Graphic Operator Interface

Low Light Reflection and Ultra High-brightness Model


Display on GP-3300U*

Display on a standard model*

AGP-3300U
Model Number: AGP-3300-U1-D24
* Display images when installed in well-lighted locations.

A New Solution from Pro-face for Applications Installed in Well-lighted Locations.


isibility Sharp V !

Reason

isibility Sharp V

Designed for Minimal Reflected Light


Re ectance greatly decreased
Sunlight

Reason

1,000 cd/m2 Ultra High-brightness TFT


candela (cd/m2)
1000

Brightness greatly increased

500 350

[ AGP-3300U]

[ Standard model ]

CG simulation

[ AGP-3300U]

External light is re ected!

[ Standard model ]

CG simulation

AGP-3300U AGP-3300T

GP-2300T

The anti-re ective design minimizes re ected light in well-lighted locations. The bene t is easy to read sharp and clear screens in di cult-to-view locations.

The 1,000 cd/m2 (measured on TFT color LCD) ultra high-brightness TFT features a long backlight lifetime of 75,000 hours. This reduces backlight maintanenance costs and service times.
* Use as directed in General Speci cations on the rear of this lea et.

www.profaceamerica.com

AGP-3300U-D24
Performance Speci cations
Display Type Display Colors Resolution Backlight Dot Pitch E ective Display Area Brightness Brightness Control Backlight Service Life Application Memory Backup Memory Variable Area Program Area Number of Steps TFT Color LCD (Ultra high-brightness) 65,536 colors (No blink)*1 16,384 colors (3-speed blink) 320 x 240 pixels (QVGA) CCFL (User nonreplaceable. Factory replacement required.) W0.36 x H0.36 mm [W0.01 x H0.01 in.] W117.2 x H88.4 mm [W4.16 x H3.48 in.] Voltage Endurance 1,000 cd/m2 (Measured on TFT Color LCD) 8 Levels (Adjusted with the touch panel) over 75,000 hrs. FLASH EPROM 6 MB *2 SRAM 320 KB (Lithium battery for backup memory) *3 SRAM 64 KB (Uses lithium battery) *3 FLASH EPROM 132 KB Equivalent to 15,000 steps Resistive Film (analog) 1,024 x 1,024 RS-232C/RS-422/RS-485*5, Asynchronous Transmission, Data Length: 7 bit/8 bit, Serial (COM1) Parity: None, Odd or Even, Stop Bit: 1 bit/2 bit, Data Transmission Speed: 2,400 bps to 115.2 Kbps, Connector: D-sub 9 pin(plug) RS-422/RS-485, Asynchronous Transmission, Data Length: 7 bit/8 bit, Parity: None, Odd or Even, Stop Bit: 1 bit/2 bit, Data Transmission Speed: 2,400 bps to 115.2 Kbps, 187.5 kbps(MPI), Connector: D-sub 9 pin(socket) IEEE802.3u, 10BASE-T/100BASE-TX, Connector: Modular Jack (RJ-45) x 1 Communication Expansion Unit x 1 Conforms to USB1.1. (TYPE-A conn.) x 1, Power Supply Voltage: DC5V5%, Output Current: 500 mA (max.), Communication Distance: 5 m (max.) Compact Flash Card Slot (TYPE-II) x 1 Noise Immunity Electrostatic Discharge Immunity Grounding Structure *7 External Dimensions Weight Approx. Cooling Method *4 Insulation Resistance Ambient Operating Temperature Storage Temperature Ambient Humidity Storage Humidity Pollution Degree Atmosphere Air Pressure Vibration Resistance (altitude range) Vibration Resistance International Safety Standards Conforming Standards Input Voltage Rated Voltage Allowable Voltage Drop Power Consumption

Speci cations
General Speci cations
,
(Under application)

