Sie sind auf Seite 1von 52

®

Transparencies ELABOTrainingsSysteme

LOGO!

Transparencies
Version 4.1 – Order No. E40 803

LOGO!
®

Transparencies ELABOTrainingsSysteme

Safety Note

Attention!

Please follow all the necessary safety regula-


tions, laboratory rules and take the necessary
safety precautions when setting up and testing
the systems!

Copyright © ELABOTrainingsSysteme GmbH


Aus- und Weiterbildung
Im Hüttental 11
85125 Kinding
Germany

LOGO! 2
®

Transparencies ELABOTrainingsSysteme

Source specification
Siemens LOGO! Manual ASE 00 228 104-01
Siemens Software LOGO! Soft-Comfort V4.0
The LOGO! manual and the Help for LOGO! Soft-Comfort contain all the details
necessary for working with LOGO!. They therefore provide useful advice for pro-
gramming and operating LOGO!.

Warning: Important Notes


Warning for the variants LOGO! 230RC, 230RCo and extension module
LOGO! 230R DM8.

Dangerous voltage!
Dont’t put your fingers or any object into the slot for
the program mudule. If the power supply is not con-
nected correctly, the plug for the program module
may be carrying the supply voltage.

Remedies:
Connect L1 to only one phase and N always to the neutral conductor. Connect the
inputs to the same phase as the power supply.
The slot for the program module must always be connected in operation. If you
don’t plug in a program module, connect the slot to the cover.

Please follow the safety instructions in the Siemens LOGO! manual!

LOGO! 3
®

Transparencies ELABOTrainingsSysteme

Table of contents

LOGO! 5
Areas of application and advantages of LOGO! 6
Connections, Input − Output 7
Connect LOGO! 8
Important terms 9
Abbreviations used 10
Basic functions (BF) 11
Special functions (SF) 12 - 15
Conversion circuit diagram − LOGO! program 16
Input and output boxes 17
Programming rules 18
Program an wiring 19
Entering the program 20
Parameterizing LOGO! 21
The integrated clock 22
Link LOGO! − PC 23
The LOGO! Soft-Comfort Software 24
Program editing with LOGO! Soft Comfort 25

LOGO! 4
®

Legend ELABOTrainingsSysteme

LOGO!

What is LOGO! ?
3 A universally applicable logic module for electrical
engineering.

3 LOGO! bridges the gap between conventional


wiring techniques and micro-PLC.

3 Use for solving minor control problems.


3 Designed for mounting on a 35 mm top hat rail.
3 Space requirement 4 DU (72 x 90 x 55 mm)
3 Contains: - Control
- 14 practical functions
- Control unit
- Aight inputs
- Four outputs
- Display unit

3 „Wiring“ at the press of a button.

LOGO! 5L
®

Legend ELABOTrainingsSysteme

Areas of application and


advantages of LOGO!
Examples of applications:
3 Stairway lighting
3 Outdoor lighting
3 Shutter control
3 Sunshade control
3 Conservatory control
3 Holiday automatic control for apartments
3 Gate control
3 Ventilation system control
3 Water pumps

Concrete advantages
3 Universal due to the integration of various components
such as surge relays, automatic stairway lighting control,
switch-off delay, etc.
3 A smaller distributor box may possible be used
(e.g. 1 LOGO! instead of 2 surge relays, 1 clock,
1 automatic stairway lighting control).
3 No rewiring is necessary for modifications.
3 The program can also be edited an a PC.

LOGO! 6L
®

Legend ELABOTrainingsSysteme

Connections, Input − Output

Power supply terminals:


to connect the power supply.
Two varaints are available for LOGO!-Basic:
- Class 1 < 24 V, d.h. 12 V DC, 24 V AC
- Class 2 > 24 V, d.h. 115...240 V AC/DC
8 digital inputs:
Connection possibility for pushbutton switches, switches,
sensors ...
Interface for program modules or PC cables:
If there is a program in the control unit, this is stored safe
from power failure in the EEPROM.
Programs can be read in and out optionally by using pro-
gram modules.
Connection to a computer is possibly by a PC cable.
Key control panel:
6 control keys for program input or parameterization.
4 digital outputs:
Connection facility for 4 consumers. The load current may
be up to 10 A on ohmic load.
LCD display panel:
Every function is displayed as a function diagram when pro-
gramming. The states of the inputs and outputs are desplay-
ed during operation.

