Step 1
Set DAE2 Enclosure Address(es)
Loop 0
Loop 1
Fibre Channel copper cables for connecting the DAE2 to SPE or DPE2
storage processors, or for connecting multiple DAE2s to each other (2 per DAE2)
EXP Loop 1
PRI Loop 1
Loop 0
If you will use EMC Navisphere Manager to manage the DAE2 with
an EMC CX-Series storage system The Configuration and Planning Guide appropriate for your system. These manuals are available on Powerlink and the appropriate Hardware Documentation CD. EMC Navisphere Manager Version 6.X Administrators Guide (P/N 069001125) available on the EMC Navisphere Manager 6.X Documentation CD (P/N 068090604).
0 +
EA0/Loop 0 BE 0 BE 0 BE 1 BE 1
EMC2720s
The illustration below shows an example storage-system configuration with four pairs of redundant DAE2 loops: A0/B0, A1/B1, A2/B2, A3/B3.
LCC B
EMC2790
EA1/Loop 3
LCC A
Loop 3 EA1/Loop 2 Loop 2 EA1/Loop 1 Loop 1 EA1/Loop 0 Loop 0 EA0/Loop 3 Loop 3 EA0/Loop 2 Loop 0 Loop 1
Loop 3
Set the enclosure address (EA) on each DAE2 in a given loop to a unique number. We strongly suggest that you number enclosures consecutively. Refer also to the illustrations in Step 2. NOTE Do not configure an ATA model DAE2 as EA 0, loop 0. ATA enclosures do not support the boot and SPS requirements of the first disk array in a storage system. An integrated disk-and-processor enclosure, such as a DPE2, is always the first disk enclosure on the first loop (0,0).
Loop 2
Loop 3 Loop 2
Step 2
Set Up Fibre Channel Loops
Connect multiple DAE2s in paired loops. (A Fibre Channel loop is sometimes called a bus.) One loop connects the SP A/LCC A (right) side of the system; the SP B/LCC B loop shares disk drives with its counterpart. Cable the expansion connector (EXP) of a DAE2 to the primary connector (PRI) of the next DAE2 you want on the loop. The primary connector of the first DAE2 in the loop is reserved for the storage processor. The first configuration on the right shows two redundant DAE2 loops connected to a 2-Gigabit Disk Processor Enclosure (DPE2).
Loop 1
EMC2709S
Step 3
Connect the DAE2 to a Storage Processing Device
1. 2.
Step 5
Start DAE2s
Turn on the power for each DAE2 power supply. If the cabinet power is not already on, be sure the other devices in the system are correctly installed and ready for powerup; then a. Plug the two 240-volt ac power cables into the power outlets in your facility. We recommend connecting each power cable to a different branch circuit. You must connect both power cables to the appropriate power source. Connecting only one power source will degrade the DAE2s performance.
PRI Connector
To other FC device
EMC2312
b. Turn on the circuit breakers on each of the cabinets side power strips. The green power lights on the front of the DAE2 chassis and on each disk drive indicate that power is on; an amber chassis light indicates a fault.
Fault LED (Amber) Power LED (Green)
If you are connecting the first DAE2 in a loop to a storage processing device, such as an SPE or DPE2: 1. Plug one end of a copper cable into the primary (PRI) High Speed Serial Data Connector (HSSDC) connector on each Link Control Card (LCC) in the DAE2. Plug the other end of the cables into the appropriate connector on the storage processor device. For more information, refer to the Setup Guide or the Hardware Reference for the device.
2.
Step 4
Connect DAE2 Power Cords
Power Switch/ Cord Power Switch/ Cord
DAE2
DAE2
If an amber light on the front of a DAE2 is lit, make sure the DAE2 is correctly cabled, the enclosure addresses are correct, and the disks are completely seated. Then refer to the fault code explanations in Chapter 3 of the DAE2 Hardware Reference, available on Powerlink and the DAE2 Hardware Documentation CD. If you cannot determine any reasons for errors, contact your DAE2 service provider.
DAE2
DAE2
SPE
Copyright 2003, 2004 EMC Corporation. All rights reserved. EMC believes the information in this publication is accurate as of its publication date. However, the information is subject to change without notice.
EMC1972
1. 2.
Connect one end of an ac power cable to the power connector on each DAE2 power supply. Connect the other end to the nearest power outlet in the cabinet. For high availability, connect the power supplies to opposing side power strips so they do not share a single circuit.
THE INFORMATION IN THIS PUBLICATION IS PROVIDED AS IS. EMC CORPORATION MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WITH RESPECT TO THE INFORMATION IN THIS PUBLICATION, AND SPECIFICALLY DISCLAIMS IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Use, copying, and distribution of any EMC software described in this publication require an applicable software license.
EMC2, EMC, CLARalert, CLARiiON, Navisphere, and PowerPath are registered trademarks and Access Logix, MirrorView, SAN Copy, and SnapView are trademarks of EMC Corporation. All other trademarks mentioned herein are the property of their respective owners.
In the CX600/CX700 SPE example above, the first DAE2 is connected to a secondary power supply (SPS). In DPE2 configurations, you should not connect a DAE2 to the SPS. Refer to the relevant Setup Guide or Hardware Reference for device-specific configuration rules.