11. Troubleshooting
Problem Cause Remedy
Water is escaping from the spring Diaphragm in valve insert is faulty Replace valve insert
bonnet
Too little or no water pressure Shut-off valves upstream or downstream Open the shutoff valves fully
from domestic water station not fully open
Pressure reducing valve is not set to the Set outlet pressure
desired outlet pressure
Filter mesh dirty Reverse rinsing
Domestic water station not mounted in the Fit pressure reducing valve in flow direction
direction of flow (note direction of arrow on housing)
The outlet pressure set does not Filter mesh dirty Reverse rinsing
remain constant Valve insert, sealing ring or edge of nozzle Replace valve insert
is contaminated or worn
Rising pressure on outlet (e.g. in boiler) Check check valve, safety group etc.