameter
a 100 mm each 35
b 75 mm each 40

Page-166 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

12.20 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or
without vent arm complete, including cost of cutting and making good the walls and floors :
133
a 100 mm inlet and 100 mm outlet
Sand cast iron S&S as per IS - 3989 each 388
b 100 mm inlet and 75 mm outlet
Sand cast iron S&S as per IS - 3989 each 29

12.21 Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with
paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved
134 quality) for new work :
a 100 mm diameter pipe metre 668
b 75 mm diameter pipe. metre 613

12.22 Providing and fixing C.P.brass jali 100 mm dia of approved make floor type.
135 each 388

136 12.23 Providing and fixing C.P. brass Bottle Trap for Wash basin and sink.
Bottle trap 38mm single piece moulded with height of 270mm, effective length of tail pipe
260mm from the centre of the waste coupling 77mm breadth with 25mm minimum water seal,
weighing not less than 263gms.
each 25

12.24 Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm
distance from wall of standard shape with bracket of the same materials with snap fittings of
approved quality and colour. weighing not less than 105 gms.
137 each 92

12.25 Providing and fixing C.P.brass towel ring trapezoidal shape of approved make 215mm long,
200mm wide with a minimum distances of 37mm from wall face with concealed fittings
arrangement of approved quality
138 each 25

12.26 Providing and fixing C.P. towel rail complete with brackets fixed to wooden cleats with CP
brass screws with concealed fitting arrangement of approved quality .
139 each 10

12.27 Providing & fixing 125mm dia.3mm thick Stainless steel grating with frame for floor traps or
drains of required pattern including cutting & making good the floors complete.
140 each 29

Page-167 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

12.28 Providing & fixing C.P brass Health faucet with PVC Flexible Tube with wall hook of approved
141 make each 6

12.29 Extra for providing & fixing automatic flushing system to ensure flushing of urinal after being
used comprising of flush valve, all plumbing valves (solenoid valves etc.) automatic electronic
censors, PVC conduit, concealed copper wiring etc & any other items required to provide
satisfactorily functioning of system in place of PVC automatic flushing cistern of approved
make.
142 each 42

SUBHEAD XIII - WATER-SUPPLY

13.1 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for
hot & cold water supply including all CPVC plain & brass threaded fittings This includes
jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of
joints complete as per direction of Engineer in Charge.
143
62.50 mm nominal inner dia Pipes. metre 590

13.2 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and
144 making good the walls etc.
a 15 mm dia nominal bore metre 82
b 20 mm dia nominal bore metre 541
c 25 mm dia nominal bore metre 1753
d 32 mm dia nominal bore metre 50
e 40 mm dia nominal bore metre 50
f 50 mm dia nominal bore metre 50

13.3 Providing & fixing G.I pipes complete with G.I fittings & clamps including making good the
walls etc, Concealed pipe including painting with anti corrosive bitumastic paint, cutting
chases and making good the wall
145
a 15 mm dia nominal bore metre 1134
b 20 mm dia nominal bore metre 1635

13.4 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.
External Work.
146
a 65 mm dia. nominal bore metre 300
b 80 mm dia. nominal bore metre 1700
c 100 mm dia. nominal bore metre 4045

Page-168 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

13.5 Making connection of G.I. distribution branch with G.I. main of following sizes by providing
and fixing tee, including cutting and threading the pipe etc. complete :
147
a 25 to 40 mm nominal bore each 4
b 50 to 80 mm nominal bore each 5

13.6 Providing & fixing gun metal gate valve with C.I wheel of approved quality ( screwed end ) :
148
a 25mm nominal bore each 2
b 65 mm nominal bore each 12
c 80 mm nominal bore each 20
d 100 mm nominal bore each 10

13.7 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic
149 floats complete :
a 20 mm nominal bore each 20
b 25 mm nominal bore each 5

13.8 Providing and fixing uplasticised PVC connection pipe with brass unions
150
a 45 cm length
(i) 15 mm nominal bore each 540

151 13.9 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :
100 mm diameter each 2

13.10 Constructing masonry Chamber 30x30x50 cm, inside with 75 class designation brick work in
cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100
x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement :2
coarse sand : 4 graded stone aggregate 20 mm nominal size ) necessary excavation
foundation concrete 1:5:10 ( 1 cement :5 fine sand:10 graded stone aggregate 40mm
nominal size ) and inside plastering with cement mortar 1:3 (1 cement :3 coarse sand) 12mm
thick finished with a floating coat of neat cement complete as per standard design :

152
With F.P.S. bricks each 42

Page-169 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

13.11 Constructing masonry Chamber 90x90x100 cm, inside with 75 class designation brick work in
cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm.
top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC
top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size
) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand:10 graded stone
aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3
coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per
standard design :

153
With F.P.S. bricks each 2

13.12 Constructing masonry Chamber 60x60x75 cm, inside with 75 class designation brick work in
cement mortar 1:4 (1 cement : 4 coarse sand) for fire hydrants, with C.I. surface box 350x350
mm. top and 165 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement :
2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation
foundation concrete 1:5:10 (1 cement : 5 fine sand:10 graded stone aggregate 40 mm
nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm
thick finished with a floating coat of neat cement complete as per standard design :

154
With F.P.S bricks each 10

13.13 Painting G.I. pipes and fittings with synthetic enamel white paint over a ready mixed priming
155 coat, both of approved quality for new work :
a 15 mm diameter pipe metre 82
b 20 mm diameter pipe metre 541
c 25 mm diameter pipe metre 1753
d 32 mm diameter pipe metre 50
e 40 mm diameter pipe metre 50
f 50 mm diameter pipe metre 50

13.14 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved
156 quality :
a 15 mm diameter pipe metre 1134
b 20 mm diameter pipe metre 1615
c 65 mm diameter pipe metre 300
d 80 mm diameter pipe metre 1700
e 100 mm diameter pipe metre 4045

Page-170 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

13.15 Providing and filling sand of grading zone V or coarser grade all-round the G.I. pipes in
157 external work.
a 65 mm diameter pipe metre 300
b 80 mm diameter pipe metre 1700
c 100 mm diameter pipe metre 4045

13.16 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and
158 making long screws etc. complete (New work)
a 15 mm nominal bore each 65
b 20 mm nominal bore each 73
c 25 mm nominal bore each 65
d 32 mm nominal bore each 8
e 40 mm nominal bore each 8
f 50 mm nominal bore each 8
g 65mm nominal bore each 5
h 80 mm nominal bore each 10
i 100 mm nominal bore each 10

13.17 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI :
12701 marked with cover and suitable locking arrangement and making necessary holes for
inlet, outlet and overflow pipes but without fittings and the base support for tank.
159 litres 33000

13.18 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931
160
15 mm nominal bore each 180

13.19 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS
standards and weighing not less than 690 gms.
161
15 mm nominal bore each 89

13.20 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved
162 make conforming to IS:8931.
15 mm nominal bore each 572

13.21 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved
quality conforming to IS:8931 a) 15 mm nominal bore .
163
15 mm nominal bore each 202

Page-171 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

13.22 Providing and laying Double Flanged (screwed/ welded) Centrifugally (Spun) Cast Iron, Class
164 B (IS : 1536) :
100 mm dia C.I. Double Flanged Pipe metre 542

13.23 Providing and laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) Ductile Iron
Pipes of Class K - 9 conforming to IS : 8329 :
165
a 100 mm dia Ductile Iron Double Flanged metre 45
b 150 mm dia Ductile Iron Double Flanged metre 10
c 200 mm dia Ductile Iron Double Flanged metre 5

13.24 Cutting holes up to 15x15cm in R.C.C. floors and roofs for passing drain pipe etc. and
repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement :2
coarse sand : 4 graded stone aggregate 20 mm nominal size) mixed with water proofing
liquid compound including finishing complete so as to make it leak proof.(The job has to be
executed through a reputed agency dealing with water proofing work.)

166 each 45

13.25 Providing & fixing 15mm C.P brass two-way bib tap with C.P brass threaded flange complete,
including cutting and making good the walls wherever required, of approved brand &
167 manufacture. each 6

13.26 Providing & fixing 15 mm C.P. brass wall/counter mounting single hole mixture(of approved
make) fitting for kitchen sink/ wash-basin with swinging and Swivel spout complete including
cutting and making good the walls wherever required.
168 each 11

13.27 Providing & fixing 15mm C.P Laboratory Cock swan neck (of approved make ) in centre with
side nozel bib cocks three way complete including cutting and making good the walls where
required.
169 each 14

13.28 Providing & fixing 15mm C.P brass wall mounting auto self closing bib cock (of approved
make ) complete including cutting & making good the walls where required.
170 each 600

SUBHEAD XIV - DRAINAGE


14.1 Providing, laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement
mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete
171 :
a 100 mm diameter metre 20

Page-172 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

b 150 mm diameter metre 315


c 200 mm diameter metre 1020
d 300 mm diameter metre 114

14.2 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone
aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard
172 design:
a 100 mm diameter S.W. pipe metre 10
b 150 mm diameter S.W. pipe metre 250
c 200 mm diameter S.W. pipe metre 204

14.3 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone
aggregate 40 mm nominal size) upto Haunches of S.W. pipes including bed concrete as per
standard design:
173
a 100 mm diameter S.W. pipe metre 10
b 150 mm diameter S.W pipe metre 45
c 200 mm diameter S.W. pipe metre 816
d 300 mm diameter S.W. pipe metre 114

14.4 Providing and fixing square-mouth S.W. gully trap grade 'A'’ complete with C.I. grating brick
masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the
weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per
standard design :
174
100 x 100 mm size P type
a With FPS bricks class designation 75 each 46

14.5 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed
with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including
testing of joints etc. complete :
175
300 mm dia. R.C.C. pipe metre 500

Page-173 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

14.6 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand )
R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone
aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1
cement : 3 coarse sand) finished with floating coat of neat cement and making channels in
cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal
size) finished with a floating coat of neat cement complete as per standard design :

176
a Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610
mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of
cover 23 kg and weight of frame 15 kg) :

With FPS bricks class designation 75 each 43


b Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500
mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of
cover 58 kg and weight of frame 58 kg) :

With F.P.S. bricks class designation 75 each 5

177 14.7 Extra for depth for manholes.


a Size 90x80 cm
With F.P.S. bricks class designation 75 metre 1
b Size 120x90 cm
With F.P.S. bricks class designation 75 metre 1

14.8 Constructing brick masonry circular type manhole 0.91m internal dia at bottom and 0.56m dia
at top in cement mortar 1:4 (1 cement :4 coarse sand), in side cement plaster 12 mm thick
with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat
cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate
40mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2
coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of
neat cement all complete as per standard design :

178
0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560mm
internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than
182kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate
20 mm nominal size) including centering shuttering all complete. (Excavation, foot rests and
12mm thick cement plaster at the external surface shall be paid for separately) :

Page-174 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

With F.P.S. bricks class designation 75 each 22

14.9 Constructing brick masonry circular manhole 1.22m internal dia at bottom and 0.56m dia at
top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12mm thick with
cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement
foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm
nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse
sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat
cement all complete as per standard design :

179
1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560mm
internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than
182kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate
20mm nominal size) including centering shuttering all complete. (Excavation, foot rests and
12 mm thick cement plaster at the external surface shall be paid for separately) :

With F.P.S. bricks class designation 75 each 22

14.10 Extra depth for circular type manhole 0.91m internal dia (at bottom) with beyond 0.91m to
180 1.67m
With F.P.S. bricks class designation 75 metre 20

14.11 Extra depth for circular type manhole 1.22m internal dia (at bottom) beyond 1.68 m to 2.29
181 m:
With F.P.S. bricks class designation 75 metre 20

14.12 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete
blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as
per standard design :
182
With 20x20 mm square bar each 400

Page-175 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

14.13 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per
IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as
23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112
mm space between protruded legs having 2 mm tread on top surface by ribbing or
chequering besides necessary and adequate anchoring projections on tail length on 138 mm
as per standard drawing and suitable to with stand the bend test and chemical resistance test
as per specifications and having manufacture's permanent identification mark to be visible
even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6
(1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per
design.

183 each 716

14.14 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape
184 and approved quality :
a L D- 2.5
Rectangular shape 600x450mm internal dimensions each 40
b EHD - 35
Circular shape 560 mm internal dia. each 98

14.15 Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation
75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C.
horizontal grating with frame complete as per standard design :
185
With F.P.S bricks each 162

14.16 Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks of class
designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand ) with pre-cast R.C.C. vertical
grating complete as per standard design :
186
With F.P.S. Bricks each 20

SUBHEAD XV - ALUMINIUM WORK

Page-176 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

15.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with
extruded built up standard tubular sections/ appropriate Z sections and other sections of
approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with
fixing clips, or with expansion hold fasteners including necessary filling up of gaps at
junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections
shall be smooth, rust free, straight, mitred and jointed mechanically wherever required
including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless
steel screws, all complete as per architectural drawings and the directions of Engineer-in-
charge. (Glazing and paneling to be paid for separately) :

187
a For fixed portion
Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868,
Minimum anodic coating of grade AC 15)
kg 68419
b For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and
making provision for fixing of fittings wherever required including the cost of PVC / neoprene
gasket required (Fittings shall be paid for separately).

Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868,
Minimum anodic coating of grade AC 15)
kg 44575

15.2 Providing and fixing double glazed hermetically sealed glazing in aluminum window,
ventilator partition and structural glazing etc with 6 mm thick toughened glass of approved
make Nano series Tropicana green product code KT 455 or Asahi Classic Green
(Specifications : Light transmission 27% to 30% Reflection external 17% to 20%, Reflection
Internal 12% to 33%, solar factor 0.20 to 0.21, Shading coefficient 0.23 to 0.24 and U vlaue
1.6 to 1.8) or equivalent both side having 12 mm air gap including providing EPDM gasket,
perforated aluminum spacers, desiccants, sillicon sealant (Both primary and secondary
sealant) etc (framework to be paid separately under relevant item)

188 sqm 4693

15.3 Providing and fixing double action hydraulic floor spring of approved brand and manufacture
IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors
and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc.
complete as per the direction of Engineer-in-charge.
189
With stainless steel cover plate each 59

Page-177 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

15.4 Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing
weather silicon sealant over backer rod of approved quality as per architectural drawings and
direction of Engineer-in-charge complete.
190
Upto 5 mm depth and 5 mm width. metre 13709

15.5 Providing and fixing aluminium tubular handle bar 32mm outer dia, 3.0 mm thick & 2100 mm
long with SS screws etc. complete as per direction of Engineer-in-charge.
191
Anodized (AC 15) aluminium tubular handle bar. each 187

15.6 Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors
including necessary cutting and making good etc. complete.
192 each 8

15.7 Providing and fixing non-anodised aluminium (anodised transparent or dyed to required
shade according to IS: 1868. Minimum anodic coating of grade AC 15) sub frame work for
windows and ventilators a with extruded built up standard tubular sections of approved make
conforming to IS: 733 and IS : 1285 fixed with rawl plugs and stainless steel screws etc.

193 kgm 15223

15.8 Providing fixing aluminium casement windows fastener of required length for aluminium
194 windows with necessary screws etc. complete.
Anodised ( AC 15 ) aluminium each 3472

15.9 Providing and fixing 10mm thick toughened glass frameless door including providing all
hardware fittings comprising of two pivot hinges one each at top and bottom, one lock, two
handles 300 mm long and making necessary holes and fixing of door complete as per the
directions of Engineer-in-Charge (All hardware fittings of stainless steel ozone make or
equivalent and toughened glass of Saint Gobain, Modiguard or equivalent)

195 sqm 173

15.10 Providing and fixing wire gauge shutter with aluminium frame of anodic coating AC-15, using
galvanised steel wire gauge of average width of apature 1.4mm with wire of dia 0.63mm for
doors, windows & clerestory windows including ISI marked stainless steel butt hinges of
anodic coating grade AC-15 with necessary screws completeas per drawing no.-08008A1-
S5-AD906
196 sqm 232

SUBHEAD XVI - WATER PROOFING

Page-178 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

16.1 Providing and laying integral cement based treatment for water proofing on horizontal surface
at all depth below ground level for under ground structures as directed by Engineer-in-
Charge and consisting of : i) Ist layer of 22mm to 25mm thick approved and specified rough
stone slab over a 25mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed
with water proofing compound conforming to IS:2645 in the recommended proportion over
the leveling course (leveling course to be paid separately). Joints sealed and grouted with
cement slurry mixed with water proofing compound. ii) 2nd layer of 25mm thick cement
mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended
proportions. iii) Finishing top with stone aggregate of 10mm to 12mm nominal size spreading
@ 8 cudm/sqm thoroughly embedded in the 2nd layer.

197
Using rough kota stone. sqm 1105

16.2 Providing and laying integral cement based treatment for water proofing on the vertical
surface by fixing specified stone slab 22 mm to 25mm thick with cement slurry mixed with
water proofing compound conforming to IS:2645 in recommended proportions with a gap of
20mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with
neat cement slurry mixed with water proofing compound and finishing the exterior of stone
slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20mm thick with neat cement
punning mixed with water proofing compound in recommended proportion complete at all
levels and as directed by Engineer-in-charge :

198
Using rough Kota stone sqm 1386

16.3 Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed
portions of W.C., kitchen and the like consisting of :
199
i) Ist course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing
compound conforming to IS 2645 in recommended proportions including rounding off junction
of vertical and horizontal surface.

ii) IInd course of 20mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water
proofing compound in recommended proportion including rounding off junction of vertical and
horizontal surface.

iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 Kg. per sqm of
area.

Page-179 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be
100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm.)
sqm 2527

16.4 Providing and Placing in position suitable PVC water stops conforming to IS:12200 for
construction/ expansion joints between two RCC members and fixed to the reinforcement
with binding wire before pouring concrete etc. complete :
200
Serrated with central bulb (225mm wide, 8-11mm thick). metre 1025.00

16.5 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry
mixed with water proofing cement compound consisting of applying: a) after surface
preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement
compound @ 0.253 kg/sqm. b) laying second layer of Fibre glass cloth when the first layer is
still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5
mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing
cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to
air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken
upto 30cm on parapet wall and tucked into groove in parapet all around. d) fourth and final
layer of brick tiling with cement mortar (which will be paid for separately For the purpose of
measurement the entire treated surface will be measured.

201 sqm 971.00

16.6 Providing and laying integral cement based water proofing treatment including preparation of
surface as required for treatment of roofs, balconies, terraces etc consisting of following
operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed
with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge
over the RCC slab including adjoining walls upto 300mm height including cleaning the
surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25
mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with
water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over
20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water
proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required
slope

202

Page-180 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

and treating similarly the adjoining walls upto 300 mm height including rounding of junctions
of walls and slabs c) After two days of proper curing applying a second coat of cement slurry
using 2.75kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645
and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick jointless
cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound
conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth
of approved quality in top layer of plaster and finally finishing the surface with trowel with neat
cement slurry and making pattern of 300x300 mm square 3mm deep. e) The whole terrace
so finished shall be flooded with water for a minimum period of two weeks for curing and for
final test. All above operations to be done in order and as directed and specified by the
Engineer-in-Charge :

With average thickness of 120mm and minimum thickness at khurra as 65 mm.


sqm 10382

SUBHEAD XVII - MISCELLANEOUS

17.1 Providing and fixing chicken wire mesh of approved make fixed with nails etc. at junction of sqm 1033.0
RCC & brickwork complete, before cement plastering.
203

17.2 Making cable trench of size 600 x 600 mm inside, including necessary excavation, base metre 80.0
concrete with 1:4:8 ( 1 Cement : 4 Fine Sand : 8 graded stone aggregates 40 mm size ), brick
work for walls in 1:6 ( 1 Cement : 6 Coarse Sand ) , cement concrete flooring on base with
1:2:4 finished with neat cement inside plastering 12 mm thick in 1:3 ( 1 cement : 3 coarse
sand ) finished with a floating coat of neat cement, grating at top with angle iron frame and
M.S flat as per drawing and painting with enamel paint over steel grating complete.

204

17.3 Supply and filling of stone boulders size 50 to 200 mm in re-charge pit. cum 90.0
205

17.4 Supply and filling pea gravel 10 to 50 mm for rain water harvesting pit. cum 170.0
206

17.5 Supply and filling coarse sand 1.50 to 2.0 size in rain water harvesting pit well. cum 142.0
207

Page-181 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

17.6 Supply and filling pea gravel size 2 mm to 3 mm in around bore well pipe Rain water cum 495.0
208 Harvesting / pit well.

17.7 Providing and filing brick bats of 40 mm to 100 mm size for rain water harvesting pit. cum 24.0
209

17.8 Supplying and lowering 200 mm outer dia CPVC pipe confiriming to I.S :4985 working metre 2000.0
pressure 6 kgm/ sqm with necessary fithings to make required length complete in re-charge
210 pit.

17.9 Supplying and lowering 200 outer dia slotted (with slot size 3 mm) pipe confirming to I.S:4985 metre 280.0
(working pressure 6 kgm / sqm) with necessary fittings to make required length complete in
211 bore hole.

17.10 Praviding and fixing housing clamp, pipe cap and plug at the bottom of 200mm outer dia each 40.0
CPVC pipe complete with all fittings as per direction of Engineer-in-charge.
212

17.11 Providing & laying S&S centrifugally cast (spun) iron pipes ( Class A ) confirming to IS-1536 :
( For Fire-Fighting work ) in ground i/c excavation and reflling the trench etc as required.
213
a 150mm dia metre 1350.0
b 100mm dia metre 200.0

17.12 Providing, fixing, testing & commissioning of single headed gun metal, ISI marked oblique each 53.0
pattern hydrant landing valve Type 'A' with 80mm dia flanged inlet & 63mm dia instanteous
type female outlet complete with gun metal cap and chain, twist release type lug and all
accessories as per (IS:5290-1983).
214

17.13 Providing, fixing, testing & commissioning of First Aid-Fire Hose Reel wall mounting swinging each 53.0
type complete with drum, bracket, stop valve 20mm dia, 30m long high pressure dunlop hose
reel tubing with gun metal shutoff nozzle conforming to IS:8090-1976 with 5mm orifice plate.
The hose reel shall be as per IS:884-1985.
215

17.14 Providing, fixing, testing & commissioning of Non-percolating flexible hose (RRL type 'A') ISI each 142.0
marked (IS:636) 63mm dia x 15m long complete with instantaneous type gun metal 63mm
dia ISI marked male and female couplings (IS:903) bound and riveted to hose pipe with
copper rivets and 1.5mm copper wire.
216
17.15 Providing, fixing, testing & commissioning of gun metal 63mm dia short branch with 20mm each 71.0
217 dia nozzle ISI marked (IS:903).

Page-182 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

17.16 Providing and fixing weather proof hose cabinet fabricated from 1.6mm MS sheet with front each 18.0
glass door and locking arrangement, suitable to accommodate all the necessary pipes,
accessories, fittings etc. as per drawing. The cabinet shall be painted with one coat of primer
and 2 more coats of synthetic enamel paint of approved shade and shall be suitably mounted
on concrete bases. 2 WAY FIRE BRIGADE INLET" etc. shall be painted in approved colour
and shade.

218

17.17 Providing and fixing door with frame for all internal fire hydrants fabricated from 20x20x3 mm each 53.0
and 40x20x3 mm hollow box sections mounted with 8 nos. of 100mm MS anodised butt hinge
on MS angle frame of 45x45x5 mm size with hold fasts fixed to wall with PCC (1:2:4) blocks
100x100x100 mm including 2 nos. allen key lock for locking along with padlock arrangement
& fully glazed with 4 mm thick float glass approved by local Fire Authority, stove enameled
fire red finish with "fire hose" written on front & to accommodate following: -
Gunmetal single headed hydrant valve - 1 No.
Fire hoses 63mm, 15M long with accessories -2 Nos.
Short branch - 1 No.
First Aid Hose Reel - 1 No.
Fire Extinguisher - 3 Nos.
Fireman's Axe - 1 No.
Pressure Gauge - 1 No.

219

17.18 Providing and fixing 150mm dia two-way fire brigade inlet connection consisting of 63mm each 13.0
instaneously male coupling and a check valve protected by cap scored with a chain glass
bore etc. complete with one 150mm dia sluice valve and 150mm dia non-return valve (To be
connnected to riser).
220

17.19 Providing, laying, jointing & testing of Mild Steel black pipe (IS:1239 / IS:3895) heavy class
including cutting, screwing, welding etc. complete with fitting viz. tees, elbows, bends,
flanges, reducers etc. including providing anti-corrosive treatment (coating and wrapping)
with 4mm thick tape and holiday test check as per IS:10221 complete as required.
Note : Pipes upto and 50mm dia shall be threaded joints, above 50mm shall be welded.

221
150 mm diameter pipes metre 350.0

Page-183 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

17.20 Providing and fixing butterfly valves, wafer end type class PN 1.6 as per IS:13095 - 1991 or
BS:5155, including necessary nuts, bolts, gaskets etc. complete (without gear box).
222
150 mm dia each 40.0

17.21 Providing, fixing, testing & commissioning of gunmetal alloy Gate Valve ISI marked screwed
223 type (type-2) as per IS:778-1987.
25 mm dia each 53.0

224 17.22 Providing and fixing dial type pressure gauge at hydrant station.
Dial diameter 100mm, caliberation 0-15 kg/cm2 each 26.0

17.23 Air-Cushion-Tank (Air Vessel) 250mm dia x 1.0m high with dished top, made of minimum each 20.0
6mm thick MS sheet pipe / plate complete with 25mm dia brass Air Valve (ball type) 25mm
dia stop valve, pressure gauge with brass stop cock, nipple, tees, elbows, pipe and all
accessories as required including fixing brackets.
225

17.24 Providing and fixing standard Fire Man's Axe with heavy insulated rubber conforming to each 59.0
226 IS:926.

17.25 Providing and fixing with bracket / supports etc. wall mounted fire extinguishers as per detail
227 below:
a ISI marked (IS:2878) portable fire extinguisher of 4.5 kg capacity carbon-dioxide type flat each 53.0
base including valve, discharge hose of not less than 10mm dia, 1m long & complete in all
respects including initial fill with CO2 gas conforming to IS:307-1966 filled to a filling ratio of
not more than 0.667 of not more than 0.667 and wall suspension bracket.

b 5 Kg ABC' stored pressure type Dry Chemical Powder (Mono-Ammonium Phosphate) fire each 53.0
extinguisher with fixing hangers, hose, brackets, screws to required size etc. complete as per
IS:2171.

Page-184 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

17.26 Providing and laying design mix cement concrete in roads, taxi tracks and runways having a cum 496.0
minimum works test beam flexural strength of 30 kg. per cm2. at 28 days using not less than
340 Kg. of cement per cum of finished concrete, coarse sand and graded stone aggregate of
40mm nominal size in appropriate proportions as per specified design criteria approved by
Engineer-in-charge mechanically vibrated using needle and surface vibrators including steel
form work with sturdy M. S. channel sections including curing and providing and filling
construction joints and dummy joints with approved joint filler and primer including rounding
of the edges and filling the grooves 10x25mm deep at top for construction joints and
10mmx50mm deep at top for dummy joints with joint sealing compound (conforming to grade
B of IS : 1834) including making necessary arrangements for expansion joints etc. all
complete.

228

17.27 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement cum 62.0
in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement:
3 coarse sand) including making joints with or without grooves (thickness of joints except at
sharp curve shall not to more than 5mm) including making drainage opening wherever
required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging
shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-
charge).

