Sie sind auf Seite 1von 4

OIL CONTENT ANALYZER

OCMA-350

Easy-to-read backlit LCD


The backlit LCD is easy to read under any conditions, including bright sunlight. The digital display eliminates individual reading differences.

Cell control
To introduce your sample into the removable cell, just pull the cell out of its holder. Its easy to avoid leaks and spills when you have this much control. The removable cell is also easy to maintain.

Three measurement units


The OCMA-350 measures in mg/l for oil in water, mg/kg for oil in soil, and Abs. for the absorbency of oil, so you can always choose the proper unit for your sample measurement.

Plug it in, and its on stand-by. The press of just one button starts the measuring process. You can even use your PC to simplify operation.

Pushbutton simplicity, perfect for field analysis.


Compact and simple, HORIBAs OCMA-350 oil content analyzer delivers quick, accurate measurements in the lab or in the field. It efficiently measures the level of oil in water or soil for environmental applications, checks for residual oil on semiconductor parts which have been cleaned, and measures oil on any industrial surface. Using the OCMA-350 is almost effortless. Simply inject the extract from your sample, dissolved in Horibas S-316 solvent, into the measuring cell, and press one button. You can even use your PC to simplify operation.
Recommended Applications
Environment: Surveying water quality and hazardous waste sites Industry: Monitoring wastewater influent and effluent Marine transportation: Checking bilge and ballast discharge Petroleum processing: Monitoring the efficiency of oil/water separation processes Oil depots: Monitoring the discharge produced when cleaning storage tanks Automotive: Monitoring waste-water discharge from service stations Quality Assurance: Measuring residual oil on textiles and metal parts.

All the right connections


Each unit is equipped with a printer port and an RS-232C port. Simply connect the OCMA-350 to your printer or PC for remote control of the unit and ready access to measurement data.

The OCMA-350 has various special features to assure accurate measurements.


Stable readout
The units data evaluation function analyzes the readings, determines when the value has stabilized, and displays that stable value.

Measurement of residual oil


The OCMA-350 makes it easy to measure residual oil on precleaned parts.
1

Choose a reasonably sized sample Measure out an appropriate amount of solvent, and immerse the parts in the solvent until all the residual oil has dissolved. Introduce the resulting solution to the measuring cell, and set the cell in place. Press the start button and wait for the results.

Self-monitoring
Messages on the LCD screen inform you of any electrical malfunctions, irregularities in measurement, and deterioration of parts, so that you can always be assured of proper functioning.

Simplified recordkeeping
The OCMA-350 keeps a record of the time and date of measurement along with each data set it records. When printing out, it provides you with both the time and the measurement, allowing for easy recordkeeping.

HORIBAs S-316 Solvent


The OCMA-350 uses the highly effective, environmentally-safe S-316 extraction solvent to extract the oil components from oily water samples, soil samples, or product surfaces. The extract is analyzed using IR absorbance, a non-dispersive infrared spectrophotometric technique which is specific to hydrocarbons such as oil. The OCMA-350 measures absorption in the 3.4 to 3.5 micrometer range. The two graphs at the right show the absorption spectra of (1) petroleum and (2) HORIBAs S316 solvent. All hydrocarbons, including oils, absorb infrared radiation at about 3.4 to 3.5 micrometers. As a result, the unit can measure any hydrocarbons in the extraction solvent quickly and accurately, with no distortion of values due to the presence of the solvent. HORIBAs S-316 Solvent can be recycled with the aid of the optional SR-300 Solvent Reclaimer. Recycling the solvent not only cuts your solvent costs, but also helps protect the environment.

100

A-Heavy Oil

Transmission(%)

80 60 40 20 0 1 2 3 4 5 6 7 8 9

B-Heavy Oil

C-Heavy Oil
10 11 12 13 14 15

(m)
100

Transmission(%)

80 60 40 20 0 1 2 3 4 5 6 7 8 9

S-316

10

11

12

13

14

15

(m)

Dimensional Outlines

Unit: mm (in)

Model SR-300 Solvent Reclaimer (optional)


Highly efficient, the SR-300 solvent reclaimer can reduce your per test solvent cost by up to 90%. This optional unit, designed especially for reclaiming HORIBAs S-316 solvent, features a double column of activated carbon and activated aluminum. It has a large filtering capacity, is easy to operate, and requires no electricity. External dimensions: 200 (W) X 200 (D) X 600 (H) mm 7.9 (W) X 7.9 (D) X 23.6 (H) in

WARM UP

ALARM

MEAS.
mg/l

200 (7.9)

mg/kg Abs. SET.

ESC.

SET. ENT.

