0459 Z=730.714 Discharge=30 lit/sec Static water level=0.58m Dynamic water level=48.82 Pump position=60 Well diameter=12 Casing diameter=8'' Rising pipe Dia=4'' Length=69m Storage Reservoir Transmission pipe bore hole to storage reservoir Dia=PVC pn 10 DN100 Length=1223.54m X=784907.9711 Y=1098537.0656 Z=736.132 Pond bank height =1.75m Inlet to the chamber Z=736.132+1.75=737.882 masl
Design input Data for the bore hole a Storage reservoir base elevation Well head elevation Dynamic Water level Recommended pump position Recommended design discharge Static head (up to well head) Casing diameter Borehole depth
Data of feed pipelines: = 736.132-0.25=735.882 masl = 730.714masl = 48.82 m = 60m = 30 l/s (108m3/hr) = 0.58m = 8 (200mm) = 158m
Riser pipe type GS Dia. 100mm, L = 69m 2.1.1.2. Head loss calculation a) Riser pipe and head work pipe loss ( hrp ) PVC DN 100, L=69m, Q = 30 l/s Using Hazzen Williams formula
hrp = 10.7 (Q/C)1.85 x L / (D)4.87 Where C = coefficient of Roughness for GS pipe (120)
m3 sec
hrp = pipe friction loss L = Riser pipe and head work pipe length = 60+9=69m hrp = 10.7 (0.03/120)1.85 x 69/ (0.1)4.87 hrp = 11.86m . b) Dynamic Head Loss of Fittings ( hrp fit ) at well head
D e s c ri p ti o n 9 0
0
S M (
V M
C K
D Formu la (
b e n d s C h e c k v a l v e G a t e v a l v e
K * v2 / 2g
3.3498
3.821656
K * v2 / 2g
3.821656
1.4144
K * v2 / 2g
3.821656
0.2978
Where
Sub total of head losses for riser and head pipe works (hrpt ) hrpt = hrp + hrp fit = 11.86+ 5.0619= 16.9 m
c) Transmission main head losses Straight pipe head loss * From the well head to the junction Material-PVC pn 10 DN 100 mm L= 1223.54m Using Hazzen Williams formula hTL1 = 10.7 (Q/C)1.85 x L / (D)4.87 Where C = coefficient of Roughness for PVC pipe (150)
m3 sec
hTL1= pipe friction loss L = Straight pipe length hTL1 = 10.67 (0.03/120)1.85 x1223.54/ (0.1)4.87 hTL1 = 139.28 m Dynamic Head Loss of Fittings of transmission main pipe line (hTL fit )
C o ef fi ci e nt K
Desc ripti on
S M (
V M
F o r m u l a K * v
2
D (
3.821
1. 5
/ 2 g
2.233
head loss of fittings ( hTL fit) Sub total of head losses for transmission main (h TLT)
h TLT = hTL1 + hTL fit = 139.28+2.33 = 141.5 m Total System Head Losses ( hS ) Total System head loss consists fitting losses + pipe friction losses ht = hrpt + h TLT ht = 16.9 + 141.09 = 158.4m
The required pump power can be calculated from: PP = ( Q * HT ) /(102 * P) Where Q: discharge [l/s] HT: total head [mts]
P.
-The diesel engine capacity required to operate the submersible pump motor -Taking 0.9 motor efficiency the required power would be=115/0.9=127.77kw Considering the generator and the cable losses the engine shoud be -Rated for=127.77/0.9=141.97Kw -Taking the power factor of the generator as 0.8 =141.97/0.8=177.46 KVA -Taking derating factor of 0.94 the KVA rating of the gunset should be =177.46/0.94=188.79 KVA So a gunset with 190 KVA or the next available higher capacity generator should be selected.