229

17.28 Providing and fixing weather proof hose cabinet fabricated from 1.6mm M.S. sheet with front
glass door and locking arrangement, suitable to accommodate all the necessary pipes,
accessories, fittings etc. as per drawing. The cabinet shall be painted with one coat of
primer and 2 more coats of synthetic enamel paint of approved shade and shall be suitably
mounted on concrete bases. The sign, " YARD HYDRANT", shall be painted in "CAPITAL
LETTERS in white synthetic paint.

230
a Size - 900x600x1500 high (For Yard Hydrant & 2 way suction collecting head) Each 18.0

Page-185 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

17.29 Supply, Installation, Testing & Commissioning of Mild Steel pipe (IS:1239 Part-I) heavy class
including cutting, threading, welding etc. bends, elbows reducers, clamps, hangers, flanges
etc. including cutting holes in brick or RCC walls/slabs and making good the same complete
including the cost of structural work for supports fabricated from standard sections of required
sizes and thickness e.g. galvanised M.S. rods, angles channels, slotted angle, etc., cutting to
sizes, drilling welding fixing to insert plates, including painting with one coat of primer and two
or more coats of synthetic enamel paint of approved make and shade including all steel work.
Note : Pipes upto and 50 mm dia shall be threaded joints, above 50mm shall be
welded joints.

231
a) 150mm dia. Metre 220.0
b) 100mm dia. Metre 1240.0
c) 80mm dia. Metre 1300.0
d) 65mm dia. Metre 730.0
e) 50mm dia. Metre 610.0
f) 40mm dia. Metre 440.0
g) 32mm dia. Metre 4500.0
h) 25mm dia. Metre 5650.0

17.30 Constructing masonary chamber 90x90x100 cm, inside with 75 class designation brick work Each 2.0
in cement mortar 1:5 (1 cement: 5 fine sand) for sluice valve, with C.I. Surface box 100mm
top diameter, 160mm bottom diameter and 180mm deep (inside) with chained lid and RCC
top slab 1:2:4 mix. ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal
size) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded
stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement
: 3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per
standard design With F.P.S. bricks.

232

17.31 Providing, fixing, testing and commissioning pressure switches suitable for operating with Each 27.0
hydrant and sprinkler systems for working pressure of 7 Kg/cm² pressure including
electrical wiring complete as required. The electrical wiring will be paid under separate
233 item.

17.32 Providing, fixing, testing and commissioning of 15mm dia. Quartzoid bulb type sprinkler with
temperature rating at 68°/79°C made out of forged brass and in nikel chrome finish.
234

a) Pendent /upright /conventional type Each 2650.0

Page-186 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

b) Side wall type Each 25.0

17.33 Providing, fixing, testing & commissioning of annunciater Panel for flow control switches
comprise of 6 zones(4 working and 2 spare), providing Audio/Visual Indication of actuation
of Automatic Sprinkler system for each zone complete as per specifications. The panel
should have interface for connection to complete controlled building management system.
The panel should have :
235
a) Fault indication for each zone.
b) indication of zone fire
c) Fire/fault hooter.
d) Alarm Panel for fire/fault.
e) Battery for emergency.
f) Battery charger.
g) Mains supply. Each 5.0

17.34 Providing and fixing 25 mm dia inspecting & testing assembly with gunmetal isolation valve, Each 6.0
gunmetal sight glass, bypass valve & connected to drain line complete (excluding the cost of
236 drain pipe).

17.35 Providing and fixing electrically operated flow indicating switches with threaded connection
for a minimum flow of 90 lpm for indicating water flow in sprinkler branch line on each floor
with necessary junction box installed in accessible place.
237
a On 150/100mm dia Pipe Each 27.0
17.36 Providing and laying in MS conduit PVC insulated ISI marked copper control cable in existing
conduit (IS:694) from individual flow switches on each floor to annunciation panel installed in
fire control room including sleeves cable clips, supports for horizontal runs etc. complete of
size
238
a 2 X 1.5MM Sq Meter 500.0

17.37 Providing and fixing with bracket/supports etc. wall mounted fire extinguishers as per detail
239 below :
a) ISI marked water CO2 Expelled gas type extinguishers 9 litres capacity with discharge Each 5.0
tube, metal cap, 60 grams carbon dioxide cartridge complete in all respects.

a) ISI marked water CO2 Expelled gas type extinguishers 9 litres capacity with discharge Each 5.0
tube, metal cap, 60 grams carbon dioxide cartridge complete in all respects.

Page-187 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

b) ISI marked (IS:2878) Portable fire Extinguisher, of 4.5 kg capacity Carbon-dioxide type flat Each 53.0
base including valve, discharge hose of not less than 10 mm dia. 1m long & complete in all
respects including initial fill with CO2 gas confirming to IS:307-1966 filled to a filling ratio of
not more than 0.667of not more than 0.667and wall suspension bracket.

c) 5 Kg ABC' stored pressure type Dry Chemical Powder (Mono-Ammonium Phosphate ) fire Each 53.0
extinguisher with fixing hangers, hose, brackets, screws to required size etc., complete as per
IS:2171

d) ISI marked (IS:10204) Portable Fire Extinguisher, Mech. Foam type capacity 9 ltrs with gun- Each 5.0
metal cap and nozzle and complete respects in all respects including initial fill and wall
suspension.

SUBHEAD XVIII - ACOUSTIC TREATMENT


18.1 Providing and fixing 12mm thick marine ply with commercial facing on both sides in backing sqm 674.0
for wall paneling of different types as per detail given in Architectural drawing and fixed to
existing MS tubular framework fixed / projected from the wall with necessary steel screws and
a priming coat with approved wood primer on unexposed surface at all heights / levels and
position of wall paneling as given in drawing. The item shall include the cost of making
opening in plywood for services like AC, grills, light fitting fixture, fire smoke detectors and
also include the cost of all material, scaffolding and T&P required and labour involved in all
the operation to execute the job as per drawing and direction of Engineer-in-charge
complete. (The MS tubular framework shall be paid separately).

240

18.2 Providing and fixing 20mm thick wood wool Acoustic Board of 400 kg/cum conforming to IS : sqm 620.0
3308 panels of required size and pattern the wood wool board shall be fixed to the MS
tubular frame already fixed / projected from the walls with necessary steel screws etc. at all
heights / levels and position detail given in the drawing. The item shall include the cost of
making opening in wood wool board for services like AC, grills, light fitting fixture, fire smoke
detectors and also include the cost of all material, scaffolding and T&P required and labour
involved in all the operation to execute the job as per drawing and direction of Engineer-in-
charge complete. (The MS tubular framework shall be paid separately).

241

Page-188 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

18.3 Providing and fixing 25mm thick 2nd class teak wood skirting 100mm wide and of approved sqm 70.0
pattern fixed to wall paneling at required level on floor with necessary screws, nails and rawl
plugs etc. and with a priming coat of approved wood primer on unexposed surface as per
drawing and direction of Engineer-in-charge complete.
242

18.4 Providing and fixing MS tubular frame work for different type of wall paneling at all heights as sqm 674.0
per details of wall paneling given in Architect drawing. The tubular frame work shall be made
of MS tube 40x40mm x18guage framed with welded joints and fixed / projected from wall and
held up in position by 40x40x5mm MS angle iron holdfast of varying length as per
requirement of Architect drawing showing details of different type of wall paneling. The MS
angle iron holdfast shall be fixed/embedded in wall with cement concrete 1:2:4 (1cement :
2coarse sand : 4graded stone aggregate 20mm nominal size) blocks of size 10x10x10cm
including cutting the necessary holes in brick / RCC wall and making good the same. The
MS angle iron holdfast shall be provided at 600x1200mm center to center(i.e. in vertical
direction @ 1200mm and center to center and in horizontal direction 600mm center to center
The MS tubular framework shall be fabricated so as to make a grid size of 600x600mm. The
frame work shall be fixed to hold fast with help of 10mm dia. bolt of required length by making
necessary holes in the frame work and holdfast angle etc. The MS tubular frame and MS
angle iron holdfast shall be painted with two coats of synthetic enamel paint of approved
brand and manufaturer over a priming coat of zinc chromate red oxide approved steel primer.
The frame work shall also include the cost of making opening for services of AC, light fitting
fixture and smoke detectors etc. by providing extra MS tube member if required, as per
requirement of drawing, details given and direction of Engineer-in-charge complete.(For
payment purpose wall area of the portion of hall where wall paneling with above framework
provided shall be measured only. For projection from wall paneling the soffit area of that
finished wall panel shall also be measured.

243
The rate shall include the cost of all material, scaffolding, T&P required and labour involved in
all the operation like cutting, fabrication, welding, drilling of holes, hoisting, fixing in position,
painting of framework and scaffolding etc. to execute the item as per drawing and direction of
Engineer-in-charge complete).

Page-189 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

18.5 Providing and laying wooden flooring with 75x25mm steam beach wood planks fixed with sqm 208.0
tounge & groove joints complete over the teak wood framework as detailed in the Architect
drawing no. SGA-2006(IIID)-SH-S6-AC008. The wooden plank shall be of 1500mm length,
fixed in required pattern as given in drawing with necessary screws of required size and
length. The wooden planks shall be fixed over two layers of 12mm thick marine ply fixed in
staggered joint pattern to support teak wood framework. The first layer of 12mm thick marine
ply shall be fixed to wooden frame work with necessary nails & screws and then second layer
of 12mm thick marine ply shall be pasted with suitable adhesive to first layer, laid with
staggered joints and fixed to first layer and framework with necessary nails and screws as
required. The support framework shall be of second class teak wood battens of required
sizes treated with two coats of fire retarder primer FR 881 undiluted @ 3.5sqm/litre. The
frame work batten of size 75x50mm shall be placed at 900 c/c in length wise direction and
teak wood battens of size 50x50mm shall be placed at 400mm c/c in shorter direction fixed
over longer direction wooden member by cutting 25mm deep rebate in longer side member.
The longer direction wooden frame batten shall be supported on 200x200mm LVL grout of
maximum varition 1:500 over which a 150x150mmx8mm thick ribbed Resistoflex (neoprene
Pads) (50 PSI grade) placed at 900x900mm c/c. Over the neoprene pad the main member
shall be held in position with two numbers 150mm long 50x50x6mm MS angle cleats fixed to
floor with two number 12.5mm dia. dash fastener of required length each on both angle cleat,
and shall be fixed to wooden frame with 2 numbers 10mm dia. bolts of required length.

The angle cleat shall be painted with 1 coat of zinc chromate red oxide steel primer. The
empty space between the wooden frame work shall be provided with 50mm thick resin
bonded fibre glass wool pads of density 24kg/cum. The frame work near the front as of stage
shall be provided as per detail given in above drawing. The steam beach wood / teak wood
panel shall be polished with polyurethene matfinish polish after making the base smooth with
necessary filling after sanding the wooden surface with use of orbital mechanical sanders
complete as per drawing and direction of Engineer-in-charge.

244

Page-190 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

18.6 Providing and fixing 145x50mm steam beach wood moulding fixed on the edge of stage with sqm 71.0
shorter direction wooden frame member and marine ply leaving a 5mm air gap as per detail
shown in the architect drawing no.SGA-2006(IIID)-SH-S6-AC008 the steam beach wood /
teak wood moulding surface shall be made smooth by sand papering and wood fillers and
finally finished with wax polishing in natural colour complete as per drawing and direction of
Engineer-in-charge.

245
Total Price of Section A

SECTION- B- Internal Electrical Installation


SH-I - WIRING
1 Point wiring in steel conduit, with modular type switch
Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 Sq.mm FR PVC
insulsted copper conductor single core cable in surface / recessed steel conduit, with modular
switch, modular plate, suitable GI box and earthing the point with 1.5 Sq.mm FR PVC
insulated copper conductor single core cable etc as required.
246
a Group C point 4780
b Wiring for Twin control light point with 1.5 Sq.mm FR PVC insulsted copper conductor single
core cable in surface / recessed steel conduit, with two way modular switch, modular plate,
suitable GI box and earthing the point with 1.5 Sq.mm FR PVC insulated copper conductor
single core cable etc as required.
point 116
2 Wiring for power plug with 2x4 Sq.mm FR PVC insulated copper conductor single core cable
in surface / recessed steel conduit alongwith 1 No. 4 Sq.mm FR PVC insulated copper
conductor single core cable for loop earthing as required.
247 meter 10554
3 Wiring for power plug with 4x4 Sq.mm FR PVC insulated copper conductor single core cable
in surface / recessed steel conduit along with 2 Nos. 4 Sq.mm FR PVC insulated copper
conductor single core cable for loop earthing as required.
248 meter 3550
4 Wiring for 20A Industrial power plug point with 2x6 Sq.mm FR PVC insulated copper
conductor single core cable in surface / recessed steel conduit along with 1 Nos. 6 Sq.mm
FR PVC insulated copper conductor single core cable for loop earthing as required.
249 meter 2220
5 Supply and fixing 20A, 240V, SPN industriral type, socket outlet, with 2 pole and earth, metal
enclosed plug top along with 20 amps 'C'series, SP, MCB, in sheet steel enclosure, on
surface or inrecess, with chained metal cover for the socket out let and complete with
connections, testing and commissioning etc. as required.
250 each 131

Page-191 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

6 Supply and fixing 30A, 240V, TPN industriral type, socket outlet, with 4 pole and earth, metal
enclosed plug top along with 30 amps 'C'series, TPMCB, in sheet steel enclosure, on surface
or inrecess, with chained metal cover for the socket out let and complete with connections,
testing and commissioning etc. as required.
251 each 95
7 Supplying and fixing GI box along with modular base , cover plate ,1 no.6A modular switch &
2 nos. 6A sockets in recess etc as required.for computer terminal points.
252 each 512
8 Supplying and fixing following size/ modules, GI box along with modular base & cover plate
for modular switches in recess etc as required.
253
a 2 Module (75mm x 75mm) each 53
b 4 Module (125mm x 75mm) (Light Plug Point) each 1329
c 6 Module (200mm x 75mm) (Power Plug Point) each 1323
9 Supplying and fixing following modular switch/ socket on the existing modular plate & switch
box including conections but excluding modular plate etc. as required.
254
a 5/6 amps switch and 3 pin 5/6 amp socket outlet each 1329
b 15/16 amp switch and 6 pin 15/16 amp socket outlet each 1323
10 Circuit / submain /Light plug wiring in steel conduit:
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC
insulated copper conductor, single core cable in surface / recessed steel conduit as required.
255
a 2 x 1.5 Sq.mm + 1 x 1.5 Sq.mm earth wire for (Light plug) meter 12400
b 2 x 2.5 Sq.mm + 1 x 2.5 Sq.mm earth wire(Circuit wiring) meter 4280
c 4 x 2.5 Sq.mm + 2 x 2.5 Sq.mm earth wire(Circuit wiring) meter 1510
d 4 x 6 Sq.mm + 2 x 6 Sq.mm earth wire (Submain DB with timer /3 phase power point wiring)
meter 2700
e 4 x 16 Sq.mm + 2 x 16 Sq.mm earth wire (Submain wiring ) meter 2200
11 Supplying, installing, testing and commisioning of factory made ,painted powder coated paint
DLP Almunium trunking of Size 105x 50 mm on wall complete with fixing screws,
interconnections,joints, earthing etc. as required.
256 meter 850
12 Supplying, and fixing of factory made Almunium trunking cover of 85 mm width complete
257 with fixing screws etc. as required. meter 850

Sub-Head - II - Main Board, DB's & Cables

Page-192 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

1 S/F rising main :


Supplying ,installing on wall ,testing ,commissioning of following capacity rising main with
metal clad enclosure,wall straps , fully PVC insulated TPN aluminium busbars in convenient
sections and suitable for 400/650 volts,3phase,4 wire ,50 HZ,A.C.supply with extension
joints, fire proof barriers,expansions joints ,thrust pads including jointing ,and earthing with 2
runs of galvanised iron strips etc. as required .(Rising mains confirming to IS 8623,TEC 439 ).

258
a 400 amps (SC rating for 1 sec.-25 KA) metre 55
b 200 amps (SC rating for 1 sec.-20 KA) metre 55
2 S/F TPN tap-off box with TPN MCCB:

Supplying, installing, testing and commisioning of TPN tap off box of following capacity on
existing rising mains and complete with TPN MCCB of the following rating, interconnection,
earthing etc. as required.
259
a 100 amps TPN each 20
b 200 amps TPN each 20
3 S/F adopter box with cable end box gland:

Supplying, installing, testing and commisioning of adopter box of following capacity on


existing rising mains and complete with stand, cable end box, brass compression gland,
interconnection, earthing etc. as required.
260
a 400 amps TPN each 4
b 200 amps TPN each 4

261 4 S/F MCCB in cubicle panel board:/Rising Main


Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel
board including drilling holes in cubicle panel, making connection, etc. as required.

a 400 amps, 35 KA each 4


b 200 amps, 35 KA each 24
c 100 amps, 16 KA each 20
d 63/100 amps, 10 KA each 21

5 Providing and fixing on surface 63/100 amps rating and 16 KA breaking capacity MCCB in
MS sheet enclosure complete with supporting angle iron frame including drilling holes
,making connection, etc. as required.
262 each 19

Page-193 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

6 Fabrication, Supply, installation, testing and commissioning of wall/floor maounted cubicle


panels out of 1.6 mm thick CRCA MS sheet steel. All incomngs/ outgoings shall be arranged
in suitable size compartments with locking arrangement for each compartments, including
interconnection with 1100 V grade PVC insulated copper conductor, bus bar, labelling,
earthing, brass compression glands for incoming and outgoing cables, powder coted painting
etc. complete as required.

263
a MDB (Small Animal)
Incoming :
800A, 4P ACB (35 KA) - 1 No.
800 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
400 A TPN MCCB - 35 KA - 6 No.
Instruments
1 set of (0-500V) Digital Voltmete with protection fuses and selector switch.

1 set of (0-800A) Digital Ammeter with necessary CT's and selector switch.
1 set of R.Y.B indicating lamps.(LED type)
set 1
b MDB-P (THSTI)
Incoming :
800A, 4P ACB (35 KA) - 1 No.
800 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
400 A TPN MCCB - 35 KA - 3 No.
200 A TPN MCCB - 35 KA - 3 No.
100 A TPN MCCB - 25 KA - 1 No.
Instruments
1 set of (0-500V) Digital Voltmete with protection fuses and selector switch.

1 set of (0-800A) Digital Ammeter with necessary CT's and selector switch.
1 set of R.Y.B indicating lamps.(LED type)
set 1
c MDB-L (THSTI)
Incoming :
400A, TPN MCCB (35 KA) - 1 No.
400 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:

Page-194 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

200 A TPN MCCB - 35 KA - 3 No.


100 A TPN MCCB - 25 KA - 2 No.
Instruments
1 set of (0-500V) Digital Voltmete with protection fuses and selector switch.

1 set of (0-400A) Digital Ammeter with necessary CT's and selector switch.
1 set of R.Y.B indicating lamps.(LED type)
set 3
d (SDB -2) (Primate)
Incoming :
400A, TPN MCCB (35 KA) - 1 No.
400 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
125 A TPN MCCB - 25 KA - 3 No.
100 A TPN MCCB - 25 KA - 1 No.
63 A TPN MCCB - 16 KA - 5 No.
Instruments
1 set of (0-500V) Digital Voltmete with protection fuses and selector switch.

1 set of (0-400A) Digital Ammeter with necessary CT's and selector switch.
1 set of R.Y.B indicating lamps.(LED type)
set 2
e MDB P (Library)
Incoming :
630A, TPN MCCB (35 KA) - 1 No.
650 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
315 A TPN MCCB - 35 KA - 1 No.
125 A TPN MCCB - 35 KA - 4 No.
63 A TPN MCCB - 16 KA - 4 No.
Instruments
1 set of (0-500V) Digital Voltmete with protection fuses and selector switch.

1 set of (0-800A) Digital Ammeter with necessary CT's and selector switch.
1 set of R.Y.B indicating lamps.(LED type)
set 1
f MDB-P ( RCB)
Incoming :
800A, 4P ACB - 1 No.

Page-195 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

800 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
400 A TPN MCCB - 35 KA - 3 No.
200 A TPN MCCB - 35 KA - 3 No.
100 A TPN MCCB - 25 KA - 1 No.
Instruments
1 set of (0-500V) Digital Voltmete with protection fuses and selector switch.

1 set of (0-800A) Digital Ammeter with necessary CT's and selector switch.
1 set of R.Y.B indicating lamps.(LED type)
set 1
g MDB-L (Library)
Incoming :
400A 4P COS - 1 No.
315A, TPN MCCB (35 KA) - 1 No.
400 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
160 A TPN MCCB - 35 KA - 1 No.
63A TPN (16KA) MCCB.- 4 Nos.
Instruments
1 set of (0-500V) Digital Voltmete with protection fuses and selector switch.

1 set of (0-400A) Digital Ammeter with necessary CT's and selector switch.
1 set of R.Y.B indicating lamps.(LED type)
set 1
h MDB-L ( RCB)
Incoming :
400A, TPN MCCB (35 KA) - 1 No.
400 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
200 A TPN MCCB - 35 KA - 3 No.
100 A TPN MCCB - 25 KA - 2 No.
Instruments
1 set of (0-500V) Digital Voltmete with protection fuses and selector switch.

1 set of (0-400A) Digital Ammeter with necessary CT's and selector switch.
1 set of R.Y.B indicating lamps.(LED type)
set 1
i Autoclave Panel

Page-196 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

Incoming :
400A, TPN MCCB (35 KA) - 1 No.
450 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
100 A TPN MCCB - 25 KA - 6 No.
Instruments
1 set of (0-500V) Digital Voltmete with protection fuses and selector switch.

1 set of (0-400A) Digital Ammeter with necessary CT's and selector switch.
1 set of R.Y.B indicating lamps.(LED type)
set 1

7 Fabrication, installation, testing and commissioning of wall/floor maounted cubicle panels out
of 1.6 mm thick CRCA MS sheet steel, all incomngs/ outgoings shall be arranged in suitable
size compartments, locking arrangement for each compartments, including interconnection
with 1100 V grade PVC insulated copper conductor bus bar labelling, earthing, brass
compression glands for incoming and outgoing cables.

264
a (FDB-1 ) (Small Animal)
Incoming :
125 A TPN MCCB - 25 KA - 1Nos.
150 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
63A TPN (16KA) MCCB.- 4 Nos.
Indication
1 set of R.Y.B indicating lamps.(LED type) set 5
b (FDB-2 ) (SA, PR & ESS)
Incoming :
125 A TPN MCCB - 35 KA - 1Nos.
150 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
63A TPN (16KA) MCCB- 4 Nos.
100A TPN (25 KA) MCCB - 1 Nos.
Indication
1 set of R.Y.B indicating lamps.(LED type) set 6
c (FDB-L ) for THSTI
Incoming :

Page-197 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

100 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
40A TPN MCB- 4 Nos.
1 set of R.Y.B indicating lamps.(LED type) set 10
d (FDB-P1) for THSTI
Incoming :
200 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
63A TPN (16KA) MCCB- 3 Nos.
100A TPN (25 KA) MCCB - 1 Nos.
1 set of R.Y.B indicating lamps.(LED type) set 2
e (FDB-P2) for THSTI
Incoming :
200 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
63A TPN (16KA) MCCB- 4 Nos.
100A TPN (25 KA) MCCB - 1 Nos.
1 set of R.Y.B indicating lamps.(LED type) set 2
f (FDB-P3) for THSTI
Incoming :
200 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
63A TPN (16KA) MCCB- 6 Nos.
100A TPN (25 KA) MCCB - 1 Nos.
1 set of R.Y.B indicating lamps.(LED type) set 6
g (FDBP-1,2,3,4,7 ) of RCB
Incoming :
125 A TPN MCCB - 25 KA - 1Nos.
150 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
63A TPN (16KA) MCCB.- 6 Nos.
Indication
1 set of R.Y.B indicating lamps.(LED type) set 5
h (FDBP-8,9 ) of RCB
Incoming :
125 A TPN MCCB - 25 KA - 1Nos.

Page-198 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

150 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
63A TPN (16KA) MCCB.- 7 Nos.
Indication
1 set of R.Y.B indicating lamps.(LED type) set 2
i (FDBP-6 ) of RCB
Incoming :
125 A TPN MCCB - 25 KA - 1Nos.
150 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
63A TPN (16KA) MCCB.- 3 Nos.
Indication
1 set of R.Y.B indicating lamps.(LED type) set 1
j (FDBP-5,10 ) of RCB
Incoming :
125 A TPN MCCB - 35 KA - 1Nos.
150 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
63A TPN (16KA) MCCB- 4 Nos.
100A TPN (25 KA) MCCB - 1 Nos.
Indication
1 set of R.Y.B indicating lamps.(LED type) set 2
k (FDB-L ) for RCB
Incoming :
100 A TPN MCCB - 35 KA - 1Nos.
100 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
40A TPN MCB- 4 Nos.
1 set of R.Y.B indicating lamps.(LED type) set 10
l AHU Panel for RCB
Incoming :
200 A TPN MCCB - 35 KA - 1Nos.
200 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
63A TPN (16KA) MCCB- 7 Nos.
1 set of R.Y.B indicating lamps.(LED type) set 2
m AHU Panel for Library

Page-199 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

Incoming :
125 A TPN MCCB - 35 KA - 1Nos.
150 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
63A TPN (16KA) MCCB- 4 Nos.
1 set of R.Y.B indicating lamps.(LED type) set 2
n (FDB-P1) for library
Incoming :
125A TPN (25 KA) MCCB - 1 Nos.
150 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
63A TPN (16KA) MCCB- 3 Nos.
100A TPN (25 KA) MCCB - 1 Nos.
1 set of R.Y.B indicating lamps.(LED type) set 1
o (FDB-P2) for library
Incoming :
160A TPN (25 KA) MCCB - 1 Nos.
200 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
63A TPN (16KA) MCCB- 3 Nos.
100A TPN (25 KA) MCCB - 1 Nos.
1 set of R.Y.B indicating lamps.(LED type) set 1
p Lift Panel (SA, PR, THS & RCB)
Incoming :
100 A 4P Changeover Switch - 1Nos.
100 A TPN MCCB - 25 KA - 1Nos.
100 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
63A TPN MCCB - 2 Nos.
32/40A DP MCB - 2 Nos.
Indication
1 set of R.Y.B indicating lamps.(LED type) set 6
q AHU Panel (1&2) for SA
Incoming :
125 A TPN MCCB - 25 KA - 1Nos.
125 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:

Page-200 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

63A TPN MCB - 2 KA - 4 Nos.


