Dynamic Insulation

Low energy, low carbon, high value

Energyflo = superior insulation


TM

+ lower carbon
+ improved indoor air quality
U-values below 0.10 in 140mm
Low envelope thickness construction
Building integrated filtration
TM
Energyflo Cells installed in Andrew H Wilson Ltd closed panel (SIP) system

EnergyfloTM Cell - The benefits Energyflo Cell - The product


TM

Increased Yield and Revenue per Hectare The energyfloTM cell transforms the building
• U value less than 0.10 performance in into a source of ventilation air, a heat
140 mm wall cavity exchanger and a filter of airborne pollutants
• Sale of greater usable floor space circa The product is a much higher performing
2-3% vs 190mm polyurethane solution
alternative to conventional insulation
Saves on Direct Building Costs
It is available in two thicknesses; 95mm
• Thinner wall envelopes or 140mm
• Down-spec on other low carbon
technologies Using mechanical or passive means,
ventilation air is drawn into the building
Improved Air Quality through the energyfloTM cell
• Building integrated filtration
• Zero maintenance for life of building
EnergyfloTM Cells being incorporated into
Housing Association project in association
with Lomond Timber Frame

TM
The Energyflo Cell

Building Integration
Energy Low thickness Filtration for the Life
Reduction building envelopes of the Building
0 .3 5
Dynamic u-value of Nano-Particle Filtration
TM

0 .3 0 the Energyflo cell 10000 supply duct


outside

0 .2 5 8000

0 .2 0
6000

0 .1 5
4000

0 .1 0

0 .0 5
2000
Ambiant pollution level

0 .0 0 0
16:00 17:00 18:00 19:00 20:00 21:00 22:00 23:00
Static Insulation Envelope Dynamic Insulation Envelope 0 0 .00 1 0. 00 2 0.0 0 3 0 .0 04 Time

A ir flo w V e locity ( m/s)


Pollution level after the energyflo TM

In a conventional building the The heat loss from the building In a DBB, a large area of the building
space heat energy is the sum of the envelope in a DBB is a function of envelope acts as a filter. The air
ventilation conductance and the the air velocity through the building velocities typical of a DBB encourage
fabric heat loss. In a DBB ventilation envelope not the thickness of filtration of particulate matter
air is drawn into the building (either insulating layer. As the air velocity through the depth of the filter media
mechanically or passively) through increases, more heat is transferred rather than at the surface. As a
the energyfloTM. The ventilation air is to the incoming ventilation air. It is consequence, the building integrated
pre warmed by by 5-8°C conductive possible to specify buildings with filtration systems in the DBB will last
losses that would otherwise be lost to near zero heat loss envelopes. for the lifetime of the building. This
the building. As a consequence, low As a consequence, low heat loss, attribute allows ventilation without
heat loss building envelopes can be low thickness building envelopes recourse to the openings in the
constructed. can be constructed. building envelope.