Mete irrigation project electro mechanical input data Design input data for boreholes Well B X=786147 Y=1099137 Z=729.234 Discharge=30 lit/sec Artesian 8m above the ground Dynamic water level=3.9m Pump position=60 Well diameter=12'' Casing diameter=8'' Rising pipe Dia=4'' Length=69m Storage Reservoir Transmission pipe bore hole to storage reservoir Dia=PVC pn 10 DN100 Length=1352.99m X=784907.9711 Y=1098537.0656 Z=736.132 Pond bank height =1.75m Inlet to the chamber Z=736.132+1.75=737.882 masl
Design input Data for the bore hole b Storage reservoir base elevation Well head elevation Dynamic Water level Recommended pump position Recommended design discharge Static head (up to well head) Casing diameter Borehole depth
Data of feed pipelines: = 736.132-0.25=735.882 masl = 729.234masl = 3.9 m = 60m = 30 l/s (108m3/hr) = 0m = 8 (200mm) = 210m
L = Riser pipe and head work pipe length = 60+9=69m hrp = 10.7 (0.03/120)1.85 x 69/ (0.1)4.87 hrp = 11.86m . b) Dynamic Head Loss of Fittings ( hrp fit ) at well head
D e s c ri p ti o n 9 0
0
S M (
V M
C K
D Formu la (
b e n d s C h e c k v a l v e G a t e v a l v e
K * v2 / 2g
3.3498
3.821656
K * v2 / 2g
3.821656
1.4144
K * v2 / 2g
3.821656
0.2978
Where
Sub total of head losses for riser and head pipe works (hrpt ) hrpt = hrp + hrp fit = 11.86+ 5.069= 16.93 m
d) Transmission main head losses Straight pipe head loss * From the well head to the junction Material-PVC pn 10 DN 100 mm L= 1352.99m Using Hazzen Williams formula hTL1 = 10.7 (Q/C)1.85 x L / (D)4.87 Where C = coefficient of Roughness for PVC pipe (150)
m3 sec
hTL1= pipe friction loss L = Straight pipe length hTL1 = 10.67 (0.03/150)1.85 x1352.99/ (0.1)4.87 hTL1 = 154 m Dynamic Head Loss of Fittings of transmission main pipe line (hTL fit )
C o ef fi ci e nt K
Desc ripti on
S M (
V M
F o r m u l a K * v
2
D (
3.821
1. 5
/ 2 g
2.233
Sub total of head losses for transmission main (h TLT) h TLT = hTL1 + hTL fit = 154+2.233 = 156.233 m Total System Head Losses ( hS ) Total System head loss consists fitting losses + pipe friction losses ht = hrpt + h TLT ht = 16.93+ 156.233 = 173.18m
Where Q: discharge [l/s] HT: total head [mts] P. Overall efficiency (assumed 65%) PP = (30* 245) / 102 * 0.65 PP = 110.86 kW
-The diesel engine capacity required to operate the submersible pump motor -Taking 0.9 motor efficiency the required power would be=122/0.9=135.5 Kw Considering the generator and the cable losses the engine shoud be -Rated for=135.5 /0.9=150.6Kw -Taking the power factor of the generator as 0.8 =150.6/0.8=188.27 KVA -Taking derating factor of 0.94 the KVA rating of the gunset should be = 188.27 /0.94=200.28 KVA So a gunset with 201 KVA or the next available higher capacity generator should be selected.
Mete irrigation project electro mechanical input data Design input data for boreholes Well C X=786149 Y=1099719.5 Z=730 Discharge=30 lit/sec Artesian 8m above the ground Dynamic water level=3m Pump position=60 Well diameter=12'' Casing diameter=8'' Rising pipe Dia=4'' Length=69m Storage Reservoir Transmission pipe bore hole to storage reservoir Dia=PVC pn 10 DN100 Length=1682.5m X=786192 Y=1099533 Z=736.132 Pond bank height =1.75m Inlet to the chamber Z=736.132+1.75=737.882 masl
Design input Data for the bore hole c Storage reservoir base elevation Well head elevation Dynamic Water level Recommended pump position Recommended design discharge Static head (up to well head) Casing diameter Borehole depth
Data of feed pipelines: = 736.132-0.25=735.882 masl = 730masl =3m = 60m = 30 l/s (108m3/hr) = 0m = 8 (200mm) = 200m
L = Riser pipe and head work pipe length = 60+9=69m hrp = 10.7 (0.03/120)1.85 x 69/ (0.1)4.87 hrp = 11.86m . c) Dynamic Head Loss of Fittings ( hrp fit ) at well head
D e s c ri p ti o n 9 0
0
S M (
V M
C K
D Formu la (
b e n d s C h e c k v a l v e G a t e v a l v e
K * v2 / 2g
3.3498
3.821656
K * v2 / 2g
3.821656
1.4144
K * v2 / 2g
3.821656
0.2978
Where
Sub total of head losses for riser and head pipe works (hrpt ) hrpt = hrp + hrp fit = 11.86+ 5.069= 16.93 m
e) Transmission main head losses Straight pipe head loss * From the well head to the junction Material-PVC pn 10 DN 100 mm L= 1682.5m Using Hazzen Williams formula hTL1 = 10.7 (Q/C)1.85 x L / (D)4.87 Where C = coefficient of Roughness for PVC pipe (150)
m3 sec
hTL1= pipe friction loss L = Straight pipe length hTL1 = 10.67 (0.03/150)1.85 x1682.5/ (0.1)4.87 hTL1 = 191.53 m Dynamic Head Loss of Fittings of transmission main pipe line (hTL fit )
C o ef fi ci e nt K
Desc ripti on
S M (
V M
F o r m u l a K * v
2
D (
3.821
1. 5
/ 2 g
2.233
Sub total of head losses for transmission main (h TLT) h TLT = hTL1 + hTL fit = 191.53+2.233 = 193.7665 m Total System Head Losses ( hS ) Total System head loss consists fitting losses + pipe friction losses ht = hrpt + h TLT ht = 16.93+ 193.7665 = 210.6971m
Where Q: discharge [l/s] HT: total head [mts] P. Overall efficiency (assumed 65%) PP = (30* 280) / 102 * 0.65 PP = 126.697 kW
-The diesel engine capacity required to operate the submersible pump motor -Taking 0.9 motor efficiency the required power would be=140/0.9=155.5 Kw
Considering the generator and the cable losses the engine shoud be
-Rated for=155.5 /0.9=172.84Kw -Taking the power factor of the generator as 0.8 =172.84/0.8=216.04 KVA -Taking derating factor of 0.94 the KVA rating of the gunset should be =216.04 /0.94=229.84 KVA So a gunset with 230 KVA or the next available higher capacity generator should be selected.