LOGO! 7L
®

Legend ELABOTrainingsSysteme

Connecting LOGO!

Note:
Different versions of LOGO! are available!
See the LOGO manual for information on these.
In all the following considerations we refer to the AC voltage
version with clock LOGO! 230 RC.
Power supply:
The mains voltage is connected at L1 an N.
Its value may be between 85 V and 253 V. The current con-
sumption is 20 mA at 240 V (equivalent to 1 kWh/week).
The unit has protective insulation.
Inputs:
The switching equipment or sensors are connected directly
to the inputs I1 ... I8.
At voltage values < 40 V AC LOGO! recognize the „open“
switch state, at values > 79 V AC the „closed“ switching
state.
Outputs:
The loads such as lamps, motors, contactors etc. can be
connected directly to the outputs Q1 ... Q4 providing the
switching current does not exceed 10 A on ohmic load (3 A
on inductive load).
the outputs are potential-isolated relay contacts.
The load is fused with a circuit breaker < 16 A, charakteristic
B16.

LOGO! 8L
®

Legend ELABOTrainingsSysteme

Important terms

Terminals:
Terminals are used to designate connections (inputs and
outputs in the program).
Terminals may also be whole circuit parts (blocks) or fixed
states.
Functions:
LOGO! has a number of permanently installed functions. A
distinction is made between:
- Basic functions
- Special functions
Basic functions are simple links such as AND.
Special functions are for example surge relays or clock.
Blocks:
Blocks are functions switched by terminals.
Every time a block is inserted in a program, LOGO! automa-
tically assigns a block number.
The connection of blocks is displayed in the program by
these block numbers.
The block number appears in the top right of the display.

LOGO! 9L
®

Legend ELABOTrainingsSysteme

Abbreviations used
AM with the analog module can be changed analog values over 2
analog inputs
B1 appears in the top right of the display or at the input of
another block
BN appears at the input of a block if a new block is to be insert
C this devices name stands by LOGO! for integrated clock
CM with the communication module the LOGO! can be wiring
with a bus system (e.g. AS interface)
Cnt the switching process are counted here
Co here it is selected whether this is an input or an output,
an unwired input or a defined state (high or low).
Dir Dir = 0: counting direction forwards
Dir = 1: counting direction backwards
En the clock generator is switched on and off with En
Fre evaluated frequency singals will be connected on the
inputs with this names
GF the basic functions can be selected here
hi an output is set permanently to high potential
Inv the output signal of the block will be inverted if the
input head for
Io an input is set permanently to low potential
No every clock has three cams, the switch on and switch
off points are set at No
P this input is not of set. Here you have to set prioritys, whether
a message in RUN mode has be confirmed.
Par setting of the internal counting value
R reset a special function (e.g. counter)
Ral all intern values are setting back
S set the selb-hold relay
SF the special functions can be selected here
T parameter in time setting (e.g. switch off delay)
Ta current value of a time is displayed during parameterization
Trg the delay time is started for exmaple at the trigger input
x unwired inputs must be occupied by „x“

LOGO! 10L
®

Legend ELABOTrainingsSysteme

Basic functions (BF)

AND:
The output of the AND only adopts state 1 when all three
inputs have state 1.
For AND applies: x = 1.
NAND:
The output of the NAND only has state 0 when all three
inputs have state 1.
For the NAND it applies: x = 1.
OR:
The output of the OR always adopts the 1 state when at
least one of the three inputs has state 1.
For OR it applies: X = 0.
NOR:
The output of the NOR only has state 1 when all three
inputs have state 0.
For the NOR it applies: x = 0.
NOT:
The output of the NOT adopts the 1 state when the input
has state 0 and vice versa.
For NOT it applies: X = 1.

