Model T50HHDTBNA
R407C
rev 9/4/07
Contents
Performance Data Specifications
1. Performance data 2. Dimensions 3. The display 4. Wiring diagram
1 2 3 8 9
Service
1. How to Obtain Service
Attachments
1. The charts displayed for outdoor pools & indoor pools 2. The Installation With Chlorinator 3. Conversion Tables
10 13 14
Code
Rated heating capacity Input power heating Running current heating COP Power supply Number of compressors Compressor Number of fans Input power of fan Fan rotation speed Noise Water connection size Water flow Water pressure drop Refrigerant(R407C) L Net dimension W H Shipping dimension Weight L W H Net weight
Gross weight
TH50HHDTBNA
W BTU/h W A V/PH/HZ
11300 38500 2306 10.6 4.9 220V/1PH/50HZ 1 Rotary 1 200 830 60 1-1/2 4-7 15 2.3 660 660 850 780 820 1040 87 93
mm Kg
Measurement conditions: Outdoor air temp: 24C to 19C, inlet water temp: 27C, ambient temp range: 0~35C
1 3
Code Specs
TH50HHDTBNA
4mm
2
Power supply installation condition: Thus a breaker with more than 3mm touching point space.
660
660
850
2 3
80
370
Initialization
SET
TEMP
IN
NO.
ROOM
HUM
MIN
C F
MIN
TEMP
C F
ON OFF
FAN AUTO
1 2
AUX
AUX
Press to turn Press M button on and turn off to change modes the units.
Press Set to set operation parameter under stand by status, or check the operation parameter under running or stand by status.
2)How to set operation parameter : Standby status, press SET button to enter Operation Parameter setting interface; Press SET again to start setting (parameter from 00-1 (see the Operation Parameter Table page-5); Under parameter setting, parameter 00-01can be set by pressing or ; 02-10 must be set only after pressing and at the same time for 3s, get a sound of Beep to unlock. Data will be stored in 3s without any press on the controller. Parameter 02-10 must be adjusted by professional technicians. Please note no press in 5s, the LCD will display water-in/water out temp. (under running) or ambient temp. (Under standby status) Whilst running , you can press SET to check current parameter, but data of parameter can not be changed !
Remarks: Standby status means the unit is connected with electricity but not running . Parameter 00-10 can only be changed under standby status!
SET
NO.
SET
NO.
SET
NO.
MIN
Parameter 00 to set inlet water temp. under cooling mode (8-28 C) default setting:12 C
AUX
Parameter 01 to set inlet water temp under heating mode (15-40C) default setting: 40C
AUX
AUX
SET
NO.
SET
NO.
SET
NO.
MIN
C
Parameter 03 Setting initialization temp for defrosting " -7C ", (" - " not display, range(0- -30C)
C
Parameter 04 Terms of Exit Defrosting Function (2-30C) default setting:13C
5 3
AUX
AUX
5 3
AUX
SET
NO.
SET
NO.
VALVE
SET
NO.
AUX
AUX
AUX
SET
NO.
VALVE
SET
NO.
VALVE
" 0 " long time working for water pump " 1 " water pump turns off after the whole unit power off for 30s initialization " 0 ".
AUX
AUX
4 3
Range
Adjust(yes/no)
00 01 02 03 04 05 06 07 08 09 10
8-30C 15-40C 30-90MIN 0--30C 2-30C 1-12MIN 1-2 0-1 1-3 0-1 8-40C
3 (hot water)
0 30C
IN
OUT
ROOM
TEMP
TEMP
AUX
AUX
AUX
Condenser 2 temp.
Under running status , press and to check the current status of the unit! You can check water-in/water out temp, condenser temp and ambient temp, please note no motion on the display for 5s, the LCD will display water-in/water out temp/(under running) or ambient temp. (unit stops)
15
AUX
5 3
ROOM
IN
TEMP
OUT
TEMP
AUX
AUX
Under running or standby status press and at the same time for 5s, controller will be locked, display as above. Press and again for 5s for unlocking.
5)Troubleshooting
Malfunction
Water in temp. Sensor failure Water out temp. Sensor failure Coil1 sensor failure
Coil 2 sensor failure (proprietary for A type)
Wire Controller
PP 01
Reason
The sensor is open or short circuit The sensor is open or short circuit The sensor is open or short circuit The sensor is open or short circuit The sensor is open or short circuit Insufficient water flow or water pressure difference is too little Insufficient water flow Too low Too low The system1 protection was failure The system2 protection was failure No water/little water in water system. Wrong connections or lack of connection Water flow volume not enough, water pressure difference is too low
Resolution
Check or change the sensor
PP 02
PP 03 PP 04 PP 05
Check or change the sensor Check or change the sensor Check or change the sensor
Ambient sensor failure Temp. differential is too large between water-in and water-out Defrosting under cooling mode The first time freezing protection in winter The second time freezing protection in winter Malfunction of system1 Malfunction of system2 (cut off under low voltage) Flow switch failure Power supply connections wrong (for 3phase unit) Hi/Low pressure protection (for single phase unit) 3 times water-in and water-out temp. difference protection in 30 minutes Defrosting Communication failure
PP 06 PP 07 PP 08 PP 09
Check the water flow volume, or clogged plumbing system Check the water flow volume, or clogged plumbing system
EE 01
Check each protection point of system1 remove the malfunction according to System Protection Board malfunction table. Check each protection point of system2 remove the malfunction according to System Protection Board malfunction table. Check the water flow volume, or clogged plumbing system
EE 02 EE 03
EE 04
6 3
FAN
COMP1
HI FAN
MDOUT
COMP2
PUMP
Chiller 300
WATER KYOUT FROST MDIN KYIN GND GND GND GND GND GND NET SYS 12V 12V
ROOMT PIPE2 PIPE1 OUTWT INWT
Connections explanation:
No.
