Sie sind auf Seite 1von 2

Powerlink 840

G.SHDSL Series

Powerlink 840 is a digital Multi-rate and Multi-interface SHDSL modem for private 2 or 4 wire data communication lines (PDCL), with rates of 64 kbit/s to 5696 kbit/s at 2 wire or 64 kbit/s t 11392 kbit/s operating at 4 wires, always configurable in 64kbit/s steps.

MultiMux Interface
Powerlink 840 has the below listed interfaces, noting that some of them are optional items. - G.703/G.704 to 2048 kbits/s with CRC-4 error indication light. - V.35/V.36 and 64K to 11392kbits/s. - Ethernet* 10/100 half or full duplex, auto-sense, auto MDI/MDI-X, with Flow control in compliance to IEEE802.3x. - G.703/G.704 auxiliary* at 2048 kbits/s with CRC-4 error indication light. The equipment allows multiplexing of any set of available interfaces in the model. Any combination of operation speeds of the interfaces may be used, with the condition that the SHDSL line operation limits are respected.

Wetting (Sealing) Current Source*


This functionality, available in some of the Carrier Class equipment, maintains the electrical contacts clean and prevents their corrosion, through a 48V current applied to them. The equipment may be configured to function as source or sink.

DYING Gasp*
Th is ce ntra l modem fu nct iona lit y informs tha t the re was an energy shortage at th e remote modem. Thus, in case the link crashes, the network administrator may che ck directly at the console or via a management system that there was on ly a power sh orta ge an d t hat there is no need to send a technician to look at the problem.

Out of band Remote Management


This functionality provides a reduction in OPEX (Operational Expenses). The modem is equipped with a virtual terminal that allows remote access to a CPE, as for example a client router, through the remote modem console port. This gives the service provider the capability to change the remote CPE configuration and/or correct a configuration problem without having to send a technician to the client's site.

Interface Converter *
Powerlink 840 may come equipped with an interface converter circuit. On the contrary to other equipment available in the market, Powerlink 840 can convert multiple interfaces: G<=>V / G<=>E / G<=>V+E / E<=>G

Less Terminal Configuration Drop Insert


Power link 840 has a cascading function of the E1 timeslots. As a great part of the services do not consume an entire E1 frame, by using this functionality there is an economy of MUX ports connected to the E1 uplink. Used in conjunction to the Safe Adapter, even if a link or a modem crashes, the drop insert continues to function with the remaining links. Powerlink 840 makes it possible for the field technician to install the equipment without the need to carry with him a notebook or a VT100 terminal. The product allows the configuration of all its functionalities through 8-position DIP switches that make possible a vast range of configurations. Additionally, the STU-R modem may be configured so as to copy the configurations applied to the STU-C modem, extending the auto-rate functionality.

* This item is optional. Check the availability according to the specified model.

Technical Specifications
Available Models:
2F GV SHDSL 2 wires with interfaces G.703/704 and V.35/V.36 4F GV SHDSL 4 wires with interfaces G.703/704 and V.35/V.36 2F GVE SHDSL 2 wires with interfaces G.703/704, V.35/V.36 and Ethernet 10/100 4F GVE** SHDSL 4 wires with interfaces G.703/704, V.35/V.36 and Ethernet 10/100 2F GGV SHDSL with 2 interfaces G.703/704 and V.35/V.36 4F GGV** SHDSL 4 wires with 2 interfaces G.703/704 and V.35/V.36

Dimensions
177mm (Wide.), 16,8mm (High), 316,5mm. (Deep)

Weight
250 grams

Environmental Conditions of Operation


Operation emperature: 00 a 65 0C Relative Humidity: up to 95% non-condensing

Available Optionals:
T- Interface converter W- Wetting Current D- Dying Gasp
(**)The Equipments, when operating in mode 2 wires, it is has a facility of operation with 2 independents modems by card.

ABNT Standards
NBR 13414: Interconnection circuit between data terminal equipment (DTE) and data communication equipment (DCE). NBR 13415: Unbalanced interconnection circuit for data signal transmission speeds up to 100 kbit/s. NBR 13416: Balanced interconnection circuit for data signal transmission speeds up to 10 kbit/s.

Operation Types
Synchronous point-to-point 2 wire full-duplex Synchronous point-to-point 2 or 4 wire full-duplex

Operation Medium
Private Data Communication Line, PDCL, type B, in conformity to Practice TELEBRS 225-540-713.

