Environmental Monitoring

ESM Andersen Instruments

The ESM Solutions for


Particulate and Ambient
Air Measurement

Collocated FH 62 I-R Monitors


120

100

80

60
C in µg/m3

40

20

-20
30. 12. 01.01. 03.01. 05.01. 07.01. 09.01. 11.01.
Date

ISO 9001
No. 1 in Continuous Particulate Monitoring

comfortable in mobile applications. It is a


Suspended particles in ambient air firm device in which external vibrations do
serve as a transport medium for not effect the measurement. No warm-up
organic and inorganic compounds. time!
When a person inhales these
contaminated particles, bronchitis Size selective – Various inlets with
syndromes or lung and pulmonary different cutpoints allow a size
health problems may occur. Air selective concentration measurement.
quality stations and networks observe Ambient parameters (pressure and
the pollutant components for health temperature) are measured to control
protection of the population. Also the air flow rate (no cutpoint shifts).
around and in industrial sites they are Due to the very low detection limits the
measured for industrial hygiene. ESM FH 62 I-R is able to measure precisely
Andersen Instruments has developed very small particulate fractions.
a wide range of instruments to
provide complete solutions for all
specific requirements in particulate
monitoring. THE FLAGSHIP
ESM Andersen Instruments GmbH is The FH 62 I-R
the former FAG Radiation Particulate Monitor
Measurement Division. The company utilises the radiometric
started with the development and principle of beta-
industrial production in Erlangen/ attenuation by a dual
Germany more than 50 years ago and beam compensation
is today one of the world leaders in method. The special
particulate measurement. Together advantage is to
with our US sister companies Ander- measure the mass
sen and MIE we are members of the concentration
Thermo organization, a dynamically continuously during
expanding group of laboratory and sampling.
monitoring equipment producers.

Applications
Networks – The FH 62 I-R is designed
to fulfill all needs of networking
installations. The experience of more
Approvals and Suitability
than 2,000 FH 62 monitors installed Tests
worldwide is included. It is a high Corresponding to the thoracic
performance solution with unmatched USA convention of ISO 7708, ISO 10473
special features. Approval of the Environmental (Beta Ray Absorption)
Protection Agency (EPA). Beta
Working place – A continuous monitor Attenuation Monitor FH 62 I-N with GERMANY
for a quick response, a wide measuring PM 10 inlet: Suitability Test: TÜV Approval-Report
range, two selectable limit values and EPA-Test-No. EQPM-0990-076 no. 240 12 676 (1995);
internal data storage for half hour (Fed.Reg., Vol. 55, No. 181-1990) published in the Federal Gazette of
average concentration values over a Ministers (GMBI) No. 33 (1995)
whole year. The sampled particles are EUROPE page 703.
available for a subsequent laboratory European TÜV Test Report The instruments of the type FH 62 I:
analysis. no. 24022605 according to the VDI-guideline 2463 part 5 (ISO/DP
European Standard 10473). Radiation protection approval
Mobile – The FH 62 I-R's quick response EN 12341 to comply with the Council of the Federal Republic of Germany;
and very low detection limit make it very Directive 1999/30/EC. License no. By 43/95