LOGO! 11L1
®

Legend ELABOTrainingsSysteme

XOR:
The output of the XOR adopts the 1 state when the inputs
have different states.
For the XOR it applies: x = 0.
AND with flanks evaluation:
The output of the AND with flanks evaluation adopts the 1
state when all inputs have state 1 and inside previous cycle
at least one input had the condition 0. The output will be
stay of the 1 state for a cycle and must have the 0 state for
a cycle, before er adopts the 1 state again.
For the AND with flanks evaluation it applies: x = 1.
NAND with flanks evaluation:
The output of the NAND with flanks evaluation adopts the 1
state when all inputs have state 0 and inside previous cycle
at least one input had the condition 1. The output will be
stay of the 0 state for a cycle and must have the 1 state for
a cycle, before er adopts the 0 state again.
For the AND with flanks evaluation it applies: x = 1.

LOGO! 11L2
®

Legend ELABOTrainingsSysteme

Special functions (SF): Time

Switch on delay:
The output of switch on delay adopts after a special time.
Switch off delay:
The output of switch off delay is setting back after a special
time.
Switch on/off delay:
The output of siwtch on/off delay adopts after a special time
and is setting back after a special time.
Stored switch on delay:
The output of stored switch on delay adopts a special time
after a input impuls.
Wisp relay:
An input signal creats a output signal after a special time.
Flanks triggerd wisp relay:
An input signal creats a output signal after a special time.

LOGO! 12L1
®

Legend ELABOTrainingsSysteme

Asynchron digit emitter:


The pulse envelope of the exit let’s herself on that parame-
trierbare impulse-/breaks ratio manipulate.
Random generator:
the output of random generator is setting after a parametrized
time.
Stairwaylighting switch:
After an input impuls run a time.
Comfort switch:
Switch with two functions:
- Impulse switch with switch off delay
- Switch
Week switch clock:
The output becoming on a parameterable switch on and
switch off date steered. Any possible combination of days
becoming supports.
Year switch clock:
The output becoming on a parameterable switch on and
switch off date steered.

LOGO! 12L2
®

Legend ELABOTrainingsSysteme

Special functions (SF): Counters

Forward and backward counter:


Ever after parametrization becoming by a input pulse a inter-
nal counter value high or down counted. Bey reach the para-
meterable threshold becoming the exit sat resp. put back.
The count direction can using the entrance you manipulating
will be.
Running hours counter:
If the supervision entrance sat becoming, runs a parametera-
ble time ex. The exit becoming sat, if the time expired is.
Threshold counter:
The exit becoming as a function of two parameterable fre-
quencies switched on and switched off.

LOGO! 13L
®

Legend ELABOTrainingsSysteme

Special functions (SF): Analog

Analog threshold switch:


The output becoming as a function of two parameterable thre-
sold value switched on and switched off (backlash).
Analog different threshold switch:
The output becoming as a function of a parameterable thres-
hold and difference value switched on and switched off.
Analog comparator:
The output becoming as a function of the difference Ax - Ay
and of two parameterable threshold values sitched on and
switched off.
Analog value supervision:
This special function stores a on analog output fitting value
and switches the exit, as soon as the actual value on analog
input these stored analog value plus ones parameterable dif-
ference of the value under- or crosses.
Analog amplifier:
this special function amplfy on analog input a signal and give
it up to the output.

LOGO! 14L
®

Legend ELABOTrainingsSysteme

Special functions (SF): Other

Self holding relay:


Via input S becoming the output Q sat. Via other input R
becoming the output again put back.
Impulse relay:
That setting and resetting of the output becoming at a time by
a short impulse for the input realizes.
Message text:
display of a message text in RUN mode.
Software switch:
This special function have the same effect like a mechanical
pushbutton e.g. switch.
Shift register:
With which function shift register are you able the value ones
of the input read out and bit by bit shift. The value of the exit
corresponds of the parameterable shift register bits. The shift
register can via special input manipulating.

LOGO! 15L
®

Legend ELABOTrainingsSysteme

Conversion circuit diagram −


LOGO! program

Solution in the circuit diagram


As is already obious from the set task, this is an OR link.
If S1 or S2 is actuated, current flow through the relay coil and
K1 pulls up.
This actuates its NOC and the lamp E1 lights.

