Design Sheet

Load calculation Table 1) based on actual connected load load type Load type
light/ fans/ computer

KW load

nominal daily duty cycle Load Duty factor system hrs/day voltage

amp-hr load ah/day

peak current draw

AC

45700

6 1 Total amp-hr load per system

240

1142.5 190.4167 1142.5

2) based on energy consumption reading of electricity bill


energy energy energy demand demand Apr demand Jan July to sept to June to March energy demand energy demand nominal Oct to from the system system December per day voltage Amp- Hr load per day

240

load type Load type


light/ fans/ computer

KW load

nominal system peak current voltage draw

AC Tilt at Latitude (-) 15 deg

240

0
Tilt at Latitude amp -hr load per day 1142.5 1142.5 1142.5 1142.5 Peak Sun (Hrs per day) Design current 5.51 5.93 5.77 5.31 4.41 3.98 3.98 4.14 4.1 4.8 5.24 5.53 3.98 207.3502722 192.6644182 198.0069324 215.1600753 259.0702948 287.0603015 287.0603015 275.9661836 278.6585366 238.0208333 218.0343511 206.6003617 287.0603015

Month
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

amp -hr load per day 1142.5 1142.5 1142.5 1142.5

Peak Sun (Hrs per day) Design current 4.79 5.4 5.59 5.41 4.65 4.22 4.21 4.28 4.1 4.53 4.64 4.72 4.1 238.5177453 211.5740741 204.3828265 211.1829945 245.6989247 270.7345972 271.3776722 266.9392523 278.6585366 252.2075055 246.2284483 242.0550847 278.6585366

1142.5
1142.5 1142.5 1142.5 1142.5 1142.5 1142.5 1142.5 Acceptable Value

1142.5
1142.5 1142.5 1142.5 1142.5 1142.5 1142.5 1142.5

Tlt at latitude + 15 deg

amp -hr load per day 1142.5 1142.5 1142.5 1142.5

Peak Sun (Hrs per day)

Design current

1142.5
1142.5 1142.5 1142.5 1142.5 1142.5 1142.5 1142.5

5.91 6.15 5.66 4.95 3.99 3.57 3.59 3.83 3.93 4.83 5.54 6.02

193.3164129 185.7723577 201.8551237 230.8080808 286.3408521 320.0280112 318.2451253 298.3028721 290.7124682 236.5424431 206.2274368 189.7840532
320.0280112

Acceptable Value 3.57 data source : Atmospheric science data center NASA Design current = yrly average Peak Sun = Optimal Tilt angle for fixed array = Optimal Tilt angle for manual adjustable =

287.0603015 4.89 25 oct to april = 39 deg may to sept= 9 degree

calculate the size of the battery needed for the PV system


adjusted Amp- Hr load per day

autonomy Max depth of days discharge 1 0.8

T-factor derate for temp 1

Reqd battery battery in capacity parallel 0

batteris in series 120

total batteries 0

1215

battery information make model type tubular LMLA @C10 ECV 1.75 15 hrs discharge rate Rated capacity @ C10 nominal voltage 2 rated capacity 1500

battery bank information


No of batteries batteries in series batteries in parallel Max permissible DOD battery bank voltage battery bank capacity @C10 discharge current

0 120 0 80% 240 0

SYSTEM ARRAY SIZE


Design current 287.0603 module derate factor derated design current #DIV/0! rated module current 0 modules in parallel #DIV/0!

nominal battery voltage 2.4

batteries in series

highest required load temp. voltage module voltage 288 0

modules in series

modules total in parallel modules

120

#DIV/0!

#DIV/0!

#DIV/0!

rated modules module in parallel current @40C

rated array current 0 #DIV/0!

PV MODULE INFORMATION
make / model weight dimensio n At STC Nominal volt Thickness bypass diode Y / N Open circuit At highest expected temp 40C rated modules module in series voltage @ 40C open ckt module voltage @ 40C #DIV/0! module short ckt current@ 40C

array short ckt current 0 #DIV/0!

voltage

rated array voltage 0 #DIV/0! array open ckt voltage 0 #DIV/0!

current

At STC

short circuit

#DIV/0!

HYBRID INDICATOR
corected AH load/ day #REF! nominal sys voltage #REF! watt-hr load conversion factor 365 Annual KWH load #REF!

#REF!

derated design current

nominal sys voltage

designed array power

watt-Hr load Array to load per day ratio #DIV/0!

Hybrid / standalone ?

