Sie sind auf Seite 1von 16

EX.

NO: DATE

SINGLE ROOM BUILDING

AIM:
Draw the plan, section and elevation of a single room building with R.C.C roofing

SPECIFICATION:
i. FOUNDATION: Depth of the foundation is 900mm. The concrete course is at base is 0.8m. While at 0.2m thick, width of first and second footing is 0.7m and 0.6m respectively. The footing for all the walls is of R.R masonry. Basement wall or plinth wall is of first wall brick work masonry of width, 400mm and length is 600mm. The damp proof course is provided all around the beneath the super structure for the thickness of 20mm ii. SUPER STRUCTURE: The wall is width of 230mm, height of selling is 3m [inner to inner]. Roof slab is 150mm long. RCC over the roof slab weathering course of 75mm laid, parapet wall is 200mm thick, 600mm height. iii. SIZE OF DOORS AND WINDOWS: Door = 1.5m 2.1m Window = 1.5m 1.2m iv. FLOORING:

Earth is filled to a depth of 400mm over which clean sand is filled for a depth of 160mm. PCC of 30mm thick is laid with smooth cement finish over with thickness of 10mm

v.

SIZE OF STEPS: Thread = 300mm Rise = 150mm

Minimum thickness of slab is 100mm

vi.

LINTEL-CUM-SUNSHADE: Lintel is provided at doors and windows thickness of lintel is 150mm. Its projects over out as a sunshade from the exterior face of the wall for 450mm and thickness of 60mm.

LINE SKETCH:

EX.NO DATE AIM:

RESIDENTIAL BUILING

Draw the plan, section, and elevation of a residential room building with RCC roofing specimen. SPECIFICATION:
i.

FOUNDATION: Depth of foundation is 900mm. The concrete course at the base is 0.8m wide and 0.2m thick width of the first and second footing is 0.7m and 0.6m. The footing for all the wall is of RR masonry

Basement wall or plinth wall is first class brick masonry of width 400mm and height 600mm Damp proof course is provided all around the beneath of the super structure for the thickness of 20mm. ii. SUPER STRUCTURE: The wall is of width 300mm. The height of ceiling is 3.6m [inner to inner] Roof slab is 150mm thick. RCC over the roof slab weathering course of 75mm is laid parapet wall is 200mm width and height is 600mm iii. SIZE OF DOORS AND WINDOWS: Door = 1.5m 2.1m Window = 1.5m 1.2m iv. FLOORING: Earth is filled to a depth of 400mm over which clean sand is filled for a depth of 160mm. PCC of 30mm thick is laid with smooth cement finish over with thickness of 10mm v. SIZE OF STEPS: Thread = 300mm Rise = 150mm

Minimum thickness of slab is 100mm

vi.

LINTEL-CUM-SUNSHADE: Lintel is provided at doors and windows thickness of lintel is 150mm. Its projects over out as a sunshade from the exterior face of the wall for 450mm and thickness 60mm.

LINE SKETCH:

EX.NO

OFFICE BUILING

DATE

AIM: Draw the plan, section, and elevation of a office building with RCC roofing. SPECIFICATION:
i.

FOUNDATION: Depth of foundation is 900mm. The concrete course at the base is0.5m wide, course at the base is 0.8m wide and 0.2m thick wide at the first and second footing is 0.7m and 0.6m. The footing for all the wall is of RR masonry Basement wall or plinth wall is first class brick masonry of width 400mm and height 600mm Damp proof course is provided all around the beneath of the super structure for the thickness of 20mm.

ii. SUPER STRUCTURE: The wall is of width 300mm. The height of ceiling is 3.6m [inner to inner] Roof slab is 150mm thick. RCC over the roof slab weathering course of 75mm is laid. Parapet wall is 200mm width and height is 600mm iii. SIZE OF DOORS AND WINDOWS: Door = 1.5m 2.1m Window = 1.5m 1.2m iv. FLOORING: Earth is filled to a depth of 400mm over which clean sand is filled for a depth of 160mm. PCC of 30mm thick is laid with smooth cement finish over with thickness of 10mm

v.

SIZE OF STEPS: Thread = 300mm Rise = 150mm

Minimum thickness of slab is 100mm

vi.