Indication
1 set of R.Y.B indicating lamps.(LED type) set 2
r AHU Panel (1&2) for THSTI
Incoming :
200 A TPN MCCB - 35 KA - 1Nos.
200 A TPN AL. Bus Bars with coloured heat shrinkable PVC sleeve - 1Set

Outgoing:
100A TPN MCB - 25 KA - 1 No.
63A TPN MCB - 16 KA - 5 Nos.
Indication
1 set of R.Y.B indicating lamps.(LED type) set 2

8 SITC of Timer controlled prewired TP MCB DB:


Supply,Installation,Testing and comissioning of 4 way, three pole and neutral, prewired, sheet
steel, MCB distribution board, 415 volts, on surface / recess, complete with loose wire box,
terminal blocks, duly prewired with suitable size FR PVC insulated copper conductor up to
terminal blocks, tinned copper busbar, neutral link, earth bar, din bar, detachable gland plate,
interconnections, phosphatized and powder painted including earthing etc. as required ,
including contractor and timer switch on incoming MCB for automatic control (daily on/off ) of
lighting circuits.The DB with timer suitable to daily switch ON and switch OFF the ckts at a
predetermined times shall be with following accessories complete as required :

265
30 A TP Contractor of coil voltage 240 V
Time Switch
40 TPN MCB Isolator -1 No.
32 A DP RCCB - 3 No.
20 A SP MCB - 12 Nos. each 6

Page-201 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

9 S/F vertical type TP MCB DB:


Supplying,installation ,testing and comissioning of surface/ recess mounting,vertical type, 415
volts, prewired ,TPN MCB distribution board of sheet steel ,dust protected ,duly phosphatized
and powder painted ,inclusive of 200 amps tinned copper bus bar ,common neutral link,earth
bar, din bar for mounting MCB's,detachable gland /knock out plate and with built in loose wire
box and superior make terminal connector for all incoming and outgoiong circuits ,duly
prewired with adequate size of FR PVC insulated copper conductors upto the terminal
connector /neutral link and ready for installation of ways, and busbar of following ways (but
without MCB's and MCCB's) as required. (For Labs)

266
8 way each 32

10 S/F prewired TP MCB DB:


Supplying and fixing following way, three pole and neutral, prewired, sheet steel, MCB
distribution board, 415 volts, on surface / recess, complete with loose wire box, terminal
blocks, duly prewired with suitable size FR PVC insulated copper conductor up to terminal
blocks, tinned copper busbar, neutral link, earth bar, din bar, detachable gland plate,
interconnections, phosphatized and powder painted including earthing etc. as required. (But
without MCB / RCCB / Isolator).

267
a 4 way (4 + 12), Double door each 57
b 6 way (4 + 18), Double door each 51
c 8 way (4 + 24), Double door each 18
11 S/F TP MCB Isolator :
Supplying and fixing following rating, four pole, 415 volts, Isolator in the existing MCB DB
complete with connections, testing and commissioning etc. as required.
268
a 40 amps each 42
b 63 amps each 88
c 100 amps each 28

12 S/F DP RCCB :
Supplying and fixing following rating, Double pole, 415 volts,Residual curent circuit breaker
(RCCB) , having a sensitivity current upto 300 milliamperes in the existing MCB DB complete
with connection, testing and commissoning etc.as required.
269
a 40 amps each 157
b 63 amps each 239

Page-202 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

13 Supplying and fixing 5 amps to 32 amps rating, 240 volts, 'B' series, miniature circuit breaker
suitable for lighting and other loads of following poles in the existing MCB DB complete with
connections, testing and commissioning etc. as required.
270
Single pole each 2315

14 Supplying and fixing 20/32 amps rating, 415 volts, 'C' series, miniature circuit breaker suitable
for lighting and other loads of following poles in the existing MCB DB complete with
connections, testing and commissioning etc. as required.
271
20/32 A TP MCB each 93

15 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as
272 required. each 181

16 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at
least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in single
red colour on front side as required.
273 each 27

17 Supplying and laying of HD PVC pipe of following size for road/ floor crossing of cables at a
depth of 600mm below ground level including sealing of joints with solvent and sealing of
ends etc. complete as required.
274
100mm dia PVC pipe metre 190

18 Supply of following sizes of 1.1 KV grade single core/multicore aluminium conductor XLPE
insulated and PVC sheathed armoured cable conforming to IS 1554 (Part-I) 1988.
275
a 3.5 Core, 300 sq.mm. XLPE Aluminium Cable RM 200
b 3.5 Core, 185 sq.mm. XLPE Aluminium Cable RM 1120
c 3.5 Core, 120 sq.mm. XLPE Aluminium Cable RM 170
d 3.5 Core, 95 sq.mm. XLPE Aluminium Cable RM 260
e 3.5 Core, 50 sq.mm. XLPE Aluminium Cable RM 160
f 3.5 Core, 35 sq.mm. XLPE Aluminium Cable RM 250
g 4 Core, 25 sq.mm. XLPE Aluminium Cable RM 50
h 4 Core, 16 sq.mm. XLPE Aluminium Cable RM 550
Note: Actual length of cable should be verified at the site prior to the installation.
Incoming cables from ESS are not included in the scope of IEI.

Page-203 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

19 Laying and fixing of one number PVC/XLPE insulated and PVC sheathed Aluminium
conductor 3.5/4 core power cable of following sizes of 1.1 KV grade, direct in ground
including excavation, sand cushioning, protective brick covering etc. or fixing on wall/ ceiling
with MS clamps, nut bolts etc. as required.
276
a exceeding 25 sq.mm. But not exceeding 120 sq. mm. RM 1120
b exceeding 120 sq.mm. But not exceeding 400 sq. mm. RM 860
20 Supply and making cable end termination with brass compression glands and crimped
aluminium lugs following sizes of PVC sheathed / XLPE aluminium conductor cable of 1.1 KV
grade of the following sizes as required.
277
a 3.5 Core, 300 sq.mm. XLPE Aluminium Cable set 6
b 3.5 Core, 185 sq.mm. XLPE Aluminium Cable set 30
c 3.5 Core, 120 sq.mm. XLPE Aluminium Cable set 6
d 3.5 Core, 95 sq.mm. XLPE Aluminium Cable set 66
e 3.5 Core, 50 sq.mm. XLPE Aluminium Cable set 42
f 3.5 Core, 35 sq.mm. XLPE Aluminium Cable set 18
g 4 Core, 25 sq.mm. XLPE Aluminium Cable set 8
h 4 Core, 16 sq.mm. XLPE Aluminium Cable set 48

Sub Head - III Conduiting / Wiring for Telephone/LAN/TV


1 Supplying and fixing of following sizes of PVC conduit alongwith the accesories in
surface/recess including cutting the wall and making good the same in case of recessed
278 conduit as required.
a 20 mm metre 1800
b 25 mm metre 4200
c 32 mm metre 1200
2 Supply & Installation of 150x150x40 mm. deep 16 SWG factory fabricated MS junction box of
best quality complete with accessories, painting etc.,to be fixed in floor or on wall / ceiling
complete as required.
279 each 28
3 Supplying and fixing metal box of following sizes (nominal size) on surface or recess with
suitable size of phenolic laminated sheet cover in front including painting etc. required.
280
a 200x150x60 each 15
b 200x250x75 each 15
Telephone Wiring
4 Supplying and fixing of RJ-11 telephone socket outlet with GI sheet box and modular cover
281 plate complete as required:-
Single RJ-11 in One Plate. each 355

Page-204 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

5 Supplying & drawing following pair, 0.5 sq. mm. FR PVC insulated copper conductor,
unarmoured telephone cable in the existing surface/ recessed steel / PVC conduit as
282 required:-
2 Pair metre 9000
6 Supplying & laying/fixing of following pair, 0.5 sq. mm. FR PVC insulated copper conductor,
armoured telephone cable in the existing surface/ recessed steel / PVC conduit as required:-
283
a 10 Pair metre 250
b 20 Pair metre 200
c 50 Pair metre 100
7 Supply and installation of KRONE connector type main telephone tag block of following
sizes in sheet metal enclosure of suitable dimensions fabricated out of 16 SWG sheet steel
with castle key lock, hinged type cover including termination of telephone cables, making
connections, painting of box etc. complete as required:-
284
a 10 Pairs each 11
b 20 Pairs each 14
c 50 Pairs each 7
Computer System Wiring
8 Supply, drawing, testing & commissioning of 4 Pair CAT-6 Non-Plenum UTP cable of 24
AWG solid copper conductors complete as required.
285 metre 13410
9 Supplying, installation, testing & commissioning of RJ-45 Flush mounted information outlets
wired according to T 5688 standard with a surface mount box complete as required:-
286
Single Outlet in one Face plate each 533
Note: Computer system wiring shall include numbering and termination and testing of
cables at both the ends.( computer outlet points )

Sub-Head - IV - Installation of Light fittings, fans and fixtures


1 Installation, testing and commissioning of prewired, flourescent fittings / compact flourescent
fittings of all types, complete with all accessories and tube etc. directly on ceiling/wall/ False
ceiling, including connections with 1.5 sq.mm. PVC insulated, copper conductor, single core
cable etc. as required.
287 each 3664
2 Installation, testing and commissioning of prewired, fluorescent fittings of all types, complete
with all accessories and tubes etc., including supplying and fixing ball and socket 2 nos.
down rods of 20 mm. dia. x 1.6 mm. thick steel conduit upto 30 cm. length, painting and
wiring the down rods and connections with 1.5 sq.mm. PVC insulated, copper conductor,
single core cable as required.
288 each 543

Page-205 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

3 Installation of exhaust fan upto 450 mm sweep in the existing opening, including making the
hole to suit the size of the above fan, making good the damage, connections, testing,
commissioning etc. as required.
289 each 121
4 Installation, testing and commissioning of ceiling fan including wiring the down rods of
standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated, copper conductor, single
core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc.
as required.
290 each 563
5 Fixing louvers / shutters for exhaust fan:
Extra for fixing the louvers / shutters complete with frame for a exhaust fan of all sizes.
291 each 121

Sub Head - V - Supply of Light Fitting/Fans /Luminaries and Fixtures


1 Supplying of following lighting fixtures complete with special electronics low loss ballast/
lumilux tube/ lamp/ condenser/ starter /louvers/ reflector/cover etc. complete as required:-
292
a Surface Mounted Strip type flourscent fitting suitable for and with 1 no. 28 watt T5 lamps.
Philips / Instapower / Wipro / Osram as approved.
each 259
b Surface / recessed Mounted decorative flourscent fitting suitable for and with 2 nos 28 watt
T5 lamps.
Philips / Instapower / Wipro / Osram as approved. each 2170
c Mirror light fitting with 1 x 18 watt CFL lamp of Philips make Cat no. FMS 200/111 or
equivalent as approved. each 50
d Surface mounted 11 watt LED lamp Fitting.
Philips / Instapower / Wipro / Osram as approved. each 288
e Recessed mounted 9 watt Mirror Optic LED lamp fitting with lamp.
Philips / Instapower / Wipro / Osram as approved. each 741
f Surface / wall mounted Bulkhead luminarires 5 watt LED lamp. Philips / Instapower /
Wipro / Osram as approved. each 79
g Recessed mounted 25 watt Mirror Optic LED lamp fitting with lamp.
Philips / Instapower / Wipro / Osram as approved. each 225
h Surface mounted wall /ceiling light luminaire with 1x11 watt LED complete as required.
Philips / Instapower / Wipro / Osram as
approved. each 21
i Brick light luminaire 1X13 W PL lamp fitting suitable for 1 No. 13 W PL lamp with frosted
glass cover /acrylic diffuser of blue colour Cat .No. Decon 54SX02 or equivalent as
approved. each 35
j Indoor surface mounted down light 18 watt LED lamp fitting with cover.
Phillips / Instapower / Wipro / Osram as approved.
each 65

Page-206 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

k Surface Mounted Strip type flourscent fitting suitable for and with 1 no.28 watt TL5 lamps .
Philips TMS 122/128 EHF with 1x28 TL5 lamp / Instapone / Wipro / Osram as approved.

each 182
m 65W Decorative CFL open highbay fitting with 65 W PL Lamp
each 40
n Philips
RecessedHPK 205 1XPLEH
Mounted 65W
fitting 35 wattor equivalent
LED as approved.
downlighter.
Philips / Instapower / Wipro / Osram as approved. each 40
o Supply, installation, testing & commissioning of self contained 3 watt LED Sign Board
minimum five hour reserve) double sided emergency signalling unit for flag/suspension
mounting with suspension kit & having "EXIT" or "FIRE EXTINGUISHER" or "FIRE HOSE
REEL" as per actual mounting location complete with connections as required. Philips /
Instapone / Wipro / Osram as approved.

each 12
2 Supplying of Ceiling fans suitable for 230 Volt, 50 Hz, Single phase, A.C. supply and
complete without speed regulator all standard accessories such as blades & capacitor etc.
Makes CG/Usha/Havels
293
a 3 Blade-1200 mm Ceiling fan each 417
b 3 Blade-1400 mm Ceiling fan each 433
3 Supplying and fixing stepped type elctronic fan regulator on the existing modular plate switch
box excluding modular plate as required.
294 each 840
4 Supplying of following sizes of Exhaust Fans suitable for 230 Volt, 50 Hz, Single phase, A.C.
supply and complete with all standard accessories such as motors, blades & louvers, shutters
etc. in the existing opening i/c. making the hole to suit the sizes of the above fan & making
good the damages and connection with 1.5 Sq.mm PVC insulated FRLS copper conductor
wires from the point outlet to the fan as required. Makes GEC/Havels/Usha LX

295
a 300 mm dia. each 119
b 450 mm dia each 33
5 Supply, Installation,Testing and comissioning of 30 watt LED street lighting luminaries
complete as required.
296 Phillips / Instapone / Wipro / Osram as approved. each 35
6 supplying and fixing of 40 mm dia, 1 mtr. Long GI pipe Bracket , MS clamps ,nuts, bolts
,painting wiring etc. complete as required for installation of street light luminaire on the
297 building. each 20
7 Supply , Installation and commissioning of 3000VA Sine Wave Inverter complete with 80 AH
maintenance free inverter batteries including all accessories ,wiring, connections etc as
298 required. each 1

Page-207 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

8 Supply, Installation,Testing and comissioning of Blower type 2 KW Heat convector (room


heater) with two elements of 1 KW each, speed regulator and thermostat for temperature
control complete with all accessories as required. Make: Usha Lexus/Bajaj
299 each 27
9 Supply, Installation , testing and comissioning of Revoloving Type 600 mm air circulator fan
wall mounting with speed regulator.
300 Make : Almonard as approved. each 18
Sub-Head - VI - Earthing
1 Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm.thick including accessories, and
providing masonary enclosure with cover plate having locking arrangement and watering pipe
etc. (but without charcoal and salt) as required.
301 set 34
2 Extra for using salt & charcoal for G.I. plate earth electrode as required.
302 set 39
3 Providing and fixing 25mm x 5mm GI strip in 40 mm dia. G.I. Pipe from earth electrode as
303 required. metre 265
4 Providing and fixing 25 mm x 5mm GI strip on surface or in recess for connections etc. as
304 required. metre 340
5 Earthing with Copper earth plate 600 mm x 600 mm x 3 mm.thick including accessories,
and providing masonary enclosure with cover plate having locking arrangement and watering
pipe etc. (but without charcoal and salt) as required.
305 set 5
6 Providing and fixing 25mm x 5mm Copper strip in 40 mm dia. G.I. Pipe from earth electrode
306 as required. metre 55
7 Providing and fixing 25 mm x 5mm Copper strip on surface or in recess for connections etc.
307 as required. metre 85
8 Providing and fixing of lighting conductor finial, made of 25mm dia. 300mm long, G.I. tube,
haviing single prong at top, with 85mm dia. 6mm thick G.I. base plate including holes etc.
308 complete as required. mtr. 8
9 Providing and fixing G.I. tape 20mm x 3mm thick on parapet of surface of wall for lighting
conductor complete as required. (For Horizontal Run).
309 mtr. 1700
10 Providing and fixing G.I. tape 20mm x 3mm thick on parapet of surface of wall for lighting
conductor complete as required. (For Vertical Run).
310 each 430
11 Providing and fixing testing joint, made of 20mm x 3mm thick G.I. strip, 125mm long, with
4Nos. Of G.I. bolt, nuts, check nuts & spring washers etc. complete as required.
311 each 16

Sub-Head - VII - Fire Alarm System (Automatic Addressable)

Page-208 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

1 Supply fixing testing and commissioning of Analouge addressable photothermal type


photodetector type detector with mounting based LED with address switch to programmed
the detectors from 01-159 ,complete as required.The detector should be capable of
adjusting ,its sensitivity as per the change in the enviroment.(UL LISTED)

312
a) Ionisation type Smoke detector each 505
b) Ionisation type Heat detector each 215
2 Supplying fixing testing and commissioning of Addressable control modules for hooters,
AHU's , WFD Smoke detector, Leak detector, pressurising fans etc. .(UL LISTED)
313 each 115
3 Supplying fixing testing and commissioning of Addressable Manual call stations .(UL LISTED)
314 each 63
4 Supplying fixing testing and commissioning of Addressable sounders/electronics hooters
cum speakers as required for the fire detection and alarm system to be fixed at appropriate
height on wall on surface or in recess as required.
315 each 63
5 Supply,installation,testing aand commissioning of Microprocessor based 8 loop expandable
Analauge addressable type fire alarm control panel without any display.The panel should be
equipped of 4 loops with loop capacity to take 99 analauge addressable devices in one loop
and 198 total devices capacity,1000 event history, Four access levels,capable of taking
Flash scan devices flash EPROM sufficient numbers of programmable relay controls for
controlling AHU's ,pressurisation fans,ventlation fans at fire pump room,monitoring of fire
sprinkler and fire hydrant pump,240 V AC power supply ,automatic battery charger & inbuilt
24V sealed VRLA maintainance free batteries sufficient for 24 hours normal working and then
be capable of operating the system for 2 hours during an emergency conditions as required.

316 each 5
6 Supply Installation Testing & Commissioning of complete fire deduction and alarm system
complete as required including approval from local fire authorities.
317 Job 6
7 Supplying and laying/fixing of following sizes of 1.1 KV grade PVC insulated sheathed and
armoured Copper conductor control cable direct in ground including excavation, sand
cushing break covering and refilling the trench directly on wall/ceiling with MS clamps, nut
bolts etc. as required.
318
a) 2.5 sqmm / 4 core cable metre 610
b) 2.5 sqmm / 8 core cable metre 850
8 Supplying, drawing, connecting , testing of following single core PVC insulated FRLS copper
wires in existing conduit for Fire alarm System.
319

Page-209 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

a) 2x1.5 sqmm metre 2850


b) 3x1.5 sqmm metre 1600
c) 4x1.5 sqmm metre 900
9 Supplying and fixing of following sizes of steel conduit along with accessories in
surface/recess including painting in case of surface conduit, or cutting the wall and making
good the same in case of recessed conduit as required.
320
a) 20 mm dia metre 1450
b) 25 mm dia metre 2200
c) 32 mm dia metre 800
10 Supply, installation, testing & commissioning of self contained 2W LED (minimum one hour
reserve) double sided emergency signage unit for ceiling / wall mounting & having "EXIT" or
"FIRE EXTINGUISHER" or "FIRE HOSE REEL" as per actual mounting location complete
with connections as required
321 each 70
Total Price of Section B
SECTION- C- EXTERNAL ELECTRICAL INSTALLATION
SUB HEAD A: SUB STATION EQUIPMENT
H.T.PANEL
A-1 Supply, Installation, testing and Commissioning including design, manufacture and testing at
works of 11 KV HT VCB Panel board of 7 panels (2 no. incoming, 4 nos. outgoings & 1 no.
coupler) complete with all interconnections, labels, wiring etc. complete as detailed below
and as per specifications.
322
1 INCOMER - 2 NO.
630 A Vacuum circuit breaker of (350 MVA) 18.4 KA ruputuring capacity at 11 KV rated
totally enclosed, air insulated metal clad housing, floor mounting, vertical isolation, vermin
proof.fully interlocked horizontal drawout type having double isolation features and control
devices as per IS:13118, complete with the following.

.i Manually and motor operated, spring charged (release closing mechanism) trip free type,
pole truck mounted draw out Vacuum circuit breaker , incorporating mechanical as well as
electrical ON/OFF indication. Spring charge/discharge mechanical indication, OFF push
buttons for emergency trip (shrouded) test/ service position limit switches with 6 NO/6NC
breaker aux. contacts in service position.24 V DC shunt trip coil and 230V AC strip heater to
prevent moisture absorption. 630 amp air insulated but encapsulated, PVC insulated copper
bus bars etc as required.

ii CT chamber with double wound, dual ratio C.T's 200/100/5+5A separate core for metering
and separate core for protection.

Page-210 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

a 15 VA burden for protection (class 5P 10)


b 15 VA burden for instrumentation (accuracy class 1.0)
iii Voltage Transformer with 3 numbers 1 phase, 3 limbs connected in star dual class, 11KV/
3/110/ 3with drawable type with automtic shutters 100 VA burden on bus side with primary &
secondary fuses and isolating plugs, (Confirming to relevant IS specification).

iv Protection arrangement for the incoming breaker shall comprise of the following:

a. Numerical relay for over current & Eart fault protection - Areva P- III or equivalant of ABB /
Crompton make.
b. Anti pumping relay (94)
c. Master trip relay (86)
d. U/V relay.
v All wiring necessary for the above including interconnections. The size of the conductor
should not be less than 2.5 sq.mm. Copper wire where required.

vi Test terminal block fuses/2A SPMCB, circuit labels, set of phase, indication lamps etc. as per
standard practise as under :

a Red-Breaker close (ON)


b Green-Breaker open (OFF)
c Amber-auto trip
d Clear - trip circuit health
e White - 3 nos. one per phase
f Blue spring charged.
vii The following meters are to be provided.

a Digital multifuction meter for Montoring Voltage , Current , KWH & Frequency with shrouded
terminal & protection fuses.
b Ammeter range 0-100A-200A with necessary Ammeter selector switch dual graduated scale
shrouded termnal & 144 x 144 mmsq size.

viii 6-window annunciation panel with audio and visual indicator.

a Over current & earth fault 2 windows


b Spare 4 windows.
ix Necessary D.C supply healthy indication lamp and switch.
x control ;- T.N.C (Trip Neutral close) breaker control switch.
xi Cable end terminal boxes with single gland trifurcating cable box suitable for 11KV
aluminium XLPE (E) armoured cable of size 3x300Sq.mm for incoming breaker. Cable entry
shall be from bottom of the panel.

xii HT Danger Plate (as per IS specification)

Page-211 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

xiii 50x6 mm GI earth bus shall be provided for the full length of the panel.(2 Runs).

2 OUTGOING PANELS - 4 Nos.


Each outgoing 11 KV VCB panel for distribution transformer of 2000KVA shall be provided
with following :-
i Item no.I, .i, iv(b), iv(c), v, vi(a to f), ix, x, xii as detailed above for incoming panel shall be
provided for each of the outgoing panel and in addition following items shall be provided.

ii CT chamber with 1set of 2 core CTs with dual ratio 200/100/5+5amps.


15 VA burden for protection (accuracy class 5P10)
15VA burden for metering (accuracy Class 1.0)

iii Following protection shall be provided.


a) Numerical relay for over current & Eart fault protection - Areva P- III or equivalant of ABB /
Crompton make.
b) Auxalliry relay for T/F - for winding temp. , high alarm & tripping.
iv Following meters shall be provided.
a) Digital multifuction meter for Montoring Voltage , Current & Frequency with shrouded
terminal & protection fuses.
v 6-window annunciation panel with audio and visual indication.
a Over current & earth fault- 2 windows (CDG61).

b Oil temperature alarm & trip - 2 windows (OTI).


c Winding temperature alarm & trip - 2 windows (WTI).
vi Cable endTerminal boxes with single gland trifurcating cable box suitable for 11KV aluminium
XLPE (E) armoured cable of size 3x185Sq.mm for outgoing breakers.

3 COUPLER PANEL - 1 NO.


11 KV VCB coupler panel shall be provided with following :-
Item no.I, .i, iv(b), iv(c), v, vi(a to f), ix, x, xii as detailed above for incoming panel shall be
provided for each of the outgoing panel. board 1
323 A-2 2000 KVA TRANSFORMER (CAST RESIN DRY TYPE)

Page-212 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

Supply, installation, testing and commissioning of Cast Resin Dry Type 2000 KVA 11/0.433
KV,3 phase, 50 Hz, Dyn11 vector group, copper wound, class F insulation associated with
winding temperature indicator/controller actuated by means of resistance temperature
detector embedded in LV windings, indoor type Transformer with approximately 5%
impedence, tappings for OLTC, RTCC & AVR Operation on HV side in steps of +5% to
-15%, @ 1.25%, having cable end boxes on HV side suitable for 3x185 Sqmm XLPE cable
of 11KV grade and 2500 Amp. bus trunking arrangement on LV side with neutral brought out
separately including supplying and laying of copper conductor multicore control cable from
transformer to HT breaker for safety tripping, suitably mounted on M.S.channel i/c supplying
and grouting of suitable M.S. Channel with all accessories and confirming to IS 11171:1985 &
complete in all respects as required at site.

each 2
324 A-3 L.T.PANEL
Supply,Installation,Testing and Commissioning of L.T.Panel suitable for 415
Volt,3phase,4wire 50Hz AC supply system fabricated in compartmentlized from CRCA sheet
steel not less than 2mm thick duly treated with 7 tanks process, powder coated with approved
shade and oven dried . The complete panel will have a short circuit with stand capacity of 31
MVA for 1 Second, IP 42 rating. It will have a suitable MS base channel powder coated. The
panel will be fabricated in transportable sections. The panel shall have a common copper
earth bar of size 25mm x 5mm at the rear with 2 Nos. earth studs. The LT panel will have
suitable arrangement for bus-ducting/ cable termination into various incoming/outgoing
switchgear as required. Cable termination will be at suitable terminal block at top/bottom of
the panel and from the terminal block to switch, connection will be made with solid insulated
strip/PVC insulated copper conductor cable of required current rating as required. For other
construction details, refer to section IV of CPWD specifications, part IV- substations.

The panel shall be complete with following switchgear and accessories.

1 INCOMINGS FROM TRANSFORMER (2000KVA)

Page-213 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

2 nos. of 3200 amp rating motor operated spring charging four pole ACB (EDO) for 2000 KVA
transformer incomings , horizontal drawout type suitable for bus duct connection on incoming
side. The ACB shall be electrically interlocked covering 24V DC shunt trip circuit, under
voltage circuit & closing with bus couplers. and DG incomer .The panel shall be suitable for
operation on AMF. The breakers shall be provided with following:-

a Microprocessor release (SR-18G) having variable range of overcurrent, short circuit and
earth fault protection.
b U/V relay.
c TNC breaker control switch.
2 INCOMER FROM DG SET (1500KVA)
2 no. of 2500 amp rating motor operated spring charging TP ACB (EDO) for 1500KVA DG set
incoming , horizontal drawout type.The ACB shall be electrically interlocked covering 24V
DC shunt trip circuit, under voltage circuit & closing with bus couplers. and transformer
incomer. The panel shall be suitable for operation on AMF. The breakers shall be provided
with following:-

a Microprocessor release (SR-18G) having variable range of overcurrent, short circuit and
earth fault protection.
b 315 Amp. TP contactor for neutral.
c TNC breaker control switch.
d Reverse power relay with 5P 10 CT.
e U/V relay.
f Overvoltage relay.
3 Incomer panels from Transformer/ DG sets shall be provided with the following
indications/metering.
The indicating panel of the each Transformer incomer ACB shall be provided with the
following.
a MFM meter with CT`s. for Voltage , Current , KWH & P.F .
b 3 Nos. Phase indicating lamps backed upwith MCB.
c ON/OFF/ Trip indicating lamps
d Separate CT`s shall be provided for protection/metering / APFCR.
g CT for APFCR in T/R incomer panel (Ratio as per requirment of the capacitor panel)

4 Bus Bar
Set of 3600Amps rating TPN Almunium Bus Bars of suitable length shall be provided for
entire length of panel board.
5 Bus Coupler

Page-214 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

1 no. of 3200 amp rating motor operated spring charging four pole ACB (EDO), horizontal
drawout type.The ACB shall be electrically interlocked covering 24V DC shunt trip circuit,
under voltage circuit & closing with Transformer and DG incomers .The panel shall be
suitable for operation on AMF. The breakers shall be provided with following:-

TNC breaker control switch.