2
Dual Beam Compensation

Important Features Operation Principle Technical Data


 Top quality measurement. The Single Filter Spot Principle is Measuring range:
 Monitoring of extreme low used: A new cycle starts when a clean 0 to 5,000 µg/m3 or
concentration levels. section of the filter tape moves into the 0 to 10,000 µg/m3
measuring position. The filter spot Detection limits:
 Dual beam compensation method
typically remains 24 h in place (2) typ. 4 µg/m3 (measured values)
eliminates physically temperature
until full load has been reached. typ. 3 µg/m3 (1/2 hour average)
and pressure changes. This provides
Ambient air is pulled through the typ. 2 µg/m3 ( 3 hour average)
a very stable measurement over a
sampling system. Dust particles are typ. 0.5 µg/m3 (24 hour average)
very long period.
deposited on the filter. The increasing Correlation coefficient:
 Easy set-up and operation. dust layer weakens the intensity of the R ≥ 0.98
 Time-saving air flow calibration beta beam in the section (4-2-1). The Precision of 2 monitors:
with the ESM air flow calibration electric signal at the output A is 1 µg/m3 (24 h)
kit. Compared flow rates are proportional to the actual sampled Measurement:
calibrated easily by the operation mass. From the temporal increase of On-line, continuous mass and mass
menu. the dust mass and the measured air concentration during sampling.
 Simple and fast mass calibration flow rate, the concentration is Automatic filter change typically
with the ESM mass calibration kit. calculated and displayed. every 24 h.
Results in the same sensitivity and Short term averaging:
accuracy e.g. of all units in a The measuring head (1-7) is built 4 seconds with 1 second scanning time
network. symmetrically in respect to the beta Long term average concentration:
source (4). Therefore air mass changes 30 min; 1 h; 3 h; 24 h
 Automatic internal checks with
in the active volumes due to Air flow rate:
status reports and detailed logbook
temperature or pressure changes as 1 m3/h through the filter (no loss of
entries for quality assured
well as supply voltages drifts are particles due to flow splitter
measurement data.
compensated intrinsically. Ionization Internal flow rate measurement and
 No loss of volatile mass chambers are distinguished as control:
components. detectors because they have the best stability < 1 %
 Accurate sampling efficiency long term stability, operational life with RPM-regulated pump
without "flow splitter" or "dryer". time and the less influence on Time between calibration checks and
 Extremely low maintenance costs efficiency by high voltage and maintenance:
given by one year stand alone and temperature changes. 12 months (if used as specified)
maintenance-free operation. = one year stand-alone running
 Special safety beta source box. The current air flow rate is exactly without any service
measured with an orifice plate. The Power supply:
 Customer specific options. RPM-regulated rotary vane pump is 100 V to 240 V; 50 to 60 Hz
provided for accurate air flow rate (± 10%)
control. Dimensions:
Width 483 mm (19")
Height 310 mm (7 HU)
Display
Key´s
Depth 320 (380) mm
A Weight: approx. 45 kg
ADC
Source:
+ CPU
DAC
Krypton-85; 1.85 GBq (= 50 milli
1
Curie); special safety source
2 analog
I/O
digital
I/O
Analog output signals:
3
4 Two independent channels
5 RS232

6 1 Measurement I-chamber
0/4 ... 20 mA or
7
DP
Com2 Com1
2 Dust sampling 0/2 ... 10 V (selectable)
3 Suction chamber
4 Kr-85 gaseous source
Printer/computer connection:
-
5 Compensation chamber 1 Two V 24/RS 232 C serial
6 Compensation chamber 2 interfaces
'ESM Andersen Instruments' 7 Compensation I-chamber

3
FH 62-1:
Single Beam Compensation

THE ECONOMICAL SOLUTION

The FH 62-1 utilizes as well as the


FH 62 I-R the radiometric principle of
beta-attenuation by an accumulated
dust layer. In contrary to the FH 62 I-R
it has a single beta beam. It is also
designed to measure the mass
concentration continuously and is a
low budget alternative.

Technical Data
Measuring range:
0 to 5,000 µg/m3 and
0 to 10,000 µg/m3
Detection limits:
typ. 7 µg/m3 (measured values)
typ. 5 µg/m3 (1/2 hour average)
typ. 3 µg/m3 ( 3 hour average)
typ. 1 µg/m3 (24 hour average)
Precision of 2 monitors:
2 µg/m3 (24 h)
Air flow rate:
0.6 - 1.4 m3/h (selectable)
Internal flow rate measurement and
control:
Stability < 1 %
Power supply:
100 V to 240 V:
50 to 60 Hz (± 10 %)
Operation Principle
Dimensions:
The operation principle corresponds to Good measurement stability is
Width: 483 mm (19")
the FH 62 I-R. The dust particles are achieved compensating air mass
Height: 310 mm (7 HU)
sampled on a filter (2) and beta changes in the active volume by
Depth: 320 (380) mm
particles in the measuring path (4-2-1) temperature and pressure sensors.
Weight: approx. 40 kg
are attenuated due to the increasing
Source:
dust layer.
Krypton-85; 1.85 GBq (=50 milli
Curie); special safety source
Analog output signals:
Two independent channels I meas
ADC RAM ext.

