Sie sind auf Seite 1von 1

Test on Anchorage System

Test Method: BS 4447:1973


PRO-POOR EASTERN INFRASTRUCTURE DEVELOPMENT PROJECT
Contract Package - 03
Contractor Consultant Employer
State Development and Construction Corporation Oriental Consultant Ltd, Road Development Authority
Nippon Koei Company Ltd
Engineering Consultants Ltd

To be filled when Casting

Test No:- 951/MLR/ANC/03

Casting Date- 25.02.2011 Time- 15.34 hrs

Product/ Structure : Strength Category Ref. Mix Design Code

Kallady Bridge - Anchor Cone Grade. 50 TM- 31 B


Testing

Storing Curing Method of Compaction Place

Laboratory curing tank Water Hand Tamping Rod Project Lab

Specimen Nos. 1 1 1
.
To be filled when Crushing

Specimen No. 1 1 1

Date & Time of Testing 04.03.2011 @ 3.50pm 04.03.2011 @ 3.50pm 04.03.2011 @ 3.50pm

Specimen Age (days) 5 5 5

Length (mm) 270 270 270

Breadth (mm) 270 270 270

Height (mm) 300 300 300


Average Concrete Compressive
2
Strength at Testing (N/mm )
Use of Wedges on Bearing Plate Used Used Used

Maximum Load (kN) 2059.8 2059.8 2059.8

Mode of Failure of Anchorage System Not failed Not failed Not failed
Load at Crack Propagation Started on
Concrete(kN)
Specification: Minimum load at failure =1849.85kN
Remarks: Grade 50/20 concrete mix design for beam casting
Maximum agregate size is 18mm

Comments:

Contractor Date Consultant Date

Cast & Supplied by

Tested by

Checked by

Material Engineer