6 Outgoing Panels
All outgoing ACB panels shall be provided with DN -1 release and MCCB Panels shall be
provided with thermal / magnetic release and one set of ON/OFF indication lamps with
protection MCB, and Ammeter of suitable range with Ammeter selector switch and CT's as
required.

a Following outgoings shall be on Bus section 1 (transformer no-1)

i 1250A 4P ACB (MDO) ------------------1 No.


ii 800A 4P ACB (MDO) ------------------4 Nos.
iii 630 amp, 50KA TP+NL MCCB ----------------- 2 Nos.
iv 400 amp, 50KA TP+NL MCCB ---------------- 2 Nos.
v 200 amp, 50KA TP+NL MCCB ----------------- 2 Nos.
c Following outgoings shall be on Bus section 2 (transformer no-2)

i 2500A 4P ACB (EDO) ------------------ 1 No.


ii 1250A 4P ACB (MDO) ------------------ 1 No.
iii 630 amp, 50KA TP+NL MCCB ----------------- 2 Nos.
iv 400 amp, 50KA TP+NL MCCB ----------------- 2 Nos.
v 200 amp, 50KA TP+NL MCCB ----------------- 2 Nos. board 1
Supply, Installation, Testing and Commissioning of power back with 220 volt AC input & 24
volt DC continuous output suitable for closing / tripping / indication of 7 nos. HT panel boards
with 2 nos. 12 volt each maintenance free batteries of 100 (suitable) AH each, charging unit,
capacitor bank for emergency delivering for trip system complete with suitable capacity of
Ammeter & Voltmeter i/c connections with 2.5 sq.mm FRLS insulated copper conductor cable
etc. as required.
325 A-4 job 1
A-5 CAPACITOR PANEL

Page-215 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

326 Supply, installation, testing and commissioning including design, manufacture at works of 600
KVAR capacitor bank and panel consisting of suitable capacity bank of capacitor units in tier
formation, housed in an integrated cubicle type, indoor type automatic switching 'ON' and
'OFF' control panel with microprocessor based automatic power factor correction panel of
minimum 12 stages, dust and vermin proof hinged and lockable doors complete with
interconnections, bonding to earth and painting (suitable for 415Volts, 3 phase 50 Hz supply
system). Each capacitor panel shall consists of the following:

1 Incoming
1 No. 1250 amp 4P ACB (MDO) with microprossor based relay for O/L & S/C.

2 Indicating panel
i 0-1200 Amp Ammeter with required CT's & selector switch.
ii Phase indicating lamps
iii Indicating lamp for each capacitor unit to indicate that unit is "ON/OFF".

v APFCR Stepped relay with 12 steps.


3 Outgoings
The capacitor bank shall be compresing of 4X100 KVAR ,3X50KVAR &2X 25 KVAR capacity
capacitor unit .
Each outgoing for capacitor units shall be provided with the following:
a TP MCCB, suitable capacity with thermal / magnetic release and trip setting as required with
heavy duty solid neutral link.
b Capacitor duty contactors of required rating.
c Capacitor units shall be with discharge resistance.
d Push button stations 'RED' and 'GREEN' push buttons for manual operation of capacitors.

e Toggle switches for changing automatic to maual operation of capacitors.

f Terminal blocks for terminating outgoing connections.


g All interconnections from the bus bars to MCCB and MCCB to contactor and contactor to
terminal blocks. panel 2

A-6 BUS DUCT

Page-216 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

327 Supply, installation, testing and commissioning including design, manufacture at works of
sheet steel enclosed sandwitched 3200A, 65KA TPN "AL" bus duct (IP-55) suitable for 415
V, 3 phase 4 wire 50 Hz AC supply system for indoor installation complete with bends ,
expansion joints, fire barriers ,copper flexible end connection at both ends , insulating
materials, all mounting accessories, necessary steel structure support with down rods, dash
fastner etc. complete as required and as per specifications including two runs of copper earth
bus of size 25X5 mm strips etc. as required from transformer to LT panel.

metre 65
328 A-7 Supply, installation, testing and commissioning including design, manufacture at works of
sheet steel enclosed sandwitched 2500A, 50KA TPN "AL" bus duct (IP-55) suitable for 415
V,3 phase 4 wire 50 Hz AC supply system for indoor installation complete with bends ,
expansion joints, fire barriers ,copper flexible end connection at both ends , insulating
materials, all mounting accessories, necessary steel structure support with down rods, dash
fastner etc. complete as required and as per specifications including two runs of copper earth
bus of size 25X5 mm strips etc. as required from LT panel to AC plant and from DG Set to
DG Incommer Panel.

metre 50
A-8 Auxiliary AC supply panel for ESS
329 Supply, installation, testing and commissioning of LT panel boards of 2mm thick sheet steel
cubical design for indoor mounting factory fabricated suitable for operation on 440V 3 phase,
50 Hz, AC supply with MCCBs / MCB and other accessories complete in all respects
including internal wiring, lables, ferrules, cable termination gland plates, earth terminals,
painting etc. conforming to specification. All MCCB shall be with rotary handle.

INCOMING:-
One No. 200A. TPN MCCB 35KA
BUS BAR:-
one set of 250Amps. TPN busbars of aluminium alloy with coded heat PVC shrinkable
sleeves.
OUTGOING:-
3 Nos. 63Amps. TPN MCCB
3 Nos. 40 Amps. TPN MCB
INDICATION:-
3 Nos. LED type phase indicating lamps with protection 2A SP MCBs

Auxiliary panel complete as required with details described as above and as per
specifications. panel 1

Page-217 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

SUBHEAD -B HT/LT CABLE, CABLE TERMINATION & CABLE TRAY


B-1 H.T. CABLE
330 Supply and laying / fixing of followig size of 11 KV XLPE insulated aluminium conductor
earthed and armoured cable conforming to IS 7098 (Part -II) complete as required in ground,
including excavation ,sand cushioning & brick cover or on surface or on cable tray.

a 3 Core, 300 sq.mm metre 350


b 3 Core, 185 sq.mm metre 50
B-2 H.T. CABLE TERMINATION

331 Supply & making Indoor cable end termination with heat shrinkable cable termination kit with
all accessories including crimped cable lugs suitable for the following sizes of three core
XLPE aluminium conductor cable of 11KV grade as required.

a 3 Core 300 sq.mm each 4


b 3 Core 185 sq.mm each 4
B-3 LT CABLES

332 Supply of following sizes of 1.1 KV grade multicore aluminium conductor XLPE insulated and
PVC sheathed armoured cable conforming to IS 1554 (Part-I) 1988.

a 3.5 Core, 400 sq.mm. XLPE AluminiumCable metre 120


b 3.5 Core, 300 sq.mm. XLPE AluminiumCable metre 900
c 3.5 Core, 240 sq.mm. XLPE AluminiumCable metre 450
d 3.5 Core, 185 sq.mm. XLPE Aluminium. Cable metre 1700
d 3.5 Core, 120 sq.mm. XLPE Aluminium. Cable metre 250
e 3.5 Core, 95 sq.mm.XLPE Aluminium Cable metre 30
B-4 LAYING/FIXING OF 1.1KV GRADE CABLES
333 Laying and fixing of one number XLPE insulated and PVC sheathed armoured power cable
of following size of 1.1 KV grade on surface or cable tray etc as required.

Size 3.5 C, 120 sq.mm. to3.5C 400 sq. mm XLPE AluminiumCable metre 50

334 B-5 Laying and fixing of following sizes of one number XLPE insulated and PVC sheathed
armoured power cable of following size of 1.1 KV grade directly in ground including
excavation, sand cushioning, protective covering & refilling the trench etc. as required.

Size 3.5 C, 120 sq.mm. to3.5C 400 sq. mm XLPE AluminiumCable metre 2000
335 B-6 Laying and fixing of one number additional XLPE insulated and PVC sheathed armoured
power cable of following size of 1.1 KV grade directly in ground including excavation, sand
cushioning, protective covering & refilling the trench etc. as required.

Page-218 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

Size 3.5 C, 120 sq.mm. to3.5C 400 sq. mm XLPE AluminiumCable metre 1200
336 B-7 Laying of one number XLPE insulated and PVC sheathed armoured power cable of following
size 1.1 KV grade in existing masonary open duct / pipe etc. as required.

Size 3.5 C, 95 sq.mm. to3.5C 400 sq. mm XLPE AluminiumCable metre 200

B-8 END TERMINATIONS OF 1.1KV CABLES


337 Supply and making cable end termination with brass compression glands and crimped
aluminium lugs following sizes of PVC sheathed / XLPE aluminium conductor cable of 1.1 KV
grade of the following sizes as required.

a 3.5 Core, 400 sq.mm. XLPE AluminiumCable each 4


b 3.5 Core, 300 sq.mm. XLPE AluminiumCable each 8
c 3.5 Core, 240 sq.mm. XLPE AluminiumCable each 4
d 3.5 Core, 185 sq.mm. XLPE Aluminium. Cable each 14
d 3.5 Core, 120 sq.mm. XLPE Aluminium. Cable each 4
e 3.5 Core, 95 sq.mm.XLPE Aluminium Cable each 2
B-9 CABLE TRAY / RCC PIPE
338 Perforated type Cable Tray
Fabricating and installing fllowing size of perforated MS cable trays including horizontal and
vertical bends, reducers, tees, cross members and other accessories as required and duly
suspended from the ceiling with MS suspenders and including painting etc. as required

a 600 mm width x 50 mm depth x 2.0 mm thickness metre 30


b 450 mm width x 50 mm depth x 2.0 mm thickness metre 40
c 300 mm width x 50 mm depth x 1.6 mm thickness metre 20
339 B-10 Providing and laying non-pressure NP2 class (light duty) RCC. Pipes with collars jointed with
stiff mixture of cement mortar in the proportion of 1:2 (1 cement:2 fine sand) including
excavation ,laying testing of joints & back filling etc. complete.

a 250mm dia . RCC pipe metre 50


b 300mm dia. RCC pipe metre 80

B-11 CONTROL CABLE


340 Supply and laying / fixing of followig size of 1.1 KV PVC insulated Copper conductor
armoured cable conforming to IS 1554 (Part -I) complete as required in ground, on surface or
on cable tray.
a 2X1.5 sq.mm metre 100
b 4X 1.5 sq.mm metre 150
c 8X 1.5 sq.mm metre 80

Page-219 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

SUBHEAD -C SAFETY EQUIPMENT


341 C-1 Supply & erecting/fixing of the following items in the substation.
a Rubber hand gloves suitable for 11 KV. pair 2
b Shock treatment chart both in Hindi & English for treating person suffering due to electric
shock duly framed with 5 mm thick glass and mounted on wall .
each 4
c Safety Instruction chart both in Hindi & English duly framed with 5 mm thick glass and
mounted on wall as required. each 4
d Providing & Fixing HT danger notice plate of 250 mm x 200mm, made of mild steel, at least
2mm thick & vitreous enamelled white on both sides and with inscription in signal red colour
on front side as required.
each 5
e Providing & Fixing MV danger notice plate of 200 mm x 150 mm, made of mild steel, at least
2mm thick & vitreous enamelled white on both sides and with inscription in signal red colour
on front side as required.
each 5
f Carbon dioxide fire extinguishers of 4.5 kg each mounted on wall hooks as per IS : 2878-
1976 complete with all accessories. each 15
g Chamical foam type fire extinguishers of capacity 24 liters trolly mounted as required.
each 4
h G.I. Fire buckets 13 litre capacity filled with dry sand and fixed on wall on hook made out of
13mm dia MS rod & conforming IS 2546 - 1974. each 4
i First aid box containing material as prescribed by St. John Ambulance brigade OR Indian
Red Cross complete as required. each 1
j Rubber mat 1000 mm wide and 12 mm thick to withstand 15 KV dielectric strength as per IS
5424- 1969. each 10
k Rubber mat 1000 mm wide and 6 mm thick to withstand 3.3 KV dielectric strength.
each 25

SUBHEAD -D EARTHING
342 D-1 Earthing with copper earth plate 600mm x 600mm x 3 mm thick including accessories and
providing masonary enclosure with cover plate having locking arrangement and watering pipe
etc. (but without charcoal and salt) complete as required and as per IS-3043 .
set 8
343 D-2 Extra for charcoal and salt for GI plate or copper plate earth electrode as required.
set 8
344 D-3 Providing & fixing of 50mm x 5 mm copper strip on surface for earth connection as required.
metre 5
345 D-4 Providing & fixing of 25 mm x 5 mm copper strip in 40mm dia GI pipe from earth electrode as
required. metre 80
346 D-5 Providing & fixing of 25mm x 5mm Copper Strip on surface or recess for earth connection as
required. metre 100

Page-220 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

347 D-6 Supply and laying of 6 mm dia. G.I. Wire with LT cables for earth connection as required.
set 6700

PART - II (EXTERNAL LIGHTING)


SUBHEAD -A HIGH MAST, POLES & FITTINGS
348 A-1 Supply of Raising & Lowering type 16M high mast system with following: (Bajaj / Philips /
Crompton Make).
a Mast shaft shall be in two sections, hot dip galvanised, inside and outside in singledip,
suitable for wind velocity as per IS 875 part 3. There shall be only one longitudinal seam weld
per section and no circumferential weld. It shall also include accessories for high mast
including head frame, 2-point suspension system with steel wire rope 6mm dia (7/19
construction) double drum winch, Galvanished Lantern carriage arrangement suitable for up
to 12 luminaires symmetrically, lightning finial and integral power tool for raising and lowering
operation of the High Mast.

b Supply of foundation bolts manufactured from special steel along with nuts, washers, anchor
plates and templates.
c Suppy of Non-integral flood light luminaire IP-65 with 2x 400W SON Lamps and its control
gear boxes - 6 Nos.
d 400W Helogen light fitting - 2 Nos.
e Supply of twin dome aviation obstruction lights LED Type - 1 No.
f Supply of control panel housing suitable control circuit for switching ON and OFF of the mast.
It shall also have suitable controls for operation of Power Tool.

g Construction of suitable shallow foundation with 'M20' grade concrete for the high mast
considering the safe soil bearing capacity at site as 10 T/sqmtr at 2mt depth, suitable DWC /
PVC pipe laid within the foundation for incomming and outgoing cables with all materials and
labour.

h Erection of High Mast with help of suitable equipments and wiring of luminaires with all wiring
material and labour.
i Provision of GI pipe earthing for High Mast with 4.5M long 40mm dia GI pipe including
connection of High Mast earth terminal with 25 x 3mm GI flats with all materials and labour.

j Installation of control panel on suitable foundation including all materials and labour.

h Testing and Commissioning of above High Mast system. each 3

Page-221 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

349 A-2 Supplying, Installation, Testing and commissiong of 7.5mtr high MS decorative type steel
tubular pole with single bracket 500mm, duly primed and painted. The pole shal be painted
with MRF polyurethane paint of approved colour. The bottom and middle embellishments are
cast in iron and fixed to the column by grub screw. The column shall be provided with inbuilt
loop box with 4 way 32Amp Heavy duty connector, 2 Nos SPMCB's with wiring from MCB to
fitting with 3x2.5 sq.mm PVC insulated sigle core wires and shall have matching flush
door,fabricated painted complete with RCC foundation including 4x16mm dia foundation bolts
of 300mm length suitable DWC / PVC pipe laid within the foundation for incomming and
outgoing cables as per the Department's requirement. (Keslec / Twinkle / Bajaj / Hilite Make).

a Top dia - 76mm. Length 6000mm


b Bottom dia - 139mm. Length 1500mm
c Base plate - 300 x 300 x20mm thick duly welded in column.
d RCC foundation 600 x 600 x 1200mm each 43
350 A-3 Supplying, Installation, Testing and commissiong of decorative 3.5 long MS tubular pole light
pole standard pole fabricated out of 70 mm dia. pipe 2.0 metre long and bottom dia of 140
mm 1.5 meter long complete with 300 mm x 300 mm x 6 mm thick MS plate welded at bottom
including wiring with 3x2.5sqmm copper wire from JB to light fitting, connections etc. as
required. Welding of 1 no. earth stud and drilling holes for drawing the wire etc. complete as
required including cement concrete foundation, wiring and connections . A looping/ junction
box shall be inbuilt into the pole.

each 39

351 Supplying, Installation, Testing and commissiong of 70 watt MH Post Top lanteran fitting with
70 watt MH lamp, heavy duty copper wound ballst and accessories.
Philips Post Top decorative liminaire HPS360 1x MHN TD 70 W or simillar equivalent make
as approved.
A-4 a each 39
Supplying, Installation, Testing and commissiong of Post top lantern fixture with 70W SON
LAMP, integral control gear, Philips HPS 360 1x SON 70 or other equivalent make as
approved external light fixtures on gate complete as required with GI pipe support / bracket &
all accessories including control gear, lamps, ballast as required.
b each 5

Page-222 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

Supply,Installation,Testing and Commissioning of IP:66 street light luminaries made out of


die cast Aluminium housing and head frame, powder caated in approved color, high purity
Aluminium pot reflector electrochemically brightened and anodized, heat resistant and
toughened glass cover, gasket including accessories like copper ballast, electronic igniter, PF
improvement Capacitor, duly wired as required (Similar to SGP 398 of Philips).

352 A-5
With CDMT 150W lamp. each 43

SUBHEAD -B CABLES
Supply of following sizes of 1.1 KV grade multicore aluminium conductor XLPE insulated and
PVC sheathed armoured cable confirming to IS 1554 (Part-I) 1988.
353 B-1
a 3.5x95 sqmm XLPE Aluminium Cable metre 450
b 4x16 sqmm XLPE Aluminium Cable metre 1150
b 4x10 sqmm XLPE Aluminium Cable metre 600
b 4x6 sqmm XLPE Aluminium Cable metre 550
Laying of one number PVC insulated and PVC sheathed XLPE power cable of 1.1 KV grade
of size upto 120 sq.mm direct in ground including excavation, sanc cushioning, protective
covering and refilling the trench etc. as required.
354 B-2 metre 2700
Supplying and making end termination with brass compression gland and aluminium lugs for
following sizes of aluminium conductor cable of 1.1KV grade as required:
355 B-3
a 4 x 16 Sqmm each 92
b 3.5 x 95 Sqmm each 4
b 4x10 sqmm XLPE Aluminium Cable each 48
b 4x6 sqmm XLPE Aluminium Cable each 44

SUBHEAD -C FEEDER PILLARS & EARTHING


Supplying, Installation, Testing and commissiong of floor mounting, totally enclosed,
compartmentalized, cubical, dust, vermin proof and outdoor type ROAD LIGHTING PILLAR
fabricated out of 2mm thick cold rolled carbon anealed, sheet steel, intermnally strengthened
with angle iron frame work with following incoming and outgoing feeders (fabricatedout of
2mm CRCA sheet steel) including supplying and mounting and making connectins /
interconnections with lugs / glands crimping tools, testing and commissioning of following
items inside the panel:-

356 C-1
Incoming
100A TPN MCCB(25KA) 1 No.

Page-223 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

63A, 4P Contactor 1 No.


Time Switch with daily dial suitable for operation on 230V single phase 50Hz AC supply
1No.
Auto Manual Selector Switch 1 No.
Bus Bars
TPN bus bar of 100A rating
Outgoings
20A TP MCB 9 Nos.
Indication lamps (LED Type) 3 Nos. each 2
Earthing with G.I. Earth pipe 4.5m long 40mm dia including accessories and providing
masonary enclosure with cover plate having locking arrangement and watering pipe etc
(but without charcoal or coke and salt) complete as required.
357 C-2 set 20
358 C-3 Extra for using salt and charcoal for pipe earth electrode as required. set 20
359 C-4 P/F 25 x 6mm GI earth strip in ground :
Supplying and laying 25mm x 6mm G.I. strip at 0.5 m below ground level as strip earth
electrode including soldering etc. as required. metre 80
Providing and fixing GI earth strip 25x 5mm in 40mm dia G.I. Pipes in ground 500mm deep
360 C-5 as required. metre 60
Providing and fixing 6 SWG dia G.I wire on surface or in recess for loop earthing along with
361 C-6 existing cable as required. metre 4500

362 C-4 P/F 25 x 6mm GI earth strip in ground :


Supplying and laying 25mm x 6mm G.I. strip at 0.5 m below ground level as strip earth
electrode including soldering etc. as required. metre 80

Providing and fixing GI earth strip 25x 5mm in 40mm dia G.I. Pipes in ground 500mm deep
363 C-5 as required. metre 60

Providing and fixing 6 SWG dia G.I wire on surface or in recess for loop earthing along with
364 C-6 existing cable as required. metre 4500

PART - III (DIESEL GENERATING SETS)


SUBHEAD - A DIESEL GEN. SETS

Providing installing / testing and commissioning of Diesel Generating Set having prime
power rating of 1500 KVA at 1500 RPM, 0.8 lagging power factor at 415 volts suitable for 50
365 A-1 Hz, 3 phase system and for 0.85 load factor, consisting of the following.

Page-224 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

Diesel Engine : Radiator cooled electric start Diesel Engine four stroke of suitable B.H.P at 1500
RPM for above out put of alternator at 40 Degree Celiues, 50% RH & at 1000 mtr above MSL &
conforming to BS:5514, BS:649/IS:10000, capable of taking 10% overloading for one hour after 12
a hour of continous operation. The engine will be fitted with all the required accessories.

b Engine Instrument Panel fitted with and having Digital display for the following.
i Start-Stop switch
ii Lubrication oil pressure indication.
iii Lubrication oil temperature indication.
iv Battery charging indication.
v RPM indication.
vi Over speed indication.
vii Low Lube Oil trip indication.
viii Engine Hours indication.
ix Speed Governor
x Heavy duty air cleaner

Alternator : Synchronous alternator rated at 1500 KVA at 1500 RPM, 0.8 lagging P.F. at 415 volts
suitable for 50 Hz, 3 phase system at 40 Degree Celsius, 50% RH and at 1000 mtr. Above MSL. The
alternator shall be having SPDP enclosure, brushless, continuous duty type, self excited / PMG, self
regulated through AVR. The alternator shall conform to IS:4722 / BS:2613 and will be suitable for
tropical conditions. Class of insulation will be H type. (Space heaters, RTD & BTD alongwith cables
c are covered in this item).

Base Frame & Foundation : Both the Engine & Alternator shall be mounted on suitable base frame
made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete
d foundation and vibration isolation arrangement as per recommendation of manufacturer.

Fuel Tank : Daily service fuel tank suitable for 990 Ltrs capacity, fabricated out of 3mm thick MS
sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with
MS class 'C' pipes of suitable dia. Complete with valves, level indications and accessories as required
e as per specification.
Exhaust System : Dry exhaust manifold with residential grade silencer & catalytic converter,
f stainless steel bellows.
Starting System : DC starting system comprising of starter motors, voltage regulator and arrangement
for initial excitation complete with suitable 2 No. 12 V, 180 AH or more capacity, dry type,
g maintenance free VRLA batteries.

Page-225 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

Accoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the
engine and alternator, extraction, discharging hot air into the atmosphere as per
h specifications. set 2

Providing, laying, testing and commissioning of welded black M.S.Exhaust pipe of following
sizes conforming to IS:3589, cut to required lengths and installed with all joints, providing and
fixing in position necessary fittings like bends, reducers, tees, couplers, necessary supports &
clamps, flexible connections, antivibration mountings, hangers, including insulation, with 50
mm thick mineral wool/rock wool of density not less than 46 kg /cubic meter , wire mesh
366 A-2 and 24 SWG Aluminium Cladding etc. as required as per specifications .
a 350mm dia. 5.2mm thick metre 75
b 250mm dia. 5.2mm thick metre 40

PCCM based DG Auto synchronization, Auto Load Management, Auto load sharing control
367 A-3 logic panel. (Micrologix, PLC Based) comprising of the following:
Engery analyzer with RS 485 port
Battery charges (with trickle and boost charging)
DC Voltmeter and Ammeter
Engines Cranking Relay
Main Supply Voltage Monitor
Auxiliary Relays, Timer, Push Button and Control MCCB's
Trip Circuit Supervision Relay
Master Lock Out Relay

12 Windows Alarm Annunciator with Separate Hooter, Accept Rest and Rest Push Button
Set Running Indicating Lights : 230 volt
DG Start Stop Push Button
Time Totalizer
Voltage Monitor for DG Supply
Voltage Monitors for Main Supply
Selector Switch Auto / Manual
Selector Switch DG Selection
8 Channel Scanner
Windows based Operator Interface Grafix Software for Monitoring
CPU (Allen Bradley / Siemens / ABB / Schneider) with desk.
Power Supply Module

2 KVA, single phase input and single phase output, 240 volts, 50 Hz, AC, online UPS with
inbuilt 30 minutes battery backup in form of sealed maintenance free batteries with power
wiring to the control bus for power supply to relays. (To be installed inside the panel).

Page-226 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

Auxiliary relays for Output Command


PC with P-IV Intel Processor, 80 GB Hard, 1 GB RAM, 15" TFT Colour Monitor PCI-VGA card
2 MB, DVD Driver (reader and writer)
Priming Pump Starter with priming timer of PIC make (DOL-2HP)
Micrologix - 1500 (PLC)
KW Transducer
Earth Fault Relay

The Synchronizing System shall be provided with following feature and audible alarm:
Engine Starter Control
Speed Monitoring
Over Speed Protection
Oil Pressure Monitoring, Alarm and Shutdown of the Engine
Water Temperature Monitoring, Alarm and Shutdown of the Engine.
Battery Voltage Monitoring
3 attempt start failure alarm
Under / Over Frequency
Reserve Power (inverse time delay)
Over Current (inverse time delay)
Loss of Utility Power Detection
Load Surge
Current Unbalance
Voltage Unbalance
Configurable Loading / Unloading Ramp Rates
Base Load Control for Optimum Fuel Efficiency Set 1
A-4 Exhaust System

Page-227 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

Supplying the necessary materials and making support tower for Exhaust chimney for D.G
Sets including Design and preperation of the drawings for exhaust chimney with provision of
sampling ports for all types of stacks, submission and obtainign approval and necessary
certificate from pollution control board and other statutory authorities.
Exhaust chimney shall be taken upto height of min. 30mtrs above ground level and shall
conformed to the statutory regulatins by Environment authorities and shall be as per
specificatgions. Structural design of support structure shall also be in the scope of contractor
that will include all concrete foundation including excavatin and disposal of surplus earth,
steel reinforcement, ladder for all connected works including lightening arrester, earthing and
2 Nos. aviation obstruction lights.
The chimney shall be self supporting type and shall include and support necessary holding
down bolt arrangements. The civil and steel structural works required for the chimney is also
included in the scope. The sports structure and chimney shall follow specifications in the
368 attached Annexure.
a Steel Fabrication (Welded M.S) Kg 12 000
b RCC Foundation Cum 100
A-5 M.S Tank (Bulk Storage)

Supplying, installation, testing and commissioning of M.S Tank 20KL capacity fabricated out
of 6mm thick M.S Plate with bracing's inside for providing strength to sheet metal work,
complete with all standard apparatus / mountings like manhole of 600mm dia and cover duly
hinged, access ladders, lifting lugs, earthing bolts etc. Dish ends of 8mm thick M.S sheet, fuel
fill pipe 80mm dia with locking arrangement, vent pipe, outlet pipe Brass dip stick, with
calibrater chart (As per IS Code 10987 - 1992 Tank fabricated from MS sheet of 6mm
thickness and two level indicators. The tank shall be duly painted with two coats of tank
mastic and two coats of Tar Plastic paints outisde of tank and any other treatment required
for corrosioin resistance as per standar practice and requirement. Tank shall be provided with
level switches High / Low.

