Important: IBM® System i5® and eServer™ i5 models start counting logical partitions with
the number 1 (even if it is the only partition) instead of a 0. For the console to connect
properly, your logical partitions must also begin numbering at 1 instead of 0. This is
especially true if you rely on the BOOTP process to configure the server with its network
data.
For a configured twinaxial console, the device must be on port 0 with an address of 0.
For a configured twinaxial console, verify that the cursor is in the upper-left corner of the
display. This indicates the device is communicating with the controller correctly. If the cursor is
in the upper-right corner, the device and controller are not communicating. You might have a
defective adapter, the adapter might have to be reseated in the slot, or the controller is not
varied on.
When changing from or to a twinaxial console and the partition has completed an IPL into
i5/OS®, an additional IPL is required to complete the console change.