Raychem's SFF fuses use a multilayer design sandwiching up to three fuse elements between layers of a matrixed glass ceramic material. This configuration has the benefit of supporting higher current ratings in a smaller package size, and providing better arc suppression characteristics.
Raychem's SFF fuses use a multilayer design sandwiching up to three fuse elements between layers of a matrixed glass ceramic material. This configuration has the benefit of supporting higher current ratings in a smaller package size, and providing better arc suppression characteristics.
Copyright:
Attribution Non-Commercial (BY-NC)
Verfügbare Formate
Als PDF, TXT herunterladen oder online auf Scribd lesen
Raychem's SFF fuses use a multilayer design sandwiching up to three fuse elements between layers of a matrixed glass ceramic material. This configuration has the benefit of supporting higher current ratings in a smaller package size, and providing better arc suppression characteristics.
Copyright:
Attribution Non-Commercial (BY-NC)
Verfügbare Formate
Als PDF, TXT herunterladen oder online auf Scribd lesen
Raychem Ci rcui t Protecti on Fast Acting Surface-mount Fuses Introduction Raychem Fast Acting Surface-Mount (SFF) fuses use a multilayer design which sandwiches up to three fuse elements between layers of a matrixed glass ceramic material. This configuration has the benefit of supporting higher current ratings in a smaller package size, and providing better arc suppression characteristics with less chance of a package breach exposing the surrounding environment to arcing fuse material when the fuse opens. Multi-layer Design Overview The multi-layer design of Raychem's SFF fuse family allows fuse elements to be stacked in parallel within a single device. The elements are embedded within the fuse body and surrounded on all sides by absorption material. Figure 1 compares the multi-layer design of Raychem's SFF fuses with typical single layer, glass coated designs. Figure 1. Multi-layer chip fuse vs single layer glass coated fuse -1- Glass/Ceramic Substrate Multiple Fuse Elements Substrate Material Single Fuse Element Glass Coating Multi-layer Design Single-layer Glass Coated Design The paralleled fuse elements provide very similar opening characteristics to single layer devices. Resistance imbalances between the elements are very small. Any difference in resistance will automatically be compensated by higher or lower current flow in the elements. Because the fuse elements are in parallel, their voltage drop must be the same. As a result, the higher resistance fuse element will carry proportionally less current. This, and the close physical proximity of the fuse elements within the construction, maintains a very consistent temperature on both elements. Therefore, premature opening of the fuse due to current imbalance between the fuse elements does not occur. When the fuse does open, one element will always open before the other. The small difference in time between the opening of each fuse element has no impact on the effectiveness of the fuse. Additionally, the absorption characteristics of the matrixed glass ceramic surrounding each element results in a very clean opening characteristic as presented below. The matrixed glass ceramic material of the fuse body contributes significantly to the fuse performance. This material very efficiently absorbs the vaporizing fuse material when the fuse opens. The multi-layer design surrounds each fuse element with the matrixed glass ceramic material providing a larger volume of absorption material to the vaporizing fuse element. The benefit of this combination of material and multiple layers is excellent absorption and arc suppression characteristics. - 2 - Arc Containment Another advantage of the multi-layer design is that the fuse elements are deeply buried within the fuse body. This reduces the chance that a high energy open will rupture the fuse surface and expose a high energy arc to the surrounding area, possibly even emitting molten metal. Figure 4 displays the exterior of Raychem s multi-layer fuse compared to glass coated designs after the fuse has blown. Figure 4. Post blow views of Raychems multi-layer fuse vs glass coated designs No Visible Failure or Breach Fuse Element Failure Zones Multi-layer Design Glass Coated Designs Higher Current Ratings In 0402(1005mm), 0603(1608mm) and 1206(3216mm) package sizes Raychems SFF fuses have some of the highest current levels commercially available today. The multi-layer design makes this possible. The ability to stack fuse elements in parallel allows greater current handling capacity within a given package size. Enhanced Arc Suppression Characteristics The multi-layer design has the benefit of exposing more fuse element surface area to the glass-ceramic absorption material. When the fuse elements open, there is more material for the vaporizing fuse metals to absorb into, resulting in a very efficient and effective quenching of the fuse arc. Figure 1 compared the multi-layer