369

Page-228 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

The rates quoted shall be complete with connected civil work including excavation, half round
RCC foundation as required, completes with foundation bolts and strapings duly anchored to
foundations, sand fill, disposal of surplus earth, debris as required for installation of tank
including fire fighting system, security fencing, etc as required liassioning with corcerned
Govt. Authorities and NOC from D.M (DC) and local Authorities getting permission shall be
contractors responsibility. Tank to be hydrallicaly tested to meet requisite standard / 3m water
columns head whichever is higher. Certificate to the above affect is required . Any other
functinal requirement as per site condition shall also deem to have been included in the
scope fo this item. set 1
A-6 Buffer Tank & Overflow Tank

Supplying, installation, laying, testing and commissioning of Buffer Tank of 990 Ltr. Capacity,
over flow tank of 990 ltr capacity, fuel transfer pumps, strainers, valves, pipes, bends,
supports, clamps complete as shown in the Line Diagram including cost of hydraulic testing
370 with valves, strainers and adopter complete as required.
i 990 Ltr capacity tank fabricated out of 3mm, thick MS Sheet - 2 Nos.
Fuel transfer gear type pump set coupled with single phase flame proof motor capable of
ii delivering.
a). 50 LPM (from U/G tank to day oil tank) - 2 Set
b). 35 LPM (from overflow tank to U/G tank) - 2 Set
iii Push Button Station for fuel transfer pump sets - 4 Set
iv M.S Pipe (C-Class) quantities shall be as per site requirements.
a 80mm dia
b 50mm dia
c 40mm dia
d 25mm dia
v Pipe Accessories
a 80mm adopter suitable for oil company delivery hose - 1 No.
b 80mm brass ball valves - 5 Nos.
c 80mm strainer with SS Screen 80/100 mesh - 1 No.
d Oil recording thermometer (mechanical type) - 1 No.
e Pressure guage with siphon and guage cock - 1 No.
vi Ball - Valves
a 50mm dia - 8 Nos.
b 25mm dia - 7 Nos.
vii Foot Valve
a 50mm dia - 2 Nos.
b 25mm dia - 1 No.
viii Non Return Valve

Page-229 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

a 50mm dia - 2 Nos.


b 25mm dia - 2 Nos.
ix Y-Strainer
a 100mm dia - 1 No.
b 50mm dia - 2 Nos.
c 25mm dia - 2 Nos.
x Cables (quantity shall be as per site requirement)
a 3C x 4 sqmm Cu conductor
b 3C x 2.5 sqmm Cu conductor
c 12C x 2.5 sqmm Cu conductor
d 3C x 1.5 sqmm Cu conductor set 1

Note: - The schematic drawing showing bulk storage tank, buffer tank, overflow tank, pipes, valves
ect. In addition to BOQ, if there is any functional rquirement / alteration as per the requirement at site,
the same shall to be executed without any cost implication. Location of buffer tank and over flow tank
shall be in DG Room / Sub-Station Room and loation of bulk storge tank shall be at a distance of 15m
(approx.) from DG Sets.

Fabricating and installing following sizes of perforated M.S. cable tray including horizontal &
vertical bends, reducers, tees, cross members and other accessories as required duly
371 B-1 suspended from ceiling with M.S. Suspenders, including painting etc. as required.
a 300mm width x 50mm depth x 2mm thick metre 30
b 150mm width x 50mm depth x 1.6mm thick metre 30
Total Subhead B

Earthing with copper Earth Plate 600mm x 600mm x 3mm thick I/c accessories and providing
masonary enclosure with cover plate having locking arrangement and watering pipe etc. (but
372 C-1 without charcoal or coke and salt) complete as required. set 4

373 C-2 Extra for using charcoal / coke and salt for GI or copper plate earthing electrode as required. set 4
Providing and fixing 25mm x 5mm copper strip in 40mm dia GI pipe from earth electrode as
374 C-3 required. metre 20
Providing and fixing 25mm x 5mm copper strip on surface or in recess for connection etc. as
375 C-4 required. metre 30

3 FIRE PUMPS, VALVES & ACCESSORIES


Supply, Testing, Installation, Testing & Commitioning of Electrical Motor Driven Fire
Pumping set suitable for automatic operation consisting of the following as per the
376 3.1 specifications.

Page-230 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

Providing and fixing horizontal split casing single/multi stage, single pumping set with bronze
impeller with gland capable of delivering 2850 LPM against a total head of 75 M with C.I.
body and connected by a flexible coupling to a totally enclosed fan cooled induction motor
mounted on a common structural baseplates with all pump accessories complete as per
specifications including pressure gauge with gunmetal isolation valves and anti vibration
pump, motor to be suitable for 415 volts, 3 phase, 50cycles A.C. supply( specification as per
fire fighting requirements and on the pattern of TAC OR LOCAL AUTHORITY APPROVAL)
as per instruction of following specifications:

b) Squirrel cage induction motor totally enclosed fan cooled type suitable for 415 volts ±15%,
3 phase, 50 Hz AC supply of suitable capacity (approximate 60 KW) for the above pump
coupled with flexible coupling including earthing as per relevant Indian standard &
specifications.
c) Common bed plate for mounting pump and motor fabricated from suitable MS Channel as
per manufacturer's recommendations.
d) Suitable RCC pump-foundations as per manufacturer's design and 4 nos. dunlop (cushy
foot) heavy duty antivibration mounting pads. Set 2

Supply, Testing, Installation, Testing & Commitioning. Of Diesel Engine Driven Fire
Pumping set suitable for automatic operation consisting of the following as per
377 3.2 specifications:
Providing and fixing horizontal split casing single multi stage, single pumping set with CI body
and bronze impeller & with gland capable of delivering 2850 lpm against a total head of
75m connected by means of a flexible coupling to a water cooled diesel engine mounted on
a common structural base plate with antivibration pads and and foundation complete with
electric panel, battery (including one spare battery), utomatic starting arrangement exhaust
pipe of required length to discharge outside building with muffer, day oil tank mounted on
suitaible structural supports complete in all respects as per specifications ready for use and
as per latest requirement of fire autority regularities.

b) Water cooled TAC approved Diesel Engine suitable for developing at least 60 BHP at 1800
RPM) compatible for above pump complete with automatic starting mechanism, batteries,
automatic battery charger unit, flexible coupling with the pump, fuel tank, silencer, exhaust
pipe with insulation approx. 25m length & all standard accessories as required as per TAC
rules including earthing, mandatory spares and tool kit.

Page-231 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

c) Common bed plate for mounting pump and engine fabricated from suitable MS Channel as
per manufacturer's recommendations.
d) Suitable RCC pump foundations as per manufacturer's design 8 Nos Dunlop Anti-vibration
(cushy foot) heavy duty mounting pads. Set 1

Supply, Testing, Installation, Testing & Commitioning. of Electrical Motor Driven


Automatic pressurisation (Jockey) pumping set consisting of the following as per
378 3.3 specifications.

Providing and fixing horizontal split casing single/multi stage, single/multi outlet pumping set
with bronze impeller & with gland capable of delivering 180 LPM against a total head of 75
M with C.I. body and connected by a flexible coupling to a totally enclosed fan cooled
induction motor mounted on a common structural baseplates with all pump accessories
complete as per specifications including pressure gauge with gunmetal isolation valves and
anti vibration pump, motor to be suitable for 415 volts, 3 phase, 50cycles AC supply
(specification as per fire fighting requirements and on the pattern of TAC OR LOCAL
AUTHORITY APPROVAL) as per instruction of following specifications:

b) Squirrel cage induction motor totally enclosed fan cooled type suitable for 415 volts ±15%
3 phase 50 Hz AC supply of suitable capacity (approx. 15 KW) for the above pump with
synchronous speed of 1500/3000 RPM confirming to IS:325 & duly coupled with above pump
coupled with flexible coupling including earthling as per relevant Indian Standard and
specifications.
c) Common bed plate for mounting Pump and Motor fabricated of suitable M.S.Channel
as per manufacturer's recommendations.
d) Suitable RCC Pump foundations as per manufacturer's design 4 Nos Dunlop Anti-vibration
(cushy foot) heavy duty mounting pads. Set 2

Providing, fixing, testing and commissiong of double flanged vertical air vessel fabricated
from 10mm MS plate with dished ends from 10mm MS plate, outside with one coat of primer
and two coats of synthetic enamel paint of approved shade, complete with approved quality
of pressure switches, pressure gauge and all other required accessories to operate
commonly main fire pump, sprinkler pump and Jockey pump at drop of pressure,
379 3.4 automatically at required pressure setting;
Recommended dia. : 450mm
Height of shell : 2000mm
Working pressure : 7 kg/cm2
Test Pressure : 10 kg/cm2 Each 2

Page-232 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

380 3.5
Providing, fixing, testing and commissiong of motor control centres fabricated from 16 gauges
MS sheet with powder coated finish. The control panels should be comparable with H.P. of
the motor as specified.

Panel for fire pumps

Providing and fixing motor control centres fabricated from 16 gauge M.S. sheet with Powder
Coated finish. The control panels should be compatible with H.P. of the motor as under and
as per spcifications with automatic star delta starters. (One separate panel to be located in
the plant room).

a) One incoming main isolation MCCB TP of Min. 250 Amps. rating.

b)
Fully taped aluminium bus bar of required capacity in a separate bus bar chamber.

c) Isolation MCCB for each unit of required rating and with fully automatic starter as per
requirement with push button and ON/OFF indicating lights for each unit, for following
requirements:
i) One main fire pump of 85 HP.
ii) One main Sprinkler pump of 85 HP.
iii) Two jockey pump of 20 HP (Each).
iv) One Diesel Pump Controlling System

d) Single phasing preventors of suitable rating one for each motor.

e) Rotary type Auto/Manual/ ON/OFF selection switches.

f) One 96 mm square panel type voltmeter reading 0-500 V with rotary selector switch for
reading voltage between phases.

g) One 96mm square panel type Amp. meter reading 0-500 Amp. for main fire pump and
sprinkler pump.

h)
One 96mm square panel type Amp. meter reading 0-500 Amp. for each Jockey pumps.

i) Appropriate etched plastic plate for each starter/switch.

Page-233 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

j) Colour coded internal wiring from incoming main to bus bar, switch gear, starters, meters
indicating lamp etc., complete in all respects. set 1
(Complete set included item (a) to (j).

381 3.7
Providing and fixing resilient rubber neoprene lined single arch vibration eliminators suitable
for raw water upto 450C temperature working pressure 7 kg/cm2 and test pressure 14 kg/cm2
with unit control.
3.7.1 50 mm dia Each 2
3.7.2 65 mm dia Each 4
3.7.3 80mm dia Each 6
3.7.4 100mm dia Each 4
3.7.5 150 mm dia Each 4

382 3.8 Providing and fixing CI double flanges suction strainer (PN 2.0) “Y” type including, nuts, bolts
and 3mm thick rubber insertion complete.
3.8.1 80mm dia Each 1
3.8.2 100mm dia Each 1
3.8.3 150mm dia Each 3
3.8.4 200mm dia Each 2

383 3.9
Providing and fixing brass/bronze lever operated ball valve of full flow with stainless steel ball
(AISI 304 and spindle AISI 410) with setting and gland of superior quality having minimum
working pressure of 20 kg/cm2.
3.9.1 15mm dia Each 1
3.9.2 20mm dia Each 1
3.9.3 25mm dia Each 4
3.9.4 32mm dia Each 1
3.9.5 40mm dia Each 2
3.9.6 50mm dia Each 3
3.9.7 65mm dia Each 4

384 3.10
Providing and fixing butterfly valves, wafer end type class PN 1.6 as per IS: 13095-1991 or
BS: 5155, including necessary nuts, bolts, gaskets etc. complete (without gear box)
3.10.1 80mm dia nominal bore. Each 2
3.10.2 100mm dia nominal bore. Each 4
3.10.3 150mm dia nominal bore. Each 6
3.10.4 200mm dia nominal bore. Each 2

Page-234 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

385 3.11
Providing and fixing CI double flanged horizontal/ vertical type non-return valve including
nuts, bolts, 3mm thick rubber insertions complete to IS:5312, part-I, swing type, class PN 1.6.
3.11.1 65mm nominal bore Each 2
3.11.2 80mm nominal bore Each 2
3.11.3 100mm nominal bore Each 4
3.11.4 200mm nominal bore Each 2

386 4
Providing, fixing,testing and commissiong of standard mild steel flanges, (only in valves,
strainers, expansion joint and pumps matching flanges) screwed or welded complete with
1.5mm thick compressed asbestos gasket, nuts, bolts and washers etc., complete including
testing of joints. The flanges shall be as per IS 6392 table E.

a) 200mm dia Each 10

b) 150mm dia Each 12

c) 100mm dia Each 10

d) 80mm dia Each 30

e) 65mm dia Each 27

f) 50mm dia Each 20

387 5
Providing, fixing of G.I. earthing wire 8 SWG from all motor and MCC panels to be connected
in a approved manner to the general earthing system complete. Metre 175

Providing and fixing G.I. Earthing strip of Size 25 x 3mm for higher size motors and MCC
388 6 panels to be connected in as approved manner to the general earthing system complete. Metre 200

Providing earthing station with GI Earthing Plate for pumps and MCC panels including
389 7 excavation, CI manhole cover and frame complete as per specifications and IE rules. Each 8

Providing and fixing pressure switch (for operation at 0-15 kg/cm2) with required fittings and
390 8 accessories complete. Each 5
Total Price of Section C

Page-235 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

SECTION- D- Pumps, Water Treatment & Allied Equipment


Raw Water Pump (P-1)

Providing, fixing, testing & commissioning of horizontal split casing multistage centrifugal
pumping set with stainless steel SS-304 stage casing and SS304 impellers with stainless
steel SS304 shaft as per IEC standards and GJL250 cast iron suction & discharge casing,
connected to TEFC ventilated induction motor of 2 pole, 2900 RPM, suitable for 400/440
volts, 3 phase, 50 Hz AC supply with pressure gauge and with gunmetal isolation cocks,
vibration elimination pads etc. complete with base and frame, nuts and bolts and necessary
391 1 RCC foundations as per requirement as per instructions and pump shall have following duty.
No. of Pumps : 3 (2 working + 1 stand by )
Capacity : appox. 760 LPM
Head : 30m
Model :- DPVF 45-20 , 7.5 Kw Each 2

a) (For Domestic Water Supply)


Pump No. P - 2
No. of Pumps : 2 (1 Working + 1 Stand by)
Capacity : app. 300 LPM
Head : app. 64 M
No. and capacity of Pressure Vessel – 2 Nos. x 450 Ltrs Set 1
Model :- DPVF 18-60 , 5.5 Kw

b) (For Flushing Water Supply)


Pump No. P - 4
No. of Pumps: 2 (1 Working + 1 Stand by)
Capacity : app. 130 LPM
Head : app. 64 M
No. and capacity of Pressure Vessel – 1 Nos. x 450 Ltrs Set 1
Model :- DPV 10-70 , 3 Kw

392 2 Soft Water Pump

Page-236 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

Providing,fixing, testing & Commissioning of horizontal split casing multistage centrifugal


pumping set with stainless steel SS-304 stage casing and SS-304 impellers with
stainless steel SS-304 shaft as per IEC standards and GJL250 cast iron suction & discharge
casing, connected to TEFC ventilated induction motor of 2 pole, 2900 RPM, suitable for
400/440 Volts, 3 phase, 50 Hz A.C. supply with pressure gauge and with gunmetal isolation
cocks, vibration elimination pads etc. complete with base and frame, nuts and bolts and
necessary RCC foundations as per requirement as per instructions and pump shall have
following duty:
No. of Pumps: 2 (1 Working + 1 stand by)
Capacity : app 50 lpm per pump
Head : app.30m Each 2
Model :- DPVE 2-60 , 0.75 Kw

393 3 Garden Hydrant Pumps

Providing,fixing, testing & Commissioning of Horizontal split casing multistage centrifugal


pumping set with stainless steel SS-304 stage casing and SS-304 impellers with
stainless steel SS-304 shaft as per IEC standards and GJL250 cast iron suction & discharge
casing, connected to TEFC ventilated induction motor of 2 pole, 2900 RPM, suitable for
400/440 Volts, 3 phase, 50 Hz A.C. supply with pressure gauge and with gunmetal isolation
cocks, vibration elimination pads etc. complete with base and frame, nuts and bolts and
necessary RCC foundations as per requirement as per instructions and pump shall have
following duty:
No. of Pumps : 2 (1 Working + 1 stand by)
Capacity : app. 350 lpm
Head : app. 30 m Each 2
Model :- DPVF 32-20 , 4.0 Kw

394 4 Pressure Filter (Domestic Water)

Providing,fixing, testing & Commissioning of vertical Dual Media Pressure Filter (comprising
of 300mm bed depth of graded sand gravel and 600mm bed depth of Anthracite and min.
900mm freeboard) fabricated from high performance M.S plate of minimum 10mm thick for
shell & 12mm thick for dished ends (Quality of steel as per IS:2002 Grade A, Fabrication to
be as per IS:2825) having perforated bed-plate (14mm Thick) collection system complete
with initial charge of filter media, M.S face piping, valves, accessories, painting, testing and
commissioning complete. (Tested to 6 kg/m2)
Discharge : 45,127 lph per filter

Page-237 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

Filtration Rate : 17,500 lit./m2/h


Suggested dia app. : 1.35 m Each 1

395 5 Water Softener

Providing, fixing, testing & Commissioning of ‘Cation’ water softener fabricated as per IS
2825 from minimum 8mm thick MS plate on shell and 10mm thick MS plate on dished ends
complete with initial charge of filter media and resins, face piping accessories, diaphragm
valves, HDPE Brine tank of min. 250 Liters with electrically operated stirrer, piping testing and
commissioning complete with resins of approved quality and make and regeneration
assembly complete with valves, ejector, brine suction valves and piping. (Bidder must
indicate type and quantity of resin used and quantity of salt required per regeneration). All
internal parts of the softener shall be epoxy coated as per approved specifications.
Minimum expected rate of flow: 12500 lph

Total soft water to be produced between two regenerations: of 8 Hours app 100 KL

Expected raw water hardness : app. 300-400 ppm

Expected treated water hardness: less than 5 ppm


Max. working pressure : 4 kg/cm2 Each 1

Providing,fixing, testing & Commissioning of FRP salt saturator as per requirement and
externally painted with suitable anti-corrosive paint, with all required accessories for holding
and supplying salt for softener complete in all respects with electrically operated stirrer and
396 6 of capacity 1000 litres. Each 1

Providing,fixing, testing & Commissioning of Sump Pumps for lifting water from drainage
397 7 sumps in plant room & basement

Providing,fixing, testing & Commissioning of compact monoblock dry motor submersible


pumps for suitable rating, with non-clog free flow open impeller, minimum solid handling
capacity of 28mm suitable for operation on 415 volts + 5% -15%, 50 C/s A.C single phase
supply, speed 960/1440R&M including oil chamber, guide wire for lifting & lowering of pump,
M.S. galvanized lifting chain, duck foot bend with following specifications:

Page-238 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

The above pump sets must be supplied complete with following accessories.

Complete piping 100mm dia common delivery upto 5m as per enclosed tentative layout. (The
a) pipe should be preferably CI LA/heavy duty G.I) -- 1 Set

b) 80mm dia sluice valve.-- 2 Nos

c) 80 mm dia reflux valve.-- 2 Nos

Necessary cables from pump set to control panel (position of panel marked in enclosed
d) layout in plant room).-- 1 Set

Electrical switch panel having all necessary accessories & safety devices of standard
e) specifications. (Panels with sump pumps near each sump as per site conditions). - 1 No.

f) Automatic built-up water level controller with necessary length of cable upto control panel.

Motor rating - 1.1KW


Discharge - max. 15 m3/hr.
Total head - 10 m
Make - KSB
(Complete set as above with 2 nos. pumps) Set 4
DP Make Pumps model DVV 20-3V

Providing,fixing, testing & Commissioning of G.I. pipes (IS:1239 heavy class) complete with
GI fittings ie tees, elbows, sockets, clamps etc including painting of approved specifications,
MS structural supports and hangers as required (as per approved shop drawings) as per
398 8 instructions of Engineer-In-charge.
a) 150mm dia Metre 50
b) 100mm dia Metre 25
c) 80mm dia Metre 40
d) 65mm dia Metre 25
e) 50mm dia Metre 50
f) 40mm dia Metre 40

Page-239 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

Providing and fixing standard G.I. flanges, (only in valves, strainers, expansion joint and
pumps matching flanges) screwed or welded complete with 1.5mm thick compressed
asbestos gasket, nuts, bolts and washers etc., complete including testing of joints. The
399 9 flanges shall be as per I.S:6392 - 1971 table E.
b) 150mm dia Each 4
c) 100mm dia Each 12
d) 80mm dia Each 5
e) 65mm dia Each 5
f) 50mm dia Each 4

Providing and fixing rubber expansion joints (to provide relief from stresses at pipe flanges)
400 10 as per specification of the manufacturers i.e. M/s Kanwal Industrial corporation,
a) 150mm dia Each 4
b) 100mm dia Each 5
c) 80mm dia Each 5
d) 65mm dia Each 4
e) 50mm dia Each 8

Providing,fixing, testing & Commissioning of C.I double flanges suction “Y” type including,
401 11 nuts, bolts and 3mm thick rubber insertion complete.
a) 150mm dia Each 2
b) 100mm dia Each 1
c) 80mm dia Each 1
d) 65mm dia Each 2

Providing,fixing, testing & Commissioning of butterfly valves, wafer end type class PN 1.6 as
per I.S:13095 or BS:5155, including necessary nuts, bolts, gaskets etc. complete (without
402 12 gear box)
a) 65mm dia nominal bore. Each 8
b) 80mm dia nominal bore. Each 6
c) 100mm dia nominal bore. Each 4
d) 150mm dia nominal bore. Each 6

Providing,fixing, testing & Commissioning of forged brass lever operated ball valve of full
flow with forged brass ball (Machined to mirror smooth finish with hard chrome plated) and
spindle with setting and gland of superior quality having minimum working pressure of 10
403 13 kg/cm2 etc. complete in all respect.
a) 40mm dia Each 10

Page-240 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

b) 50mm dia Each 8

Providing,fixing, testing & Commissioning of gunmetal non-return valves vertical or


404 14 horizontal tested to 20 kg/cm2 as per IS:778.
a) 50mm nominal bore Each 4
b) 65mm nominal bore Each 4

Providing, fixing, testing & commissioning of CI double flanged horizontal/vertical type non -
return valve including nuts, bolts, 3mm thick rubber insertions complete to IS:5312, Part-I,
405 15 swing type, class PN 1.6
a) 80mm nominal bore Each 8
b) 100mm nominal bore Each 4
c) 150mm nominal bore Each 2

Providing, installing, testing & commissioning of motor control centres fabricated from 16
gauges MS sheet with powder coated finish. The control panels should be comparable with
406 16 HP of the motor as specified.

(A) Panel - A
For domestic water relift pumps, soft water pump and raw water pump, auto chemical doser
sump pump etc. in plant room.

a) One incoming main isolation MCCB of required rating.

b) Fully taped aluminum bus bar of required capacity in a separate bus bar chamber.

Isolation switch units with MCCB of required rating, for all Hydro-pneumatic pump control
c) panels, + each unit as per details below

Fully automatic DOL starter with push button and ON/OFF indicating lights for each unit,
d) for following requirements:

i) Raw water filter feed pump 3 Nos. (2 working +1 standby) of required H.P.

ii) Garden pumps 2 Nos. (1 working + 1 stand by) of required HP

iii) Soft water supply re-lift pumps 2 Nos. (1 working + 1 standby) of required HP

Page-241 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

iv) Auto chemical doser of 2 no of 0.5 HP capacity (1 working + 1 standby)interlocking with


raw water pumps of required HP

v) Hydro pumpsets (4 sets) --- only connections to each individual Hydro Built-up Control
Panel.

v) Sump pump (8 Nos.) --- only connections to built-up panel.

e) Rotary switches for auto/manual ON/OFF operations for each unit.

f) Rotary duty selector switches.

g) Panel type voltmeter 150mm with rotary selector switch for reading voltage between phases.

h) Panel type ammeter 100mm square. One for each motors with appropriate range.

i) Neon phases indicating lights on the incoming mains.

j) Single phase preventor for each motor.

k) CT Operated Relay

All internal wiring colour coded from incoming mains to various switchgear, starter, meter,
l) indicating lamp and bus bar. All the cable entry to the panel shall be from the top.
(All for above from item (a) to (l) complete set). (The shop drawing to be prepared and
approved before fabrication) Set 1

Providing,fixing, testing & Commissioning of motor pump controller cum water level
407 17 indicating panel in powder coated sheet metal box in 16 gauges M.S including the following:

i) Electronic water level controller working on magnetic type sensing probes.

ii) Electronic minimum 5-level indicator with magnetic type sensing probes.

Page-242 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

iii) Arrangement of alternate switching mechanism for operational and standby pumps.

