Sie sind auf Seite 1von 164

GRUNDFOS CATALOGUE

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE


Custom-built pumps 50/60 Hz

Contents

Introduction
CR custom-built pumps Pumps for individual requirements 4 4

Pump
PN 25 and PN 40 pumps Measurement of inlet pressure Pumping of liquids down to 40 C Surface treatment CRN all-stainless steel pumps CR low NPSH Horizontal pumps Belt-driven pumps CR(I) deep-well pumps Pump rubber parts Empty chambers Bearing flange Support bearings Bearing material Pump head positions Customised nameplate Dry-running protection LiqTec Connections 39 39 39 40 41 41 42 45 47 48 48 48 50 50 50 50 50 50 51

Overview
6

Performance range
Performance range, CR Performance range, CRT(E) 8 9

Identification
Type keys 10

Applications
High-pressure applications Hot-water applications Applications involving temperature control Aggressive/hazardous liquids Hygienic applications Special installation requirements Special applications 11 12 13 14 15 16 17

Certificates
CR pumps with certificates 56

CRE pump solutions


CRE pump with extended functional module Customised CRE pump solutions 61 62

Motor
VIK-approved motors Tropicalised motors cURus-, UR- and CSA-approved motors Other motor approvals ATEX-approved pumps Special voltage Motor with multi-plug connection Motor with anti-condensation heater Motors with PTC sensors Motors with thermal switches Oversize motors Undersize motors Motor sizes available for pumps Alternative enclosure class (IP class) Alternative terminal box positions 4-pole motors Efficiency class 2 motors Other motor brands 18 18 18 18 19 19 20 21 22 22 23 24 25 26 26 26 26 26

How to read the curve charts


Guidelines to curve charts 69

Performance curves
CR deep-well Low-NPSH pumps CR pumps with 4-pole motor 70 71 87

Technical data
CR deep-well pumps 111

Technical data
CR low-NPSH pumps CR pumps with 4-pole motor 113 113

Shaft seals
Shaft seal arrangements Overview of shaft seals Shaft seal variants Double seal arrangements Back-to-back seal arrangement Tandem seal arrangement CR with air-cooled top Magnetic-drive pump (MAGdrive) 27 27 27 28 28 32 34 36

Technical data
CRN pumps with magnetic drive CRN pumps with magnetic drive 140 143

Motor data
Standard 2-pole motors for CR, CRI, CRN, 50 Hz Standard 4-pole motors for CR, CRI, CRN, 50 Hz Standard 2-pole motors for CR, CRI, CRN, 60 Hz Standard 4-pole motors for CR, CRI, CRN, 60 Hz 155 155 156 156

Contents

Pumped liquids
Pumped liquids List of pumped liquids 157 157

Further product documentation


WebCAPS WinCAPS 160 161

Introduction
This catalogue is a supplement to the these data booklets: CR, CRI, CRN, CRE, CRIE, CRNE CRT, CRTE CR, CRN high-pressure pumps. This catalogue gives an overview of some of the custom-built solutions offered by Grundfos. If the catalogue does not provide a solution to your specific pumping needs, please contact us with a detailed description of your problem, and we will get down to work - for you!

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Pumps for individual requirements


The CR pumps can be customised to meet individual requirements. This is due to the "mix and match" approach to customisation, where the many pump features and options are to be regarded as modules that can be combined to create the ideal pump for the job at hand. Motor options CR motors are available in many different configurations to meet the requirements presented by the power supply, the pump environment and/or the pumped liquid itself. Power supply systems vary in terms of both frequency and voltage, and required protection methods. Your environment may be explosive, very hot and/or very humid. Special conditions also apply at high altitudes. The pumped liquid can call for a special motor solution. High or low viscosities and/or high or low densities may require non-standard motor sizes. You may also need an explosion-proof variant. The installation site of the pump may require alternative positions of pump and motor parts, such as terminal box positions and vent screw positions. For further information, see Overview on page 6. Shaft seal options Extreme liquids sometimes call for extreme measures. High temperatures damage seal faces unless precautions are taken. Concern for safety can necessitate special measures for aggressive, toxic or flammable liquids. Liquids can be harmful to shaft seals because they crystallise, harden or are extremely abrasive. For further information, see Overview on page 6. Pump options The CR pump elements can handle the most demanding liquids and pressures and be adapted to suit many other requirements. Horizontal installation if height is a limitation. Poor inlet conditions mean that NPSH values must be adjusted to avoid cavitation. Very high pressures demand special solutions. Special surface treatments or certificates may be required. For further information, see Overview on page 6.

CR custom-built pumps
We offer a wide range of custom-built variants of the CR type range for a variety of demanding industrial applications. With these multistage in-line pumps, based on the wellknown CR type range, we meet the customers needs for pumps capable of handling special installation requirements and these liquids: high-temperature liquids crystallizing liquids high-viscosity liquids such as paints and varnishes aggressive liquids volatile liquids flammable liquids. Most of the pumps are available with either mainsoperated motors (CR, CRI, CRN and CRT) or electronically speed-controlled motors (CRE, CRIE, CRNE and CRTE). Custom-built pumps from CR 1s to CR 90 are available for these temperature ranges: Water-based liquids: 40 C to +180 C. Thermal oils: 20 C to +240 C. The below pump types are available as custom-built pumps.
Pump type CR(E) CRI(E) CRN(E) Available. 1s 1 3 5 10 15 20 32 45 64 90 120 150

Note: CRT(E) 2, 4, 8 and 16 are also available as custom-built pumps.

Introduction
Connection options Your chosen pump elements can be fitted with exactly the connection options you need. All standards are covered, and special connection variants are available for maximum compactness, high liquid pressures etc. For further information, see Overview on page 6. Features and benefits Custom-built CR pumps have the following features and benefits:

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Grundfos motor Grundfos motors are remarkably silent and highly efficient. Three-phase pumps from 1.1 to 75 kW have efficiency class 1 motors as standard. Grundfos motors are available with integrated frequency converter designed for speed-controlled operation. Shaft seal solutions The specially designed cartridge seal increases reliability, ensures safe handling and enables easy service and access. The cartridge shaft seal comes in a wide choice of materials. It is available in single and double seal arrangements and magnetic drive configurations. Connections The Grundfos CR pump can be connected to any system. Material options The Grundfos CR pump is available in four different material variants: Titanium CRT(E): Stainless steel AISI 316 CRN(E): Stainless steel AISI 304 CRI(E): Stainless steel AISI 304/cast iron. CR(E): Wide range of pump sizes The CR pump comes in 13 flow sizes and hundreds of pressure sizes, ensuring that you can always find exactly the right pump for the job. High-performance hydraulics Pump efficiency is maximised by the optimised hydraulics and carefully crafted production technology. Dry-running protection The patented Grundfos LiqTec system eliminates the risk of breakdowns due to dry running. If there is no liquid in the pump, the LiqTec will stop the pump immediately.

GR5357

Overview

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

4-pole motors

Explosion-proof motors

Anti-condensation Multi-plug heater connections

CSA/UL-approved motors

See page 26

See page 19

See page 21

See page 20

See page 18

Shaft seals

Rubber parts

Titanium

Non-cartridge solution

CR pumps with aircooled top

See page 27

See page 28

See page 27

See page 27

See page 34

CR high-pressure pumps

Horizontal mounting

All-stainless steel CR pumps

Certificates

Low temperature

See page 11 and 39

See page 16 and 42

See page 41

See page 56

See page 13 and 39

Oval flanges (CR)

Flanges (CR)

PJE connections (CRI, CRN)

Flanges (CRI, CRN)

Clamp connections (CRI, CRN)

See page 55

See page 55

See page 53

See page 55

See page 52

Overview

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

VIK-approved motors

Oversize or Motor protection undersize motors

Special voltage

Enclosure class

Terminal box positions

See page 18

See page 22

See page 23

See page 19

See page 26

See page 26

MAGdrive

Back-to-back seal

CR pump with pressure intensifier

CR pump with barrier fluid

Tandem seal

Dry-running protection

See page 36

See page 28

See page 30

See page 29

See page 32

See page 50

Alternative colour

Bearing flange

Pump rubber parts

CR low-NPSH pumps

CR deep-well pumps

Belt-driven CR pumps

Bearing materials

Surface treatment

See page 41

See page 48

See page 48

See page 12 and 41 See page 17 and 47 See page 16 and 45 See page 50

See page 40

Oval flanges (CRI, CRN)

TriClamp connections (CRN)

Union connections (CRI, CRN)

PJE connections (CRT)

Custom-built solutions

See page 55

See page 51

See page 55

See page 55

See page 55

Performance range
Performance range, CR
50 Hz
H [m]
400 300 200
CR 32 CRN 32 CR 150 CRN 150 CR 120 CRN 120

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

50 Hz

100 80 60 40 30 20 0.8 1 1 2 3 4 5 6 8 10 20 30 40 50 60 80 100 200


CR 1s CRI 1s CRN 1s CR 1 CRI 1 CRN 1 CR 3 CRI 3 CRN 3 CR 5 CRI 5 CRN 5 CR 10 CRI 10 CRN 10 CR 15 CRI 15 CRN 15 CR 20 CRI 20 CRN 20 CR 45 CRN 45 CR 90 CRN 90 CR 64 CRN 64

Eta [%]
80 60

Q [m/h]

20 0 0.8 1 1 2 3 4 5 6 8 10 20 30 40 50 60 80 100 200

High-pressure range

Q [m/h]

Note: CRE, CRIE, CRNE pumps are available up to 22 kW. 60 Hz


H [m]
400 300 200
CR 150 CRN 150

60 Hz

CR 120 CRN 120

100 80 60 40 30 20 0.8 1 1 2 3 4 5 6 8 10 20 30 40 50 60 80 100 200


CR 1s CRI 1s CRN 1s CR 1 CRI 1 CRN 1 CR 3 CRI 3 CRN 3 CR 5 CRI 5 CRN 5 CR 10 CRI 10 CRN 10 CR 15 CRI 15 CRN 15 CR 20 CRI 20 CRN 20 CR 32 CRN 32 CR 45 CRN 45 CR 64 CRN 64 CR 90 CRN 90

Eta [%]
80 60 40 20 0 0.8 1 1 2 3 4 5 6 8 10 20 30 40 50 60 80 100

Q [m/h]

200

High-pressure range

Q [m/h]

Note: CRE, CRIE, CRNE pumps are available up to 22 kW.

TM02 1530 4408

TM02 1192 4708

40

Performance range
Performance range, CRT(E)
50 Hz
H [m]
300

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

CRT
50 Hz

200

100 90 80 70 60 50 40 30

CRT 2

CRT 4

CRT 8

CRT 16

20 1 2 3 4 5 6 7 8 9 10 20 30 40

Q [m/h]

Note: CRTE pumps are available. 60 Hz


H [m]
300

CRT
60 Hz

200

100 90 80 70 60 50 40 30

CRT 2

CRT 4

CRT 8

CRT 16

20 1 2 3 4 5 6 7 8 9 10 20 30 40

Q [m/h]

Note: CRTE pumps are available.

TM03 3818 1106

TM03 3817 1106

Identification
Type keys
Pump
Example Type range: CR, CRI, CRN, CRT Pump with integrated frequency control Flow rate [m3/h] Undersize impeller (all impellers) CR 1s, CRI 1s, CRN 1s Number of impellers Number of reduced-diameter impellers CR(E), CRN(E) 32, 45, 64, 90, 120,150 Code for pump version Code for pipe connection Code for materials Code for rubber parts Code for shaft seal CR E 32 s -4 -2 -A -F -G -E -HQQE

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Key to codes
Code Description Pump version A Basic version B Oversize motor D Pump with pressure intensifier DW Deep-well pump with ejector E Pump with certificate F Pump for high temperatures (with air-cooled top) G Multi-E slave H Horizontal version HS High-pressure pump with high-speed MGE motor I Different pressure rating J Pump with a different maximum speed K Pump with low NPSH M Magnetic drive N With sensor P Undersize motor R Horizontal version with bearing bracket SF High-pressure pump V Multi-E master X Special version Pipe connection A Oval flange B NPT thread CA FlexiClamp CX Triclamp F DIN flange G ANSI flange J JIS flange N Changed diameter of ports P PJE coupling X Special version Materials A Basic version D Carbon-graphite filled PTFE (bearings) G Wetted parts EN 1.4401/AISI 316 GI All parts stainless steel, wetted parts EN 1.4401/AISI 316 I Wetted parts EN 1.4301/AISI 304 II All parts stainless steel, wetted parts EN 1.4301/AISI 304 K Bronze (bearings) S SiC bearings + PTFE neck rings X Special version Code for rubber parts in pump E EPDM F FXM (Fluoraz) K FFKM (Kalrez) V FKM (Viton) Shaft seal type designation A O-ring seal with fixed driver D Balanced O-ring seal H Balanced cartridge seal with O-ring K Type M as cartridge seal O Double seal, back-to-back P Double seal, tandem X Special version Seal face material B Carbon, synthetic resin-impregnated C Other types of carbon H Cemented tungsten carbide, embedded (hybrid) U Cemented tungsten carbide Q Silicon carbide X Other ceramics Secondary seal material (rubber parts) E EPDM F FXM (Fluoraz) K FFKM (Kalrez) V FKM (Viton)

Shaft seal
Example Shaft seal type designation Material of rotating seal face Material of stationary seal face Material of secondary seal (rubber parts) -H -Q -Q -E

10

Applications
High-pressure applications

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

2-pump solutions Our 2-pump solutions are divided into two groups based on pump size: CRN 3, 5, 10, 15, 20 SF CR(N) 32, 45, 64, 90, 120, 150.
GR7767 - TM02 8470 4004

Applications

Both solutions consist of two pumps in series. The first pump is a standard pump for feeding. The second pump is a high-pressure pump especially designed for high pressure. To minimise the pressure on the shaft seal, the direction of rotation on CR SF pumps is the opposite of that of standard pumps, and the chamber stack is turned upside down. Consequently, the pumped liquid flows in the opposite direction. Further documentation
Information about CR high-pressure pumps (standard documentation) Pumps with bearing flange Customised pump parts Special installation requirements E-pump solutions WebCAPS see page 160 48 18-65 16 61 160

Fig. 1 CR high-pressure pumps

Reference applications Filtration reverse osmosis cleaning and washing boiler-feed. Custom-built solutions High-pressure applications often expose pumps to a variety of extreme conditions, such as high inlet pressure, high operating pressure, frequent starts/stops and pressure pulsing. Overload of the pump may cause increased wear of pump parts, such as motor bearings and shaft seal, and thus reduce the pump life. To avoid unexpected breakdowns, we offer custombuilt solutions designed to meet your needs! High-pressure handling We offer high-pressure pumps specially designed to cope with pressures up to 50 bar at max. +120 C. When necessary, CR high-pressure pumps are fitted with a bearing flange. A bearing flange is an additional flange with an oversize ball bearing designed to absorb axial forces in both directions. CR high-pressure pumps come in two variants: as a single-pump solution or as a 2-pump solution. Single-pump solutions are used for flow rates up to 5 m3/h. The 2-pump solution is used for flow rates above 5 m3/h. Single-pump solution Our single-pump solutions include the pump types CRNE 1 HS and CRNE 3 HS. CRNE HS pumps are fitted with a high-speed motor with integrated frequency converter. To minimise the pressure on the shaft seal, the direction of rotation is the opposite of that of standard pumps, and the chamber stack is turned up-side down. Consequently, the pumped liquid flows in the opposite direction.

Supplementary Grundfos pumps For pressures above 50 bar, we recommend Grundfos BM modules or Grundfos BME, BMET pumps. For further information about BM modules and BME, BMET pumps, see page 160.

11

Applications
Applications

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Hot-water applications
GR5228 - GR7767 - TM02 8470 4004

Applications involving poor inlet conditions Cavitation is often a problem in applications where pumps have to cope with the combination of high liquid temperatures, poor inlet pressure and/or high flow rate. Low-NPSH pumps eliminate the risk of cavitation and ensure a stable and reliable operation. The CR low-NPSH pump is a pump with a special first stage design that reduces the pumps NPSH value and prevents erosion and destruction of the pump, pipework and valves. For further information about NPSH and the calculation of NPSH-value, see these data booklets: CR, CRI, CRN, CRE, CRIE, CRNE CR, CRN high pressure CRT, CRTE. High-temperature applications The pumping of hot liquids demands much of pump parts, such as the shaft seal and rubber parts. To ensure a reliable and stable production, we offer CR pumps with an air-cooled top. A CR pump with an air-cooled top has a standard mechanical shaft seal handling liquid temperatures up to +180 C at 25 bar without external cooling. At the same time the pump delivers a high pressure. As the name implies, the pump is fitted with a special aircooled shaft seal chamber generating the same insulation effects as that of a vacuum flask. Further documentation
Information about CR low-NPSH pumps CR pumps with air-cooled top Pumps with bearing flange CR pumps with under-/oversize motor Customised pump parts Special installation requirements E-pump solutions WebCAPS see page 41 34 48 23 18-65 16 61 160

Fig. 2 CR pumps for hot-water applications

Reference applications Boiler feeding applications involving poor inlet/suction conditions cleaning and washing applications high-temperature applications. Custom-built solutions Hot-water applications often expose pumps to a variety of extreme conditions, such as high temperatures, long operating hours, frequent starts/stops, pressure pulsing, poor inlet conditions and high inlet pressure. Such conditions may result in cavitation and/or cause increased wear of pump parts, for instance motor bearings and shaft seal, and thus reduce the pump life. To avoid breakdowns, we offer custom-built solutions designed to meet your needs! We provide solutions for applications involving special requirements: steady steam production poor inlet conditions high temperature, etc. Steady steam production To ensure a steady steam production and a constant water level in the boiler tank, we recommend speedcontrolled pumps. Why speed-controlled pumps are recommended: The reaction to changes in the steam consumption is faster compared with mains-operated pumps. The water level in the boiler feed tank is kept stable. The installation costs are lower compared to systems with mains-operated pumps and valves.

Condensate Controller

10 bar +170 C Boiler


TM03 2615 4605

Burner

Fig. 3 Boiler-feed application with speed-controlled pump

12

Applications
Applications involving temperature control

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Pumping of high-temperature liquids The pumping of hot liquids demands much of pump parts, such as shaft seals and rubber parts. Examples of such liquids: water-based liquids up to +180 C at PN 25 thermal oils up to +240 C at PN 16. To ensure a reliable and stable production, we offer CR pumps with an air-cooled top and special rubber parts. A CR pump with an air-cooled top is a pump which can handle high temperatures and deliver a high pressure. The pump is fitted with a special air-cooled shaft seal chamber generating the same insulation effects as that of a vacuum flask. Pumping of high-viscous liquids In applications where high-viscous liquids are pumped, precautions must be taken to ensure that the motor of the pump is not overloaded, and that the pump performance is not reduced too much. The viscosity of a pumped liquid depends strongly on the liquid temperature. To ensure a stable and reliable operation, we offer CR pumps with oversize motors. Further documentation
Information about ATEX-approved pumps CR pumps with air-cooled top Pump rubber parts CR pumps with oversize motor Customised pump parts Special installation requirements E-pump solutions WebCAPS see page 19 34 48 23 18-65 16 61 160

Applications

Fig. 4 CRE, CRIE, CRNE pumps with sensor

Reference applications Cooling systems: Electronic data processing laser equipment medical equipment industrial cooling and freezing processes, etc. Temperature-control systems: Casting and moulding tools oil processing, etc. Custom-built solutions To ensure a safe and reliable operation in applications involving temperature control, we offer custom-built solutions designed to meet your needs! We provide solutions for applications involving pumping of the following liquids: liquids at temperatures down to 40 C high-temperature liquids high-viscous liquids, etc. Pumping of liquids down to 40 C In applications where liquids are pumped at temperatures down to 40 C, it is crucial for a successful production that pump parts are of the right materials and dimensions. At such low temperatures, the selection of wrong materials and dimensions may cause deformation because of thermal expansion, and eventually stoppage of operation. For low-temperature liquids below 20 C, we recommend CRN pumps.

TM02 7397 3403

13

Applications
Applications

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Aggressive/hazardous liquids

Pumps with back-to-back seal arrangement We recommend pumps with back-to-back seal arrangements for toxic, aggressive or flammable liquids. Pumps with back-to-back seal arrangements are connected to a pressure intensifier preventing leakage from the pump to the atmosphere side. MAGdrive pumps We recommend pumps with magnetic drive (MAGdrive) for toxic and hazardous liquids. The MAGdrive pump is a hermetically sealed pump. In the MAGdrive pump, the power from the motor is transmitted to the pump shaft by means of magnetic force instead of a traditional coupling. The motor shaft and the pump shaft are hermetically separated from each other. ATEX-approved pumps ATEX-approved pumps are recommended for potentially explosive atmospheres. Explosive atmospheres consist of air and combustible material such as gases, vapours, mists or dusts in which the explosion spreads after ignition. We offer ATEX-approved pumps with these classifications: 2G EExe II T3 2G EExd IIB T4 2G EExd IIC T4 2G EExde IIB T4 2G EExde IIC T4 EEx 2D T125 EEx 3D T125 . Electropolished pumps Electropolished pumps are recommended for use in applications with strict requirements concerning corrosion and cleanability. We offer electropolished pumps in all CRN pump sizes. Further documentation
Information about CR pumps with back-to-back seal arrangement CR pumps with tandem seal arrangement Pumps with magnetic drive (MAGdrive) ATEX-approved pumps Customised pump parts Special installation requirements E-pump solutions WebCAPS see page 28 32 36 19 18-65 16 61 160

Fig. 5 CR pumps for aggressive/hazardous liquids

Reference applications Chemical industry pharmaceutical industry refineries petrochemical industry distilling plants paint industry mining. Custom-built solutions In industries where pumping of dangerous and aggressive liquids is an integrated part of the daily production, safety is top priority. Leaking pumps pose a danger to the environment. To prevent breakdowns, we offer custom-built solutions designed to meet your needs! We provide solutions for the following liquids: aggressive and abrasive liquids toxic and hazardous liquids flammable liquids odorous liquids. To ensure a safe handling of the above liquids, we offer the following pumps: pumps with tandem seal arrangement and flushing pumps with back-to-back seal arrangement and pressure intensifier pumps with magnetic drive (MAGdrive) pumps with ATEX approval. Pumps with tandem seal arrangement Pumps with tandem seal arrangements connected to a flushing device are recommended for crystallizing, hardening or sticky liquids. If the primary seal leaks, the leaking liquid will be flushed away by a flushing liquid.

14

GR5954 - GR7369 - GR5216

Applications
Hygienic applications
TM02 1808 2001 - GR7375 - TM02 8470 4004

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Furthermore, we offer a wide variety of connections such as TriClamp connections specially designed for pharmaceutical, food and beverage industries. For further information about TriClamp connections, see page 51. We offer the following pumps: cleaned and dried pumps mechanically or electro-polished pumps. Electro-polished pumps have a higher corrosion resistance than non-polished pumps. Cleanability In secondary hygienic applications, it is extremely important to clean the pumps sufficiently to prevent deposits from contaminating the pumped liquid. For secondary hygienic applications we recommend CRN(E) pumps which have all pump parts in stainless steel. As the surface and properties of the metal is not affected by cleaning agents, stainless steel is the ideal solution. ATEX-approved pumps ATEX-approved pumps are recommended for potentially explosive atmospheres. Explosive atmospheres consist of air and combustible material such as gases, vapours, mists or dusts in which the explosion spreads after ignition. Further documentation
Information about Cleaned and dried CR pumps Electro-polished CR pumps Stainless steel CRN pumps ATEX-approved pumps Customised pump parts Special installation requirements E-pump solutions WebCAPS see page 40 40 41 19 18-65 16 61 160

Applications

Fig. 6 CR pumps for hygienic applications

CR pumps are not designed for the pumping of hygienic and sterile liquids, but their construction and the choice of materials make them an ideal solution for secondary processes in hygienic applications. Reference applications Pharmaceutical industries biotechnological industries electronics industries food and beverage industries process industries. Custom-built solutions In hygienic industries, pumps must meet strict requirements on design, materials, surface quality, cleanability, etc. To ensure a hygienic and reliable production, we offer custom-built solutions specially designed to meet your requirements! We provide solutions for applications involving special requirements to hygienic design and cleanability. Hygienic design The surface quality of pump parts is of utmost importance - both for corrosion resistance and microbial adhesion and growth. To meet the strict hygienic requirements to material and surface quality in secondary hygienic processes, we offer electro-polished stainless steel CRN pumps with the following surface quality:
Pump type CRN 1s, 1, 3, 5, 10, 15, 20 CRN 32, 45, 64, 90 Available Cast stainless steel parts Stainless steel plate parts Surface quality Ra 0.8 m Ra 10-15 m Ra 0.8 m

Supplementary Grundfos pumps If sanitary pumps with a hygienic design are required, we recommend the following Grundfos sanitary pump types: F&B-HYGIA Euro-HYGIA Contra Sipla. Most of the Grundfos sanitary pumps comply with the QHD, EHEDG and 3-A sanitary standards. For further information, see page 160.

15

Applications
Applications

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Special installation requirements

If the chamber stack and staybolts are stressed by repeated swings during an earthquake, they may break and cause stoppage of operation.
GR5886 - GR5379 - GR5887

For earthquake-prone areas and in mobile systems, we recommend CRN pumps, as stainless steel is more ductile than cast iron. Belt-driven pumps Belt-driven pumps are often selected in the following cases: non-electrically driven applications for instance air-, solar-, wind-, diesel- and pneumatically driven applications installations requiring an alternative supply, for instance firefighting systems and emergency pumps. The construction of belt-driven pumps is like that of electrically driven pumps, but belt-driven pumps have a pulley and belt connected to a combustion motor or other device. Pumps with alternative mounting For installations with limited access and space, we offer pumps with alternative mounting of pump parts such as terminal box and vent screw. Certificates, approvals and reports We offer custom-built pumps with a wide variety of certificates and approvals. Examples: Inspection certificate 3.1C - Lloyds Register of Shipping (LRS) - Det Norske Veritas (DNV) ATEX-, VIK-, UL-approvals Duty-point verification report Vibration test report. Further documentation
Information about Horizontally mounted CR pumps Belt-driven CR pumps Stainless steel CRN pumps Pump parts designed to match your needs CR pumps with certificates E-pump solutions WebCAPS see page 42 45 41 18-65 56 61 160

Fig. 7 CR pumps for special installations

Reference applications Places with limited access and space ships mobile applications fire protection earthquake-prone areas applications in remote areas. Custom-built solutions Due to safety, location and arrangement requirements some installations require pumps of another design than traditional vertical pumps. To meet special installation requirements, we offer custom-built solutions designed to meet your needs! We provide solutions for the following pump types: horizontally mounted pumps belt-driven pumps pumps with alternative mounting, etc. Horizontally mounted pumps Horizontally mounted pumps are often chosen in the following cases: installations with limited access and space, for instance cabinets and compact systems earthquake-prone areas mobile systems, for instance ships and vehicles. For installations with limited height, we recommend horizontally mounted pumps. For earthquake-prone areas, we recommend horizontally mounted pumps to lower the centre of gravity and thus minimise swings during an earthquake. See the example in fig. 8.

Supplementary Grundfos pumps For installations with special requirements to a compact design, we recommend CH, CHI pumps or BM booster modules. For further information, see page 160.

Fig. 8 Vibrations of pumps in earthquake-prone areas

16

TM03 2645 4705

Applications
Special applications
GR7369 -TM02 8470 - TM02 1808

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Pumping of liquids down to 40 C In applications with liquid temperatures down to 40 C, the material of shaft seal faces, the dimensions of the neck ring and other factors must meet high requirements. At such low temperatures, the selection of wrong materials and dimensions may cause deformation because of thermal expansion, and eventually stoppage of operation. For liquids below 20 C, we recommend CRN pumps. Deep-well pumping in small water supply systems Water is pumped from depths down to 90 metres. The system consists of a dry-mounted CR pump connected to a submerged ejector. Pumps operating under special conditions Installations at high altitudes (above 1000 metres) applications with low, high or fluctuating ambient temperatures the pumping of high-viscous/-density liquids. In such cases, the motor may be overloaded and an oversize motor may be required. Special requirements We offer custom-built pumps meeting special requirements as to approvals, voltage, frequency, etc. Further documentation
Information about CR pumps for cooling applications CR pumps for deep-well pumping CR pumps with under-/oversize motors Pump parts designed to match your needs Special installation requirements E-pump solutions CR pumps with certificates WebCAPS see page 39 47 23 18-65 16 61 56 160

Applications

Fig. 9 CRT, CRNE and CRN pumps

Reference applications Off-shore and maritime applications cooling applications deep-well pumping systems pumps operating under special conditions. Custom-built solutions We offer custom-built solutions for a number of applications not mentioned on the previous pages. Examples: Off-shore and maritime applications pumping of liquids down to 40 C deep-well pumping in small water supply systems special conditions special requirements as to approvals, voltage, frequency. To ensure a stable and reliable operation, we offer custom-built solutions designed to meet your needs! Off-shore and maritime applications In off-shore and maritime applications, pumps must meet stringent requirements to reliability in connection with for instance cooling, firefighting, cleaning and desaliniation systems. Pumps are often installed in a corrosive environment. We offer custom-built pumps with a wide variety of 3.1C inspection certificates, such as Lloyds Register of Shipping (LRS) and Det Norske Veritas (DNV). For further information, see page 56. Furthermore, we offer custom-built pumps with a wide variety of materials, connections, enclosure classes, etc. For the pumping of seawater, we recommend CRT(E) pumps which have all pump parts in titanium. As its corrosion resistance is not affected by seawater, titanium is the ideal solution.

Supplementary Grundfos pumps If the suction head exceeds 90 metres, we recommend Grundfos SP and SQ submersible pumps. For further information about SP and SQ pumps, see page 160.

17

Motor
The Grundfos standard range of motors meets a wide variety of application demands. For special applications or operating conditions, we offer various custom-built solutions: a wide range of motor approvals motors with special voltage motors with anti-condensation heater motors with Harting 10-pin multi-plug connection motors with built-in PTC sensor

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Tropicalised motors
A tropicalised motor does not contain paper, wood or similar materials containing wood pulp. Grundfos defines a tropicalised motor as a motor which fulfils the climate group World-Wide in DIN/IEC 7212-1 and has the following characteristics: enamel covered windings double winding impregnation double winding insulation FPM V-ring terminal board made of polyester liquid sealing between frame and flange/end shield all outside screws made of stainless steel 30 m paint layer on aluminium stator housings 120 m paint layer on cast iron stator housings heating element.

Motor

motors with built-in thermal switch undersize and oversize motors motors with alternative enclosure class, etc.

VIK-approved motors
VIK-approved motors are recommended for use in industrial climates where aggressive gasses and/or aggressive vapours, etc., are likely to occur. The VIK standard apply to three-phase mains-operated motors and three-phase motors connected to a frequency converter. We offer VIK-approved motors from 0.37 to 75 kW in accordance with the requirements of the German industrial standard, Verband der Industriellen Energie- und Kraftwirtschaft. To comply with the standard, VIK-approved motors must meet these requirements: Group II, Category 2, version EEx e or EEx d, temperature class T3 in the ATEX directive. In case of doubt, consult the above standard or contact Grundfos. Enclosure class IP55 as a minimum. Protected against sucking. This phenomenon may occur when the pressure inside the motor is lower the atmospheric pressure. In such cases, moisture is sucked from the atmospheric side into the motor through bearing housings, etc. From 1.1 to 75 kW, all VIK-approved motors are efficiency class 1 . EFF1 is the highest efficiency class defined by CEMEP. For further information about the VIK-standard, see www.vik.de or contact Grundfos.

cURus-, UR- and CSA-approved motors


We offer mains-operated motors with these approvals:
Approval cURus UR CSA Motor power - P2 [kW] 0.37 - 7.5 11 - 75 11 - 75

Other motor approvals


We offer a wide range of motor approvals: CCC C-tick GOST B TSU METI/JQA CB TSE SASO, etc.

18

Motor
ATEX-approved pumps
TM01 6193 4202
2)

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

For group II, category 2 G (zone 1), the pump must be protected against dry running. Use one of the following methods: An ATEX-approved dry-running protection. Always use this protection on pumps with MAGdrive or pumps with a single mechanical shaft seal. Pumps with double-seal system (back-to-back or tandem). The system for pressurising or flushing the double-seal system must be ATEX-approved.

ATEX-approved pumps are recommended for use in potentially explosive atmospheres. Explosive atmospheres consists of air and combustible material, such as gases, vapours, mists or dusts in which the explosion spreads after ignition. We offer explosion-proof or dust-ignition-proof motors in accordance with the EC directive 94/9/EC, the socalled ATEX directive. The ATEX-approved pumps can be used in areas (zones) classified according to the directive 1999/92/ EC. In case of doubt, consult the above-mentioned directives or contact Grundfos. ATEX-approved pumps will be supplied with serial number, special installation and operating instructions and a nameplate showing the ATEX classification. A pump report is available on request. Scope of ATEX categories
Group I Category M2 Underground installations in mines Pumps made of materials that do not liable to be endangered by explosive create sparks and thus do not congasses or combustible dust. stitute any danger of explosion. CR pumps available Motors available
1)

We offer the following ATEX-proof motors:


Motor [kW] Version (2G EExe II T3) (2G EExd IIB T4) (2D T125) (3D T125)

0.37 - 1.3 1.85 - 4.6 5.5 - 7.5 10 - 15 20 - 28 0.37 - 1.5 2.2 - 4 5.5 - 7.5 11 - 45 0.37 - 45 0.37 - 45

Motor

All explosion-proof motors have angular contact bearings and PTC- sensors. For further information about PTC-sensors, see page 22.

Special voltage
We offer pumps with the following voltages:
Frequency Mains-operated motor 3 x 220-240 /380-415 YV 50 Hz 3 x 200-220/346-380 V 3 x 380-415 V 3 x 380-415 /660-690 YV
Category 2

Voltage

CR, CRI, CRN None


1)

Air-driven or hydraulically driven motors are not available from Grundfos.

Group II Installation areas liable to be endangered by explosive atmospheres. 1999/92/EC


1)

3 x 200-230/346-400 V 3 x 208-230/460 V 3 x 220-255 /380-440 YV 3 x 220-277 /380-480 YV 60 Hz 3 x 220-277 /380-480 YV 3 x 380-440 V 3 x 380-480 V 3 x 380-480 /660-690 YV 3 x 575 YV Motor with integrated frequency converter 1 x 200-240 V 50/60 Hz 3 x 200-240 V 3 x 380-480 V

Pumps intended for use in areas in which explosive atmospheres are likely to occur. G (gas) Zone 1
2)

D (dust) Zone 21 CR, CRI, CRN, CRT 2D 125 C

CR pumps available CR, CRI, CRN, CRT Motors available 2G EEx e II T3 2G EEx d II B T4 Category 3 Installation areas liable to be endangered by explosive atmospheres. 1999/92/EC
1)

Pumps intended for use in areas in which explosive atmosphere only rarely occur. G (gas) Zone 2 2G EEx e II T3 2G EEx d II B T4 D (dust) Zone 22 CR, CRI, CRN, CRT 3D 125 C

Note: Other voltages are available on request.

