Abstract—Low-cost switched-reluctance-motor (SRM) drive has intensified with the prospective oncoming variable-speed
systems are actively sought for high-efficiency home appliances applications. One of the possible electrical machines in low-
and power tools. Minimizing the number of switching devices cost and variable-speed drives is the switched reluctance motor
has been in power converters that is the main method to re-
duce drive costs. Single-switch-per-phase converters have been (SRM). SRM drive system is a strong candidate for low-cost
cost effective due to the compactness of the converter package variable-speed applications, and that is mainly due to the simple
resulting in a possible reduction in their cost. However, some of construction of the machine, brushless operation, absence of
the single-switch-per-phase converters have the drawbacks that magnets, and windings on the rotor while still maintaining a
include higher losses and low-system efficiency. In order to over- relatively high torque density. This makes it potentially a very
come these shortcomings, the choice narrows down to the split
ac converter through the quantitative analysis in terms of device cost-effective and high-performance drive suitable for many
ratings, cost, switching losses, conduction losses, and converter applications. Another key to realize such low-cost motor drive
efficiency. Simulations to verify the characteristics of the converter is minimizing the number of switching devices, and one of
circuit and control feasibility are presented. The motor drive is the cost-effective solutions is using a single-switch-per-phase
realized with a novel two-phase flux-reversal-free-stator SRM and converters.
a split ac converter. The efficiency with various loads is numeri-
cally estimated and experimentally compared from the viewpoint Many cost-reducing solutions have been proposed, and al-
of subsystem and system in details. The acoustic noise with no most all have concentrated on minimizing the number of power
load and full load is also compared. The focus of this paper is switches. Single-switch-per-phase converters are most suitable
to compare the considered split ac converter to the asymmetric for inexpensive applications due to their relatively low compo-
converter through experiments and demonstrate that the split ac nent count and simplicity of the drive system as compared to
converter is the most advantageous with respect to cost, efficiency,
and acoustic noise. other well-known converters [2].
The asymmetric converter [3], shown in Fig. 1(a), is a well-
Index Terms—Acoustic noise, high efficiency, low cost, switched known converter that has two power switches and two diodes
reluctance motor (SRM).
per phase, resembling the conventional ac motor drives, and the
minimum voltage rating of each switch is the dc-link supply
I. I NTRODUCTION voltage. The motor phases are independently controlled. The
main disadvantage is the total number of the switches and the
T HE SEARCH for a lower cost and higher efficiency
brushless motor drive has intensified with the advent
of variable-speed applications in home appliances and power
diodes which reduces its cost competitiveness, and it is only
embraced in high-performance applications.
tools. While a variable-speed motor drive may become accept- The single-switch-per-phase configuration [4] is highly cost
able in some appliances, the industry predominantly moves effective because it contains only one switch per phase. Several
away from brush- and commutator-based machines for reasons topologies in this category have been developed such as bifilar,
of reliability, safety, longevity, and acoustic noise [1]. Hence, R-dump, C-dump, and split dc link. Bifilar and R-dump have
the search for a simpler and lower cost brushless motor drive the drawback of lower system efficiency under high-voltage
operation. The split dc-link converter [3], shown in Fig. 1(b),
Paper IPCSD-06-116, presented at the 2006 Industry Applications Society
has two equally split capacitors and also requires one switch
Annual Meeting, Tampa, FL, October 8–12, and approved for publication in the per phase. This converter, however, has drawbacks of having
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS by the Industrial Drives half the dc supply voltage per phase and voltage asymmetry
Committee of the IEEE Industry Applications Society. Manuscript submitted
for review January 15, 2006 and released for publication December 8, 2006.
between the two dc-link capacitors.
K. Ha, C. Lee, J. Kim, and R. Krishnan are with the Center for Rapid Transit In [1], a low-cost four-quadrant brushless motor drive, shown
Systems, The Bradley Department of Electrical and Computer Engineering, in Fig. 1(c), using a single controllable switch is presented.