0/4 ... 20 mA or 0/2 ... 10 V DAC EEPROM

(selectable)
Com1

Printer/computer connection: 1
I comp
sensors
RS232

Two V 24/RS 232 C serial 2 CPU


Com2

Filter tape

interfaces 3
analog digital
4 I/O I/O

options LC-Display
&
1 Measurement I-chamber µg softkeys
µg/m3
2 Dust sampling
3 Suction chamber
4 Kr-85 gaseous source 'ESM Andersen Instruments'

4
Sampling Systems

AVOCS PUF

Ambient Volatile Organic Collection (PolyUrethane Foam) Sampling


System System
Andersen AVOCS collects whole The PUF Sampler is a complete air
ambient air samples for subsequent sampling system designed to
laboratory analysis of volatile organic simultaneously collect suspended
compounds (VOC's). The microprocessor airborne particulates as well as trap
controller provides a user-friendly airborne vapors at flow rates up to
interface, allowing maximum flexibility 280 liters per minute.
when selecting sampling options.
The Model GPS-1 features the latest in
 Microprocessor control with RS 232 technological advances for accurately
standard. measuring airborne particulates and
 Remote module activation and vapors. The PUF Sampler is equipped
programming. with a bypass blower motor arranged
with an independent cooling fan. This
 Up to 17 separate sampling periods.
feature permits the motor to operate at
 Capable of collecting multiple low sampling flow rates for extended
sequential samples into the same periods without motor failure from
canister. overheating.
 Samples up to 16 canisters.
Optional 16 port auto valve system.
 Samples can be segregated by wind
speed or direction (sector sampling).
 Meets PAMS sampling
requirements of eight (3) hour
sampling periods totaling 24 hours,
into eight individual canisters.
 User selectable flow rates with mass
flow control option.
 Optional serial printer.
 Quality assurance checks.

Air Sampling SUMMA Canisters


SUMMA Electropolished Stainless
Steel Canisters meet all requirements
of US EPA Compendium Method TO-
14. The canister meets EPA protocols
for collection of ambient volatile
organic compunds (VOC) ensuring long
term sample stability, even in the ppb
range. A 6 liter canister can be set for
flow rates of 2 up to 500 scc/min to
facilitate short or lengthy sampling
times ande ease of operation.

5
Particulate Sampling

l o w n o i s e
Ve r y
High Volume PM 10 FH 95 Particulate Sampler
and PM 2.5 Samplers
The universal particulate sampler is
the initial stage for the manual
measurement of the particulate mass
concentration, the black carbon Highlights
content or the chemical laboratory
analysis for inorganic and organic  Easy setup, operation and
substances contained in the particles. calibration.
Manual sampling with gravimetric  Accurate pressure and temperature
evaluation (balancing) is used as measurement.
reference method to calibrate diffe-
rent particulate monitors. The FH 95  Selectable thresholds for minimum
uses the same sophisticated air flow air flow.
measurement and control like the  Multi interval sampling.
ESM Particulate Monitors. Therefore
no errors due to a variation of the air  Time-saving filter exchange by
flow rate in the sampling system slider mechanism.
occur.  Suitable for different filter types.


5 versioilnasblae re
Multi language operation menue.
 Storage of the last 10
measurements.
ava  Recording of power failures.
FH 95 E Particulate  Parameter and data memory.
Sampler - PM 2.5 µm  Automatic diagnostic with advanced
3
(1 m /h) US EPA reference microprocessor technology.
measurement (FRM),  Quality assurance with internal
EPA-Designation No. RFPS-1098-123 checkups and logbook feature.
Filter Exchange Mechanism for round
filter ( 47.8 mm)  Remote control possible.

For accurate sampling of airborne  Battery buffered memory and real-


particulates, the PM 10 High Volume
FH 95 E Particulate time clock.
Air Sampler is an EN 12341 Sampler - PM 10 µm (1 m3/h)  Selectable analog data output.
Reference Sampler for the
measurement of PM 10 in ambient air. FH 95 E - TSP -  Easy cleaning of the EPA WINS
PM 10 Size Selective High Volume Air Particulate Sampler (1 m3/h) 2.5 µm inlet.
Sampling Systems are available with  Automated leakage test.
either mass flow or volumetric flow FH 95 K (2.6 m3/h) TSP -
controllers, and with either brush or Reference Particulate Sampler
brushless motors.
The High Volume Sampler is also Small Filter Device, according to
available with a PM 2.5 imlet. VDI 2463, Part 8

