Compact, lightweight and portable. A cost-effective solution for bringing ECG, pulse oximetry, noninvasive blood pressure, temperature, and respiration to hospitals, clinics, and private offices.
Features include:
Unique DOX
digital SpO2 technology for improved pulse recognition and artifact rejection.
507E/EP ScholarII
Technical Specifications
ECG Number of Leads: Lead Selection: Gain Selection: Frequency Response: Isolation: Sweep Speed: Electrosurgery Protection: Defibrillation Protection: Pacer Rejection: Gain: 3 I, II, III 0.5 mV, 1 mV, 2 mV, 4 mV, 8 mV full scale (all 2%) Diagnostic: 0.05 to 100 Hz (-3db) Monitor: 0.5 to 40 Hz (-3 db) Conforms to IEC 601-1 25, 50 mm/sec Yes Yes Yes Sensor Type: Audio: Range: Resolution: Accuracy: Method: High Saturation Alarm: Low Saturation Alarm: User Selectable Reusables: Finger, MultiSite, SHELL Disposables: Adult, Pediatric, Infant, Neonatal Beep with each detected pulse, pitch varies with oxygen saturation 1 to 99% 1% 2% (70 to 99%); 3% (50 to 70%) Dual wavelength LED Range: 70 to 99%, Off Range: 1 to 99%, Off
Heart Rate Display and Alarms Range: 20 to 300 BPM Accuracy: 1 BPM Alarm Limit Range: 80 to 250 (high); 20 to 150 (low) Alarm Indication: Audible, Visual Alarm Volume: Alarm Silence: Adjustable: 10 settings + Off, user selectable Yes, 2 minutes
External Power Supply Input Voltage: 90-260 VAC; 47-63 Hz Output Voltage: 16V DC Operating Environment Temperature: 15 to 40 C (59 to 104 F) Humidity: 15 to 90% (non-condensing) Storage Temperature: -5 to 50 C (23 to 122 F) Display Type: Number of Traces: Languages: System Outputs Digital: Analog Output: Trends Memory: Battery Type: Life: Recharge Time: Physical Properties Size: Weight: Classifications Type of Protection: Degree of Protection: Protection Against Liquids: LCD (main display) LED (green: SpO2%; red: Rate, Sys, Dia, Map) 2 maximum English, French, German, Spanish DB-9 (serial interface) BNC, 1V range 24 hours of tabular patient data at 3-minute NIBP interval and 1 minute other parameters Rechargeable lead acid 1 hour 6 hours to 100% capacity
Non-invasive Blood Pressure Technique: Automatic oscillometric upon inflation Max. Inflation Pressure: Adult 300mmHg; Neonate 150mmHg Measurement Cycle: < 40 sec. average (0 to 300mmHg: standard adult cuff) Automatic Measurement Cycles: 1, 2, 3, 5, 10, 15, 30 and 60 minutes; STAT pressure interval is 5 minutes Alarm Range: Systolic: Diastolic: Mean: High 70 to 250, Off 50 to 180, Off 70 to 200, Off Low Off, 50 to 150 Off, 15 to 50 Off, 25 to 125
Impedance Respiration Range: 0 to 150 breaths/minute Resolution: 1 breath/minute Accuracy: > of 2% or 1 breath/minute over full range Sensitivity: 0.3 to 10 ohms (Adult); 0.1 to 10 ohms (Neonate) Alarm Range: High: 6 to 150, Off; Low: 2 to 120, Off Temperature Range: 20 to 45 C (68 to 113 F); 0.5 (20 to 34 C); 0.2 C (34 to 41 C); 0.5 C (41to 45 C) 0.1 C or 0.1 F YSI-400 Series Range: 20 to 45 C (68 to 113 F) Range: 20 to 45 C (68 to 113 F)
Oxygen Saturation (SpO2) Averaging Time: Selectable 3 to 21 seconds Search Time: Selectable, 10 to 40 seconds Waveform: User Selectable
175614
Quality systems registered to ISO 9001 and CE self-marking per Annex II, Clause 3 of Council Directive No. 93/42/EEC concerning medical devices by TV Product Service GmbH, Munich. Specifications subject to change without notice. Manufactured in USA.