design of Raychems SFF fuses with standard glass coated designs. The glass coated designs rely on the coating on only one side of the fuse element to absorb the vaporizing fuse material when it opens. Therefore, there is much less absorption material available to absorb the fuse metals. The result can be prolonged arcing and possible coating breach. Figure 2 shows how the absorption characteristics of the two designs differ. The multi-layer design indicates a clean separation with the fuse element evenly diffusing into the surrounding ceramic substrate. In the glass coated design, theelement diffusion takes place in a small portion of the device and is only absorbed by the glass material directly above the area of failure. Figure 2. Blown element comparison between multi-layer and glass coated devices Single-layer Glass Coated Design Fault Zones Multi-layer Design The difference in the arc quenching performance can also be observed in the electrical signal characteristic at the time the fuse opens. Figure 3 presents opening characteristics of both designs at close to maximum ratings. The noisy tail displayed on the single- layer glass coated device indicates a sustained arc that slows the circuit disconnect in the presence of a fault. In this example, the arc is sustained for approximately 12ms, longer than the time it takes the fuse to begin opening under the fault current. The multi- layer design shows a very clean open characteristic indicating very efficient arc suppression. Figure 3. Electrical characteristic of multi-layer and glass coated designs at failure Single-layer Glass Coated Design Multi-layer Design Selecting Raychem Surface Mount Chip Fuses Fuse selection seems straightforward in that you pick one which has a current rating just a bit higher than your worstcase system operating current. Unfortunately, its not that simple. There are derating considerations for operating current and application temperature. Turn-on and other system operati ons (l i ke processor speed changes or motor start up) cause current surges or spikes that also require consideration when selecting a fuse. So selecting the right fuse for your application is not as simple as knowing the nominal current drawn by the system. However, by following the guideline presented in this paper, selecting the proper fuse does become a straightforward process. - 3 - Fuse Selection Flowchart The basic considerations for fuse selection are shown in the flowchart presented in Figure 1. Following this flow chart will help you select a fuse best suited for your application conditions. Figure 1. Fuse Selection Flowchart Temperature Derating A fuse is a temperature sensitive device. Therefore, operating temperature will have an effect on fuse performance and lifetime. Operating temperature should be taken into consideration when selecting the fuse current rating. The Thermal Derating Curve for Raychem surface mount chip fuses is presented in Figure 2. Use it to determine the derating percentage based on operating temperature and apply it to the derated system current. Apply Temperature Derating The minimum fuse current rating is determined by the following formula: Ifuse (Isys/0.75)/Ktemp Where: Ktemp is the % derating determined from the Thermal Derating Curve in Figure 2 Figure 2. Thermal Derating Curve If there are no pulse currents present in the application, then the fuse current rating may be selected. Finally, only the voltage rating must be reviewed for final fuse part number selection. Example 1Select a fuse for a system that draws 1.0 amp steady state during normal operation and operates at ambient temperatures up to 70C. I gnori ng for now the vol tage requirement, what is the minimum required current rating for the fuse in this application? Ifuse (Isys/0.75)/Ktemp Where: Isys = 1.0A Ktemp = 88% (determined from Figure 2) Ifuse (1.0A/0.75)/0.88 Ifuse 1.52A So a fuse with a current rating above 1.52A should be selected. Application Current Fuses require derating for both steady state and transient state conditions. The final current rating for the fuse used in any application will be a combination of both of these effects. It is easiest to analyze the derating requirements separately for the two conditions. Some applications may not require consideration of transient currents. Steady State Derating It is recommended that Raychem surface mount chip fuses not be operated at steady state currents greater than 75% of the nominal 25C current rating. Apply Standard Derating (75%) Ifuse Isys/0.75 Where: Ifuse is the rated data sheet current at 25C Isys is the nominal steady state system current Transient State or Pulse Derating The term Pulse is used to describe any type of transient current that may be applied to the fuse. Common examples of pulses are inrush currents observed at system turn-on, motor start-up currents and more extended duration peak currents observed during high speed processing activity in computing systems. These pulses have an effect on the fuse element because