FH 95 K (2.3 m3/h) PM 10 -
Reference Particulate Sampler
Small Filter Device (2.3 m3/h) with
LVS-PM 10-European reference
method, 220 V/50 Hz, inlet according
to EN 12341 Annex B1

6
The airflow is then split equally into
Sequential Particulate PM2.5 Speciation Monitor two 24 liter per minute AIHL cyclones.
Sampler FH 95 SEQ Features and Operation The cyclones remove particles larger
than 2.5 micrometers aerodynamic
The Sequential Particulate Sampler The RAAS2.5 Fine Particulate diameter.
FH 95 SEQ is designed for the manual Chemical Speciciation Sampler is Each of the two airstreams enters a
gravimetric mass concentration particularly useful for emission manifold which directs the air into a
determination of suspended particulate inventories, air quality mdel maximum of three separate and
in the ambient air or at working places evaluation, source emission analysis distinct flow paths. The sum of the flow
(indoor). and determining the success of rates for each manifold must total 24
The sampled particulate mass is emission control programs. The liters per minute. Individual flow rates
determined by balancing the filter RAAS2.5-400 quantifies mass are selectable for each manifold and
before and after sampling. The concentrations and simultaneously external filter samplers as for example
sampled particulate mass sufficient to identifies significant fine particle dichotomous samplers.
do chemical or radioactivity analyses. constituents including trace elements,
sulfates, nitrates, ammonium, carbon The RAAS2.5-400 utilizes the proven
The capacity with 16 filter cassettes and other tergeted species important to microprocessor-based, menu driven
stacked in a magazine allow an loal and regional issues. control and data recording system
automated and accurate filter change. common to the entire family of FRM
At 24 hour samples the stand alone Operation RAAS series samplers. The RAAS2.5-
operation time is 16 days or 14 days 400 monitors and records ambient,
(working with 2 empty filters). All RAAS2.5-400 components in manifold and enclosure temperatures,
contact with the sample air stream are barometric and pump vacuum
The FH 95 SEQ Sampler has a either PTFE or glass lined. Each pressures, humidity, optional wind
pressure and temperature compensated sample collection flow path is speed, wind direction and flow rates
probe to allow a precise measuring of individually controlled by a critical for each individual channel.
the air flow rate at ambient and orifice downstream of the collection
standard conditions. The air flow rate components. Ambient air is drawn into Leak checks and flow audits can be
(1 m3/h) is controlled by a rpm carbon the RAAS2.5-400 through an omni performed at the main sample inlet
vane pump at a stability of about 1%. directional, wind speed insensitive and upstream of each sample
inlet. 48 liters per minute of sample collection stream. A standard
Sequential Particulate Sampler air is pulled into the system and RAAS2.5 calibration kit accomplishes
FH 95 SEQ (2.3 m3/h) with EU-PM- maintained at ambient temperature. calibration and audit requirements.
10-small filter (LVS) device inlet.
Low Volume Sampler (LVS) with 16
filter cassettes.
Reference Sampler to the specification
of norm EN12341 at 2.3 m3/h

1. 2/2 valve for leakage test

2. Air flow regulation with


(RPM) speed regulated pump

Sampler output data:


Total volume (m3)
Standard volume (Nm3)
Average air flow (l/min)
Sigma (%) of the flow rate