CR pumps available CR, CRI, CRN, CRT Motors available


1)

Important: The link between groups, categories and zones is explained in the 1999/92/EC directive. Please note that this is a minimum directive. Some EEC countries may therefore have stricter local rules. The user or installer is always responsible for checking that the group and category of the pump correspond to the zone classification of the installation site.

19

Motor
Motor with multi-plug connection
Dimensions

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

129

167

Motor

Gr7550

Fig. 12 Dimensions 0.37 - 1.1 kW

Fig. 10 Mains-operated motor with Harting 10-pin multiplug

The purpose of a multi-plug connection is to make the electrical installation and service of the pump easier. The multi-plug functions as a plug-and-pump device. The drawings below show the position of the multi-plug on the mains-operated motor.
TM01 8713 0700 - TM02 8518 0304

Fig. 13 Dimensions 1.5 - 7.5 kW

Plug connections

6
W2 U2 V2

10

U1

V1

W1

Fig. 14 Plug connection from motor

Fig. 11 Motor with multi-plug connection

L1 1

L2 2

L3 3 4 5
TM01 8703 0700 TM01 8704 0700

The multi-plug connection is available for the following motor sizes:


Motor power P2 [kW] 0.37 - 7.5 0.37 - 7.5 Voltage [V], starting method 3 x 220-240 /380-415 YV 3 x 380-415 V

10

Logo for multi-plug

Fig. 15 Plug connection for star connection

L1 1
TM02 0470 0700

L2 2

L3 3 4 5

10

Fig. 16 Plug connection for delta connection

Note: Fishplates for connections are located in the plug.

20

TM01 8702 0700

TM01 8714 0700

Mains-operated motors fitted with a Harting 10-pin multi-plug connection, HAN 10 ES, enable easy connection to the mains. Note: For Grundfos motors with integrated frequency converter up to 7.5 kW, we offer the solutions shown on page 21.

192 230

TM01 8716 0700

Motor
Plug-and-pump solutions for CRE pumps To facilitate electrical installation and service of our three-phase CRE pumps up to 7.5 kW, all motor terminal boxes are equipped with a detachable cable inlet bar. When the cable inlet bar is removed, it is possible to disconnect all electrical connections. Fig. 17 shows the location of the detachable cable inlet bar on the motor terminal box as well as plugs for mains connection, sensor and communication.

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

result of shock cooling caused by direct sunlight followed by rain. It is advisable always to use motors with anti-condensation heater in areas with ambient temperatures below 0 C. Note: Rapid condensation is not to be confused with the phenomenon which occurs when the pressure inside the motor is lower than the atmospheric pressure. In such cases, moisture is sucked from the atmosphere into the motor through bearings, housings etc.

Motor

In applications with constant high humidity levels above 85 %, the drain holes in the drive-end flange must be open. This changes the enclosure class to IP44. If IP55 protection is required due to operation in dusty environments, it is advisable to install a motor with anticondensation heater. The figure below shows a typical circuit of a threephase motor with anti-condensation heater.

TM03 1964 3405 - TM03 1962 3405

Fig. 19 Three-phase motor with anti-condensation heater

Key
Symbol K M Designation Contactor Motor

Fig. 17 Location of the detachable cable inlet bar on the motor terminal box as well as plugs for mains connection, sensor and communication

Motor with anti-condensation heater

Note: Connect the anti-condensation heater to the supply voltage so that it is on when the motor is switched off. Motors from 0.37 to 75 kW are available with anti-condensation heater.

TM03 2440 4305

The following motor sizes available with anti-condensation heater:


Motor size, 50/60 Hz [kW] 2-pole 0.37 - 1.1 1.5 - 3.0 4.0 - 5.5 7.5 - 22 30-37 45 - 55 75
1)

Fig. 18 Mains-operated motor with anti-condensation heater

Power of heating unit [W] 1 x 24 V 38 2 x 38 55 92 109 1 x 115 V 1 x 190-250 V 23 31 38 2 x 38 55 92 109

4-pole 0.25 - 0.75 1.1 - 3.0 4.0 5.5 - 15 1) 18.5 1)

In applications where condensation in the motor may occur, we recommend to install a motor with an anticondensation heater on the stator coil ends. The heater keeps the motor temperature higher than the ambient temperature and prevents condensation. High humidity may cause condensation in the motor. Slow condensation occurs as a result of a decreasing ambient temperature; rapid condensation occurs as a

15 and 18.5 kW 4-pole are oversize motors in the CR pump range.

TM03 4058 1406

21

Motor
Motors with PTC sensors
Key
Symbol S1 K1 +T
TM02 7038 2403

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Designation On/off switch Contactor PTC sensor (thermistor) in motor Motor Tripping unit with automatic reset Amplifier Output relay LED Ready LED Tripped Connection for control voltage Connection for PTC sensor loop

M 3UN2 100-0 C N K H1 H2 A1, A2 T1, T2

Motor

Fig. 20 PTC sensor incorporated in winding

Built-in PTC sensors (thermistors) protect the motor against rapid as well as slow overheating. We offer motors with temperature-controlled PTC sensors in the motor windings. Three-phase mains-operated motors from 3 kW and up have PTC sensors as standard. Note: Temperature-controlled PTC sensors must be connected to an external tripping or LiqTec unit connected to the control circuit. For further information about LiqTec, see page 50. Protection according to IEC 60034-11: TP 111 (slow overheating only) TP 211 (slow and rapid overheating). PTC sensors comply with DIN 44 082. Maximum voltage at the terminals, Umax = 2.5 VDC. All tripping units available for DIN 44 082 PTC sensors meet this requirement. The figure below shows a typical circuit of a threephase motor with PTC sensors.
L1 L2 L3 N

Motors with thermal switches

Fig. 22 Thermal switch incorporated in winding

Built-in thermal switches protect the motor against rapid as well as slow overheating. We offer mains-operated motors with bimetallic thermal switches in the motor windings. Three-phase mains-operated motors from 0.37 to 11 kW are available with built-in thermal switches. Note: Thermal switches must be connected to an external control circuit to protect the motor against slow overheating. The thermal switches require no tripping unit. Protection according to IEC 60034-11: TP 211 (slow and rapid overheating). As protection against seizure, the motor must be connected to a motor-protective circuit breaker. Thermal switches tolerate the following maximum loads:
Umax IN Imax 250 VAC 1.5 A 5.0 A (locked-rotor and breaking current)

3UN2 100-0 C A1 H1 H2 N T1 T2 A2 K
96 98 95

S1

K1

K1

TM00 3965 1494

M 3

The figure below shows a typical circuit of a threephase motor with built-in bimetallic thermal switches.

Fig. 21 Three-phase motor with PTC sensors

22

TM02 7042 2403

Motor
Oversize motors

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

It is advisable to use an oversize motor if operating conditions fall outside the operating conditions described in these data booklets: CR, CRI, CRN, CRE, CRIE, CRNE CR, CRN high pressure CRT, CRTE. We especially recommend oversize motors in these cases: The pump is installed at an altitude above 3500 m (MG EFF1), 2875 m (Siemens EFF1), and 1000 m (MG EFF2). The viscosity or density of the pumped liquid is higher than that of water.
TM00 3964 1494

Motor

The ambient temperature exceeds +60 C (MG EFF1), +55 C (Siemens EFF1) or +40 C (EFF2). We offer the following oversize motors. Mains-operated motors
Oversize motors (three-phase) 2-pole 0.55 4-pole 0.37 0.55 0.75 1.1 1.5 2.2 3.0 4.0 5.5 7.5 11.0 15.0 18.5

Fig. 23 Three-phase motor with thermal switches

Key
Symbol S1 K1 t M MV Designation On/off switch Contactor Thermal switch in motor Motor Motor-protective circuit breaker

0.75 1.1 1.5 2.2 3.0 4.0 5.5 7.5 11.0 15.0 18.5 22.0 30.0 37.0 45.0 55.0 75.0

23

Motor
Motors with integrated frequency converter
Oversize motors (three-phase) 2-pole 0.55 0.75 1.1 1.5 2.2 3.0 4.0 5.5 7.5 11.0 15.0 18.5 22.0 4-pole 0.37 0.55 0.75 1.1 1.5 2.2 3.0 4.0 5.5

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Undersize motors
It is advisable to use an undersize motor if operating conditions fall much inside the standard conditions described in these data booklets: CR, CRI, CRN, CRE, CRIE, CRNE CR, CRN high pressure CRT, CRTE. We especially recommend undersize motors in these cases: The viscosity or density is lower than that of water. The duty point of the pump is constant, and the flow rate is significantly lower than the maximum recommended flow rate. We offer the following undersize motors. Mains-operated motors
Undersize motors (three-phase) 2-pole 0.37 0.55 0.75 1.1 1.5 2.2 3.0 4.0 5.5 7.5 11.0 15.0 18.5 22.0 30.0 37.0 45.0 55.0 4-pole 0.25 0.37 0.55 0.75 1.1 1.5 2.2 3.0 4.0 5.5 7.5

Motor

Motors with integrated frequency converter


Undersize motors (three-phase) 2-pole 0.37 0.55 0.75 1.1 1.5 2.2 3.0 4.0 5.5 7.5 11.0 15.0 18.5 4-pole 0.25 0.37 0.55 0.75 1.1 1.5 2.2 3.0 4.0

24

Motor
Motor sizes available for pumps
2-pole
Pump type CR 1s - CR 5 CR 10 - CR 20 CR 32 - CR 90 CR 120 - CR 150 Undersize motor [kW] 0.37 0.37 1.5 7.5 Oversize motor [kW] 7.5 18.5 45 75

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

4-pole

Motor

Pump type CR 1s - CR 5 CR 10 - CR 20 CR 32 - CR 90 CR 120 - CR 150

Undersize motor [kW] 0.25 0.25 1.5 1.5

Oversize motor [kW] 1.5 4.0 11 18.5

25

Motor
Alternative enclosure class (IP class)
The motor enclosure class complies with IEC 60034-5. The enclosure class states the degrees of protection of the motor against ingress of solid objects and water. As standard all motors comply with IP55. On request, we offer motors in accordance with IP54 and IP65.

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

4-pole motors

Motor

Fig. 25 4-pole motor

IP class IP54

Description The motor is protected against the ingress of dust, i.e. harmful layers of dust. The motor is protected against water splashing from any direction. The motor is protected against the ingress of dust, i.e. harmful layers of dust. The motor is protected against water being projected by a nozzle from any direction. The motor is protected against the ingress of dust. The motor is protected against heavy seas or highpressure water jets from any direction. The motor is completely dust-proof. The motor is protected against water being projected by a nozzle from any direction.

We offer all CR pumps with 4-pole motors. 4-pole motors are often preferred in these cases: A low sound pressure level is required. Inlet conditions are poor. Beating of the liquid is not allowed. Performance curves and technical data of 4-pole CR pumps, see page 87 to 110 and 126 to 139. Electrical data of 4-pole CR pumps, see pages 155 and 156.

IP55

IP56

IP65

Alternative terminal box positions


As standard, the terminal box is in position 6 oclock. The possible terminal box positions are shown below.

Efficiency class 2 motors


As standard, all three-phase pumps are fitted with EFF1 motors. We also offer motors from 0.37 to 45 kW according to the European efficiency class, EFF2. The motors are classified under the EU/CEMEP motor efficiency labelling scheme.

TM03 3658 0606

Other motor brands


We also offer pumps with a motor of any make which can fulfil the requirements as to flange dimensions bearing specifications pump shaft. Alternatively, Grundfos pumps can be supplied without a motor.

Position 6 (standard)

Position 9

Position 12

Position 3

Fig. 24 Possible terminal box positions

26

TM03 1711 2805

Shaft seals
Shaft seal arrangements
Depending on the application, CR pumps are available with these shaft seals: single seal arrangement double seal arrangement magnetic drive. As standard, CR(E), CRI(E), CRN(E) pumps are fitted with a cartridge shaft seal mounted in a single seal arrangement: HQQE or HQQV (0.25 - 45 kW) HBQE or HBQV (55 - 75 kW). CRT(E) are fitted with one AUUE or AUUV O-ring seal as standard. In applications where the pumped liquid may harm the environment, double seal arrangements or magneticdrive pumps are selected. To ensure reliability, these conditions must be considered when selecting a shaft seal: operating pressure type of pumped liquid liquid temperature.
CRT(E) Pump type

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Shaft seal variants


Liquids or applications exceeding the range of normal operating conditions require special-purpose shaft seal solutions. In order to meet any specific requirements, we offer variants of seal face material and secondary seal material (rubber parts). The following tables apply to clean water and water containing glycol. Shaft seal and seal face variants
Shaft seal, seal face variant HQQx CR(E), CRI(E), CRN(E) HBQx HQBx HUUx HUBx AQQx DQQx *) Temperature [C] Min. 40 0 0 40 0 40 40 Max. +120 +120 +120 +90 +120 +90 +90 Pressure rating [bar] 30 30 30

Shaft seal

30 30 25 25

*) Only for CR, CRN 120 and 150, 55-75 kW.

Overview of shaft seals


The below table shows the shaft seals available.
Shaft seal As standard CR(E), CRI(E) and CRN(E) HQQE HQQV HQQE *) HQQV *) HUBE HUBV HBQE *) HBQV *) HUUE HUUV HUUK HUUF HUBF HUBK HQQK HQQF HQBE HQBV HQBK KUHE KUHV KUUV KUUE CRT(E) AUUE AUUV AUUK AQQE AQQV AQQK DQQE DQQV DQQK *) Only for CR, CRN 120 and 150, 55-75 kW. On request

For explanation of codes, shaft seal types and materials, see the type key on page 10, or see the data booklet "Shaft seals" which is available in WebCAPS.

Codes for shaft seals, see page 10.

27

Shaft seals
Shaft seals with EPDM O-ring material (HxxE) Shaft seals with EPDM O-ring material are recommended for water and aqueous solutions. EPDM rubber is non-resistant to mineral oils. Temperature range for rubber material: heat resistant up to +150 C resistant to water up to +140 C. Shaft seals with FKM O-ring material (HxxV) Shaft seals with FKM O-ring material are recommended for a wide range of temperatures and pumped liquids, such as acids, saline solutions, mineral oil, vegetable oil and most solvents. Temperature range for rubber material: heat resistant up to +240 C (oil only) resistant to water up to +90 C.

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Double seal arrangements


We offer two double seal arrangements: back-to-back (OQQx) tandem (PQQx).

Back-to-back seal arrangement


Back-to-back seal arrangements consist of two Grundfos cartridge shaft seals, type O, fitted back-toback in a separate seal chamber. This type of seal arrangement is recommended for handling these types of liquid: toxic, aggressive or flammable liquids abrasive or sticky liquids which would either wear out, damage or block a mechanical shaft seal. The back-to-back double seal protects the surrounding environment and the people working in the vicinity of the pump. It is specially designed for operating pressures up to 25 bar and +120 C with the aim of minimising the risk of leakage from the pump to the environment.

Shaft seal

Shaft seals with FFKM O-ring material (HxxK) Shaft seals with FFKM O-ring material are recommended for a wide range of pumped liquids, such as nitric acid, solvents, varnishes, paints and dyes. Temperature range for rubber material: resistant to water up to +150 C. Shaft seals with FXM O-ring material (HxxF) Shaft seals with FKM O-ring material are recommended for high temperatures as well as for acid liquids and gasses within oil and gas extraction.

10 C to +275 C. For short periods up to +300 C. Plug and sleeve O-rings made of FXM are available for the full range. For further information about O-ring materials, see the following data booklets available in WebCAPS.
Data booklet CR, CRI, CRN, CRE, CRIE, CRNE, 50 Hz CR, CRI, CRN, CRE, CRIE, CRNE, 60 Hz CRT, CRTE Shaft seals Publication number V7023751 96488672 V7149894 96519875

Fig. 26 CR 1s to 5 with back-to-back seal arrangement

Fig. 27 CR 10 to 20 with back-to-back seal arrangement

28

TM04 4405 1609

TM04 4404 1609

Temperature range for rubber material:

Shaft seals

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

TM04 4267 1609

Pressurising In back-to-back seal arrangements, the pressure in the seal chamber must be higher than the pump pressure to prevent the pumped liquid from leaking through the shaft seal to the environment. Note: The barrier fluid will seep through the lower (primary) shaft seal and be mixed with the pumped liquid. The right barrier fluid must therefore be used. The pressure in the seal chamber can be generated in three ways: by an existing pressure source by a dosing pump by a pressure intensifier. For further information about Grundfos back-to-back seal arrangements, see the data booklet "Shaft seals" which is available in WebCAPS.

Fig. 28 CR 32 to 90 with back-to-back seal arrangement

Shaft seal

Fig. 29 CR 120 and 150 with back-to-back seal arrangement

Key to figures 26, 27, 28 and 29


Pos. 1 2 3 Designation Seal chamber Shaft seals Pump
TM03 3810 1106

The back-to-back seal arrangement is available for the following CR pumps:


Pump type CR(E) CRI(E) CRN(E) Available. Pos. 1 2 Additional height of seal chamber [mm] 108 90 210 240 166 184 111 3 4 5 6 Designation Pump Pressure tank Dosing pump Pressure switch Manometer Reservoir with barrier fluid 1s 1 3 5 10 15 20 32 45 64 90 120 150

TM04 4406 1609

CR pump with dosing pump The example below shows a CR pump with a back-toback seal arrangement. The barrier fluid is supplied and pressurised by a dosing pump.

Fig. 30 CR pump with dosing pump

Key

Dimensions
Pump type CRI, CRN 1s, 1, 3, 5 CRI, CRN 10, 15, 20 CR, CRN 32 CR, CRN 45 CR, CRN 64 CR, CRN 90 CR, CRN 120, 150

The setpoint of the barrier fluid pressure is set by means of the pressure switch (pos. 4). When the pressure drops below the setpoint, the dosing pump will start and thus maintain a higher pressure in the seal chamber (max. pressure 16 bar). Barrier fluid is supplied from a reservoir (pos. 6).

29

Shaft seals
One dosing pump can supply several pumps with backto-back seal arrangements. Connections are all RG 1/2". Note: Connecting pipes/hoses are not included. Dimensions of backplate with components

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

CR pump with pressure intensifier

Fig. 32 CR pump with pressure intensifier 8

Shaft seal

6 5
TM03 4660 2406

Fig. 31 Dimensional sketch 7

3 2 1

Fig. 33 Components of pressure intensifier


Pos. 1 2 3 4 5 6 7 8 9 Designation Pressure intensifier Piston Diaphragm Non-return valve Relief valve Vent screw, Rp 1/8 Spring for piston Pressure gauge (barrier fluid) Pressure gauge (pumped liquid)

30

TM03 8299 1007

GR5954

Shaft seals
The seal chamber is primed with barrier fluid via a nonreturn valve (pos. 4) until the pressure gauge (pos. 8) reaches 1.5 to 2 bar. The spring (pos. 7) is now preloaded with the barrier fluid pressure. The pump is primed and vented. When the pump is started, the pump pressure + the pressure from the preloaded spring will result in a pressure 1.5 to 2 bar higher in the seal chamber. Note: One pressure intensifier can only supply one pump. The pressure intensifier is fitted on the pump from factory. Maximum operating pressure: 25 bar. Dimensions

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Shaft seal

Fig. 34 Dimensional sketch


Pump type CR, CRI, CRN 1, 3, 5 CR, CRI, CRN 10, 15, 20 CR, CRN 32 CR, CRN 45 CR, CRN 64 CR, CRN 90 CR, CRN 120, 150 a [mm] 297 330 342 349 349 355 355 b [mm] 108 90 210 240 166 184 111 c [mm] 128 140 155 164 164 170 170

Note: The dimension "b" is the additional height as compared to the standard pump.

TM01 4459 0399

31

Shaft seals
Tandem seal arrangement
Tandem seal arrangements consist of two Grundfos cartridge shaft seals, type P, mounted tandem in a separate seal chamber. Tandem seals are recommended for crystallizing, hardening or sticky liquids. CR 1s, 1, 3, 5, 10, 15 and 20 Key
Pos. 1 2 3 Designation Seal chamber Shaft seals Pump

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

The tandem type of seal is available for these CR pumps:


Pump type CR(E) CRI(E) CRN(E) Available. 1s 1 3 5 10 15 20 32 45 64 90 120 150

TM03 3657 0606

Dimensions
Pump type CRI, CRN 1s, 1, 3, 5 CRI, CRN 10, 15, 20 CR, CRN 32, 45, 64, 90 CR, CRN 120, 150 Additional height of seal chamber [mm] 108 90 0 111

Shaft seal

Fig. 35 CR 1s to 20 with tandem seal arrangement

CR 32, 45, 64 and 90

Flushing-liquid systems CR pumps with tandem seal arrangement must be equipped with a flushing-liquid system. Note: The pumped liquid will seep through the lower (primary) shaft seal and be mixed with the flushing liquid. Maximum liquid temperature: +120 C. The flushing-liquid flow rate should also be matched to the application (recommended flow rate 25-200 l/h). The pressure of the flushing liquid must always be lower than the pressure of the pumped liquid. Note: The flushing-liquid supply must never be connected directly to the public water supply system. Local regulations must be observed. For further information about Grundfos tandem seal arrangements, see the data booklet "Shaft seals" which is available in WebCAPS. The following figures show examples of flushing systems for tandem seal arrangements.
TM04 4164 1609

Fig. 36 CR 32 to 90 with tandem seal arrangement

CR 120 and 150

Fig. 37 CR 120 and 150 with tandem seal arrangement

32

TM03 9158 3507

Shaft seals

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Minimum 1 metre
TM03 3813 1106

TM04 3217 2408

Fig. 38 Tandem seal arrangement with circulating flushing liquid

Fig. 40 Tandem seal arrangement with flushing liquid connected to a drain

In fig. 38, the flushing liquid circulates between an elevated tank and the pump by natural circulation. Heated flushing liquid rises from the seal chamber to the tank where it cools down. The cooled-down flushing liquid returns to the seal chamber. At high temperatures, the circulation of flushed liquid through the seal chamber cools the seal faces of the shaft seal and reduces noise.

In fig. 40, the flushing liquid enters the seal chamber via a pipe from an elevated tank. In case of leakage, the pumped liquid is washed away to the drain by the flushing liquid.

Shaft seal

Fig. 39 Tandem seal arrangement with flushing-liquid supply

In fig. 39, the flushing liquid enters the seal chamber via a pipe from an elevated tank. No heat is dissipated from the system.

TM03 3809 1106

33

Shaft seals
CR with air-cooled top
CR pumps with an air-cooled top are used where the pumping of hot liquids is crucial for a successful production. A CR pump with an air-cooled top is a pump with a special air-cooled shaft seal chamber generating the same insulation effect as that of a vacuum flask. No external cooling is necessary; the ambient temperature is sufficient. CR 1s, 1, 3 and 5

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Fig. 42 CR 1s, 1, 3 and 5 with air-cooled top

CR 10, 15 and 20

Shaft seal

Fig. 41 CR pump with an air-cooled top

CR 1s to 90:

+240 C at max. PN 16.

Fig. 43 CR 10, 15 and 20 with air-cooled top

CR 120 and 150: +180 C at max. PN 16. The following rubber part variants are available for our air-cooled top solutions:
Liquid temperature [C] Water-based liquids 120-150 120-180 Thermal oils 120-240 FKM EPDM FXM/EPDM Rubber part material

CR 32, 45, 64 and 90

Temperatures above +120 C normally result in a substantial reduction of seal life due to poor lubrication of the seal faces. As the temperature in the seal chamber does not exceed +120 C during operation, a standard Grundfos shaft seal can be used. An automatic air vent is required for venting the pump seal chamber. Note: For safety reasons it is advisable to fit a pipe in order to lead away steam from the air vent to a drain. Local regulations must be observed.
Fig. 44 CR 32, 45, 64 and 90 with air-cooled top

34

TM03 4060 1406

TM03 9160 3507

As standard, CR pumps with air-cooled top have a mechanical silicon carbide/silicon carbide/EPDM cartridge shaft seal, type HQQE. The pumps are able to handle liquid temperatures up to +180 C at max. PN 25. Note: If the pumped liquid is oil, the pumps can handle following liquid temperatures:

GR5228

TM03 9159 3507

Shaft seals
CR 120 and 150

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Air vent positions on CR pumps with air-cooled top As standard, the air vent of vertical CR pumps with aircooled top is in line with the discharge port (12 oclock position). The air vent is mounted vertically (12 oclock position) on horizontal pumps. The possible air vent positions are shown below. Vertical CR pumps with air-cooled top
TM04 4165 0909

Fig. 45 CR 120 and 150 with air-cooled top

3 oclock

12 oclock

Key
Pos. Designation Air chamber Liquid Air vent Shaft seal Cooling channel 6 oclock
TM03 3659 0606

Shaft seal

1 2 3 4 5

Fig. 46 Air vent positions on vertical CR pumps

Pump range The air-cooled top is available for these pump types:
Pump type CR(E) CRI(E) CRN(E) Available. Note: CRT(E) pumps are not available with air-cooled top. CR pumps with air-cooled top 1s 1 3 5 10 15 20 32 45 64 90 120 150

Bearing flanges for CR pumps with air-cooled top When pumping water up to +180 C, the pump requires a net positive inlet pressure according to the vapour pressure of water. A bearing flange is incorporated in the following pump types.
50 Hz CRI, CRN 10-1 - 10-6 CRI, CRN 15-1 - 15-3 CRI, CRN 20-1 - 20-3 CR, CRN 32-2-2 - 32-4 CR, CRN 45-1-1 - 45-2 CR, CRN 64-1-1 - 64-2-2 CR, CRN 90-1-1 - 90-1 60 Hz CRI, CRN 10-1 - 10-5 CRI, CRN 15-1 - 15-2 CRI, CRN 20-1 CR, CRN 32-1 - 32-2 CR, CRN 45-1-1 - 45-1 CR, CRN 64-1-1

35

Shaft seals
Dimensions

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Magnetic-drive pump (MAGdrive)


Grundfos CRN MAGdrive pumps operate according to a patented, magnetic-drive system that eliminates the need for shaft seals. The power from the motor is transmitted to the pump by magnetic force and not by a conventional coupling. Combined with a hermetically sealed liquid end, the pump is totally leak-free. As all axial forces are absorbed in the MAGdrive system, the pump incorporates a standard ICE or NEMA motor with keyway and deep-groove ball bearing.

Fig. 47 Air-cooled top


Pump type CRI, CRN 1s, 1, 3, 5 (< 3 kW) CRI, CRN 1s, 1, 3, 5 (3 - 7.5 kW) CRI, CRN 10, 15, 20 (< 4 kW) CRI, CRN 10, 15, 20 (4 - 7.5 kW) CRI, CRN 10, 15, 20 (11 - 18.5 kW) CR, CRN 32 CR, CRN 45, 64 CR, CRN 90 CR, CRN 120, 150 (11 - 45 kW) CR, CRN 120, 150 (55 - 75 kW) x [mm] 120 172 140 200 230 176 186 190 190 243
GrA4445

Shaft seal

TM03 4082 1609

Fig. 49 CRN MAGdrive pumps

Additional pump height


Pump type CRI, CRN 1, 3, 5 CRI, CRN 10, 15, 20 CR, CRN 32 CR, CRN 45 CR, CRN 64 CR, CRN 90 CR, CRN 120, 150 Additional pump height [mm] 108 90 210 240 166 184 111

The MAGdrive solution is available for these pumps:


Pump type CRN(E) Available. * Available up to 22 kW. CRN pumps with magnetic drive 1s 1 3 5 10 15 20 32 * 45 * 64 * 90 *

As minimum, a soft starter is required for these motors: 2-pole motors: 18.5 and 22 kW. 4-pole motors: 1.1 kW and up. Features and benefits CRN MAGdrive offers the following special features and benefits:
TM03 4084 1609

Horizontal CR pumps with air-cooled top

a hermetically sealed drive system for 100 % leakfree pump operation special choice of materials and design for low energy loss simple pump design for ease of service unique pump design for efficient cooling of magnet by means of the pumped liquid ATEX version available.

Fig. 48 Air vent positions on horizontal CR pumps with air-cooled top

Key to fig. 48
Pump type CRI, CRN 1s, 1, 3, 5 CRI, CRN 10, 15, 20 CR, CRN 32 CR, CRN 45, 64 CR, CRN 90, 120, 150 x [mm] 308 324 391 398 404

Note: 75 kW motors are higher than distance x.

36

Shaft seals
Applications The CRN MAGdrive pump is suitable for wide selection of industrial applications such as: Aggressive or corrosive liquids Concentrated sulphuric acid, nitric acid, phosphoric acid, etc. Toxic liquids Trichloroethylene, chloroform, phenol, etc. Flammable liquids Petrol, jet fuels, LPG, alcohols, etc. Hardening/curing liquids Paint, glue, resins, etc. Crystallising liquids Glycol additives, naphthalene, sugar products, salts, etc. Refrigerants Ammonia, synthetic chemicals (CFC, HCFC, HCF), etc. Design

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Construction The magnetic field is generated by two magnets; the outer magnet is driven by the motor, and the inner magnet is connected to the pump. The two shafts are not connected.

Shaft seal

TM03 9149 3407

Fig. 51 Sectional drawing of MAGdrive system


Pos. Designation 1 2 3 4 5 6 Outer drive Outer magnets Can Inner drive Inner magnets Rotating thrust bearing Material 1.4301 NdFeB (neodymium) 1.4539 1.4401 NdFeB (neodymium) SiC Q1G (silicon carbide, carbon-filled) SiC (silicon carbide) Graflon (carbon-graphite-filled PTFE) CRN 1s-5 CRN 10-20 CRN 32-90 1.4408 EPDM, FKM, FXM, FFKM : 1.4401 : 1.4460 : 1.4462

Fig. 50 MAGdrive system


Pos. 1 2 3 Designation Motor stool MAGdrive Pump head Stainless steel (EN 1.4408) Materials Cast iron. Stainless steel on request

7 8 9 10 11 12

Stationary thrust bearing SiC Q1G (silicon carbide, carbon-filled) Radial bearing Upthrust bearing Drive/pump shaft Pump head O-ring

The configuration of the CRN MAGdrive pump is almost identical to that of the standard CRN pump. The following rubber parts solutions are available: EPDM FXM (Fluoraz) FFKM (Kalrez) FKM (Viton). Connections available for CRN MAGdrive pumps:
Connection type DIN, ANSI, JIS flange PJE FlexiClamp, union, oval flange, TriClamp Available. CRN 1s, 1, 3, 5, 10, 15, 20 32, 45, 64, 90

TM03 9141 3407

37

Shaft seals
Operating conditions Maximum pressure: 25 bar. Temperature range: 40 C to +120 C. Viscosity range: 0.3 to 300 mPas. Technical data Motor range: 0.37 kW to 22 kW. Dimensions The height of the MAGdrive system typically makes the pump a little higher than a standard CRN pump. Some pump sizes have a larger motor than the standard range. For dimensions and weights for CRN MAGdrive pumps, see page 140 to 153. Note: When ordering a Grundfos MAGdrive, please state the data: liquid temperature [C] liquid viscosity [mPas] liquid density [kg/m3] frequency [Hz]. Above information is required for the selection of the correct MAGdrive/motor combination.

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Shaft seal
38

Pump
PN 25 and PN 40 pumps
We offer custom-built pump solutions for the following inlet pressures: CR 1 to CR 20: up to 25 bar. CR 32 to CR 150: up to 40 bar. Note: In applications with high inlet pressures, a bearing flange must be fitted. For further information, see the CR, CRN high-pressure data booklet (publication number V7174003).

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

We offer these pump types with tappings:


Pump type CR(E) CRI(E) CRN(E) Available. 1s 1 3 5 10 15 20 32 45 64 90 120 150

Note: As standard, CR(E) and CRN(E) 32, 45, 64 and 90 have tappings for measurement of pump inlet pressure.

Measurement of inlet pressure


As CR 1s to CR 20 pumps are not equipped with a connection for the measurement of pump inlet pressure, we offer custom-built pumps with a tapping for a pressure gauge or pressure sensor.

Pumping of liquids down to 40 C


We offer custom-built pumps for the pumping of liquids down to 40 C. The pumps have an oversize neck ring ensuring that impellers do not seize up as a result of thermal expansion. We offer the above solution for these pump types:
Pump type 1s 1 3 5 10 15 20 32 45 64 90 120 150

TM03 4726 2506

CR(E) CRI(E) CRN(E) Available. Standard CRN 32, 45, 64 and 90 pumps with shaft seal type HQQE are suitable for liquid temperatures down to 40 C.

Fig. 52 CR pump with pressure gauge

Pump

Fig. 53 Insert for measurement of inlet pressure

The material of the insert is stainless steel (AISI 316).


Designation Rubber material EPDM FKM FFKM FXM CRI, CRN 1s, 1, 3, 5 EPDM Insert for measurement of inlet pressure FKM FFKM FXM CR 10, 15, 20 EPDM FKM EPDM FKM RG 1/4 62 96584117 96584119 96584121 96584122 RG 1/4 51.5 96562253 96562254 96562255 96562256 RG 1/4 57 Connection L [mm] Product number 96488082 96562250 96562251 96562252

CR 1s, 1, 3, 5

CRI, CRN 10, 15, 20 RG 1/4 53

TM03 4091 1606

39

Pump
Surface treatment
Cleaned and dried pumps Cleaned and dried pumps are recommended for use in applications involving strict demands to cleanliness and surface quality, such as low content of silicone. To meet these strict demands, we offer these cleaned dried pump types:
Pump type CR(E) CRI(E) CRN(E) Available. 1s 1 3 5 10 15 20 32 45 64 90 120 150

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

We offer these electro-polished pumps:


Pump type CR(E) CRI(E) CRN(E) Available. 1s 1 3 5 10 15 20 32 45 64 90 120 150

Carbon-free pumps Certain processes, such as pumping of pure water in electronics industries, require pumps that do not contain carbon. To meet such requirements, we offer these 100 % carbon-free pump types:
Pump type CR(E) CRI(E) CRN(E) Available. As standard, pumps with HQQx shaft seal are carbon-free. 1s 1 3 5 10 15 20 32 45 64 90 120 150

Prior to assembly, all pump parts are cleaned in 60 to 70 C water with a cleaning agent. All pump parts are then thoroughly rinsed in de-ionised water and airdried. The pump is assembled without any use of silicone lubricants. Finally, the pump is packed in siliconefree plastic. Note: Silicone-free shaft seals are available as option. Cleaned and dried pumps are not performance tested. Electro-polished pumps Electro-polished pumps are often used in the pharmaceutical industry and in the food and beverage industry where materials and surface quality must meet strict requirements to hygiene or corrosion resistance. Electro-polishing removes burrs as well as metallic and non-metallic inclusions, providing a smooth, clean and corrosion-resistant stainless steel surface. First all components are pickled in a mixture of nitric and hydrofluoric acid. Subsequently, the components are electro-polished in a mixture of sulphuric and phosphoric acid. Finally, the components are passivated in nitric acid. All cast parts of CRN 1s, 1, 3, 5, 10, 15 and 20 are polished mechanically before being electro-polished. Note: The pump incorporates a standard shaft seal which has not been polished. To meet the strict hygienic requirements to material and surface quality, we offer electro-polished stainless steel pumps with the following surface quality:
Pump type CRN 1s, 1, 3, 5, 10, 15, 20 CRN 32, 45, 64, 90 *) Cast stainless steel Stainless steel Surface quality parts (not cast) Ra 0.8 m Ra 15 m Ra 0.8 m

Pump

Available. *) Pump head, pump base and pump base plate are not electropolished.

