Sie sind auf Seite 1von 8

WANG Hong WU Bao-ming

,WANG Hong(400042,,;400050,
) ,WU Bao-ming(,
,400042)

INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING


200831(4)
0

()

(19)
1.Hanlon EB;Manoharan R;Koo TW Prospects for in vivo Raman spectroscopy 2000(02)
2.Waynant RW;Chenault VM Overview of non-invsaive fluid glucose measurement using optical techniques
to maintain gluocse control in diabetes mellitus 1998(02)
3.Kurnlk R;Oliver J;Waterhotme S Application of the Mixtures of Experts algorithm for signal
processing in a noninvasive glucose monitoring system 1999(01)
4.Latin KV;Eledrisi MS;Motamedi M Noninvasive blood glucose monitoring with optical coherence
tomography:a pilot study in human subjects 2002(12)
5.Heinemann L;Kramer U;Klotzer HM Noninvasive glucose measurement by monitoring of scattering
coefficient during oral glucose tolerance tests.Nou-Invasive Task Force 2000(02)
6.Brancaleon L;Bamberg MP;Sakamaki T Attenuated total reflection-Fourier transform infrared
spectroscopy as a possible method to investigate biophysical parameters of stratum corneum in vivo
2001(03)
7.Gebhart S;Faupel M;Fowler R Glucose sensing in transdermal body fluid collected under continuous
vacuum presaure via micropores in the stratum comeum 2003(02)
8.Gourzi M;Rouane A;Guelaz R Study of a new electromagnetic sensor for glycaemia measurement:in
vitro results on blood pig 2003(06)
9.Ermolina I;Polevaya Y;Feldman Y Analysis of dielectric spectra of eukaryotic cells by computer
modeling 2000(02)
10.Marbach R;Koschinsky T;Gries F Noninvasive Blood Glucose Assay by Near-Infrared Diffuse
Reflectance Spectroscopy of the Human Inner Lip 1993(07)
11.Mazarevica G;Freivalda T;Jurka A Properties of erythrocyte light refraction in diabetic patients
2002(02)
12.Sibbald RG;Landolt SJ;Toth D Skin and diabetes 1996(02)
13.Caspers PJ;Lucasaen GW;Puppels GJ Combined in vivo confocal Raman spectroscopy and conforal
microscopy of human skin 2003(01)
14.Tarr RV;Steffes PG The non-invasive measure of D-glucose in the ocular aqueous humor using
stimulated Raman spectroscopy 1998(02)
15.Khalil OS Non-invasive glucose measurement technologies:an update from 1999 to the dawn of the
new millennium 2004(05)
16.Domschke A;March WF;Kabilan S Initial clinlcal testing of a holographic non-invasive contact lens

glucose sensor 2006(01)


17.Sandby-Moller J;Potdsen T;Wulf HC Influence of epidermal thickness,pigmentation and redness on
skin autofluorescence 2003(06)
18.Shen Yao-chun;Lu Zu-hong;Spiers S Measurement of the optical absorption coefficient of a liquid
by use of a time-resolved photoacoustic technlque 2000(22)
19.McNichois RJ;Cameron BD;Cote GL Development of a NonInvasive Polarimetric Glucose Sensor 1998(02)

(10)
1. ... -2004,15(2)
,,
30 s,.,(PLS),
(RMSEP)0.56 mmol/L0.50 mmol/L.

2. 2008

--

intralipid

Intralipid
t
IntralipidIntralipid
2intralipid

3. ZHANG Yan-jie..ZHANG Wen-hua..ZHANG Yan-jie.YANG Yan-fang.ZHANG Wen-hua.ZHOU


Zhi-zun -2008,25(4)
:,.:1400 nm1800nm2000 nm2500nm.60,Nexus-870,,
(PLS).20,,:2000 nm-2 500 nm,
0.998,(RMSEP)0.045.:,
,,..

4. 2009

<br>

2Intralipid
1525nm1832nm2062nm2Intralipid2090nm2180nm
<br>

0.0370.1

<br>

21.7
11.7

5. ...ZHANG Yue.L(U) Li-na.XU Ke-xin


-2005,25(4)
, . 1 5601 750 nm2 0902 190 nm,
, (MSC), (PLS). 2
0902 190 nm, , 0.99, (RMSEP)0.045.
.

6. 2005

OGTT()OGTT
PLS()50OGTT
0.67730.0886mmol/l

7. P3 2009

P3<br>
MieMie
<br>
P3

<br>
intralipid
P3a'0.93P3
0.93a'0.3P31313nm
MCMLP3
(Iglu/Inet)

8. ...LIU Rong.GU Xiao-yu.XU Ke-xin


-2008,28(8)
,,,.
.,
,,,.
.,Intralipid-2%,,
25.9%40.1%.

9. 2008

-
AAT
AC1200nm-1700nm1
mmol/L

0.04AT
AC

3032
403030
250

10. .... -2004,10(4)


,.AOTF(),
,3OGTT(),.PLS()
RMSEP()0.69mmol/L0.49mmol./L0.54mmol/L.

http://d.wanfangdata.com.cn/Periodical_gwyx-swyxgc200804009.aspx
2011525