Beruflich Dokumente
Kultur Dokumente
For the 1st time connection please follow the procedure as seen on the
browser
Installation Guidelines for Til Applet
Software Download
Select the delivery file and press the choose delivery file button
Click on OK
First Commissioning
BTS Re-connection
Go to BTS
BTS Re-connection
Visually check that the information contained in the TIL boards screen
complies with the BTS configuration:
Using information displayed at the bottom of the screen (refer to Figure 35):
Check the Software Reference
Check the BTS type
Verify that the Serial Number is the same as the Serial Number given in
section 2 of
the report sheet.
If abnormal check occurred, contact the site coordinator before going on.
BTS.
be YES
If protection module for PCM is installed then Protection Module value must
BTS.
As eg below new_451282.til
BTS Re-connection
ICCM-EMOAM>BTS
--------------------------------------------- Packaging ------------------------------------------------iBTS : Indoor (600mm)
|
|
|
|
|
|
|
|
|
|
|
|
|
Logical slot
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
Physical slot
| _ | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | __ | 10 |
|
|
|
|
|
|
|
|
|
|
|
|
|
------------------------------------------- Configuration ----------------------------------------------Radio Mode ............................ Unknown (STR1)
EXT ATM CONN .......................... NOT CREATED
NODEBCP ASU ........................... DISCONNECTED (connected)
OMCB ................................. DISCONNECTED (connected)
MIBState .............................. NOT BUILD (BUILD)
Flip-Flop ............................. Not actif
Version ............................... UNB04D220A0
DDM master ............................ None (No DLU)
---------------------------------------- Hardware Snapshot ---------------------------------------------Slot | Type
| HwRel |
Serial Number
|
PEC
|
Module Name
5 |
iCCM |
01 |
NNTM75061N1T |
NTUM25CS |
MOD:ICCM2BOARD
--------------------------------------------------------------------------------------------------------3 |
iTRM |
01 |
NNTM75061LAQ |
NTUM17AF |
MOD:ITRM2100
7 | iCEM128 |
01 |
NNTM75061LSK |
NTUM00DG |
MOD:ICEM2128
8 | iCEM128 |
01 |
NNTM75061HS0 |
NTUM00DG |
MOD:ICEM2128
--------------------------------------------------------------------------------------------------------12 |
GPSAM |
01 |
NNTM75061K7V |
NTUM24AF |
MOD:GPSAM
--------------------------------------------------------------------------------------------------------0 |
DDM |
01 |
FORM03008924 |
NTU747AF |
MOD:DDM32100UMTS
1 |
DDM |
01 |
FORM03008726 |
NTU747AF |
MOD:DDM32100UMTS
2 |
DDM |
01 |
FORM03009020 |
NTU747AF |
MOD:DDM32100UMTS
------------------------------------ Slaves State management -------------------------------------------Slot | Type
| Soft
|
Hard
|
Admin
| ConfStat | OpState |
UTime
| L3 Connected
3 |
iTRM | Soft ok | Disable | Unlocked | Config ok | Disable | XXXXXXXXX |
L3 complete
7 | iCEM128 | Soft ok |
Enable | Unlocked | Config ok | Enable |
Synchro |
L3 complete
8 | iCEM128 | Soft ok |
Enable | Unlocked | Config ok | Enable |
Synchro |
L3 complete
--------------------------------- OAM CallP and ATM Configuration --------------------------------------Slot | Type
| Declared To Callp |
CCP AAL5
|
AAL2 (0)
|
AAL2 (1)
|
AtmHandle
3 |
iTRM |
Not Declared |
None
|
None
|
None
|
0x1017
7 | iCEM128 |
Not Declared |
0xffffffff
|
0xffffffff
|
0xffffffff
|
0x1018
8 | iCEM128 |
Not Declared |
0xffffffff
|
0xffffffff
|
0xffffffff
|
0x1019
---------------------------------------- RF LINK Configuration -----------------------------------------Slot | Type
|
LHP reserve
|
FwdCemToAdder
|
FwdAdderToTrm
|
RvCemToTrm
3 |
iTRM |
YES | XXXXXXXXXXXXXXXXXXXXXXX |
NO |
NO
7 | iCEM128 |
YES |
NO | XXXXXXXXXXXXXXXXXXXXX |
NO
8 | iCEM128 |
YES |
NO | XXXXXXXXXXXXXXXXXXXXX |
NO
------------------------------------------- CCP informations -------------------------------------------Slot | Type
|
CCP Allocated
|
CCP State
|
CCP Status
7 | iCEM128 | XXXXXXXXXXXXXXXXXX |
DISABLE |
NOT ALLOC
8 | iCEM128 | XXXXXXXXXXXXXXXXXX |
DISABLE |
NOT ALLOC
------------------------------------------- CEM BBUs Load Configuration --------------------------------Slot | Type
|
BBU0
|
BBU1
|
|
requested
|
current
|
requested
|
current
7 | iCEM128 |
UNKNOWN |
DCH |
UNKNOWN |
DCH
8 | iCEM128 |
UNKNOWN |
DCH |
UNKNOWN |
DCH
--------------------------------------------------------------------------------------------------------Cell Mapping not available in not built BTS !
RF Cabling not available in not built BTS !
+-------------------------------------------------------------------------------+
|
Tx Propagation Delay
|
+-------------------------------------------------------------------------------+
| Local Cell Id | Ccm | Trm | Pa | Tx Splitter | Ddm | RFoutput to Antenna |
+-------------------------------------------------------------------------------+
+-------------------------------------------------------------------------------+
|
Rx Propagation Delay
|
+-------------------------------------------------------------------------------+
| Local Cell Id |
Ccm
|
Trm
|
Ddm
|
Antenna To RFinput
|
+-------------------------------------------------------------------------------+
+-------------------------------------------------------------------------------+
|
Tx and Rx Total Propagation Delay
|
+-------------------------------------------------------------------------------+
| Local Cell Id |
Dl Main
|
Dl Div | Ul Main/Div |
Local Cell State |
+-------------------------------------------------------------------------------+
+-------------------------------------------------------------------------------+
|
Cell Delay Propagation Send to Cem State
|
+-------------------------------------------------------------------------------+
|
Cem Slot
|
Local Cell Id
|
CellDelaySentToCem
|
+-------------------------------------------------------------------------------+
+-------------------------------------------------------------------------------+
ICCM-EMOAM>
________________________________________________________________________________________________