Solution in LOGO!
The switch S1 is connected at terminal I1 of the LOGO!.
The switch S2 is connected at terminal I2 of the LOGO!.
Since only two inputs of the OR block are used, the third input
must be marked not used. The x at the input is used to do
this.
The output of the OR block controls the relay at the output
Q1. The consumer E1 is connected at the output Q1.

LOGO! 16L
®

Legend ELABOTrainingsSysteme

Input and output boxes

Key control panel:


The key control panel consists of six input keys. These can be
used to make all the necessary entries.
Cursor keys: Move the cursor in the program or the menu.
Select functions and terminals when program-
ming.
ESC key: One step back, exit program entry.
OK key: Accept input.
< - > - OK: Switch on programming mode.
ESC - OK: Switch on parameterization mode.

LOGO! display in RUN:


Switch on LOGO! in Run
Switch on LOGO! in RUN in the main menu.
1. Bakc in main menu: Key ESC
2. Move ‘>’ to ‘Start’: Key S or T
3. Select ‘Start’: Key OK
LOGO! starts the program and shows following display:

What means: „LOGO! is in RUN“?


Inside RUN works LOGO! that scolded program ex. To it read
LOGO! first of all the conditions the inputs, ascertains with the
for you stated scolded program the conditions the exits and
switch the exits a or out.

LOGO! 17L
®

Legend ELABOTrainingsSysteme

Programming rules
Rule 1:
You enter the circuit in the Programming mode. You got to the
programming mode by pressing the three keys <, > and OK at
the same time.
You change the values of times and parameters in the parame-
terization mode. You got to the parameterization mode by pres-
sing the 2 keys ESC and OK at the same time.
Rule 2:
You alwas enter a circuit:
From the output to the input.
Rule 3:
When entering a circuit the following applies:
If the cursor is displayed as an underscore you can move the
cursor
- with the keys <, >, or v you move the cursor in the
v
circuit.
- with OK you change to Select terminal/block.
- with ESC you exit the circuit input.
If the cursor is displayed as a full block you should select a
terminal/block
- with the keys or v you select a terminal/block.
v
- with OK you accept the selection.
- with ESC you go back one step.
Rule 4:
LOGO! can only store complete programs.

LOGO! 18L
®

Legend ELABOTrainingsSysteme

Program and wiring

The switches, pushbutton switches and sensors can be con-


nected to the LOGO! inputs I1 ... I8 in any order.

When entering the ptorgram make sure that the designa-


tions of the inputs are chosen to match the switch designa-
tions.

No different phases may be connected to the inputs.

the inputs of the output relays of LOGO! are wired with L1.

If an output is set in the program, this controls the appropri-


ate relay in the LOGO!.

LOGO! 19L
®

Legend ELABOTrainingsSysteme

Entering the program

1 First display in the program input is the output Q1 J OK.


2 Cursor jumps to the input because it is displayed as a
full block, function can be selected.
3 Press T and set BF (basic function) J OK.
4 AND is displayed as the first basic function.
5 Select OR with T and confirm with OK.
6 Cursor jumps to the first input of the OR block J OK.
7 Co for terminal at the first input J OK.
8 On input stands I1 J OK.
9 Cursor jumps to the second input of the OR block J OK.
10 Co re-appears J OK.
11 On input stands I1 J T.
12 On input stands I2 J OK.
13 Cursor jumps to the third input of the OR block J OK.
14 ESC switches back to edit menu.
15 ESC switches back to program menu.
16 ESC switches back to main menu.
17 Pressing T key for three times select Start, OK starts
the program.
18 Display in RUN mode.

LOGO! 20L
®

Legend ELABOTrainingsSysteme

Parameterizing LOGO!
Term:
Parameterizing can be understood as the setting of block
parameters.
Parameters can be set in the Programming mode and in the
Parameterization mode.
The user can change settings (such as delay times) in the
Parameterization mode without having to interrupt the run-
ning program.
RUN-Mode:
You can go to the Parameterization mode by pressing the
ESC key.
Parameterization menu:
The four menu items „Stop“ (stop switch program), „Set
Param“ (set parameters), „Set Clock“ (clock settings) and
„Prg Name“ (give a program name) are available in the para-
meterization menu.
Parameter display:
Parameters are marked by LOGO! by the block number (B9).
The display T = 60:00 s indicates that the delay time is set to
60 seconds.
The display Ta = 06:00 s shows the current value of the expi-
red time since the start of the delay time.

