Fill Placement Inspection

SAES-A-114
A1 Fill material shall be placed in lifts not exceeding 200mm in loose depth.
Sec. 6.3.2.2

Fill material shall be placed in lifts not exceeding 100mm in loose depth SAES-A-114
A2
for hand-operated compaction. Sec. 6.3.2.2

Other lift thicknesses shall be allowed with approval by the Saudi


SAES-A-114
A3 Aramco Inspector based on a field test of the method, equipment and
Sec. 6.3.2.2
materials involved.

Fill and backfill adjacent to any type of structure shall not be compacted
SAES-A-114
A4 with heavy equipment; Hand operated equipment shall be used within
Sec. 6.3.2.3
1.2 meters of any structures.

Every effort shall be made to place backfill materials symmetrically and


SAES-A-114
A5 in uniform layers to prevent unnecessary eccentric loading on a structure
Sec. 6.3.2.3
or foundation.

Compacted surfaces of fill and backfill shall be finish graded to the cross SAES-A-114
A6
sections, lines, grades and elevations as indicated on the drawings. Sec. 6.3.2.11

Backfilling and removal of trench supports shall be accomplished by


backfilling up to a level allowing for removal of the lower braces; Another SACSM
A7
layer of backfill shall then be positioned in the trench to the next layer of Sec. 2.9
braces to be removed.

Removal of trench supports or shoring shall progress together with the


SACSM
A8 backfill from the bottom of the trench; In unstable soil, ropes shall be
Sec. 2.9
used to pull supporting materials from the trench.

B Compaction Inspection

Compaction shall begin only after the fill or backfill has been properly
placed and the material to be compacted is at the proper moisture SAES-A-114
B1
content. +/- 3% of the optimum moisture content per ASTM D1557 or Sec. 6.3.2.7
ASTM D698, whichever is applicable. (PIP-CVS02100, Sec. 4.3.2.3)
SAES-A-114
B2 Compaction shall be performed with equipment compatible with soil type.
Sec. 6.3.2.1

Fill or backfill placed beneath footings, grade beams, mats, buildings or


SAES-A-114
B3 process areas shall be compacted to at least 90% of the maximum
Sec. 6.3.2.5
Modified Proctor density as determined by ASTM D1557.
For cohesionless free draining soils, 70% relative density as determined
SAES-A-114
B4 by ASTM D4253 and ASTM D4254 shall be achieved under footings,
Sec. 6.3.2.5
grade beams, mats, buildings or process areas.

Page 1 of 2
SAUDI ARAMCO ID/PID - 18-MAY-05 - REV 0 (Standards Cutoff - August 2004)
SAIC NUMBER DATE APPROVED QR NUMBER
SAUDI ARAMCO INSPECTION CHECKLIST
Fill Placement and Compaction Inspection SAIC-A-1004 18-May-05 CIVIL-
PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.

Under foundations with static loads over 320kPa and foundations for
vibrating or heavy machinery and pavements, 85% of relative density SAES-A-114
B5
(ASTM D4253/ASTM D4254) for cohesionless soils or 95% of of the Sec. 6.3.2.5
maximum density as determined by ASTM D1557 for cohesive materials.

When the backfill material cannot clearly be classified as cohesive or


cohesionless both relative density and Proctor density tests must be SAES-A-114
B6
performed per the above paragraph. The backfill shall then be Sec. 6.3.2.5
compacted to the greater density.

Compaction by water jetting is not permitted; Flooding may be used if the SAES-A-114
B7
material is cohesionless freely draining sand. Sec. 6.3.2.8

In no case shall compaction be allowed on slopes greater than 1 to 5; A


SAES-A-114
B8 series of horizontal benches, steps, or terraces, at least 3 meters wide
Sec. 6.3.2.9
should be constructed and compacted instead.

Construction of new slopes shall be accomplished by compacting


SAES-A-114
B9 horizontal fill layers at least 1 roller width beyond the design edge of the
Sec. 6.3.2.9
slope then trimming back to achieve the final slope dimensions.

Compacted surfaces of fill and backfill shall be finish graded to the cross SAES-A-114
B10
sections, lines, grades and elevations as indicated on the drawings. Sec. 6.3.2.11

REMARKS:

REFERENCE DOCUMENTS:
1- SAES-A-114 -- Excavation and Backfill, 28 April 2004
2- SACSM -- Saudi Aramco Construction Safety Manual, February 1993

Contractor / Third-Party Saudi Aramco


Construction Representative* PMT Representative
Work is Complete and Ready for Inspection: T&I Witnessed QC Record Reviewed Work Verified
Name, Initials and Date: Name, Initials and Date:

QC Inspector PID Representative


Performed Inspection Work / Rework May Proceed T&I Witnessed QC Record Reviewed Work Verified
Name, Initials and Date: Name, Initials and Date:

QC Supervisor Proponent and Others


Quality Record Approved: T&I Witnessed QC Record Reviewed Work Verified
Name, Organization,
Name, Sign and Date:
Initials and Date:

*Person Responsible for Completion of Quality Work / Test Y = YES N = NO F = FAILED