7
ESM Inlets for Health Related
Sampling

The fraction of airborne particles


which is inhaled into a human body TSP - PM 10 - PM 2.5 -
depends on the properties of particles European PM-10 Reference Inlet
and the particle size. Inhaled particles
can be deposited somewhere in the ESM Andersen Instruments provides With special surface protection using
lung. They can cause damages close to size selctive inlets which can be an aluminium EMATAL surface,
the deposition site if the are corrosive, connected to all FH Sampling devices with special water separator and easy
carcinogenic, very small or capable of to fulfill the needs of health related exchangeable impactor baffle plate.
initiating some other type of damage. sampling. All inlets are designed for an
air flow rate of 1 m3/h (operational
ISO 7708 describes the particle size flow). The ESM monitors provide an
fraction definitions to be used for airflow control to operational
health-related sampling. conditions, therefore a stable cutpoint
and a stable measurement of a specific
health-related size fraction is achieved.
Size Selective Inlets
PM 10 ESM
They define the sampled particle size.
Air is drawn through these inlets in The PM 10 sampling inlet for
order to remove particles which exceed measuring the thoracic fraction of the
a specific aerodynamic diameter before suspended particulate (SPM) with an
exposing the filter to the air stream. aerodynamic diameter < 10 µm. DPM252301DP
Inlets are charcterized by sampling European PM 10 TÜV-Test Report PM 2.5 nozzle plate for a change of a
effectiveness curves. The curves are according EN 12341. DPM-10/2.3/01 into a PM 2.5 inlet
summarized by their 50% cutpoint DPM 2.5/2.3/01.
size, where half of the particles of that
size pass through the inlet and the DPM1010100PP
other half is deposited in the inlet.
Spare baffle plate (exchangeable).

Heated Sampling Tubes


The automatic measurement can be
100
disturbed by water condensation in the
sampling tube at foggy weather or high
Percentage of total airborne particles in convention

80
Healthy
adult
Inhalable convention absolute humidity in the summer. In
respirable
60
convention ESM heated sampling tubes the air
and particle temperature increases
40 smoothly over the complete tube length
’High risk’ Thoracic convention
respirable up to 2.5 m without overheating.
convention
20
DPM102301 Therefore a loss of
volatile components like
0
0 2 3 4 5 7 10 20 30 40 50 70 100
LVS-PM-10 reference sampling inlet ammonium salts (which
Aerodynamic diameter µm (2.3 m3/h) according to the European are converted in the
The inhalable, thoracic and respirable guideline EN 12341. gaseous phase above
conventions as percentages of total airborne
particles.
This EN reference method has to be 40 °C) is prevented.
used for quality check of all
PM 10 sample systems. These heatings can be
used in combination
with the ESM sampling
DPM1010100 inlets and the FH 62
PM 10 size selective inlet (1 m3/h) for monitors.
FH 62 Dust Monitors. Temperature selection
Same construction as the EN reference via operation menu or
inlet, but with 1 m3/h. interface.

8
MIE Optical Real Time
Monitors
12

10

personal DataRAM 1000

d50 (µm)
6

without Pump, Motor, Valves


– no Maintenance 4
– Mobile or Stationary
2
With a measurement range from 0.001
to 400 mg/m3 (auto-ranging), an
optically feedback-stabilized sensing 0 2 4 6 8
Flow Rate (liters/minute)
system, ultra-low power consumption
(negligible internal heating), and rigid with sharp, well defined particle
all-metal construction, the direct personal DataRAM 1200 separation characteristics. By
reading personal aerosol monitor operating the pump at specific
personalDataRAM sets the standards for Active Air Sampling and sampling flow rates, the pDR-1200
for sensitivity, long-term stability, and Aerodynamic Sizing cyclone preseparator provides precisely
reliability. These capabilities allow its defined particle size cuts.
use in many applications where such Designed for Size Selective
compact monitors were previously Particulate Monitoring Applications.
considered unsuited.
The personalDataRAM pDR-1200 is a
Extremely Compact and small, versatile, real-time aerosol
Rugged Design monitor for active sampling
applications. The pDR-1200 uses a
Palm-sized, the pDR 1000 weighs only pump module (pDR-PU) or other
0.5 kg (18 oz) and can be attached to sampling pump to perform particle
a belt or a shoulder strap, hand held, size selective measurements. Compact,
operated on a table top, or mounted on lightweight, and easy to use, it is ideal
a tripod. for respirable, thoracic, and PM 2.5
monitoring, as well as continuous
The personalDataRAM's rugged, yet emission and test chamber monitoring.
attractive, brushed extruded aluminum With an isokinetic sampling set, the
case is designed to protect the unit's pDR-1200 can be applied to stack and
optics and elecronics in even the duct extractive sampling/monitoring.
hashest industrial environments. With optional inlet accessories, the
pDR-1200 can also be used for
ambient air measurements under
Passive Air Sampling is variable wind and high humidity
Silent, Reliable And Economic.
conditions.
Air surrounding the monitor circulates
The pDR-1200 provides all the
freely through the open sensing
exceptional performance, advanced
chamber by natural convection,
features, and ease of use of the
diffusion, and background air motion.
following original personalDataRAM.
With this passive nephelometric
It offers unmatched measurement
sampling method, concentration
precision and stability, data logging
measurements do not depend on the air
and output versatility, ease of
velocity through the sensing chamber.
programming (using a PC and included
software), rugged design, and
exceptionally low power consumption.