(A) For Water level indicators with following details:


i) Underground tanks

Minimum 5 level Multi level indicators with magnetic type sensor probes complete. Each 4

ii) Overhead tanks


Solenoid valve operated level controller with magnetic type sensor with minimum 4 level. In
addition to above heavy duty float valve Each 8

For water level controllers with electronic sensing probe complete in all respect for following
(B) functions.

i) Tubewell Pumps

To start at low level in RW tank and to cut off at high level in raw water tank. Set 2

ii) Soft Water Relift Pumps (1 w+1 s)


To start at low level in soft OH tank, and to cut off at high level in soft OH water tank and to
cut off at low level in UG soft water tank. Set 1

iii) Raw Water Pumps (2 w+1 s)

To cut off at low level in raw water UG tanks and to cut off at high level in UG Domestic and
soft water tank and to cut on at low level in domestic & soft water UG tanks. Set 1

iv) Garden Hydrant Pump (1 w + 1 s)


To cut off at low level in U.G Raw water tank Set 1

Providing,fixing, testing & Commissioning of heavy duty copper armored cables 1.1 KVA
grade including necessary support clamps at ceiling level and connection legs complete in all
408 18 respects.

a) Control cable 6 core 1.5 mm2 Metre 150

b) Control cable 2 core 1.5 mm2 Metre 100

Page-243 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

Providing,fixing, testing & Commissioning of heavy duty Aluminium armored cables 1.1 KVA
grade including necessary support clamps at ceiling level, connection lugs and double
409 19 compression glands, complete in all respects.
a) Power cable 3 core 6 mm2 Metre 200
c) Power cable 3 core 10 mm2 Metre 90
c) Power cable 3 core 16 mm2 Metre 150
d) Power cable 3 core 25 mm2 Metre 80
e) Power cable 3 core 70 mm2 Metre 60
f) Power cable 3 core 95 mm2 Metre 25

Providing,fixing, testing & Commissioning of GI earthing wire 8 gauge from all motor and
MCC panel to be connected in as approved manner to the general earthing system complete.
410 20 Metre 425

Providing,fixing, testing & Commissioning of GI earthing strip of size 25x 3mm for higher size
motors and MCC panels to be connected in as approved manner to the general earthing
411 21 system complete. Metre 350

Providing earthing station for pumps and MCC panel including excavation, C.I. manhole
412 22 cover and frame complete as per specifications and I.E. rules. Each 1

Providing and fixing MS slotted cable tray supported from ceiling at intervals of 60cms on
both ends including cable clips with nuts and bolts welding of support rods with ceiling inserts
413 23 or through dash fasteners cutting and making good complete including painting of cable tray.
a) 300mm wide x 40 x 2 mm Metre 210
b) 150mm wide x 40 x 2 mm Metre 150

Providing and fixing electrical solenoid valves in SS body, for min. working pressure of 10
414 24 kg/cm2, complete with all necessary accessories and electrical devices.
a) 65 mm dia. Each 4
b) 50 mm dia. Each 4
c) 40 mm dia. Each 4

Page-244 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

Providing,fixing, testing & Commissioning of automatic chemical dozing system consisting of


electronic dosing pump, suitable to doze chemical solution as per requirement with a dosing
capacity of (0-12 lph) for dosing of appx. 2 ppm of chemical to a flow of water of 50,000 to
100,000 lph. against a pressure of 50-60 psi complete with FRP moulded solution holding
415 25 tank of 100 litre with all standard accessories. Each 1

Providing,fixing, testing & Commissioning of of Pressure Gauge in SS-316 (glycerine filled)


for min. 0-300 psi round dial of 100mm size with threaded nipple, unions, coupling etc
416 26 including standard fittings. Each 10

4 MISCELLANEOUS

Providing and fixing insect-proof coupling to vent pipes of underground tank with threaded or
417 1 flanged joints, including MS flanges, nuts, bolts, 3mm thick rubber insertions complete.
a) 80mm dia Each 4
b) 100mm dia Each 4

Providing and fixing CI double flanged equilibrium float valve with MS lever high pressure,
418 2 copper ball and flanges including nuts, bolts, 3mm thick rubber insertions complete.
a) 40mm dia Each 4
b) 50mm dia Each 4
c) 65mm dia Each 2

Providing and fixing extra heavy duty 560mm dia, double seal, water tight cast iron manhole
cover and frame for placing over the underground water tanks with lifting and locking
arrangements as per approved sample, complete in all respect including fixing in PCC as per
419 3 site requirement. Nos 10

Page-245 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

Providing orange colour safety foot rest of minimum 6mm thick, plastic encapsulated as per
IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as
23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum
112mm space between protruded legs having 2mm tread on top surface by ribbing or
chequering besides necessary and adequate anchoring projections on tail length on 138mm
as per standard drawing and suitable to with stand the bend test and chemical resistance test
as per specifications and having manufacturer's permanent identification mark to be visible
even after fixing, including fixing in manholes with 30x20x15cm cement concrete block 1 : 3 :
6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20mm nominal size) complete as per
420 4 standard design. (In UG & OHT) Each 250

Supply & fixing of 2 hours Fire Rated door system for Stability, Integrity and Insulation criteria
as per IS 3614 Part-2 and BS 476 Part 22 for single and double leaf doors duly tested from
CBRI Roorkee or from laboratory approved by Engineer in Charge with Hardwood Door
frame of section 145mm x 70mm with heat activated intumescent fire seal strip of size 10mm
x 4mm ( Astroflame U.K./Abesco ) and one coat of anti-termite fire retardant Primer alongwith
55mm thick asbestos free composite fire / smoke check wooden shutters of 120minute fire
rating comprising of two 9mm thick Starpan type of Calcium Silicate Boards, a 100% without
Asbestos, Brucite and Meerschaum, having density not more than 1150 kg/m³ and thermal
conductive 0.14 W/m*K sandwitching 31mm thick fire resistance insulation filler coated with
FR silicon sealant and faced with 3mm thick commercial ply facing on both side with heat
activated thick commercial ply facing on both side and heat activated intumescent fire seal
strip of size 10mm x 4mm ( Astroflame U.K/Abesco ) mounted in the grooves of hardwood
lipping on all sides except bottom. The intumescent sealant is used to fill the gaps between
board and internal wooden lipping, Assa-Abloy's Lockwood Model No.2024/Dorma TS-72
Door-Closers / D-Line, Lockwood D-Type S.S Handle minimum 19mm dia 200mm long /
421 5 Dorma Series / D-Line Series and S.S Ball Bearing Hinges of 304grade size 4'' x 3'' mm. sqm 340

Total Price of Section D

SECTION E- SEWAGE TREATMENT PLANT


NOTE : THE TENDER FOR THIS WORK IS ON THE BASIS OF LUM SUM TURNKEY BASIS. CONTRACTOR MUST INCLUDE ALL ITEMS THAT ARE NECESSARY AND
ESSENNTIAL TO PROVIDE A COMPLETE WORKING PLANT TO THE SATISFACTION OF ENGINEER IN CHARGE.THE BOQ GIVEN HEREAFTER IS ONLY FOR THE

Page-246 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

PURPOSE ASSESSING THE OVERALL COSTING OF THE PROJECT AND WILL BE USED FOR ARRIVING AT THE PAYMENT SCHEDULE TO THE CONTRACTOR.
422 1 Preliminary Works
1 Shop Drawings.

1.1.1 Detailed GA drawing, flow diagram, equipment list, power load requirement Job 1

Design, calculations of all elements of the plant, electrical and mechanical work to satisfy
1.1.2 adequacy of design Job 1

Submission of detailed GOOD FOR CONSTRUCTION' stage architectural, structural,


1.1.3 construction, electrical, mechanical and piping drawing for approval. Job 1

2 SEWAGE TREATMENT PLANT

Design, Supplying, Installing, Testing & Commissioning of Sewage Treatment Plant capacity
2 X 200 KLD. The plant proposed shall be 400 kld . with a common pump room. The
plant is proposed to be installed in the basement accessible from the pump room itself
for future maintenance. No opening shall be provided on main slab above for this
purpose, for the following :

Nature of effluent - Domestic Sewage from Toilet use and kitchen waste.
Daily average flow - 400 Cum / Day
pH - 7.5 - 8.5
BOD5 - upto 250-350 Mg/L
S. Solids - 250 - 400 Mg/L
COD - upto 450-600 Mg/L
Oil & Grease - 50 Mg / L
Effluent discharge standard after treatment
pH - 6.0 - 8.5
BOD5 - Less than 20 Mg/L
S. Solids - Less than 10 Mg/L
COD - Less than 100 Mg/L
Oil & Grease - Nil

Sewage treatment plant shall include the following items:


Screen Chamber
Sewage equalization tank/sump
SAFF tank
Secondary Settling tank
Chlorine contact tank
Treated Water tank

Page-247 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

Sludge Holding Tank


Filtration through MGF & ACF
Air Blowers, Pumps & equipment
Piping, valves etc
Electrical Panel & Cabling
Common plant room adjacent to STP.
Softener as optional
Soft water tank as optional
All piping, valves & level indicator/controller etc. within plant room.

Supply, installation, testing & commissioning of 2 Nos Stainless Steel Perforated Screen with
423 2 suitable lifting arrangement (size 600 mm wide x 400 mm high approx) Set 2

Supply, installation, testing & commissioning of electronic type level indicator and controller
for automatic operation of the system with high/low level alarm complete with auxillary
424 3 NO/NC contacts. Set 1

Contractor shall ensure submission of detailed GA drawings (Plan & Section), P & I diagram,
schematic diagram for the above mentioned components and additional components such as
inserts, puddle flanges, vent pipes etc. if so required for the complete work.

Inlet/Outlet Regulating Gates

Inlet regulating gates fabricated form 16 gstainless steel sheets and angles with sturdy lifting
425 4 arrangements for open position. (Size as per vendor's design)
a) On Equalization Tank Inlets Each 2
b) On Aeration tank inlet /oulet launder
c) On Settling Tank Outlet

Supply, installation, testing & commissioning of non clogging type pumps, having SS casing
& SS impeller complete with all accessories, motor of required capacity. Delivery header with
isolation valve, pressure gauge on delivery line with isolation cock level controller with wiring
426 5 to control the level of sump automatically. Pump shall have following duty.

5.3.1 Submersible Sump Pumps (1 Nos. - 1 working & one standby) :-


(Solid handling cap. 40 mm)
Flow rate (each) = 10-12.0 m3 / hr
Head = 8-10 Mtr Set 2

5.3.2 Plant room sump pump 2 Nos (1 working + 1 standby)

Page-248 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

Flow rate = 10.0 cum/hr


Head = 10 Mts Set 1
(Solid handling size for this pump shall be 15 mm).

5.3.3 Sludge re-circulation Pumps (2 Nos. - 1 working & one standby) :-


(Solid handling cap. 40 mm)
Flow rate (each) = 10-15 m3 / hr
Head = 8-10 Mtr Set 1

Cost shall be inclusive of PVC flexible Hose pipe ( for piping submeged in effluent) with M S
epoxy piping (for piping non-submerged in effluent)

Provision of guide ropes to guide submersible pump from upper level to operational level in
sump basin with channels/angle section of MSEP shall be made by the STP contractor.

427 6 Air diffusion system shall include the following:

Twin type rotary air blowers (one working & one standby) capable of delivering 200 cum/hr
(each) of free air at 0.5 kg/cm2 driven through “V” belt or directly coupled through flexible
coupling to a TEFCmotor of suitable HP Suitable for 415 ± 10% volts, 3 phase, 50 cycles a/c
supply Set 2

Air piping shall comprise of pipes droppers/laterals with M S (epoxy coated) Header complete
with all fittings such as tees, crosses, plugs, sockets, elbows, reducers, supports & clamps,
428 7 puddle flanges etc cutting chases & making good. Lot 1

Non clog type air dispersion system capable of handling 3-5 cfm of air with oxygen transfer
efficiency of 3-4% per/ meter water depth. Air dispersion grid shall be assembled in modular
429 8 form so that they can be replaced/repaired
Fine bubble diffusers
a) For equalization tank -2 Nos. Lot 2
b) For sludge holding tank - 1 No. Lot 1
c) SAFF reactor tank- 2Nos. Lot 2
Air dispersion system shall be provided for Equalisation Tank, Sludge holding Tank and
Note : SAFF reactor Tank.

Providing and fixing all piping (as described below) and isolation control valves for making
430 9 the system complete.
SS 304 :Submerged air piping
MS Epoxy : Air piping

Page-249 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

PVC piping :Pumped effluent & tank overflow pipe line Job 1

Supply, installation, testing and commissioning of PVC bio deck SAFF media to be installed
in SAFF Tanks and PVC tube deck settling media to be installed in secondary settling Tank
431 10 alonwith suitable sludge removal arrangement either by pumps or air lifting pumps Job 2

Supply, installation, testing & commissioning of Chlorine dosing system comprising of 100 ltrs
432 11 HDPE/FRP tank with 0-5 lph electronic metering type pump. Set 2

Supplying, installing, testing & commissioning of centrifugal filter feed water pumps SS
body, SS Impeller with mechanical seal along with motor. Pressure gauge with isolation cock,
NRV, Isolation valve on delivery line. Isolation valve, stainer at suction. The pump shall be
433 12 suitable for 415 ±10% volts, 3 phase, 50 cycles AC supply
Capacity : 10-12.0 m3/hr.
Head : 30 M
No. of Pumps (1 working + 1 standby) Set 2

Operation of pump shall be based on level controller proposed to be installed in tank as per
site location. The contractor to ascertain the Head required for pumps as per site conditions
Note: and provide accordingly.

Supplying, installing, testing and commissioning of MS vessel filter with frontal piping and
associated valves and accessories. Filter shall be suitable for minimum working pressure
434 13 of 5 kg / cm2 and shall include media, standard fittings like pressure.
13.1 Multigrade pressure sand filter media
Flow rate : 12.0 m3/hr
Filteration velocity : 15 m3/hr/m2
Filter Diameter : 1000 mm. Set 2

13.2 Activated Carbon Filter


Flow Rate : 12.0 cum/hr
Filteration velocity : 12 cum/hr/sqm
Filter Diameter : 1200 mm Set 2
Contractor may be asked to alter the number of filters and pumps subject to any revision to
Note : meet the desired capacities.

Page-250 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

Approval from pollution board at initial & various other stages of works including preparation
of report / drawings as per pollution board requirement, arrangement of raw sewage for
testing & commissioning. Contractor shall include the cost of all chemicals (consumed during
testing & commissioning and the cost of such items of works which are not explicitly
mentioned above, but are mendatory to have pollution board approval. Nothing extra shall be
435 14 payable in this regard. Job 1

Supply, installation, testing & commissioning of water softening plant (MS) for making up of
water for cooling tower comprising of multiport valve with brine ejection and plastic piping
complete with brine tank with fitting & brine fitting filtering media and complete charge of
436 15 cation exchange resine as given below

Water Flow : 10.0 m3/hr for 10 hr.


(Incomming Hardness 300mg/lit (Approx))
Working Pressure 3.0 Kg/Cum
Outgoing hardness less than 50 ppm
Water Softening plant as described above Set 2

Supply, installation, testing and commissioning of Filter Press of plate size 24"x 24" x 24 nos
plate with screw feed pumps for required capacity (1 working+1 standby), with
437 16 interconnecting piping and poly dosing system all complete. Set 1

Supply, installation, testing & commissioning of centrifugal horizontal / vertical irrigation


water supply pumps with SS Body, SS Impeller with mechanical seal along with motor.
Pressure gauge with isolation cock, NRV, Isolation valve on delivery line. Isolation valve,
stainer at suction. The pump shall be suitable for 415± 10% volts, 3 phase, 50 cycles a/c
438 17 supply
Capacity : 25 m3/hr.
Head : 45 M
No. of Pumps (2 working + 1 standby) Set 1

Supply, installation, testing & commissioning of centrifugal horizontal/vertical soft water


booster pumps for cooling towers of with SS Body, SS Impeller with mechanical seal along
with motor. Pressure gauge with isolation cock, NRV, Isolation valve on delivery line. Isolation
valve, stainer at suction. The pump shall be suitable for 415 ±10% volts, 3 phase, 50 cycles
439 18 A/C supply required.

Page-251 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

Capacity : 10 m3/hr.
Head : 30 M
No. of Pumps (1 working + 1 standby) Set 1

3 ELECTRICAL INSTALLATION FOR STP

Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of


motor control centre fabricated out of 14 gauge CRCA sheet steel. Cable gland plates shall
be provided on top as well as at the bottom of the panels. Panels shall be treated with all
anticorrosive process before painting as per specifications with 2 coats of red oxide primer
and final approved shade of powder coated paint. 2 Nos. earthing terminals shall be provided
for 3 phase, 4 wire, 50 Hz supply system. Lifting hooks shall also be provided in case of large
panels. Approval shall be taken for each panel before fabrication. Quoted rates shall be
inclusive of cables (in accordance to specification) with earthing from panel to each
440 19 motor/equipment.
Motor Control Centre
Incoming
200 amps TPN MCCB with the following accessories:
a. 0-500 volts 96 x 96 mm square electronic voltmeter with selector switch shall be protected
by 2 amps TP MCB. 1 Set
b. 0-100 amps 96 x 96 mm square electronic ammeter with selector switch and 100./5 amps
10 VA CL:1 CTs. 1 Set

c. Phase indicating lamps shall be protected by 2 amp SP MCB 3 Sets


Bus Bar

300 amps TPN (15 KA) copper bus bar with heat shrinkable insulation sleeves.

a. Required Nos of required capacity TPN MCB for direct on line starter/star delta starters
and out going feeders to all the pumps/blowers etc. (including standbies). Each compartment
shall contain auto / manual selector switch and indicating lamp with MCB’s for
‘ON/OFF/TRIP’ status of motor
b. Spare MCB’s of following capacities:
i. 32 amps TPN MCB’s 3 Nos.

c. Necessary cable alleys, internal / cabling, wiring, cabling from MCC to various pumps /
equipment and interlocking, earthing for all equipment shall also included
a. All MCCBs / MCBs shall be of 15 KA breaking capacity and suitable for motor duty
Notes : application.
b. All motor starters shall be provided with Automatic level controller

Page-252 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

c. DOL starters shall be used for mototrs below 10HP and Star-Delta Starters for other
motors .

d. Provision shall be made for providing potential free contacts to all pumps starters
MCC for all STP equipments/pumps as described in sub head II Job 1

Total Price of Section E

SECTION F- AUDIO VISUAL SYSTEM


A) AUDIO VISUAL EQUIPMENTS

Supply, installation, testing & Commissioning of 3 Chip DLP Projector, Resolution (Native /
Max) , WUXGA (1920 x 1200) , Display Type 0.67" DLP x 3 , Aspect Ratio 16:10 (Native)
,Brightness 6000 ANSI Lumens , Contrast Ratio 2000:1 , ,Connectivity Inputs 1 x HDMI/DVI ,
1 x Composite , 1 x S-Video , 1 x RGB D-Sub 15pin ,Control 1 x RS-232, Lens Shift Vertical:
+/- 100% ,Horizontal: +/- 30% ,Brightness Uniformity 95% , complete as per the
specifications, complete with hardware for mounting in ceiling including all accessories
required for mounting as required. [Approved Make : Barco / Christie/ Digital Projection]

441 1 each 2

Supply, installation,testing & Commissioning of Zoom Lens with throw ratio of 2.0 - 4.0 :1 ,
Powered Zoom / Focussing complete as per the specifications, complete as required.
442 2 [ Approved Make : Barco / Christie / Digital Projection] each 2

Supply,installation,testing & Commissioning of 3 Chip DLP Projector, Resolution (Native /


Max) , WUXGA (1920 x 1200) , Display Type 0.67" DLP x 3 , Aspect Ratio 16:10 (Native)
,Brightness 12000 ANSI Lumens , Contrast Ratio 1700:1 , ,Connectivity Inputs 1 x HDMI/DVI
,1 x Composite , 1 x S-Video , 1 x RGB D-Sub 15pin ,Control 1 x RS-232, ,Lens Shift Vertical:
+/- 100% ,Horizontal: +/- 30% ,Brightness Uniformity 95% , complete as per the
specifications, complete with hardware for mounting in ceiling including all accessories
required for mounting as required. [Approved Make : Barco/ Christie/ Digital Projection ]

443 3 each 1

Page-253 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

Supply,installation,testing & commissioning of Zoom Lens with throw ratio of 4.0 - 6.0 :1 ,
Powered Zoom / Focussing complete as per the specifications, complete as required.
444 4 [ Approved Make : Barco / Christie / Digital Projection] each 1

Supply, installation, testing & commisioning of wall/ ceiling mounted Matte white motorized
projection screen with tubular ( Non lubricant motor, 3 steps control position, LVC interface
for control) including required suspenders, brackets complete as required at site matt white
finish view area. Fabric shall be flame retardent and mildew resistant, remote controlled
operation of the screen, parallel touch panel control. A straight rigid tubular metal header
more than 75mm in diameter with black masking 450mm at top and 900mm at bottom.
445 5 Approved Make- Draper/ Dallite/ Harkness.
a) 8850mm X 5500 mm (H) each 1
b) 4480 mm X 2800 mm (H) each 2

Supply, installation, testing & commisioning of Architectural/ Video Interface Panel. Table top
architectural panel with pneumatic mechanism. Compatible to current computer video
sources of vrying resolution. RGBS,
RGsB, HDTV, component video, S-video and composite video signals. Video and Audio
output-5 Female BNC fir RGBHV/ 15 Pin HD & 3.5 mm mini connector. 300 MHz video
bandwidth. RS 232 control, Horizontal Shift control. Floor mount/ wall mount as required at
site. Accessories like floor junction box included in the scope of work.
Approved Make- Extorn HAS 400 + Extender AAP/ Altinex-
446 6 TNP121 or equvalent as approved. each 3

Supply, installation, testing & commissioning of Video Data Switcher cum scaler with 2
composite video , 2 S-video ,1 component video (interlaced, progressive, or HDTV) , 2
RGBHV, RGBS, RGsB ,1 DVI-D digital video (single link) Inputs , Resolution range 640 x
480 to 1920 x 1200, 480p, 576p, 720p, 1080i, and 1080p ,Scaled Output Resolution upto
1920 x 1080 , complete with 19'' rack mounted as per the specifications, complete as
447 7 required.[Approved Make : Extron - IN 1508 / Kramer - VP 729 ] each 3

Page-254 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

Supply,installation, testing & commissioning of Touch Control System with 8.4” WiFi
Touchpanel , 800 x 600 resolution , 16-bit Isys i/O graphics , Synapse image rendering
algorithm ,802.11a/b/g Wi-Fi 2-way wireless communications , with Ethernet Processor &
required IR Probes to control the Audio Visual system . [Approved Make : Crestron - TPMC
448 8 8X / AMX - 8.4 Modero View Point] each 3

Professional grade DVD Player- Supply, installation, testing & commissioning of Professional
grade rack mounting DVD player compatiable for play back of DVD audio CD and Video CD
formats, including CR, CD-RW MP3 etc; dual discrete optical lasers with MPEG 2 decoding
and 32 bit processor, video resolution>500 TV lines, Audio frequency response within 0.5dB
from 2Hz to 40000Hz. Signal to noise ratio better than 110dB, composite video and S-video
outputs 1V p-p, 75 ohms, Audio outputs 1 V rms, 6 channel for Dolby Digital and LR streo
outputs, Video output RGBHV (through built in or external converter.) Approved Make-
449 9 Denon DNV 100/ Tascam DV-D6500/ Harmon Kardon 31. each 3

Supply , installation , testing & commissioning of Interactive Electronic Board with over all
size of 7'8'' X 2'9'' (100" diagonal) with software and Set of pens , Including short throw
projections system with bracket for mounting complete in all respects , complete as
450 10 required . [Approved Make :Team Board / Smart Board / E-Learn/ QDMA ] each 2

Supply, installation, testing & commissioning of Communication Camera with 1/4" CCD with
340,000 effective pixels , Pan/Tilt/Zoom camera with 9 preset positions ,26x Optical Zoom
with powered telephoto lens , Built-in Infrared illuminator ,Cascade control facility for up to 9
cameras Composite BNC (RCA with included BNC/RCA connector),S-video (with included
VC-EX3 adapter) Pan Angle Range ±100° (Standard) / ±170° (Reverse) , Tilt Angle Range
+90°/-30° (Standard) / +10°/-90° (Reverse) , TV Lines 420 , SNR 48 dB , Horizontal Field-of-
View 3 to 47.5 degrees (65 degrees with wide angle lens adapter) , White Balance Auto
,Exposure Auto/Manual ,Focus Auto/Manual ,Focus Length 3.5 to 91mm, f/1.6 to 4.0 , Pan
Speed 1 to 90 degrees/sec .,Tilt Speed 1 to 70 degrees/sec ,Control RS232 serial as per the
specifications, complete as required.[Approved Make : Canon / Panasonic / Elmo.]
451 11 each 3

Page-255 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

Supply,installation,testing & commissioning of Video Conferencing System HD ( Upto 4


sites ) with BANDWIDTH H.320 up to 384 kbps , H.323 up to 1.1 Mbps ,SIP up to 1.1
Mbps ,VIDEO STANDARDS H.261, H.263, H.263+, H.263++ (Natural Video), H.264 , H.261,
H.263, H.263+, H.263++ (Natural Video), H.264 , IP NETWORK FEATURES - IEEE
802.1x/EAP Network Authentication ,H.235 Gatekeeper as per the specifications, complete
452 12 as required. [Approved Make : Polycom / Tandberg / Lifesize ] each 3

Supply & drawing of single conductor 20AWG Non plenum Video Cable, in the conduit /
453 13 raceway etc. complete as required.[ Approved Make : Extron / Kramer / Belden.] metre 400

Supply & drawing of two conductor 26AWG Non Plenum S-Video Cable, in the conduit /
454 14 raceway etc. complete as required.[ Approved Make : Extron / Kramer / Belden.] metre 350

Supply & drawing of RGBHV Cable, in the conduit / raceway etc. complete as required.
455 15 [ Approved Make : Extron / Kramer / Belden.] metre 500

B) SOUND REINFORCEMENT SYSTEM


SUBHEAD - I MICROPHONES- WIRELESS AND WIRED

Supply, installation, testing and commissioning of Wireless microphone system handheld with
transmitter and rack mount receiver unit UHF frequency range, Dynamic cordiod polar pattern
microphone signal to noise ratio> 60dB, frequency response 100 Hz to 17000Hz, true
diversity antena, complete with adapter, batteries and rack mount kit for the receiver.
456 1 Approved Make- Shure SLX(SM58)/ AKG WMS450 (D-5)/ Sonheisser. each 4

Supply, installation, testing and commissioning of wireless microphone system- Lavalier


microphone with transmitter and 19'' rack mountable receiver UHF frequency range, omni-
directional polar pattern microphone, signal to noise ratio> 60dB, frequency response 100Hz
to 17000Hz. True diversity antenna complte with antenna distribution system, complete with
adapter, batteries and rack mount kit for the receiver. Approved
457 2 Make- Shure SLX (WL-93)/ AKG WMS 4500(CK 77)/ Sonheisser. each 4

Page-256 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

Supply, installation, testing & commissioning of Power & Antenna Distribution system for
wireless microphones complete as required to allow four diversity receivers to use the same
pair of antenna, rack mountable with inbuilt power distribution, RF signal amplifier, Active
wideband type suitable for UHF frequencies for the above receivers and as per technical
specifications enclosed. Approved Make- Shure UA 844/ AKG PS 4000+ Accessories/
458 3 Sonheisser. each 2

Supply, inatllation, testing & commissioning of Condenser cardioid microphone, Lectern/


Podium for speech, Transducer type: Condenser, Directional characteristics: Cardiod,
Frequency response 100 Hz to 17000Hz, free field sensitivity at 1KHz re: 1V/ microbar:-
52.5dB, output impedence rated at 150ohms, Maximum sound pressure level (1KHz at 1%
THD) 122dB, flexible metallic stem ,minimum 450mm long, connector: 3 pin standard XLR at
end of stem, complete with 6m long cable, mounting hardware for fixing on lecturn/ podium.
459 4 Approved Make: Shure MX 418/C or AKG GN99 H/L. each 1

Supply, installation, testing and commissioning of Dynamic Cardiold Vocal microphone,


handheld complete handheld microphone for leads vocal, Dynamic cardiod polar pattern,
sensityvity 2.5mV/Pa, Frequency response 100 Hz to 17000 Hz, Load Impedence > 150F,
460 5 XLR socket for mounting. Approved Make: Shure SM 58/ AKG D-5. each 6

Supply, installation, testing and commissioning of Wireless microphone system- WHS 450
Vocal Set/C5 (with C5 Mic) including 1X HT450/C handheld with transmitter 1X mic holder
and rack mount receiver unit complete as required. Approved Make: AKG WMS
461 6 450/SHRUE each 4

Supply, installtion, testing and commissioning of Wireless microphone system- WHS 450
presenter set, including 1 X SR450 receiver, 1X PT450 pocket transmitter, 1 X C407L lavalier
wireless microphone with body pack and rack mount receiver unit complete as required
avaliable in following frequency bands and included AC adapters.
462 7 Approved Make: AKG WMS 450/ SHURE each 4

