Beruflich Dokumente
Kultur Dokumente
Zhone 6742 CPE Firmware Upgrade via GUI DU Telecom Version 1.0
Confidential - Copyright Zhone Technologies, Inc. Material contained in this document may not be copied, reproduced, reduced to any electronic medium or machine readable form or otherwise duplicated and the information herein may not be used, disseminated or otherwise disclosed, except with the prior written consent of an authorized representative of Zhone Technologies, Inc. Zhone and the Zhone logo are registered trademarks, and all Zhone product names are trademarks of Zhone Technologies, Inc.
Revision History
File Name Zhone 6742 CPE Firmware Upgrade via GUI Rev 1-0.doc
Comment
INTRODUCTION
2 CPE FIRMWARE UPGRADE FOR EXISTING DEPLOYED AND IN-SERVICE CPES IN THE FIELD FROM B3 OR B5 RELEASE TO 102TUP3D0.BIN 3 CPE FIRMWARE UPGRADE FOR NEW CPES (NOT YET DEPLOYED NOR CONFIGURED) IN THE FIELD FROM B3 OR B5 RELEASE TO 102TUP3D0.BIN
11
1 Introduction
This document provides procedure to upgrade 6742 ADSL2+/VDSL2 CPE via GUI to software release 102TUP3D0.bin in the following two cases . a) Upgrade existing deployed and in-service CPEs in the field from b3 or b5 release to 102TUP3D0.bin. b) Upgrade new CPEs (not yet deployed nor configured) in the field from b3 or b5 release to 102TUP3D0.bin.
2 CPE Firmware upgrade for existing deployed and inservice CPEs in the field from b3 or b5 release to 102TUP3D0.bin
1. Open Web browser from PC and go to http://CPE_Management_IP, the following login page will appear. enter user name: Admin, pwd: Conf (previously admin/1234)
2. Check the current software version running on the CPE, go to the status menu: The current software version can be 1.02(TUP.0)b3 or 1.02(TUP.0)b5_0404
3. Click on Maintenance > Tools, select Firmware menu, specify the directory where the firmware 102TUP3D0.bin is stored on your PC and then click upload button.
4. Wait about 2 minutes for the upgrade process and CPE reboot to complete:
5. Once the upgrade process is completed successfully to 102TUP3D0.bin, check that the new version is showing on the status page:
6. Update old dial plan with new dial plan, Go to Voip SIP SIP Service Provider and click on Advanced button:
Update the old dial plan with the following new dial plan and click Apply button: ([*#]43@|#21@|*21<#:##>@|#67@|*67<#:##>@|#61@|*61<#:##>@|[*#]261@|[*#]40 @|*34*xxxx*[1-3]#@|#34*xxxx#@)
7. Update old TR069 server IP address with new TR069 IP address, Go to Advanced Remote MGMT TR069:
10
3 CPE Firmware upgrade for new CPEs (not yet deployed nor configured) in the field from b3 or b5 release to 102TUP3D0.bin
1. Open Web browser from PC and go to http://CPE_Management_IP, the following login page will appear. enter user name: Admin, pwd: Conf (previously admin/1234)
11
2. Check the current software version running on the CPE, go to the status menu: The current software version can be 1.02(TUP.0)b3 or 1.02(TUP.0)b5_0404
12
3. Click on Maintenance > Tools, select Firmware menu, specify the directory where the firmware 102TUP3D0.bin is stored on your PC and then click upload button.
13
4. Wait about 2 minutes for the upgrade process and CPE reboot to complete:
14
5. Once the upgrade process is completed successfully to 102TUP3D0.bin, check that the new version is showing on the status page:
15
6. Set the CPE to defaults, go to Maintenance ToolsConfiguration and click the Reset button:
16
17