LINE DATA

DATE: 15 DECEMBER 2007

MH No. 34/1/27/29/14/4 Pipe Dia : 300 mm Ø MH No. 34/1/27/29/14/5


IL : 5.830m (GRP Lined RC Pipe) Lenght : 77.99 meters IL : 5.980m (GRP Lined RC Pipe)
IL : 5.559m (Jacking Steel Pipe) Slope : 0.00192 IL : 5.709m (Jacking Steel Pipe)
TBM BS HI
6.89 -0.680 6.210
*Design Reqr'd. Actual Total *Actual Difference
Chainage Invert Level Rod Reading Rod Reading Invert Level (*AL-*DL) Remarks
(m) (m) (m) (m) (mm)
0.00 5.559 MHA/14/5
2.10 5.563 0.647 0.215 0.720 5.490 0.073 Center
4.60 5.568 0.642 0.208 0.727 5.483 -0.085 1
7.10 5.573 0.637 0.253 0.682 5.528 -0.045 2
9.60 5.577 0.633 0.242 0.693 5.517 -0.060 3
12.10 5.582 0.628 0.258 0.677 5.533 -0.049 4
14.60 5.587 0.623 0.311 0.624 5.586 -0.001 5
17.10 5.592 0.618 0.31 0.625 5.585 -0.007 6
19.60 5.597 0.613 0.329 0.606 5.604 0.007 7
22.10 5.601 0.609 0.34 0.595 5.615 0.014 8
24.60 5.606 0.604 0.335 0.600 5.610 0.004 9
27.10 5.611 0.599 0.349 0.586 5.624 0.013 10
29.60 5.616 0.594 0.349 0.586 5.624 0.008 11
32.10 5.621 0.589 0.33 0.605 5.605 -0.016 12
34.60 5.625 0.585 0.357 0.578 5.632 0.007 13
37.10 5.630 0.580 0.349 0.586 5.624 -0.006 14
39.60 5.635 0.575 0.357 0.578 5.632 -0.003 15
42.10 5.640 0.570 0.362 0.573 5.637 -0.003 16
44.60 5.645 0.565 0.371 0.564 5.646 0.001 17
47.10 5.649 0.561 0.372 0.563 5.647 -0.002 18
49.60 5.654 0.556 0.389 0.546 5.664 0.010 19
52.10 5.659 0.551 0.409 0.526 5.684 0.025 20
54.60 5.664 0.546 0.398 0.537 5.673 0.009 21
57.10 5.669 0.541 0.399 0.536 5.674 0.005 22
59.60 5.673 0.537 0.41 0.525 5.685 0.012 23
62.10 5.678 0.532 0.411 0.524 5.686 0.008 24
64.60 5.683 0.527 0.429 0.506 5.704 0.021 25
67.10 5.688 0.522 0.444 0.491 5.719 0.031 26
69.60 5.693 0.517 0.438 0.497 5.713 0.020 27
72.10 5.697 0.513 0.436 0.499 5.711 0.014 28
74.60 5.702 0.508 0.435 0.500 5.710 0.008 29

Surveyed By: Noted By: Checked By: Approved By:

____________ ____________ ____________ ____________


AJECT NICC Inspector ARE
LINE DATA
DATE: 15 DECEMBER 2007

MH No. 34/1/27/29/14/4 Pipe Dia : 935 mm Ø MH No. 34/1/27/29/14/5


IL : 5.830m (GRP Lined RC Pipe) Lenght : 77.99 meters IL : 5.980m (GRP Lined RC Pipe)
IL : 5.559m (Jacking Steel Pipe) Slope : 0.00192 IL : 5.709m (Jacking Steel Pipe)