EN 55011 Class A, EN 610000 - 6 - 2 DC24V DC19.2 to 28.8V 5 ms max. 26 W max. AC1,000V 20 mA for 1 minute (Between charging and FG terminals) DC500V 10 M (min.) (Between charging and FG terminals) 0 to 50 *6 C -20 to +60 C 10 to 90% RH (Wet bulb temperature: 39 max. - no condensation) C 10 to 90% RH (Wet bulb temperature: 39 max. - no condensation) C For use in Pollution Degree 2 environment Free of corrosive gases 800 to 1,114 hPa (2,000 meters max.) IEC/EN61131-2 compliant 5 to 9 Hz Single Amplitude 3.5 mm [0.14 in.] 9 to 150 Hz Fixed Acceleration: 9.8 m/s2 X, Y, Z Directions for 10 cycles (100 minutes) Noise Voltage: 1,000 Vp-p Pulse Duration: 1 s Rise Time: 1 ns (via noise simulator) Contact Discharge Method: 6 kV (IEC/EN61000-4-2 Level 3) Protective grounding:Grounding resistance of 100 , 2 mm2 or thicker wire, or your country's applicable standard. (Same for FG and SG terminals) IP65f (On the front panel when properly installed in an enclosure) W167.5 mm x H135 mm x D59.5 mm[W6.59 x H5.31 x D2.34 in.] 1.0 kg [2.2 lb] max. (unit only) Natural Air Circulation

*1 Changing the Colors setting to "65,536 colors" will disable the blinking feature on all screens in your project. If you wish to use the blinking feature, select 16,384 colors. *2 Capacity available for user application *3 A Lithium battery's service life is over 10 years at 40 or lower, over 4.1 years at 50 or lower, and C C over 1.5 years at 60 or lower. When used for backup, data can be detained for approximately 100 days C with a fully charged battery or approximately 6 days with a half-charged battery.

+ 0.04 -0

167.5[6.59]
135[5.31]

5[0.20]

8
123[4.84]

13[0.51]

29[1.14]

1 123.5 + 04.86 -[

Control Memory Interfaces

Touch Panel Type Touch Panel Resolution

Serial (COM2)

Ethernet (LAN) Communication Expansion Unit 1 USB CF Card

*4 The number of steps can be increased to 60,000 in the software. However, this reduces the internal memory capacity (for screen data) by 1MB. *5 RS-232C and RS-422/RS-485 are software switchable. *6 "Operating temperature" refers to the temperature inside the mounting enclosure and on the front panel. *7 The performance of the product cannot be guaranteed for every environment.

Supporting Screen Editor Software: GP-Pro EX V2.51 or later (For the detail on the upgrade from the previous version, please contact our sales o ce closest to your o ce.)

External Dimensions

155.5[6.12] 59.5[2.34]

Cable Attachment Dimensions

Panel Cutout
1 156 + 0[6.14 + 0.04 -0

Panel thickness 1.6[0.06] to 5.0[0.20]


Compatible panel cutout dimensions with previous models (156 x 123.5) GP-377 (R) / GP-230*

4R3 or le ss

1 2

9 5 6 4

Part Names

Unit: mm[in.]
2Touch Panel

11

24[0.94]

1 Display 4 6 8

10

10 11

3 Status LED 5 Power Plug Connector Serial Interface (COM1) 7 Serial Interface (COM2) Ethernet Interface (LAN) 9 Expansion Unit Interface USB Interface (Host) CF Card Cover (CF Card Interface, DIP Switches) CF Card Access LED

* Attaching a Protective Cover reduces the e ectiveness of preventing the re ection of external light. A Screen Protection Sheet is not supported with AGP-3300U. For details of other options and system design, refer to the GP-3000 Series Hardware Manual.

Save Today! Ask us about our rst time buyer Promotion


2009.Pro-face America. All rights reserved.

Screen & Logic Development Software

Ver.

2.7
May 2011

Provides easy video image handling

Supports new Pro-face products

New Tools for Developers

"Exceed the boundaries of traditional screen creation."


World Wide Support Allows for easy conversion of screen data assets

New possibilities with HMI and Industrial PCs

www.profaceamerica.com

Use the power of the Pro-face GP-Pro EX development software to create intuitive, user friendly operator interface projects fast
Easy Camera Integration adds to Safety, Security and Visibility
Industry
Semiconductor Water Treatment Transfer Electronics Machine Tools

Industry

Automobile

Food and Beverage

Pharmaceuticals

Medical Care

Packaging

Do you take extra time and additional work to investigate causes of downtime on site?
CameraViewer EX allows you to view live images or record and playback video for root cause analysis.
Camera-Viewer EX allows you to check, record and play videos on PC at office in real time from cameras connected to GP.

Does thethe setting adjustmentan inspection/vision Does setting adjustment of of an inspection camera require additional work?
In combination with a COGNEX In-Sight vision system *, the settings can be changed when watching images from the cameras on a GP unit on site.
* GP3000 Series supports In-Sight Micro series and In-Sight 5000 series.