40

Pump
Alternative colouring We offer custom-built pumps in any NCS- or RAL specified colour to suit your requirements! The used paint is water-based. Painted parts correspond to corrosion class III. All pump types and sizes are available with alternative colouring.

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

The CR low-NPSH pump is a pump with a special firststage design that reduces the pumps NPSH value and prevents erosion and destruction of the pump, pipework and valves. The improved inlet design may expose the low-NPSH pump to a higher level of stress as compared to conventional pumps, without affecting the stability of operation. The CR low-NPSH pump reduces the excess pressure itself and does not require any additional tank to provide supplementary pressure. In boiler feed applications where many large tanks are gathered, a compact system is an advantage.

CRN all-stainless steel pumps


We offer custom-built stainless steel CRN pumps for maritime applications, very humid environments, etc.: pump with stainless steel motor stool pump with stainless steel base pump with stainless steel flanges. We offer the above solutions for these pump types:
Pump type CR(E) CRI(E) CRN(E) Available. *) Only available with stainless steel base and flanges. *) *) 1s 1 3 5 10 15 20 32 45 64 90 120 150

Fig. 54 Sectional drawing of CR low NPSH pump

Note: The dimensions of custom-built stainless steel CRN pumps do not differ from those of standard CRN pumps.

Key
Pos. 1 2 Designation Special inlet part Special inlet impeller

TM03 4063 1406

Pump

CR low NPSH
Cavitation is often a problem in applications where pumps have to deal with the combination of high liquid temperatures, poor inlet pressure and/or high flow rate. For further information about NPSH and the calculation of NPSH value, see these data booklets: CR, CRI, CRN, CRE, CRIE, CRNE CR, CRN high pressure CRT, CRTE. Low-NPSH pumps are designed to eliminate the risk of cavitation and ensure a stable and reliable operation.

Pump range These pump types are available as low-NPSH pumps:


Pump types CR(E) CRI(E) CRN(E) Available. Maximum pressure Maximum liquid temperature
1)

CR low-NPSH pumps 1s 1 3 5 10 15 20 32 45 64 90 120 150

25 bar +120 C 1)

With air-cooled top, the maximum liquid temperature is +180 C.

For further information about CR low-NPSH pumps, see pages 71 to 86. For information about sectional drawings, dimensions and weights, see pages 113 to 125.

41

Pump
Horizontal pumps

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

CR(E), CRI(E), CRN(E) 5 (5.5 - 7.5 kW) CR(E), CRI(E), CRN(E) 10, 15, 20 ( 5.5 kW)
B1

GR5379

Fig. 55 Horizontal CR pump

Horizontal pumps are used in applications for safety and/or space-saving reasons. In earthquake areas, horizontal pumps are more reliable than vertical pumps. In case of earthquake, the design and mounting of the pump will dampen the oscillations of the pump. In installations with limited access or space, we recommend horizontal pumps to improve installation and service. Pump range These Grundfos pumps are available for horizontal mounting:
Pump types CR(E) CRI(E) CRN(E) Available. *) Available up to 55 kW. Horizontal CR pumps 1s 1 3 5 10 15 20 32 45 64 90 120 *
)

X C

AB

AAA AA A

CR(E), CRN(E) 32, 45, 64, 90, 120, 150

150 *) *)

Pump

*)

CRT(E) 2, 4, 8 and 16 pumps are also available for horizontal mounting. The pumps are supplied with separate mounting plates for support of motor and pump. Dimensional drawings CR(E), CRI(E), CRN(E) 1s, 1, 3, 5 ( 4 kW) CR(E), CRI(E), CRN(E) 10, 15, 20 ( 4 kW)
B1

L C X

BB B

4 x 14

2 x 14

B B D

42

TM03 4641 3507

2 x 14

TM03 4092 3507

TM03 4642 3507

2 x 14

Pump
Dimensions CR(E), CRI(E), CRN(E) 1s, 1, 3, 5 ( 4 kW), support for base plate and pump head
X [mm] Motor [kW] 0.37 - 0.55 0.75 - 1.1 1.5 - 2.2 3-4 138 B [mm] C [mm] B1-118 B1-124 B1-140 B1-144 D [mm] 45 45 45 45 140 50 105 80 H [mm] L [mm] Connections DIN Oval, PJE, FlexiClamp

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Note: For pump height (B1), see the CR(E), CRI(E), CRN(E) data booklet.

CR(E), CRI(E), CRN(E) 5 (5.5 - 7.5 kW)


CR(E), CRI(E), CRN(E) 5 X [mm] Motor [kW] 5.5 7.5 A [mm] 216 216 AA [mm] 326 326 AAA [mm] 366 366 AB [mm] 276 276 B [mm] 140 140 BB [mm] 180 180 C [mm] B1+119 B1+119 D [mm] 68 68 E [mm] 45 45 F [mm] 138 138 H [mm] 200 200 L [mm] 50 50 Connections DIN 105 Oval 80

Note: For pump height (B1), see the CR(E), CRI(E), CRN(E) data booklet.

CR(E), CRI(E), CRN(E) 10, 15, 20 ( 4 kW), support for base plate and pump head
CR(E), CRI(E), CRN(E) 10 X [mm] Motor [kW] 0.37 - 0.55 0.75 - 1.1 1.5 - 2.2 3-4 170 B [mm] C [mm] B1-125 B1-129 B1-144.5 B1-149.5 D [mm] 45 45 45 45 174 50 110 120 H [mm] L [mm] Connections DIN, oval, PJE, FlexiClamp DIN, oval, PJE, FlexiClamp 15, 20

Pump

Note: For pump height (B1), see the CR(E), CRI(E), CRN(E) data booklet.

CR(E), CRI(E), CRN(E) 10, 15, 20 ( 5.5 kW), support for base plate and motor
CR(E), CRI(E), CRN(E) 10 X [mm] Motor [kW] 5.5 7.5 11 15 18.5 A [mm] 216 216 254 254 254 AA [mm] 326 326 384 384 384 AAA [mm] 366 366 424 424 424 AB [mm] 276 276 334 334 334 B [mm] 140 140 210 210 254 BB [mm] 180 180 260 260 310 C [mm] B1+119 B1+119 B1+138 B1+138 B1+138 D [mm] 68 68 40 40 40 E [mm] 45 45 45 45 45 F [mm] 170 170 170 170 170 H [mm] 200 200 200 200 200 L [mm] 50 50 50 50 50 110 120 Connections DIN, oval, PJE, DIN, oval, PJE, FlexiClamp FlexiClamp 15, 20

43

Pump
CR(E), CRN(E) 32, 45, 64, 90, 120, 150 ( 45 kW), support for base plate and motor

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

CR(E), CRN(E) 32 A [mm] 140 140 160 190 216 216 254 254 254 279 318 318 356 AA [mm] 320 320 340 370 395 395 440 455 455 485 540 540 580 AAA [mm] 380 380 400 430 455 455 500 515 515 545 600 600 640 AB [mm] 220 220 245 275 300 300 340 340 340 365 410 410 450 B [mm] 100 125 140 140 140 140 210 210 254 240 305 305 310 BB [mm] 165 165 180 180 180 180 275 266 310 310 365 365 370 C [mm] B1-261 B1-261 B1-254 B1-247 B1-228 B1-228 B1-209 B1-209 B1-209 B1-196 B1-184 B1-184 B1-168 D [mm] 200 200 190 178 158 158 130 130 130 110 90 90 65 E [mm] 340 340 340 340 340 340 340 340 340 340 340 340 340 290 60 212 177 H [mm] L [mm] 45, 64, 90, 120, 150 X [mm] Motor [kW] 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 Connections DIN DIN

CR, CRN 120, 150 (55 kW), support for base plate and motor
CR, CRN 120, 150 X [mm] Motor [kW] 55 A [mm] 349 AAA [mm] 409 BB [mm] 100 C [mm] B1-137 D [mm] 40 E [mm] 340 H [mm] 290 L [mm] 60 Connections DIN 177

Pump
44

Pump
Belt-driven pumps

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

For extended bearing life, these pulley wheel sizes are recommended:
Type III Pulley head
GR5886 - GR5887

Type IV

Type II

Type I

0.37 - 5.5 [kW] 7.5 - 18.5 [kW] 1.5 - 7.5 [kW] 11 - 45 [kW] CR, CRI, CRN 1s, 1, 3, 5, 10, 15, 20 112-135 2 10, 15, 20 Min. 200 Min. 3 Max. 3000 CR, CRN 32, 45, 64, 90 Min. 160 Min. 2 Min. 200 Min. 3

Pump type Pulley wheel diameter V-belts Pump speed [min-1]

Fig. 56 Belt-driven CR pump

Belt-driven pumps are used in applications for spacesaving reasons or where no electrical power is available. Belt-driven CR pumps are of the same construction as electrically driven pumps. They do, however, have a pulley for connection to for instance an internal combustion motor. Pump range These Grundfos pumps are available as belt-driven pumps:
Pump types CR CRI CRN Available. Belt-driven CR pumps 1s 1 3 5 10 15 20 32 45 64 90 120 150

Sectional drawings CR, CRI, CRN 1s, 1, 3 and 5 (type III)

Pump

CRT 2, 4, 8 and 16 pumps are also available as beltdriven pumps. An additional bearing has been added on top of an existing bearing flange. The two bearings are fitted back-to-back. This bearing design makes it possible to withstand the extra radial forces caused by a pulley. A pulley can be attached to the end of the shaft. Note: The pulley is not supplied with the pump. By means of pulley belts, the pump can be driven by a motor mounted next to it rather than on top of it. The pump can be mounted horizontally or vertically by the extra support plates. The pulley head is positioned on the motor stool where the motor would normally be fitted. By means of the existing holes in the motor stool, the pulley head can be secured to the motor stool with bolts, washers and nuts. The pulley wheel is then attached to the shaft using an appropriate bush and key. CR, CRI, CRN 10, 15 and 20 (type III)
TM03 4137 1706 TM03 4168 1706

45

Pump
CR, CRI, CRN 10, 15 and 20 (type IV)

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

CR, CRN 32, 45, 64 and 90 (type I)

TM03 4169 1706

CR, CRN 32, 45, 64 and 90 (type II)

Pump

46

TM03 4170 1706

TM03 4171 1706

Pump
CR(I) deep-well pumps
CR(I) deep-well pumps are used for deep-well pumping in small water supply systems where water is pumped from depths (HD) down to 90 metres.

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Water is pumped through the pressure pipe (A) and the strainer (B) to the nozzle (C). The water passes the nozzle at high speed and flows into the diffusor (D). Via the strainer (E) and bottom valve (F), water which is to be pumped up is in connection with the chamber (G). From the chamber, it is pressed into the diffusor (D) by the water jet from the nozzle (C). There the two water flows mix, and the velocity is converted into pressure, driving the water up through the riser pipe (H) to the suction port of the pump. Technical data

HD

Maximum system pressure: Maximum ambient temperature: Maximum liquid temperature: Minimum size of borehole
TM03 2954 4905

16 bar +40 C +40 C 3"

Pump range These pumps are available with ejector:


Pump types CR CRI CRN Available. CR deep-well pumps 1s 1 3 5 10 15 20 32 45 64 90 120 150

Fig. 57 System with CR(I) deep-well pump

The pump system consists of a dry-installed CR(I) multistage centrifugal pump connected to a one-size submerged ejector via two pipes. It is advisable to connect a pressure tank to the discharge side of the pump to maintain a suitable pressure at the tapping point.

Use of suction pipe If the well capacity is lower than the pump capacity, dry running of the pump can be prevented by fitting a suction pipe below the ejector. To enable this, the ejector strainer (E) is replaced with a special threaded nipple. Performance curves and technical data For information about the performance curves and technical data of CR deep-well pumps, see page 70 and 112. Ejectors Based on the performance curves on page 70, we offer the following ejectors:
Ejector type Product number 90230045 90230044 90230029 90230022 90230020 90230011

Pump

H A D C B
TM03 2953 4905

G F E

45B 44B 29B 22B 20B 11B

Fig. 58 Sectional drawing of ejector

Contact Grundfos for further information about CR(I) ejector pumps.

47

Pump
Pump rubber parts
We offer pumps with a wide range of customised rubber parts, such as EPDM, FKM, FFKM and FXM to suit your requirements.
Pump type CR, CRI, CRN 1s, 1, 3, 5 CR, CRI, CRN 10, 15, 20 CR, CRN 32, 45, 64, 90 CR, CRN 120, 150
1) 1)

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Bearing flange
To ensure long pump life and reliable operation, a bearing flange can be fitted between the motor and the pump head.

Rubber parts EPDM FKM FFKM FXM

Available. These pumps are fitted with FXM sleeve gaskets. All other rubber parts are of FFKM.

We offer customised rubber parts for these pump types:


Pump type CR(E) CRI(E) CRN(E) Available. 1s 1 3 5 10 15 20 32 45 64 90 120 150

Fig. 59 Bearing flange

Empty chambers
We offer custom-built pumps with empty chambers designed to meet your specific duty point! CR pumps with a predefined number of chambers are selected in the standard product range. See for instance the performance curves of CR 20-14 and CR 20-17 on page 75. In order to avoid the selection of a pump too large for your duty point, we offer custom-built pumps fitted empty chambers to enable an optimum match. We offer pumps with empty chambers for the following pump types.
Pump type CR(E) CRI(E) CRN(E) Available. 1s 1 3 5 10 15 20 32 45 64 90 120 150

Key
Pos. 1 2 3 Designation Motor Bearing flange Pump head

Pump

A bearing flange is an additional flange with an oversize ball bearing to absorb axial forces in both directions. The coupling is part of the bearing flange fitted to obtain optimum alignment. Note: The bearing flange requires a motor with keyway and ball bearings according to IEC 34 and NEMA. A bearing flange is used in two situations: 1. A standard motor with standard ball bearing is required. The bearing flange absorbs the hydraulic load from the pump, ensuring an acceptable motor bearing life. 2. The pump is to run at a higher inlet pressure than the maximum pressure recommended. Note: For motor sizes above 11 kW, the bearing flange is equipped with grease nipples and must be lubricated regularly. Please follow the instructions on the bearing flange.

Note: CRT(E) 2, 4, 8 and 16 are also available as custom-built pumps with empty chambers.

48

TM03 4062 1406

Pump
Pump range The following pump types are available with bearing flange:
Pump type CR(E) CRI(E) CRN(E) Available. 1s 1 3 5 10 15 20 32 45 64 90 120 150

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

CR, CRN 32, 45, 64, 90 (> 7.5 kW)

Note: CRT(E) 2, 4, 8 and 16 are also available as custom-built pumps with bearing flange. Bearing flange for CR pumps CR, CRI, CRN 1s, 1, 3, 5 ( 7.5 kW) CR, CRI, CRN 10, 15, 20 ( 4 kW)

Dimensions The following additional heights must be added to the total height of the pump. CR, CRI, CRN 1s, 1, 3, 5, 10, 15, 20
Motor power IEC [kW] 0.37 - 0.55 0.75 - 1.1 1.5 - 4.0 5.5 - 7.5 11.0 - 18.5 NEMA [hp] 0.33 - 2.0 40 45 135 3.0 - 10 15 - 40
1) 2)

Additional height [mm] 31 32 40 23 1) / 150 2) 150

CR, CRI, CRN 10, 15, 20 ( 5.5 kW)

TM02 7436 3403

TM01 4353 0199

Pump

CR, CRI, CRN 1s, 1, 3, 5 CR, CRI, CRN 10, 15, 20.

CR, CRN 32, 45, 64, 90


Motor power
TM02 7437 3403

Additional height [mm] 23 20 22 17

IEC [kW] 3.0 - 7.5 11.0 - 45 NEMA [hp] 3.0 - 10.0 15.0 - 60.0

CR, CRN 32, 45, 64, 90 ( 7.5 kW)

For information about the total height of a given CR pump, see these data booklets:
TM01 4352 0199

CR, CRI, CRN, CRE, CRIE, CRNE CRT, CRTE CR, CRN high pressure. The above data booklets are available in WebCAPS. See page 160.

49

Pump
Support bearings
We offer custom-built pumps with support bearings of bronze for corrosive applications for these pump types:
Pump type CR(E) CRI(E) CRN(E) Available. 1s 1 3 5 10 15 20 32 45 64 90 120 150

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Dry-running protection
LiqTec

Bearing material
We offer pumps with a wide range of customised bearing materials such as bronze, tungsten carbide and carbon-filled PTFE to suit your requirements.
Pump size CR, CRN 1, 3, 5, 10, 15, 20 CR, CRN 32, 45, 64, 90 Bearing material Bronze/tungsten carbide EPDM/tungsten carbide Silicon carbide/tungsten carbide

Fig. 60 LiqTec dry-running protection device

The Grundfos LiqTec immediately cuts off the pilot current to the motor protection relay in these cases: There is no liquid in the pump. The liquid temperature exceeds +130 5 C. The sensor, sensor cable, electronic unit or power supply fails. When connected to the PTC sensors in the motor, the LiqTec also protects the motor against overheating. The sensor is easily inserted through the " connection in the pump head close to the shaft seal. It can, however, also be used externally. The LiqTec sends a heat impulse through the sensor, measuring the temperature of the sensor. Liquid in the pump cools the sensor as well as the shaft seal and other pump parts. If there is no liquid present, the LiqTec detects a high temperature in the sensor and cuts out the pump immediately to prevent damage. The LiqTec also prevents excessive liquid temperatures from damaging the pump. If the LiqTec senses a liquid temperature above +130 C, it cuts out the pump immediately. The LiqTec is a fail-safe device, meaning that the pump stops as soon as the sensor detects an error on the sensor cable or the electronics, or if the power supply of the control unit is switched off. Restarting of the pump can be automatic or manual when the sensor detects liquid in the pump again. Remote restarting is possible via a digital input. The electronic control unit can also be connected to the PTC sensor measuring the motor temperature. In case of overheating of the motor, the system cuts out the pump.

We offer customised rubber parts for these pump types:


Pump type CR(E) CRI(E) CRN(E) 1s 1 3 5 10 15 20 32 45 64 90 120 150

Pump

Available.

Pump head positions


As standard, the pump head is mounted so that the air vent screw is in line with the discharge port. The pump head can be mounted in three other positions in steps of 90. Note: The air vent of horizontal pumps must always point upwards.

Customised nameplate
We offer additional customised nameplates attached to the pump: A nameplate delivered by you. A Grundfos nameplate customised in terms of a specific duty point. A Grundfos nameplate with a tag number. Note: Grundfos standard nameplate is always fitted on the pump.

50

GR9415

Pump
Figures 61 and 62 show installation examples.
L1 L2 L3 N Sensor

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Dimensions 116 x 90 mm. The LiqTec can be fitted to a DIN rail in a control cabinet. Technical data
K1

Supply voltage Power consumption Max. pressure

1 x 80-130 V or 1 x 200-240 V 5W 40 bar 20 C/120 C 50 C 99 % IPX0 Any water-based liquid handled by Grundfos pumps 5 m 1)

T+

T+

M
3

Min./max. liquid temperature Max. ambient temperature Humidity Enclosure class Pumped liquid Cable length
1) 15-metres

External restart

T+

Brown/Black Blue White

cable is available on request.

Connections
CR pumps with TriClamp connection A base with TriClamp connection is of hygienic design with a sanitary coupling for use in the pharmaceutical and food and beverage industry. A set consists of one clamping ring, one gasket and one pipe stub. The connection is in accordance with EN/DIN 32676. Dimensions
L1 L2 L3

K1

Fig. 61 LiqTec connected to a standard motor

TM03 0112 4004

Pump

Sensor

50. 5

4 x 13
TM03 4648 3507

T+

MGE
3

50

T+

22

External restart
Brown/Black Blue White

T+

100 150 162

32 180 210

Fig. 63 TriClamp connection for CRI, CRN 1s, 1, 3 and 5

202 64

200
TM04 4472 1309

215 248

80 on CRI, CRN 10 CRI, CRI, CRN 20: 90 90 on CRN 15, 15 and 20

CRI, CRN 10: 80

Terminals in MGE motor


2 3 9

Fig. 64 TriClamp connection for CRI, CRN 10, 15 and 20

Fig. 62 LiqTec connected to an MGE motor

TM03 4649 2406

130

26

4 x 13

50

51

Pump
Clamping ring
TM03 4645 2406

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Port
TM03 4646 2406

Gasket
TM03 4647 2406

Pump type CRI(E), CRN(E) 1s, 1, 3, 5 CRI(E), CRN(E) 10, 15, 20

Nominal diameter [mm] 38.0 51.0

A [mm] 92.0 104.4

B [mm] 59.5 74.0

A [mm] 21.5 21.5

B [mm] 50.5 64.0

C [mm] 35.6 48.6

D [mm] 38.6 51.6

A [mm] 35.3 48.0

B [mm] 50.5 64.0

The clamping ring is made of stainless steel EN/DIN 1.4301/AISI 304 The port is made of stainless steel EN/DIN 1.4401/AISI 316 The gasket is made of PTFE or EPDM.
Connection Pump type CRI(E), CRN(E) 1, 3, 5 CRI(E), CRN(E) 10, 15, 20 Pipework connection DN 32 Stainless steel DN 50 Connection material Gaskets EPDM PTFE EPDM PTFE 16 Pressure [bar] Coupling sets required 2 2 2 2 Product number 96515374 96515375 96515376 96515377

We offer TriClamp connections for these pump types:


Pump type 1s 1 3 5 10 15 20 32 45 64 90 120 150

Pump

CR(E) CRI(E) CRN(E) Available.

CR pumps with connection to EN/DIN 11851 A base with connections according to EN/DIN 11851 is of hygienic design for use in dairies and in the food and beverage industry. A set consists of one pipe stub with external thread designed for a flexiClamp base with union connection.

52

GR5840

Pump
Dimensions
M10 x 40 22 4 x 13
TM03 4682 2506

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

50

100 150 321

75 180 210

Fig. 65 Connection to EN/DIN 11851 for CRI, CRN 1s, 1, 3 and 5

M10 x 40
26

4 x 13

CRI, CRN CRN80 80 on CRI, 10: 10 CRI, CRN CRN20: and 20 90 on CRI, 15, 15 90

Fig. 66 Connection to EN/DIN 11851 for CRI, CRN 10, 15 and 20


Pressure [bar]

Pump type CRI(E), CRN(E) 1, 3, 5 CRI(E), CRN(E) 10, 15, 20

Pipework connection DN 32

Connection material

TM03 4683 2506

130 200 394

100 215 248

Gaskets EPDM

Coupling sets required 2

Product number 96551445 96551447 96551549 96551570

Stainless steel DN 50

FKM EPDM FKM

16

2 2 2

Pump

We offer the above connections for these pump types:


Pump type CR(E) CRI(E) CRN(E) Available. 1s 1 3 5 10 15 20 32 45 64 90 120 150

CR pump with PJE coupling A base with PJE couplings is designed for use in a wide range of industrial applications. A set consists of two coupling halves, one gasket, one coupling liner for welding and bolts and nuts.

53

Pump
Dimensions
88.9

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

4x 14
105 30
TM03 4719 2506

170 226 320

240 298

Fig. 67 PJE coupling for CRN 32


114.3

4x 14 140 45
TM03 4720 2506
4x 14 4x 14

190 251 365

266 331

Fig. 68 PJE coupling for CRN 45

114.3 45

Pump

190 251 365

266 331

Fig. 69 PJE coupling for CRN 64

114.3

45

199 261 380

280 348

Fig. 70 PJE coupling for CRN 90

Fig. 71 PJE coupling for CRN 120 and 150

54

TM04 4558 1609

TM03 4722 2506

140

TM03 4721 2506

140

Pump

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Part
TM00 3712 0894

Designation

Designed for pump type CRN 32

Rubber parts NBR seal 3"

Product number 00ID7664

Victaulic type 77 coupling 3": 89 mm 4": 114 mm

CRN 45, 64, 90, 120, 150

NBR seal 4"

96415463

TM00 3709 0894

CRN 32 Victaulic coupling liner for welding CRN 45, 64, 90, 120, 150

N version 3"

00150574

N version 4"

96416743

We offer PJE connections for these pump types:


Pump type CR(E) CRI(E) CRN(E) Available. 1s 1 3 5 10 15 20 32 45 64 90 120 150

Customer-specified connections We offer a wide range of customer-specified connections for these pump types:
Pump type CR(E) CRI(E) CRN(E) 1s 1 3 5 10 15 20 32 45 64 90 120 150

Note: PJE connections are available on CRI, CRN, 1s, 1, 3, 5, 10, 15 and 20 pumps as standard. CR pumps with ANSI or JIS connection We offer pumps with ANSI or JIS flanges for these pump types:
Pump type CR(E) CRI(E) CRN(E) Available. 1s 1 3 5 10 15 20 32 45 64 90 120 150

Contact Grundfos for further information about customer-specified connections. We also offer these connections: oval flanges (BSP) DIN flanges PJE couplings (Victaulic) for CRN(E) clamp couplings (L-couplings) unions (+GF+). For further information about these connections, see these data booklets: CR, CRI, CRN, CRE, CRIE, CRNE CR, CRN high pressure CRT, CRTE.

Pump

Note: ANSI and JIS connections are available on CRI, CRN, 1s, 1, 3, 5, 10, 15 and 20 pumps as standard. Technical data
Connection ANSI JIS Max. rated pressure Class 300 30 K

All data booklets are available in WebCAPS. See page 160.

Note: CR(E), CRI(E), CRN(E) 1s, 1, 3, 5 and 10 pumps are available with flanges that meet the requirements of both DIN, ANSI and JIS as standard. The dimensions of pumps with DIN, ANSI or JIS flanges are the same, apart from the flange bolt holes.

55

Certificates
CR pumps with certificates
We offer certificates for a number of applications requiring documentation on the pump quality. Examples: pharmaceutical industries maritime and offshore applications potentially explosive environments energy and power suppliers. Note: The certificates must be ordered with the pump. These pumps are available with certificates:
Pump type CR(E) CRI(E) CRN(E) Available. 1s 1 3 5 10 15 20 32 45 64 90 120 150

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Note: Certified and approved CRT(E) 2, 4, 8 and 16 pumps are also available. Certificates
Certificate Certificate of compliance with the order Test certificate. Non-specific inspection and testing Inspection certificate 3.1 Description According to EN 10204, 2.1. Grundfos document certifying that the pump supplied is in compliance with the order specifications. According to EN 10204, 2.2. Certificate with inspection and test results of a non-specific pump. Grundfos document certifying that the pump supplied is in compliance with the order specifications. Inspection and test results are mentioned in the certificate. Grundfos document certifying that the pump supplied is in compliance with the order specifications. Inspection and test results are mentioned in the certificate. Certificate from the surveyor is included. We offer the following inspection certificates: Lloyds Register of Shipping (LRS) Det Norske Veritas (DNV) Germanischer Lloyd (GL) Bureau Veritas (BV) American Bureau of Shipping (ABS) Registro Italiano Navale Agenture (RINA) China Classification Society (CCS) Russian maritime register of Shipping (RS) Biro Klassifikasio Indonesia (BKI) United States Coast Guard (USCG) Nippon Kaiji Koykai (NKK) Certifies that the main components of the specific pump are manufactured by Grundfos, and that the pump has been QH-tested, inspected and conforms to the full requirements of the appropriate catalogues, drawings and specifications. Certifies the material used for the main components of the specific pump. Certifies the material used for the main components of the specific pump. A material certificate, EN 10204, 3.1, will be supplied for each main component. Certifies a test point specified by the customer. Issued according to ISO 9906 concerning "Duty point verification". Shows the measured roughness of the cast pump base of the specific pump. The report indicates the values measured at the base inlet and outlet according to ISO 1302. Vibration report indicating the values measured during the performance test of the specific pump according to ISO 10816. Shows the performance test of the specific motor, including power output, current, temperature, stator windings resistance and insulation test. Confirms that the specific pump has been cleaned and dried, and how it was done. Confirms that the specific pump has been electro-polished. The maximum surface roughness is specified in the report. Confirms that the specific pump is ATEX-approved according to the EU directive 94/9/EC, the "ATEX directive".

Inspection certificate

Standard test report Material specification report Material specification report with certificate from raw material supplier Duty-point verification report Surface-roughness Vibration report Motor test report Cleaned and dried pump Electro-polished pump ATEX-approved pump

Examples of the certificates are shown on pages 57 to 60. Note: Other certificates are available on request.

56

Certificates
Examples of certificates
Certificate of compliance with the order

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Test certificate

Certificate of compliance with the order


EN 10204 2.1

Test certificate Non-specific inspection and testing


EN 10204 2.2

Customer name Customer order no. Customer Tag no. GRUNDFOS order no. Product type

Customer name Customer order no. Customer TAG no. GRUNDFOS order no.

We the undersigned hereby guarantee and certify that the materials and/or parts for the above mentioned product were manufactured, tested, inspected, and conform to the full requirements of the appropriate catalogues, drawings and/or specifications relative thereto.

Pump Pump type Motor make Flow Head Power P2 Voltage Frequency Full load current Motor speed

Part number Pa rt num b e r m3/h m kW V Hz A min -1

We the undersigned hereby guarantee and certify that the materials and/or parts for the above mentioned product were manufactured, tested, inspected, and conform to the full requirements of the appropriate catalogues, drawings and / or specifications relative thereto.

TM03 4165 1706

GRUNDFOS
Date: Signature: Name: Dept.:
Part no. 96 50 78 95/1001002

GRUNDFOS
Date: Signature: Name: Dept.:
Part no 96 50 78 96/1001002

Inspection certificate 3.1

Inspection certificate

Inspection certificate.
EN 10204 3.1
Manufactured by GRUNDFOS order no. GRUNDFOS DUT id. Customer order no. Customer name and address Shipyard / factory Ship / new building Customer TAG no. Classifying society Pump Pump type Part number Serial no. Flow rate (m3/h) Head (m) Max. ope. P/t (bar / C) Din / W. - No. Base/Pump head cover Impeller/guidevanes Shaft/sleeve Customers requirements Flow rate (m3/h) Test result ref. requirements Q(m3/h) H(m) Hydrostatic test
-1

Inspection certificate.
Russian Maritime Register of Shipping

GRUNDFOS authorized department Motor Make Part number Serial No. P2 (kW) Voltage (V) Current (A) n(min-1) Frequency (Hz) Insulation class Power factor

Manufactured by GRUNDFOS order no. GRUNDFOS DUT id. Customer order no. Customer name and address Shipyard / factory Ship / new building Customer TAG no. Classifying society Pump Pump type Part number Serial no. Flow rate (m3/h) Head (m) Max. ope. P/t (bar / C) Service Medium

Russian Maritime Register of Shipping ( RS ) Motor Make Part number Serial No. P2 (kW) Voltage (V) Current (A) n(min-1) Frequency (Hz) Insulation class Power factor

Din / W. - No. Base/Pump head cover Impeller/guidevanes Shaft/sleeve Customers requirements Flow rate (m3/h) Test result ref. requirements Q(m3/h) H(m) Hydrostatic test The pump has been marked
-1

Head (m)

n(min )

I(A)

P1(kW)

Head (m)

Bar no leaks or deformation observed

n(min )

I(A)

P1(kW)

Bar no leaks or deformation observed

TM03 4162 3607

GRUNDFOS
Date: Signature: Name: Dept.:
Part no. 96 50 78 97/1014142

Surveyor signature: Tested date:

GRUNDFOS
Date: Signature: Name: Dept.:
Part no. 96 50 79 25/1014142

TM03 4156 3607

TM03 4163 1706

57

Certificates

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Standard test report

Material specification report

Standard test report


Customer name Customer order no. Customer TAG no. GRUNDFOS order no. Pump type GRUNDFOS DUT id. Part number Production code

Material specification report.

Customer name Customer order no. Customer Tag no. GRUNDFOS order no. Product type GRUNDFOS DUT id. Part number We the undersigned hereby guarantee and certify that the materials and/or parts for the above mentioned product were manufactured by GRUNDFOS, tested, inspected, and conform to the full requirements of the appropriate catalogues, drawings and/or specifications relative thereto. The attached test result is from the above mentioned pump.

Pump Pump head Pump head cover Shaft Impeller Chamber Outer sleeve Base

Materials

DIN W.-Nr.

AISI / ASTM

We the undersigned hereby guarantee and certify that the materials and/or parts for the above mentioned product were manufactured, tested, inspected, and conform to the full requirements of the appropriate catalogues, drawings and/or specifications relative thereto.

TM03 4143 1706

GRUNDFOS
Date: Signature: Name: Dept.:
Part no. 96 50 79 30 P01 /A72775

GRUNDFOS
Date: Signature: Name: Dept.:
Part no 96 50 79 28/A72775

Material specification report with certificate from raw material supplier

Duty point verification report

Material specification report with EN10204 3.1 material certificate from raw material supplier

Duty point verification report

Customer name Customer order no. Customer TAG no. GRUNDFOS order no. Pump type GRUNDFOS DUT id. Part number Production code

Customer name Customer order no. Customer Tag no. GRUNDFOS order no. Product type GRUNDFOS DUT id. Part number We the undersigned hereby guarantee and certify that the materials and/or parts for the above mentioned product were manufactured by GRUNDFOS, tested, inspected, and conform to the full requirements of the appropriate catalogues, drawings and/or specifications relative thereto.

Pump Pump head Pump head cover Shaft Impeller Chamber Outer sleeve Base

Raw materiel no.

Supplier certificate no.

We the undersigned hereby guarantee and certify that the materials and/or parts for the above mentioned product were manufactured, tested, inspected, and conform to the full requirements of the appropriate catalogues, drawings and/or specifications relative thereto.