Virginia Polytechnic Institute and State University, Blacksburg, VA 24061 USA
(e-mail: ksha@vt.edu; cwlee101@vt.edu; marcjkim@vt.edu; kramu@vt.edu). The cost of this converter is significantly lower due to the
S.-G. Oh is with the Department of Mechatronics Engineering, Jinju National reduction of attendant circuits such as gate drives, logic power
University, Jinju 660-758, Korea (e-mail: sgoh@inju.ac.kr). supplies, and heat sinks. However, it has the disadvantage of
Color versions of one or more of the figures in this paper are available online
at http://ieeexplore.ieee.org low-performance since the main phase winding is controlled
Digital Object Identifier 10.1109/TIA.2007.895744 using the single controllable switch, and the auxiliary winding
TABLE I
COMPARISON OF CONVERTER LOSSES BETWEEN THE DIFFERENT CONVERTER TOPOLOGIES FOR TWO-PHASE SRM
increasing the inductance until the uniform air gap generates in [7]. The device switching loss is determined by the maximum
inductance up to the maximum. These two different air gaps voltage and current stress, and the device conduction loss is
make this motor produce the continuous torque at any rotor determined by the average current and forward voltage drop
position. Another feature is the normal forces that pull in three from the datasheet under the assumption of the same conditions
different directions and prevent ovalization of the stator in two of control scheme, switching parameters, and torque-speed
directions and, hence, in the mitigation of stator acceleration operation.
that invariably leads to reduced acoustic noise. There is no flux For easier comparison between the different converters, nor-
reversal in any part of the stator, and only two thirds of the malized power loss is used by setting the discrete insulated-
stator back iron is used. Both of these facts result in lower gate-bipolar-transistor (IGBT) switching loss 1 p.u. In the case
core losses. of hard chopping in the asymmetric converter, the total IGBT
switching loss is 4 p.u. since it has four switches for a two-
phase SRM. The rationale is applied to estimate the power
III. C OMPARISON OF THE C ONSIDERED C ONVERTER
loss for the remaining converters. Note that all other converters
Converter design has been one of the main research aspects also have 4-p.u. total IGBT loss. The reason is as follows:
of SRM drives since performance and cost of the drive are The N + 1 has three switches, and switch T3 in Fig. 1(d) has
highly affected by the converter configurations. A number twice the device switching losses due to the repeated switching
of converter topologies suitable for SRM drives have been operation for every phase. The split dc and split ac converters
proposed, implemented, and characterized in literature [1], [2] have half the number of switches when compared to the asym-
to facilitate the selection of a proper topology for the given metric converter, hence, the voltage and current stresses seen
applications. There are several methodologies for converter by the switch are [Vdc , 2I] and [2Vdc , I], respectively. Hence,
classification, but all of them give way to the classification they have the same converter rating (4V I) as the asymmetric
by the number of power switching devices. Due to the high converter, resulting in the same total per-unit switching loss
cost of power semiconductors and their drive circuits relative (4 p.u.). The single controllable converter also has a 4V I rating
to other components in the SRM drive, a large amount of because of its voltage (2 V) and current (2I) stress, thus, having
effort has gone into developing the SRM drive converters which the same total IGBT switching loss (4 p.u).
utilize the fewest possible number of power switches. Among The per-unit conduction loss of the discrete IGBT and diode
many converter topologies, five types of configurations, which can be determined by the measured average current and ON-
are shown in Fig. 1, have been found to be feasible for the state voltage drop from the device datasheet and was found
considered two-phase SRM drive. In this section, both qual- to be 1.33 and 0.99 p.u., respectively, when compared to the
itative and quantitative comparisons are presented to find the discrete IGBT switching loss (1 p.u.). Thus, the total IGBT
most appropriate converter configuration in terms of converter and diode conduction losses in the asymmetric converter under
efficiency, cost, and performance. hard chopping are 5.3 and 3.96 p.u., respectively. In the soft
The volt–ampere (VA) rating of the converter is important chopping mode, the IGBT switching loss decreases due to the
because it provides a useful measure of the actual power rating reduced number of switching devices, and the IGBT conduc-
of the semiconductor switches that reflects drive cost. The per- tion loss increases to 1.98 p.u. Table I shows the comparison
unit voltage stress (V ) times per-unit current stress (I) that is of the total converter losses between the different converter
multiplied by the number of total power switches (N ) in the topologies based on the discrete per-unit loss. Likewise, the
converter gives the converter VA rating (N × V × I). Based on total IGBT and diode conduction losses for all converters can
this VA rating, the relative converter efficiency can be evaluated be determined.
by comparing the converter power losses among each different Table I shows the split ac converter that has the lowest power
configuration. losses resulting in the highest converter efficiency due to its
The converter power losses can be estimated from each smaller VA rating and fewer number of power switches than
device switching and conduction losses by using the derivation any other converter.