Ethernet

The video is saved on PC HDD, enabling you to record a long time.

Configuration

Images

Office Even when an NG unit is detected in inspection, the inspection camera can be adjusted. You can also check the images from the camera on GP screen * *
* Only one screen is required to see images from up to 3 cameras. Up to 16 cameras can be connected to GP. * The display position (X/Y), exposure time, focuse, lighting and brightness can be specified on GP.

LAN

No need of HMI or PC dedicated to a camera on site. Only one


HMI integrates functions to display the video images of inspection and operate equipment. It also provides high maintenanceability.

Before Production site

Specific monitor or PC HMI

After
GP

* The purchase of the license for Camera-Viewer EX is required. * Only the built-in video input interface of the Multimedia Class is supported. * Real time checking may be a delay of about one second to display an image on PC at office.

* This is available for the models with Ethernet port except for GP-4104, GP-3200 and GP-3300 Rev.3 or lower.

Communicating with multiple devices on only one screen


Indirect Controller addressing allows the creation of a single screen to cycle through data from multiple connected devices.

Before
Each device required one screen for its operation.

After
Data from multiple devices can be displayed on the same screen even when switching the communications of the devices.

Screen for Device 1 Screen for Device 2 Screen for Device 3


Device 1 Device 2 Device 3

Device 1 Device 1 Device 2 Device 3

* Multiple communications to PLCs and inverters can be made as well. * For communications with multiple devices, the devices should be the same models of the same manufacturer.

Easy screen creation using data assets


Screen data used in large-size GP can be used in small-size GP.
GP3000 Series

Conversion log files shows more detailed infromation. It supports checking work of screen data after conversion.

Mark and Library screens created with GP-PRO/PB III can be converted.

GP4000 Series
GP-PRO/PB III

Data conversion GP-Pro EX GP-PRO/PB III

Data conversion GP-Pro EX

- Base Screen Number - Part Name - Allocation - What was converted

Mark and Library screens can be used in GP-Pro EX.


Mark Screen Library Screen

Data conversion log file

User-friendly for world wide deployment


Date format based on local setup allows alarms and sampling data in CSV format to be used without editing.
7 types of data formats such as mm/dd/yy
GP

Easy editing alarm messages in various languages, such as Japanese, English, Chinese, Korean, with Excel.

Output alarm or sampling data in CSV format

No edit required for the CSV file

Export Import
Easy editing with Excel by importing and exporting the data by languages

To overseas
Japan
CSV file PLC

Alarm Message
America

Excel

(using Text Table)

Communicating with Supporting Windows 7 multiple devices on only one screen


16bit and 32bit data can now be used within a single script, which reduces the number of scripts as well as development and project maintenance time Files and Folders can now be copied using a? script, making it possible for an operator to? retrieve Log Data without exposing the file?

Before
File Manager exposes all files on external storage to the operator

After
Single switch can be used to copy files fast without exposing any files to the operator

New Pro-face products to expand your applications.


N e w Pro d u c t :

Compact HMI with Ethernet port

The Ethernet multi-link function allows you to add GP-4104 as sub display without changing setting of machines.
Ethernet

N e w Pro d u c t :

LED Backlit HMI and IPC

Energy efficient LED backlit panels, reduce energy consumption and maintenance cost
HMI Standard and Multimedia: AGP3750-T1 -AF/-D24 AGP3650-T1-AF AGP3600-T1-AF/-D24

GP3000 Series

HMI+Control: AGP3600-T1-AF-CA1M/-FN1M/-D81C/K? AGP3600-T1-D24-CA1M/-FN1M/-D81C/K Industrial PC: PS3710A-T42 / PS3710A-T42-24V PS3711A-T42 / PS3711A-T42-24V

GP-4104 PLC

GP-4104

GP-4104

* Ethernet Multilink function allows one control device to communicate with one master unit and up to 16 slave units.

Useful features and related software to expand applications of GP-Pro EX


Program feature for reduction of burden on PLC memory such as jumping from one screen to another.
GP-Pro EX allows you to create logic programs which used to be done within the PLC. The logic programs can read and write the data of external connected devices.
Drag and Drop

Remote HMI control and monitoring in real time


Data Management Pro-Server EX collects operation data on PC and also transfers operating instructions such as recipes from PC to HMI.
PLC

PC

GP
PLC PLC

<Model: EX-SDV-V**> Remote Monitoring GP-Viewer EX allows you to view and take control of GP screen at site from remote locations to check production status.

