NetMaster Customer Support Information Table of Contents

CUSTOMER SUPPORT INFORMATION


SW-NETMASTER-SERVER SW-NETMASTER-GUI-CLIENT SW-NETMASTER-SNMP-AGENT SW-NOKIA-NETACT-BRIDGE
Subject: 1. Release of R10M01 2. New functionality 3. Errors corrected 4. Known Issues

Copyright 2009 - Nera Networks


CSI

Page 1(8)

Customer Support Information (CSI)


Rev Date Rev. Document ID

2009-10-12

U NetMaster

15892-891861

TABLE OF CONTENTS 1. 2. 3. 3.1 3.2 4. 5. 5.1 5.2 5.3 5.4 5.5 5.6 5.7 5.8 5.9 5.10 5.11 5.12 5.13 6. INTRODUCTION ............................................................................................................... 3 SOFTWARE VERSION HISTORY .................................................................................... 3 NEW FUNCTIONALITY..................................................................................................... 4 Inventory Management Reporting via Northbound Interface............................................. 4 Network Element integration changes/updates ................................................................. 4 ERRORS CORRECTED ................................................................................................... 4 KNOWN ISSUES............................................................................................................... 5 Maintenance Installation.................................................................................................... 5 Upgrade to current NetMaster release Permission settings ........................................... 5 Alarm Templates ............................................................................................................... 5 NetMaster displays blocked alarms for CityLink elements with older IDU firmware .......... 5 Limited client functionality during NetMaster server start-up phase .................................. 5 WiLink I SW Inventory ....................................................................................................... 6 Use of character set in element names ............................................................................. 6 Limitations on number of elements in NetMaster .............................................................. 6 Performance Measurements limitations ............................................................................ 6 NE handling in NetMaster during NE maintenance operations ......................................... 7 TCA not supported for Evolution Series ............................................................................ 7 Oracle database tuning issue for alarm list retrieval.......................................................... 7 Upgrade of large database ................................................................................................ 7 FURTHER INFORMATION ............................................................................................... 8

Copyright 2009 - Nera Networks


CSI

Page 2(8)

Customer Support Information (CSI)


Rev Date Rev. Document ID

2009-10-12

U NetMaster

15892-891861

1. INTRODUCTION
This document describes changes and corrections in the software components of the NetMaster software.

2. SOFTWARE VERSION HISTORY


Current release in bold.
SW-NETMASTERSERVER R10A00 R10B00 R10B01 R10C00 R10D00 R10E00 R10F00 R10G00 R10G01 R10G04 R10G05 R10H00 R10H01 R10H02 R10H03 R10H04 R10J00 R10K00 R10K01 R10L00 R10L01 R10M00 R10M01 SW-NETMASTERGUI-CLIENT R10A00 R10B00 R10B01 R10C00 R10D00 R10E00 R10F00 R10G00 R10G01 R10G04 R10G05 R10H00 R10H01 R10H02 R10H03 R10H04 R10J00 R10K00 R10K01 R10L00 R10L01 R10M00 R10M01 SW-NETMASTERSNMP-AGENT R10C00 R10D00 R10E00 R10F00 R10G00 R10G01 R10G04 R10G05 R10H00 R10H01 R10H02 R10H03 R10H04 R10J00 R10K00 R10K01 R10L00 R10L01 R10M00 R10M01 SW-NOKIANETACT-BRIDGE R1A00 R10E00 R10F00 R10G00 R10G01 R10G04 R10G05 R10H00 R10H01 R10H02 R10H03 R10H04 R10J00 R10K00 R10K01 R10L00 R10L01 R10M00 R10M01 Release date 15.07.2005 09.12.2005 13.01.2006 06.06.2006 14.07.2006 29.09.2006 22.12.2006 23.04.2007 22.06.2007 18.09.2007 02.11.2007 14.03.2008 16.05.2008 27.05.2008 04.07.2008 15.08.2008 26.09.2008 26.02.2009 01.04.2009 05.06.2009 30.06.2009 25.09.2009 12.10.2009

Table 2.1: NetMaster software release history

Copyright 2009 - Nera Networks


CSI

Page 3(8)

Customer Support Information (CSI)


Rev Date Rev. Document ID

2009-10-12

U NetMaster

15892-891861

3. NEW FUNCTIONALITY 3.1 Inventory Management Reporting via Northbound Interface


The Northbound SNMP Interface now has the capability to present inventory information regarding the managed Nes. It is possible to retrieve information regarding and the current HW and SW configuration of each NE. A notification can be sent to the Nortbound Client each time the system discovers a change in the inventory, such as SW updates, insertion/deletion of NE modules, or discovery of new NEs.

3.2 Network Element integration changes/updates 3.2.1 Updated support for SmartPack series
SmartPack integration supports:
Network Element System configurations Supported hardware rev. Supported software rev. SmartPack Minipack, Flatpack2, Powerpack All 4.3, 4.2a and 4.1, SNMP version 2c

In general, it is recommended to avoid sofware versions older than 4.3, due to known functional limitations and communications capacity problems on the NE.

4. ERRORS CORRECTED
The current release addresses a number of issues. The most important ones are listed here. If required, further details may be requested via the CSS Help Desk.
Id 3541, 3556 3561, 3584, 3596 3603 Summary Weakness in alarm reconcile function, in some cases alarms were still incorrectly shown as active. Weakness in alarm reconcile function, in some cases alarms were still incorrectly shown as active. Slow opening of Historical Alarm reports, under heavy load the view fails to open due to timeout. Retrieval time reduction in R10M00 is appr. 30 to 80% (depending on actual data set) compared to R10L01. In extreme cases the Historical Alarms View may still fail if the retrieval takes more than appr. 7 minutes. If reading of PM resource capabilities on NE fails during discovery of NE, the system later fails if trying to collect PM data from these NEs. Weakness in alarm reconcile funtion, elements could become out of alarm synchronisation after connection problems combined with manual reset of element log. Applies to CityLink/InterLink Evolution Fixed in R10M00 R10M00

Historical Alarms View

R10M00

3532 3618, 3619, 3622

NE integration framework CityLink/InterLink

R10M00 R10M01

Table 4.1: Errors corrected in current release.