706 IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, VOL. 43, NO. 3, MAY/JUNE 2007
TABLE II
OVERALL COMPARISON BETWEEN THE DIFFERENT CONVERTER TOPOLOGIES FOR TWO-PHASE SRM
Another important factor for selecting the converter topol- reliability, it has been chosen for performance comparison with
ogy is overall drive cost which is mainly determined by the the split ac converter.
number of power semiconductors, isolated gate drivers, passive
components, sensors, and control circuits. Table II shows the
IV. C ONVERTER S TRUCTURE
overall comparison of the considered split ac converter with
the other converters in terms of performance, component count, The split ac converter uses a single-switch per phase. Phase A
efficiency, and cost. is energized by turning ON switch T 1. The current can be
One of the key components other than power switching circulated through T1, phase A, and capacitor C1. When T1 is
devices that affect the overall drive cost is the dc capacitor. turned OFF, the current will continue to flow through phase A,
As shown in Table II and Fig. 1, the split ac and dc converters capacitor C2, and diode D1 . In the same mode, capacitor C2 is
require two dc-link capacitors each, and the single controllable charged, and the stored energy in phase A is depleted quickly.
switch converter also requires two capacitors; one for the dc C2 would be further recharged by the ac supply if the ac
link and the other for the energy recovery. Therefore, the cost of supply voltage were able to forward the bias diode D2. Similar
the split dc and ac converters could double due to the additional operation follows for the excitation and the commutation of
cost of the dc-link capacitors. The increased current-ripple phase B. The phase voltage is Vdc when T 1 is ON, and when it is
rating increases the capacitance requirement which adds cost turned OFF with a current present in phase A, the phase voltage
to the overall drive. is −Vdc . Therefore, the voltage available to energize and de-
However, the price reduction that is obtained by the reduced energize the phase windings is two times greater than the split
number of power semiconductor devices and their gate-drive dc supply converter. The energy transferring from one phase
circuits still keeps the overall drive cost of the split dc and ac winding during the turn-OFF instant of current control and
converters lower than the conventional asymmetric converter. commutation provides the energy to force the current through
Employing appropriate control algorithms to minimize the cur- the next phase winding. Instead of the two low-capacitance
rent ripple can reduce the capacitor size [8]. When comparing film capacitors [8], two electrolytic capacitors are used in order
the split ac and dc converters, the cost of the split ac is lower to maintain the stable dc-link voltage and provide a sufficient
due to its lowest number of rectifier diodes. positive torque under the full load condition and low-speed
Although the single controllable switch converter is the operation.
least expensive, it is not desirable for our considered drive
system due to its low performance and efficiency. The split
V. C ONTROLLER S TRUCTURE
ac converter has the same power rating as the asymmetric
converter but utilizes fewer components, and the total converter A block diagram of the drive-system control is shown in
loss is the lowest among all the converters, thus, making the Fig. 3. Position feedback is needed to synchronize the current
split ac converter the most inexpensive and highly efficient flow, with respect to the rotor position, in order to generate the
configuration. desired motoring torque. It is also required to compute the rotor
The classic asymmetric converter is less competitive because angular velocity, which is compared with the desired velocity.
of its higher cost; however, due to its high performance and The soft start block receives the velocity commands at startup
HA et al.: DESIGN AND DEVELOPMENT OF LOW-COST AND HIGH-EFFICIENCY VARIABLE-SPEED DRIVE SYSTEM 707
and applies the necessary sequence of commands to each modeling procedure given in [3] was used. From finite element
control loop to achieve the new target velocity. After SRM has analysis of the motor, discrete data sets of 3-D relationships
settled to a new target speed, the soft start loop is encountering between inductance versus current versus position and torque
its wait state. In this state, it continuously checks if a new target versus current versus position can be obtained. By using the
velocity has arrived at the analog-to-digital-converter channel. cubic spline interpolation, the flux linkages and the electro-
If a new target speed arrives, the soft start loop shifts into its magnetic torque for any rotor position and excitation current
soft start state. Depending upon whether the new target velocity can be retrieved [3]. Voltage drops and switching transients of
is above or below the current velocity, the soft start loop will the power electronic devices are negligible compared to the
either increment or decrement the current velocity command dc-link voltage and mechanical time constant of the motor;
by 1 r/min every 1 ms. A closed loop velocity controller with a therefore, the switching devices are assumed to be ideal. The
PI control law determines the torque required to bring the motor following system equations combining the converter and motor
velocity to the command value at a certain load. A commutation are derived for each mode of operation that corresponds with
algorithm determines the excitation and commutation logic the IGBT switching modes.