the transient heating they induce causes thermal cycling within the device. Over a large number of pulses, this can affect the life of the fuse. Therefore, the pulse energy and the number of times the fuse may be subjected to the pulse must be considered when selecting the proper fuse for the application. - 4 - The I 2 t parameter provides a measure of the fuses ability to withstand the energy of a pulse. By determining the I 2 t energy of the pulse, it can be compared to the fuses I 2 t curve to determine what the rated current of the fuse must be to help ensure reliable operation of the fuse. Determine Pulse Waveform Calculating Pulse I 2 tThe energy contained in a current pulse depends on the pulse waveforms shape, peak current and duration. The basic formula for I 2 t is: I 2 t = o t [A (t)] 2 dt Figure 3 presents the most common current waveforms and simplified equations for their I 2 t. In most systems, current waveforms could be approximated as either one of those on Figure 3 or their sequence. In case of such a sequence the resulting I 2 t is the sum of I 2 t of those individual waveforms. Figure 3. Waveform I 2 t Formulas Determine Pulse Waveform Once the I 2 t value for the application waveform has been determined, it must be derated based on the number of cycles expected over the system lifetime. Since the stress induced by the current pulse is mechanical in nature, the number of times the stress is applied has significant bearing on how much derating must be applied to the fuse rating. Figure 4 presents the current pulse derating curve for Raychem surface mount chip fuses up to 100,000 cycles. Pulse Temperature Derating Once the pul se cycl e derati ng has been appl i ed to the calculated I 2 t value, derating for operating temperature should be applied according to the thermal derating curve shown in Figure 2. Allowance for Circuit Variation Apply an additional 30% safety margin to tolerate the variances introduced by other components in the circuit. The derated I 2 t value can then be used to determine the rated fuse current. This is done by referring to the minimal fuse I 2 t vs clear time curves. The best way to explain how this is done is through an example. Example 2Select a 0603 size fuse that can handle a 1.0A steady state system current, is subjected to a capacitor charging turn-on pulse, peaks at 6 amps and lasts .005sec. The system runs at 24VDC, expects to see 100,000 cycles over its lifetime and normally operates at 70C. Step 1Apply the 75% steady state derating and the 88% thermal derating at 70C as determined in Example 1. Ifuse (Isys/0.75)/Ktemp Where: Isys = 1.0A Ktemp = 88% (determined from Figure 2) Ifuse (1.0A/0.75)/0.88 Ifuse 1.52A This is the minimum current rating the fuse must have to properly protect the system under steady state conditions only. Reviewing the datasheet indicates the 0603SFF200F/32 is the recommended device. (See tables in Appendix E.) Step 2Determine which pulse waveform in Figure 3 most cl osel y represents the appl i cati on and cal cul ate the waveforms I 2 t value. Since a capacitor must be charged every time the system is powered, the fuse will be subjected to a current pulse most like that of waveform #4 in Figure 3. Using the associated formula, the I 2 t value is calculated as: I 2 tpulse = (1/2)(6A) 2 x 0.005sec I 2 tpulse = 0.09 A 2 sec Figure 4. Raychem Surface Mount Chip Fuse Pulse Derating Curve - 5 - Step 3Apply Pulse Cycle DeratingDerate the I2t value based on the number of cycles required by the application. At 100,000 pulses, Figure 4 indicates a 40% derating of the I 2 t value is required. I 2 tdpulse = 0.09/0.4 A 2 sec I 2 tdpulse = 0.225 A 2 sec Where: I 2 tdpulse is the derated value for pulse waveforms. Step 4Apply Pulse Temperature DeratingDerate the I 2 t value based on system operating temperature. In this example apply 88% thermal derating at 70C from Figure 2. I 2 tdpulse = 0.225/0.88 A 2 sec I 2 tdpulse = 0.256 A 2 sec Step 5Apply Derating for Variance in the CircuitApply 30% safety margin (divide by 0.7) for variance introduced by other components in the application. I 2 tdpulse = 0.256/0.7 A 2 sec I 2 tdpulse = 0.365 A 2 sec Step 6Select Fuse Current Rating for Pulse Environment Determine which fuse has an I 2 t rating greater than I 2 tdpulse at .005sec. The minimum I 2 t versus clear time can be found in Figure 5 for Fast Acting Fuses and Figure 6 for Slow Blow Fuses. (Larger charts are available in Appendices A and C). Using Figure 5, the Fast Acting 0603SFF Family Minimum I 2 t vs Clear Time curves, it can be determined that Curve H has an I 2 t value greater than 0.365 A 2 sec at .005sec. This means that a 3.5A fuse, part number 0603SFF350F/32, would meet the pulse and cycle derating requirements for this application example. Refer to Appendix E for part number selection. Using the Slow Blow 0603SFS Family Minimum I 2 t vs Clear Time Curves in Figure 6, it can be determined that Curve C has an I 2 t value greater than 0.365 A 2 sec at .005sec. This means that