Sie sind auf Seite 1von 1

Pipeline Wall Thickness Calculation as per CSA Z662 Section 4.3.3.1.

1 P=(2*S*t)/D*F*L*J*T Cells for normal input data are highlighted: Cells for infrequent input data are highlighted: Cells containing equations are highlighted: Cells used for checking are highlighted:

Check CSA Z662 Section 4.3.3 4.3.3.2 Table 4.2 Table 4.3 Table 4.4 Table 4.5 Design Location Joint Temp. Selected Design Calculated Pressure OD OD SMYS SMYS Factor Factor Factor Factor wt ID wt wt P D S F L J T t kPa in mm psi mPa mm mm in mm 9930 16 406.4 65000 448.2 0.8 1 1 0.97 5.80 394.8 0.228 6.35 0 0.0 0 0.0 0.000 0 0.0 0 0.0 0.000 0 0.0 0 0.0 0.000 0 0.0 0 0.0 0.000 0 0.0 0 0.0 0.000 0 0.0 0 0.0 0.000

<120 wt ID Selected Hoop stress % SMYS kPa 317760 0 0 0 0 0 0 D/t Check Selected for Stress OK Too Thin Too Thin Too Thin Too Thin Too Thin Too Thin Check Selected for D/t OK OK OK OK OK OK OK

in mm 0.250 393.7 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0

% Ratio 70.90% 64 0.00% 0 0.00% 0 0.00% 0 0.00% 0 0.00% 0 0.00% 0