TM03 4149 3607

GRUNDFOS
Date: Signature: Name: Dept.:
Part no 96 50 79 29/A72775

GRUNDFOS
Date: Signature: Name: Dept.:
Part no. 96 53 96 99 /A72775

58

TM03 4148 1706

TM03 4150 1706

Certificates

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Surface-roughness

Vibration report

Vibration report
Surface roughness
According to ISO 1302 Customer name Customer order no. Customer TAG no. GRUNDFOS order no. Pump type GRUNDFOS DUT id. Part number CRN base part number The surface roughness is measured as the maximum roughness of the CRN inlet and outlet surface.

According to ISO 10816 Customer name Customer order no. Customer TAG no. GRUNDFOS order no. GRUNDFOS DUT id. Measured object Pump type P2 (kW) Number of poles Test conditions The pump is floormounted on vibration absorbers. Remarks

Part number Frequency (Hz) Serial no.

Voltage (V) Frequency: (Hz) Flow (m/h) Head (m) For vibration velocity measurement positions, see figure.

Result of measurement:
Pos RMS vibration velocity (mm/s)

Typical zone boundary limits 1 2 3 4 5 6 7 8 9


RMS vibration Class I Class II velocity (mm/s) 0.28 A 0.45 A 0.71 1.12 B 1.8 B 2.8 C 4.5 C 7.1 11.2 D 18 D 28 45 The machine classifications are as follows: Class I: Individual parts of engines and machines, integrally connected to the complete machine in its normal operating condition. (Production electrical motors of up to 15 kW are typical examples of machines in this category.) Class II: Medium-sized machines (typically electrical motors with 15 kW to 75 kW output) without special foundations, rigidly mounted engines or machines (up to 300 kW) on special foundations.

Surface Treatment None E lec t r o-p ol is h ed

Mea sure d val u es A R max RA RZ Me a s ur ed v a l ue s B R max RA RZ

[m] [m] [m]

[m] [m] [m]

Roughness value RA [m] 50 25 1 2. 5 6. 3 3.2 1.6 0.8 0.4 0 .2 0.1 0 . 05 0 . 0 25

Roughness degree N 12 N 11 N 10 N9 N8 N7 N6 N5 N4 N3 N2 N1

TM03 4147 3607

GRUNDFOS Date:
Signature: Name: Dept.:
Part no 96 50 79 31/A72775

GRUNDFOS
Date: Signature: Name: Dept.:
Part no 96 50 79 32/A72775

26-Apr-06

Motor test report

Clean and dried pump

Motor test report

Cleaned and dried pump

Customer name Customer order no. Customer Tag no. GRUNDFOS order no. GRUNDFOS DUT id. Part number Motor no. Motor serie no. We the undersigned hereby guarantee and certify that the above motor has been tested. The performance of the motor can be seen in the motor test report on the next page.

Customer name Customer order no. Customer TAG no. GRUNDFOS order no. Pump type GRUNDFOS DUT id. Part number Production code

GRUNDFOS hereby confirms that the pump mentioned above is manufactured according the specifications mentioned in the CR, CRI, CRN Custom-built pumps data booklet. This means that prior to assembly, pump components are washed in pure, hot soap water, rinsed in deionized water and dried. The pump is wrapped in a plastic bag before being packed. The pump has not been performance-tested.

TM03 4146 1706

GRUNDFOS
Date: Signature: Name: Dept.:
Part no. 96 50 79 33 /A72775

GRUNDFOS Date: Signature: Name: Dept.:


Part no 96 50 79 34/A72775

TM03 4145 1706

TM03 4167 1706

59

Certificates

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Electro-polished pump

ATEX-approved pump

Electro-polished pump
Customer name Customer order no. Customer TAG no. GRUNDFOS order no. Pump type GRUNDFOS DUT id. Part number Production code Grundfos hereby conforms that the pump mentioned above is manufactured according to the specifications mention in the CR, CRI, CRN Custom-built pumps data booklet. This means that prior to asembly, pump components are electro-polished in a mixture of sulphuric acid and phosphoric acid. Finally the components are passivated in nitric acid. The CRN1s, 1, 3, 5, 10, 15, and 20 casted parts are all mechanically polished before being electropolished. The pump will then optain following surface roughness; ________________________________________________________________________ Pump type Stainless steel Surface plate and other roughness non casted parts ( m ) ________________________________________________________________________ CRN1s, 1, 3, 5 * * equal to or below 0,8 _______________________________________________________________________ CRN10, 15, 20 * * equal to or below 0,8 ________________________________________________________________________ CRN32, 45, 64, 90 * * between 10 15 equal to or below 0,8 Stainless steel casted parts

ATEX-approved pump

Customer name Customer order no. Customer TAG no. GRUNDFOS order no. Pump type GRUNDFOS DUT id. Part number Production code Pump serial no. Motor serial no. ATEX approval of pump Technical file no.

96499604

GRUNDFOS hereby confirms that the pump mentioned above is manufactured according the ATEX directive. This means the pump is conformity with the ATEX 94/9EEC (ATEX 100) appendix VIII directive as mentioned in the ATEX Supplement to installation and operating instructions supplied with the pump.

TM03 4144 1706

GRUNDFOS Date: Signature: Name: Dept.:


Part no 96 50 79 35/A72775

GRUNDFOS Date: Signature: Name: Dept.:


Part no 96 51 22 40/A72775

60

TM03 4166 1706

CRE pump solutions

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Fig. 73 shows the hardware combination of a standard CRE pump with extended functional module.

Control panel
GR9033

Fig. 72 Motors for CRE, CRIE, CRNE, CRTE pumps

Extended functional module (MGE I/O) Bus communication module (GENI/RS485)

Besides continuously variable performance, CRE, CRIE, CRNE, CRTE pumps offer a number of advantages depending on the hardware and software combinations of the motor. We offer the following CRE pump solutions: CRE pump with extended functional module customised CRE pump solutions. CRE pumps are not dependent on the frequency of the supply voltage and are designed for operation at frequencies between 1500 min-1 and 6000 min-1. This offers a number of advantages: compact pump higher performance in relation to physical size larger dynamic range
Group 2

Fig. 73 Hardware combination of a standard CRE pump

Fig. 74 shows the terminal box of the motor containing a basic controller, an extended functional module and a GENIbus communication module.

less noise at reduced speed more gentle handling of the pumped liquid at reduced speed. The speed may be chosen freely, taking into consideration the maximum motor load and the hydraulic properties of the pump. Pumps can be delivered with oversize or undersize motors depending on load profile. Ball bearing configuration can also be altered to fit load and demands.
NC C NO

L1 L2 L3

TM03 8612 2007

Terminal box incl. basic frequency converter and basic controller

Group 3

E-pump solutions

CRE pump with extended functional module


CRE pumps with extended functional module enable the control of more than one parameter, such as pressure, differential pressure, temperature, differential temperature or flow rate. As standard, CRE, CRIE, CRNE, CRTE pumps are equipped with these parts: a control panel on the terminal box front. a basic controller with 1 digital input for start/stop, 1 analog setpoint input, etc. a functional module with 3 digital inputs, 1 analog sensor input, 1 analog sensor output and 24 V supply. a GENIbus communication module. See also page 63. Note: If the GENIbus communication module is not required, we offer motors without the module. The version is the same for CRE, CRIE, CRNE, CRTE pumps with and without sensor.

0-10 V 0/4-20 mA 4-20 mA

1/0 1/0 1/0

Group 1

13 12 11 10 1 9 8 7

B Y A

STOP RUN 0/4-20 mA 0-10 V


10K

*)

6 5 4 3 2

*) 0.37 - 7.5 kW only: The changeover follows the function of digital input 4. Factory setting: Not active (NO) <-> active (NC)

Fig. 74 Custom-built CRE pump with extended functional module (0.37 - 22 kW)

TM02 9032 1504

61

CRE pump solutions


Key
Group no. Terminals Basic controller 2 3 4 5 6 13 12 1 11 10 1 9 8 7 B Y A 2 NC, C, NO Voltage supply 3 L1, N, PE: L1, L2, L3: Single-phase motor Three-phase motor Start/stop GND Setpoint input +10 V GND GND Analog output (0-10 V) Digital input 4 Digital input 3 Digital input 2 GND +24 V Sensor input RS-485B Screen RS-485A Outputs for signal relay Description

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Fig. 75 shows the hardware combination of the motor for a custom-built CRE pump.

Functional module

Functional module: Extended module (MGE I/O) Multi-pump module (Multi-E) GENIbus communication module (GENI/RS485)

GENIbus communication module

Terminal box incl. basic frequency converter and basic controller

Potential-free signal relay

Motor

Customised CRE pump solutions


As an alternative to the other CRE pump solutions, we offer CRE pump solutions for your requirements! It is possible to put together CRE pumps by selection/ deselection: Selection of a control panel on the front of the terminal box of the motor. Note: If the control panel is deselected, a blanking plate is fitted, and the motor cannot communicate with the R100 remote control.

Fig. 75 Motor combination of custom-built CRE pumps

Control panel The control panel on the front of the terminal box of the motor enables setpoint setting and communication.

E-pump solutions

Selection/deselection of a GENIbus communication module. See also page 63. Our CRE pump solutions make it possible to read in customised configuration files, the so-called gsc files, for optimum operation. The configuration files can be read into the motor during the final test at Grundfos, at start-up or in connection with service by means of Grundfos PC Tool products. Note: When configuration files have been read in, it is still possible to make adjustments. Adjustments can be made by means of the R100 remote control, control panel or PC Tool products. See page 65.
Three-phase motor Single-phase motor

Fig. 76 Buttons and for manual setting of the setpoint of the pump

62

TM02 8513 0304 - TM00 7600 0304

Selection of a multi-pump functional module, reduced functional module or other application-specific add-on cards. Note: The motor can only contain one functional module.

TM03 4114 1606

CRE pump solutions

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

MPC or another unit Service PC

TM02 0936 0501

GENIbus

Fig. 77 Communication with the CRE pump by means of the R100 remote control
TM04 4591 1709

The R100 remote control is based on IR communication and is to be pointed at the control panel of the motor during communication. If a motor without control panel is ordered, it is supplied with a blanking plate. See fig. 78. Note: Motors with blanking plate cannot communicate with Grundfos R100.

Fig. 79 Internal bus communication


Superior control system

Blanking plate
PROFIBUS or another protocol Gateway

GR4345

GENIbus

Fig. 78 Motor without control panel

GENIbus communication module The GENIbus communication module enables communication in the following ways: internal bus communication between two or more Grundfos units (GENIbus-based network) external bus communication via a gateway between a Grundfos unit and an external unit, for instance a computer or superior control system (GENIbus to another network protocol).
Fig. 80 External bus communication

E-pump solutions

Gateways can convert GENIbus to other bus protocols.


Third-party gateway Must support GENIbus Grundfos gateway solutions Bus protocol G100 x x x x x x 100 150 200 250 270 G10-LON x x CIU/CIM

LonMark PROFIBUS ModBUS Interbus S. GSM GRM *)

*) Grundfos Remote Monitoring. GRM makes it possible to access pump data on the web. Connection to GRM server is done via SMS or GPRS.

GENIbus is an open protocol which can be implemented into third-party SCADA systems. Contact Grundfos for documentation.

63

CRE pump solutions


Possible functions The table shows the possible functions of the individual functional modules.
Extended functional module Digital input 1 Start/stop Digital input 2, 3 and 4 Start/stop Deactivation of input (not active) Maximum pressure Minimum pressure Reverse operation Reset alarm External fault Flow switch Emergency operation Predefined speed Analog output Deactivation of output (not active) Actual speed Actual sensor value Actual setpoint value Actual motor current Actual motor load Actual frequency The function is available.

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Setpoint signals Potentiometer 0-10 VDC, 10 k (via internal voltage supply). Screened cable: 0.5 - 1.5 mm2 / 20-16 AWG. Maximum cable length: 100 m. Voltage signal 0-10 VDC, Ri > 50 k. Tolerance: + 0 %/ 3 % at maximum voltage signal. Screened cable: 0.5 - 1.5 mm2 / 28-16 AWG. Maximum cable length: 100 m. Current signal DC 0-20 mA/4-20 mA, Ri = 250 . Tolerance: + 0 %/ 3 % at maximum current signal. Screened cable: 0.25 - 1.5 mm2 / 24-16 AWG. Maximum cable length: 500 m. Sensor signals Voltage signal 0-10 VDC, Ri > 50 k (via internal voltage supply). Tolerance: + 0 %/ 3 % at maximum voltage signal. Screened cable: 0.5 - 1.5 mm2 / 28-16 AWG. Maximum cable length: 100 m. Current signal DC 0-20 mA/4-20 mA, Ri = 250 . Tolerance: + 0 %/ 3 % at maximum current signal. Screened cable: 0.25 - 1.5 mm2 / 24-16 AWG. Maximum cable length: 500 m. Internal power supplies 10 V power supply for external potentiometer: Max. load: 2.5 mA. Short-circuit protected. 24 V power supply for sensors: Max. load: 40 mA. Short-circuit protected. Signal relay output Potential-free changeover contact. Maximum contact load: 250 VAC, 2 A, cos 0.3 - 1. Minimum contact load: 5 VDC, 10 mA. Screened cable: 0.5 - 2.5 mm2 / 20-14 AWG. Maximum cable length: 500 m. Bus input Grundfos bus protocol, GENIbus protocol, RS-485. Screened 3-core cable: 0.2 - 1.5 mm2 / 28-16 AWG. Maximum cable length: 500 m.

Connection of signal transmitters to CRE, CRIE, CRNE, CRTE pumps The functional module enables connection of a number of signal transmitters. Examples: pressure sensors differential pressure sensors temperature sensors

E-pump solutions

differential temperature sensors pH meters flowmeters level sensors. Any signal transmitters complying with the values and limits mentioned on the next page may be connected to the pump. Technical data Inputs/output Start/stop External potential-free contact. Voltage: 5 VDC. Current: < 5 mA. Screened cable: 0.25 - 1.5 mm2 / 24-16 AWG. Digital External potential-free contact. Voltage: 5 VDC. Current: < 5 mA. Screened cable: 0.25 - 1.5 mm2 / 24-16 AWG.

64

CRE pump solutions


Grundfos PC Tool E-products Connection of Grundfos PC Tool E-products offers a number of advantages during commissioning, operation and service of E-pumps. PC tool E-products enables these functions: monitoring of operational status of your E-product standard configuration of E-products custom configuration of E-products saving of logged data from E-products. Via the PC Tool, it is possible to download special predefined configuration files (gsc files) to the pump. The configuration files may contain application-optimised operating parameters based on your specifications! Note: When configuration files have been read in, it is still possible to make adjustments. Description The Grundfos PC Tool E-products is a common user platform/user interface used throughout the entire production process of an E-pump. Furthermore, PC Tool E-products can be used by the customer for setting up, commissioning and servicing the E-pump.

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

TM03 9290 3707

E-pump solutions

Fig. 81 PC Tool E-products used in production and on site by the customer

The Grundfos PC Tool E-products thus enables configuration or reconfiguration of your product to optimise it to exactly your application. And PC Tool E-products is indispensable for fault finding and service. The software for Grundfos PC Tool E-products must be ordered with the PC Tool Link package which contains hardware and cables. Contact Grundfos for further information.

65

CRE pump solutions

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Fig. 82 PC Tool interface

E-pump solutions

Fig. 83 Monitoring function

66

TM04 4607 1809

TM03 3712 0806

How to read the curve charts


CR deep-well 2 1
HD [m]
100 CR(I) 5-15 90 80 70 CR(I) 5-11 60 CR(I) 5-9 50 40 30 20 10 0 0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 CR(I) 5-13 No. 11B No. 29B No. 20B No. 22B No. 44B No. 45B

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Q [m/h] Q [l/s]
TM01 9129 0303

0.0

0.1

0.2

0.3

0.4

0.5

4
Fig. 84 Example of curve chart of CR deep-well
Pos. 1 2 3 4 Description The y-axis indicates the suction depth, HD, in metres. Ejector numbers. QH curve of the individual pump.The bold curves indicate the recommended performance range for best efficiency. The x-axis indicates the flow rate in m 3/h and l/s.

67

How to read the curve charts


CR low-NPSH and CR pumps with 4-pole motor

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

p [kPa]

H [m]
280 260 -14 -13 -12 -11 -10 -9 -8 -8-2 140 -7 -7-2 -6 -6-2 100 -5 -5-2 -4 -4-2 60 -3 -3-2 -2 -14-2 -13-2 -12-2 -11-2 -10-2 -9-2

CR, CRN 32
50 Hz
ISO 9906 Annex A

2400

240 220

1
2000

200 180

1600

160

1200

120

800

80

400

40 20

0 0 4 8 12 16 20 24 28 32 36

Q [m/h] Q [l/s]
P21/1n

10

P2 [kW]

Eta [%]
80 60

2.8 2.1 1.4 0.7 0.0 0 4 8 12 16 20 24

Eta

P21/1 P22/3

40 20 0

28

32

36

p H [kPa] [m]
240 160 80 0 24 16

Q [m/h]
NPSH

QH 2900 rpm1/1n QH 2900 rpm1/1

NPSH [m]
6 4

QH 2900 rpm2/3 8 Low NPSH 0 0 4 8 12 16 20 24 28 32 36 0 2

Q [m/h]

7
Fig. 85 Example of curve chart of CR low-NPSH
Pos. 1 2 3 4 5 6 7 Description Number of stages. First figure: Number of stages. Second figure: Number of reduced-diameter impellers. The power curves indicate pump input power per stage. Curves are shown for pump with one stage (P21), low-NPSH stage (P21n) and reduced-diameter impellers (P22/3). Pump type, frequency and ISO standard. QH curve for the individual pump. The bold curves indicate the recommended duty range for best efficiency. The eta curve shows the efficiency of the pump. The eta curve is an average curve of all the pump types shown in the chart. The efficiency of pumps with reduced-diameter impellers is approx. 2 % lower than the eta curve shown in the chart. The NPSH curve is an average curve for all the variants shown. When sizing the pumps, add a safety margin of at least 0.5 m. QH curve for each individual impeller. Curves for complete (1/1) and reduced-diameter (2/3) impellers are shown.

68

TM01 9129 0303

How to read the curve charts


Guidelines to curve charts
The guidelines below apply to the curves shown on the following pages: Tolerances to ISO 9906, Annex A, if indicated. The motors used for the measurements are standard Grundfos motors (MG or MGE). Measurements have been made with airless water at a temperature of 20 C. The curves apply to a kinematic viscosity of = 1 mm2/s (1 cSt). Due to the risk of overheating, the pumps should not be used at a flow below the minimum flow rate. The QH curves apply to a rated motor speed of 2900 min-1. All curves are based on current motor speeds. The curve below shows the minimum flow rate as a percentage of the nominal flow rate in relation to the liquid temperature. The dotted line shows a CR pump fitted with an air-cooled top assembly.

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Qmin [%]
30 20 10 0 40 60 80 100 120 140 160 180 t
TM01 2816 0303

CR

[C]

Fig. 86 Minimum flow rate

69

Performance curves
CR deep-well
HD [m]
100 CR(I) 5-15 90 80 70 CR(I) 5-11 60 CR(I) 5-9 50 40 30 20 10 0 0.00 0.25 0.50 0.75 1.00 1.25 1.50 CR(I) 5-13 No. 11B No. 29B No. 20B No. 22B No. 44B

CR deep-well pumps 50 and 60 Hz

50 Hz

No. 45B

1.75

Q [m/h] Q [l/s]

0.0

0.1

0.2

0.3

0.4

0.5

For information about dimensions of the individual pumps, see page 111.

CR deep-well
HD [m]
90 80 CR(I) 5-9 70 60 CR(I) 5-6 50 CR(I) 5-8 No. 11B No. 29B No. 20B No. 22B No. 44B No. 45B

60 Hz

Performance curves

40 30 20 10 0 0.00 0.25 0.50 0.75 1.00 1.25 1.50


TM03 3971 1806

Q [m/h] Q [l/s]

0.0

0.1

0.2

0.3

0.4

For information about dimensions of the individual pumps, see page 111.

70

TM03 3096 1806

Performance curves
Low-NPSH pumps
p [kPa] H [m]
240 220 2000 200 180 1600 160 -23 140 1200 -19 120 -17 100 800 80 60 -8 400 40 20 0 0 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 -7 -6 -4 -5 -3 -15 -12 -10 -9 -13 -11 -21 -31 -29 -27 -25 -36

Low-NPSH pumps 50 Hz

CR, CRI, CRN 3


50 Hz
ISO 9906 Annex A -33

Q [m/h] Q [l/s] Eta [%]

0.0

0.2

0.4

0.6

0.8

1.0

1.2

P2 [kW]
0.15 0.10 0.05 0.00 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 P21/1 Eta P21/1n

60 40 20 0

Performance curves

Q [m/h] NPSH [m]

H [m]
QH 2900 rpm1/1n 6 4 2 0 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 QH 2900 rpm1/1 NPSH Low NPSH

3 2 1 0
TMX2 1186 1309

Q [m/h]

For information about dimensions of the individual pumps, see page 117.

71

Performance curves

Low-NPSH pumps 50 Hz

p [kPa]
2400

H [m]
260 -36 240 220 -32 -29 -26 -24 -22 140 -20 -18 -16 100 -15 -14 -13 -12 -11 -10 60 -8 -7 -9 -6 -5 -4 20

CR, CRI, CRN 5


50 Hz
ISO 9906 Annex A

2000

200 180

1600

160

1200

120

800

80

400

40

0 0 1 2 3 4 5 6 7 8 9Q 2.5

[m/h] Q [l/s] Eta [%]

0.0

0.5

1.0

1.5 Eta

2.0

P2 [kW]
0.30 0.20 0.10

P21/1n

60 40

P21/1

20 0

Performance curves

0.00 0 1 2 3 4 5 6 7 8

H [m]
12 8 4 QH 2900 rpm1/1n QH 2900 rpm1/1

9Q

[m/h] NPSH [m]


6 4 2 0
TMX2 1189 1309

NPSH Low NPSH

0 0 1 2 3 4 5 6 7 8 9Q

[m/h]

For information about dimensions of the individual pumps, see page 118.

72

Performance curves

Low-NPSH pumps 50 Hz

p [kPa]

H [m]
240 220 -22 -20 -18

CR, CRI, CRN 10


50 Hz
ISO 9906 Annex A

2000

200 180

1600

160 140

-16 -14 -12

1200

120 100

-10 -9 -8 -7 -6 -5 -4 -3

800

80 60

400

40 20

0 0 1 2 3 4 5 6 7 8 9 10 11 12

Q [m/h]
3.5

0.0

0.5

1.0

1.5

2.0 Eta

2.5

3.0

Q [l/s]
P21/1n

P2 [kW]
0.6 0.4

Eta [%]
60 40

P21/1 0.2 0.0 0 1 2 3 4 5 6 7 8 9 10 11 12 20

Performance curves

Q [m/h] NPSH [m]


6 NPSH 4 2 LOW NPSH 0

H [m]
12 8 4 0 0

QH 2900 rpm1/1n QH 2900 rpm1/1

10

11

12

Q [m/h]

For information about dimensions of the individual pumps, see page 118.

TM02 7391 1309

73

Performance curves

Low-NPSH pumps 50 Hz

p [kPa]

H [m]
240 220

-17

CR, CRI, CRN 15


50 Hz
ISO 9906 Annex A

2000

200 180

-14

-12

1600

160 -10 140 -9

1200

120 100

-8 -7 -6

800

80 60

-5 -4 -3

400

40 20

-2

0 0 2 4 6 8 10 12 14 16 18 20 22

Q [m/h] Q [l/s] Eta [%]


80 P21/1n P21/1 60 40 20 0

P2 [kW]
2.0 1.5 1.0 0.5 Eta

Performance curves

0.0 0 2 4 6 8 10 12 14 16 18 20 22

Q [m/h]
NPSH

H [m]
20 15 10 5 0 0

QH 2900 rpm1/1n QH 2900 rpm1/1

NPSH [m]
4 3 2

LOW NPSH

1 0

10

12

14

16

18

20

22

Q [m/h]

For information about dimensions of the individual pumps, see page 119.

74

TM02 7392 1309

Performance curves

Low-NPSH pumps 50 Hz

p [kPa]
2400

H [m]
260 240 220 -14 -17

CR, CRI, CRN 20


50 Hz
ISO 9906 Annex A

2000

200 180 -12

1600

160 -10 140

1200

120 100

-8 -7 -6 -5 -4 -3

800

80 60

400

40 20

-2

0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28

Q [m/h]
8

Q [l/s] Eta [%]


80 P21/1n P21/1 60 40 20

P2 [kW]
2.0 1.5 1.0 0.5 0.0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 Eta

Performance curves

Q [m/h] NPSH [m]


8 NPSH 6 4

H [m]
20 15 10 5 0 0

QH 2900 rpm1/1n QH 2900 rpm1/1

LOW NPSH 2 4 6 8 10 12 14 16 18 20 22 24 26 28

2 0

Q [m/h]

For information about dimensions of the individual pumps, see page 119.

TM02 7393 1309

75

Performance curves

Low-NPSH pumps 50 Hz

p [kPa]

H [m]
280 260 -14 -13 -12 -11 -10 -9 -8 -8-2 140 -7 -7-2 -6 -6-2 100 -5 -5-2 -4 -4-2 60 -3 -3-2 -2 -14-2 -13-2 -12-2 -11-2 -10-2 -9-2

CR, CRN 32
50 Hz
ISO 9906 Annex A

2400

240 220

2000

200 180

1600

160

1200

120

800

80

400

40 20

0 0 4 8 12 16 20 24 28 32 36

Q [m/h] Q [l/s]
P21/1n

10

P2 [kW]
2.8 2.1 1.4 0.7 Eta

Eta [%]
80 60

P21/1 P22/3

40 20 0

Performance curves

0.0 0 4 8 12 16 20 24 28 32 36

p H [kPa] [m]
240 160 80 0 24 16

Q [m/h]
NPSH

QH 2900 rpm1/1n QH 2900 rpm1/1

NPSH [m]
6 4

QH 2900 rpm2/3 Low NPSH 0 0 4 8 12 16 20 24 28 32 36 0


TM01 9129 1309

Q [m/h]

For information about dimensions of the individual pumps, see page 120.

76

Performance curves

Low-NPSH pumps 50 Hz

p [kPa]
3200

H [m]
340 -13-2 320 -12 300 -12-2 -11-2

CR, CRN 45
50 Hz
ISO 9906 Annex A

2800

280 260

-11 -10

2400

-10-2 240 -9 220 -9-2 -8 -8-2 -7 -7-2 -6 -6-2 -5 120 100 -4 -4-2 -3 -3-2 60 -2 -5-2

2000

200 180

1600

160 140

1200

800

80

400

40 20

0 0 5 10 15 20 25 30 35 40 45 50 55

Q [m/h]
16

10

12

14

P2 [kW]
8 6 4 2 0

Q [l/s]

Eta

Eta [%]
80 60

P21/1n P21/1 P22/3

40 20

Performance curves

0 0 5 10 15 20 25 30 35 40 45 50 55

p H [kPa] [m]
240 160 80 0 24 16 8 0

Q [m/h]

QH 2900 rpm1/1n QH 2900 rpm1/1 QH 2900 rpm2/3 NPSH

NPSH [m]
6 4
TMX1 1451 1309

Low NPSH 2 0 0 5 10 15 20 25 30 35 40 45 50 55

Q [m/h]

For information about dimensions of the individual pumps, see page 121.

77

Performance curves

Low-NPSH pumps 50 Hz

p [kPa]
2000

H [m]
200 -7-1 -7-2 180 -6 -6-1

CR, CRN 64
50 Hz
ISO 9906 Annex A

1600

160 -5 140 -5-1

-6-2

-5-2 1200 120 -4 -4-1 100 -3 800 80 -3-1 -3-2 60 -2 -2-1 400 40 -4-2

20

0 0 10 20 30 40 50 60 70 80

Q [m/h]
25

10

15

20

P2 [kW]
8 6 4 2 Eta P21/1n P21/1 P22/3

Q [l/s]

Eta [%]
80 60 40 20 0

Performance curves

0 0 10 QH 2900 rpm1/1n QH 2900 rpm1/1 QH 2900 rpm2/3 Low NPSH 0 10 20 30 40 50 60 70 80 NPSH 20 30 40 50 60 70 80

p H [kPa] [m]
300 200 16 100 0 8 0 32 24

Q [m/h]

NPSH [m]
8 6 4 2 0
TM02 0753 1309

Q [m/h]

For information about dimensions of the individual pumps, see page 121.

78

Performance curves
Low-NPSH pumps
p [Mpa] H [m]
240 220 2.0 200 180 1.6 160 140 1.2 120 100 0.8 80 -7 60 -5 0.4 40 -3 20 0.0 0 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 4.8 5.2 -4 -6 -13 -12 -11 -10 -9 -8 -17 -15 -21 -25

Low-NPSH pumps 60 Hz

CR, CRI, CRN 3


60 Hz
ISO 9906 Annex A -23

-19

Q [m/h] Q [l/s]

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

P2 [kW]
0.24 0.16 0.08 0.00 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 4.8 5.2

Eta [%]
60

P21/1n Eta P21/1

40 20 0

Performance curves

p H [kPa] [m]
80 60 40 20 0 9 6 3

Q [m/h]

QH 3500 rpm1/1n QH 3500 rpm1/1 NPSH

NPSH [m]
6 4
TM02 2574 1309

2 Low NPSH 0 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 4.8 5.2

Q [m/h]

For information about dimensions of the individual pumps, see page 122.

79

Performance curves

Low-NPSH pumps 60 Hz

p [kPa]

H [m]
240 220 -24

CR, CRI, CRN 5


60 Hz
ISO 9906 Annex A -22 -20

2000

200 180

-18 -16 -15 -14 -13 -12 -11 -10 -9 -8 -7 -6 -5 -4

1600

160 140

1200

120 100

800

80 60

400

40 20

0 0 1 2 3 4 5 6 7 8 9 10

Q [m/h]
3.0

0.0

0.5

1.0

1.5

2.0

2.5

P2 [kW]
1.2 0.8 0.4 Eta P21/1n

Q [l/s]

Eta [%]
60 40 20

Performance curves

P21/1 0.0 0 1 2 3 4 5 6 7 8 9 10 0

p [kPa]
150 100 50 0

H [m]
15 10 5 0 0 1 2 3 4 5 6 7 8 9 10 QH 3500 rpm1/1n QH 3500 rpm1/1

Q [m/h]

NPSH [m]
6

NPSH 4
TM02 2575 1309

Low NPSH

2 0

Q [m/h]

For information about dimensions of the individual pumps, see page 122.

80

Performance curves

Low-NPSH pumps 60 Hz

p [kPa]
2400

H [m]
260 -17 240 -16 220

CR, CRI, CRN 10


60 Hz
ISO 9906 Annex A

2000

200 180

-14

-12 1600 160 140 1200 120 -8 100 800 80 60 400 40 20 0 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 -7 -6 -5 -4 -3 -10 -9

Q [m/h] Q [l/s] Eta [%]


80

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

P2 [kW]
1.6 1.2 0.8 0.4 0.0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 P21/1 Eta P21/1n

60 40 20

Performance curves

Q [m/h] NPSH [m]


8 6 4

H [m]
20 15 10 5 0 0

QH 3500 rpm1/1n QH 3500 rpm1/1 NPSH LOW NPSH

2 0

10

11

12

13

14

15

16

Q [m/h]

For information about dimensions of the individual pumps, see page 122.

TM02 7394 1309

81

Performance curves

Low-NPSH pumps 60 Hz

p [kPa]
2400

H [m]
260 -12 240 220 -10

CR, CRI, CRN 15


60 Hz
ISO 9906 Annex A

2000

200 -9 180 -8

1600

160 -7 140 -6

1200

120 -5 100 -4

800

80 -3 60 -2

400

40 20

0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28

Q [m/h]
8

Q [l/s] Eta [%]


80

P2 [kW]
3.2 2.4 1.6 0.8 Eta P21/1n P21/1

60 40 20 0

Performance curves

0.0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28

Q [m/h] NPSH [m]


8 6 NPSH 4

H [m]
20 15 10 5 0 0

QH 3500 rpm1/1n QH 3500 rpm1/1

LOW NPSH 2 4 6 8 10 12 14 16 18 20 22 24 26 28

2 0

Q [m/h]

For information about dimensions of the individual pumps, see page 123.

82

TM02 7395 1309

Performance curves

Low-NPSH pumps 60 Hz

p [kPa]
2000

H [m]
200

CR, CRI, CRN 20


60 Hz
ISO 9906 Annex A -8

180 1600

160

-7

140

-6

1200

120 -5 100 -4

800

80 -3 60 -2

400

40

20

0 0 4 8 12 16 20 24 28 32

Q [m/h]
10

Q [l/s] Eta [%]


80

P2 [kW]
3.2 2.4 1.6 0.8 0.0 0 4 8 12 16 20 24 28 32 Eta P21/1n P21/1

60 40 20

Performance curves

Q [m/h]
NPSH

H [m]
32 24 16 8 0 0 4 8 12 16 20 24 28 32 QH 3500 rpm1/1n QH 3500 rpm1/1

NPSH [m]
8 6

LOW NPSH

4 2 0
TM02 7396 1309

Q [m/h]

For information about dimensions of the individual pumps, see page 123.

83

Performance curves

Low-NPSH pumps 60 Hz

p [kPa]

H [m]
280 260 -10-2 -9 -9-2 240 -8 220 -8-2 -7 -7-2 180 -6

CR, CRN 32
60 Hz
ISO 9906 Annex A

2400

2000

200

1600

160 140 -5

-6-2

-5-2 1200 120 100 800 80 60 400 40 20 0 0 0 4 8 12 16 20 24 28 32 36 40 44 -3 -3-2 -2 -2-1 -4 -4-2

Q [m/h] Q [l/s] Eta [%]


80 P21/1n P21/1 P22/3 60 40 20 0

10

12

P2 [kW]
8 6 4 2

Eta

Performance curves

0 0 4 8 12 16 20 24 28 32 36 40 44

Q [m/h]
NPSH

p H [kPa] [m]
40 320 240 160 80 0 20 10 0 0 4 8 12 16 20 24 28 32 36 40 44 QH 3500 rpm2/3 Low NPSH 30 QH 3500 rpm1/1n QH 3500 rpm1/1

NPSH [m]
8 6 4 2 0
TM02 2578 1309

Q [m/h]

For information about dimensions of the individual pumps, see page 124.