Page-257 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

Supply, installtion, testing and commissioning of Semi-open, circum-aural dynamic stereo


headphone, mini XLR - connector. Approved Make:
463 8 AKG K 240/ SHURE each 2

Supply, installtion, testing and commissioning of Condencer cordiod Microphone with flexible
stem minimum 450mm long lectern/ podium speech goose neck module, XLR connector.
464 9 Approved Make: AKG GN 155+ CK 33/ SHURE each 2

Supply, installtion, testing and commissioning of soundcraft 16 channel mixer with 4 inputs
and 8 outputs complete as required. Approved Make: Sountcraft LX 7ii 16
465 10 ch/ SHURE/ Allen & Heath. each 2

Supply, installation, testing and commissioning of 2X6 Loudspeaker Management systems/


466 11 display. Approved Make: Dbx 260. each 2

Supply, installtion, testing and commissioning of 15'' Two way self powered speaker system,
400 watt LF and 100 watt HF crown class D Amplifiers. DSP featured Input section with
467 12 selectable EQ.15'' Differential Drive woofers. Approved make: JBL PRX 515/ EAW. each 4

SUBHEAD - II REVERB SIGNAL PROCESSOR

Supply, installation, testing & commissioning of Dual channel reverb processor Analouge
Audio Inputs, connectors two 1/4'' TRS balanced or unbalanced, Impedence :20kohms
balanced, 10kohms unbalanced . Approved Make: LEXICON MX 200/dbx/ alesis/
468 1 Equivalent. each 1

Supply, installation, testing and commissioning of Digital Signal Processor network with 4
anlouge & AES/ EBU inputs and 8 analouge & AES/EBU outputs 24 bit A to D and Dto A
coverters, Frequency response 100Hz to 17000Hz, THD < 0.01% (line level), Signal Matrix
Mixer, Automatic feedback suppressor, Graphic/ parametric equilization for each channel,
Digital time delay facility of up to 2 sec. Full function compressor / limiter, phase adjustment
and invert facility, front panel functions and display with security lockout, serial port for
programming. Approved Make:
469 2 DBX4800 Drive Rack/ Biamp Nexia. each 1

SUBHEAD - III POWER AMPLIFIER

Page-258 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

Supply, installation, testing and commissioning of Dual Channel Power Amplifier with
3500Watt per channel at 4 ohm operation, frequency response 20Hz to 20000Hz, Damping
Factor> 5000, siganl to noise ratio> 105dB, Total harmonic distortion<0.1% at 20Hz to 20KHz
protection, full short circuit, open circuit & thermal. Approved Make: Crown MAi 9000/ Crest
470 1 Audio/ QSC each 1

Supply,installation, testing and commissioning of Dual channel power Amplifier with >= 2500
Watt per channel at 4 ohm operation, frequency response 20Hz to 20000Hz, Damping
Factor>5000, signal to noise ratio>105dB, total harmonic distortion <0.1% at 20Hz to 20KHz,
Protection- Full short circuit, open circuit & thermal.
471 2 Approved Make: Crown MAi 5000/ Crest Audio/ QSC each 3

Supply, installation, testing and commissioning of Dual Channel Power Amplifier with >= 800
Watt per channel at 4 ohm operation, frequency response 20Hz to 20000Hz, Damping
Factor>5000, signal to noise ratio>105dB, total harmonic distortion <0.1% at 20Hz to 20KHz,
Protection- Full short circuit, open circuit & thermal.
472 3 Approved Make: Crown XTi 2000/ Crest Audio/ QSC each 1

Supply, installation, testing and commissioning of Dual Channel Power Amplifier with >=
1200 Watt per channel at 4 ohm operation, frequency response 20Hz to 20000Hz, Damping
Factor>5000, signal to noise ratio>105dB, total harmonic distortion <0.1% at 20Hz to 20KHz,
Protection- Full short circuit, open circuit & thermal.
473 4 Approved Make: Crown XTi 4000/ Crest Audio/ QSC each 3

SUBHEAD - IV FULL RANGE LOUDSPEAKER SYSTEM

Supply, installation, testing & commissioning of Main Loudspeaker assembly- Full range two
way speaker system, with passive amplifier operation, frequency response 20Hz to
20000KHz, construction: 1X 15'' LF Driver, 3X1.5'' High frequency exit compression Driver
with Horn, Power Capacity: diffrential drive LF 800W, Nominal impedence: 8 ohms, sensitivity
(1W, 1m):95dB SPL, Nominal dispersion:100o H X 15o V, HF on constant curvature wave
guide. Dual angle pole socket and in ringing Hardware.
474 1 Approved Make: JBL VRX 932 LA/EAW each 8

Page-259 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

Supply, installation, testing & commissioning of wall/ floor mount subwoofer, 18'' bass reflex
subwoofer, Frequency response 20Hz to 20000KHz, Construction :18'' LF differential drive
woofer, Power Capacity 800W/1600W/ 3200W, Nominal impedence: 8 ohms, sensitivity (1W,
475 2 1m):95dB SPL. Approved Make: JBL VRX 918S/ EAW. each 4

Supply, installation, testing and commissioning of Array frame for suspending up to


6VRX932LA, enclousure includes 4 X Quick release pin, 2 X shakleless, 2 X drop levers.
476 3 Approved Make: JBL VRX-AF each 2

Supply, installation, testing & commissioning of Front Fill loudspeaker- 8'' Full range
loudspeaker system comprising of 8''LF and 1'' HF compression low-mid drivers and a horn
loaded HF driver with integral crossover and low profile for front fill. The height of the speaker
should not exceed 550mm, due to avlibility of the space under the stage. Frequency
response 40Hz to 18000Hz, power handling:150W pink, sensitivity (1W, 1m):90dB SPL.
Nominal coverage: 110o X 85o. Approved Make: JBL29 AV
477 4 Control/ EAW UB22Z each 3

Supply, installation, testing and commissioning of Green Room Speaker- Full range two way
speaker system. Monitoring loudspeaker in sealed baffle, suitable for wall mounting,
frequency response 100Hz to 17000Hz, construction5-1/4'' LF Driver, 3/4'' HF driver, Power
handling 150W rms, 30Watt LMT, complete with LMT and wall bracket.
478 5 Approved Make: JBL25T Control/EAWUB12 each 2

Supply, installation, testing and commissioning of Control room speaker - Full range two way
speaker 10'' two way powered speaker system, Frequency response 90Hz to 16000Hz,
Construction 10'' LF Driver, 1'' HF Driver, Power Handling 125W rms, 50Watt HF, complete
479 6 with LMT and wall bracket. Approved Make: JBLEON10G2/EAW each 1

Page-260 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

Supply, installation, testing and commissioning of Effect/ Fold back speaker - Two way full
range active stage moniter speaker system. 12'' two way speaker system, Frequency
response 100Hz to 20000Hz. Construction: 12'' LF Driver, 1.5'' High Frequency, Power
Capacity: LF 350W, HF 100W (continuous/ Long Term), Max SPL 94dB@(1W, 1m). Nominal
480 7 dispersion: 70o H X 70o V. Approved Make: JBL MRX512/EAW each 4

Supply, installation, testing and commissioning of Ceiling speakers- 6-1/2'' LF and 3/4''
titanium coated HF frequency response 100Hz to 20KHz, Power capacity 150W, sensitivity
1W, 1m 89dB, Nominal coverage 110o conical complete with ceiling brackets trim rings etc.
481 8 Approved Make: JBL Control 26CT each 6

SUBHEAD - V AUDIO MIXER & CD/ CASSATTE RECORDER

Supply, installation, testing and commissioning of Audio Mixer 32 Channel-32 mono


microphones/ line inputs, 04 group outputs, Stereo and Mono output, Auxiliary inputs >
4(Balanced) and outputs >2 (Balanced), Frequency response 100Hz to 17000Hz, Total
Harmonic distortion should be<= 0.1%, Equivalent Input noise should be -128dBu, Cross
talks at least -70dB between input channel and also input and output channel, Phantom
power +48V DC, Streo Input Level (max) should be +20dBu, Headphone monitoring socket
complete with AKG 55 Monitoring Headphone.
482 1 Approved Make: Soundcraft GB4 32/ Yamaha each 1

Supply, installation, testing and commissioning of Professional CD/ Cassete recorder combi
Deck RS 232 Control, Pitch Control +/- 12% in 0.1 steps, CD/ Cassete Recorder, CD/ CDRW,
MP-3 player. Approved make: DENON DN-T 625/
483 2 TASCAM each 1

SUBHEAD - VI ACCESSORIES, EQUIPMENT RACK ETC.

Supply, installation, testing and commissioning of Control equipment rack for audio and video
equipment. 19'' floor standing amplifier rack, suitable for all the control equipment for SRS
and AV system with provision for additional 3U blank plate for adding an equipment at a later
date, there shall be provision of at least 1U blank plate spacing between two adjacent
equipment so as to provide sufficient ventilation. Approved Make:
484 1 President/ Rittal each 3

Page-261 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

Supply, installation, testing and commissioning of Patch panel for input/ output circuit each
with 48(2 rows of 24) tip, ring and sleeve jack and 12 Nos. of 450mm long patch cords, rack
mountable with lacing brackets, solder tag connections on rear.Approved Make: Neutrik/
485 2 Switchcraft. each 3

Supply, installation, testing and commissioning of Microphone connector-F-XLR panel mount


486 3 connect. Approved Make: Neutrik/ Switchcraft. each 53

Supply, installation, testing and commissining of Loudspeaker connector- Speak On Female


487 4 panel mount connector. Approved Make: Neutrik/ Switchcraft. each 8

Supply, installation, testing and commissioning of Microphone stand- Floor stand boom type,
powder coated or chrome plated, with heavy base for maximum stability, incorporating shock
488 5 mounting. Approved Make: Ahuja/ AKG. each 6

Supply, installtion, testing and commissioning of Microphone stand- Desk type stands,
powder coated or chrome plated, incorporating shock mounting. Approved Make: Ahuja/
489 6 AKG. each 6

Supply, installation, testing and commissioning of wall/ floor mount junction boxes two way,
construction:16SWG galvanized / powder coated MS sheet, 200mm X 150mm X 150mm,
490 7 wall or floor mount with hinged lids. each 33

Supply, installation, testing and commissioning of Wall/ floor mount junction boxes two way
construction: 16 SWG galvanized/ powder coated MS sheet, 75mm X 150mm X 150mm wall
491 8 or floor mount with hinged lids. each 18

SUBHEAD - VII CABLING AND CONDUITING


Supplying, drawing, testing and commissioning of Microphone cable- 23/.2mm twin twisted
shielded, ATC complete. Approved Make: Belden/ Sommer/ Gotham/
492 1 Delton./ Klotz. metre 1 200

Page-262 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

Supplying, drawing, testing and commissioning of Main Loudspeaker cable for speaker- twin
twisted, two core 2.5 Sqmm Multi- strand typically140 stands of copper 0.15mm dia each,
conductor resistance <4.5 ohm, overall PVC sheath. Approved make: Belden/ Sommer/
493 2 Gotham/ Klotz. metre 950

Supplying, drawing, testing and commissioning of 3core 2.5sqmm main cable.


Approved Make: Belden/ Sommer/ Gotham/
494 3 Delton./Finolex metre 700

Supply, installtion, testing and commisssioning of Loudspeaker cable: Twin twisted two core
495 4 80/.2mm complete. Approved Make: Beldon/ Sommer/ Gotham/ Delton. metre 400

Fabricating and installing following sizes of perforated M.S. cable trays including horizontal
and vertical bends, reducers, tees, cross members and other accessories as required and
duly suspended from the ceiling with M.S. suspenders or fixing on surface and including
painting with powder coating etc. as required. Approved Make:Pilco/ slotco/ Rico steel/
system
steel/ murphy.
496 5
a) 150mm width X 50mm depth X 1.6mm thickness metre 200

SUBHEAD - VIII EARTHING

Earthing with copper earth plate 600mm X 600mm X 3mm thick including accessories and
providing masonary enclosure with cover plate having locking arrangement and watering pipe
497 1 etc.(but without charcoal or coke and salt) as required. each 1

498 2 Extra for using salt and charcoal for G.I. or copper plate earth electrode as required. each 1
Providing and fixing 25mm X 5mm copper strip in 40mm dia G.I.pipe from earth electrode as
499 3 required metre 10
Providing and fixing 25mm X 5mm copper strip on surface or in recess for connections etc.
500 4 as required. metre 50
Providing and fixing 4mm dia copper wire on surface or in recess for loop earthing as
501 5 required. metre 50
Supplying and drawing 2.24mm dia Copper conductor wire loop earthing in the existing
surface/ recessed steel/ PVC conduit/ PVC casing and capping / wood batten along with
502 6 other wires as required. metre 200
Providing and fixing earth bus of 50mm X 5mm copper strip on strip on connections etc. as
503 7 required. metre 1

Page-263 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

Total Price of Section F

SECTION-G - HVAC Work

(A) Centrifugal Chillers


1 WATER CHILLING UNITS

SITC & Handling over Centrifugal type Imported flooded water chilling units of specified
capacity, getting ARI certification at specified conditions, R-134a gas, Full Load acceptance
testing and running in testing, all as per specification, date sheets drawings and as required.
The chiller shall be provided with VFD drive. Chillers shalll be suitable for 415 V, + 10%, 50
504 cycles + 3% 3phase 4 wire supply.
# Type Chilling Unit - Centrifugal
# Compressor - Hermetic / Semi-hermetic / Open
# Compressor - 1 per machine
# TR output-500 TR at specified condition
# Refrigerant - R-134a precharged in factory
# EWT Chiller - 12.770 C (550 F)
# LWT Chiller - 6.660 C (440 F)
# Chiller fouling factor -0.0005 (British Units)
# Condenser EWT - (90 F) / 97.5 F LWT
# Condenser fouling factor-0.001 (British Units)

# IKW / TR at full load at above condition - not more than 0.68 at specified condition
# Chiller Flow rate 1090 usgpm
# Condenser flow rate - 1910 usgpm
Chiller with VFD Drive each 3

Total Of Chiller S/I/T/C including all taxes duties and levies as applicable.

(B) ALL AIR SIDE EQUIPMENT


1 Double Skinned Floor Mounted / Ceiling Suspended Air Handling Units

Page-264 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

Supplying, installing, testing and commissioning of factory built Air Handling units double skin
type with 25mm thick panels consisting of Stainless Stal casing of thickness 0.8mm outside
layer and 0.8mm inside layer with zinc coating and polyurethene foam (PUF) insulation
having density of 42 kg/cum complete forward / backward curved supply air centrifugal fan
which shall be plug type (SWSI) direct driven with VFD suitable for static pressure etc. as
detailed below, chilled water cooling coil with aluminium finned copper tubes (tube thickness
not less than 0.5mm), filter section having minimum 10 micron particle size with an efficiency
of 90% filters, heat recovering wheels for cooling the fresh air, TEFC motor suitable for 415 +
10% volts, 50 Hz, 3 phase AC supply, drain connection with stainless steel drain pan duly
insulated and necessary vibration isolation arrangement to avoid any vibration etc. complete
as per specifications and drawings.

505
The face velocity across cooling coil shall be limited to 152 MPM maxm.The capacity of
Air-handlers shall be as follows:
AHU NO. Capacity in cfm Approx. TR
i SAF G/F 1 5500 10 each 1
ii SAF F/F 2 17800 40 each 1
iii SAF F/F 3 17800 40 each 1
iv SAF S/F 4 17800 40 each 1
v SAF S/F 5 17800 40 each 1
vi SAF T/F 6 19200 45 each 1
vii SAF T/F 7 19200 45 each 1
(The following provisions shall be deemed to be included in the main item).

a Variable frequency drive with bypass arrangement with VFD units.


b Lamp switch.
c Fire retardant flexible joints for outlets of the units.
d Sound attenuation section for low noise.
e Provision for electrically interlocked fan section with access door.

2 SITC & Handling over of factory built floor mounted vertical / horizontal chilled water double
skin type Air Handling Units made of 25mm insulated panels consisting of Stainless Stail
casing of 0.8mm outside and inside layer with factory applied PUF insulation (By injecting
with the help of injection moulding machine) complete with fan section with forward /
backward curved fan, chilled water coil section filter section strip heaters, heating
thermostats, safetystat etc. as per Data sheets, specifications and drawing and as required,
filter - 90% efficency up to 10 micron with VFD Drive.

506
AHU NO. Capacity in cfm Approx. TR

Page-265 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

i PRB G/F 8 4000 each 1


ii PRB G/F 9 7000 each 1
iii THSTI G/F 10 16000 30 each 1
iv THSTI G/F 11 14500 25 each 1
v THSTI G/F 12 28000 50 each 1
vi THSTI G/F 13 28000 50 each 1
vii THSTI F/F 14 28000 45 each 1
viii THSTI F/F 15 28000 45 each 1
ix THSTI S/F 16 28000 45 each 1
x THSTI S/F 17 28000 45 each 1
xi THSTI T/F 18 14500 30 each 1
xii THSTI T/F 19 12000 20 each 1
xiii LIB. G/F 20 11000 30 each 1
xiv LIB. G/F 21 11000 30 each 1
xv LIB. F/F 22 15000 30 each 1
xvi LIB. F/F 23 15000 30 each 1
xvii LIB. F/F 24 15000 30 each 1
xviii LIB. F/F 25 15000 30 each 1
xix RCB G/F 26 13000 30 each 1
xx RCB G/F 27 17500 35 each 1
xxi RCB G/F 28 17500 35 each 1
xxii RCB G/F 29 25000 40 each 1
xxiii RCB F/F 30 17500 35 each 1
xxiv RCB F/F 31 25000 40 each 1
xxv RCB S/F 32 17500 35 each 1
xxvi RCB S/F 33 25000 40 each 1
xxvii RCB T/F 34 18500 35 each 1
xxviii RCB T/F 35 11500 20 each 1

3 SITC & Handing over of ceiling suspended fan coil units complete with double skin insulated
with 25mm PUF cabinet, copper tube aluminium finned cooling coil, three speed motor,
filters, forward curved low noise fan, double insulated drain pain, stripheater for winter
heating, heating / cooling thermostat, regulator for fan speed control, wiring from wall plate to
the fan motor and strip heaters etc. complete as per specifications and as required.

507
i 800 cfm with 2 kw strip heater each 2
ii 1000 cfm with 2 kw strip heater each 26
iii 1200 cfm with 2 kw strip heater each 34

(C) PUMPS

Page-266 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

1 SITC of vertical split case, back pull out type, End suction pump complete with ISMC 125, MS
Channel iron base, Hot dipped galvanised for anti-corrosion, stainless steel hold down bolts
and nuts, tyre type / Lovejoy coupling, TEFC Eff-1 motors, SS coupling guard, brass purge
valves.
508
a CDW Pump Flow - 1910 usgpm / 80 Ft head / 1450 rpm each 3
b Primary CHW Pump Flow - 1090 usgpm / 40 Ft head / 1450 rpm each 3
c Secondary CHW Pump Flow - 1090 usgpm / 80 Ft head / 1450 rpm
each 3

(D) COOLING TOWER


1 SITC of 'Induced draft' cross flow or counterflow, FRP casing, rectangular, FRP integrated
basin (without bolted bottom plate), without rotating sprinkler, PVC fill, PVC eliminator, FRP
adjustable multi-blades fan of cast aluminium alloy, stainless steel hardware, hot water basin
and hot water header, suction sump SS strainer, brass float valve, HDG or extruded
aluminium ladder, TEFC weather proof motor with FRP cover / guard.
Tower Rating (Each Tower) 600 TR
Flow Rate 1910 usgpm (each)
Hot Water 97.50 F
Cold Water 900 F
Wet Bulb Temp. 830 F
(Tower location on the roof of service block/AC plant) Fan Motor Rating 37.5 KW

509 each 3

(E) CONDENSER WATER PIPING


1 SITC of cast iron heavy duty pot strainer of PN-16 rating (one at each cooling tower outlet)
with SS-304 double mesh strainer, dimension of strainer basket minimum 350mm Ø and
500mm height, complete with galvanised nuts and bolts, gaskets, 50 dia butterfly valve for
drain as per specifications and as required.
Flow Rate = 1910 usgpm
Pipe = 300 mm Ø
510 each 3

2 SITC of MS heavy class black pipes for condenser water piping, complete with elbows,
flanges, specials, other fittings and steel supports. All fasteners will be galvanised. Main
header size for 3 x 1910 usgpm as per specifications and as required.
511
a 450 mm Ø (24" Ø) mtr 90
b 300 mm Ø (12" Ø) mtr 120

Page-267 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

3 SITC of Valves (Complete with fittings, Nuts, Bolts & Gaskets (PN-16 Rating).
512
a 300 mm Ø Butterfly Valve each 26
b 50 mm Ø Butterfly Valve each 6

c SITC of C.I. Check Valve double plate type (PN-16) rating, as per specification 300 mm Ø
each
513 3

514 5 SITC of cast steel ball valves (PN-16 Rating) (20 mm Ø). each 12

515 6 SITC of cast steel ball valves (PN-16 Rating) (25 mm Ø). each 6

7 SITC of water pressure gauge (100 mm Ø) bourdon type with brass ball valve of 3/8" Ø and
SS tubing, socket. Range (0-50) / (0-100) as required. each
516 12

8 SITC of Mercury in glass industrial thermometer in SS-304 casing with 0.5 C least count,
range 0-50 C. Brass oil filled thermowell of 1/2" size. each
517 6

(F) CHILLED WATER PIPING


1 SITC of factory pre-insutated 'C" class (heavy duty) M.S. chilled water pipeing with factory
insulation/ jacketing (HDPE/Al/GI) for buried/ indoor application with all necessary fithing like
bands tees, reducers, flanges, joints, sports, excavation, refilling etc. (As per approved
drawings & Specifications enclosed) Main chilled water header to be sized for 3 x 1010
USGPM.

518
a 350 mm Ø Piping mtr 500
c 250 mm Ø Piping mtr 200
d 200 mm Ø Piping mtr 310
e 150 mm Ø Piping mtr 100
f 125 mm Ø Piping mtr 50
g 100 mm Ø Piping mtr 500
h 80 mm Ø Pining mtr 400
i 65 mm Ø Pining mtr 450
j 50 mm Ø Piping mtr 100
k 40 mm Ø Piping mtr 20
l 25 mm Ø Piping mtr 10

2 SITC of CI Butterfly valve (PN-16) (16KLg/cm2 rating) as per Specifications with insulaction
519 as required.

Page-268 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

a 250 mm Ø Butterfly Valve each 26


b 200 mm Ø Butterfly Valve each 4
c 150 mm Ø Butterfly Valve each 4
d 125 mm Ø Butterfly Valve each 8
e 100 mm Ø Butterfly Valve each 20
f 80 mm Ø Butterfly Valve each 10
g 65 mm Ø Butterfly Valve each 80
h 50 mm Ø Butterfly Valve each 20

3 SITC of Swing check valve,C.I double flap , as per specification, (PN-16 Rating) with
520 insulaction as required.
a 250 mm Ø each 8

4 SITC of CI Balancing valve as per specifications, Rating No.PN-16.and insultion as requred


521
a 350 mm Ø each 4
c 250 mm Ø each 4
d 200 mm Ø each 2
e 150 mm Ø each 2
f 100 mm Ø each 2
g 80 mm Ø each 2
h 65 mm Ø each 2
i 50 mm Ø each 2

5 SITC of CI Y-type strainer, PN-16 rating, as per specifications and insultion as requred.
522
a 250 mm Ø each 8

6 SITC of water pressure guage (100 mm Ø) bourdon type with brass ball valve of 3/8" Ø and
SS tubing, socket.
523 Range (0-50) / (0-100) as required. each 100

7 SITC of Mercury in glass industrial thermometer in SS-304 casing with 0.5C least count,
range 0-50 C. Brass oil filled thermowell of 1/2" size.
524 each 80

8 SITC of Sintex Make HDPE bare expansion tank of 1000 litres capacity complete with bottom
support of red sand stone, inlet outlet nozzles, valves, float valves, level indicator.
Note : Tank is roof mounted.
525 each 2

(G) DRAIN PIPING

Page-269 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

1
SITC of GI - B class drain piping, as per specifications, complete with threaded fittings,
couplings, flanges, unions, u-traps, as required. Welding is not to be done on GI pipes. All
526 pipes to be leak tested, prior to insulation. Quote bare piping.
a 80 mm Ø mtr 200
b 65 mm Ø mtr 200
c 50 mm Ø mtr 100
d 40 mm Ø mtr 100
e 25 mm Ø mtr 200

(H) DUCTING & ANCILLARIES


1 SITC of Factory fabricated GI sheet duct work complete with all accessories, steel supports,
connection pieces of AHUs and specials shall be fabricated neatly, as per IS-655 and
attached specifications. Ducting as per specifications IS-655.
527
a 24 G (0.6 mm) (0-750mm) sqm 8000
b 22 G (0.8 mm) (751-1500mm) sqm 2000
c 20 G (1.0 mm) (1501-2250mm) sqm 3000

2 SITC of Volume control dampers, GI Black Painted dampers for control of air in branch ducts,
sqm
528 low leakage type as per specifications. 10

3 SITC of Fire and smoke dampers, as per specifications with U/L stamped fusible link, spring
loaded.
Supplying, fixing, testing and commissioning of fire dampers in supply air duct / main branch
and return air path as & where required of required sizes including control wiring. The
damper shall be motorized and spring return so as to close the damper in the event of power
failure automatically and open the same in case of power being restored. THe spring return
action shall be built mechanism and not extremally mounted. The damper shall also be
closed in the event of a fire signal which shall also be closed in the event of a fire signal
which shall be provided by the deparmtent in AHU room etc as per specifications as required.

529
a Fire Damper sqm 40
b Actuator each 35

4 SITC of Power coated, extruded aluminium SA diffusers with GI VCD (Black Painted).
530 sqm 20

5 SITC of Power coated, extruded aluminium RA diffusers without VCD.


531 sqm 20

Page-270 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

532 6 SITC of SA grills with VCD as per specifications (Aluminium). sqm 20

533 7 SITC of RA grills with VCD as per specifications (Aluminium). sqm 20

534 8 SITC of Powder coated, extruded aluminium continuous grills. sqm 20

9 SITC of Powder coated extruded aluminium fresh air intake louvers complete with washable
10µ filters, GI bird screen & aluminium VCD. Intake velocity 400 fpm.
535 sqm 10

(I) INSULATION
1 SITC of Insulation of expansion tank with nitrile foam 9mm thick with pidilite adhesive and
polythene sheet, there after. Finally 24 G aluminium cladding. (1000 litres capacity Sintex
536 Tank). job 2

2 SITC of chemically cross linked clsoed cell polythelene (XLPE) fire retardent grade insulation
of desrsity not less than 30kg per cum, 13 mm thick in a singler with factory lamination of 30
micron aluminium foil, as per specifications as enclosed
537
# SA Duct 13 mm thick sqm 10000

538 3 Duct Accoustic Lining


SITC of Duct accoustic lining with 30 kg per cum denesityglass wool, 10 mm thicknes,
covered with 26 gauge aluminum sheet with fixing arrangment / accessories as required
sqm 1100

(J) CONTROLS
1 Controls: 2 way Flow control valve
SITC of 2 Way flow control valve with temperature controller,actuator,Linkage for AHUs as
539 per Specifications.
b 65 mm Ø each 40
c 50 mm Ø each 12

(K) ELECTRICAL PANELS, WIRING & EARTHING

Page-271 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

1 Supply, installation, testing and commissioning of front operated, front / back access, cubicle
type, indoor duty, floor / wall / recess / surface mounted (as specified), totally enclosed dust
and vermin proof switchboards / panels with minimum Ingress protection classification of IP
54, fabricated from 2 mm thick CRCA sheets with dip coat priming and epoxy powder coated
finish. The panels must be suitable for 415 volts 3 phase, 4 wire, 50 Hz, system , must be
able to withstand symmetrical fault level of 65 KA (as specified for panels) for 1 sec at 415 V
and must include all interconnections, earthing and bonding requirements etc. The panels
must conform to drawings & standards specified in relevant specifications. The switch board
shall be as per CPWD specifications, SLD and as required.