with respect to the present velocity, and the torque command
is eventually converted into a set of phase current commands. T1: ON (phase A is energized)
The current in an SRM phase winding is directly measured with
a current sensor. The measured current is compared with the
current command, forming an error signal. The current error is νa = νc1
compensated via a PI control law and an appropriate pulsewidth
modulation (PWM) control action is taken. dλa
= Ra ia +
As shown in Fig. 4, the commutation control, the current dt
command generator, and the current control loop are executed
at 10 kHz. Because of their lower bandwidth requirements, the dia dLa (θ, ia )
= Ra ia + La (θ, ia ) + ia ω (1)
velocity control loop is performed at 1 kHz. dt dθ
1
VI. S IMULATIONS νc1 = ic1 dt + νc1 (tOFF ), ic1 = −ia (2)
C1
In order to verify the feasibility of the drive system, it was
modeled, simulated, and analyzed. For the controller, a standard λa = La (θ, ia ). (3)
708 IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, VOL. 43, NO. 3, MAY/JUNE 2007
Fig. 5. Simulation of the split ac drive system (scale: Voltage = 200 v/div, current = 10 A/div, and torque = 5 N · m/div).
νa = −νc2
dλa
= Ra ia +
dt
dia dLa (θ, ia )
= Ra ia + La (θ, ia ) + ia ω (4)
dt dθ
1
νc2 = ic2 dt + νc2 (tON ), ic2 = ia . (5)
C2
where ia , ic1 , and ic2 are the phase A, capacitor C1, and capac-
itor C2 current, respectively; νa , νc1 , and νc2 are phase A, ca- Fig. 6. Operation of the split ac drive system (scale: Phase voltage and capac-
pacitor C1, and capacitor C2 voltage, respectively. νc1 (tOFF ) itor voltage = 100 v/div, phase current = 5 A/div, and time = 2 ms/div).
is the capacitor C1 voltage at the last time during turn OFF T 1,
and νc2 (tON ) is the capacitor C2 voltage at the last time during current is 12 A during the conduction region, and the ripple
turn ON T 1. Ra , La , and λa are phase A winding resistance, in- voltage of the capacitor is 28 V because chopping one phase
ductance, and flux linkages, respectively. The system equations continuously charged the opposite capacitor. It was caused by
for phase B can be derived similarly. The motor speed dynamic the phase energy transfer from the conducting phase to the
equation is given as capacitor during switch turn OFF.
dωm
J + Bωm = Te − Tl (6) B. Efficiency
dt
1) Experimental Setup and Measurements: In order to val-
where ωm , J, and B are the rotor speed, the rotor inertia, and
idate the considered drive system, comprehensive sets of ex-
the friction coefficient, respectively. Te is the electromagnetic
periments were performed. The control algorithm mentioned in
torque obtained from motor magnetic characteristics as a func-
Section V was implemented in a 16-b DSP controller, Texas
tion of the current and rotor position, and Tl is the load torque.
Instrument’s TMS320LF2808. Current sensing and feedback
Fig. 5 shows the simulation results for operation at 3000 r/min
was performed using the LA25-NP current transducers man-
under a load of 4.5 N · m. The upper and lower dc-link capacitor
ufactured by LEM, Inc. In order to protect the control circuitry,
voltages, phase A and B currents, as well as the corresponding
all switches were driven using the optoisolating gate drivers to
electromagnetic torque, are plotted. The voltage to the phase
produce a +15-V gate signal with complete galvanic isolation.
winding is applied in advance by 6◦ , and the current turn OFF is
It is controlled in the way that the same advanced and conduc-
initiated 30◦ in advance.