84

Performance curves

Low-NPSH pumps 60 Hz

p [kPa]
2400

H [m]
260 240 220 -6 -7 -7-1 -7-2

CR, CRN 45
60 Hz
ISO 9906 Annex A

-6-1 -6-2

2000

200 180 -5 -5-1 -5-2

1600

160 -4 140 -4-1 -4-2

1200

120 -3 100 -3-1 -3-2

800

80 60

-2 -2-1

400

40 20

0 0 5 10 15 20 25 30 35 40 45 50 55 60 65

Q [m/h] Q [l/s]
P21/1n Eta P21/1 P22/3

10

12

14

16

18

P2 [kW]
8 6 4 2 0 0 5 10 15 20 25 30 35 40 45 50 55 60 65

Eta [%]
80 60 40 20

Performance curves

p H [kPa] [m]
400 300 200 100 0 40 30 20 10 0 0

Q [m/h]

QH 3500 rpm1/1n QH 3500 rpm1/1 QH 3500 rpm2/3 NPSH

NPSH [m]
8 6 4

Low NPSH 5 10 15 20 25 30 35 40 45 50 55 60 65

2 0

Q [m/h]

For information about dimensions of the individual pumps, see page 124.

TM02 2579 1309

85

Performance curves

Low-NPSH pumps 60 Hz

p [kPa]

H [m]
180 -5-2 -4

CR, CRN 64
60 Hz
ISO 9906 Annex A

1600

160

-4-1 -4-2 -3

140

1200

120

-3-1 -3-2 -2

100

800

80 -2-1 60

400

40

20

0 0 10 20 30 40 50 60 70 80 90

Q [m/h] Q [l/s]

10

15

20

25

P2 [kW]
16 12 8 4

Eta [%]
80 60 40 20 0

Eta P21/1n P21/1 P22/3

Performance curves

p H [kPa] [m]
50 400 300 200 100 0 40 30 20 10 0

10

20

30

40

50

60

70

80

90

Q [m/h]

NPSH [m]
10 8 6

QH 3500 rpm1/1n NPSH QH 3500 rpm1/1 QH 3500 rpm2/3 Low NPSH 0 10 20 30 40 50 60 70 80 90

4 2 0
TM02 2580 1309

Q [m/h]

For information about dimensions of the individual pumps, see page 125.

86

Performance curves
CR pumps with 4-pole motor
p [kPa] H [m]
55 500 -33 -36

CR pumps with 4-pole motor 50 Hz

CR, CRI, CRN 1


50 Hz
ISO 9906 Annex A

50

45 400 -27

-30

40

-25 35 300 -23 -21 30 -19 -17 -15 200 20 -12 -11 15 -10 -9 -8 100 10 -7 -6 -5 5 -4 -3 -2 0 0 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 -13

25

Q [m/h] Q [l/s] Eta [%]


Eta P2 40

0.00

0.05

0.10

0.15

0.20

0.25

0.30

P2 [hp]
0.015 0.010

P2 [kW]
0.010

0.005 0.005 0.000 0.000 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1

20

Performance curves

Q [m/h] NPSH [m]


1.0

p [kPa]
20

H [m]
2 QH 1450 rpm

10

1 NPSH

0.5
TM02 2543 1309

0 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1

0.0

Q [m/h]

For information about dimensions of the individual pumps, see page 126.

87

Performance curves

CR pumps with 4-pole motor 50 Hz

p [kPa]

H [m]
60 55 -36

CR, CRI, CRN 3


50 Hz
ISO 9906 Annex A -33 -31

500

50 -29 45 -27 -25 -23 35 -21 -19 30 -17 25 -15 -12 -10 -8 -9 -7 -5 -4 5 -2 -3 -13 -11 15

400

40

300

200

20

100

10

-6

0 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0

Q [m/h]
0.6

0.0

0.1

0.2

0.3

0.4

0.5

Q [l/s] Eta [%]


60 Eta P2 40 20 0

P2 [hp]
0.020 0.015 0.010 0.005

P2 [kW]
0.015 0.010 0.005 0.000 0.0 0.2 QH 1450 rpm 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0

Performance curves

0.000

Q [m/h] NPSH [m]


1.5 1.0

p [kPa]
15 10 5 0

H [m]
1.5 1.0 0.5 0.0 0.0

0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0

Q [m/h]

For information about dimensions of the individual pumps, see page 127.

88

TM02 2542 1309

NPSH

0.5

Performance curves

CR pumps with 4-pole motor 50 Hz

p [kPa]
600

H [m]
65 -36 60 55

CR, CRI, CRN 5


50 Hz
ISO 9906 Annex A

-32 -29

500

50 45

-26 -24 -22

400

40 35

-20 -18 -16 -15 -13 -11 -10 -9 -8 -7 -6 -5 -4 -3 -2

300

30 25

-14 -12

200

20 15

100

10 5

0 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0

Q [m/h]
1.2

0.0

0.2

0.4

0.6

0.8

1.0

Q [l/s] Eta [%]


60 40 20

P2 [hp]
0.020 0.015 0.010 0.005 0.000

P2 [kW]
0.015 0.010 0.005 0.000 0.0 0.4 QH 1450 rpm 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0

P2 Eta

Performance curves

Q [m/h] NPSH [m]


1.5 1.0
TM02 2541 1309

p [kPa]
15 10 5 0

H [m]
1.5 1.0 0.5

0.5 NPSH 0.0 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0

0.0

Q [m/h]

For information about dimensions of the individual pumps, see page 127.

89

Performance curves

CR pumps with 4-pole motor 50 Hz

p [kPa]

H [m]
60 -22 55 -20 50 45 -18 -16 -14 -12 -10 -9 -8 -7 -6 -5 -4 -3 -2 -1

CR, CRI, CRN 10


50 Hz
ISO 9906 Annex A

500

400

40 35

300

30 25

200

20 15

100

10 5

0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0

Q [m/h] Q [l/s] Eta [%]


Eta P2 60 40 20 0

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

P2 [hp]
0.08 0.06 0.04 0.02

P2 [kW]
0.06 0.04 0.02 0.00 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0

Performance curves

0.00

Q [m/h] NPSH [m]


1.5 1.0
TM02 7273 1309

p [kPa]
20

H [m]
2.4 1.6

QH 1450 rpm

10 0

0.8 NPSH 0.0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0

0.5 0.0

Q [m/h]

For information about dimensions of the individual pumps, see page 128.

90

Performance curves

CR pumps with 4-pole motor 50 Hz

p [kPa]

H [m]
60 55 -17

CR, CRI, CRN 15


50 Hz
ISO 9906 Annex A

500

50 45

-14

-12 400 40 35 300 30 25 200 20 -5 15 100 10 -2 5 0 0 0 1 2 3 4 5 6 7 8 9 10 11 -1 -4 -3 -10 -9 -8 -7 -6

Q [m/h] Q [l/s]
Eta P2

0.0

0.5

1.0

1.5

2.0

2.5

3.0

P2 [hp]
0.16 0.12 0.08 0.04 0.00

P2 [kW]
0.12 0.08 0.04 0.00 0 1 QH 1450 rpm 2 3 4 5 6 7 8 9 10 11

Eta [%]
60 40 20

Performance curves

Q [m/h] NPSH [m]


1.5 1.0
TM02 7274 1309

p [kPa]
30 20 10 0

H [m]
3 2 1

0.5 NPSH 0.0 0 1 2 3 4 5 6 7 8 9 10 11

Q [m/h]

For information about dimensions of the individual pumps, see page 129.

91

Performance curves

CR pumps with 4-pole motor 50 Hz

p [kPa]
600

H [m]
65 -17 60 55

CR, CRI, CRN 20


50 Hz
ISO 9906 Annex A

500

-14 50 45 -12

400

40 -10 35

300

30 25

-8 -7 -6

200

20 15

-5 -4 -3

100

10 -2 5 -1

0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14

Q [m/h] Q [l/s] Eta [%]


Eta P2 60 40 20 0

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

P2 [hp]
0.20 0.15 0.10 0.05

P2 [kW]
0.15 0.10 0.05 0.00 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14

Performance curves

0.00

Q [m/h] NPSH [m]


1.5 1.0 0.5

p [kPa]
30 20 10 0

H [m]
3 2 1

QH 1450 rpm

NPSH 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 0.0

Q [m/h]

For information about dimensions of the individual pumps, see page 129.

92

TM02 7275 1309

Performance curves

CR pumps with 4-pole motor 50 Hz

p [kPa]

H [m]
70 65 14 14-2 13 13-2 12 12-2 55 11 11-2 50 45 10 10-2 9 9-2 8 8-2 35 7 7-2 6 6-2 25 5 5-2 4 4-2 15 3 3-2 2 2-2 5 1 1-1

CR, CRN 32
50 Hz
ISO 9906 Annex A

600

60

500

400

40

300

30

200

20

100

10

0 0 2 4 6 8 10 12 14 16 18

Q [m/h] Q [l/s] Eta [%]


80 60 P21/1n P22/3 40 20

P2 [hp]
0.5 0.4 0.3 0.2 0.1 0.0

P2 [kW]
0.4 0.3 0.2 0.1 0.0 0 2 4 6 8 10 12

Eta

Performance curves

0 14 16 18

p [kPa]
40 30 20 10 0

H [m]
5 4 3 2 1 0 0

Q [m/h]

QH 1450 rpm1/1n QH 1450 rpm2/3 NPSH

NPSH [m]
2.5 2.0 1.5 1.0 0.5 0.0
TM01 8153 1309

10

12

14

16

18

Q [m/h]

For information about dimensions of the individual pumps, see page 130.

93

Performance curves

CR pumps with 4-pole motor 50 Hz

p [kPa]
800

H [m]
85 80 75 12 12-2 11 70 65 10 10-2 60 55 9 9-2 8 50 45 7 7-2 6 6 -2 5 5-2 4 4-2 3 3-2 2 2-2 1 5 1-1 8-2 11-2 13-2

CR, CRN 45
50 Hz
ISO 9906 Annex A

700

600

500

400

40 35

300

30 25

200

20 15

100

10

0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28

Q [m/h]
8

P2 P2 [hp] [kW]
0.4 0.4 0.2 0.1 0.3 0.2

Q [l/s]
P21/1n P22/3

Eta

Eta [%]
80 60 40 20 0

Performance curves

0.0

0.0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28

Q [m/h] NPSH [m]


1.5 1.0

p H [kPa] [m]
60 40 20 0 6 4 2 0 0

QH 1450 rpm1/1n QH 1450 rpm2/3 NPSH

0.0 2 4 6 8 10 12 14 16 18 20 22 24 26 28

Q [m/h]

For information about dimensions of the individual pumps, see page 131.

94

TM01 8154 1309

0.5

Performance curves

CR pumps with 4-pole motor 50 Hz

p [kPa]

H [m]
55 7

8-1 8-2

CR, CRN 64
50 Hz
ISO 9906 Annex A

500

50 6

7-1 7-2

45 400

6-1 40 5 35 300 4 4-1 25 3 200 20 2 2-1 100 10 2-2 1 1-1 5 3-1 3-2 15 4-2 5-1 5-2 30 6-2

0 0 5 10 15 20 25 30 35 40

Q [m/h] Q [l/s]

8 Eta P21/1n P22/3

10

P2 [hp]
1.0 0.8 0.6 0.4 0.2 0.0

P2 [kW]
0.8 0.6 0.4 0.2 0.0 0 5 QH 1450 rpm1/1n QH 1450 rpm2/3 10 15 20 25 30

Eta [%]
80 60 40 20 0

Performance curves

35

40

p H [kPa] [m]
60 40 20 0 6 4

Q [m/h]

NPSH [m]
1.2 0.8

NPSH 2 0 0 5 10 15 20 25 30 35 40 0.4 0.0


TM01 8155 1309

Q [m/h]

For information about dimensions of the individual pumps, see page 132.

95

Performance curves

CR pumps with 4-pole motor 50 Hz

p [kPa]
500

H [m]
50

CR, CRN 90
50 Hz
ISO 9906 Annex A 6-2

45 5 400 40

5-2 35 4

300

30 3 25

4-2

200

20 2 15

3-2

2-2 100 10 1 1-1 5

0 0 5 10 15 20 25 30 35 40 45 50 55

Q [m/h]
16

10

12 Eta

14

P2 [hp]
1.0 0.5

P2 [kW]
1.00 0.75

Q [l/s]

Eta [%]
80 60

P21/1n P22/3 0.50 40 20 0 0 5 10 15 20 25 30 35 40 45 50 55 0.25 0.0 0.00

Performance curves

p H [kPa] [m]
80 60 40 20 0 8 6 4 2 0 0

Q [m/h]

QH 1450 rpm1/1n QH 1450 rpm2/3

NPSH [m] NPSH


1.6 1.2 0.8 0.4 0.0
TM01 8156 1309

10

15

20

25

30

35

40

45

50

55

Q [m/h]

For information about dimensions of the individual pumps, see page 132.

96

Performance curves

CR pumps with 4-pole motor 50 Hz

p [kPa]
500

H [m]
7 50

CR, CRN 120


50 Hz
ISO 9906 Annex A

45 6-1 400 40

35

5-1

300

30 4-1 25 3

200

20

15

2 2-1

100

10 1 5

0 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75

Q [m/h] Q [l/s]

10

12

14

16

18

20

P2 [hp]
2.0 1.5 1.0 0.5 0.0

P2 [kW]
1.6 1.2 0.8 0.4 0.0 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 Eta P21/1n P22/3

Eta [%]
80 60 40 20

Performance curves

p [kPa]
80 60 40 20 0

H [m]
8 6 4 2 0 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 NPSH QH 1450 rpm1/1n QH 1450 rpm2/3

Q [m/h]

NPSH [m]
2.0 1.5 1.0
TM03 9077 1309

0.5 0.0

Q [m/h]

For information about dimensions of the individual pumps, see page 133.

97

Performance curves

CR pumps with 4-pole motor 50 Hz

p [kPa]
500

H [m]
50 6 45

CR, CRN 150


50 Hz
ISO 9906 Annex A

400

40

35

5-2

300

30

4-1

25

200

20

3-2

15

2-1

100

10 1 1-1 5

0 0 10 20 30 40 50 60 70 80 90

Q [m/h]
26 28 Q

10

12

14

16

18

20

22

24

P2 [hp]
2.0 1.5 1.0 0.5

P2 [kW]
1.6 1.2 0.8 0.4 0.0 0 10 20 30 40 50 60 70 80 90 Eta

[l/s]

Eta [%]
80 60 40 20 0

P21/1n P22/3

Performance curves

0.0

p [kPa]
80 60 40 20 0

H [m]
8 6 4 2 0 0 10 20 30 40 50 60 70 80 90 NPSH QH 1450 rpm1/1n QH 1450 rpm2/3

Q [m/h]

NPSH [m]
4 3 2
TM03 9078 1309

1 0

Q [m/h]

For information about dimensions of the individual pumps, see page 133.

98

Performance curves
CR pumps with 4-pole motor
p [kPa] H [m]
60 55 500 50 45 -19 400 40 -17 35 -15 300 30 -13 25 200 20 -8 15 -6 100 10 5 0 0 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 -5 -4 -3 -2 -7 -12 -11 -10 -9 -23 -21 -27 -25

CR pumps with 4-pole motor 60 Hz

CR, CRI, CRN 1


60 Hz
ISO 9906 Annex A

1.3

1.4

Q [m/h] Q [l/s]

0.00

0.05

0.10

0.15

0.20

0.25

0.30

0.35

0.40

P2 [hp]
0.020 0.015 0.010 0.005 0.000

P2 [kW]
0.015 0.010 0.005 0.000 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.4

Eta [%]
60

P2 Eta

40

Performance curves

20 0

p [kPa]
30 20 10 0

H [m]
3 QH 1750 rpm 2 1 NPSH 0 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.4

Q [m/h]

NPSH [m]
1.5 1.0
TM02 2540 1309

0.5 0.0

Q [m/h]

For information about dimensions of the individual pumps, see page 134.

99

Performance curves

CR pumps with 4-pole motor 60 Hz

p [kPa]

H [m]
60 55 -25

CR, CRI, CRN 3


60 Hz
ISO 9906 Annex A -23

500

50 45

-21 -19 -17 -15 -13 -12 -11 -10 -9 -8 -7 -6 -5 -4 -3 -2

400

40 35

300

30 25

200

20 15

100

10 5

0 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6

Q [m/h] Q [l/s]

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

P2 [hp]
0.04 0.03 0.02 0.01

P2 [kW]
0.03 0.02 0.01 0.00 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6

Eta [%]
60

Eta P2

40 20 0

Performance curves

0.00

p H [kPa] [m]
30 20 10 0 3 QH 1750 rpm 2 1 0 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 NPSH

Q [m/h]

NPSH [m]
1.5 1.0 0.5 0.0
TM02 2539 1309

Q [m/h]

For information about dimensions of the individual pumps, see page 134.

100

Performance curves

CR pumps with 4-pole motor 60 Hz

p [kPa]

H [m]
60 55 -24

CR, CRI, CRN 5


60 Hz
ISO 9906 Annex A -22 -20 -18 -16 -15 -14 -13 -12 -11 -10 -9 -8 -7 -6 -5 -4 -3 -2

500

50 45

400

40 35

300

30 25

200

20 15

100

10 5

0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0

Q [m/h] Q [l/s] Eta [%]


P2 Eta 60 40 20 0

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

P2 [hp]
0.04 0.03 0.02 0.01 0.00

P2 [kW]
0.03 0.02 0.01 0.00 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0

Performance curves

Q [m/h] NPSH [m]


1.5

p [kPa]
30 20 10 0

H [m]
3 QH 1750 rpm 2 1 NPSH 0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0

1.0 0.5 0.0


TM02 2538 1309

Q [m/h]

For information about dimensions of the individual pumps, see page 135.

101

Performance curves

CR pumps with 4-pole motor 60 Hz

p [kPa]
600

H [m]
65 60 55

-17

CR, CRI, CRN 10


60 Hz
ISO 9906 Annex A

-16

-14 500 50 45 400 40 -10 35 300 30 25 -6 200 20 15 100 10 5 0 0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 -5 -4 -3 -2 -1 -9 -8 -7 -12

Q [m/h] Q [l/s]
P2 Eta

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

2.0

P2 [hp]
0.08 0.06 0.04 0.02

P2 [kW]
0.06 0.04 0.02 0.00 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5

Eta [%]
60 40 20 0

Performance curves

0.00

Q [m/h] NPSH [m]


1.5 1.0 0.5

p [kPa]
30 20 10 0

H [m]
3.0 2.0 1.0

QH 1750 rpm

NPSH 0.0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 0.0

Q [m/h]

For information about dimensions of the individual pumps, see page 135.

102

TM02 7276 1309

Performance curves

CR pumps with 4-pole motor 60 Hz

p [kPa]

H [m]
60 55

-12

CR, CRI, CRN 15


60 Hz
ISO 9906 Annex A

500

50 45

-10 -9

400

40 35

-8 -7 -6 -5

300

30 25

200

20 15

-4 -3 -2 -1

100

10 5

0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14

Q [m/h] Q [l/s] Eta [%]


60 40 20

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5 Eta P2

4.0

P2 [hp]
0.20 0.15 0.10 0.05 0.00

P2 [kW]
0.15 0.10 0.05 0.00 0 1 2 3 4 5 6 7 8 9 10 11 12 13

Performance curves

0 14

Q [m/h] NPSH [m]


1.5

p [kPa]
60 40 20 0

H [m]
6 QH 1750 rpm 4 2 NPSH 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14

1.0
TM02 7277 1309

0.5 0.0

Q [m/h]

For information about dimensions of the individual pumps, see page 136.

103

Performance curves

CR pumps with 4-pole motor 60 Hz

p [kPa]

H [m]
55 -10

CR, CRI, CRN 20


60 Hz
ISO 9906 Annex A

500

50

45 -8 400 40 -7 35 -6 300 30 -5 25 -4 200 20 -3 15 -2 10 -1

100

0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Q [m/h] Q [l/s] Eta [%]


Eta P2 60 40 20 0

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

P2 [hp]
0.3 0.2 0.1

P2 [kW]
0.24 0.16 0.08 0.00 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Performance curves

0.0

Q [m/h] NPSH [m]

p [kPa]
60 40 20 0

H [m]
6 4 2 NPSH 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 QH 1750 rpm

3 2
TM02 7278 1309

1 0

Q [m/h]

For information about dimensions of the individual pumps, see page 136.

104

Performance curves

CR pumps with 4-pole motor 60 Hz

p [kPa]

H [m]
70 10-2 65 -9 9-2 -8 55 8-2 -7 7-2 45 -6 6-2 -5 35 5-2

CR, CRN 32
60 Hz
ISO 9906 Annex A

600

60

500

50

400

40

300

30 25

-4 4-2 -3 -

200

20 15 -2

3-2

100

10 5

2-1 2-2 -1 1-1

0 0 2 4 6 8 10 12 14 16 18 20 22

Q [m/h] Q [l/s]

P2 P2 0 [hp] [kW]
0.6 0.4 0.2 0.1 0.0 0.0 0.4 0.3 0.2

Eta [%]
80 60 40 20

Eta

P21/1 P22/3

Performance curves

0 0 2 4 6 8 10 12 14 16 18 20 22

p [kPa]
80 60 40 20 0

H [m]
8 6 4 2 0

Q [m/h]

NPSH [m]
4 3

QH 1750 rpm1/1 QH 1750 rpm2/3 NPSH

2 1 0
TM01 8157 1309

10

12

14

16

18

20

22

Q [m/h]

For information about dimensions of the individual pumps, see page 137.

105

Performance curves

CR pumps with 4-pole motor 60 Hz

p [kPa]
600

H [m]
65 60

7 7-1 7-2

CR, CRN 45
60 Hz
ISO 9906 Annex A

6 55 500 50 5 45 400 40 4 35 300 30 25 200 20 15 100 10 5 0 0 0 4 8 12 16 20 24 28 32 1 1-1 2 2-1 2-2 4-1 4-2 3 3-1 3-2 5-1 5-2 6-1 6-2

Q [m/h]
10

P2 P2 [hp] [kW]
1.0 0.8 0.6 0.4 0.2 0.2 0.0 0.8 0.6 0.4

Q [l/s]

Eta P21/1 P22/3

Eta [%]
80 60 40 20 0

Performance curves

0.0

p [kPa]
80 60 40 20 0

H [m]
8 6 4 2 0

8
QH 1750 rpm1/1

12

16

20

24

28

32

Q [m/h]

NPSH [m]
2.0 1.5 1.0
TM01 8158 1309

QH 1750 rpm2/3

NPSH

0.5 0.0

12

16

20

24

28

32

Q [m/h]

For information about dimensions of the individual pumps, see page 137.

106

Performance curves

CR pumps with 4-pole motor 60 Hz

p [kPa]

H [m]
45 4

5-2

CR, CRN 64
60 Hz
ISO 9906 Annex A

400

40

4-1 4-2

35 3 300 30 3-1 3-2 2 200 20 2-1 15 1 100 10 1-1 5 2-2

25

0 0 5 10 15 20 25 30 35 40 45

Q [m/h]
14 Q

10

12

[l/s] Eta [%]


80

P2 [hp]
1.6 0.8

P2 [kW]
1.6 1.2 0.8 0.4

Eta P21/1 P22/3

60 40 20

Performance curves

0.0

0.0

0 0 5 QH 1750 rpm1/1 QH 1750 rpm2/3 10 15 20 25 30 35 40 45

p [kPa]
80 60 40 20 0

H [m]
10 8 6 4 2 0

Q [m/h]
NPSH

NPSH [m]
2.0 1.6 1.2 0.8 0.4 0.0
TM01 8159 1309

10

15

20

25

30

35

40

45

Q [m/h]

For information about dimensions of the individual pumps, see page 138.

107

Performance curves

CR pumps with 4-pole motor 60 Hz

p [kPa]
400

H [m]
40 3 35 3-1 4-2

CR, CRN 90
60 Hz
ISO 9906 Annex A

300

30 3-2 25 2

200

20

2-1 2-2

15 1 100 10

1-1

0 0 10 20 30 40 50 60 70

Q [m/h]
20

12 Eta

16

Q [l/s] Eta [%]


80

P2 [hp]
2 1

P2 [kW]
2.0 1.5 1.0 0.5

P21/1 P22/3

60 40 20 0

Performance curves

0.0 0 10 20 30 40 50 60 70

Q [m/h] NPSH [m]

p [kPa]
120 80 40 0

H [m]
12 8 4 0 0 10 20 30 40 50 60 70 QH 1750 rpm1/1 NPSH QH 1750 rpm2/3

3 2 1 0
TM01 8160 1309

Q [m/h]

For information about dimensions of the individual pumps, see page 138.

108

Performance curves

CR pumps with 4-pole motor 60 Hz

p [kPa]
500

H [m]
50 5-2 45

CR, CRN 120


60 Hz
ISO 9906 Annex A

400

40

4-1

35 3 300 30 3-1

25 2 200 20 2-1 2-2 1 100 10

15

0 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75

Q [m/h] Q [l/s]

10

12

14

16

18

20

P2 [hp]
2.5 2.0 1.5 1.0 0.5 0.0

P2 [kW]
2.0 1.5 1.0 0.5 0.0 Eta 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 P21/1 P22/3

Eta [%]
80 60 40 20 0

Performance curves

p [kPa]
100 80 60 40 20 0

H [m]
10 8 6 4 2 0

Q [m/h]

QH 1750 rpm1/1 QH 1750 rpm2/3

NPSH [m]
2.5 2.0 1.5

NPSH

1.0
TM03 9079 1309

0.5 0.0

10

15

20

25

30

35

40

45

50

55

60

65

70

75

Q [m/h]

For information about dimensions of the individual pumps, see page 138.

109

Performance curves

CR pumps with 4-pole motor 60 Hz

p [kPa]
400

H [m]
40 4-2

CR, CRN 150


60 Hz
ISO 9906 Annex A

35

300

30 3-2 25 2

200

20

2-1 2-2

15 1 100 10 1-1

0 0 10 20 30 40 50 60 70 80 90

Q [m/h]
26 28 Q

10

12

14

16

18

20

22

24

P2 [hp]
4 3 2 1

P2 [kW]
3.2 2.4 1.6 0.8 0.0

[l/s]

Eta [%]
80 60 40 20 0

Eta P21/1 P22/3

Performance curves

p [kPa]
100 80 60 40 20 0

H [m]
12 10 8 6 4 2 0

10

20

30

40

50

60

70

80

90

Q [m/h] NPSH [m]


3.0 2.5 2.0 1.5 0.5 0.0
TM03 9080 1309

QH 1750 rpm1/1 QH 1750 rpm2/3

NPSH

1.0

10

20

30

40

50

60

70

80

90

Q [m/h]

For information about dimensions of the individual pumps, see page 139.

110

Technical data
CR deep-well pumps
Dimensional drawing

CR deep-well pumps CR low-NPSH pumps CR pumps with 4-pole motor 50 and 60 Hz

Air vent screw G 1/8"

CR 5

Priming plug G 1 1/2"

TM03 8261 0907

111

Technical data

Technical data
CR deep-well pumps, 50 Hz
Dimensions and weights
Pump CR(I) 5-9 Motor P2 [kW] 1.5 Dimensions [mm] B1 465 B1+B2 746 C1 85 D1 178 D2 110

CR deep-well pumps 50 and 60 Hz

Pipe dimensions [mm] Largest Flow Pressure class, Suction Ejecejector plastic pipe depth, HD rate Ejector inlet: Ejector outlet: diameter tor No [m] [m3/h] [kp/cm2] External/internal External/internal [mm] 54 42 35 27 0.25 0.68 0.92 1.25 0.25 0.62 0.85 1.10 1.37 1.75 0.25 0.62 0.87 1.17 1.39 1.99 0.25 0.63 0.88 1.14 1.40 1.99 11 29 20 22 11 29 20 22 44 45 11 29 20 22 44 45 11 29 20 22 44 45 6+6 6+6 6+6 6+6 10+10 10+6 6+6 6+6 6+6 6+6 10+10 10+10 10+6 10+6 6+6 6+6 10+10 10+10 10+10 10+6 10+6 10+6 32/26 32/26 32/26 32/26 32/22.8 32/22.8 32/26 32/26 32/26 32/26 32/22.8 32/22.8 32/22.8 32/22.8 32/26 32/26 32/22.8 32/22.8 32/22.8 32/22.8 32/22.8 32/22.8 40/32.6 40/32.6 40/32.6 40/32.6 40/28.4 40/32.6 40/32.6 40/32.6 40/32.6 40/32.6 40/28.4 40/28.4 40/32.6 40/32.6 40/32.6 40/32.6 40/28.4 40/28.4 40/28.4 40/32.6 40/32.6 40/32.6 76 76 76 76 80 76 76 76 76 76 80 80 76 76 76 76 80 80 80 76 76 76

CR(I) 5-11

2.2

519

840

85

178

110

65 50 45 40 35 28

CR(I) 5-13

2.2

573

894

85

178

110

79 63 54 45 40 33

CR(I) 5-15

2.2

627

948

85

178

110

93 73 62 53 46 37

Note: For information about electrical data, see pages 155 to 156.

CR deep-well pumps, 60 Hz
Dimensions and weights
Motor P2 [kW] 2.2 Dimensions [mm] B1 384 B1+B2 705 C1 85 D1 179 D2 110 Flow Suction depth, HD rate [m] [m3/h] 52 45 41 37 34 30 CR(I) 5-8 2.2 438 759 85 179 110 65 60 53 50 45 CR(I) 5-9 2.2 465 786 85 179 110 73 65 60 55 50 47 Note: For information about electrical data, see pages 155 to 156. 0.33 0.69 0.91 1.16 1.35 1.65 0.38 0.60 0.94 1.10 1.37 0.37 0.68 0.88 1.11 1.39 1.63 Pipe dimensions [mm] Largest Pressure class, ejector plastic pipe Ejector inlet: Ejector outlet: diameter [kp/cm2] External/internal External/internal [mm] 6+6 6+6 6+6 6+6 6+6 6+6 10+10 10+6 6+6 6+6 6+6 10+10 10+10 10+6 10+6 6+6 6+6 32/26 32/26 32/26 32/26 32/26 32/26 32/22.8 32/22.8 32/26 32/26 32/26 32/22.8 32/22.8 32/22.8 32/22.8 32/26 32/26 40/32.6 40/32.6 40/32.6 40/32.6 40/32.6 40/32.6 40/28.4 40/32.6 40/32.6 40/32.6 40/32.6 40/28.4 40/28.4 40/32.6 40/32.6 40/32.6 40/32.6 76 76 76 76 76 76 80 76 76 76 76 80 80 76 76 76 76

Pump CR(I) 5-6

Ejector No 11 29 20 22 44 45 11 29 20 22 44 11 29 20 22 44 45

Technical data
112

Technical data
CR low-NPSH pumps CR pumps with 4-pole motor
Dimensional drawings

CR low-NPSH pumps CR pumps with 4-pole motor 50 and 60 Hz

D2 D1

B2

CR 1 CR 3
B1

G 1/2

G 1/2

FGJ (DIN-ANSI-JIS) PN 25 / DN 25/32


G 1/2 19 x 24.5 G 1/2 22 75 89 100 140

A (Oval)

100 141 250

35 180 220

4 x 13.5

100 145 160

75 180 220

4 x 13.5

D2 D1

B2

G 1/2

G 1/2 D3

CR 5
FGJ (DIN-ANSI-JIS) PN 25 / DN 25/32
G 1/2 19 x 24.5

B1

A (Oval)

G 1/2 22
75 89 100 140

100 141 250

35 180 220

4 x 13.5

100 145 160

75 180 220

4 x 13.5

TM03 1723 2805

Rp 1 1/4" M10 x 40

50

20

20

TM03 1721 2805

Rp 1 M10 x 40

50

20

20

113

Technical data

Technical data

CR low-NPSH pumps CR pumps with 4-pole motor 50 and 60 Hz

D2 D1

CR 10

B2

G 1/2

G 1/2

D3

FJ (DIN-JIS) PN 16-25 / DN 40 B1 G 1/2 18 x 20.2 39 114 150 G 1/2 27 20

A (oval) Rp 1 1/2" M12 x 45 4 x 13.5

130 178 280

110 215 256

4 x 13.5

130 178 200

100 215 256

D2 D1

B2

G 1/2

CR 15 CR 20
B1

G 1/2

D3

F (DIN) PN 16-25 / DN 50
G 1/2 4 x 13.5 18.1 125 165 18 x 21.5 G 1/2 20

GJ (ANSI-JIS)
65 G 1/2 30 127 165 M12 x 45

A (oval)
Rp 2"

90

90

90

20

215 256

D2 D1

B2

CR 32
G 1/2

D3

PN16-25-40/DN65 B1 G 1/2 8 x 18

Technical data

105

170 223 320

30

74 240 298

114

107 145 185

G 1/2

4 x 14

TM01 1749 5197

TM03 1727 2805

130 176 300

65

130 176 300

120 215 256

130 178 200

130 215 256

20

TM03 1725 2805

20

80

80

Technical data
D2 D1

CR low-NPSH pumps CR pumps with 4-pole motor 50 and 60 Hz

B2

CR 45
G 1/2

D3

PN16-25-40/DN80 B1 G 1/2 8 x 18

140

190 248 365 D2 D1

80 266 331

45

F (DIN) PN25-40/DN100 8 x 22 B2

CR 64
G 1/2

D3

45

100

266 331 F (DIN) PN16/DN100

B1

G 1/2

8 x 18

150 190 235

G 1/2

120 160 200

G 1/2

4 x 14

4 x 14

140

190 248 365 D2 D1

45

100

266 331

F (DIN) PN25-40/DN100 8 x 22 B2

45

CR 90
G 1/2

D3

100

280 348 F (DIN) PN16/DN100

B1

G 1/2

156 190 235

G 1/2

8 x 18

150 180 220

G 1/2

4 x 14

4 x 14

140

156 180 220

G 1/2

TM01 1755 2203

TM01 1753 5197

TM01 1751 5197

Technical data

199 261 380

45

100

4 x 14

280 348

115

Technical data

CR pumps with 4-pole motor 50 and 60 Hz

CR 120 CR 150

Technical data

116

TM03 5999 4106

Technical data
CR low-NPSH pump
Dimensions and weights CR 3 low-NPSH pumps, 50 Hz
CR Pump type Motor P2 [kW] B1 CR 3-3 CR 3-4 CR 3-5 CR 3-6 CR 3-7 CR 3-8 CR 3-9 CR 3-10 CR 3-11 CR 3-12 CR 3-13 CR 3-15 CR 3-17 CR 3-19 CR 3-21 CR 3-23 CR 3-25 CR 3-27 CR 3-29 CR 3-31 CR 3-33 CR 3-36 0.37 0.37 0.55 0.55 0.55 0.75 0.75 0.75 1.1 1.1 1.1 1.1 1.5 1.5 2.2 2.2 2.2 2.2 2.2 3.0 3.0 3.0 279 297 315 333 351 375 393 411 429 447 465 501 553 589 625 661 697 733 769 809 845 899 Dimension [mm] DIN flange B1+B2 470 488 506 524 542 606 624 642 660 678 696 732 834 870 946 982 1018 1054 1090 1144 1180 1234 Oval flange B1 254 272 290 308 326 350 368 386 404 422 440 476 528 564 600 636 B1+B2 445 463 481 499 517 581 599 617 635 653 671 707 809 845 921 957 D1 141 141 141 141 141 141 141 141 141 141 141 141 178 178 178 178 178 178 178 198 198 198 D2 109 109 109 109 109 109 109 109 109 109 109 109 110 110 110 110 110 110 110 120 120 120 D3 -

CR low-NPSH pumps 50 Hz

Net weight [kg] DIN flange 23 23 24.5 25 25 27 28 28 31 31 31 32 40 41 42 43 44 45 46 51 51 53 Oval flange 18 19 19.5 20 21 23 23 24 26 26 27 28 36 37 38 39 -

Note: CR 3 low-NPSH pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 155 to 156.

