capacity, Dot Hill 2332 storage systems are used for vir tualized storage, file systems, Share Point, MS Exchange, MS SQL, just to name a few applications. The 2332 features a12-drive array housed in a 2 rackunit (2U) enclosure providing dual 1Gb iSCSI interfaces per controller to 3.5-inch SAS, SATA, or solid state drives. Up to seven JBOD expansion units can be easily added.
Eco-friendly EcoStor TM
The 2332 uses super capacitors instead of RAID cache batteries, providing infinite cache backup during a power loss while being environmentally friendly. Using super capacitors eliminates the need for battery maintenance, reducing the total cost of ownership.
2332 iSCSI
www.dothill.com
Product Family Product Type Chassis Configuration Disk Architecture Max Drives per Chassis Total Capacity Total Disks Mounting Options Max Number of Chassis Max Capacity per Chassis Data Management Services (DMS)
2002 Series RAID, JBOD 2U 3Gb SAS/3Gb SATA-II 12 drives 1.7TB/192TB (with expansion trays) 96 19 Rack, Telco Rack, Rack tray 8 (1 RAID and 7 JBOD) 24TB (2TB SATA-II drives) AssuredSnap, AssuredCopy
HIGH-AVAILABILITY FEATURES
Redundant Hot-Swap Controllers Redundant Hot-Swap Disk Redundant Hot-Swap Fans Redundant Hot-Swap Power Dual Power Cords Hot Standby Spare Automatic Failover Multi-Path Support Snapshot w/AssuredSnap Volume Copy with AssuredCopy Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
HOSTS
DRIVES
REGULATORY
Safety
UL 60950-1:2003 (USA) CAN/CSA-C22.2 No.60950-1-03 (Canada) EN 60950-1 :2001 + A11 (EU) IEC 60950-1 :2001 (International) CFR 47 Part 15 Subpart B (U.S.A. Class A) ICES-003:2004 Class A EN55022:2006 + A1:2007 Class A EN51000-3-2 2006 (Harmonics) EN61000-3-3 1995 (Amended by A1:2001 and A2:2005) (Flicker) EN55024 1998 (Amended by A1:2001 and A2:2003) (EU, Immunity) RoHS-5 Compliance , China RoHS, WEEE Australia/New Zealand, Canada, China (PRC), European Union (EU), Germany (GS Mark), Japan, United States
Electromagnetic Compatibility
RAID
Levels Supported RAID Type Cache Memory Cache Backup Virtual disks per System Volumes per virtual disk Volumes per System Mirrored Cache Super Capacitor Cache Backup Cache Backup to Flash
MANAGEMENT
Mini DB9 RS232, 10/100 Ethernet SNMP, SSL, SSH, SMTP WEB GUI, CLI RAIDar 2.0
SUPPORT
POWER REQUIREMENTS - AC
Input Power Requirements Max Input Power Heat Dissipation Voltage Max Input Power Heat Dissipation
POWER REQUIREMENTS - DC
Software Warranty Standard Hardware Warranty Environmental Monitoring Phone-home Capability Remote Diagnostics Non-disruptive Updates Non-disruptive Volume Expansion
90 days 3 years SNMP, CLI, RAIDar, SMTP Yes Yes Yes Yes for primary volumes and snapshot volumes
PHYSICAL
Height Depth (excluding cables) Width Chassis Weight Chassis (w/250GB drives) Weight
3.5 Inches / 8.9cm 23.7 Inches / 60.2cm 17.6 Inches / 44.7cm 44lbs. / 19.96kg 65lbs. / 29.48kg