Engine Parameters
Ignition System Starting System Fuel Tank Capacity (L) (Kerosene run) Fuel Tank Capacity (L) (Petrol Starting) Continuous running hours (Hrs.) TCI Recoil Starter 2.7
Generator Parameters
Frequency (Hz) Rated Output (VA) Maximum Output (VA) DC Output Dry Weight (Kg) L x W x H (mm) 50 350 VA 450 VA ----21.5 Kg 407 x 335 x 407
Standard Features
Fuel Cock Pilot Lamp Oil Alert Fuel Gauge -----------
Please call local Area Office to get the price in your town / City.
Engine Parameters
Ignition System Starting System Fuel Tank Capacity (L) (Kerosene run) Fuel Tank Capacity (L) (Petrol Starting) Continuous running hours (Hrs.) TCI Recoil Starter 3.4
Generator Parameters
Frequency (Hz) Rated Output (VA) Maximum Output (VA) DC Output Dry Weight (Kg) L x W x H (mm) 50 450 VA 550 VA ----22 Kg 414 x 310 x 364
Standard Features
Fuel Cock Pilot Lamp Oil Alert Fuel Gauge ---------
Please call local Area Office to get the price in your town / City.
Engine Parameters
Ignition System Starting System Fuel Tank Capacity (L) (Kerosene run) Fuel Tank Capacity (L) (Petrol Starting) Continuous running hours (Hrs.) TCI Recoil Starter -----
Generator Parameters
Frequency (Hz) Rated Output (VA) Maximum Output (VA) DC Output Dry Weight (Kg) L x W x H (mm) 22 Kg 409 x 270 x 374 50 450 VA 550 VA
Standard Features
Fuel Cock Pilot Lamp Oil Alert Fuel Gauge Please call local Area Office to get the price in your town / City. Standard
Engine Parameters
Ignition System Starting System Fuel Tank Capacity (L) (Kerosene run) Fuel Tank Capacity (L) (Petrol Starting) Continuous running hours (Hrs.) TCI Recoil Starter 6.1
Generator Parameters
Frequency (Hz) Rated Output (VA) Maximum Output (VA) DC Output Dry Weight (Kg) L x W x H (mm) 50 650 VA 750 VA ----30 482 x 328 x 438
Standard Features
Fuel Cock Pilot Lamp Oil Alert Fuel Gauge Please call local Area Office to get the price in your town / City. -----
Engine Parameters
Ignition System Starting System Fuel Tank Capacity (L) (Kerosene run) Fuel Tank Capacity (L) (Petrol Starting) Continuous running hours (Hrs.) TCI Recoil Starter 9.1
Generator Parameters
Frequency (Hz) Rated Output (VA) Maximum Output (VA) DC Output Dry Weight (Kg) L x W x H (mm) 50 1000 VA 1300 VA ----74 890 x 431 x 686
Standard Features
Fuel Cock Pilot Lamp Oil Alert Fuel Gauge Please call local Area Office to get the price in your town / City. Plunger type -----
Engine Parameters
Ignition System Starting System Fuel Tank Capacity (L) (Kerosene run) Fuel Tank Capacity (L) (Petrol Starting) Continuous running hours (Hrs.) TCI Recoil Starter 9.1
Generator Parameters
Frequency (Hz) Rated Output (VA) Maximum Output (VA) DC Output Dry Weight (Kg) L x W x H (mm) 50 1000 VA 1300 VA ----81 890 x 431 x 686
Standard Features
Fuel Cock Pilot Lamp Oil Alert Fuel Gauge Please call local Area Office to get the price in your town / City. Plunger type -----
Engine Parameters
Ignition System Starting System Fuel Tank Capacity (L) (Kerosene run) Fuel Tank Capacity (L) (Petrol Starting) Continuous running hours (Hrs.) TCI Recoil Starter / Electric Starter 9.1
Generator Parameters
Frequency (Hz) Rated Output (VA) Maximum Output (VA) DC Output Dry Weight (Kg) L x W x H (mm) 50 1400 VA 1600 VA / ----76 890 x 431 x 686
Standard Features
Fuel Cock Pilot Lamp Oil Alert Fuel Gauge Please call local Area Office to get the price in your town / City. Plunger type
Engine Parameters
Ignition System Starting System Fuel Tank Capacity (L) (Kerosene run) Fuel Tank Capacity (L) (Petrol Starting) Continuous running hours (Hrs.) TCI Recoil Starter / Electric Starter 9.1
Generator Parameters
Frequency (Hz) Rated Output (VA) Maximum Output (VA) DC Output Dry Weight (Kg) L x W x H (mm) 50 1400 VA 1600 VA ----83 890 x 430 x 685
Standard Features
Fuel Cock Pilot Lamp Oil Alert Fuel Gauge Please call local Area Office to get the price in your town / City. Plunger type
Engine Parameters
Ignition System Starting System Fuel Tank Capacity (L) (Kerosene run) Fuel Tank Capacity (L) (Petrol Starting) Continuous running hours (Hrs.) TCI Recoil Starter 9.1
Generator Parameters
Frequency (Hz) Rated Output (VA) Maximum Output (VA) DC Output Dry Weight (Kg) L x W x H (mm) 50 1400 VA 1600 VA / ----76 890 x 431 x 686
Standard Features
Fuel Cock Pilot Lamp Oil Alert Fuel Gauge Please call local Area Office to get the price in your town / City. Plunger type
Engine Parameters
Ignition System Starting System Fuel Tank Capacity (L) (Kerosene run) Fuel Tank Capacity (L) (Petrol Starting) Continuous running hours (Hrs.) TCI Recoil Starter 15.5
Generator Parameters