TBM 6.89 BS -0.68 HI 6.210

*Design Reqr'd. Actual Total *Actual Difference


Chainage Invert Level Rod Reading Rod Reading Invert Level (*AL-*DL) Remarks
(m) (m) (m) (m) (mm)
0.00 5.559 MHA/14/5
2.10 5.563 0.647 0.215 0.720 5.490 -0.073 Center
4.60 5.568 0.642 0.208 0.727 5.483 -0.085 1
7.10 5.573 0.637 0.253 0.682 5.528 -0.045 2
9.60 5.577 0.633 0.242 0.693 5.517 -0.060 3
12.10 5.582 0.628 0.258 0.677 5.533 -0.049 4
14.60 5.587 0.623 0.311 0.624 5.586 -0.001 5
17.10 5.592 0.618 0.31 0.625 5.585 -0.007 6
19.60 5.597 0.613 0.329 0.606 5.604 0.007 7
22.10 5.601 0.609 0.34 0.595 5.615 0.014 8
24.60 5.606 0.604 0.335 0.600 5.610 0.004 9
27.10 5.611 0.599 0.349 0.586 5.624 0.013 10
29.60 5.616 0.594 0.349 0.586 5.624 0.008 11
32.10 5.621 0.589 0.33 0.605 5.605 -0.016 12
34.60 5.625 0.585 0.357 0.578 5.632 0.007 13
37.10 5.630 0.580 0.349 0.586 5.624 -0.006 14
39.60 5.635 0.575 0.357 0.578 5.632 -0.003 15
42.10 5.640 0.570 0.362 0.573 5.637 -0.003 16
44.60 5.645 0.565 0.371 0.564 5.646 0.001 17
47.10 5.649 0.561 0.372 0.563 5.647 -0.002 18
49.60 5.654 0.556 0.389 0.546 5.664 0.010 19
52.10 5.659 0.551 0.409 0.526 5.684 0.025 20
54.60 5.664 0.546 0.398 0.537 5.673 0.009 21
57.10 5.669 0.541 0.399 0.536 5.674 0.005 22
59.60 5.673 0.537 0.41 0.525 5.685 0.012 23
62.10 5.678 0.532 0.411 0.524 5.686 0.008 24
64.60 5.683 0.527 0.429 0.506 5.704 0.021 25
67.10 5.688 0.522 0.444 0.491 5.719 0.031 26
69.60 5.693 0.517 0.438 0.497 5.713 0.020 27
72.10 5.697 0.513 0.436 0.499 5.711 0.014 28
74.60 5.702 0.508 0.435 0.500 5.710 0.008 29

Surveyed By: Noted By: Checked By: Approved By:

____________ ____________ ____________ ____________


AJECT NICC Inspector ARE
line data forrm/cac
LINE DATA
Date: ______________
Checking of Steel Sleeve Pipes Time: ______________

MH No. 34/1/27/29/5/1 Pipe Dia : 300 mm Ø MH No. 34/1/27/29/5/3


IL : 4.26m (GRP Lined RC Pipe) Length : 58.50 meters IL : 4.46m (GRP Lined RC Pipe)
IL : 4.577m (Jacking Steel Pipe) Slope : ________ IL : 4.777m (Jacking Steel Pipe)
From MH:
34/1/27/29/5/1 TBM ________ BS ________ HI ________

*Designed Required Actual Total *Actual Difference


Chainage Invert Level Rod Reading Rod Reading Invert Level (*AL-*DL) Remarks
(m) (m) (m) (m) (mm)
0.00 4.577 MH
2.30 4.585 Center
4.80 4.593
7.30 4.602
9.80 4.611
12.30 4.619
14.80 4.628
17.30 4.636
19.80 4.645
22.30 4.653
24.80 4.662
27.30 4.755
29.80 4.679
32.30 4.772
34.80 4.645
37.30 4.705
39.80 4.713
42.30 4.722
44.80 4.730
47.30 4.739
49.80 4.747
52.30 4.756
54.80 4.764
57.30 4.773
59.80 4.577
62.30 4.790

Surveyed By: Noted By: Checked By: Approved By:

____________ ____________ ____________ ____________


line data form/cac
AJECT NICC Inspector ARE

line data form/cac


0.935

58.5
4.46 4.26
0.003419