Other Prepking products A) Offline Testing engine Use the offline Testing engine product to practice the questions in an exam environment. B) Study Guide (not available for all exams) Build a foundation of knowledge which will be useful also after passing the exam. Latest Version We are constantly reviewing our products. New material is added and old material is updated. Free updates are available for 90 days after the purchase. You should check your member zone at Prepking and update 3-4 days before the scheduled exam date. Here is the procedure to get the latest version: 1.Go towww.Prepking.com 2.Click on Member zone/Log in (right side) 3. Then click My Account 4.The latest versions of all purchased products are downloadable from here. Just click the links. For most updates,it is enough just to print the new questions at the end of the new version, not the whole document. Feedback If you spot a possible improvement then please let us know. We always interested in improving product quality. Feedback should be send to feedback@Prepking.com. You should include the following: Exam number, version, page number, question number, and your login ID. Our experts will answer your mail promptly. Copyright Each PDF file contains a unique serial number associated with your particular name and contact information for security purposes. So if we find out that a particular PDF file is being distributed by you, Prepking reserves the right to take legal action against you according to the International Copyright Laws. Explanations This product does not include explanations at the moment. If you are interested in providing explanations for this exam, please contact feedback@Prepking.com.

www.Prepking.com

1. The abbreviation "VSWR" stands for___. A. Variable Signal Wave Radio B. Voltage Strength Wire Ratio C. Very Strong Wave Radio D. Voltage Standing Wave Ratio Answer: D 2. What is the proper resistance of an ESD wrist strap? A. 1 ohm (O) B. 1 Mega ohm (MO) C. 10 O D. 1 MO Answer: B 3. In OMT, what view shows the RUs installed in the GSM cabinet? A. System View B. Radio view C. MO View D. Cabinet View Answer: D 4. What could a flashing green LED indicate in an MRU? A. Fault is localized B. Wait, activity in progress C. Battery Power depleted D. None of the above Answer: B 5. What common LED indicators are in the CDU, PSU, BFU, and dTRU? A. RBS Fault B. Operational C. Fault D. B and C Answer: D 6. How many T1s can one DXU-21 support? A. 1 B. 2 C. 3 D. 4
www.Prepking.com

Answer: D 7. An ESD wrist strap must always be used when handling or installing _____. A. a DXU B. printed circuit boards C. TRU/dTRU D. All of the above Answer: D 8. Bends to RF cables (coaxial) should be a minimum of ten (10) times the cable diameter. A. RLSTC:CELL=12002B, STATE=HALTED; B. RLSTC:SITE=12002,STATE=HALTED; C. RLSTP:CELL=12002B, HALTED; D. RLSTP:CELL=12002B, STATE=HALTED; Answer: A 9. The abbreviation "COD" stands for_____. A. Command Document B. Command Description C. Command On Demand D. None of the above Answer: B 10. In OMT, the System View shows: A. BSC, PCM link, Alarm Inlets, RBS, OMT, ISP, and ESB B. BTS, PCM link, Alarm Inlets, RBS, OMT, IDB, and ESI C. BSC, PCM link, Alarm Inlets, RBS, OMT, IDB, and ETS D. BSC, PCM link, Alarm Inlets, RBS, OMT, IDB, and ESB Answer: D 11. If VSWR supervision is disabled in the IDB, an alarm is sent to the BSC if the level reaches_____. A. 1.8 B. 2.2 C. 2.8 D. The alarm is not sent to the BSC Answer: D 12. What type of RU is a fan? A. MCRU B. DDMRU C. Subordinate
www.Prepking.com

D. Passive Answer: D 13. The abbreviation "TRU" stands for_____. A. Transmitter Unit B. Transceiver Unit C. Transmitting Replaceable Unit D. None of the above Answer: B 14. Why should you use the ESD wrist strap when handling RUs? A. to avoid an electrical shock to you B. To ensure good contact is made C. To avoid a static charge, which can damage electronic components D. Both B and C Answer: C 15. The abbreviation "CF" stands for: A. Central Frequency B. Cabinet Function C. Cellular Frequency D. Central Function Answer: D 16. Which of the following will cause a "VSWR" Limits Exceeded? A. Faulty TRU-CDU TX cable B. Loose PSU connection C. Loose G703 cable connection D. Unplugged optic cable Answer: A 17. What is the acceptable DC voltage range of the PSUs at 59 to 87 A. 25.4 to 27.7 B. 26.5 to 27.5 C. 26.9 to 27.7 D. 24.7 to 27.3 Answer: C 18. 32. The abbreviation "ACCU" stands for_____. A. Automatic Cable Connection Unit B. Automatic Cabinet Connection Unit
www.Prepking.com