ZERO SPAN CAL CAL

OIL CONTENT ANALYZER

OCMA-350

250 (9.8)

285 (11.0)

Specifications
Application: Oil contamination of fresh and salt water; soil analysis Principle: Solvent extraction, NDIR analysis (infrared spectroscopy) Detector: Pyroelectric sensor Cell: Quartz cell, cell length 20 mm Measuring range and unit: 0 to 200 mg/l, 0 to 1000 mg/kg, 0 to 1 Abs. Resolution: mg/l; 0 to 99.9 mg/ l; 0.1 mg /l 100 to 200 mg/l; 1 mg/l mg/kg; 0 to 9.99 mg/kg; 0.01 mg/kg 10.0 to 99.9 mg/kg; 0.1 mg/kg 100 to 1000 mg/kg; 1 mg/kg Abs; 0 to 1000 Abs; 0.001 Abs Repeatability: mg/l; 0 to 9.9 mg/l; 0.4 mg/l 1 digit 10.0 to 99.9 mg/l; 2.0 mg/l 1 digit 100 to 200 mg/l; 4 mg/l 1 digit Abs; 1% F.S. Measurement: Manually controlled Calibration: Automatic calibration after the calibration standard is introduced to the instrument Extraction solvent: HORIBA S-316 solvent Sample/solvent volume: Approx. 6.5 ml, ratio of sample to solvent is 1:1 Display: Measured value; 3 1/2digits LCD with back-light Message; Character display LCD with back-light (16 x 2 characters) Functions: Self diagnostics, Auto hold function, Calendar clock Output: RS-232C and centronics printer port Ambient temperature: 0 to 40C Power requirement: 100 to 240 V AC 10%, 50/60 Hz, 60 VA Dimensions: 200 (H) x 250 (W) x 285 (D) mm 7.9 (H) x 9.8 (W) x 11.0 (D) in Weight: Approx. 5 kg/11 lb

Horiba continues contributing to the preservation of the global environment through analysis and measuring technology.

Please read the operation manual before using this product to assure safe and proper handling of the product.

q The contents of this catalog are subject to change without prior notice, and without any subsequent liability to this company. q The color of the actual products may differ from the color pictured in this catalog due to printing limitations.

q HORIBA, Ltd. Head Office Miyanohigashi, Kisshoin Minami-ku, Kyoto, Japan Phone: 81 (75) 313-8123 Fax: 81 (75) 321-5725

Tokyo Sales Office 1-7-8 Higashi-Kanda Chiyoda-ku, Tokyo, Japan Phone: 81 (3) 3861-8231 Fax: 81 (3) 3861-8259

q HORIBA INSTRUMENTS INCORPORATED Ann Arbor Facility Irvine Facility 5900 Hines Drive 17671 Armstrong Avenue Ann Arbor, 48108 Irvine, CA 92614, U.S.A. U.S.A. Phone: 1 (949) 250-4811 Phone: 1 (734) 213-6555 Fax: 1 (949) 250-0924 Fax: 1 (734) 213-6525 q HORIBA EUROPE GmbH Head Office Hauptstrasse 108 65843 Sulzbach Germany Phone: 49 (6196) 6718-0 Fax: 49 (6196) 641198
Leichlingen Facility Julius-kronenberg Strasse D-42799 Leichlingen Germany Phone: 49 (2175) 8978-0 Fax: 49 (2175) 8978-50

Beijing Representative Office Room No. 410, No. 33 Cheng Fang Street, Xicheng District, Beijing P.R.O.C. 100032 T.O.D. Beijing-9503-316 Phone: 86 10-66077630 Fax: 86 10-66077554 q HORIBA / STEC INCORPORATED 1080 E. Duane, Suite. A Sunnyvale, CA 94086 U.S.A. Phone: 1 (408) 730-4772 Fax: 1 (408) 730-8975 HORIBA FRANCE Rue L. et A. Lumie `re Technoparc F-01630 St-Genis-Pouilly France Phone: 33 (4) 50-42-27-63 Fax: 33 (4) 50-42-07-74

q HORIBA KOREA Ltd. 112-6 Sogong-Dong Choong-ku, Seoul, Korea Phone: 82 (2) 753-7911 Fax: 82 (2) 756-4972

q HORIBA INSTRUMENTS Pte. LTD. 31 Kaki Bukit Road 3, #06-12 Techlink Singapore 417818 Phone: 65 745-8300 Fax: 65 745-8155

q HORIBA GmbH Kaplanstrasse 5 A-3430 Tulln, Austria Phone: 43 (2272) 65225 Fax: 43 (2272) 65230

HORIBA CZECHIA Organizachi slozka Praha Petrohradska 13 CZ-101 00 Praha 10, Czech Republic Phone: 420 (2) 717-464-80 Fax: 420 (2) 717-470-64

HORIBA SWEDEN Hertig Carlsvag 55-57 S-15138 So derta lje Sweden Phone: 46 (8) 550-80701 Fax: 46 (8) 550-80567

q HORIBA INSTRUMENTS LIMITED Kyoto Close Summerhouse Road Moulton Park, Northampton NN3 6FL, U.K. Phone: 44 (1604) 542500 Fax: 44 (1604) 542699

http://www.horiba.co.jp
Bulletin:HRE-1886C