The real-time aerosol monitor


incorporates an optimally designed
metal cyclone (BGI Model GK 2.05)

9
Black Carbon
and Stack

The Aethalometer
Real Time Aerosol Analyzing
The Aethalometer from Andersen
measures the "black" or "elemental" from outages and
carbon component of aerosols in pre-sents data
ambient air, indoor and occupational directly as BC
environments. This spezies is a tracer concentration in µg/
for combustion emissions and is a m3.
major component of PM 2.5 in urban
areas. The self-contained instrument is
designed for automatic, unattended Analytical
monitoring in environments ranging Performance
from urban settings to remote
locations. No consumables are required The Aethalometer
other than a roll of quartz fiber tape, can detect an increment of less than 1 concentrations of 5 to 25 ug/m3. Time
average one roll per year. nanogram of BC on the filter. At a flow base and air flow rate may be varied
The Aethalometer is based on two rate of 4 SLPM and a time base of ten by the user to optimize sensitivity
decades of experience in the minutes, this corresponds to a versus tabe use, with temporal
measurement of optically-absorbing resolution of 0.025 ug/m3, to be resolution selectable from 1 hour down
aerosols, with hundreds of predecessor compared with typical urban BC to 2 seconds.
units installed worldwide. Numerous
independent field studies have validated
the Aethalomter calibration against
standard chemical analysis.
The unique aspect of the instrument's
Operation Principle M 9096 "Mini" Stack operation is the flow control system
Sampler which maintains a fixed flowrate
The Aethalometer collects the aerosol through the system against increasing
on a quartz fiber tape and measures The Andersen M 9096 Stack Train is a pressure drop as the filter collects the
the optical absorption continuously revolutionary approach for low cost, particulate. This improves the accuracy
while the aerosol spot accumulates. manual isokinetic sampling for of the overall isokinetic flow measure-
Since "elemental" or "black" carbon is particulate. ment.
the dominant optically absorbing
species in the atmosphere, the spot This easy-to-use system
blackness may be equated to a mass of fully complies with the
BC according to calibration performed requirements of ISO 9096,
by intercomparisons with standard and BS 3405, and is self-
chemical analysis techniques. The rate contained in a lightweight
of increase of optical absorption is due weatherproof carrying
to the mass of BC collected per time case. The M 9096
base period, user selected from 2 consists of a 47 mm in-
seconds to 1 hour; combined with the stack filter in various
air flow rated measured by the mass configurations, extendible
flow meter. Sample collection proceeds modular probe assembly,
on a 1 cm3 spot until a threshold optional temperature/
optical density is reached, at which pressure or velocity
time the tape automatically advances. meters, integral pump
The optical measurement is radiometric and dry gas meter, drying
and no external calibration materials handle and a selection of
are required; filter tape is the only nozzles. All components
material used. The instrument runs prior to filtration are
automatically from power-up, recovers 316 stainless steel.