LINTEL-CUM-SUNSHADE: Lintel is provided at doors and windows thickness of lintel is 150mm. Its projects over out as a sunshade from the exterior face of the wall for 450mm and thickness 60mm.

LINE SKETCH:

EX.NO DATE

OFFICE BUILING

AIM: Draw the plan, section, and elevation of a office building with RCC roofing. SPECIFICATION:
i.

FOUNDATION: Depth of foundation is 900mm. The concrete course at the base is 0.5m wide, course at the base is 0.8m wide and 0.2m thick wide at the first and second footing is 0.7m and 0.6m. The footing for all the wall is of RR masonry Basement wall or plinth wall is first class brick masonry of width 400mm and height 600mm Damp proof course is provided all around the beneath of the super structure for the thickness of 20mm.

ii. SUPER STRUCTURE: The wall is of width 300mm. The height of ceiling is 3.6m [inner to inner] Roof slab is 150mm thick. RCC over the roof slab weathering course of 75mm is laid. Parapet wall is 200mm width and height is 600mm

iii. SIZE OF DOORS AND WINDOWS: Door = 1.5m 2.1m Window = 1.5m 1.2m iv. FLOORING: Earth is filled to a depth of 400mm over which clean sand is filled for a depth of 160mm. PCC of 30mm thick is laid with smooth cement finish over with thickness of 10mm v. SIZE OF STEPS: Thread = 300mm Rise = 150mm

vi.

LINTEL-CUM-SUNSHADE: Lintel is provided at doors and windows thickness of lintel is 150mm. Its projects over out as a sunshade from the exterior face of the wall for 450mm and thickness 60mm.

LINE SKETCH:

EX.NO DATE AIM:

NORTH LIGTH ROOF TRUSS

Draw the suitable scale the elevation of north light roof truss for a workshop SPECIFICATION: Building having clear span of 10m and rise of 2.5m roof is covered with corrugate AC sheet over a steel purlin. Any missing data may be assumed suitably. LINE SKETCH:

EX.NO DATE AIM:

SLAB

Draw the plan, and section of the slab. SPECIFICATION: A room of size having two way RCC and slab of 125mm supported to on load bearing masonry wall. Main bars of 10mm @125mm c/c alternating bend up, longer span of 8mm @150mm c/c alternatively bend up extra bars at support.

Shorter span of 12mm @ 250mm c/c 90cm long, longer span of 10mm @ 300mm c/c, 150cm long. Draw the sectional plan showing all the reinforcement in plan. XX section of slab across shorter span (along YY) YY section of slab across longer span

EX.NO DATE AIM:

A SHORT VERTICAL COLUMN

Draw the plan, and section of a short vertical column. SPECIFICATION: A square short vertical column consists of 8 bars of 16mm tied up with 8mm stirrups and 15cm pitch and supporting a doubly reinforced continuous beam designed for the following data.

Cross section of square column 4040cm2 with footing of 1.2m1.2m0.2m provided with 16mm bars at 15cm c/c both ways. Cross section of beam 40cm40cm provided with 3 numbers of 2mm dia main straight bar, 2 numbers of 22mm dia main bed bar, 3 numbers of 16mm dia main anchor bars, and 8mm stirrup bars.

EX.NO DATE

CANTILEVER BEAM

AIM: Draw the cross sectional view of a cantilever beam SPECIFICATION: A cantilever have been designed for an overhang of 3.2m projecting from a beam through a 35cm square column with the following reinforcement and cross sections.

MAIN BARS: 28mm 2 numbers for all overhang ANCHOR BAR: 16mm 2 numbers STIRRUPS BAR: 6mm width, 8cm15cm25cm c/c supports to free bar 1m1m1.2m respectively. CROSS SECTION: At support of 30cm45cm at free end of size 30cm15cm. Draw neatly the following views clearly showing all reinforcement details. a) L-section b) 2 cross section, one near the support and another near the free end

EX.NO DATE

PERSPECTIVE VIEW OF A SINGLE ROOM BUILDING

AIM:

A sketch plan of a single room building. Assume position of an observer and draw perspective view of a building retain all construction lines. SPECIFICATION: Assume suitable height and dimensions of doors and windows