Frequency (Hz) Rated Output (VA) Maximum Output (VA) DC Output Dry Weight (Kg) L x W x H (mm) 94 985 x 471 x 723 50 2100 VA 2400 VA
Standard Features
Fuel Cock Pilot Lamp Oil Alert Fuel Gauge Please call local Area Office to get the price in your town / City. Plunger type
Engine Parameters
Ignition System Starting System Fuel Tank Capacity (L) (Kerosene run) Fuel Tank Capacity (L) (Petrol Starting) Continuous running hours (Hrs.) TCI Recoil Starter / Electric Starter 15.5
Generator Parameters
Frequency (Hz) Rated Output (VA) Maximum Output (VA) DC Output Dry Weight (Kg) L x W x H (mm) 50 2100 VA 2400 VA -----102 985 x 471 x 723
Standard Features
Fuel Cock Pilot Lamp Oil Alert Fuel Gauge Please call local Area Office to get the price in your town / City. Plunger type
Engine Parameters
Ignition System Starting System Fuel Tank Capacity (L) (Kerosene run) Fuel Tank Capacity (L) (Petrol Starting) Continuous running hours (Hrs.) TCI Recoil Starter -----**
Generator Parameters
Frequency (Hz) Rated Output (VA) Maximum Output (VA) DC Output Dry Weight (Kg) L x W x H (mm) 50 450 VA 550 VA ----22.5 Kg 415 x 310 x 364
Standard Features
Fuel Cock Pilot Lamp Oil Alert Fuel Gauge -------------
Please call local Area Office to get the price in your town / City.
Engine Parameters
Ignition System Starting System Fuel Tank Capacity (L) (Kerosene run) Fuel Tank Capacity (L) (Petrol Starting) Continuous running hours (Hrs.) TCI Recoil Starter -----**
Generator Parameters
Frequency (Hz) Rated Output (VA) Maximum Output (VA) DC Output Dry Weight (Kg) L x W x H (mm) 50 1400 1600 ----46 545 X 355 X 475
Standard Features
Fuel Cock Pilot Lamp Oil Alert Fuel Gauge -------------
Please call local Area Office to get the price in your town / City.
RUN ALL YOUR Air Conditioner Refrigerator Television Light/ Fans, etc. ALL AT ONE TIME*
*conditons apply
*At 25% load **At rated load. (With Eco-Throttle switch on) ^with handle folded ^^with handle open
RUN ALL YOUR Air Conditioner Refrigerator Television Light/ Fans, etc. ALL AT ONE TIME*
*conditons apply
* Max Output #Optional Cable Remote ** Parallel connection to be done by authorised dealer only.
3000 VA 2800 VA HONDA GX200T/OHV, Single Cylinder, Air Cooled Electronic Governor (Load Senstive) Auto i-Monitor Equipped Electric / Recoil Start Unleaded Petrol 12.5 6.9* Yes Yes Yes 62 710x482x570
MODEL CALCULATOR (0nly for Gensets) to know the model for your requirement.
Honda Siel Power Products offers a range of Portable Power Products viz, Gensets, Engines, Water Pumping sets, Lawnmower and Brush Cutters
Special Features
Due to the Honda's innovative technology, this new age generator is so silent that you might actually want to check if its on. In fact to make it a complete standby power source, every possible detail has been kept in mind while designing its features.
Super Silent
Honda GenX is equipped with a revolutionary sound absorption system. Its large size sound mufflers help absorb the operating noise of the engine - so you can relax even during a power cut. Moreover, the generator meets the applicable Noise Regulation (Phase-II) of Central Pollution Control Board (Govt. of India).
Eco Friendly
Unlike the conventional generators, the low fume engine of Honda GenX keeps your house and environment comfortable. At par with the international standards, it strictly conforms to the stringent applicable emission norms of Central Pollution Control Board (Govt. of India).
A Tough Performer
Every Honda GenX is put through a series of stringent performance and quality tests before it becomes a part of your home. The generator has 3 chambers for improved thermal balance. So it never fails to comfort you even in those never ending powercuts.
Its specially designed castor wheels, the top and bottom handle, make it easy for you to move the machine around. Its Oil Alert Device (standard feature) prevents engine seizure. Its plunger type fuel cock helps in starting the generator conveniently. And thanks to its dual type carburetor, no drainage of kerosene is required. What's more, for every maintenance, every model comes with a special tool kit and a fuel funnel.
Fuel Efficiency
For your convenience you can keep a constant check on the fuel levels.
Honda Portable Gensets have an Oil Alert System that prevents Engine Seizure due to low oil level.
Circuit Breaker
An inbuilt Circuit Breaker prevents the alternator from being damaged in case of a short circuit.
Service Network
A countrywide network of over 700 dealers spread across the country makes aftersales service and spares easily available.
Easy To Carry
Special muffling minimising noise levels. Meeting national standards of air emission regulation.
Options