ITU Standards
ITU-T G.703: Physical/eletrical characteristics of hierarchical digital interfaces. ITU-T G.704: Synchronous frame structures used at 1544,6312,2048,8448 e 44736 kbit/s hierarchical levels. ITU-T G.823: The control of jitter and wander within digital networks wich are based on the 2048 kbit/s hierarchy. ITU-T G.991.2: Single-pair high-speed digital subscriber line (SHDSL) transceivers. ITU-T G.994.1: Handshske procedures for Digital Subscriber Lins (DSL) transceivers.
Anatel Resolutionsl

Line Technology
Channel TC-PAM (Trellis Coded Pulse Amplitude Modulation) with 16 levels (16 -PAM). Channel TC-PAM (Trellis Coded Pulse Amplitude Modulation) with 32 levels (32 -PAM).

Test Facility
Local Analog Loop Local Digital Loop Remote Digital Loop

Configuration and Monitoring The modem configuration is carried out through straps and dips, via console (ANSI/VT1008N1) or also via Telebrs (225.540.781) management, except the digital interface physical configuration, carried our exclusively through straps. The equipment's operation and monitoring may be carried out through the console and/or management simultaneously, without interruption of one or the other. Output Impedance
135 ohms

Annex to resolution n 442-Regulation for telecommunication equipment certification for electromagnetic compatibility aspects. 0 Annex to resolution n 238-Regulation for telecommunication equipment certification for electric security aspects.

Telebrs Pratices
225-540-780:General Specifications for the compatibility of printed circuit cards, power sources, control card and sub-frame for manageable standard modems. 225-540-781: General specifications for a management network structure for standard modems. 240-600-70: Environmental conditions applicable to telecommunication equipment and auxiliary equipment. 225-540-730: General specifications for interconnection circuit between data terminal equipment (DTE) and data communication equipment (DCE).

Operation Speed From 64 kbit/s to 2048kbit/s in step s of 64kbit/s in G.703 to 2 Mbits/s. From 64kbit/s to 5696 kbit/s (2 wire) or 11392 kbit/s (4 wire) in step s of
64 kbit/s in V.35,V.36 or Ethe rnet. The same limits apply with any combina tion of inter faces operating simultane ously. .

Performance
For basic speeds over 0,40mm (26AWG) noiseless metallic pairs for error rate smaller than 10. These Values were obtained using the line simulator DSL400BR.
Sp eed s (k b it/s ) 192 256 384 512 768 1024 1536 2048 2304 3072 4480 5696 6144 8960 11392 P o w e r lin k 8 4 0 2 W R a n g e (km ) 7 ,1 6 ,5 6 ,0 5 ,6 5 ,2 4 ,8 4 ,5 4 ,1 4 ,0 3 ,5 2 ,7 2 ,0 ---------P o w e r lin k 8 4 0 4 W R a n g e (km ) 7 ,1 7 ,1 7 ,1 6 ,5 6 ,0 5 ,6 5 ,2 4 ,8 4 ,7 4 ,5 4 ,1 3 ,6 3 ,5 2 ,7 2 ,0

Power Usage
Usage depends on many factors, among them: number of active interfaces, operation at 2 or 4 wires, line rate and distance and functionalities available in the model. For the models below, we have: Interface GV- 2 Wires: 3,5W Interface GV/TWD-4 Wires: 7,4W

Digital Interfaces
V.35 standard ISO2110 Amd.1 or TELEBRS 225-540-736 V.36 standard ISO2110 Amd.1 or TELEBRS 225-540-736 G.703 2048 kbit/s with CRC-4 error indication light (75ohms and 120ohms, for selection via strap). Ethernet 10/100 Mbit/s half/fullduplex, auto sense, autoMDI/MDI-X.

IEEE Standards
IEEE 802.3:Telecommunications and information exchange between systems local and metropolitan area networks-specific requirements, part 3: carrier sense multiple access with collision detection (CSMA/CD) access method and physical layer specifications.

PARKS S.A. COMUNICAES DIGITAIS Head Office Av. Cruzeiro, 530 - Distrito Industrial - CEP 94930-615 Cachoeirinha/RS - Phone: 51 3205 2100 - Fax: 51 3205 2170 Branch Office: Al. Joaquim Eugnio de Lima, 598, Conj. 83 - CEP 01403-000 So Paulo/ SP - Phone: 11 3539 6606 Fax: 11 3539 6606