PC

GP

* All models except for GP-410*, GP-33*0H, GP-3200 and ST3000 Series.

<Model: EX-VIEWER-LICENCE> * Licenses are required to use Pro-Server EX and GP-Viewer EX.

Downloadable for free from our website

GP-Pro EX Ver.2.7 <Model : EX-ED-V27 and EX-ED-V27-DVD>


>
OS (except for 64-bit OS) Windows 2000 (SP3 or later), Windows XP Home, Professional (any SP), Windows Vista Ultimate, Home, Premium, Business(any SP), Windows 7 Starter, Home Basic, Home Premium, Professional, Enterprise, Ultimate (all editions) Windows 7 / Vista : Pentium 4 1GHz or greater Other than Windows 7 / Vista : Pentium III 800MHz or greater (Pentium 4 1.3GHz or greater recommended) SVGA 800600 or better (256 colors or greater required) Windows 7 / Vista : 1GB or greater (2GB or greater recommended) Other than Windows Vista : 512MB or greater (1GB or greater recommended) 540MB or greater *Free space necessary for installation English/ Japanese/ Korean/ Chinese (simplified/traditional)/ German/ French/ Italian/ Spanish English / Japanese / Korean / Chinese (simplified / traditional) / German / French / Italian / Spanish *For languages other than English / Japanese, FEPs and fonts for these languages should be added. Those supported by OS described above.

Transfer Tool (Required for screen data transfer from a PC that does not have GP-Pro EX installed)
OS (except for 64-bit OS) Windows 2000 (SP3 or later), Windows XP Home, Professional (any SP), Windows Vista Ultimate, Home, Premium, Business(any SP), Windows 7 Starter, Home Basic, Home Premium, Professional, Enterprise, Ultimate (all editions) *For the installation of this product, administrator rights are required. Windows 7 / Vista : Pentium 4 1GHz or greater Other than Windows 7 / Vista : Pentium III 266MHz or greater Windows 7 / Vista : 1GB or greater (2GB or greater recommended) Other than Windows 7 / Vista : 128MB or greater (512MB or greater recommended) 133MB or greater *Free space necessary for installation
Mouse (absolutely necessary), CD-ROM drive (necessary only for software installation) and printer (supported by the OS above)

CPU Resolution Memory Hard Disk Space Language Software Menu* Languages that Hardware can Display FEP for Languages

CPU Memory Hard Disk Space Other

*A USB port or Ethernet port is required to transfer screens on a PC.

Camera-Viewer EX <Model :EXCAVELS>


OS (except for 64-bit OS) Windows XP (all editions, SP2 or later), Windows Vista (all editions, SP1 or later), Windows 7 (all editions), Windows Server 2003 (Standard Edition and Enterprise Edition, SP1 or later), Windows Server 2003 R2 (Standard Edition and Enterprise Edition, SP1 or later)

* These languages will be supported accordingly. For details, please contact our sales office in your region.

For operating environment for Pro-Server EX and GP-Viewer EX, visit our website.

www.profaceamerica.com
Global Network and Global Support
Warning HAZARD OF OPERATOR INJURY, OR UNINTENDED EQUIPMENT DAMAGE
Before operating any of these products, be sure to read all related manuals thoroughly. Failure to follow these instructions can result in death or serious injury, unintended equipment damage. For printing purposes, the colors in this catalog may differ from those of the actual unit. Actual user screens may differ from the screens shown here. All product names used in this catalog are the registered trademarks or trademarks of their respective companies. All information contained in this catalog is subject to change without notice.

Pro-face is a registered trademark of Digital Electronics Corporation in Japan, U.S.A., Canada, Europe and other areas and countries.

http://www.profaceamerica.com/otasuke/

Pro-face America 750 North Maple Road Saline, MI 48176 USA Tel: 734-429-4971 Toll Free: 800-289-9266 http://www.profaceamerica.com email: sales@profaceamerica.com
2011.05 Pro-face America. All rights reserved.

511288 +91 80 3066 7454/7456

http://www.profaceamerica.com

WI/WI1103-PROEXALL-01E05PFA

www.QuantumAutomation.com | (714) 854-0800


Operator Interface Touch Panels
The most practical touch panel now performs Remote Access and Control! With a Web browser on any PC, remote users can operate and monitor a local C-more HMI system from anywhere on the internet or on a local network.