LOGO! 21L
®

Legend ELABOTrainingsSysteme

The integrated clock

The clock integrated in LOGO! has an hour/minute and a


weekday display.
The time can be set in the two operating modes
- Programming and
- Parameterization.

A program is running in the LOGO! (RUN):


The time can be set with Programming and Parameteri-
zation.

There is no program in the LOGO!:


The time is set in the Programming mode.

Set clock window:


The cursor can be moved in the window with the < and > keys
to select day, hour and minute.
The days, hours and minutes can be set with the and v keys.
v

LOGO! 22L
®

Legend ELABOTrainingsSysteme

Link LOGO! − PC

To be able to operate LOGO! with a PC the LOGO! PC


cable and the LOGO! Soft Comfort software are required.
The slot cover of the LOGO! is removed and the cable con-
nected.
A free serial interface is required on the PC.
Switching LOGO! into the PC Q LOGO! operating
mode:
1. Switch on LOGO! with/without display from the PC in
STOP (look at online-help of LOGO! Soft Comfort) or
choice with display ESC / >Stop and select there
‘Yes’.
During LOGO! is in STOP and connect with the PC
it will be understood following PC commands:
- Switch on LOGO! in RUN mode.
- Switch program read/write.
- Time, summertime/windertime write/read..
2. If you start the upload/download in STOP,
it appears the following display:

PC Q +.
+. = LOGO!

End operating mode PC Q LOGO!:


After the succesful data transfer will be end the connection to
the PC automatically.

LOGO! 23L
®

Legend ELABOTrainingsSysteme

The software LOGO! Soft Comfort

The foil shows the LOGO! Soft Comfort screen after starting
the program.
Program title bar:
Shows the name of the loaded program.
Menu bar:
Shows the seven available main menus:
- File
- Work
- Format
- View
- Extra
- Window
- Help
For beginning the programming, look that in the menu „Extra“
the right devices choice is selected.
Standard bar:
You can choice here neccessary menu points with symbols.
Tool bar:
You can select here the used tools.
Device choice bar:
You see here the used block.

LOGO! 24L
®

Legend ELABOTrainingsSysteme

Program editing with


LOGO! Soft Comfort

The example program PUMP.LGO is loaded. The description


and the circuit diagram can be found in the LOGO! manual on
page 255.
To test the program select „Simulation“ in the main menu
„Extras“. After this the sumulation bar shows switches and
lamps. The Switches or the inputs in the function diagram can
be selected with the mouse pointer so that the function of the
program can be tested.
The test mode is switched back off by the „Simulation“ item
in the „Extras“ main menu.
The program is transferred to LOGO! by selecting „Transfer
> PC J LOGO!“ in the „Extras“ main menu.
LOGO!Soft Comfort then reports successful transfer of the
program.

LOGO! 25L
®

Transparencies ELABOTrainingsSysteme

LOGO!

LOGO! 5
®

Transparencies ELABOTrainingsSysteme

Areas of application and


advantages of LOGO!

Areas of application
3 in hous and installation technology
3 in switch cabinet construction
3 in small machine and apparatus construction
3 for special control systems
3 for signal pre-processing for control systems

Advantages
3 universally applicable
3 saves space in the distributor box
3 simple operation on site
3 simple circuit input
3 reduced wiring expense
3 flexible modification possibilities
3 failsafe storage

LOGO! 6
®

Transparencies ELABOTrainingsSysteme

Connections,
input − output

Power supply
terminal 8 digital inputs

Interface for
program
module or
PC cables

LCD Key control


display panel

4 digital outputs

LOGO! 7
®

Transparencies ELABOTrainingsSysteme

Connecting LOGO!