117

Technical data

Technical data
CR 5 low-NPSH pumps, 50 Hz
CR Pump type Motor P2 [kW] B1 CR 5-4 CR 5-5 CR 5-6 CR 5-7 CR 5-8 CR 5-9 CR 5-10 CR 5-11 CR 5-12 CR 5-13 CR 5-14 CR 5-15 CR 5-16 CR 5-18 CR 5-20 CR 5-22 CR 5-24 CR 5-26 CR 5-29 CR 5-32 CR 5-36 0.75 0.75 1.1 1.1 1.1 1.5 1.5 2.2 2.2 2.2 2.2 2.2 2.2 3.0 3.0 4.0 4.0 4.0 4.0 5.5 5.5 333 366 393 420 447 490 517 544 571 598 625 652 679 737 791 845 899 953 1034 1145 1253 Dimension [mm] DIN flange B1+B2 564 597 624 651 678 771 798 865 892 919 946 973 1000 1072 1126 1217 1271 1325 1406 1536 1644 Oval flange B1 308 341 368 395 422 465 492 519 546 573 600 627 654 712 766 820 B1+B2 539 572 599 626 653 746 773 840 867 894 921 948 975 1047 1101 1194 D1 141 141 141 141 141 178 178 178 178 178 178 178 178 198 198 220 220 220 220 220 220 D2 109 109 109 109 109 110 110 110 110 110 110 110 110 120 120 134 134 134 134 134 134 D3 300 300

CR low-NPSH pumps 50 Hz

Net weight [kg] DIN flange 26.5 27 30 30 31 38 39 40 41 41 42 43 43 48 50 62 63 64 66 82 84 Oval flange 21.5 22 25 26 26 34 34 36 36 37 37 38 38 44 45 56 -

Note: CR 5 low-NPSH pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 155 to 156.

CR 10 low-NPSH pumps, 50 Hz
CR Pump type Motor P2 [kW] B1 CR 10-3 CR 10-4 CR 10-5 CR 10-6 CR 10-7 CR 10-8 CR 10-9 CR 10-10 CR 10-12 CR 10-14 CR 10-16 CR 10-18 CR 10-20 CR 10-22 1.1 1.5 2.2 2.2 3.0 3.0 4.0 4.0 4.0 5.5 5.5 7.5 7.5 7.5 377 423 453 483 518 548 578 608 668 760 820 880 940 1000 Dimension [mm] DIN flange B1+B2 608 704 734 764 853 883 950 980 1040 1151 1211 1271 1331 1391 Oval flange B1 377 423 453 483 518 548 578 608 668 760 820 B1+B2 608 704 734 764 853 883 950 980 1040 1151 1211 D1 141 178 178 178 198 198 220 220 220 220 220 220 220 220 D2 109 110 110 110 120 120 134 134 134 134 134 134 134 134 D3 300 300 300 300 300 Net weight [kg] DIN flange 39 47 49 50 55 56 68 69 71 94 96 113 115 117 Oval flange 37 45 46 47 52 53 65 66 69 91 93 -

Note: CR 10 low-NPSH pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 155 to 156.

Technical data
118

Technical data
CR 15 low-NPSH pumps, 50 Hz
CR Pump type Motor P2 [kW] B1 CR 15-2 CR 15-3 CR 15-4 CR 15-5 CR 15-6 CR 15-7 CR 15-8 CR 15-9 CR 15-10 CR 15-12 CR 15-14 CR 15-17 3.0 4.0 4.0 5.5 5.5 7.5 7.5 11.0 11.0 11.0 15.0 15.0 415 465 510 555 632 677 722 767 889 979 1069 1204 Dimension [mm] DIN flange B1+B2 750 837 882 946 1023 1068 1113 1238 1360 1450 1540 1675 Oval flange B1 415 465 510 555 632 677 B1+B2 750 837 882 946 1023 1068 D1 198 220 220 220 220 220 220 314 314 314 314 314 D2 120 134 134 134 134 134 134 204 204 204 204 204 D3 300 300 300 350 350 350 350 350

CR low-NPSH pumps 50 Hz

Net weight [kg] DIN flange 54 66 68 75 91 108 109 128 132 136 165 177 Oval flange 53 65 67 74 90 107 -

Note: CR 15 low-NPSH pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 155 to 156.

CR 20 low-NPSH pumps, 50 Hz
CR Pump type Motor P2 [kW] B1 CR 20-2 CR 20-3 CR 20-4 CR 20-5 CR 20-6 CR 20-7 CR 20-8 CR 20-10 CR 20-12 CR 20-14 CR 20-17 3.0 4.0 5.5 7.5 7.5 11.0 11.0 11.0 15.0 15.0 18.5 415 465 542 587 632 677 799 889 979 1069 1204 Dimension [mm] DIN flange B1+B2 736 837 933 978 1023 1148 1270 1360 1450 1540 1719 Oval flange B1 415 465 542 587 632 677 B1+B2 736 837 933 978 1023 1148 D1 178 220 220 220 220 314 314 314 314 314 314 D2 110 134 134 134 134 204 204 204 204 204 204 D3 300 300 300 300 350 350 350 350 350 Net weight [kg] DIN flange 50 66 88 102 105 139 129 132 168 172 199 Oval flange 49 65 87 101 104 138 -

Note: CR 20 low-NPSH pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 155 to 156.

119

Technical data

Technical data
CR 32 low-NPSH pumps, 50 Hz
CR Pump type Motor P2 [kW] B1 CR 32-1-1 CR 32-2 CR 32-3-2 CR 32-3 CR 32-4-2 CR 32-4 CR 32-5-2 CR 32-5 CR 32-6-2 CR 32-6 CR 32-7-2 CR 32-7 CR 32-8-2 CR 32-8 CR 32-9-2 CR 32-9 CR 32-10-2 CR 32-10 CR 32-11-2 CR 32-11 CR 32-12-2 CR 32-12 CR 32-13-2 CR 32-13 CR 32-14-2 CR 32-14 1.5 4.0 5.5 5.5 7.5 7.5 11.0 11.0 11.0 11.0 15.0 15.0 15.0 15.0 18.5 18.5 18.5 18.5 22.0 22.0 22.0 22.0 30.0 30.0 30.0 30.0 505 575 645 645 715 715 895 895 965 965 1035 1035 1105 1105 1175 1175 1245 1245 1315 1315 1385 1385 1455 1455 1525 1525 Dimension [mm] DIN flange B1+B2 786 947 1036 1036 1106 1106 1366 1366 1436 1436 1506 1506 1576 1576 1690 1690 1760 1760 1856 1856 1926 1926 2101 2101 2171 2171 Oval flange B1 B1+B2 D1 178 220 220 220 220 220 314 314 314 314 314 314 314 314 314 314 314 314 314 314 314 314 415 415 415 415 D2 110 134 134 134 134 134 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 300 300 300 300 D3 135 158 298 298 298 298 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 400 400 400 400

CR low-NPSH pumps 50 Hz

Net weight [kg] DIN flange 61 87 107 107 129 129 157 157 160 160 195 195 198 198 223 223 226 226 247 247 251 251 322 322 325 325 Oval flange -

Note: CR 32 low-NPSH pumps are also available as CRN pumps with PJE connection. For information about electrical data, see pages 155 to 156.

Technical data
120

Technical data
CR 45 low-NPSH pumps, 50 Hz
CR Pump type Motor P2 [kW] B1 CR 45-2 CR 45-3-2 CR 45-3 CR 45-4-2 CR 45-4 CR 45-5-2 CR 45-5 CR 45-6-2 CR 45-6 CR 45-7-2 CR 45-7 CR 45-8-2 CR 45-8 CR 45-9-2 CR 45-9 CR 45-10-2 CR 45-10 CR 45-11-2 CR 45-11 CR 45-12-2 CR 45-12 CR 45-13-2 7.5 11.0 11.0 15.0 15.0 18.5 18.5 22.0 22.0 30.0 30.0 30.0 30.0 30.0 37.0 37.0 37.0 45.0 45.0 45.0 45.0 45.0 639 829 829 909 909 989 989 1069 1069 1149 1149 1229 1229 1309 1309 1389 1389 1469 1469 1549 1549 1629 Dimension [mm] DIN flange B1+B2 1030 1300 1300 1380 1380 1504 1504 1610 1610 1795 1795 1875 1875 1955 2012 2092 2092 2178 2178 2258 2258 2338 Oval flange B1 B1+B2 D1 220 314 314 314 314 314 314 314 314 415 415 415 415 415 415 415 415 442 442 442 442 442 D2 134 204 204 204 204 204 204 204 204 300 300 300 300 300 300 300 300 325 325 325 325 325 D3 298 350 350 350 350 350 350 350 350 400 400 400 400 400 400 400 400 450 450 450 450 450

CR low-NPSH pumps 50 Hz

Net weight [kg] DIN flange 122 151 151 189 189 216 216 237 237 321 321 336 336 341 361 366 366 478 478 483 483 488 Oval flange -

Note: CR 45 low-NPSH pumps are also available as CRN pumps with PJE connection. For information about electrical data, see pages 155 to 156.

CR 64 low-NPSH pumps, 50 Hz
CR Pump type Motor P2 [kW] B1 CR 64-2-1 CR 64-2 CR 64-3-2 CR 64-3-1 CR 64-3 CR 64-4-2 CR 64-4-1 CR 64-4 CR 64-5-2 CR 64-5-1 CR 64-5 CR 64-6-2 CR 64-6-1 CR 64-6 CR 64-7-2 CR 64-7-1 CR 64-7 CR 64-8-2 CR 64-8-1 11.0 11.0 15.0 15.0 18.5 18.5 22.0 22.0 30.0 30.0 30.0 30.0 37.0 37.0 37.0 37.0 45.0 45.0 45.0 754 754 836 836 836 919 919 919 1001 1001 1001 1084 1084 1084 1166 1166 1166 1249 1249 Dimension [mm] DIN flange B1+B2 1225 1225 1307 1307 1351 1434 1460 1460 1647 1647 1647 1730 1787 1787 1869 1869 1875 1958 1958 Oval flange B1 B1+B2 D1 314 314 314 314 314 314 314 314 415 415 415 415 415 415 415 415 442 442 442 D2 204 204 204 204 204 204 204 204 300 300 300 300 300 300 300 300 325 325 325 D3 350 350 350 350 350 350 350 350 400 400 400 400 400 400 400 400 450 450 450 Net weight [kg] DIN flange 151 151 194 194 216 226 242 242 316 316 316 336 356 356 376 376 440 473 473 Oval flange -

Note: CR 64 low-NPSH pumps are also available as CRN pumps with PJE connection. For information about electrical data, see pages 155 to 156.

121

Technical data

Technical data
CR 3 low-NPSH pumps, 60 Hz
CR Pump type Motor P2 [kW] B1 CR 3-3 CR 3-4 CR 3-5 CR 3-6 CR 3-7 CR 3-8 CR 3-9 CR 3-10 CR 3-11 CR 3-12 CR 3-13 CR 3-15 CR 3-17 CR 3-19 CR 3-21 CR 3-23 CR 3-25 0.55 0.55 0.75 1.1 1.1 1.1 1.5 1.5 1.5 2.2 2.2 2.2 2.2 3.0 3.0 3.0 4.0 279 297 321 339 357 375 409 427 445 463 481 517 553 593 629 665 701 Dimension [mm] DIN flange B1+B2 470 488 552 570 588 606 690 708 726 784 802 838 874 928 964 1000 1073 Oval flange B1 254 272 296 314 332 350 384 402 420 438 456 492 528 B1+B2 445 463 527 545 563 581 665 683 701 759 777 813 849 D1 141 141 141 141 141 141 178 178 178 178 178 178 178 198 198 198 220 D2 109 109 109 109 109 109 110 110 110 110 110 110 110 120 120 120 134 D3 -

CR low-NPSH pumps 60 Hz

Net weight [kg] DIN flange 24 24 26 29 29 29 37 37 38 39 39 40 41 46 47 47 59 Oval flange 19 19 22 24 24 25 32 33 33 34 34 35 36 -

Note: CR 3 low-NPSH pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 155 to 156.

CR 5 low-NPSH pumps, 60 Hz
CR Pump type Motor P2 [kW] B1 CR 5-4 CR 5-5 CR 5-6 CR 5-7 CR 5-8 CR 5-9 CR 5-10 CR 5-11 CR 5-12 CR 5-13 CR 5-14 CR 5-15 CR 5-16 CR 5-18 CR 5-20 CR 5-22 CR 5-24 1.1 1.5 2.2 2.2 2.2 2.2 3.0 3.0 3.0 4.0 4.0 4.0 4.0 5.5 5.5 5.5 7.5 339 382 409 436 463 490 521 548 575 602 629 656 683 767 821 875 929 Dimension [mm] DIN flange B1+B2 570 663 730 757 784 811 856 883 910 974 1001 1028 1055 1158 1212 1266 1308 Oval flange B1 314 357 384 411 438 465 496 523 550 577 604 631 658 B1+B2 545 638 705 732 759 786 831 858 885 949 976 1003 1030 D1 141 178 178 178 178 178 198 198 198 220 220 220 220 220 220 220 220 D2 109 110 110 110 110 110 120 120 120 134 134 134 134 134 134 134 134 D3 300 300 300 300 Net weight [kg] DIN flange 28 36 37 38 38 39 44 44 45 56 57 58 58 74 75 76 79 Oval flange 24 32 33 33 34 34 39 40 40 52 53 53 54 -

Note: CR 5 low-NPSH pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 155 to 156.

Technical data
122

Technical data
CR 10 low-NPSH pumps, 60 Hz
CR Pump type Motor P2 [kW] B1 CR 10-3 CR 10-4 CR 10-5 CR 10-6 CR 10-7 CR 10-8 CR 10-9 CR 10-10 CR 10-12 CR 10-14 CR 10-16 CR 10-17 2.2 3.0 4.0 4.0 5.5 5.5 5.5 7.5 7.5 11.0 11.0 11.0 393 428 458 488 550 580 610 640 700 837 897 957 Dimension [mm] DIN flange B1+B2 674 763 830 860 941 971 1001 1019 1079 1308 1368 1428 Oval flange B1 393 428 458 488 550 580 610 640 B1+B2 674 763 830 860 941 971 1001 1019 D1 198 198 220 220 220 220 220 220 220 314 314 314 D2 120 120 134 134 134 134 134 134 134 204 204 204 D3 300 300 300 300 300 350 350 350

CR low-NPSH pumps 60 Hz

Net weight [kg] DIN flange 47 52 64 65 87 88 89 104 106 129 131 133 Oval flange 44 49 61 62 84 85 86 101 -

Note: CR 10 low-NPSH pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 155 to 156.

CR 15 low-NPSH pumps, 60 Hz
CR Pump type Motor P2 [kW] B1 CR 15-2 CR 15-3 CR 15-4 CR 15-5 CR 15-6 CR 15-7 CR 15-8 CR 15-9 CR 15-10 CR 15-12 5.5 5.5 7.5 11.0 11.0 15.0 15.0 15.0 18.5 18.5 420 465 542 587 709 754 799 844 889 979 Dimension [mm] DIN flange B1+B2 811 856 921 1058 1180 1225 1270 1315 1404 1494 Oval flange B1 420 465 542 587 B1+B2 811 856 921 1058 D1 220 220 220 314 314 314 314 314 314 314 D2 134 134 134 204 204 204 204 204 204 204 D3 300 300 350 350 350 350 350 350 Net weight [kg] DIN flange 71 72 103 136 126 152 154 163 175 190 Oval flange 70 71 102 135 -

Note: CR 15 low-NPSH pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 155 to 156.

CR 20 low-NPSH pumps, 60 Hz
CR Pump type Motor P2 [kW] B1 CR 20-2 CR 20-3 CR 20-4 CR 20-5 CR 20-6 CR 20-7 CR 20-8 5.5 7.5 11.0 11.0 15.0 15.0 18.5 420 497 542 664 709 754 799 Dimension [mm] DIN flange B1+B2 811 876 1013 1135 1180 1225 1314 Oval flange B1 420 497 542 664 B1+B2 811 876 1013 1135 D1 220 220 314 314 314 314 314 D2 134 134 204 204 204 204 204 D3 300 350 350 350 350 350 Net weight [kg] DIN flange 71 102 134 124 151 159 171 Oval flange 70 101 133 123 -

Note: CR 20 low-NPSH pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 155 to 156.

123

Technical data

Technical data
CR 32 low-NPSH pumps, 60 Hz
CR Pump type Motor P2 [kW] B1 CR 32-2-1 CR 32-2 CR 32-3-2 CR 32-3 CR 32-4-2 CR 32-4 CR 32-5-2 CR 32-5 CR 32-6-2 CR 32-6 CR 32-7-2 CR 32-7 CR 32-8-2 CR 32-8 CR 32-9-2 CR 32-9 CR 32-10-2 5.5 7.5 11.0 11.0 11.0 15.0 15.0 18.5 18.5 18.5 22.0 22.0 30.0 30.0 30.0 30.0 30.0 575 575 755 755 825 825 895 895 965 965 1035 1035 1105 1105 1175 1175 1245 Dimension [mm] DIN flange B1+B2 966 954 1226 1226 1296 1296 1366 1410 1480 1480 1576 1576 1751 1751 1821 1821 1891 Oval flange B1 B1+B2 D1 220 220 314 314 314 314 314 314 314 314 314 314 415 415 415 415 415 D2 148 134 204 204 204 204 204 204 204 204 204 204 300 300 300 300 300 D3 298 298 350 350 350 350 350 350 350 350 350 350 400 400 400 400 400

CR low-NPSH pumps 60 Hz

Net weight [kg] DIN flange 98 112 146 146 154 186 189 211 214 214 233 233 305 305 308 308 311 Oval flange -

Note: CR 32 low-NPSH pumps are also available as CRN pumps with PJE connection. For information about electrical data, see pages 155 to 156.

CR 45 low-NPSH pumps, 60 Hz
CR Pump type Motor P2 [kW] B1 CR 45-2-1 CR 45-2 CR 45-3-2 CR 45-3-1 CR 45-3 CR 45-4-2 CR 45-4-1 CR 45-4 CR 45-5-2 CR 45-5-1 CR 45-5 CR 45-6-2 CR 45-6-1 CR 45-6 CR 45-7-2 CR 45-7-1 CR 45-7 11.0 15.0 18.5 18.5 18.5 22.0 30.0 30.0 30.0 30.0 30.0 37.0 37.0 37.0 45.0 45.0 45.0 749 749 829 829 829 909 909 909 989 989 989 1069 1069 1069 1149 1149 1149 Dimension [mm] DIN flange B1+B2 1220 1220 1344 1344 1344 1450 1555 1555 1635 1635 1635 1772 1772 1772 1858 1858 1858 Oval flange B1 B1+B2 D1 314 314 314 314 314 314 415 415 415 415 415 415 415 415 442 442 442 D2 204 204 204 204 204 204 300 300 300 300 300 300 300 300 325 325 325 D3 350 350 350 350 350 350 400 400 400 400 400 400 400 400 450 450 450 Net weight [kg] DIN flange 147 179 205 205 205 227 296 296 301 301 301 326 326 326 405 405 405 Oval flange -

Note: CR 45 low-NPSH pumps are also available as CRN pumps with PJE connection. For information about electrical data, see pages 155 to 156.

Technical data
124

Technical data
CR 64 low-NPSH pumps, 60 Hz
CR Pump type Motor P2 [kW] B1 CR 64-2-1 CR 64-2 CR 64-3-2 CR 64-3-1 CR 64-3 CR 64-4-2 CR 64-4-1 CR 64-4 CR 64-5-2 18.5 22.0 22.0 30.0 30.0 37.0 37.0 45.0 45.0 754 754 836 836 836 919 919 919 1001 Dimension [mm] DIN flange B1+B2 1269 1295 1377 1482 1482 1622 1622 1628 1710 Oval flange B1 B1+B2 D1 314 314 314 415 415 415 415 442 442 D2 204 204 204 300 300 300 300 325 325 D3 350 350 350 400 400 400 400 450 450

CR low-NPSH pumps 60 Hz

Net weight [kg] DIN flange 205 221 232 301 301 331 331 395 400 Oval flange -

Note: CR 64 low-NPSH pumps are also available as CRN pumps with PJE connection. For information about electrical data, see pages 155 to 156.

125

Technical data

Technical data
CR pumps with 4-pole motor
Dimensions and weights CR 1 with 4-pole motor, 50 Hz
CR Pump type Motor P2 [kW] B1 CR 1-2 CR 1-3 CR 1-4 CR 1-5 CR 1-6 CR 1-7 CR 1-8 CR 1-9 CR 1-10 CR 1-11 CR 1-12 CR 1-13 CR 1-15 CR 1-17 CR 1-19 CR 1-21 CR 1-23 CR 1-25 CR 1-27 CR 1-30 CR 1-33 CR 1-36 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 279 279 297 315 333 351 369 387 405 423 447 465 501 537 573 609 645 697 733 787 841 895 Dimension [mm] DIN flange B1+B2 470 470 488 506 524 542 560 578 596 614 638 656 692 728 764 800 836 888 924 978 1032 1086 Oval flange B1 254 254 272 290 308 326 344 362 380 398 422 440 476 512 548 584 620 B1+B2 445 445 463 481 499 517 535 553 571 589 613 631 667 703 739 775 811 D1 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 D2 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109

CR pumps with 4-pole motor 50 Hz

Net weight [kg] D3 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 DIN flange 22 22 22 23 23 24 25 25 25 26 28 28 29 32 33 34 35 43 43 45 46 48 Oval flange 17 17 18 18 19 19 20 20 21 21 23 24 25 28 28 29 30 -

Note: 4-pole CR 1 pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 155 to 156.

Technical data
126

Technical data
CR 3 with 4-pole motor, 50 Hz
CR Pump type Motor P2 [kW] B1 CR 3-2 CR 3-3 CR 3-4 CR 3-5 CR 3-6 CR 3-7 CR 3-8 CR 3-9 CR 3-10 CR 3-11 CR 3-12 CR 3-13 CR 3-15 CR 3-17 CR 3-19 CR 3-21 CR 3-23 CR 3-25 CR 3-27 CR 3-29 CR 3-31 CR 3-33 CR 3-36 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.37 0.37 0.37 0.37 279 279 297 315 333 351 375 393 411 429 447 465 501 553 589 625 661 697 733 769 809 845 899 Dimension [mm] DIN flange B1+B2 470 470 488 506 524 542 566 584 602 620 638 656 692 744 780 816 852 888 924 960 1000 1036 1090 Oval flange B1 254 254 272 290 308 326 350 368 386 404 422 440 476 528 564 600 636 B1+B2 445 445 463 481 499 517 541 559 577 595 613 631 667 719 755 791 827 D1 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 D2 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109

CR pumps with 4-pole motor 50 Hz

Net weight [kg] D3 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 DIN flange 22 22 22 23 24 24 26 27 27 30 30 30 31 39 40 41 42 43 44 46 51 51 53 Oval flange 17 17 18 18 19 20 22 22 23 25 25 26 27 35 36 37 38 -

Note: 4-pole CR 3 pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 155 to 156.

127

Technical data

Technical data
CR 5 with 4-pole motor, 50 Hz
CR Pump type Motor P2 [kW] B1 CR 5-2 CR 5-3 CR 5-4 CR 5-5 CR 5-6 CR 5-7 CR 5-8 CR 5-9 CR 5-10 CR 5-11 CR 5-12 CR 5-13 CR 5-14 CR 5-15 CR 5-16 CR 5-18 CR 5-20 CR 5-22 CR 5-24 CR 5-26 CR 5-29 CR 5-32 CR 5-36 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.37 0.37 0.37 0.37 0.55 0.55 0.55 0.55 0.75 279 306 333 366 393 420 447 490 517 544 571 598 625 652 679 737 791 845 899 953 1034 1145 1253 Dimension [mm] DIN flange B1+B2 470 497 524 557 584 611 638 681 708 735 762 789 816 843 870 928 982 1036 1130 1184 1265 1376 1484 Oval flange B1 254 281 308 341 368 395 422 465 492 519 546 573 600 627 654 712 766 820 B1+B2 445 472 499 532 559 586 613 656 683 710 737 764 791 818 845 903 957 1011 D1 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 D2 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109

CR pumps with 4-pole motor 50 Hz

Net weight [kg] D3 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 120 120 120 120 120 DIN flange 22 23 24 26 29 29 30 37 38 39 40 40 41 42 43 48 50 62 62 63 65 81 83 Oval flange 17 19 19 21 24 25 25 33 33 35 35 36 36 37 38 44 45 56 -

Note: 4-pole CR 5 pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 155 to 156.

CR 10 with 4-pole motor, 50 Hz


CR Pump type Motor P2 [kW] B1 CR 10-1 CR 10-2 CR 10-3 CR 10-4 CR 10-5 CR 10-6 CR 10-7 CR 10-8 CR 10-9 CR 10-10 CR 10-12 CR 10-14 CR 10-16 CR 10-18 CR 10-20 CR 10-22 0.25 0.25 0.25 0.25 0.25 0.25 0.37 0.37 0.37 0.55 0.55 0.75 0.75 0.75 1.1 1.1 343 347 377 423 453 483 518 548 578 608 668 760 820 880 940 1000 Dimension [mm] DIN flange B1+B2 534 538 568 614 644 674 709 739 769 839 899 991 1051 1111 1221 1281 Oval flange B1 343 347 377 423 453 483 518 548 578 608 668 760 820 B1+B2 534 538 568 614 644 674 709 739 769 839 899 991 1051 D1 141 141 141 141 141 141 141 141 141 141 141 141 141 141 178 178 D2 109 109 109 109 109 109 109 109 109 109 109 109 109 109 110 110 D3 105 105 105 105 105 105 105 105 105 120 120 120 120 120 135 135 Net weight [kg] DIN flange 33 35 38 46 48 49 55 56 57 68 70 93 95 100 98 100 Oval flange 30 33 36 44 45 46 52 53 54 65 68 90 92 -

Note: 4-pole CR 10 pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 155 to 156.

Technical data
128

Technical data
CR 15 with 4-pole motor, 50 Hz
CR Pump type Motor P2 [kW] B1 CR 15-1 CR 15-2 CR 15-3 CR 15-4 CR 15-5 CR 15-6 CR 15-7 CR 15-8 CR 15-9 CR 15-10 CR 15-12 CR 15-14 CR 15-17 0.25 0.25 0.37 0.55 0.55 0.75 0.75 1.1 1.1 1.1 1.5 1.5 2.2 400 415 465 510 555 632 677 722 767 889 979 1069 1204 Dimension [mm] DIN flange B1+B2 591 606 656 741 786 863 908 1003 1048 1170 1260 1350 1539 Oval flange B1 400 415 465 510 555 632 677 B1+B2 591 606 656 741 786 863 908 D1 141 141 141 141 141 141 141 178 178 178 178 178 198 D2 109 109 109 109 109 109 109 110 110 110 110 110 120

CR pumps with 4-pole motor 50 Hz

Net weight [kg] D3 105 105 105 120 120 120 120 135 135 135 135 135 160 DIN flange 41 49 55 67 68 90 92 92 93 125 134 138 157 Oval flange 40 48 54 66 67 89 91 -

Note: 4-pole CR 15 pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 155 to 156.

CR 20 with 4-pole motor, 50 Hz


CR Pump type Motor P2 [kW] B1 CR 20-1 CR 20-2 CR 20-3 CR 20-4 CR 20-5 CR 20-6 CR 20-7 CR 20-8 CR 20-10 CR 20-12 CR 20-14 CR 20-17 0.25 0.37 0.55 0.55 0.75 1.1 1.1 1.1 1.5 2.2 2.2 2.2 400 415 465 542 587 632 677 799 889 979 1069 1204 Dimension [mm] DIN flange B1+B2 591 606 696 773 818 913 958 1080 1170 1314 1404 1539 Oval flange B1 400 415 465 542 587 632 677 B1+B2 591 606 696 773 818 913 958 D1 141 141 141 141 141 178 178 178 178 198 198 198 D2 109 109 109 109 109 110 110 110 110 120 120 120 D3 105 105 120 120 120 135 135 135 135 160 160 160 Net weight [kg] DIN flange 41 50 65 87 89 88 90 122 130 148 152 187 Oval flange 40 49 64 86 88 -

Note: 4-pole CR 20 pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 155 to 156.

129

Technical data

Technical data
CR 32 with 4-pole motor, 50 Hz
CR Pump type Motor P2 [kW] B1 CR 32-1-1 CR 32-1 CR 32-2-2 CR 32-2 CR 32-3-2 CR 32-3 CR 32-4-2 CR 32-4 CR 32-5-2 CR 32-5 CR 32-6-2 CR 32-6 CR 32-7-2 CR 32-7 CR 32-8-2 CR 32-8 CR 32-9-2 CR 32-9 CR 32-10-2 CR 32-10 CR 32-11-2 CR 32-11 CR 32-12-2 CR 32-12 CR 32-13-2 CR 32-13 CR 32-14-2 CR 32-14 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.2 2.2 2.2 2.2 2.2 2.2 2.2 3.0 3.0 3.0 3.0 3.0 3.0 3.0 505 505 575 575 645 645 715 715 895 895 965 965 1035 1035 1105 1105 1175 1175 1245 1245 1315 1315 1385 1385 1455 1455 1525 1525 Dimension [mm] DIN flange B1+B2 786 786 856 856 926 926 996 996 1176 1176 1246 1246 1316 1316 1440 1440 1510 1510 1580 1580 1650 1650 1720 1720 1790 1790 1860 1860 Oval flange B1 B1+B2 D1 178 178 178 178 178 178 178 178 178 178 178 178 178 178 198 198 198 198 198 198 198 198 198 198 198 198 198 198 D2 110 110 110 110 110 110 110 110 110 110 110 110 110 110 120 120 120 120 120 120 120 120 120 120 120 120 120 120

CR pumps with 4-pole motor 50 Hz

Net weight [kg] D3 135 135 135 135 135 135 135 135 135 135 135 135 135 135 160 160 160 160 160 160 160 160 160 160 160 160 160 160 DIN flange 61 62 76 87 107 107 117 117 155 155 158 158 175 175 178 178 211 211 214 214 250 249 253 253 321 321 324 324 Oval flange -

Note: 4-pole CR 32 pumps are also available as CRN pumps with PJE connection. For information about electrical data, see pages 155 to 156.

Technical data
130

Technical data
CR 45 with 4-pole motor, 50 Hz
CR Pump type Motor P2 [kW] B1 CR 45-1-1 CR 45-1 CR 45-2-2 CR 45-2 CR 45-3-2 CR 45-3 CR 45-4-2 CR 45-4 CR 45-5-2 CR 45-5 CR 45-6-2 CR 45-6 CR 45-7-2 CR 45-7 CR 45-8-2 CR 45-8 CR 45-9-2 CR 45-9 CR 45-10-2 CR 45-10 CR 45-11-2 CR 45-11 CR 45-12-2 CR 45-12 CR 45-13-2 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.2 2.2 2.2 3.0 3.0 3.0 3.0 4.0 4.0 4.0 4.0 4.0 4.0 5.5 5.5 5.5 5.5 5.5 559 559 639 639 829 829 909 909 989 989 1069 1069 1149 1149 1229 1229 1309 1309 1389 1389 1469 1469 1549 1549 1629 Dimension [mm] DIN flange B1+B2 840 840 920 920 1110 1110 1190 1244 1324 1324 1404 1404 1484 1484 1601 1601 1681 1681 1761 1761 1848 1848 1928 1928 2008 Oval flange B1 B1+B2 D1 178 178 178 178 178 178 178 198 198 198 198 198 198 198 220 220 220 220 220 220 260 260 260 260 260 D2 110 110 110 110 110 110 110 120 120 120 120 120 120 120 134 134 134 134 134 134 159 159 159 159 159

CR pumps with 4-pole motor 50 Hz

Net weight [kg] D3 135 135 135 135 135 135 135 160 160 160 160 160 160 160 160 160 160 160 160 160 300 300 300 300 300 DIN flange 80 91 108 110 149 149 169 169 204 204 239 239 320 320 336 336 341 361 366 366 487 487 492 492 497 Oval flange -

Note: 4-pole CR 45 pumps are also available as CRN pumps with PJE connection. For information about electrical data, see pages 155 to 156.

131

Technical data

Technical data
CR 64 with 4-pole motor, 50 Hz
CR Pump type Motor P2 [kW] B1 CR 64-1-1 CR 64-1 CR 64-2-2 CR 64-2-1 CR 64-2 CR 64-3-2 CR 64-3-1 CR 64-3 CR 64-4-2 CR 64-4-1 CR 64-4 CR 64-5-2 CR 64-5-1 CR 64-5 CR 64-6-2 CR 64-6-1 CR 64-6 CR 64-7-2 CR 64-7-1 CR 64-7 CR 64-8-2 CR 64-8-1 1.5 1.5 1.5 1.5 1.5 2.2 2.2 2.2 3.0 3.0 3.0 3.0 4.0 4.0 4.0 4.0 4.0 5.5 5.5 5.5 5.5 5.5 561 561 644 754 754 836 836 836 919 919 919 1001 1001 1001 1084 1084 1084 1166 1166 1166 1249 1249 Dimension [mm] DIN flange B1+B2 842 842 925 1035 1035 1171 1171 1171 1254 1254 1254 1336 1373 1373 1456 1456 1456 1545 1545 1545 1628 1628 Oval flange B1 B1+B2 D1 178 178 178 178 178 198 198 198 198 198 198 198 220 220 220 220 220 260 260 260 260 260 D2 110 110 110 110 110 120 120 120 120 120 120 120 134 134 134 134 134 159 159 159 159 159

CR pumps with 4-pole motor 50 Hz

Net weight [kg] D3 135 135 135 135 135 160 160 160 160 160 160 160 160 160 160 160 160 300 300 300 300 300 DIN flange 91 102 114 149 149 174 174 204 213 244 244 315 316 316 336 356 356 385 385 449 482 482 Oval flange -

Note: 4-pole CR 90 pumps are also available as CRN pumps with PJE connection. For information about electrical data, see pages 155 to 156.