tion angles are used in the considered split ac drive system and
the asymmetric drive system in order to compare the efficiency
VII. E XPERIMENTAL R ESULTS and the acoustic noise level.
The considered split ac drive system and the asymmetric
A. Operation of the Split AC Drive System
drive system have been tested on a 2.2-hp 3000-r/min two-
The operation of the considered drive system at the rated phase SRM with dc generator as its load shown in Fig. 7.
speed and the full load is shown in Fig. 6. Average phase The voltage and current can be measured using a differential
HA et al.: DESIGN AND DEVELOPMENT OF LOW-COST AND HIGH-EFFICIENCY VARIABLE-SPEED DRIVE SYSTEM 709
TABLE IV
DRIVE CONVERTER EFFICIENCY AT VARIOUS LOADS (3000 r/min)
TABLE III
RECTIFIER EFFICIENCY AT VARIOUS LOADS (3000 r/min) TABLE V
MACHINE EFFICIENCY AT VARIOUS LOADS (3000 r/min)
TABLE VII
MEASURED SOUND-PRESSURE LEVEL (NO LOAD)
Fig. 9. Frequency spectrum of acoustic noise at the split ac drive system while driving at 3000 r/min and the full load.
Fig. 10. Frequency spectrum of acoustic noise at the asymmetric drive system while driving at 3000 r/min and the full load.
phase having comparable efficiency and acoustic noise level as accurate copper losses in the dc generator. Improper value of
an asymmetric drive system under full load. resistance can lead to the reduction of the input power of dc
generator, resulting in the reduction of the output of the tested
A PPENDIX drive system. Temperature measurements are made right after
C ALCULATION OF THE O UTPUT P OWER OF SRM driving, and resistor values for copper at any temperature other
than the standard temperature (usually specified at 20 ◦ C) are
The losses of dc generator, including the copper losses,
measured through the following formula [11]:
mechanical losses, core losses, stray losses, and brush contact
losses, can be calculated in advance, and based on these losses,
the output power of SRM can be calculated. R = Rref [1 + α · (T − Tref )] (9)
1) Copper Losses (in Case of Separately Excited Field):
Pcopper = Ia2 · Ra . (8) where R is the resistance at temperature T , Rref is the re-
sistance at reference temperature Tref , α is 0.004041, which
The change in resistance of the armature due to temperature means the temperature coefficient of resistance for copper, and
and skin effect has to be considered in order to calculate the T is temperature in degree Celsius. Skin effect can be neglected
712 IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, VOL. 43, NO. 3, MAY/JUNE 2007
Fig. 11. Circuitry for measuring mechanical and core losses. 7) Rectifier Efficiency: It can be found from Fig. 7 that the
rectifier efficiency is given as
since the frequency of dc generator at the rated speed is 100 Hz,
and the ac/dc resistance ratio is unity. Pin,dc
ηrec = . (16)
2) Mechanical Losses and Core Losses: These two losses Pin,sys
can be calculated while driving a dc generator as a dc motor at
8) Converter Efficiency: It can be found from Fig. 7 that the
no load. The output power of dc motor is ideally zero, and all
converter efficiency is given as
of the input power turn into losses (Fig. 11).
The copper losses in the field and the armature circuits at no
Pin,SRM
load are given as ηconv = . (17)
Pin,dc
Pcopper,m = If,m
2
· Rf + Ia,m
2
· Ra . (10)
9) Machine Efficiency: It can be found from Fig. 7 that the
machine efficiency is given as
The remaining portion of the input power must be rotational
losses of the motor, which is the summation of mechanical Pout,SRM
losses and core losses. Hence, the rotational losses with respect ηSRM = . (18)
Pin,SRM
to speed are expressed as
10) System Efficiency: It can be found from Fig. 7 that the
Pmech + Pcore = Pin,m − Pcopper,m overall system efficiency is given as
[9] S. J. Yang, Low-Noise Electrical Motors. Oxford, U.K.: Clarendon, R. Krishnan (S’81–M’82–SM’95–F’01) received
1981. the Ph.D. degree in electrical engineering from
[10] P. Vijayraghavan and R. Krishnan, “Noise in electric machines: Concordia University, Montreal, QC, Canada.