Assumptions :
Battery efficiency Annual average sunshine/day Invertor efficiency Derating of module o/p Aging factor design margin other losses battery charging time

1.25 1.1

BOS Worksheet
CONTROLLER SPECIFICATION Array short ckt Min. controller current 0 Specification Make/model Rated voltage Rated current Features temperature compensation Reverse current Protection Rated controller current controllers in parallel #DIV/0! Adjustable set points High voltage disconnect high voltage reconnect Low voltage disconnect low voltage reconnect Metres Battery voltage Array Current load current

Power Conditioning Unit Specification System Requirement Wave form DC system voltage AC system voltage Surge capacity

Inverter specification Make / model waveform desired Input DC voltage Output AC voltage

Total AC watts cargamaximum sendlla dec.a maximum simultaneous AC Load Inverter run time at maximum sumultaneous AC load Continuous Duty Rating of inverter Required inverter efficiency

Surge Capacity Features Battery charging Voltmeter Remote control Generator starting Power transfer switch Maximum power tracking

Converter system requirement Tension de entrada de cc. Tension de salda de cc. Maxima potenda de salda Temperature de fundonamlento

converter specification Make / model Input voltage Output voltage Output current required Operating temparature Features Adjustable output voltage

DC WIRE SPECIFICATION allowanc e for temp. derate wire size

system Wire runs voltage modue to module D1 array to co ntroller D2 battery to battery D3 Batter to Dc loads D4 Battery charger to battery D5

Maximum current

allowed volt one way age drop length

wire type
Pvc insulated FR Cu coductor Pvc insulated FR Cu coductor Pvc insulated FR Cu coductor Pvc insulated FR Cu coductor Pvc insulated FR Cu coductor

battery to inverter/co nvertor D6 system grounding Equipment ground system

Pvc insulated FR Cu coductor

wire type GI strip GI strip AC WIRE SPECIFICATION

size 35mmx6 mm 35mmx6 mm

type of earth ground GI plate earthing GI plate earthing

system Wire runs voltage Inverter to Ac distribu tion panel D7 Branch ckt 1 Branch ckt 2 Branch ckt 3 Branch ckt 4 Branch ckt 5 generator to battery charger D8 generator to AC load panel D9 system grounding Equipment ground system

Maximum current

allowed volt one way age drop length

allowanc e for temp. derate wire size

wire type

wire type GI strip GI strip

size 35mmx6 mm 35mmx6 mm

type of earth ground GI plate earthing GI plate earthing

circuits switch D1 D2 D3 D4 D5 D6 D7 D8 diode

switches & protection Components rated protection device current fuse surge

rated voltage

descriptio n

D9

Bill of Materials
sl no description 1 Module ploycrystalline 5 module mounting MS 2 structure- galvanized 3 Array junction box 4 Main junction box make moser baer or equivalent reputed make hensel/ trinity/ equivalent make hensel/ trinity/ equivalent make unit nos nos nos nos quantity

5 1 core 4.0 mm Cu cable 6 7 2 core 10 mm Cu armoured cable 3 & core 25 mm Cu


armoured cable

havels/finolex or equvalent havels/finolex or equvalent havels/finolex or equvalent havels/finolex or equvalent

mtrs mtrs mtrs mtrs

8 1 core 25 mm Cu cable PCU 50 KWp MPPT 9 charger battery bank 240V, 10 1400Ah@C10 11 AC Distribution Board 12 Lighting Arrestor & over voltage protection

OPS/PPS/Agni or equivalent nos HBL/ luninux/ exide or nos equivalent Havels/ legrand or equivalent nos set Ibex or equivalent set

13 Earthing Protection Kits

14 Danger notice plate LS local Plant control,data logger 15 & monitoring system OPS/PPS/Agni or equivalent set with PC 16 tools and tackles set reputed make 17 Insulation mat 18 electrical assories n reputed make LS set

18

K factor and T-Factor manufacturer manual Ah= IDCXK-factorXdesign marginXT-factorXageing factor IDC= KVAx load Power factorx 1000/ system Dc voltage IDC= KVAx load Power factorx 1000/ end cell voltage xno.of cellsx inverter efficiency

Hybrid PV system design consideration days of derate for hybrid Corected maximum autonom temperat battery AH load DOD y ure capacity peak current draw Min battery battery discharg charge e time rate

Nominal sys voltage

nominal battery grid/gen charging chargery derate power efficiency factor

hybrid load load generator array to provided provided size load ratio by array by utility

annual KWH load

annual load from grid

Hybrid battery bank & PVmodule sizing hybrid watt hr array to load per load ratio day hybrid array power nominal system voltage rated module current nominal modules module in parallel voltage

modules in series

total modules

hybrid battery capacity

capacity of selected battery

hybrid nominal batteries system in parallel voltage

nominal battery voltage

hybrid total capacity batteries hybrid of hybrid in parallel batteries bank

Usable Max DOD battery capacity