CR 90 with 4-pole motor, 50 Hz


CR Pump type Motor P2 [kW] B1 CR 90-1-1 CR 90-1 CR 90-2-2 CR 90-2 CR 90-3-2 CR 90-3 CR 90-4-2 CR 90-4 CR 90-5-2 CR 90-5 CR 90-6-2 CR 90-6 1.5 1.5 1.5 2.2 2.2 3.0 4.0 4.0 4.0 5.5 5.5 5.5 571 571 773 773 865 865 957 957 1049 1049 1141 1141 Dimension [mm] DIN flange B1+B2 852 852 1054 1108 1200 1200 1329 1329 1421 1428 1520 1520 Oval flange B1 B1+B2 D1 178 178 178 198 198 198 220 220 220 260 260 260 D2 110 110 110 120 120 120 134 134 134 159 159 159 D3 135 135 135 160 160 160 160 160 160 300 300 300 Net weight [kg] DIN flange 107 109 150 164 214 244 326 326 366 375 446 446 Oval flange -

Note: 4-pole CR 90 pumps are also available as CRN pumps with PJE connection. For information about electrical data, see pages 155 to 156.

Technical data
132

Technical data
CR 120 with 4-pole motor, 50 HZ
CR Pump type Motor P2 [kW] B1 CR 120-1 CR 120-2-1 CR 120-2 CR 120-3 CR 120-4-1 CR 120-5-1 CR 120-6-1 CR 120-7 1.5 2.2 3.0 4.0 5.5 5.5 7.5 11.0 834 990 990 1145 1301 1456 1642 1797 Dimension [mm] DIN flange B1+B2 1155 1325 1325 1517 1680 1835 2071 2268 Oval flange B1 B1+B2 D1 178 198 198 220 260 260 260 314 D2 110 120 120 134 159 159 159 204

CR pumps with 4-pole motor 50 Hz

Net weight [kg] D3 270 270 270 270 300 300 300 350 DIN flange 113 131 133 148 185 194 220 267 Oval flange -

Note: 4-pole CR 120 pumps are also available as CRN pumps with PJE connection. For information about electrical data, see pages 155 to 156.

CR 150 with 4-pole motor, 50 Hz


CR Pump type Motor P2 [kW] B1 CR 150-1-1 CR 150-1 CR 150-2-1 CR 150-3-2 CR 150-3 CR 150-4-1 CR 150-5-2 CR 150-6 1.5 2.2 3.0 4.0 5.5 5.5 7.5 11.0 834 834 990 1145 1145 1301 1486 1642 Dimension [mm] DIN flange B1+B2 1155 1169 1325 1517 1524 1680 1915 2113 Oval flange B1 B1+B2 D1 178 198 198 220 260 260 260 314 D2 110 120 120 134 159 159 159 204 D3 270 270 270 270 300 300 300 350 Net weight [kg] DIN flange 113 122 133 148 175 184 210 258 Oval flange -

Note: 4-pole CR 150 pumps are also available as CRN pumps with PJE connection. For information about electrical data, see pages 155 to 156.

133

Technical data

Technical data
CR 1 with 4-pole motor, 60 Hz
CR Pump type Motor P2 [kW] B1 CR 1-2 CR 1-3 CR 1-4 CR 1-5 CR 1-6 CR 1-7 CR 1-8 CR 1-9 CR 1-10 CR 1-11 CR 1-12 CR 1-13 CR 1-15 CR 1-17 CR 1-19 CR 1-21 CR 1-23 CR 1-25 CR 1-27 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.37 279 279 297 315 333 357 375 393 411 429 447 465 517 553 589 625 661 697 737 Dimension [mm] DIN flange B1+B2 470 470 488 506 524 548 566 584 602 620 638 656 708 744 780 816 852 888 928 Oval flange B1 254 254 272 290 308 332 350 368 386 404 422 440 492 528 B1+B2 445 445 463 481 499 523 541 559 577 595 613 631 683 719 D1 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 D2 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109

CR pumps with 4-pole motor 60 Hz

Net weight [kg] D3 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 DIN flange 22 22 22 23 24 26 26 27 29 30 30 30 38 39 41 41 42 43 49 Oval flange 17 17 18 19 19 21 22 22 25 25 25 26 34 35 -

Note: 4-pole CR 1 pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 155 to 156.

CR 3 with 4-pole motor, 60 Hz


CR Pump type Motor P2 [kW] B1 CR 3-2 CR 3-3 CR 3-4 CR 3-5 CR 3-6 CR 3-7 CR 3-8 CR 3-9 CR 3-10 CR 3-11 CR 3-12 CR 3-13 CR 3-15 CR 3-17 CR 3-19 CR 3-21 CR 3-23 CR 3-25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.37 0.37 0.37 0.37 0.55 279 279 297 321 339 357 375 409 427 445 463 481 517 553 593 629 665 701 Dimension [mm] DIN flange B1+B2 470 470 488 512 530 548 566 600 618 636 654 672 708 744 784 820 856 932 Oval flange B1 254 254 272 296 314 332 350 384 402 420 438 456 492 528 B1+B2 445 445 463 487 505 523 541 575 593 611 629 647 683 719 D1 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 D2 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 D3 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 120 Net weight [kg] DIN flange 22 23 23 25 28 28 28 36 36 37 38 38 39 41 46 47 47 58 Oval flange 17 18 18 21 23 23 24 31 32 32 33 33 34 36 -

Note: 4-pole CR 3 pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 155 to 156.

Technical data
134

Technical data
CR 5 with 4-pole motor, 60 Hz
CR Pump type Motor P2 [kW] B1 CR 5-2 CR 5-3 CR 5-4 CR 5-5 CR 5-6 CR 5-7 CR 5-8 CR 5-9 CR 5-10 CR 5-11 CR 5-12 CR 5-13 CR 5-14 CR 5-15 CR 5-16 CR 5-18 CR 5-20 CR 5-22 CR 5-24 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.37 0.37 0.37 0.37 0.55 0.55 0.55 0.55 0.75 0.75 0.75 279 312 339 382 409 436 463 490 521 548 575 602 629 656 683 767 821 875 929 Dimension [mm] DIN flange B1+B2 470 503 530 573 600 627 654 681 712 739 766 793 860 887 914 998 1052 1106 1160 Oval flange B1 254 287 314 357 384 411 438 465 496 523 550 577 604 631 658 B1+B2 445 478 505 548 575 602 629 656 687 714 741 768 835 862 889 D1 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 D2 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109

CR pumps with 4-pole motor 60 Hz

Net weight [kg] D3 105 105 105 105 105 105 105 105 105 105 105 105 120 120 120 120 120 120 120 DIN flange 22 27 27 35 36 37 37 38 44 44 45 56 56 57 57 73 74 75 78 Oval flange 18 22 23 31 32 32 33 33 39 40 40 52 52 52 53 -

Note: 4-pole CR 5 pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 155 to 156.

CR 10 with 4-pole motor, 60 Hz


CR Pump type Motor P2 [kW] B1 CR 10-1 CR 10-2 CR 10-3 CR 10-4 CR 10-5 CR 10-6 CR 10-7 CR 10-8 CR 10-9 CR 10-10 CR 10-12 CR 10-14 CR 10-16 CR 10-17 0.25 0.25 0.25 0.37 0.37 0.55 0.55 0.75 0.75 0.75 1.1 1.1 1.5 1.5 347 363 393 428 458 488 550 580 610 640 700 837 897 957 Dimension [mm] DIN flange B1+B2 538 554 584 619 649 719 781 811 841 871 981 1118 1178 1238 Oval flange B1 347 363 393 428 458 488 550 580 610 640 B1+B2 538 554 584 619 649 719 781 811 841 871 D1 141 141 141 141 141 141 141 141 141 141 178 178 178 178 D2 109 109 109 109 109 109 109 109 109 109 110 110 110 110 D3 105 105 105 105 105 120 120 120 120 120 135 135 135 135 Net weight [kg] DIN flange 35 44 46 52 53 64 86 87 88 91 89 122 129 131 Oval flange 32 42 43 49 50 61 83 84 85 88 -

Note: 4-pole CR 10 pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 155 to 156.

135

Technical data

Technical data
CR 15 with 4-pole motor, 60 Hz
CR Pump type Motor P2 [kW] B1 CR 15-1 CR 15-2 CR 15-3 CR 15-4 CR 15-5 CR 15-6 CR 15-7 CR 15-8 CR 15-9 CR 15-10 CR 15-12 0.25 0.37 0.55 0.75 1.1 1.1 1.5 1.5 2.2 2.2 2.2 415 420 465 542 587 709 754 799 844 889 979 Dimension [mm] DIN flange B1+B2 606 611 696 773 868 990 1035 1080 1179 1224 1314 Oval flange B1 415 420 465 542 587 B1+B2 606 611 696 773 868 D1 141 141 141 141 178 178 178 178 198 198 198 D2 109 109 109 109 110 110 110 110 120 120 120

CR pumps with 4-pole motor 60 Hz

Net weight [kg] D3 105 105 120 120 135 135 135 135 160 160 160 DIN flange 48 54 65 87 87 119 125 127 143 145 178 Oval flange 47 53 64 86 86 -

Note: 4-pole CR 15 pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 155 to 156.

CR 20 with 4-pole motor, 60 Hz


CR Pump type Motor P2 [kW] B1 CR 20-1 CR 20-2 CR 20-3 CR 20-4 CR 20-5 CR 20-6 CR 20-7 CR 20-8 CR 20-10 0.25 0.55 0.75 1.1 1.5 1.5 2.2 2.2 3.0 415 420 497 542 664 709 754 799 889 Dimension [mm] DIN flange B1+B2 606 651 728 823 945 990 1089 1134 1224 Oval flange B1 415 420 497 542 664 B1+B2 606 651 728 823 945 D1 141 141 141 178 178 178 198 198 198 D2 109 109 109 110 110 110 120 120 120 D3 105 120 120 135 135 135 160 160 160 Net weight [kg] DIN flange 49 64 86 85 122 124 139 141 174 Oval flange 48 63 85 84 121 -

Note: 4-pole CR 20 pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 155 to 156.

Technical data
136

Technical data
CR 32 with 4-pole motor, 60 Hz
CR Pump type Motor P2 [kW] B1 CR 32-1-1 CR 32-1 CR 32-2-2 CR 32-2-1 CR 32-2 CR 32-3-2 CR 32-3 CR 32-4-2 CR 32-4 CR 32-5-2 CR 32-5 CR 32-6-2 CR 32-6 CR 32-7-2 CR 32-7 CR 32-8-2 CR 32-8 CR 32-9-2 CR 32-9 CR 32-10-2 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.2 2.2 2.2 2.2 2.2 3.0 3.0 3.0 3.0 4.0 4.0 4.0 505 505 575 575 575 755 755 825 825 895 895 965 965 1035 1035 1105 1105 1175 1175 1245 Dimension [mm] DIN flange B1+B2 786 786 856 856 856 1036 1036 1106 1160 1230 1230 1300 1300 1370 1370 1440 1440 1547 1547 1617 Oval flange B1 B1+B2 D1 178 178 178 178 178 178 178 178 198 198 198 198 198 198 198 198 198 220 220 220 D2 110 110 110 110 110 110 110 110 120 120 120 120 120 120 120 120 120 134 134 134

CR pumps with 4-pole motor 60 Hz

Net weight [kg] D3 135 135 135 135 135 135 135 135 160 160 160 160 160 160 160 160 160 160 160 160 DIN flange 62 66 98 98 100 144 144 152 166 169 199 202 202 235 235 304 304 308 308 311 Oval flange -

Note: 4-pole CR 32 pumps are also available as CRN pumps with PJE connection. For information about electrical data, see pages 155 to 156.

CR 45 with 4-pole motor, 60 Hz


CR Pump type Motor P2 [kW] B1 CR 45-1-1 CR 45-1 CR 45-2-2 CR 45-2-1 CR 45-2 CR 45-3-2 CR 45-3-1 CR 45-3 CR 45-4-2 CR 45-4-1 CR 45-4 CR 45-5-2 CR 45-5-1 CR 45-5 CR 45-6-2 CR 45-6-1 CR 45-6 CR 45-7-2 CR 45-7-1 CR 45-7 1.5 1.5 1.5 1.5 2.2 2.2 2.2 2.2 3.0 3.0 3.0 4.0 4.0 4.0 4.0 5.5 5.5 5.5 5.5 5.5 559 559 749 749 749 829 829 829 909 909 909 989 989 989 1069 1069 1069 1149 1149 1149 Dimension [mm] DIN flange B1+B2 840 840 1030 1030 1084 1164 1164 1164 1244 1244 1244 1361 1361 1361 1441 1448 1448 1528 1528 1528 Oval flange B1 B1+B2 D1 178 178 178 178 198 198 198 198 198 198 198 220 220 220 220 260 260 260 260 260 D2 110 110 110 110 120 120 120 120 120 120 120 134 134 134 134 159 159 159 159 159 D3 135 135 135 135 160 160 160 160 160 160 160 160 160 160 160 300 300 300 300 300 Net weight [kg] DIN flange 102 104 145 145 159 193 193 193 229 295 295 301 301 301 326 335 335 414 414 414 Oval flange -

Note: 4-pole CR 45 pumps are also available as CRN pumps with PJE connection. For information about electrical data, see pages 155 to 156.

137

Technical data

Technical data
CR 64 with 4-pole motor, 60 Hz
CR Pump type Motor P2 [kW] B1 CR 64-1-1 CR 64-1 CR 64-2-2 CR 64-2-1 CR 64-2 CR 64-3-2 CR 64-3-1 CR 64-3 CR 64-4-2 CR 64-4-1 CR 64-4 CR 64-5-2 1.5 1.5 2.2 2.2 3.0 3.0 4.0 4.0 4.0 5.5 5.5 5.5 561 671 754 754 754 836 836 836 919 919 919 1001 Dimension [mm] DIN flange B1+B2 842 952 1089 1089 1089 1171 1208 1208 1291 1298 1298 1380 Oval flange B1 B1+B2 D1 178 178 198 198 198 198 220 220 220 260 260 260 D2 110 110 120 120 120 120 134 134 134 159 159 159

CR pumps with 4-pole motor 60 Hz

Net weight [kg] D3 135 135 160 160 160 160 160 160 160 300 300 300 DIN flange 104 139 163 193 223 234 301 301 331 340 404 409 Oval flange -

Note: 4-pole CR 64 pumps are also available as CRN pumps with PJE connection. For information about electrical data, see pages 155 to 156.

CR 90 with 4-pole motor, 60 Hz


CR Pump type Motor P2 [kW] B1 CR 90-1-1 CR 90-1 CR 90-2-2 CR 90-2-1 CR 90-2 CR 90-3-2 CR 90-3-1 CR 90-3 CR 90-4-2 1.5 2.2 3.0 3.0 4.0 4.0 5.5 5.5 5.5 681 681 773 773 773 865 865 865 957 Dimension [mm] DIN flange B1+B2 962 1016 1108 1108 1145 1237 1244 1244 1336 Oval flange B1 B1+B2 D1 178 198 198 198 220 220 260 260 260 D2 110 120 120 120 134 134 159 159 159 D3 135 160 160 160 160 160 300 300 300 Net weight [kg] DIN flange 144 158 193 224 291 331 340 404 419 Oval flange -

Note: 4-pole pumps are also available as CRN pumps with PJE connection. For information about electrical data, see pages 155 to 156.

CR 120 with 4-pole motor, 60 Hz


CR Pump type Motor P2 [kW] B1 CR 120-1 CR 120-2-2 CR 120-2-1 CR 120-2 CR 120-3-1 CR 120-3 CR 120-4-1 CR 120-5-2 2.2 3.0 4.0 5.5 5.5 7.5 11.0 11.0 834 990 990 990 1145 1175 1331 1486 Dimension [mm] DIN flange B1+B2 1169 1325 1362 1369 1524 1604 1802 1957 Oval flange B1 B1+B2 D1 198 198 220 260 260 260 314 314 D2 120 120 134 159 159 159 204 204 D3 270 270 270 300 300 300 350 350 Net weight [kg] DIN flange 119 134 143 148 153 168 209 218 Oval flange -

Note: 4-pole CR 120 pumps are also available as CRN pumps with PJEconnection. For information about electrical data, see pages 155 to 156.

Technical data
138

Technical data
CR 150 with 4-pole motor, 60 Hz
CR Pump type Motor P2 [kW] B1 CR 150-1-1 CR 150-1 CR 150-2-2 CR 150-2-1 CR 150-2 CR 150-3-2 CR 150-3 CR 150-4-2 2.2 3.0 4.0 5.5 5.5 7.5 11.0 11.0 834 834 990 990 990 1175 1175 1331 Dimension [mm] DIN flange B1+B2 1169 1169 1362 1369 1369 1604 1646 1802 Oval flange B1 B1+B2 D1 198 198 220 260 260 260 314 314 D2 120 120 134 159 159 159 204 204

CR pumps with 4-pole motor 60 Hz

Net weight [kg] D3 270 270 270 300 300 300 350 350 DIN flange 119 125 144 149 149 168 199 208 Oval flange -

Note: 4-pole CR 150 pumps are also available as CRN pumps with PJE connection. For information about electrical data, see pages 155 to 156.

139

Technical data

Technical data
CRN pumps with magnetic drive
Dimensional drawings

CRN pumps with magnetic drive (MAGdrive) 50 and 60 Hz

CRN 1 CRN 3

CRN 5

CRN 10

Technical data

140

TM03 9140 3407

TM03 9138 3407

TM03 9137 3407

Technical data

CRN pumps with magnetic drive (MAGdrive) 50 and 60 Hz

CRN 15 CRN 20

D2 D1

B2

CRN 32
G 1/2

D3

PN16-25-40/DN65 B1 G 1/2 8 x 18

170 226 320

30

4 x 14
74 240 298

D2 D1

B2

CRN 45
G 1/2

D3

PN16-25-40/DN80 B1 G 1/2 8 x 18

140

120 160 200

G 1/2

TM01 1752 2203

TM01 1750 2203

105

107 145 185

G 1/2

TM03 9139 3407

Technical data

190 251 365

80 266 331

45

4 x 14

141

Technical data
D2 D1

CRN pumps with magnetic drive (MAGdrive) 50 and 60 Hz

F (DIN) PN25-40/DN100 8 x 22 B2

CRN 64
G 1/2

D3

45

100

266 331 F (DIN) PN16/DN100

B1

G 1/2

8 x 18

150 190 235 4 x 14

G 1/2

140

190 251 365


D2 D1

45

100

266 331

F (DIN) PN25-40/DN100 8 x 22 B2

CRN 90
G 1/2

D3

45

100

280 348 F (DIN) PN16/DN100

B1

G 1/2

8 x 18

156 190 235

G 1/2

150 180 220

G 1/2

4 x 14

4 x 14

140

199 261 380

45

100

280 348

Technical data

142

156 180 235

G 1/2

4 x 14

TM02 1570 2203

TM01 1754 0904

Technical data
CRN pumps with magnetic drive
Dimensions and weights CRN 1s - MAGdrive, 50 Hz

CRN pumps with magnetic drive (MAGdrive) 50 Hz

CRN MAGdrive Pump type Motor P2 [kW] B1 CRN 1s-2 CRN 1s-3 CRN 1s-4 CRN 1s-5 CRN 1s-6 CRN 1s-7 CRN 1s-8 CRN 1s-9 CRN 1s-10 CRN 1s-11 CRN 1s-12 CRN 1s-13 CRN 1s-15 CRN 1s-17 CRN 1s-19 CRN 1s-21 CRN 1s-23 CRN 1s-25 CRN 1s-27 CRN 1s-30 CRN 1s-33 CRN 1s-36 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.55 0.55 0.55 0.55 0.55 0.75 0.75 0.75 1.1 1.1 1.1 1.1 1.1 367 367 385 403 421 439 457 475 493 511 529 547 583 619 655 697 733 769 805 859 913 967 Dimension [mm] DIN flange B2 191 191 191 191 191 191 191 191 191 191 191 191 191 191 231 231 231 231 231 231 231 231 B1+B2 558 558 576 594 612 630 648 666 684 702 720 738 774 810 886 928 964 1000 1036 1090 1144 1198 B1 342 342 360 378 396 414 432 450 468 486 504 522 558 594 630 672 708 744 780 834 888 942 PJE B2 191 191 191 191 191 191 191 191 191 191 191 191 191 191 231 231 231 231 231 231 231 231 B1+B2 533 533 551 569 587 605 623 641 659 677 695 713 749 785 861 903 939 975 1011 1065 1119 1173 D1 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 D2 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 D3 Net weight [kg] DIN flange 24 25 25 25 26 26 27 27 27 29 29 30 30 31 33 35 35 39 39 40 41 43 PJE 20 20 21 21 22 22 22 23 23 24 25 25 26 27 28 30 31 35 35 36 37 38

For information about electrical data, see pages 155 to 156.

143

Technical data

Technical data
CRN 1 - MAGdrive, 50 Hz

CRN pumps with magnetic drive (MAGdrive) 50 Hz

CRN MAGdrive Pump type Motor P2 [kW] B1 CRN 1-2 CRN 1-3 CRN 1-4 CRN 1-5 CRN 1-6 CRN 1-7 CRN 1-8 CRN 1-9 CRN 1-10 CRN 1-11 CRN 1-12 CRN 1-13 CRN 1-15 CRN 1-17 CRN 1-19 CRN 1-21 CRN 1-23 CRN 1-25 CRN 1-27 CRN 1-30 CRN 1-33 CRN 1-36 0.37 0.37 0.37 0.37 0.37 0.55 0.55 0.55 0.55 0.75 0.75 0.75 0.75 1.1 1.1 1.1 1.1 1.5 1.5 1.5 2.2 2.2 367 367 385 403 421 439 457 475 493 511 535 553 589 625 661 697 733 785 821 875 929 983 Dimension [mm] DIN flange B2 191 191 191 191 191 191 191 191 191 231 231 231 231 231 231 231 231 281 281 281 321 321 B1+B2 558 558 576 594 612 630 648 666 684 742 766 784 820 856 892 928 964 1066 1102 1156 1250 1304 B1 342 342 360 378 396 414 432 450 468 486 510 528 564 600 636 672 708 760 796 850 904 958 PJE B2 191 191 191 191 191 191 191 191 191 231 231 231 231 231 231 231 231 281 281 281 321 321 B1+B2 533 533 551 569 587 605 623 641 659 717 741 759 795 831 867 903 939 1041 1077 1131 1225 1279 D1 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 178 178 178 178 178 D2 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 110 110 110 110 110 D3 Net weight [kg] DIN flange 24 25 25 25 26 27 27 28 28 29 31 32 32 35 36 37 38 46 47 48 50 51 PJE 20 20 21 21 22 23 23 24 24 25 27 27 28 31 32 33 34 42 43 44 46 47

For information about electrical data, see pages 155 to 156.

Technical data
144

Technical data
CRN 3 - MAGdrive, 50 Hz

CRN pumps with magnetic drive (MAGdrive) 50 Hz

CRN MAGdrive Pump type Motor P2 [kW] B1 CRN 3-2 CRN 3-3 CRN 3-4 CRN 3-5 CRN 3-6 CRN 3-7 CRN 3-8 CRN 3-9 CRN 3-10 CRN 3-11 CRN 3-12 CRN 3-13 CRN 3-15 CRN 3-17 CRN 3-19 CRN 3-21 CRN 3-23 CRN 3-25 CRN 3-27 CRN 3-29 CRN 3-31 CRN 3-33 CRN 3-36 0.37 0.37 0.37 0.55 0.55 0.55 0.75 0.75 0.75 1.1 1.1 1.1 1.1 1.5 1.5 2.2 2.2 2.2 2.2 2.2 3 3 3 367 367 385 403 421 439 463 481 499 517 535 553 589 641 677 713 749 785 821 857 897 933 987 Dimension [mm] DIN flange B2 191 191 191 191 191 191 231 231 231 231 231 231 231 281 281 321 321 321 321 321 335 335 335 B1+B2 558 558 576 594 612 630 694 712 730 748 766 784 820 922 958 1034 1070 1106 1142 1178 1232 1268 1322 B1 342 342 360 378 396 414 438 456 474 492 510 528 564 616 652 688 724 760 796 832 872 908 962 PJE B2 191 191 191 191 191 191 231 231 231 231 231 231 231 281 281 321 321 321 321 321 335 335 335 B1+B2 533 533 551 569 587 605 669 687 705 723 741 759 795 897 933 1009 1045 1081 1117 1153 1207 1243 1297 D1 141 141 141 141 141 141 141 141 141 141 141 141 141 178 178 178 178 178 178 178 198 198 198 D2 109 109 109 109 109 109 109 109 109 109 109 109 109 110 110 110 110 110 110 110 120 120 120 D3 Net weight [kg] DIN flange 24 25 25 26 27 27 30 30 30 33 33 34 35 43 44 45 46 47 47 48 53 54 55 PJE 20 20 21 22 22 23 25 26 26 29 29 30 30 39 39 41 42 42 43 44 49 50 51

For information about electrical data, see pages 155 to 156.

CRN 5 - MAGdrive, 50 Hz
CRN MAGdrive Pump type Motor P2 [kW] B1 CRN 5-2 CRN 5-3 CRN 5-4 CRN 5-5 CRN 5-6 CRN 5-7 CRN 5-8 CRN 5-9 CRN 5-10 CRN 5-11 CRN 5-12 CRN 5-13 CRN 5-14 CRN 5-15 CRN 5-16 CRN 5-18 CRN 5-20 CRN 5-22 CRN 5-24 CRN 5-26 CRN 5-29 CRN 5-32 CRN 5-36 0.37 0.55 0.75 0.75 1.1 1.1 1.1 1.5 1.5 2.2 2.2 2.2 2.2 2.2 3 3 3 4 4 4 5.5 5.5 5.5 367 394 421 454 481 508 535 578 605 632 659 686 713 740 767 825 879 933 987 1041 1122 1254 1362 Dimension [mm] DIN flange B2 191 191 231 231 231 231 231 281 281 321 321 321 321 321 335 335 335 372 372 372 391 391 391 B1+B2 558 585 652 685 712 739 766 859 886 953 980 1007 1034 1061 1102 1160 1214 1305 1359 1413 1513 1645 1753 B1 342 369 396 429 456 483 510 553 580 607 634 661 688 715 742 800 854 908 962 1016 1097 1229 1337 PJE B2 191 191 231 231 231 231 231 281 281 321 321 321 321 321 335 335 335 372 372 372 391 391 391 B1+B2 533 560 627 660 687 714 741 834 861 928 955 982 1009 1036 1077 1135 1189 1280 1334 1388 1488 1620 1728 D1 141 141 141 141 141 141 141 178 178 178 178 178 178 178 178 198 198 220 220 220 220 220 220 D2 109 109 109 109 109 109 109 110 110 110 110 110 110 110 110 120 120 134 134 134 134 134 134 D3 300 300 300 Net weight [kg] DIN flange 26 27 28 30 33 33 34 41 42 43 43 44 45 45 49 51 52 65 67 68 77 92 94 PJE 21 23 24 26 29 29 30 37 37 39 39 40 40 41 44 47 48 61 62 64 72 88 90

Technical data

For information about electrical data, see pages 155 to 156.

145

Technical data
CRN 10 - MAGdrive, 50 Hz

CRN pumps with magnetic drive (MAGdrive) 50 Hz

CRN MAGdrive Pump type Motor P2 [kW] B1 CRN 10-1 CRN 10-2 CRN 10-3 CRN 10-4 CRN 10-5 CRN 10-6 CRN 10-7 CRN 10-8 CRN 10-9 CRN 10-10 CRN 10-12 CRN 10-14 CRN 10-16 CRN 10-18 CRN 10-20 CRN 10-22 0.55 0.75 1.1 1.5 2.2 2.2 3 3 4 4 5.5 5.5 5.5 7.5 7.5 11 443 447 477 523 553 583 618 648 678 708 768 860 920 980 1040 1100 Dimension [mm] DIN flange B2 191 231 231 281 321 321 335 335 372 372 391 391 391 379 379 471 B1+B2 634 678 708 804 874 904 953 983 1050 1080 1159 1251 1311 1359 1419 1571 B1 443 447 477 523 553 583 618 648 678 708 768 860 920 980 1040 1100 PJE B2 191 231 231 281 321 321 335 335 372 372 391 391 391 379 379 471 B1+B2 634 678 708 804 874 904 953 983 1050 1080 1159 1251 1311 1359 1419 1571 D1 141 141 141 178 178 178 198 198 198 220 220 220 220 260 260 314 D2 109 109 109 110 110 110 120 120 120 134 134 134 134 159 159 204 D3 300 300 300 300 300 350 Net weight [kg] DIN flange 40 41 45 53 55 56 61 62 74 74 76 99 101 121 123 191 PJE 36 38 41 49 51 52 57 59 71 71 73 95 97 118 120 157

For information about electrical data, see pages 155 to 156.

CRN 15 - MAGdrive, 50 Hz
CRN MAGdrive Pump type Motor P2 [kW] B1 CRN 15-1 CRN 15-2 CRN 15-3 CRN 15-4 CRN 15-5 CRN 15-6 CRN 15-7 CRN 15-8 CRN 15-9 CRN 15-10 CRN 15-12 CRN 15-14 CRN 15-17 1.1 2.2 3 4 5.5 5.5 7.5 7.5 7.5 11 11 15 15 490 505 555 600 645 722 767 812 857 979 1069 1159 1294 Dimension [mm] DIN flange B2 231 321 335 372 391 391 379 379 379 471 471 471 471 B1+B2 721 826 890 972 1036 1113 1146 1191 1236 1450 1540 1630 1765 B1 490 505 555 600 645 722 767 812 857 979 1069 1159 1294 PJE B2 231 321 335 372 391 391 379 379 379 471 471 471 471 B1+B2 721 826 890 972 1036 1113 1146 1191 1236 1450 1540 1630 1765 D1 141 178 198 220 220 220 260 260 260 314 314 314 314 D2 109 110 120 134 134 134 159 159 159 204 204 204 204 D3 300 300 300 300 300 350 350 350 350 Net weight [kg] DIN flange 45 53 59 71 73 95 111 115 117 141 143 165 184 PJE 40 48 54 67 68 90 107 110 112 136 139 161 180

For information about electrical data, see pages 155 to 156.

Technical data
146

Technical data
CRN 20 - MAGdrive, 50 Hz

CRN pumps with magnetic drive (MAGdrive) 50 Hz

CRN MAGdrive Pump type Motor P2 [kW] B1 CRN 20-1 CRN 20-2 CRN 20-3 CRN 20-4 CRN 20-5 CRN 20-6 CRN 20-7 CRN 20-8 CRN 20-10 CRN 20-12 CRN 20-14 CRN 20-17 1.1 2.2 4 5.5 5.5 7.5 7.5 11 11 15 15 18.5 487 503 553 630 675 720 765 887 977 1067 1157 1292 Dimension [mm] DIN flange B2 231 321 372 391 391 379 379 471 471 471 471 515 B1+B2 718 824 925 1021 1066 1099 1144 1358 1448 1538 1628 1807 B1 487 503 553 630 675 720 765 887 977 1067 1157 1292 PJE B2 231 321 372 391 391 379 379 471 471 471 471 515 B1+B2 718 824 925 1021 1066 1099 1144 1358 1448 1538 1628 1807 D1 141 178 220 220 220 260 260 314 314 314 314 314 D2 109 110 134 134 134 159 159 204 204 204 204 204 D3 300 300 300 300 350 350 350 350 350 Net weight [kg] DIN flange 46 54 71 93 94 113 114 137 141 176 179 206 PJE 41 49 66 88 89 108 110 132 136 171 175 202

For information about electrical data, see pages 155 to 156.

CRN 32 - MAGdrive, 50 Hz
CRN MAGdrive Pump type Motor P2 [kW] B1 CRN 32-1-1 CRN 32-1 CRN 32-2-2 CRN 32-2 CRN 32-3-2 CRN 32-3 CRN 32-4-2 CRN 32-4 CRN 32-5-2 CRN 32-5 CRN 32-6-2 CRN 32-6 CRN 32-7-2 CRN 32-7 CRN 32-8-2 CRN 32-8 CRN 32-9-2 CRN 32-9 CRN 32-10-2 CRN 32-10 CRN 32-11-2 CRN 32-11 CRN 32-12-2 CRN 32-12 1.5 2.2 3 4 5.5 5.5 7.5 7.5 11 11 11 11 15 15 15 15 18.5 18.5 18.5 18.5 22 22 22 22 505 505 575 575 666 666 715 715 895 895 965 965 1035 1035 1105 1105 1175 1175 1245 1245 1315 1315 1385 1385 Dimension [mm] DIN flange B2 281 321 335 372 391 391 379 379 471 471 471 471 471 471 471 471 515 515 515 515 541 541 541 541 B1+B2 786 826 910 947 1057 1057 1094 1094 1366 1366 1436 1436 1506 1506 1576 1576 1690 1690 1760 1760 1856 1856 1926 1926 B1 PJE B2 B1+B2 D1 178 178 198 220 220 220 260 260 314 314 314 314 314 314 314 314 314 314 314 314 314 314 314 314 D2 110 110 120 134 134 134 159 159 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 D3 270 270 270 270 300 300 300 300 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 Net weight [kg] DIN flange 69 69 76 87 102 102 121 121 148 148 151 151 193 193 199 199 199 199 202 202 276 176 280 280 PJE -

For information about electrical data, see pages 155 to 156. Note: CRN 32 pumps are also available with PJE connection.

147

Technical data

Technical data
CRN 45 - MAGdrive, 50 Hz

CRN pumps with magnetic drive (MAGdrive) 50 Hz

CRN MAGdrive Pump type Motor P2 [kW] B1 CRN 45-1-1 CRN 45-1 CRN 45-2-2 CRN 45-2 CRN 45-3-2 CRN 45-3 CRN 45-4-2 CRN 45-4 CRN 45-5-2 CRN 45-5 CRN 45-6-2 CRN 45-6 3 4 5.5 7.5 11 11 15 15 18.5 18.5 22 22 559 559 660 639 829 829 909 909 989 989 1069 1069 Dimension [mm] DIN flange B2 335 372 391 379 471 471 471 471 515 515 541 541 B1+B2 894 931 1051 1018 1300 1300 1380 1380 1504 1504 1610 1610 B1 PJE B2 B1+B2 D1 198 220 220 260 314 314 314 314 314 314 314 314 D2 120 134 134 159 204 204 204 204 204 204 204 204 D3 270 270 300 300 350 350 350 350 350 350 350 350 Net weight [kg] DIN flange 81 92 107 121 153 153 185 195 195 195 273 273 PJE -

For information about electrical data, see pages 155 to 156. Note: CRN 45 pumps are also available with PJE connection.