L1
Power
supply N

Inputs L1
S1 S2

Outputs

L1 Load
F1 max. 16 A
N

LOGO! 8
®

Transparencies ELABOTrainingsSysteme

Important terms

Terminals
Inputs Outputs

Functions
Basic Special
functions functions

Blocks

The link between terminals and functions.

LOGO! 9
®

Transparencies ELABOTrainingsSysteme

Abbreviations used
AM Analog module
B1 Block number B1
BN Block number
C LOGO! devices name: integrated clock
CM Communication module
Cnt Count (input for counter)
Co Connector (terminal)
Dir Direction (count direction)
DM Digital module
En Enable
Fre Frequency signal
BF Basic function
hi High condition
I1 Input 1
Inv Invert
Io Low condition
No Nock
P Priority
Par Parameter for counter
Q1 Output 1
R Reset
Ral Reset all
S Set
SF Special function
T Time
Ta Actual value of time
Trg Trigger
x Unwiring input

LOGO! 10
®

Transparencies ELABOTrainingsSysteme

Basic function (BF)


Display Designation
LOGO!
B1
In1
In2 & AND
In3 Q1
In4

B1
In1
>1
In2
In3 Q1
OR
In4

B1
1
In Q1
NOT

B1
In1
In2 & NAND
In3 Q1
In4

B1
In1
>1
In2
In3 Q1
NOR
In4

B1
In1 =1
In2 Q1 XOR

Timing diagram:

B1
In1
In2 & AND with
In3 Q1 flanks
In4
evaluation
B1
In1
&L
NAND with
In2
In3 Q1 flanks
In4
evaluation

LOGO! 11
®

Transparencies ELABOTrainingsSysteme

Special functions (SF): time


Timing diagram Display Designation
LOGO!

B1
Trg
Par Q1 switch on delay

B1
Trg
R Q1
switch off delay
Par

B1
Trg switch on/off
Par Q1 delay

B1
Trg stored switch
R Q1
Par on delay

B1
Trg wisp relay
Par Q1

B1
Trg flanks triggerd
R Q1
Par wisp relay

LOGO! 12-1
®

Transparencies ELABOTrainingsSysteme

Timing diagram Display Designation


LOGO!
B1 asynchron digit
En
Inv Q1 emitter
Par

B1
En
random
Par Q1 generator

B1
Trg stairwaylighting
Par Q1
switch

B1
Trg comfort switch
R Q1
Par

B1
No1
week switch
No2
No3
Q1 clock

B1
MM year switch
No DD Q1
clock

LOGO! 12-2
®

Transparencies ELABOTrainingsSysteme

Special functions (SF): counter


Timing diagram Display Designation
LOGO!
B1
R
Cnt forward / back-
Dir +/- Q1
Par ward counter

B1
R running hours
En h
Ral Q1 counter
Par

B1
Fre threshold
Par Q1
counter

LOGO! 13
®

Transparencies ELABOTrainingsSysteme

Special functions (SF): Analog


Timing diagram Display Designation
LOGO!

B1
Ax A analog threshold
Par Q1
switch

B1
Ax A analog different
Par Q1
threshold switch

B1
Ax A analog
Ay
Par
Q1 comparator

B1
En A analog value
Ax + Q1
supervision
Par

B1
A analog amplifier
¾

Ax
(no timing diagram) Par AQ1

LOGO! 14
®

Transparencies ELABOTrainingsSysteme

Special functions (SF): other


Timing diagram Display Designation
LOGO!
B1
S RS self holding
R Q1
Par relay

B1
Trg
S
R Q1
impulse relay
Par RS

B1

(no timing diagram)


En message text
P Q1
Par

B1
En software switch
Par Q1

B1
In
Trg shift register
Dir Q1
Par

LOGO! 15
®

Transparencies ELABOTrainingsSysteme

Conversion Circuit Diagram −


LOGO! program
Problem:
The consumer E1 is switched on or off by the switches S1 or
S2. The relay K1 pulls up when S1 or S2 is closed.