10
Andersen Impactors

Mark III In-Stack Cascade


Impactor
Andersen Mark III Stack Sampling
fractionation ranges from 10.0 to 0.4
Head is designed to operate with Eight Stage Non-Viable micrometers diameter. Particles too
existing stack trains containing the
"EPA type" pitobe with only minor
Impactor small to be impacted on the last
modification to the pitobe. collection plate are collected in the
Andersen Eight Stage Cascade backup filter.
Fractionating particles
Impactor is a multi-stage, multi-
aerodynamically in-stack provides
orifice sampler designed to measure
information that is not available with
other samplers. Such information
the size distribution and mass Features
concentration leves of solid
includes particle behavior after leaving  Samples wet or dry particulates.
particulates and liquid aerosols
the stack, area of environmental
directly. Empirically proven with  Gravimetric analysis allows
deposition, probable point of
over thirty years of data, only the reference method precision.
respiratory deposition, type of control
flowrate of Anderson Cascade
equipment required to collect particles  Ease of operation and calibration.
Impactors needs to be verified to
and efficiency of existing control  Particle bounce and wall losses
provide "calibrated performance".
equipment. virtually eliminated.
Andersen cascade impactors are  High mass collection and high flow
made up of classification stages rate.
consisting of a series of jets and
 Gravimetric or chemical sample
impaction surfaces. At each stage,
analysis.
an aerosol stream passes through
the jets and impacts upon the  Stainless steel, glass or filter
surface. Particles in the aerosol substrates available.
stream with a large enough inertia
will settle upon the impaction plate,
smaller particles passing as aerosol
In-Stack Cascade Cyclone into the next jet stage. By designing
Samplers stages with higher aerosol jet
velocities, smaller diameter
The Andersen In-Stack Cascade particles are collected at each stage.
Cyclone Samplers are in-stack, multi-
stage cyclones which easily attach to The particle size range collected at
EPA Method 5 or other stack sampling each of the eight stages depends on
probes and measure the complete size the je orifice velocity of the specific
distibution of particulate emissions. stage, the distance between the
orifices and characteristics of the
The CASE-PM 10 and CASE-PM 2.5 preceding stage.
are used to determine particulate
emissions at 10 and 2.5 microns by US The combination of a constant flow
EPA Method 201A (PM 10) and the rate and successively smaller
Draft Method for PM 10 and PM 2.5. diameter orifices increase the
This method applies to the velocity of sample air as it cascades
measurement of particulate matter at through the sampler, resulting in the
an aerodynamic size of 10 or 2.5 impaction of progressively smaller
microns by using in-stack cyclones particles in the succeeding stages.
operated at a constant flow rate. At 28.3 lpm the particle
Samples are separated by the cyclones
and collected on a preweighed filter
media.

11
Andersen Impactors and Cyclones

Marple 290 Personal Viable (Microbial) Samplers Features


Cascade Impactor  NIOSH report confirms Andersen
Microbiological content of air has
Viable Impactors are most
The Andersen Marple 290 Personal become a significant environmental
accurate microbial samplers.
Cascade Impactor is the first precision concern as the need for
 Low initial cost.
cascade impactor worn by the worker "contamination-free" air increases.
Viable particulate samplers are used to  Simple operation.
giving complete, accurate aerodynamic
particle size distribution. Rugged collect airborne bacteria and fungi.  Easy calibration.
Series 290 impactors are compact and There are two constraints on all viable  Can be completely sanitized.
lightweight with Andersen's patented particle samplers: the particle must be  Based on the inertial impaction
radial slot design, widely acclaimed for separated from the air, and the ability principle, therefore very "sharp
accuracy, minimal internal losses and of the particle to reproduce must be cuts".
absence of particle bounce. maintained. Andersen impactors  CFUs (colony forming units) easily
satisfy these constraints and have been determined.
proven to be the most effcient for  Only Andersen viable sampler have
collection of bioaerosols. verifiable flow rate (28.3 lpm).
 Flow rate does not jeopardize
The collection and assessment of collected organisms.
aerosol samples is very simple. A petri
 Inlet Cones are Easy to Calibrate
dish containing an agar medium
and Give a More Representative
appropriate for the microorganisms
Sample
which may be encountered is placed in
the instrument and a sample of air is
drawn. The petri dish is then removed, Microbial Sampling
incubated, and counted by an accepted Applications
method.
 Indoor air quality studies.
Available as 1, 2 or 6 stage version.  Pharmaceutical production.
 Animal care laboratories.
 Wastewater treatment plants.
 Cosmetic manufacturing.
 Filter and clean room efficiency
studies.
 Brewery fermentation.
 Food processing area.
 Hospital environments.
 Grain processing and
transportation.
 Agricultural emissions.

Environmental Monitoring
ESM Andersen Instruments

ESM Andersen Instruments GmbH


Please visit our
Frauenauracher Strasse 96 website
D-91056 Erlangen / Germany
3/6/00 · Subject to changes

www.esm-
Phone: +49 91 31 909-202 online.de/
Fax: +49 91 31 909-156 andersen/
eMail: esm.andersen@esm-online.de
Internet: www.esm-online.de/andersen/
Postal address: P.O.B 1660 · D-91051 Erlangen / Germany

A Thermo Instrument Systems Company

Das könnte Ihnen auch gefallen