C. Alternating Current Control Unit D. Automatic Transceiver Connection Converter Unit Answer: C 19. Which one of the following safety precautions should be used when working on a live cabinet? A. Have a licensed electrician on stand-by for power-related issues. B. Always power down site to minimize potential hazards. C. Energize all equipment before the power-up procedures are performed. D. Never touch AC voltage connections when working on energized equipment Answer: D 20. IDB parameters are set through what function of OMT? A. Modify IDB B. Install IDB C. Create IDB D. Save IDB Answer: C 21. It is possible to integrate a GSM RBS cabinet through OMT. A. True B. False Answer: B 22. What program (default) is used to read a DXU log once it is saved to your laptop? A. Microsoft WordPad B. Microsoft Excel C. WinFIOL D. Microsoft Access Answer: A 23. What is the maximum number of external alarms available in a DF? A. 8 B. 16 C. 24 D. 32 Answer: B 24. The process of defining alarms requires the DXU to be reset. A. True B. False Answer: B
www.Prepking.com

25. When inspecting equipment, you find damaged materials. Who do you contact? A. RBS Engineering B. RTAC C. Follow internal SOP or contact local support office D. Shipping Answer: C 26. When maintaining safety equipment, when should you inspect your safety equipment? A. Once a week B. Before and after each use C. If you think it is damaged D. When cleaning the safety equipment Answer: B 27. A_____ lit LED on the dTRU indicates that a fault is present. A. Yellow B. Red C. Green D. None of the above Answer: B 28. When defining RBS parameters, you must include all the following except: A. Site Specific parameters B. Environmental parameters C. T1 Line Build Out parameters D. PCM parameters Answer: B 29. If a three-sector site has six radios, how many cells/ Transceiver Groups does it have? A. 1/3 B. 1/2 C. 3/1 D. 3/2 Answer: C 30. When working with the RBS, you should remove_____. A. wrist watches B. rings C. bracelets D. All of the above
www.Prepking.com

Answer: D 31. To display software versions, OMT must be in what state? A. Init B. Connected (local IDB) C. Connected D. Remote Answer: C 32. The command RXBLI_____. A. prints the status of the cell B. blocks the managed object indicated C. ends the blocking of the indicated managed object D. prints the Alarm List Answer: B 33. The two main Replaceable Units in the RBS 2206 are_____. A. DXU-21 and dTRUs B. PSU-22 and PSU-21s C. CDU-Gs and CDU-Fs D. All of the above Answer: A 34. The abbreviation "PCM" stands for_____. A. Power Cabinet Manual B. Pulse Code Modulation C. Power Connection Mainframe D. Power Control Module Answer: B 35. You can reset MRUs manually or through OMT. A. True B. False Answer: A 36. Output Power is_____. A. configuration-dependent B. a dynamic function C. defaults to the lowest allowed level D. All of the above Answer: D
www.Prepking.com

37. The purpose of defining VSWR limits is_____. A. to eliminate default value B. change TRU shut-down level C. to set alarm values D. determine TRU overheating level Answer: C 38. The letter at the end of a command indicates the activity desired and stands for one of eight different possibilities. Four of these are: A. P/I/E/ and D B. D/C/I/ and E C. P/C/E/ and I D. D/E/I/ and X Answer: C 39. "POD" stands for Product Operational Document. A. True B. False Answer: B 40. What is the 4-bit binary representation for the hexadecimal number A? A. 0010 B. 1001 C. 1100 D. 1010 Answer: D 41. What must be done first before working with or near antennas, or breaking the transmit path at an existing site? A. Tell the NOC to switch off the transmitter. B. Climb the tower to check for loose connections. C. Ensure there is no RF Transmitting. D. Both A and C Answer: D 42. The DXU log can be saved in either .dbb or . dbt format. A. True B. False Answer: B 43. Commands relating to cells begin with what two letters?
www.Prepking.com

A. RL B. RX C. CL D. CE Answer: A 44. There are how many letters in a typical MML command? A. 4 B. 5 C. 6 D. 7 Answer: B 45. In OMT, the Radio (Hardware) View shows the TX and RX paths. A. True B. False Answer: A 46. Seasonal changes affect the transmission path. A. True B. False Answer: A 47. Which of the following commands provides a printout of the frequency hopping data for specific Managed Objects? A. RXHOP B. RXFHP C. RLHOP D. RXHDP Answer: D 48. What command would you use to halt the second sector on site number 12002? A. RLSTC:CELL=12002B, STATE=HALTED; B. RLSTC:SITE=12002, STATE=HALTED; C. RLSTP:CELL=12002B, HALTED; D. RLSTP:CELL=12002B, STATE=HALTED; Answer: A 49. A typical minimum configuration for an RBS 2698 is one remote unit (RRU) and one IXU. How many additional RRUs, maximum, can be cascaded from the main configuration? A. 2