Copyright 2009 - Nera Networks


CSI

Page 4(8)

Customer Support Information (CSI)


Rev Date Rev. Document ID

2009-10-12

U NetMaster

15892-891861

5. KNOWN ISSUES 5.1 Maintenance Installation 5.1.1 Observations


Running Maintenance Installation on a NetMaster client-only installation fails when trying to add NetMaster server.

5.1.2 Workaround
Uninstall the NetMaster client and then perform a new installation.

5.2 Upgrade to current NetMaster release Permission settings 5.2.1 Observations


After upgrade to current NetMaster release, any action permissions of type Configuration/Inventory Views given to a security group is disabled.

5.2.2 Workaround
Administrator must grant the user groups permissions to Configuration/Inventory Views using the User Group Administration view.

5.3 Alarm Templates 5.3.1 Observations


Assigning an alarm template for SmartMetro will not have any effect.

5.3.2 Workaround
None identified.

5.4 NetMaster displays blocked alarms for CityLink elements with older IDU firmware 5.4.1 Observations
NetMaster displays blocked alarms for CityLink elements with older IDU firmware. This is caused by a defect in the CityLink IDU firmware.

5.4.2 Workaround
Upgrade to IDU application code level higher than R3H00 solves the problem.

5.5 Limited client functionality during NetMaster server start-up phase 5.5.1 Observations
It is possible to login to the NetMaster client short time after a server start-up (or restart) has been initiated. However, it may take some time until all client functionality is enabled. The amount of time depends on the network size.

Copyright 2009 - Nera Networks


CSI

Page 5(8)

Customer Support Information (CSI)


Rev Date Rev. Document ID

2009-10-12

U NetMaster

15892-891861

5.5.2 Workaround
Wait until message: System started in X minutes appears in the NetMaster Server log before attempting to use the client.

5.6 WiLink I SW Inventory 5.6.1 Observations


The SW Inventory view for WiLink I is empty after NetMaster installation.

5.6.2 Workaround
Perform a manual SW Reconcile action for the elements in question.

5.7 Use of character set in element names 5.7.1 Observations


NetMaster has inconsistent handling of special language characters in element names (------ etc).

5.7.2 Workaround
To avoid operator confusion and possible errors, it is recommended to use only international characters in element names.

5.8 Limitations on number of elements in NetMaster 5.8.1 Observations


We recommend keeping the total number of managed elements on one NetMaster server within these limitations: Total number of elements should not exceed 1500, out of which: Evolution Series elements Max 1500. Other SNMP elements (CityLink FE/CompactLink/WiLink I/SmartMetro/etc) Max 500 CityLink/InterLink and other Q1 elements Max 700 SmartPack Max 200 These recommendations apply independently from purchased and installed licenses.

5.8.2 Workaround
Consult Customer Support if system requirements exceed these limitations.

5.9 Performance Measurements limitations 5.9.1 Observations


Due to DCN and Server processing limitations still present in the current NetMaster version, it is recommended to collect only 24h measurements on a general basis, and utilise 15min measurements for temporary troubleshooting purposes.

5.9.2 Workaround
None identified.

Copyright 2009 - Nera Networks


CSI

Page 6(8)

Customer Support Information (CSI)


Rev Date Rev. Document ID

2009-10-12

U NetMaster

15892-891861

5.10 NE handling in NetMaster during NE maintenance operations 5.10.1 Observations


Moving elements in or out of managed state during the period that a software download, element restart, or configuration backup/restore operation is taking place may have unwanted side effects on NetMaster and/or the elements.

5.10.2 Workaround
Moving elements in or out of managed state during the period that a software download, element restart, or configuration backup/restore operation is taking place should in general be avoided.

5.11 TCA not supported for Evolution Series 5.11.1 Observations


It has been reported that Threshold Crossing Alerts are not working as expected for Evolution Series NEs in the new integration framework.

5.11.2 Workaround
None identified. The error will be fixed in a software update in the future (contact Customer Support for availability info if TCA is used).

5.12 Oracle database tuning issue for alarm list retrieval 5.12.1 Observations
It has been reported that the response time for presenting alarm lists in NetMaster is not satisfactory in some cases. Investigations show that this may be related to incorrect tuning of the Oracle database, i.e. that database instance having too little memory.

5.12.2 Workaround
Use the Advisor General in Oracle Enterprise Manager to verify if too little SGA memory is causing the problem. The System Global Area should be 90% of total physical memory on the standalone database server. Further reading: For Oracle 11G systems, see: http://download.oracle.com/docs/cd/B28359_01/server.111/b28301/instance004.htm#insertedID3. For Oracle 10G systems, see: http://download.oracle.com/docs/cd/B19306_01/server.102/b25416/ch8.htm#i85390

5.13 Upgrade of large database 5.13.1 Observations


If the database that is being upgraded to a new version is very large, the process may take several days to complete. There is no indication of estimated duration or percentage completed.

Copyright 2009 - Nera Networks


CSI

Page 7(8)

Customer Support Information (CSI)


Rev Date Rev. Document ID

2009-10-12

U NetMaster

15892-891861

5.13.2 Workaround
It is recommended to reduce the database size before the upgrade of large databases. This can be done by using the maintenance features to delete old alarms from the database before initiating the upgrade process.

6. FURTHER INFORMATION
For details on how to contact Customer Support see our web: www.neraworld.com.