Symbol
HI FAN PUMP FAN VAL2 VAL1 COMP2 COMP1 AC-L AC-N KYOUT GND MDOUT GND NET GND 12V KYIN MDIN
WATER GND FROST GND SYS GND 12V
VAL2
AC-N
AC-N
AC-L
AC-N
VAL1
Meaning
High speed for fan Water pump (220VAC) Fan motor (220VAC) 4way valve of system2 (220VAC) (no use) 4way valve of system1 (220VAC) Compressor of system2 (220VAC) (no use) Compressor of system1 (220VAC) Live wire
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
Neutral wire On/Off switch (output) (no use) Mode output (no use) Wire controller On/Off Switch (input) (no use) Model (input) (no use) Flow switch (input) ( normal close) Defrost signa l(no use) System protection (input) (normal close) Ambient temp. (input) Temp of fan coil2 ( input) (no use)
Temp of fan coil 1 (input) (no use for split type )
3 7
Electric diagram:
K2 Y/G
DEFROSTING VALVE
BLU BLU
RK1
COMP
PUMP
COMP1
HI LOW AC-N
VAL1
AC-N
AC-L
K1
RED
Chiller 300
WATER
N
MDIN
KYIN
GND
GND
GND
SYS
GND
NET
12V
ROOMT
BRN
BLU
Y/G
t`
t`
t`
t`
OUT
EXT.
8 3
LP
Wire Controller
SW1
HP 1
TO POWER SUPPLY
9 3
Jul
Aug
Sep
Oct
Nov
Dec
Jan
Feb
Mar
Apr
May
Jun
Jul
Aug
Sep
Oct
Nov
Dec
Jan
Feb
Mar
Apr
May
Jun
10 3
Jul
Aug
Sep
Oct
Nov
Outside
Dec
Jan
Feb
Mar
Apr
Jul
Aug
Sep
Oct
Nov
Dec
Jan
Feb
Mar
Apr
3 11
Relative
Jul
Aug
Sep
Oct
Nov
Dec
Jan
Feb
Mar
Apr
May
Jun
Outlet
Inlet
Inlet
Heat pump
Side 600 mm Side 600 mm
12 3
TITANIUM EXCHANGER
VAL2
VAL1
FAN 12V
Chiller 300
WATER FROST MDIN KYIN GND GND GND GND SYS 12V
ROOMT PIPE2 PIPE1 OUTWT INWT
COMP2
COMP1
AC-N
AC-N
AC-N
AC-L
A SERIES
Please start up the water switch (outside), if the inside one (in the machine) is not open since the water flow is not enough.
WATER FLOW SWITCH (outside)
WATER PUMP
WATER FLOW
13 3
Square Measure
1 square inch =6.45 sq.centimetres 1 square foot =144 sq.in.=9.29 sq.decimetres 1 square yard =9 sq.ft. =0.836 sq.metre 1 acre =4840 sq.yd.=0.405 hectare 1 square mile =640 acres =259 hectares
Cubic Measure
1 cubic inch =16.4 cu.centimetres 1 cubic foot =1728 cu.in. =0.0283 cu.metre 1 cubic yard =27 cu.ft. =0.765 cu.metre
Capacity Measure
British 1 pint 20 fluid oz. =34.68 cu.in. =0.568 litre 1 quart =2 pints =1.136 litres 1 gallon =4 quarts =4.546 litres 1 peck =2 gallons =9.092 litres 1 bushel =4 pecks=36.4 litres 1 quarter =8 bushels =2.91 hectolitres American dry 1 pint =33.60 cu.in. =0.550 litre 1 quart =2 pints =1.101 litres 1 peck =8 quarts =8.81 litres 1 bushel =4 pecks =35.3 litres American liquid 1 pint =16 fluid oz. =28.88 cu.in. =0.473 litre 1 quart =2 pints =0.946 litre 1 gallon =4 quarts =3.785 litres
Avoirdupois Weight
1 grain =0.065 gram 1 dram =1.772 grams 1 ounce =16 drams =28.35 grams 1 pound =16 ounces =7000 grains =0.4536 kilogram 1 stone =14 pounds =6.35 kilograms 1 quarter =2 stones =12.70 kilograms 1 hundredweight =4 quarters =50.80 kilograms 1 short ton =2000 pounds =0.907 tonne 1 (long) ton =20 hundredweight =1.016 tonnes
Energy power
1 usrt =3024 kcal/h=3516 w 1 kcal/h =1.163 w 1 kw =860 kcal/h 1 btu/h =0.293 w
Velocity, flux
1 m/s =196.85 fpm 1 cfm = 1.699cmh 1 gpm =0.27276 cmh 1 gpm =0.2271 cmh
Pressure
1 bar =100000 pa 1 psi =0.0703 kgf/cm2 1 kgf/cm2 =98000 pa 1 mm aq. =9.8 pa 1 mm hg =133.28 pa 1 m H2O =9800 pa =0.1 kgf/cm2
14 3