Solution in the circuit diagram:

Solution with LOGO!:

equivalent to K1

Wiring Program Wiring

LOGO! 16
®

Transparencies ELABOTrainingsSysteme

Input and output boxes

Key control panel:

Cursor keys

Display of LOGO! in RUN:

Date and time

Key

Inputs I1 ... I9
Inputs I10 ... I19
Inputs I20 ... I24
Key

Outputs Q1 ... Q9
Outputs Q10 ... Q16

Key

Flags M1 ... M9
Flags M10 ... M19
Flags M20 ... M24
Key

4 cursor keys for manual


gear into that scolded pro-
gram (ESC + desired key)

LOGO! 17-1
®

Transparencies ELABOTrainingsSysteme

Programming rules

Prog. J OK Programming
Edit J OK
Edit Prg. J OK
mode „EIN“

from the output


Programming
to the input

Cursor as
Move cursor
underscore

Cursor aa full
enter
block

ESC one step back

OK Accept

LOGO! 18
®

Transparencies ELABOTrainingsSysteme

Program an wiring

Wiring Program Wiring

L1 N

LOGO! 19
®

Transparencies ELABOTrainingsSysteme

Entering the program


1 2 3

OK T OK
Q1  Co Q1  GF Q1

4 5 6
B1 B1 B1
In1 In1 In1
In2 _& T In2 >1 OK In2 >1 OK
In3 Q1 In3 Q1 In3 Q1
In4 In4 In4

7 8 9
B1 B1 B1
 Co OK I1 OK I1 OK
In2 >1 In2 >1 In2 >1
In3 Q1 In3 Q1 In3 Q1
In4 In4 In4

10 11 12
B1 B1 B1
I1 OK I1 T I1 OK
 Co >1 I1 >1 I2 >1
In3 Q1 In3 Q1 In3 Q1
In4 In4 In4

13 14 15
I1
B1
ESC >Edit Prg ESC >Edit ESC
I2 >1 Edit Name Clear Prg
In3 Q1
In4
Memory Password

16 17 18
3 mal
>Edit Edit
T OK
Clear Prg Clear Prg TU 15:35
Password Password 2004 - 09 - 01
Start >Start

LOGO! 20
®

Transparencies ELABOTrainingsSysteme

Parameterizing LOGO!

Change setting values


of special functions
during operation

Delay time Scolded swell


of a timing for an threshold
relay switches

Switching Threshold Machine attention time


times of a value of a for an operating hours
clock counter counter

RUN mode:
Mo 15:35
2004 - 09 - 01

Parameterization menu: >Stop


Set Param
Set Clock
Prg Name

Parameter display: B9 1
T =60:00s

Ta =06:00s
No parameter is changable:
With ESC back to main No Param
menu. Press ESC

LOGO! 21
®

Transparencies ELABOTrainingsSysteme

The integrated clock


Setting the time
Program running No program in LOGO!

Mo 15:35 No Param
2004 - 09 - 01 Press ESC

ESC ESC

>Stop >Program..
Set Param Card..
Set Clock Clock..
Prg Name Start

2 mal T 2 mal T

Stop Program..
Set Param Card..
>Set Clock >Clock..
Prg Name Start

OK

>Set Clock
S/W Time
Sync

Set Clock
Mo 15:30
yyyy-MM-DD
2003-01-27
set move
v <->
v

LOGO! 22
®

Transparencies ELABOTrainingsSysteme

Link LOGO! − PC

LOGO! Soft
Comfort

LOGO! PC cable

LOGO! 23
®

Transparencies ELABOTrainingsSysteme

The LOGO! Soft Comfort software

Program title bar

Menu bar

Icon bar

Icon bar tools

Status bar

LOGO! 24
®

Transparencies ELABOTrainingsSysteme

Program editing with


LOGO! Soft Comfort
Example program load, test Pump.LGO and transfer to
LOGO!
Load: File J Open J Pump.LGO J OK

LOGO! 25-1
®

Transparencies ELABOTrainingsSysteme

LOGO! 25-2
®

Transparencies ELABOTrainingsSysteme

LOGO! menu survey

LOGO! 26
®

Transparencies ELABOTrainingsSysteme

LOGO! 27

Das könnte Ihnen auch gefallen