540
a All Sub - main LV Switchboards must conform to the specifications.

b All the items mentioned in relevant clauses of the specifications and not specifically
mentioned in BOQ shall be deemed to be included in the quoted rates.

c In case of any contradiction between BOQ / specifications and drawings, the most stringest
conditions of the above will apply.

d The Switchboards shall be provided with detachable gland plates for entry of cables from the
top / bottom as required.
e All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The
busbars shall be insulated with heat shrinkable sleeves. SMC / DMC shrouds and busbar
supports suitably spaced shall be used. Hinged doors with padlocking facility shall be
provided on all outgoing feeders with switch handles lockable in OFF position.

f The panel shall have copper busbars as specified in the Specifications with bar type feeder
connections, spacers etc. with full sized neutral.

g Earthing all components, frame etc. to a common internal earth bar of size 50 x 6 mm Cu. or
higher, as required by the fault withstand level specified for the board.

Page-272 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

h All accessories & supporting structures such as channels, ISMC-75 base frame, mounting
brackets, lifting lugs, panel heaters, ventilation arrangement etc shall be provided as
required.

I Each incomer and outgoing feeder shall be provided with LED type status indication lamps
suitable for 240 V, AC, as approved.

j Space provision as specified in Specifications for future expansion.

k The make of all switchgear (ACB / MCCB / MCB) must be same to have total discrimination.

l Components and accessories shall be same for switchboards and panels for uniformity,
standardisation and replaceability and shall be applicable to all panels/ boards under the
scope of work.

m All interconnections, labeling, earthing, associated foundation / masonary work & erection
etc. complete shall be executed as required.

n MCCBs shall be as per the Specifications and shall be current limiting type with front
adjustable electronic releases for requred protections against fault, suitable for isolation as
per Annexure 7.1.2 of IEC 60947 – 2, with Ics and Icu values as specified in relevant clauses
of specifications and conforming to latest IEC60947. The operating voltage(Ue) shall be 415
V and insulation voltage (Ui) 690V with trip free mechanism, handle indicating ON / OFF /
tripped position. The breaking capacity as mentioned below shall be Ics values and shall not
be less then 50kA. Breakers must have Ics = 100% Icu. Electronic trip units shall comply with
the requirements as specified in Appendix F (EMC /EMI Compatibility) of IEC 60947-2 or EN
60947-2.

o ACBs/MCCBs shall be compact, suitably designed to provide protection of motors, cables,


busbars to suit rated current, unbalanced power distribution, as required.

Page-273 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

p Panel / Switchboard board design shall be compact and components / accessories of


compact sizes shall be used to economise the room space available. Employer reserve the
right to seek compact items inplace of larger ones.

q Incomer ACB'S / MCCBs / MCBs of switchboards / panels shall be provided with NO/NC
contacts as specified in specifications for interface with SCADA & for manual / auto operation
and local / remote operation.

r Voltage rating of shunt trip coil and closing shall be confirmed from BMS contractor during
Working Drawing preparation.

s ACB'a shall have Microprocessor based releases as specified in the Specifications.

t Over load releay for motor feeder shall finally be selected according to motor name plate full
load current by contactor.
u All motor feeder with thermal over load relay shall be provided with reset push button(to reset
in case of over load trip).
v Even though, ratings of MPCB / Contactors for Motor Feeders are mentioned in
BOQ/Drawings on the basis of a particular make of Switchgear, the contractor shall check the
rating with the driven equipment rating and select the the rating of these items accordingly
without any cost implications to the department.

Central Plant Panel as per Specification & Drawing Complete & as per brief description
given below:
One no Incomer consisting of following-

Page-274 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

1 No. 2500 A, 415V, 50kA, 4 Pole, Electrically operated Draw Out type, ACB complete with
safety shutters, 240V AC shunt trip coil & closing coil and having microprocessor based
releases with (1) Communication capability (2) Provision for measurement of three phase
current (3) Protection against long time + short time + earth fault (all with adjustable time
delays) + instantaneous (4) Zone Selective Interlocking Unit for Total Discrimination (5)
Communication options to remotely read and set parameters for the protection functions,
transmission of ammeter measurements (6) Signailing of the cause of tripping and alarms,
maximeter reset etc (7) NO / NC contacts for interlocks and indications (8) 1 no CT in neutral
to connect with the trip unit.

TNC switch
Auto / Local / Remote Selector Switch key operated.
LED indication lamp for ON, OFF & TRIP & Phase indication R-Y-B.
Metering
1 No Digital Voltmeter with In built Selector Switch.
1 No Digital Ammeter with Inbuilt Selector Switch.
3 Nos. CTs 2500/5A, 15VA, CL-1 for metering.
1 Nos. CTs2500/5A, 15VA, CL-1 for APFCR relay.
BUS-BARS
Electrolytic high conductivity T P & N copper conductor bus-bars (as specified in the
Specifications) rated 2500 Amps, suitable to withstand symetrical fault level of 50 KA for 1
second at 415 volts.

OUT GOING FEEDERS


a 3 nos outgoing feeders for Chiller motors of each shall be equipped with the followings but
not limited to:
1 No. 1250 A, 415V, 50kA, 4 Pole, Electrically operated Draw Out type, ACB complete with
safety shutters, 240V AC shunt trip coil and having microprocessor based releases with (1)
Protection against long time + short time + earth fault (all with adjustable time delays) +
instantaneous (2) NO / NC contacts for interlocks and indications (3) 1 no CT in neutral to
connect with the trip unit.

Auto / Local / Remote Selector Switch key operated.


LED indication lamp for ON, OFF & TRIP.
1 No Digital Ammeter with Inbuilt Selector Switch.

Page-275 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

3 Nos. CTs 1250/5A, 15VA, CL-1 for metering.


Power and Control terminals for cable connection.
b 3 Sets of Star - Delta Stater feeders for Primary Chilled Water Pump Motors of and each
shall be equipped with the followings but not limited to:

1 No. 3 Pole 100 A, 50kA at 415V, 3P Motor Duty MCCB (with inbuilt over load and short
circuit protection and having add-on type earth leakage protection ) over load range 30-50 A,
and auxiliary Contacts.
1 No. Digital Ammeter, CT operated.
1 No. CT 100/5A, 10VA, class - I for metering.
3 Nos. Contactors
1 No. overload relay
1 Lot interconnections, lugs and cable glands as required.
c 3 Sets of Star - Delta Stater feeders for Secondary Chilled Water Pump Motors of and each
shall be equipped with the followings but not limited to:

1 No. 3 Pole 100 A, 50kA at 415V, 3P Motor Duty MCCB (with inbuilt over load and short
circuit protection and having add-on type earth leakage protection ) over load range 30-50 A,
and auxiliary Contacts.
1 No. Digital Ammeter, CT operated.
1 No. CT 100/5A, 10VA, class - I for metering.
3 Nos. Contactors
1 No. overload relay
1 Lot interconnections, lugs and cable glands as required.
d 3 Sets of Star - Delta Stater feeders for Condenser Water Pump Motors of and each shall
be equipped with the followings but not limited to:

1 No. 3 Pole 160 A, 50kA at 415V, 3P Motor Duty MCCB (with inbuilt over load and short
circuit protection and having add-on type earth leakage protection ) over load range 100-125
A, and auxiliary Contacts.

1 No. Digital Ammeter, CT operated.


1 No. CT 100/5A, 10VA, class - I for metering.
Auto / Local / Remote Selector Switch key operated.
Working / Standby Selector Switch key operated.
Door mounted push buttons for Start and Stop functions.
Emergency stop push button lockable type.
LED indication lamp for ON, OFF, Trip.
3 No. 80A, AC-3 Duty, 3 - pole Contactor with Auxiliary Contacts and Operating Coil of 230 V
AC.
One no star delta timer.
Auxiliary Contactors for Auto / Local / Remote Operation.

Page-276 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

Power & control terminals for cable connections.


e 3 Sets of Star - Delta Stater unit for Cooling Tower Fan Motors of and each shall be
equipped with the followings but not limited to following:

1 No. 3 Pole 100 A, 50kA at 415V, 3P Motor Duty MCCB (with inbuilt over load and short
circuit protection and having add-on type earth leakage protection ) over load range 25-30 A,
and auxiliary Contacts.
1 No. Digital Ammeter, CT operated.
1 No. CT 100/5A, 10VA, class - I for metering.
Auto / Local / Remote Selector Switch key operated.
Working / Standby Selector Switch key operated.
Door mounted push buttons for Start and Stop functions.
Emergency stop push button lockable type.
LED indication lamp for ON, OFF, Trip.
3 No. 80A, AC-3 Duty, 3 - pole Contactor with Auxiliary Contacts and Operating Coil of 230 V
AC.
One no star delta timer.
Auxiliary Contactors for Auto / Local / Remote Operation.
Power & control terminals for cable connections.
f 2 Nos. 100 A, MCCB 4P, 25 KA Thermal Magnetic Based O/C S/C Release, RHOM.
each 1

2 SITC & Handing over of Wall mounted FCU panel board of cubical type fabricated from 2.0
mm thick CRCA Sheet having necessary cable alleys, powder coated through seven tank
process facility for picking and degreasing, including connections and interconnections as per
specifications for AHU motors only, including starters, contactors as per drawing approved
by the department.and and controls where applicable). Bus-Bar shell of copper, and the
incoming will have face indication lamps, and volt meter / ammeter with selector switch.

541 each 62

3 SITC & Handing over of Wall mounted AHU panel board of cubical type fabricated from 2.0
mm thick CRCA Sheet having necessary cable alleys, powder coated through seven tank
process facility for picking and degreasing, including connections and interconnections as per
specifications for Strip Heaters only including contactors for strip heaters as per drawing
approved by the department.and and controls where applicable.

542 each 35

Page-277 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

3 Chiller -LT Panel inter conection 1000 A Bus Trunking (sand-wich tipe,
65 ka/second, IP-55, C&S, L&T & GE make) arrangement in convenient sections with
Aluminium Bus Bars designed for a current density of 130 Amps per mm2 for use on 3phase
4 wire,415 Volts,50 Hz., A.C.supply including joints of sections, flexible joints, expansion
joints, bends and earthing with 2 runs of G.I. strip etc as per CPWD specfications and as
required.

543 mtr 45

4 SITC of Copper Conductor cable of suitable size for inter conection of Electrical Panal with all
the motors including their termination in to required cable end boxes, laid in ground / in trench
/ cable tray, as requred. Cable sizes will be as per CPWD specification.
544 job 1

5 Copper Plate Earthing


SITC of earthing station with copper plate of size 600 mm X 600 mm X 3 mm including
accessories like 40 mm dia pipe,masnory enclosure with cover plate having locking
arrangement,watering pipe, charcoal and salt complete as per CPWD specification and as
required.

545 lot 1

6 Providing and fixing of 25 mm X 5mm copper strip in 40 mm dia G.I Pipe from earth electrode
546 as required. mtr 100

7 Providing and fixing of 25 mm X 5 mm copper strip on surface or in recess for earth


connections per CPWD specification etc complete as required.
547 mtr 10

8 Providing and fixing 6 SWG dia GI Wire on surface or in recessfor loop earthing complete as
548 required. mtr 1500

9 Electrical Control wiring(Excluding BMS wiring): Providing & Fixing of Multicore armored
control (1.5 mm² copper) cabling, as required, for control and inter locking between electrical
panels and all field mounted controls.
This shall include all necessary control wiring as Following:
# Chillers to main panel.
# AHU two way valve modulating motor Controls to Panels, control wiring for thermostats,
safety thermostat, for heaters arranged in banks of 9 K.W.

549 lot 1

550 10 Supply & laying of rubber mat of size 1000 mm & 12 mm thick. sqm 30

Page-278 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

11 Supply & installation of ladder type 2 mm thick MS 'U' shaped channel tray ( including
horizontal & Vertical bends, reducers tees,cross member & other accessories as required &
duly suspended from the celling with M.S. suspenders ) of following sizes:

551
a 40 x 150 x 2 mm wide mtr 500
b 50 x 300 x 2 mm wide mtr 200
c 50 x 600 x 2 mm wide mtr 50

12 Providing and laying of double wall corrugated HDPE pipes, Rex / Zenduct / Duraline make
and of following sizes in existing channel or trench / ground / on surface including providing
and fixing necessary sockets / couplers / bends etc. on the way complete as required.
552
a 175mm (OD) / 150mm (nominal) (ID) mtr 1500
b 120mm (OD) / 100mm (nominal) (ID) mtr 1000

13 SITC of 100 A FP MCCB in enclosure (in MS box) including connection / interconnection


etc. as required Conforming to Specification for cooling tower.
553 each 3

(L) OZONE GENERATOR AND INJECTION SYSTEM FOR COOLING TOWERS


1 Supply, installation, testing and commissioning of Ozone Generator and Injection System for
Cooling Towers Capable of delivering 300 gm / hr at 10% wt.wt comprising of the following
and complete as per specifications.
554
i) 1 no. PLC based control panel comprising of Programmable logic controller, power
supply unit, Switch mode power supply, relay board, HT Transformer & DOL controller along
with HMI for pumps along with necessary switchgars for smooth operationof plant.
ii) 1 no. Air compressor non lubricating, reciprocating type having capacity
80CFM,1440RPM 95% filtering efficiency along with anti vibration pad etc. iii)
1 no. Oxygen plant (PSA based) iv) 1 no. Ozone electrode, vertical,
tubular, dual pass, water cooled 800gm/hr capacity made of SS316 with individual fused HT
element v) 1 no. hermatic reciprocating, air cooled water chiller
for operation on 3 phase, 415V AC supply. vi) 1no. Chiller pump set for
electrode cooling complete with end sectio, horizontal split casing, centrifugal pump with
TEFC induction motor, class 'F' insulation operating on 415 + 10 % volts, 3 phase, 50 cycles
AC supply.

Page-279 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

vii) 1 no. Recirculation pump set for compressor cooling complete with 1 no. end section,
horizontal split casing, centrifugal pump.TEFC induction motor class 'F' insulation operating
on 415 + 10% volts, 3 phase, 50 cycles AC supply.
viii) 1 no. Booster pump set with end suction, horizontal split casing, centrifugal
pump. TEFC induction motor, class, 'F' insulation operating on 415+ 10% volts, 3 phase, 50
cycles AC supply.

ix) 1 no. Liquid jet compressor (venturi injector)


x) 1 set. Non return valve and ball valve.
xi) 1 set, needle valve
xii) 2 set, rotatype flowmeter
xiii) 1 set, pressure indicator
xiv) 1 set, Solenoid valve
xv) 1 set, Water pressure switch
xvi) 1 no., Oxygen pressure switch
xvii) 1 no., Air filter having 5 micrometer filteration degree
xviii) 1 no., Air filter (mist separator) having 0.3 micrometer filteration degree

xix) 1 no. Air filter (micro mist separator) having 0.01 micrometer filteration degree

xx) 1 no side stream filtration with sand filter, filter pump & corrosin coupon rack

xxi) 1 lot, concrete foundationas required for the equipment. job 1

(M) BUILDING MANAGEMENT SYSTEM


1 Supply, Installation, testing and commissioning of Central Work Station of BMS comprising of
555 following. job 1
a Intel Pentium ( Latest ) machine with 2. GHz speed, 2.0 GB RAM 120 GB HDD,
Multimedia extenal modem as per specifications.
b Colour Monitor LCD - 21 inch
c 132 column 240 CPS printer (Alarm and report)
d Mouse
e UPS with 30 minutes battery backup

2 Supply, Installation, testing and commissioning of Software and System Interface Units of
556 BMS comprising of following.
a Developing, testing and commissioning of the software for the building automation
system along with necessary license.The Software shall be Web Based with unlimited IO
Points and User licenses. The BMS Software shall have on board Energy Report module ,
SMS and email alerts .The system software shall be Natve BACnet compliant. All controllers
shall be BTL ceitified & UL listed
each 1

Page-280 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

b Providing all necessary software and hardware for the interface of the following
system/equipment including providing necessary integrators/modules.
Water Cooled Chiller, Fire Alarm System , Diesel Generators , Secondary Pump VFDs.

lot 1
c Providing necessary BMS Interface Gateways for the BMS DDCs for Block A 1, A3 , B, C, D.
lot 1

3 Supply, lnstal!ation,testing and commissioning of following controllers as per the


557 specifications:
a Standalone 16/ 32 Bit Microprocessor Based intelligent Controller with real Time Clock,
Peer To Peer Communication & EEPROM as per the specifications. The
Contractor shall Estimate the required quantities of controller to suit the complete
requirement / operation as per I/O summary. The Controller shall be housed in lockable and
secure MS cabinets to be supplied along with controllers . System architecture design should
be in such a manner that every individual DDC is having at least 10% space I/O Point.
Communication protocol shall be Native BACnet at DDC level.

lot 1
b LCD Hand Held Portable Operator Terminals. each 1

4 Sensors and Field Devices


Supply, Installation, testing and commissioning of the following sensors / transmitters /
transducers / field devices as per the specifications.
558
a Immersion type temperaure sensors for measuring chilled water & condenser water supply
and return temperature each 5
b Duct type temperauture sensor for measuring return air at the Air Handling units.
each 36
c Duct Type Return Air Humidity Sensers for Return Air. each 36
d Out side air temperature Sensor for measuring the outside air temperature.
each 1
e Outsdie air humidity sensor each 1
f Pressure transmitter for measuring pressure in water lines each 4
g Electromagnetic type flow meters for Chilled water header each 1
h Differential Pressure switch across the Air Handling Units filters for indicating the filter status
each 36
i Differential Pressure switch across the Fan sections for indicating the fan status
each 36
j Level switches for indicating water levels in cooling towers, Tanks each 21
k Differential Pressure switch for pumps status each 12
l Duct CO2 sensors each 28

Page-281 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

m CO2 sensor with Outdoor enclosure each 1


n Flameproof Level switch each 3
o Flameproof Level transmitter each 1
p Voltage Transducer each 4
q Ph Sensor each 1

5 Supply,Installation.testing and commissioning of the following cables & Conduit as per


559 specifications :
a Signal cable , 2 Cx 1.5 Sq. MM., stranded tinned Cu conductor, Standard flexible, PVC
sheathed type. mtr 9250
b Communication cable 2Cx 1.5 Sq. MM , stranded tinned Cu conductor, flexible, PVC
sheathed, Shielded type. mtr 1500
c MS Conduits 25 mm mtr 5550
d MS Conduit 20 mm mtr 1500
Total Price of Section G

SECTION-H - LANDSCAPING
1 GRADED STONE AGGREGATE
Supplying and stacking of graded stone aggregate at site of size range :
560
a) 45 to 63 mm CUM 386.00

BRICKWORK
2 Brickwork with machine moulded perforated bricks of class designation 75 confirming to IS :
2222 -1991 in superstructure above plinth level upto floor five level in cement mortar 1:6 ( 1
cement : 6 coarse sand )
561 CUM 535.00
With F.P.S. bricks

3 PAVING/FLOORING
40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1
cement :5 coarse sand) with joints 3mm thick, side buttered with cement mortar 1:2 (1
cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with
same mortar
562
White sand stone SQM 890.00

4 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey
cement slurry mixed with pigment to match the shade of the slab including rubbing and
polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
563

Page-282 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

25 mm thick. SQM 416.00

5 Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished)
machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations
of required size of approved shade, colour and texture laid over 20mm thick base cement
mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with
matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to
edge to give high gloss finish etc. complete at all levels.

564
Area of slab over 0.50 sqm. SQM 250.00

565 6 Fire Clay Brick -Planting bed edging


Machine Made wire cut Fire clay bricks for paving & flooring pattern as/dwg. of size
230x115x40mm in approved make in all colours & shades, of any size as approved by
Engineer-in-Charge, over 12 mm thick bed of Cement Mortar 1:3 (1 Cement:3 Coarse Sand)
including necessary cutting, mitring, grouting the joints with fine, water-resistant, polymer
modified cement based powder grout mixed with pigment to match the shade of brick
complete.
SQM 135.00

7 40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1
cement :5 coarse sand) with joints 3mm thick, side buttered with cement mortar 1:2 (1
cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with
same mortar
566
Red sand stone SQM 350.00

8 PRECAST CONCRETE GRASS GRID PAVERS for Greenbelt pathway


567
Providing and laying 80mm thick factory made precast concrete interlocking grass grid
paving block of approved shape and of approved make over 80mm thick sand bed laid to
required gradient and finishing & cleaning of surface etc. all complete.
SQM 823.00

568 9 PRECAST CONCRETE DRAIN COVER


Providing & fixing in position precast concrete drain cover & frame of required shape &
approved quality of size 400 x 550 x75 NOS 1110

569 10 CURB STONE

Page-283 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

Providing and laying at or near ground level factory made kerb stone of M-25 grade cement
in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement:
3 coarse sand) including making joints with or without grooves (thickness of joints except at
sharp curve shall not to more than 5mm) including making drainage opening wherever
required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging
shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-
charge).

CUM 851.00

STEEL: BENCHES, LITTER BINS AND SIGNAGES


11 BENCHES
i Providing and fixing wrought iron / stainless steel benches as per approved manufacturer
570 each 65.00

ii SIGNAGES
Providing and fixing custom fabricated signage towers as per drawing and specifications i/c
materials using MS framework, SS finish, polycarbonate, vinyl and translights with composite
aluminum and SS base.
571
S1 nos 6.00
S2 nos 23.00

iii LITTER BINS


Providing and fixing GRP Fibre Sheet litter bins of approved manufacturer as per
572 specification. each 30.00
12 HORTICULTURE
12.1 Planting of Trees including cost of plants and necessary excavation of pits for plants as
573 shown in drawing no. 08008 B S5 LMP 001
T1 Alstonia scholaris ( Chhalm / Devils tree ) no. 70
T2 Azadirachta indica ( Neem ) no. 110
T3 Butca Monosperma( Butca, Palas, Dhak ) no. 50
T4 Cassia Fistula ( Amaltas ) no. 150
T5 Dekmix regia ( Gulmohur ) no. 175
T6 Emblica officianalis ( Amla ) no. 80
T7 Madhuca indica ( Madhuca / Mabua ) no. 75
T8 Mangifera indica ( Mango ) no. 75
T9 Polyenthia longifolia ( Ashoka ) no. 100
T10 Syzgium Cumini ( Jamun ) no. 75
T11 Tamarindus indica ( Imli ) no. 85
T12 Terminalia Arjuna ( Arjun ) no. 25

Page-284 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

12.2 Planting of Shrubs including cost of shrubs and necessary excavation as directed by
574 Engineer-in-charge. no. 1200

12.3 Trenching in ordinary soil up to a depth of 60cm including removal and stacking of
serviceable materials and then disposing of by spreading and neatly levelling with in a lead of
50m and making up the trenched area to proper levels by filling with earth or earth mixed with
sludge or/and manure before and after flooding trench with water (excluding cost of imported
earth, sludge or manure).
575 Cum 6000
12.4 Supplying and stacking of good earth at site including royalty and carriage up to 1 km (earth
measured in stacks will be reduced by 20% for payment).
576 cum 4000
12.5 Supplying and stacking sludge at site including royalty and carriage up to 1 km (sludge
measured in stacks will be reduced by 8% for payment).
577 cum 1000
12.6 Supplying and stacking at site dump manure from approved source, including carriage up to
1 km (manure measured in stacks will be reduced by 8% for payment) :
578
Screened through sieve of I.S. designation 4.75mm cum 1000
579 12.7 Rough dressing the trenched ground including breaking clods. 100sqm 20000
12.8 Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water
580 including disposal of uprooted vegetation. 100sqm 20000
581 12.9 Fine dressing the ground 100sqm 20000
12.10 Spreading of sludge, dump manure or/and good earth in required thickness (Cost of sludge,
dump manure or/ and good earth to be paid separately).
582 cum 6000
12.11 Mixing earth and sludge or manure in proportion specified or directed.
583 cum 6000
12.12 Grassing with ‘Doob’ grass including watering and maintenance of the lawn for 30 days or
more till the grass forms a thick lawn free from weeds and fit for mowing including supplying
good earth if needed (the good earth shall be paid for separately).
584
In rows 7.5 cm apart in either direction. 100sqm 20000

12.13 Half brick circular tree guard in 50 class designation bricks, internal diameter 1.25 metre and
height 1.2 metre above ground and 0.20 m below ground bottom two courses laid dry and top
three courses in cement mortar 1:6 (1 cement : 6 fine sand) and the intermediate courses
being in dry honey comb masonry as per design complete:
585
With F.P.S bricks each 1070.00

D LIGHTING FIXTURES

Page-285 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SL. NO. ITEM NO. ITEM DESCRIPTIONS UNIT QUANTITY AMOUNT (RS)

Providing as fixing with complete cabling and other provisions required to mount following
light fixtures as per design / manufacturer as per drawing
586
1 L1 4.5m High Pole Light nos 39

2 L2 Alura 3.0M high Conical Post nos 6

3 W1 Water light with 20W LED with IP 68 protection nos 9

4 W2 Down light in water body with 40W LED nos 9

5 L3 Mini Bollards nos 8

6 Solar Garden Light


SITC of Solar Bollard Garden Light Aluminium profile with Diecast base, painted with PU
with frosted diffuser, corrote with 3 watt LED luminaire and solar charged battery, 1m high
along with CC foundation as reqd. ( TDM / HILITE / Bajaj)
nos. 250

Total Price of Section H

Page-286 of 288
file:///opt/scribd/conversion/tmp/scratch14637/55812467.xls\55812467.xls SOR-BSC
SUMMARY SHEET OF SOR

NAME OF WORK: CIVIL, STRUCTURAL, ELECTRICAL AND OTHER DEVELOPMENTAL WORKS


NAME OF PROJECT: CONSTRUCTION OF CAMPUS OF THE BIO-TECH SCIENCE CLUSTER(PHASE 1), FARIDABAD, HARYANA.
Bidding Doc. No.: A091/T-36/10-11/BB/01

Name of Bidder:

Sl. No. Section in SOR Description Amount in Rs.(in figures)


1 A Civil Works
2 B Internal Electrical Installation
3 C External Electrical Installation
4 D Pumps, Water Treatment & Allied Equipment
5 E Sewerage Treatment Plant(STP)
6 F Audio Visual System
7 G HVAC work
8 H Landscaping

Total Price.=(A)+(B)+( C)+(D)+(E)+(F)+(G)+(H)

Rebate/Discount (if any)


Percentage of Rebate/ Discount (for no rebate relevant column to be filled by zero.)
In figures (%) in words.

Grand Total i.e. Total Price after Rebate/ Discount = (P-Q)

SIGNATURE OF BIDDER WITH SEAL


PHASE 1), FARIDABAD, HARYANA.

Amount in Rs.(in words)


(A)
(B)
(C)
(D)
(E)
(F)
(G)
(H)

(P)

(Q)

E OF BIDDER WITH SEAL