tECHNICAL DATA

POWER SUPPLY Voltage Single-phase 110 - 127VAC: 110 / 127VAC (+10%, -15%)
200 - 240VAC: 200 / 220 / 230 / 240VAC (+10%, -15%)
Frequency 50 / 60 Hz +/- 2 Hz ( 48 - 62 Hz )
Cos ϕ (Displacement Factor) > 0.98
ENCLOSURE Degree of Protection IP 20
CONTROL Electronic Power Supply Switching power supply
Control Method Sinusoidal PWM modulation (Space Vector Modulation),
Linear V/F or quadratic V/F
Switching Frequency Frequencies: from 2.5 KHZ up to 15 KHZ
Frequency Range 0 - 300 Hz
Frequency Setting Resolution Analogue Ref.: 0.1% of max. frequency and Digital ref.: 0.01 Hz (f<100Hz); 0.1Hz (f>100Hz)
Output Frequency Accuracy Analogue Ref.: 0.5% and Digital Ref.: 0.01%
Overload capacity 150% during 60 sec. every 10 min. (1.5 x In - Rated Current)
CONTROL INPUTS Analogue 1 programmable isolated Input (7 bit) 0 -10VDC; 0 - 20mA or 4 - 20mA
Digital 4 programmable isolated inputs 12 Vdc
CONTROL OUTPUTS Relay 1 programmable output, from C Contacts (NO/NC): 240Vac, 0.5A
Programming Options: Is > Ix ; Fs > Fx ; Fe > Fx ; Fs = Fe ; Run; No Fault
SAFETY Protections DC Link Overvoltage / Undervoltage
VFD Over temperature
Keypad Connection Fault
Motor Overload ( i x t )/ Output Short Circuit
CPU Error (Watchdog), External Fault
Output short-circuit
Programming Error / Self-diagnosis Error
KEYPAD (HMI) Programming Start/Stop , ( General functions programming )
Commands Start/Stop / Frequency Increases / Decreases Speed
Monitoring (reading) Output Frequency ( Hz )
DC Link Voltage ( VDC )
Speed proportional value (Ex: tt/min)
Heat sink temperature
Output Current ( Amps )
Output Voltage ( Volts )
Last Fault Messages
AMBIENT Temperature 0...122ºF (0 ... 50 °C )
Humidity 5 ... 90% non condensing
Altitude 0...3300ft (1000 m) up to (4000 m) with 10%/1000m output current de-rating
ENCLOSURE Color Opaque gray - WEG development 205E1404
CONFORMITIES Electromagnetic Compatibility EMC directive 89 / 336 / EEC
EN 61800-3
Low Voltage LVD 73/23/EEC - Low Voltge Directive / UL 508C

Variable
CONTROL Standard Keypad with 7 segment displays (LED’s)
FEATURES Password to protect VFD Programming
Fault Auto-diagnosis and automatic reset
Motor Slip compensation (V/F mode)
Manual and automatic torque boost (I x R)

Speed Drives
Linear and “S” independent acceleration ranp, two sets of ramps
Mod. 765.05/072006 - Data subject to change without previous notice.

JOG function
DC braking
Multi-Speed function (up to 8 pre programmable speeds)
Forward/Reverse Speed Selection via DI
Local/Remote Reference Selection via DI

WEG EXPORTADORA S.A. WEG EURO WEG GERMANY GmbH WEG SCANDINAVIA AB
Phone: +55 47 3372 4002 INDÚSTRIA ELÉCTRICA, S.A. Phone: +49 (2234) 9 5353-0 Phone: (46) 300 73400
Fax: +55 47 3372 4060 Phone: +351 229 477 708/700 info@weg-germany.de info@weg.se
wex-mark@weg.com.br sales@weg.com.pt wg.weg.com.br
www.weg.nrt www.weg.com.pt
WEG ITALIA S.R.L. WEG IBERIA S.A.
Phone: (39) 02 6129-3535 Phone: (34) 916 553 008
info@wegitalia.com wegiberia@wegiberia.es
WEG AUSTRALIA PTY. LTD. WEG NETHERLANDS www.wegiberia.es
Phone: +61 (3) 9765 4600 WEG Europe S.A.
Phone: +31 (0) 570-620550
WEG EUROPE S.A.
Phone: + 32 (67) 88-8420 WEG ELECTRIC MOTORS (U.K.) LTD.
Transforming energy
Fax: +61 (3) 9753 2088
sales.drives@weg.com.au info@weg-netherlands.nl info@wegeurope.be Phone : 44 (01527) 596-748 into solution
waa.weg.com.br www.weg-netherlands.nl www.wegeurope.be wegsales@wegelectricmotors.co.uk
WEG Digital CFW-10 VFD Series is an BLOCK DIAGRAM
offspring of the very successful CFW-08
Plus. In addition to a very small, easily Single-Phase Line
mounted package, simplified keypad
and bright LED readout, complete
diagnostics and fully program mable Isolated analog input
Programmable
 General enable
RFI Filter Standard Version
I/O, the CFW-10 controls three phase