#1 Value Added Reseller

The Productivity3000 automation controller offers you a more powerful industrial control solution that is easier to use and more cost effective than any control solution in the market.
LCD Display | USB Programming Port Ethernet Network Port | Ethernet Remote I/O Port USB Data Port | USB Local I/O Port RS232 and RS485 Ports

PACs & PLCs Operator Interface PC-Based Software Drives & Motion Motors & Gearboxes Panel Building Products Power Products Sensors & Safety Communications Relays & Timers Pneumatics & Process

Industrial Ethernet Switches Industrial Wireless & Cellular Communications Remote Automation Serial/USB/Fiber Optic Media Converters Industrial Video Servers Embedded Computing

Embedded Boards Design to Build Available Touch Panel Computers (TPC) Industrial Panel PCs (IPPC) Flat Panel Monitors (FPM) Fanless Box PCs (UNO)

Class 1, Div. 2 Industrial PCs Touch PCs & Flat Panel Monitors Operator Interface Touch Panels

InduSoft Web Studio v7.0 SCADA Software

Industrial AC Variable Speed Drives Up To 500hp WJ200 Series Inverters L300P Series Inverters SJ700 Series Inverters

Air-to-Air Cabinet Coolers Air-to-Water Cabinet Coolers Energy Efcient & UL Listed

Automation & Sensing Safety Products Switching & Controls

DC UPS with Battery Backup DIN Rail Power Supplies Surge Suppression & Filters Control Transformers General Purpose Transformers

Contact Quantum Automation Receive FREE catalogs and brochures or to place your purchase orders.

Corporate Headquarters: 4400 East La Palma Ave., Anaheim, CA. 92807 T (714) 854-0800 F (714) 854-0803 sales@quantumautomation.com

Authorized Value Added Reseller

Application experienced sales people West Coast inventory & 24 hour emergency support Local training & technical support

ur mission is to provide the most practical industrial control solutions at direct prices. We use our machine and process control applications experience to help you choose the most efcient control system for your needs. Our application engineers provide you with technical support and training, either at our place or yours. We look forward to developing a long lasting relationship with your company.

Brian Gallogly
Brian Gallogly, President

Value Added Services In-House, Online & On-Site Training On-Site Product Demonstrations 24 Hour Emergency Support Local Technical Support West Coast Inventory Product Kitting Material Usage Reports Upon Request Vendor Performance Metrics Available Same Price as AutomationDirect On-Site Project Help & Special Quotations Available Visit www.QuantumAutomation.com and click on Contact Us for the Region Sales Manager in your area.

Free Technical Support Our application experienced sales managers have been answering your toughest technical questions for 20 years. Call (714) 854-0800, e-mail Support@QuantumAutomation.com or visit www.TechCorner.QuantumAutomation.com for our online resource of technical articles and support links. Fast & Easy Ordering Its easy to buy from us: By phone, fax, online, e-mail, or in person. Phone: (714) 854-0800 Fax: (714) 854-0803 Online: www.Order.QuantumAutomation.com E-Mail: Sales@QuantumAutomation.com Headquarters: 4400 E. La Palma Ave., Anaheim, CA 92807

400+ Training Videos Online & In Our Training Room


200+ ONLINE VIDEOS AT WWW.LEARN.QUANTUMAUTOMATION.COM ADDITIONAL 200+ IN-HOUSE VIDEOS AT QUANTUM AUTOMATIONS CORPORATE HEADQUARTERS
FREE 1 DAY TRAINING WITH EQUIPMENT & VIDEOS
(Classes Available at Quantum Automations Headquarters in Anaheim, CA. Mon - Fri, 8am - 5pm)

PLC Basic Controls Analog I/O Productivity 3000 C-more HMI Click PLC Drives - Motors - Motion (VSD, Servo, & Stepper) Dataworx Data Collection

FREE IN-HOUSE CUSTOM TRAINING AVAILABLE Indusoft SCADA Software Conguration Programming Embedded Computers Using Linux or Windows XP Embedded Conguring Managed Ethernet Switches Integrating Video Encoders with Cameras & DVR Setup Setting-Up Cellular Networks Conguring Wireless Access Points, Bridges & Clients
For On-Site training at a location of your choice please call for pricing (714) 854-0800

Sign up at Learn.QuantumAutomation.com

Das könnte Ihnen auch gefallen