a 2.0A fuse, 0603SFS200F/32, will meet this application example requirement. Refer to Appendix E for part number selection. Step 7Select Fuse Current RatingCompare the steady state current requirement from Step 1 to the current requirement for the pulse environment in Step 6 and determine which value is higher. The higher value will define the final fuse current rating. In this case for the steady state condition, a 2.0A Fast Acting Fuse from the 0603SFF Family is recommended. However, applying the pulse condition, a 3.5A Fast Acting Fuse from the 0603SFF Family or a 2.0A Slow Blow Fuse from the 0603SFS Family could be used. The 3.5A Fast Acting Fuse has a higher current rating than the 2.0A Fast Acting Fuse; therefore, the 2.0A Fast Acting Fuse can be eliminated as an option for this application example. Now, the choice is between the 3.5A Fast Acting Fuse and the 2.0A Slow Blow Fuse. Fast Acting Fuses open very quickly in response to an overcurrent condition and transient current spikes not part of their normal operation. Slow Blow Fuses have a delayed opening sustained in overcurrent conditions or expected pulsed currents. Since this is an application where the fuse will be subjected to a current pulse, a Slow Blow Fuse is a better choice. Step 8Check Voltage RatingThe system voltage is 24V. The 0603SFF350F/32 and 0603SFS200F/32 are rated for use at 32VDC. They both meet the voltage requirements. NOTE: The fuse selection method presented in this paper is intended as a guideline to determine the fuse most suitable for an application. We recommend testing the fuse in the actual application with the worst case scenario to confirm suitable performance. We also recommend verifying fuse clearing time to ensure that the right fuse is selected to provide the protection needed for the circuit and complies with required regulatory and safety standards. Visit our website at www.circuitprotection.com for the most up to date information. Figure 5. 0603SFF (Fast Actiing) Family Minimum I2t vs Clear Time Curves Figure 6. 0603SFS (Slow Blow) Family Minimum I2t vs Clear Time Curves * Please note clear time curves are minimum threshold, not typical. - 6 - Appendix A - T - Appendix B - 8 - Appendix C - 9 - Appendix D - 1u - Appendix E Typical Electrical Characteristics Max Interrupt Ratings 0603SFF (1608mm) Fast Acting Surface Mount Chip Fuses 0603SFF050F/32 0603SFF075F/32 0603SFF100F/32 0603SFF150F/32 0603SFF200F/32 0603SFF250F/32 0603SFF300F/32 0603SFF350F/32 0603SFF400F/32 0603SFF500F/32 0603SFF600F/24 0.50 0.75 1.00 1.50 2.00 2.50 3.00 3.50 4.00 5.00 6.00 0.485 0.254 0.131 0.059 0.044 0.032 0.025 0.024 0.018 0.013 0.010 32 32 32 32 32 32 32 32 32 32 24 50 50 50 35 35 35 35 35 35 35 35 * Measured at 10% of rated current and 25C Shape and Dimensions Inch (mm) Recommended Pad Layout Inch (mm) Typical Electrical Characteristics Max Interrupt Ratings 0603SFS (1608mm) Slow Blow Surface Mount Chip Fuses 0603SFS100F/32 0603SFS150F/32 0603SFS200F/32 0603SFS250F/32 0603SFS300F/32 0603SFS350F/32 0603SFS400F/32 0603SFS450F/32 0603SFS500F/32 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 0.200 0.100 0.052 0.041 0.031 0.021 0.017 0.015 0.013 0.09 0.18 0.82 0.63 0.87 1.20 2.30 2.70 3.20 32 32 32 32 32 32 32 32 32 * Measured at 10% of rated current and 25C Melting I 2 t at 0.001 sec clear time Shape and Dimensions Inch (mm) Recommended Pad Layout Inch (mm) Part Number Nominal I 2 t (A 2 sec) Voltage (V DC ) Current (A) NOTE: Additional sizes and current ratings are available. Go to www.circuitprotection.com or refer to the latest catalog. 40 40 40 40 40 40 40 40 40 Rated Current (A) Nominal Cold DCR ()* Raychem Circuit Protection Products 308 Constitution Drive, Building H Tel : (800) 227-7040, (650) 361-6900 www.circuitprotection.com Menlo Park, CA USA 94025-1164 Fax : (650) 361-4600 www.circuitprotection.com.hk (Chinese) www.tycoelectronics.com/japan/raychem (Japanese) Raychem, PolySwitch, SiBar, TE Logo and Tyco Electronics are trademarks. All other trademarks are trademarks of their respective owners. All information, including illustrations, is believed to be reliable. Users, however, should independently evaluate the suitability of each product for their application. Tyco Electronics makes no warranties as to the accuracy or completeness of the information, and disclaims any liability regarding its use. Tyco Electronics' only obligations are those in the Company's Standard Terms and Conditions of Sale for this product, and in no case will Tyco Electronics be liable for any incidental, indirect, or consequential damages arising from the sale, resale, use or misuse of the product. Specifications are subject to change without notice. In addition, Tyco Electronics reserves the right to make changes-without notification to Buyer-to materials or processing that do not affect compliance with any applicable specification. 2008 Tyco Electronics Corporation. All rights reserved. RCP0029E.0208 Part Number Rated Current (A) Nominal Cold DCR ()* Voltage (V DC ) Current (A)