Standard, Plus e Clean Version


 START/STOP

Isolated digital inputs


 On/Off
 FWD/REV

AC motors with a single phase 120V AC  Local/Remote


 Directionof
rotation

input voltage will produce three phase  Multispeed


 Jog
 2nd Ramp

230V to drive motors up to 1HD and Plus Version  Reset


 No external fault
 Electronic

single phase 230V AC will produce three Relay Output potentiometer


Standard Version

phase 230V to drive motors up to 3HP.


Increased flexibility and decreased Programmable Fs = output frequency

costs are achieved by eliminating the Standard FEATURES Fe = input frequency


Fx = set frequency
RUN Is = output current

need for a set-up transformer to operate • (V/F) Control no fault


Ix = set current

• IP20 Finger-safe Enclosure


three phase 230V AC motors when • Single-phase 110-127 input voltage up to 1HP
only single phase 115V is available. • Single-phase 200-240 input voltage up to 2HP specification table
• 150% current overload capacity
The CFW-10 is an economical solution • DSP controlled PWM output Line
VARIABLE SPEED DRIVES CFW-10 Maximum Applicable Motor Dimensions
(mm)
Weight
Voltage Model In Output Size Voltage Power (kg)
Supply
to many industrial and commercial • 2.5 - 15 kHz ajustable switching frequency (A) (V) HP kW H W D
• Four isolated programmable digital inputs
applications. 110-127
CFW100016S1112ESZ 1.6 1 0.25 0.18
132 95 121 0,9
• Programmable relay output CFW100026S1112ESZ 2.6 1 0.50 0.37
• One isolated programmable analog input CFW100040S1112ESZ 4.0 2 1.0 0.75 161 115 122 1.5
Single-phase CFW100016S2024ESZ 1.6 1 230 0.25 0.18
• Diagnostic features: Overcurrent, motor overload, drive
200-240 CFW100026S2024ESZ 2.6 1 0.50 0.37 132 95 121 0,9
over temperature, output short circuit, DC bus over and 4.0 1 1.00 0.75
CFW100040S2024ESZ
undervoltage and external fault CFW100073S1112ESZ 7.3 2 2.0 1.50 161 115 122 1.5
• Control features: Linear and “S” remp acceleration and NOTES: The maximum motor powers listed above were based on WEG II and IV-pole motors.
deceleration, local/remote control, DC braking, torque For motors with different numbers of poles (ex.: VI and VIII-poles), other voltages (ex.: 230V) and/or motors from other manufacturers,
boost, motor slip compensation, eletronic pot, preset specify the VFD through the motor rated current.
speeds, maximum and minimum adjustable frequency CODING
limits, adjustable output current limit, JOG
• Display readings: Motor speed, frequency, voltage, current, CFW10 0040 S 2024 E O 00 00 00 Z
last fault, heatsink temperature and drive status
• Ambient: 104ºF (40ºC), 3300ft (1000m) altitude, 90% 1 2 3 4 5 6 7 8 9 10
humidity, non-condensing 6 - Optionals
S = standard
O = with optionals
applicationS 1 - Variable Frequency Drive CFW-10
7- Control card
• Centrifugal pumps 2 - Output rated current: 110-127 V 200-240 V 00 = standard
0016 1,6 A 0016 1,6 A CL = clean
• Process pumps
0026 2,6 A 0026 2,6 A PL = plus (with potentiometer)
• Fans / Exhausts 0040 4,0 A 0040 4,0 A 8 - Special hardware
• Stirrers / Mixers 0073 7,3 A 00 = not provided
3 - Number of phase
• Extruding Machines S = single-phase
0100 10,0 A Hx = special hardware in version X
• Rollouttables 4 - Voltage supply 9 - Special software
• Driers 1112 = 110-127V 00 = not provided
• Rotating filters 2024 = 200-240 V Sx = special software in version X
• Cutting machines 5 - Manual Language 10 - End of code
• Conveyors P = Portuguese
E = English Ex.: CFW100040S2024ESZ
S = Spanish VFD of CFW-10 series, 4.0 A, single -phase at 200-240 VAC
and manual in English.