CRN 64 - MAGdrive, 50 Hz
CRN MAGdrive Pump type Motor P2 [kW] B1 CRN 64-1-1 CRN 64-1 CRN 64-2-2 CRN 64-2-1 CRN 64-2 CRN 64-3-2 CRN 64-3-1 CRN 64-3 CRN 64-4-2 CRN 64-4-1 4 7.5 11 11 15 15 18.5 18.5 22 22 561 561 644 754 754 836 836 836 919 919 Dimension [mm] DIN flange B2 372 379 471 471 471 471 515 515 541 541 B1+B2 933 940 1115 1225 1225 1307 1351 1351 1460 1460 B1 PJE B2 B1+B2 D1 220 260 314 314 314 314 314 314 314 314 D2 134 159 204 204 204 204 204 204 204 204 D3 270 300 350 350 350 350 350 350 350 350 Net weight [kg] DIN flange 95 118 152 152 170 193 191 191 266 266 PJE -

For information about electrical data, see pages 155 to 156. Note: CRN 64 pumps are also available with PJE connection.

CRN 90 - MAGdrive, 50 Hz
CRN MAGdrive Pump type Motor P2 [kW] B1 CRN 90-1-1 CRN 90-1 CRN 90-2-2 CRN 90-2 CRN 90-3-2 5.5 7.5 15 18.5 18.5 592 571 773 773 865 Dimension [mm] DIN flange B2 391 379 471 515 515 B1+B2 983 950 1244 1288 1380 B1 PJE B2 B1+B2 D1 220 260 314 314 314 D2 134 159 204 204 204 D3 300 300 350 350 350 Net weight [kg] DIN flange 111 125 177 192 197 PJE -

For information about electrical data, see pages 155 to 156. Note: CRN 90 pumps are also available with PJE connection.

Technical data
148

Technical data
CRN 1s - MAGdrive, 60 Hz

CRN pumps with magnetic drive (MAGdrive) 60 Hz

CRN MAGdrive Pump type Motor P2 [kW] B1 CRN1s-2 CRN1s-3 CRN1s-4 CRN1s-5 CRN1s-6 CRN1s-7 CRN1s-8 CRN1s-9 CRN1s-10 CRN1s-11 CRN1s-12 CRN1s-13 CRN1s-15 CRN1s-17 CRN1s-19 CRN1s-21 CRN1s-23 CRN1s-25 CRN1s-27 0.37 0.37 0.37 0.37 0.55 0.55 0.55 0.75 0.75 0.75 0.75 0.75 1.1 1.1 1.1 1.5 1.5 1.5 2.2 367 367 385 403 421 439 457 475 493 511 529 547 583 619 655 713 749 785 821 Dimension [mm] DIN flange B2 191 191 191 191 191 191 191 191 191 191 191 191 191 191 231 281 281 281 321 B1+B2 558 558 576 594 612 630 648 666 684 702 720 738 774 810 886 994 1030 1066 1142 B1 342 342 360 378 396 414 432 450 468 486 504 522 558 594 630 688 724 760 796 PJE B2 191 191 191 191 191 191 191 191 191 191 191 191 191 191 231 281 281 281 321 B1+B2 533 533 551 569 587 605 623 641 659 677 695 713 749 785 861 969 1005 1041 1117 D1 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 178 178 178 178 D2 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 110 110 110 110 D3 Net weight [kg] DIN flange 24 25 25 25 27 27 28 29 29 30 30 31 40 40 41 44 44 44 45 PJE 20 20 21 21 23 23 23 25 25 25 26 26 36 36 36 39 40 40 41

For information about electrical data, see pages 155 to 156.

CRN 1 - MAGdrive, 60 Hz
CRN MAGdrive Pump type Motor P2 [kW] B1 CRN1-2 CRN1-3 CRN1-4 CRN1-5 CRN1-6 CRN1-7 CRN1-8 CRN1-9 CRN1-10 CRN1-11 CRN1-12 CRN1-13 CRN1-15 CRN1-17 CRN1-19 CRN1-21 CRN1-23 CRN1-25 CRN1-27 0.37 0.37 0.55 0.55 0.75 0.75 0.75 1.1 1.1 1.1 1.1 1.5 1.5 1.5 2.2 2.2 2.2 3 3 367 367 385 403 421 439 457 475 493 511 535 569 605 641 677 713 749 790 826 Dimension [mm] DIN flange B2 191 191 191 191 191 191 191 191 191 231 231 281 281 281 321 321 321 335 335 B1+B2 558 558 576 594 612 630 648 666 684 742 766 850 886 922 998 1034 1070 1125 1161 B1 342 342 360 378 396 414 432 450 468 486 510 544 580 616 652 688 724 765 801 PJE B2 191 191 191 191 191 191 191 191 191 231 231 281 281 281 321 321 321 335 335 B1+B2 533 533 551 569 587 605 623 641 659 717 741 825 861 897 973 1009 1045 1100 1136 D1 141 141 141 141 141 141 141 141 141 141 141 178 178 178 178 178 178 198 198 D2 109 109 109 109 109 109 109 109 109 109 109 110 110 110 110 110 110 120 120 D3 Net weight [kg] DIN flange 24 25 26 26 28 28 28 37 37 37 39 41 41 42 42 43 44 54 55 PJE 20 20 22 22 24 24 24 33 33 33 35 36 37 38 38 39 40 50 51

For information about electrical data, see pages 155 to 156.

149

Technical data

Technical data
CRN 3 - MAGdrive, 60 Hz

CRN pumps with magnetic drive (MAGdrive) 60 Hz

CRN MAGdrive Pump type Motor P2 [kW] B1 CRN3-2 CRN3-3 CRN3-4 CRN3-5 CRN3-6 CRN3-7 CRN3-8 CRN3-9 CRN3-10 CRN3-11 CRN3-12 CRN3-13 CRN3-15 CRN3-17 CRN3-19 CRN3-21 CRN3-23 CRN3-25 0.37 0.55 0.75 0.75 1.1 1.1 1.1 1.5 1.5 1.5 2.2 2.2 2.2 3 3 3 4 4 367 367 385 403 421 439 463 497 515 533 551 569 605 646 682 718 754 790 Dimension [mm] DIN flange B2 191 191 191 191 191 191 231 281 281 281 321 321 321 335 335 335 372 372 B1+B2 558 558 576 594 612 630 694 778 796 814 872 890 926 981 1017 1053 1126 1162 B1 342 342 360 378 396 414 438 472 490 508 526 544 580 621 657 693 729 765 PJE B2 191 191 191 191 191 191 231 281 281 281 321 321 321 335 335 335 372 372 B1+B2 533 533 551 569 587 605 669 753 771 789 847 865 901 956 992 1028 1101 1137 D1 141 141 141 141 141 141 141 178 178 178 178 178 178 198 198 198 198 198 D2 109 109 109 109 109 109 109 110 110 110 110 110 110 120 120 120 120 120 D3 Net weight [kg] DIN flange 24 26 27 27 36 36 38 39 39 39 39 40 41 51 52 52 69 70 PJE 20 21 23 23 31 32 33 35 35 35 35 36 36 47 47 48 65 65

For information about electrical data, see pages 155 to 156.

CRN 5 - MAGdrive, 60 Hz
CRN MAGdrive Pump type Motor P2 [kW] B1 CRN5-2 CRN5-3 CRN5-4 CRN5-5 CRN5-6 CRN5-7 CRN5-8 CRN5-9 CRN5-10 CRN5-11 CRN5-12 CRN5-13 CRN5-14 CRN5-15 CRN5-16 CRN5-18 CRN5-20 0.75 1.1 1.1 1.5 2.2 2.2 2.2 3 3 3 4 4 4 4 5.5 5.5 5.5 367 394 421 470 497 524 551 583 610 637 664 691 719 745 817 875 929 Dimension [mm] DIN flange B2 191 191 231 281 321 321 321 335 335 335 372 372 372 372 391 391 391 B1+B2 558 585 652 751 818 845 872 918 945 972 1036 1063 1089.6 1116.6 1208.4 1266.4 1320.4 B1 342 369 396 445 472 499 526 558 585 612 639 666 694 720 792 850 904 PJE B2 191 191 231 281 321 321 321 335 335 335 372 372 372 372 391 391 391 B1+B2 533 560 627 726 793 820 847 893 920 947 1011 1038 1064.6 1091.6 1183.4 1241.4 1295.4 D1 141 141 141 178 178 178 178 198 198 198 198 198 198 198 220 220 220 D2 109 109 109 110 110 110 110 120 120 120 120 120 120 120 134 134 134 D3 300 300 300 Net weight [kg] DIN flange 27 35 35 39 39 39 40 49 50 50 65 66 67 67 76 76 77 PJE 22 31 31 35 35 35 36 45 45 46 61 62 62 62 71 72 73

For information about electrical data, see pages 155 to 156.

Technical data
150

Technical data
CRN 10 - MAGdrive, 60 Hz

CRN pumps with magnetic drive (MAGdrive) 60 Hz

CRN MAGdrive Pump type Motor P2 [kW] B1 CRN10-1 CRN10-2 CRN10-3 CRN10-4 CRN10-5 CRN10-6 CRN10-7 CRN10-8 CRN10-9 CRN10-10 CRN10-12 CRN10-14 CRN10-16 0.75 1.5 2.2 3 4 4 5.5 5.5 7.5 7.5 7.5 11 11 443 463 493 528 558 588 635 665 695 725 785 902 962 Dimension [mm] DIN flange B2 191 281 321 335 372 372 391 391 379 379 379 471 471 B1+B2 634 743.5 813.5 863 930 1026 1026 1056 1074 1104 1164 1373 1433 B1 443 463 493 528 558 588 635 665 695 725 785 902 962 PJE B2 191 281 321 335 372 372 391 391 379 379 379 471 471 B1+B2 634 743.5 813.5 863 930 1026 1026 1056 1074 1104 1164 1373 1433 D1 141 178 178 198 198 198 220 220 260 260 260 314 314 D2 109 110 110 120 120 120 134 134 159 159 159 204 204 D3 300 300 300 300 300 350 350 Net weight [kg] DIN flange 41 50 51 61 78 79 86 87 97 97 97 152 154 PJE 37 47 47 57 74 75 82 84 94 94 94 148 150

For information about electrical data, see pages 155 to 156.

CRN 15 - MAGdrive, 60 Hz
CRN MAGdrive Pump type Motor P2 [kW] B1 CRN15-1 CRN15-2 CRN15-3 CRN15-4 CRN15-5 CRN15-6 CRN15-7 CRN15-8 CRN15-9 CRN15-10 CRN15-12 1.5 3 5.5 7.5 7.5 11 11 15 15 15 18.5 506 510 572 617 645 764 809 854 899 979 1069 Dimension [mm] DIN flange B2 281 335 391 379 379 471 471 471 471 471 515 B1+B2 786.5 845 963 996 1024 1235 1280 1325 1370 1450 1584 B1 506 510 572 617 645 764 809 854 899 979 1069 PJE B2 281 335 391 379 379 471 471 471 471 471 515 B1+B2 786.5 845 963 996 1024 1235 1280 1325 1370 1450 1584 D1 178 198 220 260 260 314 314 314 314 314 314 D2 110 120 134 159 159 204 204 204 204 204 204 D3 300 300 300 350 350 350 350 350 350 Net weight [kg] DIN flange 46 56 75 87 87 148 152 173 175 175 169 PJE 41 51 70 83 83 143 148 168 170 170 164

For information about electrical data, see pages 155 to 156.

CRN 20 - MAGdrive, 60 Hz
CRN MAGdrive Pump type Motor P2 [kW] B1 CRN20-1 CRN20-2 CRN20-3 CRN20-4 CRN20-5 CRN20-6 CRN20-7 CRN20-8 2.2 4 7.5 11 11 15 15 18.5 503 508 570 740 785 830 875 887 Dimension [mm] DIN flange B2 321 372 379 471 471 471 471 515 B1+B2 823.5 880 949 1211 1256 1301 1346 1402 B1 503 508 570 740 785 830 875 887 PJE B2 321 372 379 471 471 471 471 515 B1+B2 823.5 880 949 1211 1256 1301 1346 1402 D1 178 198 260 314 314 314 314 314 D2 110 120 159 204 204 204 204 204 D3 300 350 350 350 350 350 Net weight [kg] DIN flange 52 76 87 146 147 170 171 163 PJE 47 71 82 141 142 165 167 159

For information about electrical data, see pages 155 to 156.

151

Technical data

Technical data
CRN 32 - MAGdrive, 60 Hz

CRN pumps with magnetic drive (MAGdrive) 60 Hz

CRN MAGdrive Pump type Motor P2 [kW] B1 CRN32-1-1 CRN32-1 CRN32-2-2 CRN 32-2-1 CRN32-2 CRN32-3-2 CRN32-3 CRN32-4-2 CRN32-4 CRN32-5-2 CRN32-5 CRN32-6-2 CRN32-6 CRN32-7-2 CRN32-7 3 5.5 5.5 5.5 7.5 11 11 15 15 15 18.5 18.5 22 22 22 505 505 575 575 575 690 690 757 757 895 895 965 965 1035 1035 Dimension [mm] DIN flange B2 335 391 391 391 379 471 471 471 471 471 515 515 541 541 541 B1+B2 840 896 966 966 954 1161 1161 1228 1228 1366 1410 1480 1506 1576 1576 B1 PJE B2 B1+B2 D1 198 220 220 220 260 314 314 314 314 314 314 314 314 314 314 D2 120 134 134 134 159 204 204 204 204 204 204 204 204 204 204 D3 300 300 300 300 350 350 350 350 350 350 350 350 350 350 Net weight [kg] DIN flange 77 96 101 101 108 155 155 179 179 180 172 172 238 266 266 PJE -

For information about electrical data, see pages 155 to 156. Note: CRN 32 pumps are also available with PJE connection.

CRN 45 - MAGdrive, 60 Hz
CRN MAGdrive Pump type Motor P2 [kW] B1 CRN45-1-1 CRN45-1 CRN45-2-2 CRN45-2-1 CRN45-2 CRN45-3-2 CRN45-3-1 CRN45-3 CRN45-4-2 5.5 7.5 11 15 15 18.5 18.5 18.5 22 559 559 770 749 749 829 829 829 909 Dimension [mm] DIN flange B2 391 379 471 471 471 515 515 515 541 B1+B2 950 938 1241 1220 1220 1344 1344 1344 1450 B1 PJE B2 B1+B2 D1 220 260 314 314 314 314 314 314 314 D2 134 159 204 204 204 204 204 204 204 D3 300 300 350 350 350 350 350 350 350 Net weight [kg] DIN flange 106 116 160 178 178 169 169 169 268 PJE -

For information about electrical data, see pages 155 to 156. Note: CRN 45 pumps are also available with PJE connection.

CRN 64 - MAGdrive, 60 Hz
CRN MAGdrive Pump type Motor P2 [kW] B1 CRN64-1-1 CRN64-1 CRN64-2-2 CRN64-2-1 CRN64-2 CRN64-3-2 7.5 11 15 18.5 22 22 561 671 644 754 754 836 Dimension [mm] DIN flange B2 379 471 471 515 541 541 B1+B2 940 1142 1115 1269 1295 1377 B1 PJE B2 B1+B2 D1 260 314 314 314 314 314 D2 159 204 204 204 204 204 D3 300 350 350 350 350 350 Net weight [kg] DIN flange 111 158 173 168 243 166 PJE -

For information about electrical data, see pages 155 to 156. Note: CRN 64 pumps are also available with PJE connection.

Technical data
152

Technical data
CRN 90 - MAGdrive, 60 Hz
CRN MAGdrive Pump type Motor P2 [kW] B1 CRN90-1-1 CRN90-1 CRN90-2-2 11 15 22 702 681 773 Dimension [mm] DIN flange B2 471 471 541 B1+B2 1173 1152 1314 B1 PJE B2 B1+B2 D1 314 314 314 D2 204 204 204 D3 350 350 350 Net weight [kg] DIN flange 164 182 250 PJE -

For information about electrical data, see pages 155 to 156. Note: CRN 90 pumps are also available with PJE connection.

153

Technical data

154

Motor data
Standard 2-pole motors for CR, CRI, CRN, 50 Hz
Motor P2 [kW] 0.37 0.55 0.75 1.1 1.5 2.2 3.0 4.0 5.5 7.5 11 15 18.5 22 30 37 45 55 75 Frame size 71 71 80 80 90 90 100 112 132 132 160 160 160 180 200 200 225 250 280 Standard voltage [V] 220-240/380-415Y 220-240/380-415Y 220-240/380-415Y 220-240/380-415Y 220-240/380-415Y 380-415 380-415 380-415 380-415 380-415/660-690Y I 1/1 [A] 1.7/1.0 2.5/1.4 3.3/1.9 4.5/2.6 5.5/3.2 4.5-4.5 6.3-6.3 8.0-8.0 11.2-11.2 14.8-13.6/8.5-8.1 Cos 1/1 0.80-0.70 0.80-0.70 0.81-0.71 0.84-0.76 0.87-0.82 0.89-0.87 0.87-0.82 0.88-0.84 0.88-0.84 [%] 78.5 80.0 81.0 82.8 85.5 87.5 87.5 89.0 90.0 Istart 8.5-9.2/4.9-5.3 12-13/6.9-7.5 19.1-20.5/11.0-11.8 28.5-31.5/16.3-17.9 46.3-50.7/26.8-29.3 37.8-42.3 52.9-58.0 89.6-98.4 120-131 115-124/66.3-73.7 140-153/80.5-90.5 188-203/107-122 249-272/142-163 311-343/179-203 371/214 461/266 562/325 632/367 896-832/518-481

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Speed [min1] 2850-2880 2830-2850 2840-2870 2820-2860 2890-2910 2890-2910 2900-2920 2910-2930 2910-2930 2920-2940 2920-2940 2920-2940 2930-2940

MG

380-415/660-690Y 21.2-19.6/12.2-11.6 0.90-0.88 90.0-88.0 380-415/660-690Y 28.5-26.0/16.2-15.6 0.91-0.90 91.0-92.3 380-415/660-690Y 35.0-32.0/20.0-19.2 0.91-0.90 91.6-92.6 380-415/660-690Y 41.5-38.5/23.8-22.8 0.91-0.89 91.9-92.8 380-415/660-690Y 380-415/660-690Y 380-415/660-690Y 380-415/660-690Y 380-415/660-690Y 53.0/30.5 64.0/37.0 77.0/44.5 93.0/54.0 128/74.0 0.88-0.88 0.89-0.89 0.89-0.89 0.90-0.90 0.89-0.89 93.5 94.0 95.0 95.5 95.0

Siemens 2960 2960 2965 2975 2975


TM03 1710 2805

Note: CR pumps with motors from 1.1 to 75 kW are efficiency class 1 motors

Standard 4-pole motors for CR, CRI, CRN, 50 Hz


Motor P2 [kW] 0.25 0.37 0.55 0.75 1.1 1.5 2.2 3.0 4.0 5.5 7.5 11.0 15.0 Frame size 71 71 80 80 90 90 100 100 112 132 132 160 160 Standard voltage [V] 220-240/380-415Y 220-240/380-415Y 220-240/380-415Y 220-240/380-415Y 220-240/380-415Y 220-240/380-415Y 220-240/380-415Y 380-415 380-415 380-415/660-690Y 380-415/660-690Y 380-415/660-690Y 380-415/660-690Y I 1/1 [A] 1.48/0.85 1.90/1.10 2.60/1.50 3.30/1.90 5.00/2.90 6.40/3.70 9.20/5.30 7.40 8.90 11.2-10.4/6.50-6.25 15.2-14.0/8.70-8.40 21.6-20.4/12.4-12.0 29.0-28.0/16.8-16.4 Cos 1/1 0.75-0.65 0.77-0.67 0.79-0.70 0.79-0.70 0.78-0.71 0.80-0.74 0.79-0.76 0.79-0.69 0.82-0.76 0.86-0.84 0.87-0.85 0.88-0.84 0.87-0.84 [%] 71-72 71 77 78 78 80 83.5 85 86.5-87 89.0-90.0 89.5-90.5 91.0-92.0 92.6-92.0 Speed [min1] 1400-1420 1400-1420 1390-1410 1390-1410 1440-1445 1440-1450 1440-1450 1440-1450 1440-1450 1440-1450 1460-1470 1460-1470
TM03 1711 2805

MG

1450-1455

Note: CR pumps with motors from 1.1 to 15 kW are efficiency class 1 motors

TM03 1711 2805

0.89-0.88 89.5-90.5

2920-2930

155

Motor data
Standard 2-pole motors for CR, CRI, CRN, 60 Hz
Motor Frame P2 size [kW] 0.37 0.55 0.75 1.1 1.5 2.2 3.0 4.0 5.5 7.5 11 15 18.5 22 30 37 45 55 75 71 71 80 80 90 90 100 112 132 132 160 160 160 180 200 200 225 250 280 Standard voltage [V] 220-255/380-440Y 220-255/380-440Y 220-255/380-440Y 220-255/380-440Y 220-277/380-480Y 380-480 380-480 380-480 380-480 380-480/660-690Y I 1/1 [A] 1.5-1.4/0.9-0.8 2.2-2.1/1.3-1.2 2.9-2.7/1.7-1.6 4.2-3.9/2.5-2.2 5.4-4.7/3.1-2.7 4.5-3.7 6.2-5.7 7.8-6.8 10.8-9.5 14.4-12.0/8.3-8.1 Cos 1/1 [%] Istart 8.3-9.4/4.8-4.9 10.8-12.3/6.3-7.2 17.1-20.0/9.9-11.5 25.6-30.4/14.9-17.5 41.7-49.4/24.2-28.4 34.7-40.7 49.6-62.2 79.6-102 108-138 97.9-126/56.4-85.1 123-153/70.8-103 168-203/96.3-141 214-272/123-186 273-348/157-237 358-360/252-240 442-448/254-307 543-559/312-378 621-632/358-424 871-864/501-584

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Speed [min1] 3410-3470 3390-3460 3400-3470 3390-3460 3470-3530 3470-3530 3430-3530 3510-3540 3510-3540 3500-3550 3500-3550 3500-3550 3500-3550

MG

0.85-0.76 79.0-80.0 0.85-0.76 81.5-83.0 0.86-0.78 83.0-85.0 0.88-0.82 82.0-84.5 0.90-0.81 84.0-85.0 0.91-0.85 84.0-87.0 0.89-0.84 84.0-87.5 0.90-0.82 88.0-89.5 0.90-0.82 89.0-89.0 0.91-0.85 90.0-91.5

380-480/660-690Y 21.2-17.2/12.2-11.6 0.91-0.87 90.0-92.5 380-480/660-690Y 29.0-22.8/16.6-15.8 0.92-0.89 90.0-92.5 380-480/660-690Y 35.0-28.0/20.2-19.2 0.92-0.89 90.5-93.0 380-480/660-690Y 42.0-33.5/24.2-22.8 0.92-0.89 90.0-92.5 380-480/660-690Y 55.0-45.0/31.5-30.0 0.90-0.86 92.5-93.5 380-480/660-690Y 67.0-54.0/38.5-37.0 0.90-0.87 93.0-94.0 380-480/660-690Y 81.0-65.0/46.5-44.0 0.90-0.87 94.5-95.0 380-480/660-690Y 97.0-79.0/56.0-53.0 0.91-0.88 94.5-95.0 380-480/660-690Y 134-108/77.0-73.0 0.90-0.87 95.0-95.5

Siemens 3540-3565 3540-3565


TM03 1710 2805

3545-3570 3565-3580 3565-3580

Note: CR pumps with motors from 1.1 to 75 kW are efficiency class 1 motors

Standard 4-pole motors for CR, CRI, CRN, 60 Hz


Motor P2 [kW] 0.25 0.37 0.55 0.75 1.1 1.5 2.2 3.0 4.0 5.5 7.5 11.0 15.0 Frame size 71 71 80 80 90 90 100 100 112 132 132 160 160 Standard voltage [V] 220-255/380-440Y 220-255/380-440Y 220-255/380-440Y 220-255/380-440Y 220-277/380-480Y 220-277/380-480Y 220-277/380-480Y 380-480 380-480 380-480/660-690Y 380-480/660-690Y 380-480/660-690Y 380-480/660-690Y I 1/1 [A] 1.21/0.70 1.72/0.99 2.40/1.40 3.10/1.80 4.75-4.50/2.75-2.60 6.30-5.70/3.65-3.30 9.00-7.80/5.20-4.50 7.10-6.75 8.60-7.70 10.8-9.30/6.25-6.10 14.4-12.4/8.30-8.20 21.0-17.8/12.0-11.8 29.0-24.2/16.6-16.4 Cos 1/1 0.80-0.69 0.82-0.72 0.83-0.75 0.84-0.76 0.82-0.67 0.83-0.73 0.80-0.70 0.80-0.70 0.85-0.73 0.89-0.81 0.90-0.82 0.90-0.83 0.89-0.83 [%] 69-69 73-74 77-80 77-81 78-80 79-81 83-85 84-85 87-89 89.5-91.0 90.5-92.0 91.4-93.0 91.7-93.2 Speed [min1] 1680-1720 1680-1720 1660-1710 1660-1710 1720-1750 1720-1750 1720-1750 1720-1750 1750-1770 1750-1770 1750-1770 1750-1770
TM03 1711 2805

MG

1740-1755

Note: CR pumps with motors from 1.1 to 15 kW are efficiency class 1 motors

156

TM03 1711 2805

3480-3510

Pumped liquids
Pumped liquids
Thin, non-flammable liquids, not containing solid particles or fibres. The liquid must not chemically attack the pump materials. When pumping liquids with a density and/or viscosity higher than that of water, oversize motors must be used, if required. Whether a pump is suitable for a particular liquid depends on a number of factors of which the most important are the chloride content, pH value, temperature and content of chemicals, oils, etc. Please note that aggressive liquids (e.g. seawater and some acids) may attack or dissolve the protective oxide film of the stainless steel and thus cause corrosion. The CR(E), CRI(E), CRN(E) pump types are suitable for the following liquids: CR(E), CRI(E) Non-corrosive liquids. For liquid transfer, circulation and pressure boosting of cold or hot clean water. CRN(E) Industrial liquids. In systems where all parts in contact with the liquid must be made of high-grade stainless steel. CRT(E) Saline liquids. Hypochlorites. Acids. For saline or chloride-containing liquids such as seawater or oxidizing agents such as hypochlorites, CRT(E) pumps of titanium are available. See separate data booklet on CRT(E).
Pumped liquid Acetic acid CH3COOH Acetone CH3COCH3 Alkaline degreasing agent Ammonium bicarbonate NH4HCO3 Ammonium hydroxide NH4OH Aviation fuel Benzoic acid C6H5COOH Boiler water Calcareous water Calcium acetate (as coolant with inhibitor) Ca(CH3COO)2 Calcium hydroxide Ca(OH)2 Chloride-containing water Note 1, F D, F E 1, 3, 4, F H F D, E E F Liquid concentration, liquid temperature 5 %, +20 C 100 %, +20 C 20 %, +30 C 20 %, +40 C 100 %, +20 C 0.5 %, +20 C <+120 C +120 C - +180 C < +90 C 30 %, +50 C Saturated solution, +50 C < +30 C, max. 500 ppm

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

List of pumped liquids


A number of typical liquids are listed below. Other pump versions may be applicable, but those stated in the list are considered to be the best choices. The table is intended as a general guide only and cannot replace actual testing of the pumped liquids and pump materials under specific working conditions. The list should, however, be applied with some caution as factors such as those below may affect the chemical resistance of a specific pump version: concentration of the pumped liquid, liquid temperature pressure. Safety precautions must be made when pumping dangerous liquids. For further information about pumped liquids, contact Grundfos. Notes
D E F H 1 2 3 4 Often with additives. Density and/or viscosity differ from that of water. Allow for this when calculating motor output and pump performance. Pump selection depends on many factors. Contact Grundfos. Risk of crystallization/precipitation in shaft seal. The pumped liquid highly flammable. The pumped liquid is combustible. Insoluble in water. Low self-ignition point.

CR(E), CRI(E) HQQE HQQE HQBV HQQE HQQE HQQE HQQE -

CRN(E) HQQE HQQE HQQE HQQV HQQE

157

Pumped liquids
Liquid concentration, liquid temperature 1 %, +20 C 5 %, +40 C +120 C +120 C 10 %, +50 C 100 %, +80 C 100 %, +20 C < +120 C 100 %, +20 C 50 %, +50 C 5 %, +20 C 50 %, +50 C 100 %, +100 C 100 %, +100 C 100 %, +20 C 10 %, +20 C 100 %, +20 C 100 %, +20 C 100 %, +80 C 100 %, +80 C 1 %, +20 C < +100 C 100 %, +80 C 1 %, +20 C < +100 C 100 %, +80 C 100 %, +20 C 20 %, +20 C 100 %, +20 C 50 %, +90 C 20 %, +50 C 30 %, +50 C 20 %, +50 C 5 %, +20 C 100 %, +80 C 0.1 %, +20 C 100 % 10 %, +60 C 30 %, < +5 C, pH>8 20 %, +50 C

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Pumped liquid Chromic acid H2CrO4 Citric acid HOC(CH2CO2H)2COOH Completely desalinated water (demineralized water) Condensate Copper sulphate CuSO4 Corn oil Diesel oil Domestic hot water (potable water) Ethanol (ethyl alcohol) C2H5OH Ethylene glycol HOCH2CH2OH Formic acid HCOOH Glycerine (glycerol) OHCH2CH(OH)CH2OH Hydraulic oil (mineral) Hydraulic oil (synthetic) Isopropyl alcohol CH3CHOHCH3 Lactic acid CH3CH(OH)COOH Linoleic acid C17H31COOH Methanol (methyl alcohol) CH3OH Motor oil Naphthalene C10H8 Nitric acid HNO3 Oil-containing water Olive oil Oxalic acid (COOH)2 Ozone-containing water (O3) Peanut oil Petrol Phosphoric acid H3PO4 Propanol C3H7OH Propylene glycol CH3CH(OH)CH2OH Potassium carbonate K2CO3 Potassium formate (as coolant with inhibitor) KOOCH Potassium hydroxide KOH Potassium permanganate KMnO4 Rape seed oil Salicylic acid C6H4(OH)COOH Silicone oil Sodium bicarbonate NaHCO3 Sodium chloride (as coolant) NaCl Sodium hydroxide NaOH

Note H H E D, E, 3 2, 3, 4, F 1, F D, E D, E E, 2, 3 E, 2, 3 1, F E, H E, 3 1, F E, 2, 3 E, H F D, E, 3 H D, E, 3 1, 3, 4, F E 1, F D, E E D, E E D, E, 3 H E, 3 E D, E E

CR(E), CRI(E) HQQE HQQV HQBV HQQE HQQE HQQE HQQE HQQV HQQV HQQE HQQV HQQE HQQV HQQV HQQV HQQV HQQV HQBV HQQE HQQE HQQE HQQE HQQV HQQV HQQE -

CRN(E) HQQV HQQE HQQE HQQE HQQE HQQV HQQE HQQE HQQE HQQE HQQE HQQE HQQE HQQE HQQE

158

Pumped liquids
Liquid concentration, liquid temperature 0.1 %, +20 C 10 %, +60 C 10 %, +60 C 10 %, +60 C < +120 C 100 %, +80 C 1 %, +20 C 1 %, +20 C Approx. 2 ppm free chlorine (Cl2)

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

Pumped liquid Sodium hypochlorite NaOCl Sodium nitrate NaNO3 Sodium phosphate Na3PO4 Sodium sulphate Na2SO4 Softened water Soya oil Sulphuric acid H2SO4 Sulphurous acid H2SO3 Unsalted swimming-pool water

Note F E E, H E, H D, E, 3 F -

CR(E), CRI(E) HQQV HQQE

CRN(E) HQQV HQQE HQQE HQQE HQQE HQQV HQQE -

159

Further product documentation


WebCAPS

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

WebCAPS is a Web-based Computer Aided Product Selection program available on www.grundfos.com. WebCAPS contains detailed information on more than 185,000 Grundfos products in more than 20 languages. In WebCAPS, all information is divided into 6 sections: Catalogue Literature Service Sizing Replacement CAD drawings.

Catalogue This section is based on fields of application and pump types, and contains technical data curves (QH, Eta, P1, P2, etc.) which can be adapted to the density and viscosity of the pumped liquid and show the number of pumps in operation product photos dimensional drawings wiring diagrams quotation texts, etc.

Literature In this section you can access all the latest documents of a given pump, such as data booklets installation and operating instructions service documentation, such as Service kit catalogue and Service kit instructions quick guides product brochures, etc.

Service This section contains an easy-to-use interactive service catalogue. Here you can find and identify service parts of both existing and discontinued Grundfos pumps. Furthermore, this section contains service videos showing you how to replace service parts.

160

Further product documentation


Sizing
0 1

CR, CRI, CRN, CRT, CRE, CRIE, CRNE, CRTE

This section is based on different fields of application and installation examples, and gives easy step-by-step instructions in how to select the most suitable and efficient pump for your installation carry out advanced calculations based on energy consumption, payback periods, load profiles, life cycle costs, etc. analyse your selected pump via the built-in life cycle cost tool determine the flow velocity in wastewater applications, etc.

Replacement In this section you find a guide to selecting and comparing replacement data of an installed pump in order to replace the pump with a more efficient Grundfos pump. The section contains replacement data of a wide range of pumps produced by other manufacturers than Grundfos. Based on an easy step-by-step guide, you can compare Grundfos pumps with the one you have installed on your site. When you have specified the installed pump, the guide will suggest a number of Grundfos pumps which can improve both comfort and efficiency.

CAD drawings In this section it is possible to download 2-dimensional (2D) and 3-dimensional (3D) CAD drawings of most Grundfos pumps. These formats are available in WebCAPS: 2-dimensional drawings: .dxf, wireframe drawings .dwg, wireframe drawings. 3-dimensional drawings: .dwg, wireframe drawings (without surfaces) .stp, solid drawings (with surfaces) .eprt, E-drawings.

WinCAPS
WinCAPS is a Windows-based Computer Aided Product Selection program containing detailed information on more than 185,000 Grundfos products in more than 20 languages. The program contains the same features and functions as WebCAPS, but is an ideal solution if no Internet connection is available. WinCAPS is available on CD-ROM and updated once a year.
Fig. 87 WinCAPS CD-ROM

161

162

163

Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence

96486346 0509
Repl. 96486346 0907

GB

Subject to alterations.

GRUNDFOS A/S . DK-8850 Bjerringbro . Denmark Telephone: +45 87 50 14 00 www.grundfos.com