A review,” IEEE Trans. Ind. Appl., vol. 35, no. 5, pp. 1007–1013, He is a Professor of electrical and computer en-
Sep./Oct. 1999. gineering at Virginia Polytechnic Institute and State
[11] T. R. Kuphaldt, All about Circuits—Chapter 12. The physics of conductors University, Blacksburg. His research interests are
and insulators—Temperature coefficient of resistance, vol. 1-DC, 2003. analysis, design and innovations in electric motor
[Online]. Available: www.Allaboutcircuts.com drives, electric machines, and power converters for
[12] G. R. Slemon and A. Straughen, Electric Machines. Reading, MA: motor drives and applied control. He is the author
Addison-Wesley, 1980. of Electric Motor Drives (Prentice Hall, Feb. 2001),
its Chinese translation (Pearson Education Taiwan,
2002), Indian Edition (Prentice Hall of India, 2002), and International Edition
Keunsoo Ha (S’04) was born in Seoul, Korea, on (Prentice Hall International Edition, 2001), and the author of Switched Reluc-
February 25, 1970. He received the B.S. and M.S. tance Motor Drives (CRC Press, June 2001) (first edition) and 2003 (second
degrees in electrical and control engineering from edition), and Coeditor of Control in Power Electronics (Academic Press, Aug.
Hong-Ik University, Seoul, Korea, in 1993 and 1995, 2002). He directs the Center for Rapid Transit Systems pursuing unique, safe,
respectively. He is currently working toward the high-speed, energy efficient, and personal electric transit solutions. He has
Ph.D. degree at Virginia Polytechnic Institute and been a Consultant for more than 18 companies in USA. He has developed
State University, Blacksburg. and delivered short courses for industry on vector-controlled induction motor
In 1995, he worked with the Precision Machinery drives, permanent magnet synchronous and brushless dc motor drives, switched
Research Center, Korea Electronics Technology In- reluctance motor (SRM) drives, and linear electric motor drives. His inventions
stitute, where he had been a Senior Researcher for constituted the founding technologies for two start-up companies in the U.S. in
two years and researched in developing the brushless linear and rotating SRM drives technologies, respectively. Apart from founding
dc motor drives for household air-conditioners and refrigerator’s fan and step these companies, he served as the founding Chief Technical Officer for some
motor controllers for car dashboard and linear motor drivers for machine tools. time to both. He has been granted three U.S. patents, and many are pending
His research interests include electric motor drives and power electronics, and in U.S., Europe, and other countries. His inventions have been prominently
his principal research concerns the sensorless control of switched reluctance featured in public media, including radio, TV, and newspapers such as The Wall
motor. Street Journal.
Mr. Ha was the recipient of the Third Paper Prize Award from the Industrial Mr. Krishnan was the recipient of Four Best Paper Prize Awards from IEEE
Drives Committee of the IEEE Industry Applications Society. Industry Applications Society Industrial Drives committee. His coedited book
Control in Power Electronics won the Best Book Award from Ministry of
Education and Sport, Poland, in 2003. In addition, he received the first prize
from the IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS for his paper.
He is a Fellow of the IEEE cited for his contributions to the development of
Cheewoo Lee (S’05) was born in Busan, Korea, ac and SRM drives. He was also the recipient of IEEE Industrial Electronics
in 1972. He received the B.S. and M.S. degrees in Society’s Dr. Eugene-Mittelmann Achievement Award for Outstanding Techni-
electrical engineering from Pusan National Univer- cal Contributions to the Field of Industrial Electronics. He is a Distinguished
sity, Pusan, Korea, in 1996 and 1998, respectively. Lecturer of IEEE Industrial Electronics Society. He is an elected Senior AdCom
He is currently working toward the Ph.D. degree at Member of IEEE Industrial Electronics Society and served as Vice President
Virginia Polytechnic Institute and State University, (publications) from 2002 to 2005. He served as the General Chair of the 2003
Blacksburg. IEEE Industrial Electronics Conference, Roanoke, VA, and as one of the three
In 1998, he was with the Digital Appliance Com- General Co-Chairs of the IEEE Industrial Electronics Society International
pany of LG Electronics Inc., where he had been Conference on Industrial Technology 2006 in Mumbai, India.
a Senior Research Engineer since 2002 and has
conducted research on the development of Induction
Motors, SynRMs, and brushless dc motors for a compressor in home-appliance
air conditioners and refrigerators. His research interests include controllable
electric motor drives and their optimal control using a DSP.